VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02
Datasheet
Family of L2/L3 Enterprise Gigabit Ethernet Switches
with 10 Gbps Links
Microsemi Headquarters
One Enterprise, Aliso Viejo,
CA 92656 USA
Within the USA: +1 (800) 713-4113
Outside the USA: +1 (949) 380-6100
Sales: +1 (949) 380-6136
Fax: +1 (949) 215-4996
Email: sales.support@microsemi.com
www.microsemi.com
©2018 Microsemi, a wholly owned
subsidiary of Microchip Technology Inc. All
rights reserved. Microsemi and the
Microsemi logo are registered trademarks of
Microsemi Corporation. All other trademarks
and service marks are the property of their
respective owners.
Microsemi makes no warranty, representation, or guarantee regarding the information contained herein or the suitability of
its products and services for any particular purpose, nor does Microsemi assume any liability whatsoever arising out of the
application or use of any product or circuit. The products sold hereunder and any other products sold by Microsemi have
been subject to limited testing and should not be used in conjunction with mission-critical equipment or applications. Any
performance specifications are believed to be reliable but are not verified, and Buyer must conduct and complete all
performance and other testing of the products, alone and together with, or installed in, any end-products. Buyer shall not
rely on any data and performance specifications or parameters provided by Microsemi. It is the Buyer’s responsibility to
independently determine suitability of any products and to test and verify the same. The information provided by Microsemi
hereunder is provided “as is, where is” and with all faults, and the entire risk associated with such information is entirely
with the Buyer. Microsemi does not grant, explicitly or implicitly, to any party any patent rights, licenses, or any other IP
rights, whether with regard to such information itself or anything described by such information. Information provided in this
document is proprietary to Microsemi, and Microsemi reserves the right to make any changes to the information in this
document or to any products and services at any time without notice.
About Microsemi
Microsemi, a wholly owned subsidiary of Microchip Technology Inc. (Nasdaq: MCHP), offers a comprehensive portfolio of
semiconductor and system solutions for aerospace & defense, communications, data center and industrial markets.
Products include high-performance and radiation-hardened analog mixed-signal integrated circuits, FPGAs, SoCs and
ASICs; power management products; timing and synchronization devices and precise time solutions, setting the world's
standard for time; voice processing devices; RF solutions; discrete components; enterprise storage and communication
solutions, security technologies and scalable anti-tamper products; Ethernet solutions; Power-over-Ethernet ICs and
midspans; as well as custom design capabilities and services. Learn more at www.microsemi.com.
VMDS-10498. 4.1 3/19
Contents
1 Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.1
1.2
Revision 4.1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Revision 4.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2 Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
General Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Layer 2 and Layer 3 Forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Timing and Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Quality of Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Product Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Functional Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.9.1
Frame Arrival in Ports and Port Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.9.2
Basic Classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.9.3
Security and Control Protocol Classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.9.4
Policing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.9.5
Layer 2 Forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.9.6
Layer 3 Forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.9.7
Shared Queue System and Hierarchical Scheduler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.9.8
Rewriter and Frame Departure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.9.9
CPU Port Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.9.10 Synchronous Ethernet and Precision Time Protocol (PTP) . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3 Functional Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8
Register Notations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Frame Headers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2.1
Internal Frame Header Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2.2
Internal Frame Header Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2.3
VStaX Header . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Port Numbering and Mappings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.3.1
SERDES Macro to I/O Pin Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.3.2
Supported Port Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.3.3
QSGMII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.3.4
10G Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.3.5
VSC7442-02 Port Numbering and Port Mappings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.3.6
VSC7444-02 Port Numbering and Port Mappings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.3.7
VSC7448-02 Port Numbering and Port Mappings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.3.8
VSC7449-02 Port Numbering and Port Mappings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.3.9
Logical Port Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SERDES1G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SERDES6G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SERDES10G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DEV1G and DEV2G5 Port Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.7.1
MAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.7.2
Half-Duplex Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.7.3
Physical Coding Sublayer (PCS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.7.4
Port Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DEV10G Port Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
14
14
15
15
21
25
27
27
28
30
32
33
33
34
35
35
35
36
36
36
38
39
42
42
iii
3.9
3.10
3.11
3.12
3.13
3.14
3.15
3.16
3.17
3.18
3.19
3.20
3.8.1
MAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
3.8.2
Physical Coding Sublayer (PCS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
3.8.3
Port Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Assembler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
3.9.1
Setting Up a Port in the Assembler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
3.9.2
Setting Up a Port for Frame Injection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
3.9.3
Setting Up MAC Control Sublayer PAUSE Frame Detection . . . . . . . . . . . . . . . . . . . . . . . . . 54
3.9.4
Setting Up PFC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
3.9.5
Setting Up Assembler Port Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
3.9.6
Setting Up the Loopback Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Versatile Content-Aware Processor (VCAP™) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
3.10.1 Configuring VCAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
3.10.2 Wide VCAP Entries and Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
3.10.3 Individual VCAPs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
3.10.4 VCAP Programming Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Pipeline Points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
3.11.1 Pipeline Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
3.12.1 Initializing the Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
VCAP CLM Keys and Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
3.13.1 Keys Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
3.13.2 VCAP CLM X1 Key Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
3.13.3 VCAP CLM X2 Key Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
3.13.4 VCAP CLM X4 Key Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
3.13.5 VCAP CLM X8 Key Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
3.13.6 VCAP CLM X16 Key Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
3.13.7 VCAP CLM Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Analyzer Classifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
3.14.1 Basic Classifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
3.14.2 VCAP CLM Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
3.14.3 QoS Mapping Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
3.14.4 Analyzer Classifier Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
VLAN and MSTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
3.15.1 Private VLAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
3.15.2 VLAN Pseudo Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
VCAP LPM: Keys and Action . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
3.16.1 VCAP LPM SGL_IP4 Key Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
3.16.2 VCAP LPM DBL_IP4 Key Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
3.16.3 VCAP LPM SGL_IP6 Key Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
3.16.4 VCAP LPM DBL_IP6 Key Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
3.16.5 VCAP LPM Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
IP Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
3.17.1 IP Source/Destination Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
3.17.2 IP Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
3.17.3 Frame Types for IP Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
3.17.4 Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
3.17.5 IGMP/MLD Snooping Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
VCAP IS2 Keys and Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
3.18.1 VCAP IS2 Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
3.18.2 VCAP IS2 Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
Analyzer Access Control Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
3.19.1 VCAP IS2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
3.19.2 Analyzer Access Control List Frame Rewriting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
Analyzer Layer 2 Forwarding and Learning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
3.20.1 Analyzer MAC Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
3.20.2 MAC Table Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
iv
3.21
3.22
3.23
3.24
3.25
3.26
3.20.3 CPU Access to MAC Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
3.20.4 SCAN Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174
3.20.5 Forwarding Lookups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176
3.20.6 Source Check and Automated Learning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
3.20.7 Automated Aging (AUTOAGE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
3.20.8 Interrupt Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
Analyzer Access Control Forwarding, Policing, and Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
3.21.1 Mask Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
3.21.2 Policing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
3.21.3 Analyzer Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
3.21.4 Analyzer sFlow Sampling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
3.21.5 Mirroring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
Shared Queue System and Hierarchical Scheduler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
3.22.1 Analyzer Result . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
3.22.2 Buffer Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
3.22.3 Forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
3.22.4 Congestion Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
3.22.5 Queue Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
3.22.6 Queue Congestion Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
3.22.7 Scheduling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224
3.22.8 Queue System Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228
3.22.9 Miscellaneous Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228
Automatic Frame Injector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232
3.23.1 Injection Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232
3.23.2 Frame Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233
3.23.3 Delay Triggered Injection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
3.23.4 Timer Triggered Injection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238
3.23.5 Injection Queues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244
3.23.6 Adding Injection Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244
3.23.7 Starting Injection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
3.23.8 Stopping Injection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
3.23.9 Removing Injection Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
3.23.10 Port Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
Rewriter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
3.24.1 Rewriter Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
3.24.2 Supported Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
3.24.3 Supported Frame Formats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
3.24.4 Rewriter Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
3.24.5 VCAP_ES0 Lookup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
3.24.6 Mapping Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258
3.24.7 VLAN Editing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260
3.24.8 DSCP Remarking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265
3.24.9 VStaX Header Insertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266
3.24.10 Forwarding to GCPU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266
3.24.11 Layer 3 Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268
3.24.12 Mirror Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268
3.24.13 Internal Frame Header Insertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269
3.24.14 Frame Injection from Internal CPU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270
Disassembler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271
3.25.1 Setting Up Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271
3.25.2 Maintaining the Cell Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271
3.25.3 Setting Up MAC Control Sublayer PAUSE Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272
3.25.4 Setting up Flow Control in Half-Duplex Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273
3.25.5 Setting Up Frame Aging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273
3.25.6 Setting Up Transmit Data Rate Limiting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274
3.25.7 Error Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276
Layer 1 Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
v
3.27
3.28
3.29
3.30
3.31
3.32
3.33
3.34
Hardware Time Stamping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
3.27.1 One-Step Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283
3.27.2 Calculation Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
3.27.3 Detecting Calculation Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
3.27.4 Two-Step Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
3.27.5 Time of Day Time Stamping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285
3.27.6 Time of Day Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285
3.27.7 Multiple PTP Time Domains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287
3.27.8 Register Interface to 1588 Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287
3.27.9 Configuring I/O Delays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289
VRAP Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289
3.28.1 VRAP Request Frame Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290
3.28.2 VRAP Response Frame Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
3.28.3 VRAP Header Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
3.28.4 VRAP READ Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
3.28.5 VRAP READ-MODIFY-WRITE Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292
3.28.6 VRAP IDLE Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292
3.28.7 VRAP PAUSE Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292
Energy Efficient Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293
CPU Injection and Extraction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
3.30.1 Frame Injection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
3.30.2 Frame Extraction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
3.30.3 Forwarding to CPU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
3.30.4 Automatic Frame Injection (AFI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
Priority-Based Flow Control (PFC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
3.31.1 PFC Pause Frame Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296
3.31.2 PFC Frame Reception . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 297
Protection Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 297
3.32.1 Ethernet Ring Protection Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 297
3.32.2 Link Aggregation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
3.32.3 Port Protection Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
High-Speed Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301
3.33.1 One-Time Configurations for High-Speed Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301
Clocking and Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301
3.34.1 Pin Strapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302
4 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304
5 VCore-III System and CPU Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 305
5.1
5.2
5.3
5.4
5.5
VCore-III Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306
Clocking and Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307
5.2.1
Watchdog Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307
Shared Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 308
5.3.1
VCore-III Shared Bus Arbitration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310
5.3.2
Chip Register Region . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310
5.3.3
SI Flash Region . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311
5.3.4
DDR3/DDR3L Region . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312
5.3.5
PCIe Region . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312
VCore-III CPU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312
5.4.1
Little Endian and Big Endian Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312
5.4.2
Software Debug and Development . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312
External CPU Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312
5.5.1
Register Access and Multimaster Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313
5.5.2
Serial Interface in Slave Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313
5.5.3
MIIM Interface in Slave Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316
5.5.4
Access to the VCore Shared Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
vi
5.6
5.7
5.8
5.5.5
Mailbox and Semaphores . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 319
PCIe Endpoint Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 320
5.6.1
Accessing Endpoint Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 320
5.6.2
Enabling the Endpoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 320
5.6.3
Base Address Registers Inbound Requests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322
5.6.4
Outbound Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322
5.6.5
Outbound Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323
5.6.6
Power Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325
5.6.7
Device Reset Using PCIe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326
Frame DMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326
5.7.1
DMA Control Block Structures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 327
5.7.2
Enabling and Disabling FDMA Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328
5.7.3
Channel Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 329
5.7.4
FDMA Events and Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 330
5.7.5
FDMA Extraction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331
5.7.6
FDMA Injection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331
5.7.7
Manual Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332
VCore-III System Peripherals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334
5.8.1
SI Boot Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334
5.8.2
SI Master Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 336
5.8.3
DDR3/DDR3L Memory Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341
5.8.4
Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 346
5.8.5
UARTs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347
5.8.6
Two-Wire Serial Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 349
5.8.7
MII Management Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351
5.8.8
GPIO Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 353
5.8.9
Serial GPIO Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 357
5.8.10 Fan Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362
5.8.11 Temperature Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364
5.8.12 Memory Integrity Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364
5.8.13 Interrupt Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 367
6 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
6.1
6.2
DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
6.1.1
Internal Pull-Up or Pull-Down Resistors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
6.1.2
Reference Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
6.1.3
Clock Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
6.1.4
DDR3/DDR3L SDRAM Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374
6.1.5
SERDES1G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375
6.1.6
SERDES6G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375
6.1.7
SERDES10G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 376
6.1.8
GPIO, SI, JTAG, and Miscellaneous Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377
6.1.9
MII Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 378
6.1.10 Recovered Clock Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 378
6.1.11 Thermal Diode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 379
AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 379
6.2.1
Reference Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 379
6.2.2
Clock Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 382
6.2.3
SERDES1G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 382
6.2.4
SERDES6G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384
6.2.5
SERDES10G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 390
6.2.6
Reset Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 395
6.2.7
MII Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 395
6.2.8
Serial Interface (SI) Boot Master Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 396
6.2.9
Serial Interface (SI) Master Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397
6.2.10 Serial Interface (SI) for Slave Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 398
6.2.11 DDR SDRAM Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 399
6.2.12 JTAG Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 401
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
vii
6.3
6.4
6.5
6.2.13 Serial Inputs/Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.2.14 Recovered Clock Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.2.15 Two-Wire Serial Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.2.16 IEEE 1588 Time Tick Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Current and Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.3.1
Current Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.3.2
Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.3.3
Power Supply Sequencing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stress Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
403
403
404
405
406
406
408
409
409
410
7 Pin Descriptions for VSC7442-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 411
7.1
7.2
7.3
7.4
Pin Diagram for VSC7442-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 411
Pins by Function for VSC7442-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 412
7.2.1
DDR SDRAM Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 413
7.2.2
General-Purpose Inputs and Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414
7.2.3
JTAG Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414
7.2.4
MII Management Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414
7.2.5
Miscellaneous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415
7.2.6
PCI Express Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415
7.2.7
Power Supplies and Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 416
7.2.8
SERDES1G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 416
7.2.9
SERDES6G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 416
7.2.10 SERDES10G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 418
7.2.11 Serial CPU Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 418
7.2.12 System Clock Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 418
Pins by Number for VSC7442-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 420
Pins by Name for VSC7442-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 426
8 Pin Descriptions for VSC7444-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 432
8.1
8.2
8.3
8.4
Pin Diagram for VSC7444-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 432
