0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
QBVW033A0B641-HZ

QBVW033A0B641-HZ

  • 厂商:

    ABB

  • 封装:

    DIP5 模块,1/4砖

  • 描述:

    中间总线转换器 直流转换器 1 输出 12V 33A 36V - 75V 输入

  • 数据手册
  • 价格&库存
QBVW033A0B641-HZ 数据手册
GE Data Sheet QBVW033A0B Barracuda* Series; DC-DC Converter Power Modules 36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output RoHS Compliant Features ▪ Compliant to RoHS Directive 2011/65/EU and amended Directive (EU) 2015/863 (-Z versions) ▪ Compliant to REACH Directive (EC) No 1907/2006 ▪ Compatible with reflow pin/paste soldering process ▪ High and flat efficiency profile >95.5% at 12Vdc, 30% load to 100% output ▪ Wide Input voltage range: 36-75Vdc ▪ Delivers up to 33Adc output current ▪ Fully very tightly regulated output voltage ▪ Low output ripple and noise ▪ Industry standard, DOSA Compliant Quarter Brick: 58.4 mm x 36.8 mm x 11.7 mm (2.30 in x 1.45 in x 0.46 in) Applications ▪ Constant switching frequency ▪ Distributed power architectures ▪ Intermediate bus voltage applications ▪ Servers and storage applications ▪ Networking equipment including Power over Ethernet (PoE) ▪ Fan assemblies and other systems requiring a tightly regulated output voltage ▪ Positive Remote On/Off logic ▪ Output over current/voltage protection Options ▪ Negative Remote On/Off logic (1=option code, factory preferred) ▪ Auto-restart after fault shutdown (4=option code, factory preferred) ▪ Remote Sense and Output Voltage Trim (9=option code) ▪ Base plate option (-H=option code) ▪ Passive Droop Load Sharing (-P=option code) ▪ Over temperature protection ▪ Wide operating temperature range (-40°C to 85°C) ▪ ANSI/UL# 62368-1 and CAN/CSA† C22.2 No. 62368-1 Recognized, DIN VDE‡ 0868-1/A11:2017 (EN62368-1:2014/A11:2017) ▪ CE mark to 2014/35/EU directive§ ▪ Meets the voltage and current requirements for ETSI 300-132-2 and complies with and licensed for Basic insulation rating ▪ 2250 Vdc Isolation tested in compliance with IEEE 802.3¤ PoE standards ▪ ISO** 9001 and ISO14001 certified manufacturing facilities Description The QBVW033A0B series of dc-dc converters are a new generation of fully regulated DC/DC power modules designed to support 12Vdc intermediate bus applications where multiple low voltages are subsequently generated using point of load (POL) converters, as well as other application requiring a tightly regulated output voltage. The QBVW033A0B series operate from an input voltage range of 36 to 75Vdc and provide up to 33A output current at output voltages of 12Vdc in an industry standard, DOSA compliant quarter brick. The converter incorporates digital control, synchronous rectification technology, a fully regulated control topology, and innovative packaging techniques to achieve efficiency exceeding 96% at 12V output. This leads to lower power dissipations such that for many applications a heat sink is not required. Standard features include on/off control, output overcurrent and over voltage protection, over temperature protection, input under and over voltage lockout. The output is fully isolated from the input, allowing versatile polarity configurations and grounding connections. Built-in filtering for both input and output minimizes the need for external filtering. * Trademark of General Electric Company # UL is a registered trademark of Underwriters Laboratories, Inc. † CSA is a registered trademark of Canadian Standards Association. ‡ VDE is a trademark of Verband Deutscher Elektrotechniker e.V. § This product is intended for integration into end-user equipment . All of the required procedures of end-use equipment should be followed. ¤ IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Incorporated. ** ISO is a registered trademark of the International Organization of Standards. April 29, 2021 ©2012 General Electric Company. All rights reserved. Page 1 GE Data Sheet QBVW033A0B Barracuda Series; DC-DC Converter Power Modules 36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the Data Sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability. Parameter Device Symbol Min Max Unit VIN -0.3 75 Vdc 100 Vdc VIN 80 100 Vdc All TA -40 85 °C All Tstg -55 125 °C ⎯ ⎯ * Input over voltage protection will shutdown the output voltage when the input voltage exceeds threshold level. 