0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PIM300AZ

PIM300AZ

  • 厂商:

    ABB

  • 封装:

    模块

  • 描述:

    非隔离 PoL 模块 直流转换器 1 输出 -48V 6.25A,1.6A -38V - -75V 输入

  • 数据手册
  • 价格&库存
PIM300AZ 数据手册
GE Data Sheet PIM300X Series; ATCA Board Power Input Modules -38 to -75Vdc; 300W Input Features RoHS Compliant ▪ 300W / -48V telecom input power distribution ▪ 8W (3.3Vdc or 5.0Vdc) of isolated Management Power for IPM or other housekeeping functions ▪ OR’ing functionality for the A/B & RTN power feeds as well as Enable A/B signals ▪ Inrush protection / hot swap capability ▪ Integral EMI filter designed for the ATCA board to meet CISPR Class B ▪ Independent 72Vdc output for charging the external holdup capacitors resulting in significant board real estate savings and bleed resistor power dissipation ▪ A/B Feed Loss or open fuse alarm (opto-isolated) ▪ Protection: Reverse polarity, under voltage, input transient over voltage, over current & over temperature Applications ▪ ATCA Front Board / Blade ▪ High efficiency : 98% @ –48V / 300W (@25C) ▪ Central Office Telecom equipment ▪ -5 to 85ºC ambient temperature operation ▪ High availability server and storage applications ▪ Compact design : 70.6 mm x 36.8 mm x 12.7 mm ▪ Compliant to RoHS Directive 2011/65/EU and amended Directive (EU) 2015/863. ▪ Compliant to REACH Directive (EC) No 1907/2006MTBF : 1,362,480 hours per TELCORDIA ▪ ISO** 9001 & ISO 14001 certified manufacturing facilities ▪ ANSI/UL* 62368-1 and CAN/CSA† C22.2 No. 62368-1 Recognized, DIN VDE‡ 0868-1/A11:2017 (EN62368-1:2014/A11:2017 ▪ Designed and tested for Basic Insulation (1500Vdc) Options ▪ ▪ Choice of System Management Power: ▪ 3.3Vdc (PIM300F) ▪ 5.0Vdc (PIM300A) Choice of short pin lengths Description The PIM300X-series is the higher power version of its highly successful predecessor, the PIM200X series. Besides providing higher power over extended temperature range, the module is pin compatible and retains the same form factor as the PIM200X series for ease of upgrading to higher power or thermally challenging ATCA board designs. The PIM200X/300X series are a new class of power modules designed to greatly simplify the task of implementing dual redundant, hot swap – 48Vdc power distribution with EMI filtering on an ATCA or other telecom boards. The PIM300X, when used with a variety of GE’s dc-dc converters/POLs provides for a quick, simple and elegant power architecture solution to a wide variety of complex power requirements. While providing high reliability, innovative features and compact design at a low cost, the module significantly reduces the valuable telecom board real estate compared to conventional discrete designs. Besides processing the main –48V bus, the module greatly simplifies the task of powering the IPM (for ATCA applications), system management or other housekeeping functions by providing a completely isolated auxiliary 3.3V or 5.0V power bus. * UL is a registered trademark of Underwriters Laboratories, Inc. †CSA is a registered trademark of Canadian Standards Association. ‡ VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards August 13, 2020 ©2012 General Electric Company. All rights reserved. GE Data Sheet PIM300X Series; ATCA Board Power Input Modules -38 to -75Vdc ; 300W Input 300W ATCA Board Typical Application F5 Short Pin (32) ENABLE_A Short Pin (27) ENABLE_B ENABLE_AF (5) ENABLE_BF (6) VRTN_AF (3) VRTN_BF (4) (8) 72V_CAP F6 F1 (28) VRTN_A (29) VRTN_B R_Bleed C_HLDP C_EMI F2 ATCA Backplane ATCA (25) Zone 1 Connector SHELF_GND (Optional) Long Pin (30) (13) U2 ON/OFF (9) F3 -48V_A (34) -48V_B -48V_AF (1) -48V_BF (2) (10) -48V_OUT Vin(-) (Optional) (26) 3K3 R2 (12) EARLY_B Vo(-) MGMT_PWR F4 Long Pin (31) +12V_BUS (Bus Converter) PIM300X EARLY_A (33) Vo(+) U1 C_FLTR (7) R1 Vin(+) VRTN_OUT 22uF -48V_ALARM Vcc LOGIC_GND C_EMI IPMC (System