Pins by Function for VSC7444-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 433
8.2.1
DDR SDRAM Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 434
8.2.2
General-Purpose Inputs and Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 435
8.2.3
JTAG Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 435
8.2.4
MII Management Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 435
8.2.5
Miscellaneous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 436
8.2.6
PCI Express Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 436
8.2.7
Power Supplies and Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 436
8.2.8
SERDES1G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 437
8.2.9
SERDES6G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 437
8.2.10 SERDES10G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 439
8.2.11 Serial CPU Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 439
8.2.12 System Clock Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 440
Pins by Number for VSC7444-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 442
Pins by Name for VSC7444-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 448
9 Pin Descriptions for VSC7448-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 454
9.1
9.2
Pin Diagram for VSC7448-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 454
Pins by Function for VSC7448-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 455
9.2.1
DDR SDRAM Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 456
9.2.2
General-Purpose Inputs and Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 457
9.2.3
JTAG Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 457
9.2.4
MII Management Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 457
9.2.5
Miscellaneous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 458
9.2.6
PCI Express Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 458
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
viii
9.3
9.4
9.2.7
Power Supplies and Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.2.8
SERDES1G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.2.9
SERDES6G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.2.10 SERDES10G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.2.11 Serial CPU Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.2.12 System Clock Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pins by Number for VSC7448-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pins by Name for VSC7448-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
458
459
459
461
461
462
463
469
10 Pin Descriptions for VSC7449-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 475
10.1
10.2
10.3
10.4
Pin Diagram for VSC7449-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 475
Pins by Function for VSC7449-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 476
10.2.1 DDR SDRAM Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 477
10.2.2 General-Purpose Inputs and Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 478
10.2.3 JTAG Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 478
10.2.4 MII Management Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 478
10.2.5 Miscellaneous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 479
10.2.6 PCI Express Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 479
10.2.7 Power Supplies and Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 479
10.2.8 SERDES1G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 480
10.2.9 SERDES6G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 480
10.2.10 SERDES10G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 482
10.2.11 Serial CPU Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 482
10.2.12 System Clock Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 483
Pins by Number for VSC7449-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 484
Pins by Name for VSC7449-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 490
11 Package Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 496
11.1
11.2
11.3
Package Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 496
Thermal Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 497
Moisture Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 498
12 Design Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 499
12.1
Reference Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 499
12.1.1 Single-Ended REFCLK Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 499
13 Design Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
14 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 501
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
ix
Figures
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Figure 9
Figure 10
Figure 11
Figure 12
Figure 13
Figure 14
Figure 15
Figure 16
Figure 17
Figure 18
Figure 19
Figure 20
Figure 21
Figure 22
Figure 23
Figure 24
Figure 25
Figure 26
Figure 27
Figure 28
Figure 29
Figure 30
Figure 31
Figure 32
Figure 33
Figure 34
Figure 35
Figure 36
Figure 37
Figure 38
Figure 39
Figure 40
Figure 41
Figure 42
Figure 43
Figure 44
Figure 45
Figure 46
Figure 47
Figure 48
Figure 49
Figure 50
Figure 51
Figure 52
Figure 53
Figure 54
VSC7448-02 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Default Scheduler-Shaper Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Physical Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Frame with Internal Frame Header . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Internal Frame Header . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Frame With VStaX Header . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
VStaX Header Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
QSGMII Muxing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
10G Muxing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Frame Injection Formats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
VCAP Cache Layout Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
VCAP Cache Type-Group Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Processing Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
VLAN Acceptance Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Basic QoS Classification Flow Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Basic DP Classification Flow Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
Basic DSCP Classification Flow Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Basic VLAN Classification Flow Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Example of QoS Mappings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
VLAN Table Update Engine (TUPE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
Router Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
Unicast Routing Table Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Multicast Routing Table Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
Ingress Router Leg Lookup Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
Ingress Router Leg MAC Address Matching for Unicast Packets . . . . . . . . . . . . . . . . . . . . . . . . . 136
IP Unicast Routing Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
ARP Pointer Remapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
IP Multicast Routing Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
MAC Table Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
DMAC Lookup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
Source Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
PGID Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
PGID Lookup Decision Forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185
GLAG Port of Exit Calculation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
Port Mask Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
Policer Hierarchy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190
Sticky Events Available as Global Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
Port Statistics Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
Queue Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
BUM Policer Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
ACL Policer Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
Ingress and Egress Routing Statistics per Router Leg per IP Version . . . . . . . . . . . . . . . . . . . . . 203
sFlow Stamp Format in FCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
Ingress Mirroring in Specific VLAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
Shared Queue System Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208
Translation of Transmit Requests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212
Accounting Sheet Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
Reserved and Shared Resource Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
Strict Priority Sharing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
Per Priority Sharing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
WRED Sharing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
WRED Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217
Scheduler Hierarchy (Normal Scheduling Mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
Queue Mapping Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
x
Figure 55
Figure 56
Figure 57
Figure 58
Figure 59
Figure 60
Figure 61
Figure 62
Figure 63
Figure 64
Figure 65
Figure 66
Figure 67
Figure 68
Figure 69
Figure 70
Figure 71
Figure 72
Figure 73
Figure 74
Figure 75
Figure 76
Figure 77
Figure 78
Figure 79
Figure 80
Figure 81
Figure 82
Figure 83
Figure 84
Figure 85
Figure 86
Figure 87
Figure 88
Figure 89
Figure 90
Figure 91
Figure 92
Figure 93
Figure 94
Figure 95
Figure 96
Figure 97
Figure 98
Figure 99
Figure 100
Figure 101
Figure 102
Figure 103
Figure 104
Figure 105
Figure 106
Figure 107
Figure 108
Figure 109
Figure 110
Figure 111
Figure 112
Figure 113
Group Scheduling Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
Mobile Backhaul Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222
Drop Decision Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
Queue Limitation Share . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
Default Scheduling Hierarchy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225
Scheduler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227
Internal Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
Injection Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233
DTI Frame/Delay Sequence Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235
Fine Tuning Bandwidth of DTI Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
Fine Tuning Bandwidth of Multiframe DTI Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
DTI Frame/Delay Sequence Using Inject Forever . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
DTI Concatenation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
TTI Calendar Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
AFI TUPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
Frame Forward Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255
Mapping Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
VLAN Pushing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261
VLAN Tag Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263
Supported KEEP_IFH_SEL Formats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270
Supported Time Stamping Flows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
Frame Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282
Time Stamp Bus and FIFO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285
Timing Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 286
VRAP Request Frame Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290
VRAP Header Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
READ Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
WRITE Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292
READ-MODIFY-WRITE Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292
IDLE Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292
PAUSE Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292
EEE State Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293
PFC Generation per Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296
Ethernet Ring Protection Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298
Ethernet Ring with Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
VCore-III System Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306
Shared Bus Memory Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309
Chip Registers Memory Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311
Write Sequence for SI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314
Read Sequence for SI_CLK Slow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315
Read Sequence for SI_CLK Pause . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315
Read Sequence for One-Byte Padding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315
MIIM Slave Write Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317
MIIM Slave Read Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317
FDMA DCB Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328
FDMA Channel States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 329
FDMA Channel Interrupt Hierarchy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331
Extraction Status Word Encoding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333
Injection Status Word Encoding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334
SI Boot Controller Memory Map in 24-Bit Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 335
SI Boot Controller Memory Map in 32-Bit Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 335
SI Read Timing in Normal Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 336
SI Read Timing in Fast Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 336
SIMC SPI Clock Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 339
SIMC SPI 3x Transfers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 339
Memory Controller ODT Hookup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344
UART Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348
Two-Wire Serial Interface Timing for 7-Bit Address Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350
MII Management Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 352
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
xi
Figure 114
Figure 115
Figure 116
Figure 117
Figure 118
Figure 119
Figure 120
Figure 121
Figure 122
Figure 123
Figure 124
Figure 125
Figure 126
Figure 127
Figure 128
Figure 129
Figure 130
Figure 131
Figure 132
Figure 133
Figure 134
Figure 135
Figure 136
Figure 137
Figure 138
Figure 139
Figure 140
Figure 141
Figure 142
Figure 143
Figure 144
Figure 145
Figure 146
Figure 147
Figure 148
Figure 149
Figure 150
Figure 151
SIO Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SIO Timing with SGPIOs Disabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SGPIO Output Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Link Activity Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Monitor State Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Memory Detection Logic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interrupt Source Logic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interrupt Destination Logic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Port Module Interrupt Logic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Thermal Diode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
REFCLK/REFCLK2 Jitter Transfer Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
XAUI Output Compliance Mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
nRESET Signal Timing Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MIIM Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SI Timing Diagram for Master Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SI Input Data Timing Diagram for Slave Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SI Output Data Timing Diagram for Slave Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SI_DO Disable Test Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DDR SDRAM Input Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DDR SDRAM Output Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test Load Circuit for DDR3 Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
JTAG Interface Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test Circuit for TDO Disable Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Serial I/O Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test Circuit for Recovered Clock Output Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Two-Wire Serial Read Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Two-Wire Serial Write Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pin Diagram for VSC7442-02, Top Left . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pin Diagram for VSC7442-02, Top Right . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pin Diagram for VSC7444-02, Top Left . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pin Diagram for VSC7444-02, Top Right . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pin Diagram for VSC7448-02, Top Left . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pin Diagram for VSC7448-02, Top Right . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pin Diagram for VSC7449-02, Top Left . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pin Diagram for VSC7449-02, Top Right . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.5 V CMOS Single-Ended REFCLK Input Resistor Network . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.3 V CMOS Single-Ended REFCLK Input Resistor Network . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
358
359
360
362
365
366
370
371
371
379
382
386
395
396
397
398
398
399
399
400
401
402
402
403
403
404
404
411
412
432
433
454
455
475
476
497
499
499
xii
Tables
Table 1
Table 2
Table 3
Table 4
Table 5
Table 6
Table 7
Table 8
Table 9
Table 10
Table 11
Table 12
Table 13
Table 14
Table 15
Table 16
Table 17
Table 18
Table 19
Table 20
Table 21
Table 22
Table 23
Table 24
Table 25
Table 26
Table 27
Table 28
Table 29
Table 30
Table 31
Table 32
Table 33
Table 34
Table 35
Table 36
Table 37
Table 38
Table 39
Table 40
Table 41
Table 42
Table 43
Table 44
Table 45
Table 46
Table 47
Table 48
Table 49
Table 50
Table 51
Table 52
Table 53
Table 54
Product Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Feature Support by Switch Family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Internal Frame Header Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
VStaX Header Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Default Port Numbering and Port Mappings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
SERDES Macro to I/O Pin Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Supported Port Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
QSGMII Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
10G Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
VSC7442-02 Port Numbering and Port Mappings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
VSC7444-02 Port Numbering and Port Mappings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
VSC7448-02 Port Numbering and Port Mappings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
VSC7449-02 Port Numbering and Port Mappings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
DEV1G and DEV2G5 MAC Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
DEV1G and DEV2G5 Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
DEV1G and DEV2G5 Interrupt Sources Register Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
DEV1G and DEV2G5 Port Mode Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . . . 38
DEV1G and DEV2G5 PCS Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
DEV1G and DEV2G5 PCS Test Pattern Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . 40
DEV1G and DEV2G5 PCS EEE Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . . . 41
DEV1G and DEV2G5 100BASE-FX Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . 41
DEV10G Operation Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
DEV10G MAC Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
DEV10G Reset Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
DEV10G Interrupt Sources Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
DEV10G BASE-R PCS Interrupt Sources Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
DEV10G Port Mode Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
DEV10G Port Module Advance Checks Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . 44
DEV10G PCS Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
DEV10G PCS Status Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
DEV10G PCS Test Pattern Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
DEV10G BASE-R PCS Test Pattern Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . 48
DEV10G PCS XAUI Extend Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
DEV10G PCS EEE Configuration and Status Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . 50
DEV10G KR FEC Configuration and Status Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . 50
DEV10G Statistics Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Port Configuration Register Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Port Status Register Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Injection VLAN Register Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
PAUSE Frame Detection Configuration Register Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
PFC Configuration Register Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Port Statistics Configuration Register Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Loopback FIFO Configuration Register Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Loopback FIFO Sticky-Bit Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
VCAP_ES0 and VCAP_SUPER Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Entry Bit Encoding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
VCAP CLM Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
VCAP CLM Entry Type-Group Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
VCAP CLM Action Type-Group Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
VCAP CLM Entry/Action Bit Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
VCAP CLM Default Rule Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
VCAP IS2 Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
VCAP IS2 Entry Type-Group Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
VCAP IS2 Entry/Action Bit Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
xiii
Table 55
Table 56
Table 57
Table 58
Table 59
Table 60
Table 61
Table 62
Table 63
Table 64
Table 65
Table 66
Table 67
Table 68
Table 69
Table 70
Table 71
Table 72
Table 73
Table 74
Table 75
Table 76
Table 77
Table 78
Table 79
Table 80
Table 81
Table 82
Table 83
Table 84
Table 85
Table 86
Table 87
Table 88
Table 89
Table 90
Table 91
Table 92
Table 93
Table 94
Table 95
Table 96
Table 97
Table 98
Table 99
Table 100
Table 101
Table 102
Table 103
Table 104
Table 105
Table 106
Table 107
Table 108
Table 109
Table 110
Table 111
Table 112
Table 113
VCAP LPM Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
VCAP LPM Entry Type-Group Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
VCAP LPM Entry/Action Bit Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
VCAP ES0 Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
VCAP ES0 Entry/Action Bit Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
CLM X2 Entry Type-Group and Distribution Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
CLM X4 Entry Type-Group and Distribution Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Pipeline Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Pipeline Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
VCAP CLM Keys and Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
VCAP CLM Key Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
VCAP CLM X1 Key Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
VCAP CLM X2 Key Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
VCAP CLM X4 Key Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
VCAP CLM X8 Key Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
VCAP CLM X16 Key Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
VCAP CLM Action Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
VCAP CLM Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
VLAN Tag Extraction Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Routing Tag Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Frame Acceptance Filtering Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
QoS, DP, and DSCP Classification Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
VLAN Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Aggregation Code Generation Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
CPU Forwarding Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
Frame Type Definitions for CPU Forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Port Configuration of VCAP CLM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Miscellaneous VCAP CLM Key Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
VCAP CLM Range Checker Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . 118
VCAP CLM QoS Mapping Table Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
VLAN Table (5120 Entries) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
MSTP Table (66 Entries) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Common VLAN and MSTP Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
VLAN Table Update Engine (TUPE) Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
VCAP LPM Key and Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
VCAP LPM Key Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
VCAP LPM SGL_IP4 Key Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
VCAP LPM DBL_IP4 Key Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
VCAP LPM SGL_IP6 Key Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
VCAP LPM DBL_IP6 Key Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
