SST39VF6402B-70-4C-B1KE-T 数据手册
Not recommended for new designs.
Please use SST38VF6401/6402/6403/6404.
64 Mbit (x16) Multi-Purpose Flash Plus
SST39VF6401B / SST39VF6402B
Not Recommended for New Designs
The SST39VF6401B / SST39VF6402B devices are 4M x16, CMOS Multi-Purpose
Flash Plus (MPF+) manufactured with proprietary, high performance CMOS
SuperFlash technology. The split-gate cell design and thick-oxide tunneling injector attain better reliability and manufacturability compared with alternate
approaches. The SST39VF6401B / SST39VF6402B write (Program or Erase)
with a 2.7-3.6V power supply. These devices conform to JEDEC standard pinouts
for x16 memories and are command set compatible with other Flash devices,
enabling customers to save time and resources in implementation.
Features
• Organized as 4M x16
• Fast Read Access Time:
– 70 ns
• Single Voltage Read and Write Operations
• Latched Address and Data
– 2.7-3.6V
• Superior Reliability
• Fast Erase and Word-Program:
– Endurance: 100,000 Cycles (Typical)
– Greater than 100 years Data Retention
• Low Power Consumption (typical values at 5 MHz)
– Active Current: 9 mA (typical)
– Standby Current: 3 µA (typical)
– Auto Low Power Mode: 3 µA (typical)
• Hardware Block-Protection/WP# Input Pin
– Top Block-Protection (top 32 KWord)
for SST39VF6402B
– Bottom Block-Protection (bottom 32 KWord)
for SST39VF6401B
• Sector-Erase Capability
– Uniform 2 KWord sectors
• Block-Erase Capability
– Uniform 32 KWord blocks
• Chip-Erase Capability
• Erase-Suspend/Erase-Resume Capabilities
• Hardware Reset Pin (RST#)
• Security-ID Feature
– Sector-Erase Time: 18 ms (typical)
– Block-Erase Time: 18 ms (typical)
– Chip-Erase Time: 40 ms (typical)
– Word-Program Time: 7 µs (typical)
• Automatic Write Timing
– Internal VPP Generation
• End-of-Write Detection
– Toggle Bits
– Data# Polling
• CMOS I/O Compatibility
• JEDEC Standard
– Flash EEPROM Pin Assignments
– Software command sequence compatibility
- Address format is 11 bits, A10-A0
- Block-Erase 6th Bus Write Cycle is 30H
- Sector-Erase 6th Bus Write Cycle is 50H
• Packages Available
– 48-lead TSOP (12mm x 20mm)
– 48-ball TFBGA (8mm x 10mm)
• All devices are RoHS compliant
– Microchip: 128 bits; User: 128 bits
©2015-2018
www.microchip.com
DS20005008C
64 Mbit Multi-Purpose Flash Plus
SST39VF6401B / SST39VF6402B
Not Recommended for New Designs
Product Description
The SST39VF640xB devices are 4M x16 CMOS Multi-Purpose Flash Plus (MPF+) manufactured with
proprietary, high-performance CMOS SuperFlash technology. The split-gate cell design and thickoxide tunneling injector attain better reliability and manufacturability compared with alternate
approaches. The SST39VF640xB write (Program or Erase) with a 2.7-3.6V power supply. These
devices conform to JEDEC standard pin assignments for x16 memories.
Featuring high performance Word-Program, the SST39VF640xB devices provide a typical Word-Program time of 7 µsec. These devices use Toggle Bit or Data# Polling to indicate the completion of
Program operation. To protect against inadvertent write, they have on-chip hardware and Software
Data Protection schemes. Designed, manufactured, and tested for a wide spectrum of applications,
these devices are offered with a guaranteed typical endurance of 100,000 cycles. Data retention is
rated at greater than 100 years.
The SST39VF640xB devices are suited for applications that require convenient and economical updating of program, configuration, or data memory. For all system applications, they significantly improve
performance and reliability, while lowering power consumption. They inherently use less energy during
Erase and Program than alternative flash technologies. The total energy consumed is a function of the
applied voltage, current, and time of application. Since for any given voltage range, the SuperFlash
technology uses less current to program and has a shorter erase time, the total energy consumed
during any Erase or Program operation is less than alternative flash technologies. These devices also
improve flexibility while lowering the cost for program, data, and configuration storage applications.