Controller) Enab le Payload Power (11) LOGIC_GND C _ HLDP (  F )  [ Po u t(W )  {T h o ld u p( ms) + 1.7}] / 1.9 R _ Bleed (  )  5 .485 / C _ HLDP ( F ) Suggested Bill of Materials (Note: Customer is ultimately responsible for the selection and verification of the suggested parts). Qty Ref Des Description (Values) 2 F1, F2 Fuse, SMT, 12 Amp 2 F3, F4 Fuse, SMT, 10 Amp 2 F5, F6 Fuse, SMT, 1/16th Amp 2 C_FLTR Capacitors, Al Electrolytic 100uF/100V Capacitors, Al Electrolytic 470uF/80V 4 OR 1 MFR / PN (or equivalent) C_HLDP Comments VRTN_A, VRTN_B Bel Fuse: SSQ Series Littelfuse 451/ 453 Series (Voltage rating >/=75V) Nippon/Chemicon; KZE Series Panasonic: FK Series (SMT) Nichicon: UJ Series Nippon/Chemicon; KZE Series Panasonic: FK Series (SMT) ENABLE_A, ENABLE_B C_FLTR(Max,Total) = 330 uF C_HLDP(calculated)=1737 uF (for 300W &Tholdup=9.3msecs) 1 R_Bleed OR Capacitors, Al Electrolytic 1800uF/80V SM, 2.9Kohms, 1W 2 C_EMI SM, 4700pF, >/=1500V Novacap, Murata or Syfer 1 U1 300W/12V Bus Converter GE: QBW025A0B1 1 U2 Opto-coupler (1500V) Fairchild: HMHA2801 Safety approved 2 R1*, R2* High Surge Power, 15 Ohms KOA: SG73 (Size >/=1206) *Optional; See “Design Consideration” Section August 13, 2020 OR Panasonic / ECEC1KP182DL 30mm(OD) X 20mm(L) -48V_A, -48V_B Snap-In Radial For C_HLDP=1800uF Size: >/=1210 ©2012 General Electric Company. All rights reserved. Page 2 GE Data Sheet PIM300X Series; ATCA Board Power Input Modules -38 to -75Vdc ; 300W Input Absolute Maximum Ratings: Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Typ -48 Max Unit Input Voltage (Absolute values) Continuous All VI 0 -75 Vdc Transient (Pulse duration above –75V = 1ms) All Vtr -75 -100 Vdc Normal Operating Ambient Temperature (See Thermal Considerations section) All TA -5 85 o C Storage Temperature All Tstg -55 125 o C All Pin, max 300 W All Vdelta 0.8V V All η 98 % Power Dissipation (Internal Module Dissipation @ Pin, max (with MGMT_PWR = 8W) All Pdiss 12 W Output Power, Maximum Deliverable (Management Power + Payload Power) All Pout 288 W Management Power, Maximum Deliverable (MGMT_PWR) All PMGMT_PWR Module Standby Power (@-48Vin & MGMT_PWR=0W, Pout=0W) All PStdby Temperature Power Input Power, Maximum Allowable Input to Output Voltage Differential @ -48Vin & Pin,max, TA=25 oC Efficiency VIN=-48V, Pin,max, TA=25 oC (MGMT_PWR=0W) 8 W 2.0 W Isolation Input to MGMT_PWR Output Voltage All 1500 Vdc Input to SHELF_GND Voltage All 1500 Vdc Input to LOGIC_GND Voltage All 1500 Vdc LOGIC_GND to SHELF_GND Insulation Resistance with 100Vdc Test Voltage All 9 MOhms CAUTION: This power module is not internally fused. Both A & B feeds and their corresponding returns must be individually fused. To preserve maximum flexibility, internal fusing is not included. However, to achieve maximum safety and system protection, the safety agencies require a fast-acting fuse with a maximum rating of 15 Amps and Voltage Rating >/= 75Vdc for the –48AF, -48BF VRTN_AF & VRTN_BF feeds. Consult Fusing and fault protection (Section 4.1.4) of PICMG 3.0 ATCA specifications for additional information. Based on the information provided in this data sheet on inrush current and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information. August 13, 2020 ©2012 General Electric Company. All rights reserved. Page 3 GE Data Sheet PIM300X Series; ATCA Board Power Input Modules -38 to -75Vdc ; 300W Input Electrical Specifications: Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Main Input (-48_AF,-48_BF,VRTN_AF,VRTN_BF); (Absolute values) Operating Input Voltage (Module will operate down to –36V depending on the output power and thermal environment but may not support holdup time requirements) All VI -38 -48 -75 Vdc Input Voltage Turn-on Threshold (Module On) All VUVHI -34.3 -35.3 -36.0 Vdc Under Voltage Lockout Threshold (Module Off) All VUVLO -32.4 -33.7 -34.1 Vdc Maximum current drain if input voltage falls below VUVLO for > 2 seconds. All Istdby 10 mA Maximum Input Current (VI=0V to -75Vdc, Pin=Pin, max) All II, max 9.0 Adc Inrush Transient (@ -48 VI and with C_FLTR = 200 F) All Ipk 20 (/= 100Vdc. • The minimum C_FLTR capacitance (200μF) recommendation is based on meeting the EMI requirements. Based on end systems test, the capacitance may be lowered if real estate is an issue. As a minimum, 50 μF to 100 μF is strongly recommended to stabilize the line impedance for proper startup of the DC/DC converter. Refer to the DC/DC converter’s data sheet for the recommended capacitor. (2) Holdup / Bulk Capacitor Output (72V_CAP) This output provides the high voltage (nominal 72Vdc) to charge the C_BULK capacitor(s) to allow the ATCA board to meet the 5ms, 0Volts transient requirements. • • • The 72V_CAP connects to the +ve terminals of the C_HLDP capacitors while the –ve terminals of the C_HLDP connects to the -48V_OUT bus. Since the 72V_CAP output is regulated to 72Vdc (+3%/-5%) and the capacitors are off line during normal operation, the capacitors may be selected with voltage rating of >/= 80V to minimize the real estate on the board. The C_HLDP capacitance is dependent on the system power and the holdup time requirements based on the following formula C _ HLDP(F )  [ Pout(W )  {Tholdup(ms) + 1.7}] / 1.9 • Bleed Resistor (R_Bleed) : The PICMG 3.0 specifications requires a discharge mechanism (e.g. bleed resistor) to discharge the holdup/bulk capacitance to less than -60Vdc and less than 20 joules within one second of disconnection from the backplane. This requirement is fulfilled by installing R_Bleed resistor that is selected based on the C_HLDP selected in the previous step. The formula for selecting the resistor is : R _ Bleed ()  5.485 / C _ HLDP( F ) For 300W and 9.3 ms holdup requirements, this results in a 2.9 Kohm resistor with 1W rating. Worst case power dissipation of R_Bleed (=2.9Kohms) @ -36V is 0.45W. August 13, 2020 • The R_Bleed is connected across the 72V_CAP and VRTN_OUT pins of the PIM300X. (3) Management Power (MGMT_PWR) The MGMT_PWR output is an isolated secondary voltage (3.3V for PIM300F or 5.0V for PIM300A) referenced to LOGIC_GND that provides 8W(maximum) power to the IPM Controller for the ATCA board or to the power up system controller for other applications. • Per PICMG 3.0 Specs, the ATCA board shall not consume more than 10W of input power; this includes the standby power of PIM300X (typically 1.7W) as well as all the on board DC/DC power converters. It is the responsibility of the board designer to insure that this requirement is met prior to power-up rights have been negotiated with the Shelf Manager. • The management power is available even when the input voltage is down to –36Vdc. • No additional output capacitors are required, but a 22μF tantalum/ceramic and a 0.01 to 0.1μF ceramic capacitors are highly recommended to contain the switching ripple and noise. • Higher output capacitance may be required in case of large input line or output load transient conditions. (4) -48V Feed Loss or Open Fuse Alarm (-48V_ALARM) The -48V_ALARM output is an opto-isolated signal internally referenced to the LOGIC_GND. The signal is an open collector output that requires an external pull up resistor. A 3.3K pull up resistor to 3.3V, MGMT_PWR (for PIM300F) should suffice. During normal operation, the signal is LO (opto conducting). During fault condition, the opto shall stop conducting and the alarm signal shall assume a HI state. Safety Considerations For safety agency approval the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standards, i.e., UL ANSI/UL* 62368-1 and CAN/CSA+ C22.2 No. 62368-1 Recognized, DIN VDE 0868-1/A11:2017 (EN62368-1:2014/A11:2017) The power input to these units is to be provided with a