0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
FIREDAM-SPRAY-5GAL

FIREDAM-SPRAY-5GAL

  • 厂商:

    3M

  • 封装:

  • 描述:

    FIREDAM SPRAY 200, RED, 5 GA

  • 数据手册
  • 价格&库存
FIREDAM-SPRAY-5GAL 数据手册
3M™ FireDam™ Spray 200 Product Data Sheet 4 HOUR UP TO SMOKE SEAL L RATED FIRE BARRIER Fire Protection Meets Optional L Requirements SOUND BARRIER ELASTOMERIC STC 56 In STC 56-rated wall assembly 1. Product Description ±50% Movement Capability 3M™ FireDam™ Spray 200 is a sprayable material that dries to form a tough, elastomeric coating. This material is used to firestop perimeter joints (curtain wall), construction joints and through penetration openings. 3M™ FireDam™ Spray 200,when installed prop-erly, will help control the transmission of fire, heat, and smoke before, during, and after exposure to fire. Available in: • • • Sag-resistant, highly elastomeric formula for construction joints (airless sprayer sold separately) . • • Gray Product Features FILL, VOID, OR CAVITY 90G9 Red. Up to 4-hour fire protection in construction joints per ASTM E 1966 (UL 2079) Up to 2-hour fire protection for through penetration systems per ASTM E 814 (UL 1479) & CAN/ULC-S115 Highly elastic material maintains performance with up to ± 50% movement capabilities Helps minimize sound transfer* Broad range of applications (extensive portfolio of tested and listed building and perimeter joint systems) • • • • • • Improved spraying pattern – applied with conventional airless spray equipment Robust jobsite formula (freeze/thaw resistant and uniform seal formation in hot or cold drying conditions) Improved spraying for lower sag, uniform coating build properties (stays where it’s sprayed) Improved hiding power to maintain proper coating thickness Paintable Easy clean up FILL, VOID OR CAVITY MATERIAL FOR USE IN JOINT SYSTEMS, THROUGH-PENETRATION FIRESTOP SYSTEMS, AND PERIMETER CONTAINMENT SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 90G9 FIRESTOP SYSTEMS SEE INTERTEK DIRECTORY Meets the intent of LEED® VOC guidelines—helps reduce the quantity of indoor air contaminants that may be odorous, irritating and harmful to the comfort and well-being of the installers and occupants. *Minimizes noise transfer—STC-Rating of 56 when tested in STC 56-rated wall assembly. FIRESTOP SYSTEMS SEE INTERTEK DIRECTORY SUBJECT TO THE CONDITIONS OF APPROVAL AS A WALL & FLOOR PENETRATIONFIRESTOP WHEN INSTALLED AS DESCRIBED IN THE CURRENT EDITION OF THE FMRC APPROVAL GUIDE 2. Applications 3M™ FireDam™ Spray 200 is ideal for sealing perimeter joints (curtain walls), construction joints and through penetrations. Recommended for firestopping areas that require large coverage. Helps limit the spread of noxious gas and smoke. Helps maintain the integrity of fire-rated construction. Note: when tested at 50% movement for 100 cycles in a 4-inch joint, product remained elastomeric and did not show signs of cracking. 3M™ FireDam™ Spray 200 has been qualified for use as a replacement or repair material in all listed systems that specify its predecessor, 3M™ FireDam™ Spray 100. 3. Specifications This coating is tested and listed by independent test agencies such as UL, ULC, Intertek. In addition, the coating has Factory Mutual approval. The coating complies with the current requirements of the International Building Code (IBC), NBCC, NFPA 5000 and NFPA 101. Construction Joints: Has been fire tested and evaluated under the pass/fail criteria of ASTM E 1966 (UL 2079) and CAN/ULC-S115 at the maximum extended joint width. Perimeter Joints: Has been fire tested and evaluated under the pass/fail criteria of ASTM E 2307 and CAN/ULC-S115 at the maximum extended joint width. Through Penetrations: Has been fire tested and evaluated under the pass/fail criteria of ASTM E 814 (UL 1479) Standard and CAN/ULC-S115. For technical support relating to 3M Fire Protection Products and Systems, call: 1-800-328-1687 For more information on 3M Fire Protection Products, visit: www.3m.com/firestop Typically Specified Division Division 7 Section 07 84 00 – Firestopping Section 07 84 13 – Penetration Firestopping Section 07 84 16 – Annular Space Protection Section 07 84 43 – Fire Resistive Joint Sealants Section 07 85 53 – Building Perimeter Firestopping Section 07 86 00 – Smoke Seals Section 07 92 13 – Elastomeric Joint Sealants Section 07 92 19 – Acoustical Joint Sealants 4. Performance & Typical Physical Properties Colors Available: Non-Volatile Content: Coverage*: Flash Point: ASTM E 84: Dry Time: STC Rating: Gray or Red Unit/vol: 5 Gallon (18.9 liter) pail / 1155.0 cu. in. (18926.9 cu. cm.) 65% Viscosity: 120,000 cps with shear thinning 12.8 sq. ft./gallon (0.31sq. m/liter) *calculated coverage based on 1/8 in. (3 mm) thick wet coating None Flame Spread
FIREDAM-SPRAY-5GAL 价格&库存

很抱歉,暂时无法提供与“FIREDAM-SPRAY-5GAL”相匹配的价格&库存,您可以联系我们找货

免费人工找货