2250 Vdc Input Voltage* Continuous Operating transient ≤ 100mS Non- operating continuous Operating Ambient Temperature (See Thermal Considerations section) Storage Temperature I/O Isolation Voltage (100% factory Hi-Pot tested) All Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Operating Input Voltage Maximum Input Current (VIN=0V to 75V, IO=IO, max) Input No Load Current (VIN = VIN, nom, IO = 0, module enabled) Input Stand-by Current (VIN = VIN, nom, module disabled) Symbol Min Typ Max Unit VIN 36 48 75 Vdc IIN,max - - 12 Adc All IIN,No load All IIN,stand-by External Input Capacitance All Inrush Transient All 80 mA 22 mA 100 - - μF - - 1 A2s All - 350 - mArms Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 12μH source impedance; VIN= 48V, IO= IOmax ; see Figure 11) All - 40 - mAp-p Input Ripple Rejection (120Hz) All - 25 - dB I2t Input Terminal Ripple Current (Measured at module input pin with maximum specified input capacitance and < 500uH inductance between voltage source and input capacitance) 5Hz to 20MHz, VIN= 48V, IO= IOmax CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 30 A in the ungrounded input lead of the power supply (see Safety Considerations section). Based on the information provided in this Data Sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s Data Sheet for further information. April 29, 2021 ©2012 General Electric Company. All rights reserved. Page 2 GE Data Sheet QBVW033A0B Barracuda Series; DC-DC Converter Power Modules 36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output Electrical Specifications (continued) Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Output Voltage Set-point (VIN=VIN,nom, IO=16.5A, TA =25°C) Output Voltage (Over all operating input voltage (40V to 75V), resistive load, and temperature conditions until end of life) Output Voltage (VIN=36V, TA = 25ºC) Device Symbol Min Typ Max Unit All All w/o P Option All w/ P Option All VO, set 11.97 12.00 12.03 Vdc VO 11.76 ⎯ 12.24 Vdc VO 11.63 ⎯ 12.37 Vdc VO 11.00 ⎯ ⎯ Vdc All w/o 9 option All w/ 9 option All w/o P or 9 option All w/ 9 option All w/ P Option All ⎯ 0.2 ⎯ % VO, set ⎯ 0.5 ⎯ % VO, set ⎯ 0.2 ⎯ % VO, set ⎯ 1.2 ⎯ % VO, set ⎯ 0.50 ⎯ Vdc ⎯ 2 ⎯ % VO, set All ⎯ 70 ⎯ mVrms All ⎯ 200 ⎯ mVpk-pk 0 ⎯ 10,000 μF 15,000 μF 33 Adc ⎯ Adc Output Regulation [VIN, min = 40V] Line (VIN= VIN, min to VIN, max) Line (VIN= VIN, min to VIN, max) Load (IO=IO, min to IO, max) Load (IO=IO, min to IO, max) Load (IO=IO, min to IO, max), Intentional Droop Temperature (TA = -40ºC to +85ºC) Output Ripple and Noise on nominal output (VIN=VIN, nom and IO=IO, min to IO, max) RMS (5Hz to 20MHz bandwidth) Peak-to-Peak (5Hz to 20MHz bandwidth) External Output Capacitance For CO >5000uF, IO must be < 50% IO, max during Trise. When 2 or more modules are in parallel All CO, max -P Option 0 Output Current All IO 0 Output Current Limit Inception All IO,lim 36.3 40 Efficiency (VIN=VIN, nom, TA=25°C) IO=100% IO, max, VO= VO,set All IO=40% IO, max to 75% IO, max , VO= VO,set All Switching Frequency 95.5 η 96.0 % fsw 150 kHz Dynamic Load Response dIO/dt=1A/10s; Vin=Vin,nom; TA=25°C; (Tested with a 1.0μF ceramic, a 10μF tantalum, and 470μF capacitor and across the load.) Load Change from IO = 50% to 75% of IO,max: Peak Deviation Settling Time (VO 2000mm3), Peak temperature over 245C is not suggested due to the potential reliability risk of components under continuous hightemperature. Min. sustain duration above 217C : 90 seconds Min. sustain duration above 180C : 150 seconds Max. heat up rate: 3C/sec Max. cool down rate: 4C/sec In compliance with JEDEC J-STD-020C spec for 2 times reflow requirement. Pb-free Reflow Profile BMP module will comply with J-STD-020 Rev. C (Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices) for both Pbfree solder profiles and MSL classification procedures. BMP will comply with JEDEC J-STD-020C specification for 3 times reflow requirement. The suggested Pb-free solder paste is Sn/Ag/Cu (SAC). The recommended linear reflow profile using Sn/Ag/Cu solder is shown in Figure 24. April 29, 2021 Preheat time 100-150 Sec. Ramp up max. 3°C/Sec 25°C Time Figure 25. Recommended linear reflow profile using Sn/Ag/Cu solder. MSL Rating The QBVW033A0B modules have a MSL rating as indicated in the Device Codes table, last page of this document. Storage and Handling The recommended storage environment and handling procedures for moisture-sensitive surface mount packages is detailed in J-STD-033 Rev. A (Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive Surface Mount Devices). Moisture barrier bags (MBB) with desiccant are required for MSL ratings of 2 or greater. These sealed packages should not be broken until time of use. Once the original package is broken, the floor life of the product at conditions of 30°C and 60% relative humidity varies according to the MSL rating (see J-STD-033A). The shelf life for dry packed SMT packages will be a minimum of 12 months from the bag seal date, when stored at the following conditions: < 40° C, < 90% relative humidity. Post Solder Cleaning and Drying Considerations Post solder cleaning is usually the final circuit-board assembly process prior to electrical board testing. The result of inadequate cleaning and drying can affect both the reliability of a power module and the testability of the finished circuit-board assembly. For guidance on appropriate soldering, cleaning and drying procedures, refer to GE Board Mounted Power Modules: Soldering and Cleaning Application Note (AN04-001). If additional information is needed, please consult with your GE representative for more details. ©2012 General Electric Company. All rights reserved. Page 12 GE Data Sheet QBVW033A0B Barracuda Series; DC-DC Converter Power Modules 36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output EMC Considerations The circuit and plots in Figure 25 shows a suggested configuration to meet the conducted emission limits of EN55032 Class A. For further information on designing for EMC compliance, please refer to the FLT012A0Z data sheet. Figure 26. EMC Considerations April 29, 2021 ©2012 General Electric Company. All rights reserved. Page 13 GE Data Sheet QBVW033A0B Barracuda Series; DC-DC Converter Power Modules 36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output Mechanical Outline for QBVW033A0B Through-hole Module Dimensions are in millimeters and [inches]. Tolerances: x.x mm  0.5 mm [x.xx in.  0.02 in.] (Unless otherwise indicated) x.xx mm  0.25 mm [x.xxx in  0.010 in.] *Top side label includes GE name, product designation, and data code. ** Standard pin tail length. Optional pin tail lengths shown in Table 2, Device Options. TOP VIEW* SIDE VIEW BOTTOM VIEW Pin Pin Number Name 1* VIN(+) 2* ON/OFF 3* VIN(-) 4* VOUT(-) 5† SENSE(-) 6† TRIM 7† SENSE(+) 8* VOUT(+) † - Optional Pins See Table 2 April 29, 2021 ©2012 General Electric Company. All rights reserved. Page 14 GE Data Sheet QBVW033A0B Barracuda Series; DC-DC Converter Power Modules 36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output Mechanical Outline for QBVW033A0B-H (Base plate) Through-hole Module Dimensions are in millimeters and [inches]. Tolerances: x.x mm  0.5 mm [x.xx in.  0.02 in.] (Unless otherwise indicated) x.xx mm  0.25 mm [x.xxx in  0.010 in.] *Side label includes product designation, and data code. ** Standard pin tail length. Optional pin tail lengths shown in Table 2, Device Options. ***Bottom label includes GE name, product designation, and data code TOP VIEW SIDE VIEW* BOTTOM VIEW*** Pin Pin Number Name 1* VIN(+) 2* ON/OFF 3* VIN(-) 4* VOUT(-) 5† SENSE(-) 6† TRIM 7† SENSE(+) 8* VOUT(+) † - Optional Pins See Table 2 April 29, 2021 ©2012 General Electric Company. All