VCAP LPM Action Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
VCAP LPM Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
CPU Queue Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Ingress Router Leg Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
Ingress Router Leg Statistics Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
Egress Router Leg Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
Egress Router Leg Statistics Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
VCAP IS2 Keys and Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
VCAP IS2 Key Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
VCAP IS2 Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
VCAP IS2 Frame Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
Port Configuration of VCAP IS2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
VCAP IS2 Key Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
VCAP IS2 Range Checker Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
Other VCAP IS2 Key Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
Combining VCAP IS2 Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
VCAP IS2 Statistics and Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164
ANA_ACL Address Swapping and Rewriting Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
ANA_ACL Routing Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
xiv
Table 114
Table 115
Table 116
Table 117
Table 118
Table 119
Table 120
Table 121
Table 122
Table 123
Table 124
Table 125
Table 126
Table 127
Table 128
Table 129
Table 130
Table 131
Table 132
Table 133
Table 134
Table 135
Table 136
Table 137
Table 138
Table 139
Table 140
Table 141
Table 142
Table 143
Table 144
Table 145
Table 146
Table 147
Table 148
Table 149
Table 150
Table 151
Table 152
Table 153
Table 154
Table 155
Table 156
Table 157
Table 158
Table 159
Table 160
Table 161
Table 162
Table 163
Table 164
Table 165
Table 166
Table 167
Table 168
Table 169
Table 170
Table 171
Table 172
ANA_ACL PTP Processing and Rewriting Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
MAC Table Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
MAC Table Access Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
MAC Table Access Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
Scan Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174
Scan Modification Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
Forwarding Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176
Hardware-Based Learning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
Automated Age Scan Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
Analyzer Interrupt Handling Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
PGID Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
Source Table Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
Aggregation Table Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
GLAG Forward Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
Policer Control Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
Service and Bundle Dual Leaky Bucket Table Entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
BUM Single Leaky Bucket Table Entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
ACL Policer Table Entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
Priority Policer Table Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
Port Policer Table Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
Storm Policer Table Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196
Analyzer Port Statistics Register Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
Queue Statistics Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
BUM Policer Statistics Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
ACL Policer Statistics Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
Analyzer Routing Statistics Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
Analyzer sFlow Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
ANA_AC Mirror Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
Port Definitions in Shared Queue System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
Ingress Port Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
Analyzer Result . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
Buffer Control Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
Buffer Status Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
Statistics Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
Forward Pressure Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
Analyzer Destination Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212
Frame Forwarder Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212
Analyzer Congestion Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
Strict Priority Sharing Configuration Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
Per Priority Sharing Configuration Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
WRED Sharing Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217
Threshold Configuration Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217
Congestion Control Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
Frame Forwarder Monitoring Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
Queue Mapping Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222
Queue Limitation Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224
Queue Limitation Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224
Shaper Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
Scheduler Arbitration Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227
Miscellaneous Scheduler Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228
Frame Aging Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228
Statistics Address Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
Statistics Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230
EEE Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
Calendar Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232
Frame Table Entry Register Overview (4,096 entries) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233
DTI Table Entry Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
Miscellaneous DTI Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
TTI Timer Ticks Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
xv
Table 173
Table 174
Table 175
Table 176
Table 177
Table 178
Table 179
Table 180
Table 181
Table 182
Table 183
Table 184
Table 185
Table 186
Table 187
Table 188
Table 189
Table 190
Table 191
Table 192
Table 193
Table 194
Table 195
Table 196
Table 197
Table 198
Table 199
Table 200
Table 201
Table 202
Table 203
Table 204
Table 205
Table 206
Table 207
Table 208
Table 209
Table 210
Table 211
Table 212
Table 213
Table 214
Table 215
Table 216
Table 217
Table 218
Table 219
Table 220
Table 221
Table 222
Table 223
Table 224
Table 225
Table 226
Table 227
Table 228
Table 229
Table 230
Table 231
TTI Parameters (4096) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
TTI Calendar Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
Miscellaneous TTI Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
AFI TUPE Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
Port Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
ES0 Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
VCAP_ES0 Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248
VCAP_ES0 Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249
Rewriter Pipeline Point Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254
Pipeline Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254
Pipeline Point Updating Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255
Frame Loopback Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
Pipeline Action Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
Loopback IFH Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
Egress Statistics Control Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257
ESDX Index Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257
Egress Statistics Update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258
Mapping Table Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
Port VLAN Tag Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260
ES0 VLAN Tag Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262
Port-Based DSCP Editing Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265
Rewriter VStaX Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266
GCPU Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267
Routing SMAC Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268
L3 Routing Egress Mapping VLAN (EVMID) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268
Mirror Probe Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268
IFH Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270
Replication Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271
Basic Port Setup Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271
Buffer Maintenance Configuration Register Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272
PAUSE Frame Generation Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 272
PAUSE Frame Reception Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273
PFC PAUSE Frame Generation Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . . . 273
Half-Duplex Mode Flow Control Configuration Register Overview . . . . . . . . . . . . . . . . . . . . . . . . 273
Aging Configuration Register Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274
Aging Status Register Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274
Rate Limiting Common Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274
Rate Limiting Frame Overhead Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . . . 275
Rate Limiting Payload Data Rate Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . . 275
Rate Limiting Frame Rate Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276
Error Detection Status Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276
Layer 1 Timing Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276
Layer 1 Timing Recovered Clock Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277
Recovered Clock Settings for 1 Gbps or Lower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277
Recovered Clock Settings for 2.5 Gbps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278
Recovered Clock Settings for XAUI/RXAUI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278
Recovered Clock Settings for SFI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279
Recovered Clock Settings for Secondary PLL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279
Squelch Configuration for Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
Timing Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281
Rewriter PTP Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283
Rewriter Operations for One-Step Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
LoadStore Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 286
IEEE 1588 Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287
PTP Actions in Rewriter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287
Rewriter Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288
Port Module Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288
I/O Delays at 250 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289
I/O Delays at 278 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
xvi
Table 232
Table 233
Table 234
Table 235
Table 236
Table 237
Table 238
Table 239
Table 240
Table 241
Table 242
Table 243
Table 244
Table 245
Table 246
Table 247
Table 248
Table 249
Table 250
Table 251
Table 252
Table 253
Table 254
Table 255
Table 256
Table 257
Table 258
Table 259
Table 260
Table 261
Table 262
Table 263
Table 264
Table 265
Table 266
Table 267
Table 268
Table 269
Table 270
Table 271
Table 272
Table 273
Table 274
Table 275
Table 276
Table 277
Table 278
Table 279
Table 280
Table 281
Table 282
Table 283
Table 284
Table 285
Table 286
Table 287
Table 288
Table 289
Table 290
VRAP Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289
VLAN Table Configuration Before APS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298
VLAN TUPE Command for Ring Protection Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
VLAN Table Configuration After APS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
MAC Table Flush, First Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
Pin Strapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302
Clocking and Reset Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307
Shared Bus Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310
SI Slave Mode Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313
SI Slave Mode Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314
MIIM Slave Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316
MIIM Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316
VCore Shared Bus Access Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318
Mailbox and Semaphore Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 319
Manual PCIe Bring-Up Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321
Base Address Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322
PCIe Outbound Interrupt Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323
Outbound Access Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323
PCIe Access Header Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324
FDMA PCIe Access Header Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324
Power Management Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325
PCIe Wake Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325
FDMA Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326
SI Boot Controller Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334
Serial Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 335
SI Master Controller Configuration Registers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 337
SI Master Controller Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338
DDR3/DDR3L Controller Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341
General DDR3/DDR3L Timing and Mode Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342
Memory Controller Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343
Timer Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 346
UART Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347
UART Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348
Two-Wire Serial Interface Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 349
Two-Wire Serial Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350
MIIM Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351
MIIM Management Controller Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 352
GPIO Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 353
GPIO Overlaid Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 354
Parallel Signal Detect Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 356
SIO Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 357
SIO Controller Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 357
Blink Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 360
SIO Controller Port Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 361
Fan Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363
Fan Controller Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363
Temperature Sensor Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364
Integrity Monitor Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364
Memories with Integrity Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 366
Interrupt Controller Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 367
Interrupt Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 368
Interrupt Destinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 370
External Interrupt Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372
Internal Pull-Up or Pull-Down Resistors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
Reference Clock Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
CLKOUT2 Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
DDR3 SDRAM Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374
DDR3L SDRAM Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374
1G Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
xvii
Table 291
Table 292
Table 293
Table 294
Table 295
Table 296
Table 297
Table 298
Table 299
Table 300
Table 301
Table 302
Table 303
Table 304
Table 305
Table 306
Table 307
Table 308
Table 309
Table 310
Table 311
Table 312
Table 313
Table 314
Table 315
Table 316
Table 317
Table 318
Table 319
Table 320
Table 321
Table 322
Table 323
Table 324
Table 325
Table 326
Table 327
Table 328
Table 329
Table 330
Table 331
Table 332
Table 333
Table 334
Table 335
Table 336
Table 337
Table 338
Table 339
Table 340
Table 341
Table 342
Table 343
Table 344
Table 345
Table 346
Table 347
Table 348
Table 349
1G Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375
6G Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 376
6G Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 376
10G Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377
10G Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377
I/O Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377
GPIO, SI, JTAG, and Miscellaneous Signals DC Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 378
MIIM Interface DC Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 378
Recovered Clock Output DC Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 378
Thermal Diode Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 379
REFCLK Reference Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 380
REFCLK2 Reference Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 380
CLKOUT2 Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 382
100BASE-FX, SGMII, SFP, 1000BASE-KX Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 382
100BASE-FX, SGMII, SFP, 1000BASE-KX Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383
100BASE-FX, SGMII, SFP, 2.5G, 1000BASE-KX Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . 384
100BASE-FX, SGMII, SFP, 2.5G, 1000BASE-KX Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384
XAUI, 10BASE-CX4, 10GBASE-KX4 Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 385
XAUI, 10BASE-CX4, 10GBASE-KX4 Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 386
PCIe Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 387
PCIe Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 387
QSGMII Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 387
QSGMII Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 388
RXAUI Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 389
RXAUI Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 389
100BASE-FX, SGMII, SFP, 1000BASE-KX, 2.5G Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . 390
100BASE-FX, SGMII, SFP, 1000BASE-KX, 2.5G Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 390
10G Transmitter Output (SFI Point B, Host) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 391
10G Transmitter Output (SFI Point B, Host) for Direct Attach Copper . . . . . . . . . . . . . . . . . . . . . 392
10G Receiver Input (SFI Point C and C”, Host) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 392
10G Receiver Input (SFI Point C, Host) for Direct Attach Copper . . . . . . . . . . . . . . . . . . . . . . . . 393
10G Transmitter Output (SFI Point A, ASIC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 393
SFI Input Receiver (SFI Point D, ASIC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394
10GBASE-KR Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394
10GBASE-KR Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 395
nRESET Timing Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 395
MIIM Timing Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 396
SI Boot Timing Specifications for Master Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 396
SI Timing Specifications for Master Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397
SI Timing Specifications for Slave Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 398
DDR3/DDR3L SDRAM Input Signal AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 399
DDR3/DDR3L SDRAM Output Signal AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400
JTAG Interface AC Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 402
Serial I/O Timing Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403
Recovered Clock Output AC Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 404
Two-Wire Serial Interface AC Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405
IEEE1588 Time Tick Output AC Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405
Operating Current for VSC7442-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 406
Operating Current for VSC7444-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 406
Operating Current for VSC7448-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 407
Operating Current for VSC7449-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 407
Power Consumption for VSC7442-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 408
Power Consumption for VSC7444-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 408
Power Consumption for VSC7448-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 408
Power Consumption for VSC7449-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 408
Power Consumption, Reduced Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 408
Recommended Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 409
Stress Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 410
Pin Type Symbol Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 412
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
xviii
Table 350
Table 351
Table 352
Table 353
Table 354
Table 355
Table 356
Table 357
Table 358
Table 359
Table 360
Table 361
Table 362
Table 363
Table 364
Table 365
Table 366
Table 367
Table 368
Table 369
Table 370
Table 371
Table 372
Table 373
Table 374
Table 375
Table 376
Table 377
Table 378
Table 379
Table 380
Table 381
Table 382
Table 383
Table 384
Table 385
Table 386
Table 387
Table 388
Table 389
Table 390
Table 391
Table 392
Table 393
Table 394
Table 395
Table 396
Table 397
Table 398
Table 399
Table 400
Table 401
Table 402
DDR3/DDR3L SDRAM Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GPIO Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
JTAG Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MII Management Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Miscellaneous Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PCI Express Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Supply and Ground Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SERDES1G Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SERDES6G Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SERDES10G Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Serial CPU Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System Clock Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pin Type Symbol Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DDR3/DDR3L SDRAM Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GPIO Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
JTAG Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MII Management Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Miscellaneous Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PCI Express Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Supply and Ground Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SERDES1G Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SERDES6G Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SERDES10G Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Serial CPU Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System Clock Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pin Type Symbol Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DDR3/DDR3L SDRAM Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GPIO Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
JTAG Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MII Management Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Miscellaneous Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PCI Express Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Supply and Ground Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SERDES1G Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SERDES6G Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SERDES10G Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Serial CPU Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System Clock Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pin Type Symbol Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DDR3/DDR3L SDRAM Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GPIO Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
JTAG Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MII Management Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Miscellaneous Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PCI Express Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Supply and Ground Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SERDES1G Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SERDES6G Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SERDES10G Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Serial CPU Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System Clock Interface Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Thermal Resistances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
413
414
414
414
415
415
416
416
416
418
418
418
433
434
435
435
435
436
436
436
437
437
439
440
440
455
456
457
457
457
458
458
458
459
459
461
461
462
476
477
478
478
478
479
479
479
480
480
482
482
483
498
501
xix
Revision History
1
Revision History
The revision history describes the changes that were implemented in the document. The changes are
listed by revision, starting with the most current publication.