The SuperFlash technology provides fixed Erase and Program times, independent of the number of
Erase/Program cycles that have occurred. Therefore the system software or hardware does not have
to be modified or de-rated as is necessary with alternative flash technologies, whose Erase and Program times increase with accumulated Erase/Program cycles.
To meet high-density, surface mount requirements, the SST39VF640xB devices are offered in 48-lead
TSOP and 48-ball TFBGA packages. See Figures 22 and 3 for pin assignments.
©2015-2018
2
DS20005008C
64 Mbit Multi-Purpose Flash Plus
SST39VF6401B / SST39VF6402B
Not Recommended for New Designs
Block Diagram
X-Decoder
Memory Address
SuperFlash
Memory
Address Buffer & Latches
Y-Decoder
CE#
OE#
WE#
WP#
RESET#
I/O Buffers and Data Latches
Control Logic
DQ15 - DQ0
1288 B1.0
Figure 1: Block Diagram
©2015-2018
3
DS20005008C
64 Mbit Multi-Purpose Flash Plus
SST39VF6401B / SST39VF6402B
Not Recommended for New Designs
Pin Assignments
A15
A14
A13
A12
A11
A10
A9
A8
A19
A20
WE#
RST#
A21
WP#
NC
A18
A17
A7
A6
A5
A4
A3
A2
A1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
A16
NC
VSS
DQ15
DQ7
DQ14
DQ6
DQ13
DQ5
DQ12
DQ4
VDD
DQ11
DQ3
DQ10
DQ2
DQ9
DQ1
DQ8
DQ0
OE#
VSS
CE#
A0
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
Standard Pinout
Top View
Die Up
1288 48-tsop P1.0
Figure 2: Pin Assignments for 48-lead TSOP
6
5
4
3
2
1
A13 A12 A14
A15 A16 NC DQ15 VSS
A9
A10
A11 DQ7 DQ14 DQ13 DQ6
WE# RST# A21
A19 DQ5 DQ12 VDD DQ4
NC WP# A18
A20 DQ2 DQ10 DQ11 DQ3
A7
A17
A6
A5
DQ0 DQ8 DQ9 DQ1
A3
A4
A2
A1
A0 CE# OE# VSS
A8
A B C D E F G H
1288 4-tfbga B1K P2.0
TOP VIEW (balls facing down)
Figure 3: Pin assignments for 48-ball TFBGA
©2015-2018
4
DS20005008C
64 Mbit Multi-Purpose Flash Plus
SST39VF6401B / SST39VF6402B
Not Recommended for New Designs
Table 1: Pin Description
Symbol
Pin Name
Functions
AMS1-A0
Address Inputs
To provide memory addresses.
During Sector-Erase AMS-A11 address lines will select the sector.
During Block-Erase AMS-A15 address lines will select the block.
DQ15-DQ0
Data Input/output To output data during Read cycles and receive input data during Write cycles.
Data is internally latched during a Write cycle.
The outputs are in tri-state when OE# or CE# is high.
WP#
Write Protect
To protect the top/bottom boot block from Erase/Program operation when
grounded.
RST#
Reset
To reset and return the device to Read mode.
CE#
Chip Enable
To activate the device when CE# is low.
OE#
Output Enable
To gate the data output buffers.
WE#
Write Enable
To control the Write operations.
VDD
Power Supply
To provide power supply voltage: 2.7-3.6V
VSS
Ground
NC
No Connection
Unconnected pins.
T1.0 25008
1. AMS = Most significant address
AMS = A21 for SST39VF640xB
©2015-2018
5
DS20005008C
64 Mbit Multi-Purpose Flash Plus
SST39VF6401B / SST39VF6402B
Not Recommended for New Designs
Device Operation
Commands are used to initiate the memory operation functions of the device. Commands are written
to the device using standard microprocessor write sequences. A command is written by asserting WE#
low while keeping CE# low. The address bus is latched on the falling edge of WE# or CE#, whichever
occurs last. The data bus is latched on the rising edge of WE# or CE#, whichever occurs first.
The SST39VF640xB also have the Auto Low Power mode which puts the device in a near standby
mode after data has been accessed with a valid Read operation. This reduces the IDD active read current from typically 9 mA to typically 3 µA. The Auto Low Power mode reduces the typical IDD active
read current to the range of 2 mA/MHz of Read cycle time. The device exits the Auto Low Power mode
with any address transition or control signal transition used to initiate another Read cycle, with no
access time penalty. Note that the device does not enter Auto Low Power mode after power-up with
CE# held steadily low, until the first address transition or CE# is driven high.
