0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ESTW010A0A41-HZ

ESTW010A0A41-HZ

  • 厂商:

    ABB

  • 封装:

    DIP8 模块,1/8砖

  • 描述:

    隔离模块 直流转换器 1 输出 5V 10A 36V - 75V 输入

  • 数据手册
  • 价格&库存
ESTW010A0A41-HZ 数据手册
GE Data Sheet ESTW010A0A Series (Eighth-Brick) DC-DC Converter Power Modules 36–75Vdc Input; 5.0Vdc Output; 10A Output Current STINGRAY™ SERIES RoHS Compliant Applications Features  Wide input voltage range: 36-75 Vdc  Monotonic startup into prebiased load  Output Voltage adjust: 80% to 110% of Vo,nom  Remote sense  Constant switching frequency  Positive remote On/Off logic  Input under/over voltage protection  Output overcurrent and overvoltage protection  Over-temperature protection  Industry standard, DOSA compliant footprint  57.9mm x 22.8mm x 8.5mm  (2.28 in x 0.9 in x 0.335 in)  Distributed Power Architectures  Low profile height and reduced component skyline  Wireless Networks   Access and Optical Network Equipment Suitable for cold wall cooling using suitable Gap Pad applied directly to top side of module  Industrial Equipment  High efficiency: 91%  No thermal derating up to 80 °C, 1.0m/s (200 LFM)  Wide operating temperature range (-40°C to 85°C)  Compliant to RoHS EU Directive 2011/65/EU & REACH Directive (EC) No. 1907/2006  UL* 60950-1, 2nd Ed. Recognized, CSA† C22.2 No. 60950 107 Certified, and VDE‡ (EN60950-1, 2nd Ed.) Licensed  CE mark meets 2014/35/EU directive§  Meets the voltage and current requirements for ETSI 300132-2 and complies with and licensed for Basic insulation rating per EN60950-1  2250 Vdc Isolation tested in compliance with IEEE 802.3¤ PoE standards  ISO**9001 and ISO 14001 certified manufacturing facilities Options  Negative Remote On/Off logic (preferred)  Over current/Over temperature/Over voltage protections (Auto-restart) (preferred)  Heat plate version (-H)  RoHS 6/6 compliant; Lead Free (-Z)  For additional options, see Table 2 (Device Options) under “Ordering Information” section. Description The ESTW010A0A, Eighth-brick low-height power module is an isolated dc-dc converter that can deliver up to 10A of output current and provide a precisely regulated output voltage of 5.0V over a wide range of input voltages (VIN = 36 - 75Vdc). The modules achieve typical full load efficiency of 91%. The open frame modules construction, available in through-hole packaging, enable designers to develop cost and space efficient solutions. * UL is a registered trademark of Underwriters Laboratories, Inc. † CSA is a registered trademark of Canadian Standards Association. ‡ VDE is a trademark of Verband Deutscher Elektrotechniker e.V. § This product is intended for integration into end-user equipment . All of the required procedures of end-use equipment should be followed. ¤ IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Incorporated. ** ISO is a registered trademark of the International Organization of Standards October 30, 2019 ©2016 General Electric Company. All rights reserved. GE Data Sheet ESTW010A0A Series Eighth-Brick Power Modules 36–75Vdc Input; 5.0Vdc Output; 10A Output Current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage Continuous All VIN -0.3 80 Vdc Transient, operational (≤100 ms) All VIN,trans -0.3 100 Vdc All TA -40 85 °C Storage Temperature All Tstg -55 125 °C I/O Isolation voltage (100% factory Hi-Pot tested) All   2250 Vdc Operating Ambient Temperature (see Thermal Considerations section) Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Operating Input Voltage Maximum Input Current (VIN= VIN, min to VIN, max, IO=IO, max) Input No Load Current (VIN = 48V, IO = 0, module enabled) Input Stand-by Current Device Symbol Min Typ Max Unit All VIN 36 48 75 Vdc All IIN,max 2.0 Adc All IIN,No load 30 IIN,stand-by 5 All (VIN = 48V, module disabled) I2t mA 8 mA 0.5 A2s Inrush Transient All Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1μH source impedance; VIN, min to VIN, max, IO= IOmax ; See Test configuration section) All 30 mAp-p Input Ripple Rejection (120Hz) All 50 dB CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 5 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information. October 30, 2019 ©2016 General Electric Company. All rights reserved. Page 2 GE Data Sheet ESTW010A0A Series Eighth-Brick Power Modules 36–75Vdc Input; 5.0Vdc Output; 10A Output Current Electrical Specifications (continued) Parameter Device Symbol Min Typ Max Unit All VO, set 4.925 5.0 5.075 Vdc All VO 4.90  5.10 Vdc All All All       ±0.2 ±0.2 ±1.0 % VO, set % VO, set % VO, set All  25 50 mVrms mVpk-pk Nominal Output Voltage Set-point VIN= 48V IO=IO, max, TA=25°C) Output Voltage (Over all operating input voltage, resistive load, and temperature conditions until end of life) Output Regulation Line (VIN=VIN, min to VIN, max) Load (IO=IO, min to IO, max) Temperature (Tref=TA, min to TA, max) Output Ripple and Noise (Co=1uF,ceramic+10uF,tantalum, VIN=VIN, min to VIN, max, IO= IO, max , TA=TA, min to TA, max) RMS (5Hz to 20MHz bandwidth)  75 200 External Capacitance1 All CO 0  2,000 μF Output Current Output Current Limit Inception (Hiccup Mode ) (VO= 90% of VO, set) Output Short-Circuit Current (VO≤250mV) ( Hiccup Mode ) Efficiency All Io 0  10 Adc All IO, lim 105 120 130 % Io All IO, s/c 1.2 All η 91.0 % All fsw 350 kHz All Vpk  250  mV All ts  200  s Device Symbol Min Typ Max Unit Isolation Capacitance All Ciso  1000  pF Isolation Resistance All Riso 10   MΩ I/O Isolation Voltage (100% factory Hi-pot tested) All All   2250 Vdc Device Typ Max Peak-to-Peak (5Hz to 20MHz bandwidth) All VIN=48V, TA=25°C, IO=IO, max , VO= VO,set Switching Frequency Dynamic Load Response (Co=1uF,ceramic+10uF,tantalum, dIo/dt=0.1A/s; VIN = 48V; TA=25°C) Load Change from Io= 50% to 75% or 25% to 50% of Io,max Peak Deviation Settling Time (Vo
ESTW010A0A41-HZ 价格&库存

很抱歉,暂时无法提供与“ESTW010A0A41-HZ”相匹配的价格&库存,您可以联系我们找货

免费人工找货