maximum of 15 Amps fuses with a voltage rating of at least 75Vdc. Refer to “Thermal Consideration” section for additional safety considerations. ©2012 General Electric Company. All rights reserved. Page 13 GE Data Sheet PIM300X Series; ATCA Board Power Input Modules -38 to -75Vdc ; 300W Input Figure 17. Typical Class B EMC signature of PIM300F with QBW025A0B1 module. Feature Description A/B Feed OR’ing The module provides dedicated OR’ing functionality to both Feeds A & B and their corresponding returns. The following pairs of signals are OR’d within the module: -48V_AF / -48_BF, VRTN_AF / VRTN_BF, and ENABLE_AF/ ENABLE_B. The -48V A/B feeds and their corresponding returns are OR’d via N-channel MOSFET power devices resulting in a highly efficient system compared to conventional diode OR’ing scheme. Inrush Current Control / Hot Plug Functionality EMI Filtering The module incorporates an EMI filter that is designed for the ATCA board to help meet the conducted emissions requirements of CISPR 22 Class B when used in conjunction with GE DC/DC converters approved for ATCA applications. The following insertion loss table is provided as filter performance guidelines. Parameter For Safety and noise considerations, copper traces must not be routed directly beneath the power module (PWB top layer). C_EMI capacitors must make direct connections (preferably without vias) to the DC/DC module pins with as much copper width as possible. In case vias are necessary, allow for multiple connections to the inner plane with vias placed outside the footprint of the module. For additional layout guide-lines, refer to GE’s FLT007A0 Input Filter Module data sheet. The module provides inrush current control / hot plug capability. The peak value of the inrush current and the duration complies with the PICMG 3.0’s Inrush Transient specifications. The specifications shall be met with the external C_HLDP and C_FLTR capacitances as specified in the previous sections. The unique design of the module where the large energy storage capacitors are segregated from the input filter capacitors allows the module to meet the stringent PICMG’s inrush transient specifications. In conventional designs where the energy storage capacitors and the filter capacitors are in parallel, it is extremely difficult to meet the inrush transient specifications without over sizing the inrush control power FET. Typical Unit 50 Ohms circuit, 200kHz 24 dB 50 Ohms circuit, 500kHz 32 dB 50 Ohms circuit, 1MHz 39 dB 50 Ohms circuit, 200kHz 75 dB A/B Feed / Fuse Alarm (-48V_ALARM) 50 Ohms circuit, 500kHz 66 dB 50 Ohms circuit, 1MHz 61 dB The module monitors the A & B feeds as well as the status of the A&B feed fuses and provides an optoisolated signal in case of loss of a feed or the opening of any of the fuses. The response time of the fault condition is < 100 μsec. The alarm signal indicates normal operation when the opto coupler transistor is conducting and a fault condition by an off state. Common-Mode Insertion Loss Differential-mode Insertion Loss The following Figure 17 depicts the Class B EMI performance of PIM300F when tested with QBW025A0B1 on a stand alone basis (ATCA form factor load board with resistive loads and only power, return and chassis connections to the backplane). The external filtering components are identified in the Typical Application circuit. August 13, 2020 Holdup Capacitor Charging Current (72V_CAP) The module employs a unique feature to charge and recharge the external energy storage holdup/bulk capacitors (C_HLDP) within seconds from the application of power to a nominal voltage of 72Vdc (+3%/-5%) resulting in significant reduction in the real estate on the board in order to comply with the PICMG 3.0’s 0 volt/5msec transient requirements. Since the 72V_CAP is also regulated, there is further reduction in real estate