Read
The Read operation of the SST39VF640xB is controlled by CE# and OE#, both have to be low for the
system to obtain data from the outputs. CE# is used for device selection. When CE# is high, the chip is
deselected and only standby power is consumed. OE# is the output control and is used to gate data
from the output pins. The data bus is in high impedance state when either CE# or OE# is high. Refer to
the Read cycle timing diagram for further details (Figure 4).
Word-Program Operation
The SST39VF640xB are programmed on a word-by-word basis. Before programming, the sector
where the word exists must be fully erased. The Program operation is accomplished in three steps.
The first step is the three-byte load sequence for Software Data Protection. The second step is to load
word address and word data. During the Word-Program operation, the addresses are latched on the
falling edge of either CE# or WE#, whichever occurs last. The data is latched on the rising edge of
either CE# or WE#, whichever occurs first. The third step is the internal Program operation which is initiated after the rising edge of the fourth WE# or CE#, whichever occurs first. The Program operation,
once initiated, will be completed within 10 µs. See Figures 5 and 6 for WE# and CE# controlled Program operation timing diagrams and Figure 20 for flowcharts. During the Program operation, the only
valid reads are Data# Polling and Toggle Bit. During the internal Program operation, the host is free to
perform additional tasks. Any commands issued during the internal Program operation are ignored.
During the command sequence, WP# should be statically held high or low.
Sector/Block-Erase Operation
The Sector- (or Block-) Erase operation allows the system to erase the device on a sector-by-sector
(or block-by-block) basis. The SST39VF640xB offer both Sector-Erase and Block-Erase mode. The
sector architecture is based on uniform sector size of 2 KWord. The Block-Erase mode is based on
uniform block size of 32 KWord. The Sector-Erase operation is initiated by executing a six-byte command sequence with Sector-Erase command (50H) and sector address (SA) in the last bus cycle. The
Block-Erase operation is initiated by executing a six-byte command sequence with Block-Erase command (30H) and block address (BA) in the last bus cycle. The sector or block address is latched on the
falling edge of the sixth WE# pulse, while the command (50H or 30H) is latched on the rising edge of
the sixth WE# pulse. The internal Erase operation begins after the sixth WE# pulse. The End-of-Erase
operation can be determined using either Data# Polling or Toggle Bit methods. See Figures 10 and 11
©2015-2018
6
DS20005008C
64 Mbit Multi-Purpose Flash Plus
SST39VF6401B / SST39VF6402B
Not Recommended for New Designs
for timing waveforms and Figure 24 for the flowchart. Any commands issued during the Sector- or
Block-Erase operation are ignored. When WP# is low, any attempt to Sector- (Block-) Erase the protected block will be ignored. During the command sequence, WP# should be statically held high or low.
Erase-Suspend/Erase-Resume Commands
The Erase-Suspend operation temporarily suspends a Sector- or Block-Erase operation thus allowing
data to be read from any memory location, or program data into any sector/block that is not suspended
for an Erase operation. The operation is executed by issuing one byte command sequence with EraseSuspend command (B0H). The device automatically enters read mode typically within 20 µs after the
Erase-Suspend command had been issued. Valid data can be read from any sector or block that is not
suspended from an Erase operation. Reading at address location within erase-suspended sectors/
blocks will output DQ2 toggling and DQ6 at “1”. While in Erase-Suspend mode, a Word-Program operation is allowed except for the sector or block selected for Erase-Suspend.
To resume Sector-Erase or Block-Erase operation which has been suspended the system must issue
Erase Resume command. The operation is executed by issuing one byte command sequence with
Erase Resume command (30H) at any address in the last Byte sequence.
Chip-Erase Operation
The SST39VF640xB provide a Chip-Erase operation, which allows the user to erase the entire memory array to the “1” state. This is useful when the entire device must be quickly erased.