1.1
Revision 4.1
Revision 4.1 was published in April 2019. The following is a summary of changes in revision 4.1 of
thisdocument.
•
•
1.2
The Design Considerations chapter was updated with an issue regarding VCAP ES0 actions and
SDLB policers. For more information, see Design Considerations, page 500.
The Pin Strapping table has been updated. For more information, see Table 237, page 302.
Revision 4.0
Revision 4.0 was the first production-level publication of this document.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
1
Product Overview
2
Product Overview
The VSC7442-02 SparX-IV-52™, VSC7444-02 SparX-IV-44™, VSC7448-02 SparX-IV-80™, and
VSC7449-02 SparX-IV-90™ SMB/SME/Industrial Ethernet switch family provides a rich set of Enterprise
and Industrial Ethernet switching features such as advanced TCAM-based VLAN and QoS processing
enabling delivery of differentiated services, security through TCAM-based frame processing using
Versatile Content Aware Processor (VCAP), protection switching, IEEE 1588v2 precision time protocol,
and synchronous Ethernet. IPv4/IPv6 Layer 3 (L3) routing is supported with up to 4K IPv4 (1K IPv6)
unicast LPM entries and up to 2K IPv4 (512 IPv6) L3 multicast groups. L3 security features include
source guard and reverse path forwarding (uRPF) tasks.
A powerful 500 MHz MIPS-24KEc CPU enables full management of the switch and advanced Enterprise
and Industrial applications.
The devices target managed Layer 2 and Layer 3 equipment in SMB, SME, and industrial applications
where high port count 1G switching with 10G aggregation links is required.
The VSC7442-02 SparX-IV-52™ device is a 52 Gbps SMB/SME/Industrial Ethernet switch with up to 52
ports supporting the following main port configuration:
•
12 × QSGMII ports + 4 × 1G SGMII ports
The VSC7444-02 SparX-IV-44™ device is a 44 Gbps (60 Gbps with 2.5G SGMII ports)
SMB/SME/Industrial Ethernet switch with up to 26 ports supporting the following main port
configurations:
•
•
•
•
26 × 1G SGMII ports
24 × 1G SGMII ports + 2 × 10G SFI/XAUI/RXAUI ports
6 × QSGMII ports + 2 × 10G SFI/XAUI/RXAUI ports
16 × 2.5G SGMII ports + 2 × 10G SFI/XAUI/RXAUI ports
The VSC7448-02 SparX-IV-80™ device is an 80 Gbps SMB/SME/Industrial Ethernet switch with up to 52
ports supporting the following main port configurations:
•
•
•
•
•
•
•
•
20 × 1G SGMII ports + 4 × 10G ports (1 × 10G SFI + 3 × 10G SFI/XAUI/RXAUI ports)
24 × 1G SGMII ports + 4 × 10G ports (2 × SFI + 2 × SFI/XAUI/RXAUI)
32 × 1G SGMII ports + 4 × 10G SFI ports
36 × 1G SGMII ports
10 × QSGMII ports + 4 × 10G ports (2 × SFI + 2 × SFI/XAUI/RXAUI)
12 × QSGMII ports + 3 × 10G ports (1 × SFI + 2 × SFI/XAUI/RXAUI)
16 × 2.5G SGMII ports + 4 × 10G ports (2 × SFI + 2 × SFI/XAUI/RXAUI)
24 × 2.5G SGMII ports + 2 × 10G SFI ports
The VSC7449-02 SparX-IV-90™ device is a 90 Gbps SMB/SME/Industrial Ethernet switch with up to 52
ports supporting the following main port configurations, in addition to port configurations supported by
VSC7448-02 and VSC7449-02.
•
•
•
12 × QSGMII ports + 4 × 10G ports (2 × SFI + 2 × SFI/XAUI/RXAUI)
20 × 2.5G SGMII ports + 4 × 10G ports (2 × SFI + 2 × SFI/XAUI/RXAUI)
20 × 2.5G SGMII ports + 4 × 10G SFI ports or 24 × 2.5G SGMII ports + 3 × 10G SFI ports
In addition, all devices support one 10/100/1000 Mbps SGMII/SerDes Node Processor Interface (NPI)
Ethernet port.
2.1
General Features
This section lists the key device features and benefits.
2.2
Layer 2 and Layer 3 Forwarding
•
•
•
IEEE802.1Q switch with 4K VLANs and 32K MAC table entries
Push/pop/translate up to three VLAN tags on ingress and egress
RSTP and MSTP support
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
2
Product Overview
•
•
•
•
2.3
Timing and Synchronization
•
•
•
2.4
•
•
•
•
•
•
•
Four megabytes of integrated shared packet memory (two megabytes in VSC7442-02 and
VSC7444-02)
Eight QoS classes with a pool of up to 32K queues
TCAM-based classification with pattern matching against Layer 2 through Layer 4 information
Dual-rate policers selected by VCAP IS2, eight single-rate priority policers per port, and four singlerate port policers for each port
Flexible 4K ingress QoS mappings and 8K egress QoS mappings for VLAN tags and DSCP values
Up to 4K egress VLAN tag operations
Audio/video bridging (AVB) with support for time-synchronized, low-latency audio and video
streaming services
Priority-based flow control (PFC) (IEEE 802.1Qbb)
Security
•
•
•
•
2.6
Synchronous Ethernet, with four clock outputs recovered from any port
IEEE 1588-2008 (v2) with nanosecond-accurate time stamping for one-step and two-step clocks
Hardware processing and PTP frame generation
Quality of Service
•
2.5
Fully nonblocking wire-speed switching performance for all frame sizes
IPv4/IPv6 unicast and multicast Layer 2 switching with up to 32K groups and 1K port masks
IPv4/IPv6 unicast and multicast Layer 3 forwarding (routing) with reverse path forwarding (RPF)
support
IGMPv2, IGMPv3, MLDv1, and MLDv2 support
Versatile Content Aware Processor (VCAP™) packet filtering engine using ACLs for ingress and
egress packet inspection
Storm controllers for flooded broadcast, flooded multicast, and flooded unicast traffic
Per-port, per-address registration for copying/redirecting/discarding
32 VCAP single-rate policers
Management
•
•
•
•
•
•
•
•
•
•
VCore-III™ CPU system with integrated 500 MHz MIPS 24KEc CPU with MMU and DDR3/DDR3L
SDRAM controller
PCIe 1.x CPU interface
CPU frame extraction (eight queues) and injection (two queues) through DMA, which enables
efficient data transfer between Ethernet ports and CPU/PCIe
EJTAG debug interface
Configurable 16-bit or 8-bit DDR3 SDRAM interface supporting up to one gigabyte (GB) of memory
Sixty-four pin-shared general-purpose I/Os:
Serial GPIO and LED controller controlling up to 32 ports with four LEDs each
Triple PHY management controller (MIIM)
Dual UART
Dual built-in two wire serial interface multiplexer
External interrupts
1588 synchronization I/Os
SFP loss of signal inputs
External access to registers through PCIe, SPI, MIIM, or through an Ethernet port with inline
Versatile Register Access Protocol (VRAP)
Per-port counter set with support for the RMON statistics group (RFC 2819) and SNMP interfaces
group (RFC 2863)
Energy Efficient Ethernet (EEE) (IEEE 802.3az)
Support for CPU modes with internal CPU only, external CPU only, or dual CPU
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
3
Product Overview
2.7
Product Parameters
All SerDes, packet memory, and configuration tables necessary to support network applications are
integrated. The following table lists the primary parameters for the devices.
Product Parameters
Table 1 •
Features and Port Configurations
VSC7442-02
VSC7444-02
VSC7448-02
VSC7449-02
Maximum bandwidth excluding 1G NPI port
52 Gbps
1G: 44 Gbps
2.5G: 60 Gbps
80 Gbps
90 Gbps
Maximum number of ports excluding 1G NPI
port
52
26
52
52
Maximum number of QSGMII ports
12
6
12
12
Maximum number of 1G ports excluding 1G NPI 52
port
26
52
52
Maximum number of 1G SGMII ports excluding 16
1G NPI port
26
36
36
Maximum number of 2.5G ports
0
16
24
24
Maximum number of 10G ports
(SFI/XAUI/RXAUI)
0
2
4
4
SERDES1G lanes including 1G NPI port
1
9
9
9
SERDES6G lanes
12
24
24
24
4
2
4
4
Packet buffer
16 Mb
16 Mb
32 Mb
32 Mb
MAC table size
32K
32K
32K
32K
Layer 2 multicast port masks
1K
1K
1K
1K
Super VCAP blocks (4K x 36 bits per block)
4
6
8
8
VCAP CLM entries (36 bits) per super VCAP
block
4K
4K
4K
4K
VCAP LPM entries
IPv4: 4K
IPv6: 1K
IPv4: 4K
IPv6: 1K
IPv4: 4K
IPv6: 1K
IPv4: 4K
IPv6: 1K
VCAP IS2 entries (288 bits) per super VCAP
block
512
512
512
512
VCAP ES0 entries
4K
4K
4K
4K
Router legs
128
128
128
128
IP unicast routes/hosts
IPv4: 4K
IPv6: 1K
IPv4: 4K
IPv6: 1K
IPv4: 4K
IPv6: 1K
IPv4: 4K
IPv6: 1K
Next-hop/ARP table entries
2K
2K
2K
2K
IP (S,G) or (*, G) multicast groups (shared with IPv4: 2K
IP unicast routes)
IPv6: 512
IPv4: 2K
IPv6: 512
IPv4: 2K
IPv6: 512
IPv4: 2K
IPv6: 512
Multicast router leg masks
1K
1K
1K
1K
ECMPs
16
16
16
16
4K
4K
4K
4K
SERDES10G
lanes(1)
Layer 2 Switching
Layer 3 Routing
Quality of Service and Security
Ingress QoS mapping table entries
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
4
Product Overview
Table 1 •
Product Parameters (continued)
Features and Port Configurations
VSC7442-02
VSC7444-02
VSC7448-02
VSC7449-02
Egress QoS mapping table entries
8K
8K
8K
8K
512
512
512
Security enforcement (ACL) rules (288 bits) per 512
super VCAP block allocated to VCAP IS2
1.