board because now 80V capacitors with higher capacitance can be used instead of the >/= 100Vdc caps required in conventional designs. The maximum rate of input voltage change (dv/dt) shall not exceed 5V/ms when the -72V_CAP output is switched on the 48V_OUT/VRTN_OUT bus. ©2012 General Electric Company. All rights reserved. Page 14 GE Data Sheet PIM300X Series; ATCA Board Power Input Modules -38 to -75Vdc ; 300W Input The holdup capacitors are switched on automatically when there is a loss of power on both feeds A & B or both feeds have dropped below –38V (typical). Upon restoration of normal power on either or both feeds, the holdup capacitors automatically go off line and are recharged for the next power loss event. Note 1: The holdup capacitors and the bleed resistor are installed external to the module. Note 2: The PICMG 3.0’s requirements for the 0 Vdc transient for 5ms is normally interpreted as the holdup time requirement by many. In actuality, when one considers the additional specification of 50V/ms fall time and 12.5 V/ms rise time to and from the 0Vdc condition, this leads to a 9.3ms of total hold up time requirement when power is interrupted at -43Vdc. The 72V_CAP output provided by the module to charge the bulk capacitors provides a tremendous advantage over conventional designs in terms of real estate requirements on the board with the added benefit of the usage of 80V capacitor rating vs >/=100V. The holdup time, Tholdup, is defined for power loss at 43Vdc input and the C_HLDP maintaining -48V_OUT bus to at least –36Vdc (which is the minimum operating voltage of the downstream DC/DC bus converter). Note 3: Bleed Resistor (R_Bleed): Normally, the bleed resistor is not required as there is sufficient standby current drain within the module to bleed the holdup capacitors from 75V to 60V in 1 second as specified in the PICMG 3.0. Again, due to the PIM300X’s unique design, the placement of the bleed resistor results in significantly less power dissipation compared with conventional designs where the bleed resistor is sized for -75Vdc continuous maximum voltage and -100V transients. the downstream DC/DC converters from input voltage transients exceeding -75Vdc. The TVS is rated for 1500W of Peak Pulse Power with the Breakdown Voltage (VBR) of 77.8V to 86.0V. Input Reverse Polarity Protection The module shall not be damaged from reverse polarity connection in the event of miswiring of either input feeds at the shelf input terminals. Over Temperature Protection To provide over temperature protection in a fault condition, the unit will shutdown if any thermal sensor reference point TOTP (identified in Figure 16), exceeds the trip point of 125oC (+/- 5oC). The thermal shutdown is not intended as a guarantee that the unit will survive temperatures beyond its rating. The module will automatically restart after it cools down. During thermal design verification, it is recommended that these temperatures be monitored by IR Thermal imaging camera. In case thermocouples are used, the thermocouple contacts should be attached as close as possible to the thermal sensors (thermistors) on the PWB but not directly on the thermistors themselves. Attaching the contacts directly to the thermocouple is not recommended as this will result in false temperature measurements due to the heat sink effect of the thermocouple wires. Management Power (MGMT_PWR) • The module provides up to 8W of 3.3V (PIM300F) or 5.0V (PIM300A) of isolated output power referred to LOGIC_GND. • The management power is available automatically as soon as the input voltage levels are within –36Vdc to –75Vdc. • The output is short circuit and over voltage protected with low ripple and noise. Over Current Protection (- 48V_OUT Bus) To provide protection in a fault (output overload or short circuit) condition, the unit is equipped