The Chip-Erase operation is initiated by executing a six-byte command sequence with Chip-Erase
command (10H) at address 555H in the last byte sequence. The Erase operation begins with the rising
edge of the sixth WE# or CE#, whichever occurs first. During the Erase operation, the only valid read is
Toggle Bit or Data# Polling. See Table 6 for the command sequence, Figure 10 for timing diagram, and
Figure 24 for the flowchart. Any commands issued during the Chip-Erase operation are ignored. When
WP# is low, any attempt to Chip-Erase will be ignored. During the command sequence, WP# should
be statically held high or low.
Write Operation Status Detection
The SST39VF640xB provide two software means to detect the completion of a Write (Program or
Erase) cycle, in order to optimize the system write cycle time. The software detection includes two status bits: Data# Polling (DQ7) and Toggle Bit (DQ6). The End-of-Write detection mode is enabled after
the rising edge of WE#, which initiates the internal Program or Erase operation.
The actual completion of the nonvolatile write is asynchronous with the system; therefore, either a
Data# Polling or Toggle Bit read may be simultaneous with the completion of the write cycle. If this
occurs, the system may possibly get an erroneous result, i.e., valid data may appear to conflict with
either DQ7 or DQ6. In order to prevent spurious rejection, if an erroneous result occurs, the software
routine should include a loop to read the accessed location an additional two (2) times. If both reads
are valid, then the device has completed the Write cycle, otherwise the rejection is valid.
©2015-2018
7
DS20005008C
64 Mbit Multi-Purpose Flash Plus
SST39VF6401B / SST39VF6402B
Not Recommended for New Designs
Data# Polling (DQ7)
When the SST39VF640xB are in the internal Program operation, any attempt to read DQ7 will produce
the complement of the true data. Once the Program operation is completed, DQ7 will produce true
data. Note that even though DQ7 may have valid data immediately following the completion of an internal Write
operation, the remaining data outputs may still be invalid: valid data on the entire data bus will appear in subsequent successive Read cycles after an interval of 1 µs. During internal Erase operation, any attempt to read
DQ7 will produce a ‘0’. Once the internal Erase operation is completed, DQ7 will produce a ‘1’. The
Data# Polling is valid after the rising edge of fourth WE# (or CE#) pulse for Program operation. For
Sector-, Block- or Chip-Erase, the Data# Polling is valid after the rising edge of sixth WE# (or CE#)
pulse. See Figure 7 for Data# Polling timing diagram and Figure 21 for a flowchart.
Toggle Bits (DQ6 and DQ2)
During the internal Program or Erase operation, any consecutive attempts to read DQ6 will produce
alternating “1”s and “0”s, i.e., toggling between 1 and 0. When the internal Program or Erase operation
is completed, the DQ6 bit will stop toggling. The device is then ready for the next operation. For Sector, Block-, or Chip-Erase, the toggle bit (DQ6) is valid after the rising edge of sixth WE# (or CE#) pulse.
DQ6 will be set to “1” if a Read operation is attempted on an Erase-Suspended Sector/Block. If Program operation is initiated in a sector/block not selected in Erase-Suspend mode, DQ6 will toggle.
An additional Toggle Bit is available on DQ2, which can be used in conjunction with DQ6 to check
whether a particular sector is being actively erased or erase-suspended. Table 2 shows detailed status
bits information. The Toggle Bit (DQ2) is valid after the rising edge of the last WE# (or CE#) pulse of
Write operation. See Figure 8 for Toggle Bit timing diagram and Figure 21 for a flowchart.
Table 2: Write Operation Status
Status
Normal Operation
Erase-Suspend
Mode
DQ7
DQ6
DQ2
DQ7#
Toggle
No Toggle
Standard Erase
0
Toggle
Toggle
Read from Erase-Suspended Sector/Block
1
1
Toggle
Standard Program
Read from Non- Erase-Suspended Sector/Block
Data
Data
Data
Program
DQ7#
Toggle
N/A
Note: DQ7 and DQ2 require a valid address when reading status information.
©2015-2018
8
T2.0 25008
DS20005008C
64 Mbit Multi-Purpose Flash Plus
SST39VF6401B / SST39VF6402B
Not Recommended for New Designs
Data Protection
The SST39VF640xB provide both hardware and software features to protect nonvolatile data from
inadvertent writes.
Hardware Data Protection
Noise/Glitch Protection: A WE# or CE# pulse of less than 5 ns will not initiate a write cycle.
VDD Power Up/Down Detection: The Write operation is inhibited when VDD is less than 1.5V.