rights reserved. Page 15 GE Data Sheet QBVW033A0B Barracuda Series; DC-DC Converter Power Modules 36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output Recommended Pad Layouts Dimensions are in millimeters and [inches]. Tolerances: x.x mm  0.5 mm [x.xx in.  0.02 in.] (unless otherwise indicated) x.xx mm  0.25 mm [x.xxx in  0.010 in.] Through-Hole Modules Pin Pin Number Name 1* VIN(+) 2* ON/OFF 3* VIN(-) 4* VOUT(-) 5† SENSE(-) 6† TRIM 7† SENSE(+) 8* VOUT(+) † - Optional Pins See Table 2 Hole and Pad diameter recommendations: Pin Number Hole Dia mm [in] 1, 2, 3, 5, 6, 7 1.6 [.063] 4, 8 2.2 [.087] April 29, 2021 Pad Dia mm [in] 2.1 [.083] 3.2 [.126] ©2012 General Electric Company. All rights reserved. Page 16 GE Data Sheet QBVW033A0B Barracuda Series; DC-DC Converter Power Modules 36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output Packaging Details All versions of the QBVW033A0Bare supplied as standard in the plastic trays shown in Figure 27. Tray Specification Material PET (1mm) Max surface resistivity 109 -1011/PET Color Clear Capacity 12 power modules Min order quantity 24 pcs (1 box of 2 full trays + 1 empty top tray) Each tray contains a total of 12 power modules. The trays are self-stacking and each shipping box for the QBVW033A0B module contains 2 full trays plus one empty hold-down tray giving a total number of 24 power modules. Open Frame Module Tray Base Plate Module Tray Figure 27. QBVW033 Packaging Tray April 29, 2021 ©2012 General Electric Company. All rights reserved. Page 17 GE Data Sheet QBVW033A0B Barracuda Series; DC-DC Converter Power Modules 36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output Ordering Information Please contact your GE Sales Representative for pricing, availability and optional features. Table 1. Device Codes Product codes QBVW033A0B41Z QBVW033A0B64Z QBVW033A0B541Z QBVW033A0B641Z QBVW033A0B841Z QBVW033A0B1-HZ QBVW033A0B41-HZ QBVW033A0B61-HZ QBVW033A0B64-HZ QBVW033A0B641-HZ QBVW033A0B841-HZ QBVW033A0B941-HZ QBVW033A0B964-HZ QBVW033A0B9641-HZ QBVW033A0B41-PZ QBVW033A0B541-PZ QBVW033A0B841-PZ QBVW033A0B1-PHZ QBVW033A0B41-PHZ QBVW033A0B61-PHZ QBVW033A0B641-PHZ April 29, 2021 Input Voltage 48V (36−75Vdc) 48V (36−75Vdc) 48V (36−75Vdc) 48V (36−75Vdc) 48V (36−75Vdc) 48V (36−75Vdc) 48V (36−75Vdc) 48V (36−75Vdc) 48V (36−75Vdc) 48V (36−75Vdc) 48V (36−75Vdc) 48V (36−75Vdc) 48V (36−75Vdc) 48V (36−75Vdc) 48V (36−75Vdc) 48V (36−75Vdc) 48V (36−75Vdc) 48V (36−75Vdc) 48V (36−75Vdc) 48V (36−75Vdc) 48V (36−75Vdc) Output Voltage 12V 12V 12V 12V 12V 12V 12V 12V 12V 12V 12V 12V 12V 12V 12V 12V 12V 12V 12V 12V 12V Output Current 33A 33A 33A 33A 33A 33A 33A 33A 33A 33A 33A 33A 33A 33A 33A 33A 33A 33A 33A 33A 33A Efficiency 95.5% 95.5% 95.5% 95.5% 95.5% 95.5% 95.5% 95.5% 95.5% 95.5% 95.5% 95.5% 95.5% 95.5% 95.5% 95.5% 95.5% 95.5% 95.5% 95.5% 95.5% ©2012 General Electric Company. All rights reserved. Connector Type Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole Through hole MSl Rating 2a 2a 2a 2a 2a 2a 2a 2a 2a 2a 2a 2a 2a 2a 2a 2a 2a 2a 2a 2a 2a Comcodes CC109165247 150023767 CC109165263 CC109165692 CC109169347 CC109168126 CC109165255 CC109167813 150023766 CC109165701 150027041 CC109170627 150026356 150019350 CC109169314 CC109167086 CC109169355 CC109167094 CC109167103 CC109167111 CC109167540 Page 18 GE Data Sheet QBVW033A0B Barracuda Series; DC-DC Converter Power Modules 36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output Table 2. Device Options Contact Us For more information, call us at USA/Canada: +1 877 546 3243, or +1 972 244 9288 Asia-Pacific: +86-21-53899666 Europe, Middle-East and Africa: +49.89.878067-280 Go.ABB/Industrial GE Critical Power reserves the right to make changes to the product(s) or information contained herein without notice, and no liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. April 29, 2021 ©2016 General Electric Company. All rights reserved. Version 1_6
QBVW033A0B641-HZ 价格&库存

很抱歉,暂时无法提供与“QBVW033A0B641-HZ”相匹配的价格&库存,您可以联系我们找货

免费人工找货