with internal current-limiting circuitry. The unit can endure current overload conditions continuously or shutdown due to thermal protection depending on operating ambient temperature conditions. The unit will restart automatically once the overload condition is removed. Input Under Voltage Lockout At input voltages below the input under voltage lockout threshold limit (VUVLO), the module operation is disabled. The module will begin to operate at an input voltage above the under voltage lockout turn-on threshold(VUVHI). Please see the Electrical Specifications Table for the specified trip points. Thermal Considerations Power modules operate in a variety of thermal environments; however, sufficient cooling should be provided to help ensure reliable operation. Considerations include ambient temperature, airflow, module power dissipation, and the need for increased reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The thermal data presented here is based on physical measurements taken in a wind tunnel. The test set-up is shown below in Figure 18. Transient Over Voltage Protection The module incorporates a Transient Voltage Suppressor. This feature helps protect the module and August 13, 2020 ©2012 General Electric Company. All rights reserved. Page 15 GE Data Sheet PIM300X Series; ATCA Board Power Input Modules -38 to -75Vdc ; 300W Input 25.4_ (1.0) Wind Tunne l PWBs Po w e r Mo d ule 76.2_ (3.0) Reflow Lead-Free Soldering Information x 5.97_ (0.235) through single or dual wave soldering machines. The pins have an RoHS-compliant finish that is compatible with both Pb and Pb-free wave soldering processes. A maximum preheat rate of 3C/s is suggested. The wave preheat process should be such that the temperature of the power module board is kept below 210C. For Pb solder, the recommended pot temperature is 260C, while the Pb-free solder pot is 270C max. If additional information is needed, please consult with your Sales representative for more details. Pro b e Lo c a tio n fo r m e a suring a irflo w a nd a m b ie nt te m p e ra ture Air flo w Figure 18. Thermal Test Set-up The thermal derating curves were generated with the airflow parallel to the long axis of the module (input to output). The thermal reference points, Tref 1 to Tref 3 are identified in Figure 15. For reliable operation and to comply with the module’s safety requirements, these temperatures should not exceed the limits specified in the figure. Exceeding these temperatures may or may not trigger the over temperature shutdown. The output power of the module should not exceed the rated input power of the module i.e. 300W. Please refer to the Application Note “Thermal Characterization Process For Open-Frame BoardMounted Power Modules” for a detailed discussion of thermal aspects including maximum device temperatures. Heat Transfer via Convection Increased airflow over the module enhances the heat transfer via convection. Thermal derating curves showing the maximum output current that can be delivered by the module versus local ambient temperature (TA) are shown in the Thermal derating curves, Figs 13-1 to 13-4 for PIM300F and Figs 14-1 to 14-4 for PIM300A. The RoHS-compliant through-hole products can be processed with Pb-free reflow process. However, since the modules are not packed in vacuum sealed Moisture Barrier Bags (MBB), the modules need to be baked to prevent any printed wiring board (PWB) delamination. The modules should be baked at 125C for 4 hours prior to use. The recommended reflow profile is described below. Max. sustain temperature : 245C (J-STD-020C Table 4-2: Packaging Thickness>=2.5mm / Volume > 2000mm3), Peak temperature over 245C is not suggested due to the potential reliability risk of components under continuous high-temperature. Min. sustain duration above 217C: 90 seconds Min. sustain duration