For VSC7442-02, SERDES10G lane supports up to 1 Gbps.
2.8
Applications
The devices target the following applications.
•
•
2.9
Industrial Ethernet equipment with protection switching and IEEE 1588 timing requirements
Fully managed Layer 2 and Layer 3 SMB and SME equipment, such as high port count 1G switches
with 10G aggregation links
Functional Overview
This section provides an overview of all the major blocks and functions involved in the forwarding
operation in the same order as a frame traverses through the device. It also outlines other major
functionality of the devices, such as the CPU subsystem and IEEE 1588 PTP processing.
The following illustration shows the VSC7448-02 block diagram. The block diagrams for VSC7442-02,
VSC7444-02, and VSC7449-02 are similar, but with different port module and SerDes lane
configurations.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
5
Product Overview
Figure 1 •
VSC7448-02 Block Diagram
Shared Queue System
Discard Statistics
EJTAG
Memory Controller
MIPS 24KEc
MMU
Automated Frame
Injection (AFI)
Shared Memory Pool
I-Cache
32 kB
Hierarchical QoS
Shaper and Scheduler
D-Cache
32 kB
Interrupt
Controller
Temperature
Sensor
Switch Core
Access
Block
Timers
VCore Arbiter
Analyzer
Ingress Processing
Rewriter
Egress Processing
Protection Switching
Egress VCAP Lookup
VCore CPU Bus
Manual Frame
Inject/Extract
VCore SBA
Access
Block
Switch Core
Registers
Frame DMA
(FDMA)
SI Slave
MIIM Slave
Forwarding L2/L3
Frame Editing:
VLAN tags
DSCP
IEEE1588
L2/L3/L4
Arrival Stats
Policing
(Port, QoS, ACL)
VRAP
Ethernet Register
Access
Access Control Lists
Departure Stats
Ingress Classification
(VLAN and QoS Mapping)
4
SyncE
2
MIIM
IEEE1588 Engine
4
PCIe
Port L2CP Handling
JTAG
IEEE1588 Engine
SI
6
4
DDR3/DDR3L Memory Controller
GPIO
56
64
LED, serial GPIO, UART, LOS,
Two-wire serial interface, IRQ, 1588, MIIM
Frame bus
x29
x24
2
x4
1G Port Modules
2.5G Port Modules
10G Port Modules
MAC, PCS
1588/OAM Timestamping
MAC, PCS
1588/OAM Timestamping
MAC, PCS XAUI/RXAUI/SFI, KR FEC
1588/OAM Timestamping
x4
2
3
10GBASE -KR Training
3
I/O Muxing
2
SerDes1G
Lane
(NPI)
SerDes1G
Lane
SerDes6G
Lane
SerDes6G
Lane
SerDes10G
Lane
SerDes10G
Lane
S0_TXN
S0_TXP
S0_RXN
S0_RXP
S8_TXN
S8_TXP
S8_RXN
S8_RXP
S9_TXN
S9_TXP
S9_RXN
S9_RXP
S32_TXN
S32_TXP
S32_RXN
S32_RXP
S33_TXN
S33_TXP
S33_RXN
S33_RXP
S36_TXN
S36_TXP
S36_RXN
S36_RXP
1G SGMII
100BASE-FX
2.9.1
1G SGMII
2.5G SGMII
QSGMII
XAUI/RXAUI
100BASE-FX
RCVRD_CLK
MIIM
PCIE
JTAG
SI
DDR
GPIO
nRESET
REFCLK
REFCLK2
REFCLK_EN
REFCLK_SEL
REFCLK2_EN
REFCLK2_SEL
THERMDC
THERMDA
SERDES_Rext
1G SGMII
2.5G SGMII
SFI
100BASE-FX
Frame Arrival in Ports and Port Modules
The Ethernet interfaces receive incoming frames and forward these to the port modules.
Each port module contains a Media Access Controller (MAC) that performs a full suite of checks, such as
VLAN tag-aware frame size checking, frame check sequence (FCS) checking, and pause frame
identification.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
6
Product Overview
Each port module connects to a SerDes macro and contains a Physical Coding Sublayer (PCS), which
performs 8b/10b or 64b/66b encoding, auto-negotiation of link speed and duplex mode, and monitoring
of the link status.
Symmetric and asymmetric pause flow control are both supported as well as priority-based flow control
(IEEE 802.1Qbb).
All Ethernet ports support Energy Efficient Ethernet (EEE) according to IEEE 802.3az. The shared queue
system is capable of controlling the PCS operating states, which are active or low power. The PCS
understands the line signaling as required for EEE. This includes signaling of active, sleep, quiet, refresh,
and wake.
2.9.1.1
1G SGMII Line Ports
1G SGMII line ports operate in one of the following modes:
•
•
•
2.9.1.2
10/100/1000 Mbps SGMII. The SGMII interface connects to an external copper PHY device or
copper SFP optical module with SGMII interface. In this mode, autonegotiation is supported for link
speed, duplex settings, pause settings, and remote fault signaling. Full-duplex is supported for all
speeds, while half-duplex is supported for 10/100 Mbps.
100BASE-FX. The 100BASE-FX interface connects directly to a 100BASE-FX SFP optical module.
Autonegotiation is not specified for 100BASE-FX and is not supported. Operation is always
100 Mbps and full duplex.
1000BASE-X. The 1000BASE-X interface connects directly to a 1000BASE-X SFP optical module.
Autonegotiation is supported for pause settings and remote fault signaling. Operation is always
1000 Mbps and full duplex. 1G backplane Ethernet 1000BASE-KX is fully supported, including
autonegotiation.
2.5G SGMII Line Ports
The 2.5G interface connects directly to an SFP optical module. Operation is always 2500 Mbps and full
duplex. 2.5G backplane Ethernet is also supported.
2.9.1.3
1G QSGMII Line Ports
1G QSGMII line ports operate in quad 10/100/1000 Mbps QSGMII. The QSGMII interface connects to an
external copper PHY device. In this mode, autonegotiation is supported for link speed, duplex settings,
pause settings, and remote fault signaling. Full-duplex is supported for all speeds, while half-duplex is
supported for 10/100 Mbps.
2.9.1.4
10G Line Ports
10G line ports can operate in one of the following modes. All ports support SFI but some ports may not
support XAUI and RXAUI.
•
•
2.9.2
10 Gbps SFI. The interface connects directly to a 10GBASE-R SFP+ optical module or an external
PHY device. Auto-negotiation is supported for pause settings, remote fault signaling, and backplane
Ethernet functions. The 10G or 1G operation is supported for SFP+ optical modules, and operation
is always full duplex.
•
10G backplane Ethernet 10GBASE-KR (serial backplane) is fully supported, including
autonegotiation, training, and 10GBASE-KR FEC.
•
When used with external devices capable of WAN-PHY (10GBASE-W) operation, the 10G line
ports support pacing operation as specified for 10GBASE-W operation.
10 Gbps XAUI/RXAUI. This interface supports four-lane XAUI or two-lane RXAUI and connects to
external devices supporting these interfaces. Autonegotiation is supported for pause settings,
remote fault signaling, and backplane Ethernet functions. 10G or 1G operation is supported for
SFP+ optical modules, and operation is always full duplex.
•
10G backplane Ethernet 10GBASE-KX4 (four-lane backplane) and 10GBASE-CX4 (four-lane
copper) are fully supported, including autonegotiation.
Basic Classification
Basic frame classification in the ingress processing module (the analyzer) receives all frames before
further classification processing is performed. The basic classifier uses configurable logic to classify each
frame to a VLAN, QoS class, drop precedence (DP) level, DSCP value, and an aggregation code. This
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
7
Product Overview
information is carried through the switch together with the frame and affects policing, drop precedence
marking, statistics collecting, security enforcement, Layer 2 and Layer 3 forwarding, and rewriting.
The basic classifier also performs a general frame acceptance check. The output from the basic
classification may be overwritten or changed by the more intelligent advanced classification using the
TCAM-based VCAP.
2.9.3
Security and Control Protocol Classification
Before being passed on to the Layer 2 forwarding, all frames are inspected by the VCAP IS2 for security
enforcement and control protocol actions.
The action associated with each IS2 entry (programmed into the IS2 action RAM) includes frame filtering,
single leaky bucket rate limiting (frame or byte based), snooping to CPU, redirecting to CPU, mirroring,
time stamping, and accounting. Although the VCAP IS2 is located in the ingress path of the device, it has
both ingress and egress capabilities.
The VCAP IS2 engine embeds powerful protocol awareness for well-known protocols such as LLC,
SNAP, ARP, IPv4, IPv6, and UDP/TCP. IPv6 is supported with full matching against both the source and
the destination IP addresses.
For each frame, up to two lookup keys are generated and matched against the VCAP entries.
2.9.4
Policing
Each frame is subject to one or more of the following policing operations.
•
•
•
•
•
•
•
Single-rate priority policers. Ingress port number and QoS class determine which policer to use.
Single-rate port policers. Ingress port number determines which policer to use.
VCAP single-rate policers. IS2 action selects which VCAP single-rate policer to use.
VCAP dual-rate policers. IS2 action selects which VCAP dual-rate policer to use.
Single-rate global storm policers. Frame characteristics, such as broadcast, unicast, multicast
(BUM), or learn-frame, select which policer to use.
Single-rate service broadcast, unicast, and multicast (BUM) policers for flooded frames. Service
classification and destination MAC address select which policer to use.
Each frame can trigger up to fourteen policers:
•
•
•
•
•
•
One BUM policer
One priority policer or one dual-rate VCAP policer
One port policer
One VCAP policer
Four port policers
Eight storm policers
Dual-rate policers are MEF-compliant, supporting both color-blind and color-aware operation. The initial
frame color is derived from the drop precedence level from the frame classification. The MEF coupling
mode is also configurable for each policer.
Dual-rate policers ensure Service Level Agreement (SLA) compliance. The outcome of this policing
operation is to mark each accepted frame as in-profile (green) or out-of-profile (yellow). Yellow frames
are treated as excess or discard-eligible and green frames are committed. Frames that exceed the
yellow/excess limits are discarded (red).
The four port policers and eight storm policers can be programmed to limit different types of traffic such
as CPU-forwarded frames, learn frames, known or unknown unicast, multicast, or broadcast.
2.9.5
Layer 2 Forwarding
After the policers, the Layer 2 forwarding block of the analyzer handles all fundamental Layer 2
forwarding operations and maintains the associated MAC table, the VLAN table, and the aggregation
table. The devices implement a 32K MAC table and a 4K VLAN table.
The main task of the analyzer is to determine the destination port set of each frame. The Layer 2
forwarding decision is based on various information such as the frame’s ingress port, source MAC
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
8
Product Overview
address, destination MAC address, and the VLAN identifier, as well as the frame’s VCAP actions,
mirroring, and the destination port’s link aggregation configuration.
Layer 2 forwarding of unicast and Layer 2 multicast frames is based on the destination MAC address and
the VLAN.
The switch can also L2-forward IPv4 and IPv6 multicast frames using additional Layer-3 information,
such as the source IP address. The latter enables source-specific IPv4 multicast forwarding (IGMPv3)
and source-specific IPv6 multicast forwarding (MLDv2). This process of L2-forwarding multicast frames
using Layer 3 information is called “snooping”, which is different from L3-forwarding (routing) of multicast
frames.
The following describes some of the contributions to the Layer 2 forwarding.
•
•
•
•
•
•
•
2.9.6
VLAN Classification VLAN-based forward filtering includes source port filtering, destination port
filtering, VLAN mirroring, and asymmetric VLANs.
Security Enforcement The security decision made by the VCAP IS2 can, for example, redirect the
frame to the CPU based on security filters.
MAC Addresses Destination and source MAC address lookups in the MAC table determine if a
frame is a learn frame, a flood frame, a multicast frame, or a unicast frame.