Write Inhibit Mode: Forcing OE# low, CE# high, or WE# high will inhibit the Write operation. This prevents inadvertent writes during power-up or power-down.
Hardware Block Protection
The SST39VF6402B supports top hardware block protection, which protects the top 32 KWord block
of the device. The SST39VF6401B supports bottom hardware block protection, which protects the bottom 32 KWord block of the device. The Boot Block address ranges are described in Table 3. Program
and Erase operations are prevented on the 32 KWord when WP# is low. If WP# is left floating, it is
internally held high via a pull-up resistor, and the Boot Block is unprotected, enabling Program and
Erase operations on that block.
Table 3: Boot Block Address Ranges
Product
Address Range
Bottom Boot Block
SST39VF6401B
000000H-007FFFH
Top Boot Block
SST39VF6402B
3F8000H-3FFFFFH
T3.0 25008
©2015-2018
9
DS20005008C
64 Mbit Multi-Purpose Flash Plus
SST39VF6401B / SST39VF6402B
Not Recommended for New Designs
Hardware Reset (RST#)
The RST# pin provides a hardware method of resetting the device to read array data. When the RST#
pin is held low for at least TRP, any in-progress operation will terminate and return to Read mode.
When no internal Program/Erase operation is in progress, a minimum period of TRHR is required after
RST# is driven high before a valid Read can take place (see Figure 16).
The Erase or Program operation that has been interrupted needs to be reinitiated after the device
resumes normal operation mode to ensure data integrity.
Software Data Protection (SDP)
The SST39VF640xB provide the JEDEC approved Software Data Protection scheme for all data alteration operations, i.e., Program and Erase. Any Program operation requires the inclusion of the threebyte sequence. The three-byte load sequence is used to initiate the Program operation, providing optimal protection from inadvertent Write operations, e.g., during the system power-up or power-down.
Any Erase operation requires the inclusion of six-byte sequence. These devices are shipped with the
Software Data Protection permanently enabled. See Table 6 for the specific software command codes.
During SDP command sequence, invalid commands will abort the device to read mode within TRC. The
contents of DQ15-DQ8 can be VIL or VIH, but no other value, during any SDP command sequence.
Common Flash Memory Interface (CFI)
The SST39VF640xB also contain the CFI information to describe the characteristics of the device. In
order to enter the CFI Query mode, the system must write three-byte sequence, same as product ID
entry command with 98H (CFI Query command) to address 555H in the last byte sequence. Once the
device enters the CFI Query mode, the system can read CFI data at the addresses given in Tables 7
through 9. The system must write the CFI Exit command to return to Read mode from the CFI Query
mode.
©2015-2018
10
DS20005008C
64 Mbit Multi-Purpose Flash Plus
SST39VF6401B / SST39VF6402B
Not Recommended for New Designs
Product Identification
The Product Identification mode identifies the devices as the SST39VF6401B and SST39VF6402B,
and the manufacturer as SST. This mode may be accessed through software operations. Users may
use the Software Product Identification operation to identify the part (i.e., using the device ID) when
using multiple manufacturers in the same socket. For details, see Table 6 for software operation, Figure 12 for the Software ID Entry and Read timing diagram and Figure 22 for the Software ID Entry
command sequence flowchart.
Table 4: Product Identification
Address
Data
0000H
BFH
SST39VF6401B
0001H
236DH
SST39VF6402B
0001H
236CH
Manufacturer’s ID
Device ID
T4.0 25008
Product Identification Mode Exit/CFI Mode Exit
In order to return to the standard Read mode, the Software Product Identification mode must be exited.
Exit is accomplished by issuing the Software ID Exit command sequence, which returns the device to
the Read mode. This command may also be used to reset the device to the Read mode after any inadvertent transient condition that apparently causes the device to behave abnormally, e.g., not read correctly. Please note that the Software ID Exit/CFI Exit command is ignored during an internal Program
or Erase operation. See Table 6 for software command codes, Figure 14 for timing waveform, and Figures 22 and 23 for flowcharts.
©2015-2018
11
DS20005008C
64 Mbit Multi-Purpose Flash Plus
SST39VF6401B / SST39VF6402B
Not Recommended for New Designs
Security ID
The SST39VF640xB devices offer a 256-bit Security ID space. The Secure ID space is divided into
two 128-bit segments - one factory programmed segment and one user programmed segment. The
first segment is programmed and locked at Microchip with a random 128-bit number. The user segment is left unprogrammed for the customer to program as desired.