above 180C: 150 seconds Max. heat up rate: 3C/sec Max. cool down rate: 4C/sec In compliance with JEDEC J-STD-020C spec for 2 times reflow requirement. Pb-free Reflow Profile BMP module will comply with J-STD-020 Rev. C (Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices) for both Pb-free solder profiles and MSL classification procedures. BMP will comply with JEDEC J-STD-020C specification for 3 times reflow requirement. The suggested Pb-free solder paste is Sn/Ag/Cu (SAC). The recommended linear reflow profile using Sn/Ag/Cu solder is shown in Figure 19. Manufacturing Considerations Through-Hole Lead Free Soldering Information The RoHS-compliant through-hole products use the SAC (Sn/Ag/Cu) Pb-free solder and RoHS-compliant components. They are designed to be processed August 13, 2020 ©2012 General Electric Company. All rights reserved. Page 16 GE Data Sheet PIM300X Series; ATCA Board Power Input Modules -38 to -75Vdc ; 300W Input Temp Peak Temp. 240-245°C Ramp down max. 4°C/Sec 217°C 200°C Time Limited 90 Sec. above 217°C 150°C Preheat time 100-150 Sec. Ramp up max. 3°C/Sec 25°C Time Figure 19. Recommended linear reflow profile using Sn/Ag/Cu solder. Post Solder Cleaning and Drying Considerations Post solder cleaning is usually the final circuit-board assembly process prior to electrical board testing. The result of inadequate cleaning and drying can affect both the reliability of a power module and the testability of the finished circuit-board assembly. For guidance on appropriate soldering, cleaning and drying procedures, refer to GE’s Electronics Board Mounted Power Modules: Soldering and Cleaning Application Note (AP01-056EPS) August 13, 2020 ©2012 General Electric Company. All rights reserved. Page 17 GE Data Sheet PIM300X Series; ATCA Board Power Input Modules -38 to -75Vdc ; 300W Input Mechanical Outline Dimensions are in millimeters and (inches). Tolerances: x.x mm  0.5 mm (x.xx in.  0.02 in.) [unless otherwise indicated] x.xx mm  0.25 mm (x.xxx in  0.010 in.) TOP VIEW SIDE VIEW BOTTOM VIEW August 13, 2020 ©2012 General Electric Company. All rights reserved. Page 18 GE Data Sheet PIM300X Series; ATCA Board Power Input Modules -38 to -75Vdc ; 300W Input Recommended Pad Layout Dimensions are in millimeters and (inches). Tolerances: x.x mm  0.5 mm (x.xx in.  0.02 in.) [unless otherwise indicated] x.xx mm  0.25 mm (x.xxx in  0.010 in.) NOTES: 1. For the pins, use 1.27(mm) / 0.050(in) diameter Plated Trough Hole August 13, 2020 ©2012 General Electric Company. All rights reserved. Page 19 GE Data Sheet PIM300X Series; ATCA Board Power Input Modules -38 to -75Vdc ; 300W Input Ordering Information Please contact your GE’s Sales Representative for pricing, availability and optional features. Table 1. Device Code Input Voltage Power Rating Auxiliary Output Voltage Auxiliary Output Current Connector Type & Options Product codes Comcodes -38 to -75 Vdc 300W 3.3Vdc 2.4A Thru Hole/RoHS PIM300FZ CC109113858 -38 to -75 Vdc 300W 5.0Vdc 1.6A Thru Hole/RoHS PIM300AZ CC109122322 -38 to -75 Vdc 300W 3.3Vdc 2.4A Thru Hole/RoHS PIM300F6Z CC109159190 -38 to -75 Vdc 300W 5.0Vdc 2.4A Thru Hole/RoHS PIM300A6Z 150038129 Table 2. Device Options Option Device Code Suffix Short pins: 3.68mm ± 0.25mm (0.145 in. ± 0.010 in.) Short pins: 2.79mm ± 0.25mm (0.110 in. ± 0.010 in.) 6 8 Contact Us For more information, call us at USA/Canada: +1 888 546 3243, or +1 972 244 9288 Asia-Pacific: +86-21-53899666 Europe, Middle-East and Africa: +49.89.878067-280 Go.ABB/Industrial GE Critical Power reserves the right to make changes to the product(s) or information contained herein without notice, and no liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. August 13, 2020 ©2020 General Electric Company. All International rights reserved. Version 1_7
PIM300AZ 价格&库存

很抱歉,暂时无法提供与“PIM300AZ”相匹配的价格&库存,您可以联系我们找货

免费人工找货