Learning By default, the device performs hardware learning on all ports. However, certain ports
could be configured with secure learning enabled, where an incoming frame with unknown source
MAC address is classified as a “learn frame” and is redirected to the CPU. The CPU performs the
learning decision and also decides whether the frame is forwarded.
Learning can also be disabled. If learning is disabled, it does not matter if the source MAC address
is in the MAC table.
Link Aggregation A frame targeted to a link aggregate is processed to determine which physical
port of the link aggregate group the frame must be forwarded to.
Mirroring Mirror probes may be set up in different places in the forwarding path for monitoring
purposes. As part mirroring, a copy of the frame is sent either to the CPU or to another port.
Layer 3 Forwarding
The VSC7444-02, VSC7448-02, and VSC7449-02 devices support Layer 3 forwarding (routing), which is
performed by the analyzer. With Layer 3 forwarding, the IPv4 or IPv6 addresses determine the
destination port set and Layer 3 processing is performed on IP header. The Layer 3 forwarding process
also replaces the arrival Layer 2 Ethernet header (including MAC addresses and VLAN tags) with a new
Layer 2 Ethernet header after departure from the switch.
The analyzer supports 128 router legs, and supports Virtual Router Redundancy Protocol (VRRP).
Ingress router legs are addressed using classified arrival VLAN and DMAC address.
If an arrival frame is determined to belong to an ingress router leg and routing is enabled, Layer 3
forwarding is applied. Note that this is in addition to any Layer 2 forwarding, so for example, an arrival
multicast frame may be Layer 2 forwarded on the classified arrival VLAN and also Layer 3 forwarded to
one or more additional VLANs. IP unicast frames only use Layer 2 forwarding or Layer 3 forwarding, but
never both. Layer 3 forwarding always uses the classified arrival VLAN.
Layer 3 forwarding first checks the IP header for validity. IP header checks include IP version, header
length, and header checksum. The Time-to-Live (TTL) or Hop Limit values are also checked for validity
and decremented if the packet is forwarded.
The analyzer then searches the Longest Prefix Match (LPM) table for an exact match of the destination
IP address. If there is not an exact match, the table is searched for the best partial match. If there is no
partial match in the LPM table, the frame is Layer 3 forwarded to the location of the default gateway.
With Layer 3 forwarding, each egress frame copy uses an egress router leg to determine the per-copy
egress encapsulation. There can be up to 16 egress router legs associated with one forwarding entry in
support of Equal Cost Multipath (ECMP) functionality, where multiple forwarding paths are used between
adjacent routers for increased forwarding bandwidth.
Reverse path forwarding (RPF) is optionally performed on multicast and unicast (uRPF) packets as a
security check. This source IP address check helps detect and prevent address spoofing.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
9
Product Overview
Multicast frames can be Layer 2 forwarded on the arrival VLAN as well as Layer 3 forwarded to different
VLANs. Layer 3 forwarding of IP multicast is different from Layer 2 forwarding of IP multicast using
IGMP/MLD snooping in the following ways:
•
•
•
•
IP header checks and TTL processing are performed
The Ethernet header is swapped
The egress VLANs may be different from the ingress VLANs
Multiple frame copies can be generated per physical port
Network control such as ICMP and ARP are redirected to the CPU, along with malformed packets,
packets with expired TTL, and packets with options.
2.9.7
Shared Queue System and Hierarchical Scheduler
The analyzer provides the destination port set of a frame to the shared queue system. It is the queue
system’s task to control the frame forwarding to all destination ports.
The shared queue system embeds memory that can be shared between all queues and ports. Frames
are mapped to queues through a programmable mapping function allowing ingress ports, egress ports,
QoS classes to be taken into account. The sharing of resources between queues and ports is controlled
by an extensive set of thresholds.
Each egress port implements default schedulers and shapers as shown in the following illustration. Per
egress port, the scheduler sees the outcome of aggregating the egress queues (one per ingress port per
QoS class) into eight QoS classes.
2.9.7.1
Class-Based Queuing (Default Configuration)
By default, aggregation is done in a Deficit Weighted Round Robin fashion (DWRR) with equal weights to
all ingress ports within a QoS class, so byte-accurate weighted round robin scheduling between ingress
ports is performed for each QoS class.
The following illustration shows the default scheduler-shaper configuration. Hierarchical schedulingshaping is also possible.
Figure 2 •
Default Scheduler-Shaper Configuration
iCPU
Input Port N
•
•
•
D
W
R
R
S
Input Port 0
7
6
5
4
3
2
1
0
Virtual Input Queues
QoS Class 7
•
•
•
H
M
D
W
R
R
L
S
T
R
I
C
T
Port
Shaper
S
iCPU
Input Port N
•
•
•
Input Port 0
D
W
R
R
S
QoS Class 0
Shaper
Virtual Input Queues
QoS Class 0
Scheduling between QoS classes within the port can use one of the three following methods:
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
10
Product Overview
•
•
•
2.9.8
Strict Priority scheduling. Frames with the highest QoS class are always transmitted before frames
with lower QoS class.
Deficit Weighted Round Robin (DWRR) scheduling. Each QoS class serviced using DWRR sets a
DWRR weight ranging from 0 to 31.
Combination of Strict Priority and DWRR scheduling. The default configuration is shown, where QoS
classes 7 and 6 use strict priority while QoS classes 5 through 0 use DWRR. But any split between
strict and DWRR QoS classes can be configured.
Rewriter and Frame Departure
Before transmitting the frame on the egress line, the rewriter can modify selected fields in the frame such
as Ethernet headers and VLAN tags, IPv4/IPv6 fields, PTP fields, and FCS. The rewriter also updates
the frame’s COS and color indications such as DEI, PCP, and DSCP. Departure statistics are also kept
based on the classified VLAN.
2.9.8.1
Basic VLAN Tagging Operations (Port-based)
By default, the egress VLAN actions are determined by the egress port settings and classified VLAN.
These include basic VLAN operations such as pushing a VLAN tag, untagging for specific VLANs, and
simple translations of DEI, PCP, and DSCP.
2.9.8.2
Advanced VLAN Tagging Operations (Port-based and VCAP-based)
By using the egress VCAP ES0, significantly more advanced VLAN tagging operations can be achieved.
ES0 enables pushing up to three VLAN tags and flexible VLAN tag translation for VLAN tag/TPID, PCP,
DEI, and DSCP control. The lookup by VCAP ES0 includes classified VLAN, egress port, and COS/color
indications.
2.9.8.3
Layer 3 Forwarding (Routing) Operations
Supports per-router-leg control of Ethernet link layer encapsulation and VID, as well as modification of
other Layer 3 fields such as IPv4 TTL, IPv4 checksum, and IPv6 hop limit.
2.9.8.4
PTP (IEEE 1588) Operations
PTP PDU modifications include insertion/update of time stamps and correction fields, as well as updating
the UDP checksum.
The rewriter pads frames to minimum legal size if needed, and updates the FCS if the frame was
modified before the frame is transmitted.
The egress port module controls the flow control exchange of pause frames with a neighboring device
when the interconnection link operates in full-duplex flow control mode.
2.9.9
CPU Port Module
The CPU port module (DEVCPU) contains eight CPU extraction queues and two CPU injection queues.
These queues provide an interface for exchanging frames between the internal CPU system and the
switch core. An external CPU using the serial interface can also inject and extract frames to and from the
switch core by using the CPU port module.
In addition, any Ethernet interface on the device can be used for extracting and injecting frames. The
Ethernet interface used in this way is called the Node Processor Interface (NPI) and is typically
connected to an external CPU.
Injected frames may be prepended with an injection header to control processing and forwarding of these
frames. Extracted frames may be prepended with an extraction header to supply frame arrival and
classification information associated with each frame. These headers may be used by internal CPU or
external CPU.
The switch core can intercept a variety of different frame types and copy or redirect these to the CPU
extraction queues. The classifier can identify a set of well-known frames, such as IEEE reserved
destination MAC addresses (BPDUs, GARPs, CCM/Link trace), as well as IP-specific frames (IGMP,
MLD). Security VCAP IS2 provides another flexible way of intercepting all kinds of frames, such as
specific OAM frames, ARP frames or explicit applications based on TCP/UDP port numbers. In addition,
frames can be intercepted based on the MAC table, the VLAN table, or the learning process.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
11
Product Overview
Whenever a frame is copied or redirected to the CPU, a CPU extraction queue number is associated with
the frame and used by the CPU port module when enqueuing the frame into the eight CPU extraction
queues. The CPU extraction queue number is programmable for every interception option in the switch
core.
2.9.10
Synchronous Ethernet and Precision Time Protocol (PTP)
The switch supports Synchronous Ethernet and IEEE 1588 Precision Time Protocol (PTP) for
synchronizing network timing throughout a network.
Synchronous Ethernet allows for the transfer of precise network timing (frequency) using physical
Ethernet link timing. Each switch port can recover its ingress clock and output the recovered clock to one
of up to four recovered clock output pins. External circuitry can then generate a stable reference clock
input used for egress and core logic timing.
The Precision Time Protocol (PTP) allows for the transfer of precise network timing (frequency) and time
of day (phase) using Ethernet packets. PTP can operate as a one-step clock or a two-step clock. For
one-step clocks, a precise time is calculated and stamped directly into the PTP frames at departure. For
two-step clocks, a precise time is simply recorded and provided to the CPU for further processing. The
CPU can then initiate a follow-up message with the recorded timing.
The devices support PTP Delay_req/Delay_resp processing in hardware where the Delay_req frame is
terminated and a Delay_resp frame is generated based on the request. In addition to updating relevant
PTP time stamps and message fields, the frame encapsulation can be changed. This includes swapping
and rewriting MAC addresses, IP addresses, and TCP/UDP ports, and updating the IPv4 TTL or IPv6
hop limit.
The devices also support generation of PTP Sync frames using the automatic frame injector (AFI)
functionality.
PTP is supported for a range of encapsulations including:
•
•
•
•
PTP over Ethernet
PTP over UDP over IPv4/IPv6 over Ethernet
Either of the above encapsulations over MPLS pseudowire over Ethernet
PTP over UDP over IPv4/IPv6 over MPLS over Ethernet
The switches support two separate timing domains; one for Synchronous Ethernet and data path
forwarding, and one for PTP timing synchronization. This gives the system designer control over how
these two timing architectures interact.
2.9.10.1
CPU Subsystem
The devices contain a powerful, 500 MHz MIPS24KEc-compatible microprocessor, a high bandwidth
Ethernet Frame DMA engine, and a DDR3/DDR3L controller supporting up to 1 gigabyte (GB) of
memory. This complete system-on-chip supports Linux or embedded operating systems, enabling full
management of the switch and advanced software applications.
The device supports external CPU register access by the on-chip PCIe 1.x endpoint controller, by
specially formatted Ethernet frames on the NPI port (Versatile Register Access Protocol), or by register
access interface using SPI protocol. External CPUs can inject or extract Ethernet frames by the NPI port,
by PCIe DMA access, or by register read/writes (using any register-access interface).
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
12
Functional Descriptions
3
Functional Descriptions
This section describes the functional aspects of the VSC7442-02, VSC7444-02, VSC7448-02, and
VSC7449-02 devices, including available configurations, operational features, and testing functionality. It
also defines the device setup parameters that configure the devices for a particular application.
The functional descriptions in this section are shared across the following switch families:
•
•
•
Carrier Ethernet switches: VSC7438-02, VSC7464-02, and VSC7468-02
SMB/SME/Industrial switches: VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02
Stackable SMB/SME switches: VSC7454-02, VSC7458-02, and VSC7459-02
Some functional descriptions do not apply to all three switch families. The following table lists the
features and associated functional aspects not supported by all three switch families. Features not listed
in the table are common to all three switch families.
As an example, the Carrier Ethernet switch family supports MEF services. The support in the Carrier
Ethernet devices is built around an ISDX—an internal parameter used to identify a service instance when
service processing a frame. As a result, the ISDX is part of many functional blocks, such as the VCAP
CLM keys and actions, the analyzer, the rewriter, and the queue system. For switch families other than
the Carrier Ethernet switch family, MEF services are not supported, and the concept of the ISDX cannot
be used. Any reference to ISDX and use of the ISDX is not applicable.
Feature Support by Switch Family
Table 2 •
Carrier
Ethernet
VSC7438-02
VSC7464-02
VSC7468-02
Features
MEF services:
ISDX, VSI, ESDX
Service statistics (ingress, egress)
ISDX selected SDLB policing
x
Versatile OAM processor (VOP):
Hardware OAM processing
Port VOEs, service VOEs, path VOEs
MIPs and MEPs
Y.1564 SAM, SAM sequence
OAM COSID and color
x
MPLS-TP processing (LSR, LER):
VCAP CLM keys: SGL_MLBS, DBL_MLBS, TRI_MLBS
MPLS TC mapping
x
Hierarchical QoS and dual-rate shaping
x
IEEE-1588 and PTP timestamping
x
Stacking:
Learn all frames
Stacking links
Note that the VStaX header is used by all switch families as
an internal frame header and when communicating with
external CPUs.