To program the user segment of the Security ID, the user must use the Security ID Word-Program
command. To detect end-of-write for the SEC ID, read the toggle bits. Do not use Data# Polling. Once
this is complete, the Sec ID should be locked using the User Sec ID Program Lock-Out. This disables
any future corruption of this space. Note that regardless of whether or not the Sec ID is locked, neither
Sec ID segment can be erased.
The Secure ID space can be queried by executing a three-byte command sequence with Enter Sec ID
command (88H) at address 555H in the last byte sequence. To exit this mode, the Exit Sec ID command should be executed. Refer to Table 6 for more details.
©2015-2018
12
DS20005008C
64 Mbit Multi-Purpose Flash Plus
SST39VF6401B / SST39VF6402B
Not Recommended for New Designs
Operations
Table 5: Operation Modes Selection
Mode
CE#
OE#
WE#
Read
Program
VIL
VIL
VIL
VIH
Address
VIH
DOUT
AIN
VIL
DIN
AIN
VIL
X1
Sector or block address,
XXH for Chip-Erase
Erase
VIL
Standby
VIH
X
X
High Z
X
X
VIL
X
High Z/ DOUT
X
X
X
VIH
High Z/ DOUT
X
VIL
VIL
VIH
Write Inhibit
VIH
DQ
Product Identification
Software Mode
See Table 6
T5.0 25008
1. X can be VIL or VIH, but no other value.
Table 6:
Software Command Sequence
Command
Sequence
1st Bus
Write Cycle
Addr1
Data2
2nd Bus
Write Cycle
Addr1
3rd Bus
Write Cycle
4th Bus
Write Cycle
Data2 Addr1 Data2 Addr1
Word-Program
555H
AAH
2AAH
55H
555H
A0H
WA3
Sector-Erase
555H
AAH
2AAH
55H
555H
80H
555H
Data2
Data
AAH
5th Bus
Write Cycle
Addr1
2AAH
6th Bus
Write Cycle
Data2 Addr1 Data2
55H
SAX4
30H
10H
Block-Erase
555H
AAH
2AAH
55H
555H
80H
555H
AAH
2AAH
55H
BAX4
Chip-Erase
555H
AAH
2AAH
55H
555H
80H
555H
AAH
2AAH
55H
555H
Erase-Suspend
XXXXH
B0H
Erase-Resume
XXXXH
30H
Query Sec ID5
555H
AAH
2AAH
55H
555H
88H
User Security ID
Word-Program
555H
AAH
2AAH
55H
555H
A5H
WA6
Data
User Security ID
Program Lock-Out
555H
AAH
2AAH
55H
555H
85H
XXH6
0000H
Software ID Entry7,8
555H
AAH
2AAH
55H
555H
90H
CFI Query Entry
555H
AAH
2AAH
55H
555H
98H
Software ID Exit9,10
/CFI Exit/Sec ID Exit
555H
AAH
2AAH
55H
555H
F0H
Software ID Exit9,10
/CFI Exit/Sec ID Exit
XXH
F0H
1. Address format A10-A0 (Hex).
Addresses A11- A21 can be VIL or VIH, but no other value, for Command sequence for SST39VF640xB.
2. DQ15-DQ8 can be VIL or VIH, but no other value, for Command sequence
3. WA = Program Word address
4. SAX for Sector-Erase; uses AMS-A11 address lines
BAX, for Block-Erase; uses AMS-A15 address lines
AMS = Most significant address
AMS = A21 for SST39VF640xB
5. With AMS-A4 = 0; Sec ID is read with A3-A0,
SST ID is read with A3 = 0 (Address range = 000000H to 000007H),
User ID is read with A3 = 1 (Address range = 000010H to 000017H).
Lock Status is read with A7-A0 = 0000FFH. Unlocked: DQ3 = 1 / Locked: DQ3 = 0.
6. Valid Word-Addresses for Sec ID are from 000000H-000007H and 000010H-000017H.
©2015-2018
13
DS20005008C
50H
T6.0 25008
64 Mbit Multi-Purpose Flash Plus
SST39VF6401B / SST39VF6402B
Not Recommended for New Designs
7. The device does not remain in Software Product ID Mode if powered down.
8. With AMS-A1 =0; Manufacturer ID = 00BFH, is read with A0 = 0,
SST39VF6401B Device ID = 236DH, is read with A0 = 1,
SST39VF6402B Device ID = 236CH, is read with A0 = 1.
AMS = Most significant address
AMS = A21 for SST39VF640xB
9. Both Software ID Exit operations are equivalent
10. If users never lock after programming, Sec ID can be programmed over the previously unprogrammed bits (data=1)
using the Sec ID mode again (the programmed “0” bits cannot be reversed to “1”). Valid Word-Addresses for Sec ID are
from 000000H-000007H and 000010H-000017H.
Table 7: CFI Query Identification String1 for SST39VF640xB
Address
Data
10H
0051H
11H
0052H
12H
0059H
13H
0002H
14H
0000H
15H
0000H
16H
0000H
17H
0000H
18H
0000H
19H
0000H
1AH
0000H
Data
Query Unique ASCII string “QRY”
Primary OEM command set
Address for Primary Extended Table
Alternate OEM command set (00H = none exists)
Address for Alternate OEM extended Table (00H = none exits)
T7.0 25008
1. Refer to CFI publication 100 for more details.
Table 8: System Interface Information for SST39VF640xB
Address
Data
1BH
0027H
Data
VDD Min (Program/Erase)
DQ7-DQ4: Volts, DQ3-DQ0: 100 millivolts
1CH
0036H
VDD Max (Program/Erase)
DQ7-DQ4: Volts, DQ3-DQ0: 100 millivolts
1DH
0000H
VPP min. (00H = no VPP pin)
1EH
0000H
VPP max. (00H = no VPP pin)
1FH
0003H
Typical time out for Word-Program 2N µs (23 = 8 µs)
20H
0000H
Typical time out for min. size buffer program 2N µs (00H = not supported)
21H
0004H
Typical time out for individual Sector/Block-Erase 2N ms (24 = 16 ms)
22H
0005H
Typical time out for Chip-Erase 2N ms (25 = 32 ms)
23H
0001H
Maximum time out for Word-Program 2N times typical (21 x 23 = 16 µs)
24H
0000H
Maximum time out for buffer program 2N times typical
25H
0001H
Maximum time out for individual Sector/Block-Erase 2N times typical (21 x 24 = 32 ms)
26H
0001H
Maximum time out for Chip-Erase 2N times typical (21 x 25 = 64 ms)
T8.0 25008
©2015-2018
14
DS20005008C
64 Mbit Multi-Purpose Flash Plus
SST39VF6401B / SST39VF6402B
Not Recommended for New Designs
Table 9: Device Geometry Information for SST39VF640xB
Address
Data
27H
0017H
Data
Device size = 2N Bytes (17H = 23; 223 = 8 MByte)
28H
0001H
Flash Device Interface description; 0001H = x16-only asynchronous interface
29H
0000H
2AH
0000H
2BH
0000H
Maximum number of bytes in multi-byte write = 2N (00H = not supported)
2CH
0002H
Number of Erase Sector/Block sizes supported by device
2DH
00FFH
Sector Information (y + 1 = Number of sectors; z x 256B = sector size)
2EH
0007H
y = 2047 + 1 = 2048 sectors (07FFH = 2047)
2FH
0010H
30H
0000H
z = 16 x 256 Bytes = 4 KBytes/sector (0010H = 16)
31H
007FH
Block Information (y + 1 = Number of blocks; z x 256B = block size)
32H
0000H
y =127 + 1 = 128 blocks (007FH = 127)
33H
0000H
34H
0001H
z = 256 x 256 Bytes = 64 KBytes/block (0100H = 256)
T9.0 25008
©2015-2018
15
DS20005008C
64 Mbit Multi-Purpose Flash Plus
SST39VF6401B / SST39VF6402B
Not Recommended for New Designs
Absolute Maximum Stress Ratings (Applied conditions greater than those listed under “Absolute
Maximum Stress Ratings” may cause permanent damage to the device. This is a stress rating only and
functional operation of the device at these conditions or conditions greater than those defined in the
operational sections of this data sheet is not implied. Exposure to absolute maximum stress rating conditions may affect device reliability.)
Temperature Under Bias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -55°C to +125°C
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -65°C to +150°C
D. C. Voltage on Any Pin to Ground Potential . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5V to VDD+0.5V
Transient Voltage (