SMB/SME/Industrial
VSC7442-02
VSC7444-02
VSC7448-02
VSC7449-02
Stackable
SMB/SME
VSC7454-02
VSC7458-02
VSC7459-02
x
x
The following illustration shows an RTL block diagram of the physical blocks in the devices and how the
blocks interconnect. The functional aspects of each block is provided in following sections. The grayed-
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
13
Functional Descriptions
out blocks represent the VCore-III and DEVCPU blocks. For more information about the VCore-III and
DEVCPU blocks, see VCore-III System and CPU Interfaces, page 305.
Figure 3 •
Physical Block Diagram
x9
x24
SERDES1G
DSM
DEV1G
DEV1G
DEV1G
REW
SQS
HSCH
HSIO
VCAP_ES0
x24
SERDES6G
DEV1G
AFI
x29
I/O
Muxing
HSIO
OQS
REW
DEV2G5
DEV2G5
Flow
control
IQS
Priority-based flow control
QSYS
Frame bus
x4
SERDES10G
QRES
QFWD
x4
DEV10G
DEV10G
DEV1G
XGANA/DIG/XFI
ASM
ANA
VD0
VD1
VCore-III
CPU I/F
MIPS
24KEc
DEVCPU
FDMA
Manual
Loopback
ANA_CL
ANA_L3
ANA_ACL
CLM
LPM
IS2
ANA_L2
ANA_AC
Normal
LBK
VCAP_SUPER
LRN
Register target
3.1
Register Notations
This datasheet uses the following general register notations.
::.
is not always present. In that case the following notation is used:
::.
When a register group does exist, it is always prepended with a target in the notation.
In sections where only one register is discussed or the target (and register group) is known from the
context, the :: may be omitted for brevity leading to the following
notation:
.
When a register contains only one field, the . is not included in the notation.
When referring to a specific instance of a register group, specific register instance, or a specific bit in a
field, square brackets are used, for example:
:[]:.
::[].
::.[]
3.2
Frame Headers
This section describes the internal header formats used within the devices that are visible in frames to
and from the CPU, NPI port, and in frames exchanged between devices in multichip configurations.
The header formats are internal frame header (IFH) and VStaX header.
Internal frame header (IFH) IFH is used when extracting frames to CPU and injecting frames from
CPU. The IFH can also be inserted into frames transmitted on the NPI port. The IFH includes a VStaX
header.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
14
Functional Descriptions
VStaX header The VStaX header can be used for transmission to and from an NPI port.
3.2.1
Internal Frame Header Placement
The following illustration shows internal frame header placement.
Figure 4 •
Frame with Internal Frame Header
Bit 223
No Prefix:
Bit 0
Internal Frame Header
DMAC
SMAC
Frame data
Bit 223
Short Prefix:
ANY DMAC
Any SMAC
Long Prefix:
ANY DMAC
Any SMAC
0x8880 0x0009
Bit 0
Internal Frame Header
DMAC
Bit 223
VLAN tag
0x8880 0x0009
Internal Frame Header
SMAC
Frame data
Bit 0
DMAC
SMAC
Frame data
Field removed before transmitted
Frames are injected without prefix from internal CPU or directly attached CPU.
Frames can be injected with a prefix to accommodate CPU injection from a front port (that may be
directly attached), controlled by ASM:CFG:PORT_CFG.INJ_FORMAT_CFG.
The internal frame header and optional prefix is removed before transmitting the frame on a port. It is
only visible to the user when injecting and extracting frames to or from the switch core and optionally
when sending/receiving frames using the NPI port.
It is possible to configure a port to transmit frames with internal frame headers using
REW:COMMON:PORT_CTRL.KEEP_IFH_SEL. It is also possible to only transmit CPU redirected
frames with Internal frame headers using REW:COMMON:GCPU_CFG.GCPU_KEEP_IFH.
3.2.2
Internal Frame Header Layout
The internal frame header is 28 bytes long. The following illustration shows the layout.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
15
Functional Descriptions
Figure 5 •
Internal Frame Header
DST_MODE:L3MC
DST_MODE:INJECT
DST_MODE:L3UC
DST_MODE:ENCAP
61
60
RT_FWD
SWAP_MAC
TAG_TPID
58
57
54
52
ERLEG
GEN_IDX
223
48
47
GEN_IDX_MODE
PROT_ACTIVE
46
45
44
ARRIVAL TSTAMP
PDU_W16_OFFSET
38
PDU_TYPE
35
34
192
191
CL_RSLT
23
DST PORT_MASK
19
18
NEXT_HOP_DMAC
L3MC_GRP_IDX
MPLS_TTL
DST
14
11
10
MPLS_SBIT
ERLEG
MPLS_TC
7
7
TYPE_AFTER_POP
COPY_CNT
5
4
W16_POP_CNT
0
0
0
128
127
0
FWD
AFI_INJECT
21
ES0_ISDX_KEY_ENA
19
VSTAX_AVAIL
UPDATE_FCS
17
16
15
14
DST_MODE
SFLOW_MARKING
AGED
RX_MIRROR
MIRROR_PROBE
12
11
10
9
VSTAX
7
6
SRC_PORT
DO_NOT_REW
MISC
1
0
15
48
47
PIPELINE_ACT
13
12
PIPELINE_PT
FWD
26
25
8
7
MISC
INJECT DPORT
/ EXTRACT
CPU_MASK
10
TAGGING
0
TAGGING
POP_CNT
QOS
TRANSP_DSCP
UPDATE_DSCP
Unused bits must be ignored and set to 0
QOS
8
7
0
1
0
7
6
5
DSCP
QOS
0
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
16
Functional Descriptions
The following table shows the internal frame header fields, including information whether a field is
relevant for injection, extraction, or both.
Table 3 •
Internal Frame Header Fields
Field Category
Field Name
Bit
Width
Description
TS
TSTAMP
223:192
32 bits
Arrival time stamp in nanoseconds.
DST when
FWD.DST_MODE is
INJECT
RSV
191:181
11 bits
Reserved field. Must be set to 0.
DST PORT_MASK
180:128
53 bits
Injection destination port mask where
each bit representing a physical port (only
used for injection).
DST when
FWD.DST_MODE is
ENCAP
RSV
191:190
2 bits
Reserved field. Must be set to 0.
RT_FWD
189
1 bit
Update IP4 TTL and chksum/ip6 Hopcnt.
SWAP_MAC
188
1 bit
Instruct rewriter to swap MAC addresses.
TAG_TPID
187:186
2 bits
Tag protocol IDs.
0: Standard TPID as specified in
VSTAX.TAG.TAG_TYPE.
1: custom1 stag TPID.
2: custom2 stag TPID.
3: custom3 stag TPID.
RSV
185:184
2 bits
Reserved field. Must be set to 0.
GEN_IDX
183:174
10 bit
Generic index.
VSI when GEN_IDX_MODE = 1.
GEN_IDX_MODE
173
1 bit
0: Reserved.
1: VSI.
PROT_ACTIVE
172
1 bit
Protect is active.
PDU_W16_OFFSET
171:166
6 bits
PDU WORD16 (= 2 bytes) offset from
W16_POP_CNT to Protocol data unit
(PDU).
PDU_TYPE
164:162
3 bits
PDU type used to handle OAM, PTP and
SAT.
0: None.
1: OAM_Y1731.
2: OAM_MPLS_TP.
3: PTP.
4: IP4_UDP_PTP.
5: IP6_UDP_PTP.
6: Reserved.
7: SAM_SEQ.
CL_RSLT
162:147
16 bits
Classified MATCH_ID combined from
VCAP CLM and VCAP IS2. Used if the
frame is forwarded to the CPU.
MPLS_TTL
146:139
8 bits
TTL value for possible use in MPLS label.
MPLS_SBIT
138
1 bit
SBIT of last popped MPLS label. for
possible use in MPLS label.
MPLS_TC
137:135
3 bits
TC value for possible use in MPLS label.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
17
Functional Descriptions
Table 3 •
Internal Frame Header Fields (continued)
Field Category
Field Name
Bit
Width
Description
DST when
FWD.DST_MODE is
ENCAP
TYPE_AFTER_POP
134:133
2 bits
0: ETH - Normal Ethernet header, starting
with DMAC.
1: CW.
First 4 bits:
4: IPv4 header.
6: IPv6 header.
Others: MPLS CW (see RFC 4385)
2: MPLS. MPLS shim header follows.
W16_POP_CNT
132:128
5 bits
Number of WORD16 (= 2 bytes) to be
popped by rewriter, starting from
beginning of frame.
DST when
FWD.DST_MODE is
“L3UC” (only used for
extraction)
RSV
191:183
9 bits
Reserved field. Must be set to 0.
ERLEG
182:176
7 bits
Egress router leg.
NEXT_HOP_DMAC
175:128
48 bits
Next hop DMAC. Only used for unicast
routing.
DST when
FWD.DST_MODE is
“L3MC” (only used for
extraction)
RSV
191:152
40 bits
Reserved field. Must be set to 0.
L3MC_GRP_IDX
151:142
10 bits
IP multicast group used for L3 multicast
copies.
ERLEG
141:135
7 bits
Egress router leg.
COPY_CNT
134:128
7 bits
Number of multicast routed copies. Only
used for multicast routing.
127:48
80 bits
VStaX. See VStaX Header, page 21.
VSTAX
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
18
Functional Descriptions
Table 3 •
Internal Frame Header Fields (continued)
Field Category
Field Name
Bit
Width
Description
FWD
AFI_INJ
47
1 bit
Injected into AFI.
RSV
46
1 bit
Reserved field. Must be set to 0.
ES0_ISDX_KEY_EN 45
A
1 bit
Controls use of ISDX in ES0 key.
RSV
44
1 bit
Reserved field. Must be set to 0.
VSTAX_AVAIL
43
1 bit
Received by ANA with valid VSTAX
section.
Extract: Frame received by ANA with valid
VSTAX section.
Inject: Frame to be forwarded based on
VSTAX section.
UPDATE_FCS
42
1 bit
Forces update of FCS.
0: Does not update FCS. FCS is only
updated if frame is modified by hardware.
1: Forces unconditional update of FCS.
RSV
41
1 bit
Reserved field. Must be set to 0.
DST_MODE
40:38
3 bits
Controls format of IFH.DST.
0: ENCAP
1: L3UC routing
2: L3MC routing
3: INJECT
Others: Reserved
SFLOW_MARKING
37
1 bit
Frame forwarded to CPU due to sFlow
sampling. Only valid for extraction.
AGED
36
1 bit
Must be set to 0. Set if frame is aged by
QSYS. Only valid for extraction.
RX_MIRROR
35
1 bit
Signals that the frame is Rx mirrored.
Only valid for extraction.
MIRROR_PROBE
34:33
2 bits
Signals mirror probe for mirrored traffic.
Only valid for extraction.
0: Not mirrored.
1-3: Mirror probe 0-2.
SRC_PORT
32:27
6 bits
Physical source port number.
May be set by CPU to non-CPU port
number to masquerade another port.
DO_NOT_REW
26
1 bit
Controlled by CPU or
ANA_CL:PORT:QOS_CFG.KEEP_ENA
and prevents the rewriter from making any
changes of frames sent to front ports
when set. Only valid for injection.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
19
Functional Descriptions
Internal Frame Header Fields (continued)
Table 3 •
Field Category
Field Name
Bit
Width
Description
MISC
PIPELINE_ACT
25:23
3 bits
Pipeline action specifies if a frame is
injected, extracted, or discarded.
0: None
1: INJ
2: INJ_MASQ
3: Reserved
4: XTR
5: XTR_UPMEP
6: LBK_ASM
7: LBK_QS
PIPELINE_PT
22:18
5 bits
Pipeline point specifies the location where
a frame is injected, extracted, or
discarded.
0: None
1: ANA_VRAP
2: ANA_PORT_VOE
3: ANA_CL
4: ANA_CLM
5: ANA_IPT_PROT
6: ANA_OU_MIP
7: ANA_OU_SW
8: ANA_OU_PROT
9: ANA_OU_VOE
10: ANA_MID_PROT
11: ANA_IN_VOE
12: ANA_IN_PROT
13: ANA_IN_SW
14: ANA_IN_MIP
15: ANA_VLAN
16: ANA_DONE
17: REW_IN_MIP
18: REW_IN_SW
19: RE_IN_VOE
20: REW_OU_VOE
21: REW_OU_SW
22: REW_OU_MIP
23: REW_SAT
24: REW_PORT_VOE
25: REW_VRAP
CPU_MASK
17:10
8 bits
CPU extraction queue mask.
POP_CNT
9:8
2 bits
Controlled by CPU or
ANA_CL:PORT:VLAN_CTRL.VLAN_POP
_CNT or CLM VLAN_POP_CNT_ENA
and causes the rewriter to pop the
signaled number of consecutive VLAN
tags. If ENCAP.W16_POP_CNT >0 and
TYPE_AFTER_POP = ETH POP_CNT
applies to inner Ethernet layer.
TAGGING
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
20
Functional Descriptions
Internal Frame Header Fields (continued)
Table 3 •
Field Category
Field Name
Bit
Width
Description
QOS
TRANSP_DSCP
7
1 bit
Controlled by CPU or
ANA_CL:PORT:QOS_CFG.
DSCP_KEEP_ENA and prevents the
rewriter from remapping DSCP values of
frames sent to front ports when set.
UPDATE_DSCP
6
1 bit
Controlled by CPU,
ANA_CL:PORT:QOS_CFG
DSCP_REWR_MODE_SEL, CLM
DSCP_ENA or ANA_CL:MAP_TBL:
SET_CTRL.DSCP_ENA and causes the
rewriter to update the frame’s DSCP value
with IFH.QOS.DSCP for frames sent to
front ports when set.
DSCP
5:0
6 bits
DSCP value.
The IFH is only used to control the rewriter on front ports or send to CPU. It is not transmitted with the
frame. For CPU ports, the information in the extraction IFH is for reference purposes only.
3.2.3
VStaX Header
When frames are sent to or from the NPI port, or when connecting multiple switches together, an optional
VStaX header is inserted into the frames.
The VStaX header consists of a 10-byte payload and is preceded by 2 bytes for the Microsemi EtherType
(0x8880). That is, a total of 12 bytes are inserted into the frame, as shown in the following illustration.
Figure 6 •
Frame With VStaX Header
FCS
Bit 79
Preamble
DMAC
SMAC
0x8880
Bit 0
VStaX Header, bit 79-0
Frame
Data
Microsemi EtherType
The layout of the 10-byte VStaX header is shown in the following illustration. In VStaX context, each
switch in a stack is termed a unit.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
21
Functional Descriptions
Figure 7 •
VStaX Header Layout
vstax2_isdx_ena=1 vstax2_isdx_ena=0
78
78
COSID
76
75
MUST BE 1
79
78
rsv
ISDX
68
67
MISC
AC
64
64
CL_DP
SP
CL_QOS
61
60
59
58
64
63
62
61
56
INGR_DROP_MODE 55
RSV
RSV
53
52
QOS
RSV
55
54
53
TTL
LRN_MODE
48
47
46
GENERAL
FWD_MODE
44
fwd_gmirror
fwd_stack
fwd_llookup
42
fwd_gcpu_all
RSV
TTL_KEEP
42
41
40
fwd_gcpu_ups
RSV
42
41
fwd_multicast
RSV
42
41
DST_UPSID
fwd_physical
RSV
fwd_logical
42 DST_PORT_TYPE 42
41
41
DST_UPSID
DST_UPSID
rsv
44
43
42
RSV
REW_CMD
36
35
DST_PN
32
RSV
37
36
35
DST_PN
DST_PN
32
32
37
36
37
36
MC_IDX
DST_PN
32
32
32
DST
CL_PCP
CL_DEI
32
31
31
29
28
27
TAG
CL_VID
16
15
14
13
INGR_PORT_TYPE
12
WAS_TAGGED
TAG_TYPE
port_type_intpn
port_type_upspn
SRC_PORT_TYPE 11 SRC_PORT_TYPE 11
12
11
rsv
SRC_ADDR_MODE 10
9
SRC_UPSID
RSV
Two values defined for src_intpn:
0xf: intpn_dlookup
0xe: intpn_router
src_glag
src_ind_port
src_ind_port
9
9
SRC
SRC_UPSID
5
4
3
5
4
SRC_GLAGID
0
SRC_UPSPN
SRC_INTPN
0
0
0
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
22
Functional Descriptions
The following table describes each field in the VStaX header.
VStaX Header Fields
Table 4 •
Field Category
Field Name
Bit
Width
Description
Reserved
RSV
79
1 bit
Reserved field. Must be set to 1 when injecting
frames and must be checked on extraction.
MISC when
COSID
ANA_AC:PS_COMMO
ISDX
N.VSTAX2_MISC_ISD
X_ENA=1
78:76
3 bits
Class of service.
75:64
12 bits
Ingress service index.
MISC when
RSV
ANA_AC:PS_COMMO
N.VSTAX2_MISC_ISD
AC
X_ENA=0
78:68
11 bits
Reserved field. Must be set to 0 when injecting
frames from CPU and ignored on extraction.
67:64
4 bits
GLAG aggregation code
Reserved
RSV
63:62
2 bits
Reserved field. Must be set to 0.
QOS
CL_DP
60:61
2 bits
Classified drop precedence level.
SP
59
1 bit
Super priority.
Identifies frames to be forwarded between CPUs
of neighboring units, using egress and ingress
super priority queues in the assembler and
disassembler.
CL_QOS (IPRIO)
58:56
3 bits
Classified quality of service value (internal
priority).
INGR_DROP_MOD 55
E
1 bit
Congestion management information.
0: Ingress front port is in flow control mode.
1: Ingress front port is in drop mode.
Reserved
RSV
54
1 bit
Reserved field. Must be set to 0.
General
RSV
53
1 bit
Reserved field. Must be set to 0.
TTL
52:48
5 bits
Time to live.
LRN_MODE
47
1 bit
0: Normal learning. SMAC and VID of the frame is
subject to learning.
1: Skip learning. Do not learn SMAC and VID of
the frame.
FWD_MODE
46:44
3 bits
Forward mode.
Encoding:
0x0: FWD_LLOOKUP: Forward using local lookup
in every unit.
0x1: FWD_LOGICAL: Forward to logical front port
at specific UPS.
0x2: FWD_PHYSICAL: Forward to physical front
port at specific UPS.
0x3: FWD_MULTICAST: Forward to ports part of
multicast group.
0x4: FWD_GMIRROR: Forward to global mirror
port.
0x5: FWD_GCPU_UPS: Forward to GCPU of
specific UPS.
0x6: FWD_GCPU_ALL: Forward to all GCPUs.
0x7: Reserved.
RSV
43
1 bit
Reserved field. Must be set to 0.
Reserved
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
23
Functional Descriptions
Table 4 •
VStaX Header Fields (continued)
Field Category
Field Name
Bit
Width
Description
VSTAX.DST when
REW_CMD
VSTAX.FWD_MODE is
FWD_LLOOKUP or
FWD_GMIRROR
42:32
11 bits
VCAP IS2 action REW_CMD.
VSTAX.DST when
DST_PORT_TYPE
VSTAX.FWD_MODE is
FWD_LOGICAL
42
1 bit
Destination port type. Encoding:
0: Front port
1: Internal port
DST_UPSID
41:37
5 bits
Destination unit port set ID.
DST_PN
36:32
5 bits
Logical destination port at unit identified by
dst_upsid.
VSTAX.DST when
RSV
VSTAX.FWD_MODE is
DST_UPSID
FWD_PHYSICAL
DST_PN
42
1 bit
Reserved field. Must be set to 0.
41:37
5 bits
Destination unit port set ID.
36:32
5 bits
Physical destination port at unit identified by
dst_upsid.
VSTAX.DST when
RSV
VSTAX.FWD_MODE is
MC_IDX
FWD_MULTICAST
42
1 bit
Reserved field. Must be set to 0.
41:32
10 bits
Forward to ports part of this multicast group index.
VSTAX.DST when
RSV
VSTAX.FWD_MODE is
DST_UPSID
FWD_GCPU_UPS
RSV
42
1 bit
Reserved field. Must be set to 0.
41:37
5 bits
Destination unit port set ID.
36
1 bit
Reserved field. Must be set to 0.
35:32
4 bits
CPU destination port at unit identified by
dst_upsid.
42
1 bit
Reserved field. Must be set to 0.
41
1 bit
Special TTL handling used for neighbor discovery.
40:36
5 bits
Reserved field. Must be set to 0.
DST_PN
35:32
4 bits
CPU destination port at unit identified by
dst_upsid.
CL_PCP
31:29
3 bits
Classified priority code point value.
CL_DEI
28
1 bit
Classified drop eligible indicator value.
CL_VID
27:16
12 bits
Classified VID.
WAS_TAGGED
15
1 bit
If set, frame was VLAN-tagged at reception.
TAG_TYPE
14
1 bit
Tag type.
0: C-tag (EtherType 0x8100).
1: S-tag (EtherType 0x88A8).
2 bits
Ingress ports type for private VLANs/Asymmetric
VLANs.
00: Promiscuous port.
01: Community port.
10: Isolated port.
DST_PN
VSTAX.DST when
RSV
VSTAX.FWD_MODE is
TTL_KEEP
FWD_GCPU_ALL
RSV
TAG
INGR_PORT_TYPE 13:12
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
24
Functional Descriptions
Table 4 •
VStaX Header Fields (continued)
Field Category
Field Name
SRC
3.3
Bit
Width
Description
SRC_ADDR_MODE 10
1 bit
0: src_ind_port:
Individual port. Source consists of src_upsid and
src_upspn.
1: src_glag: Source consists of src_glag.
SRC_PORT_TYPE
11
1 bit
Only applicable if src_addr_mode==src_ind_port.
Reserved and must be set to 0 if
src_addr_mode==src_glag.
0: port_type_upspn.
1: port_type_intpn.
SRC_UPSID
9:5
5 bits
If src_addr_mode = src_ind_port:
ID of stack unit port set, where the frame was
initially received.
SRC_UPSPN
4:0
5 bits
If src_addr_mode = src_ind_port and
src_port_type = port_type_upspn:
Logical port number of the port (on source ups),
where the frame was initially received.
SRC_INTPN
3:0
4 bits
If src_addr_mode = src_ind_port and
src_port_type = port_type_intpn:
Internal port number.
SRC_GLAGID
0
5 bits
If src_addr_mode = src_glag:
ID of the GLAG.
Port Numbering and Mappings
The switch core contains an internal port numbering domain where ports are numbered from 0 through
56. A port connects to a port module, which connects to SERDES macro, which connects to I/O pins on
the VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 devices. The port modules are DEV1G,
DEV2G5, or DEV10G. The interface macros are SERDES1G, SERDES6G, or SERDES10G.
Some ports are internal to the devices and do not connect to port modules or SERDES macros. For
example, internal ports are used for frame injection and extraction to the CPU queues.
The connections from ports to port modules to interface macros are flexible and depend on
configurations of quad SGMII (QSGMII) modes and 10G modes. This section describes the mappings
from port numbers to port modules, SERDES macros, and I/O pins, as well as the configurations
associated with these mappings.
The following table shows the default port numbering and how the ports map to port modules and
interface macros.
Table 5 •
Default Port Numbering and Port Mappings
Port Module
VSC7444-02
Port Module
VSC7448-02
Port Module
VSC7449-02
SERDES Macro
0
DEV1G_0
DEV1G_0
DEV1G_0
SERDES1G_1
1
DEV1G_1
DEV1G_1
DEV1G_1
SERDES1G_2
2
DEV1G_2
DEV1G_2
DEV1G_2
SERDES1G_3
3
DEV1G_3
DEV1G_3
DEV1G_3
SERDES1G_4
4
DEV1G_4
DEV1G_4
DEV1G_4
SERDES1G_5
5
DEV1G_5
DEV1G_5
DEV1G_5
SERDES1G_6
6
DEV1G_6
DEV1G_6
DEV1G_6
SERDES1G_7
Port Number
Port Module
VSC7442-02
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
25
Functional Descriptions
Default Port Numbering and Port Mappings (continued)
Table 5 •
Port Module
VSC7444-02
Port Module
VSC7448-02
Port Module
VSC7449-02
SERDES Macro
7
DEV1G_7
DEV1G_7
DEV1G_7
SERDES1G_8
8
DEV2G5_0
DEV2G5_0
DEV2G5_0
SERDES6G_0
9
DEV2G5_1
DEV2G5_1
DEV2G5_1
SERDES6G_1
10
DEV2G5_2
DEV2G5_2
DEV2G5_2
SERDES6G_2
11
DEV2G5_3
DEV2G5_3
DEV2G5_3
SERDES6G_3
Port Number
Port Module
VSC7442-02
12
DEV2G5_4
DEV2G5_4
DEV2G5_4
DEV2G5_4
SERDES6G_4
13
DEV2G5_5
DEV2G5_5
DEV2G5_5
DEV2G5_5
SERDES6G_5
14
DEV2G5_6
DEV2G5_6
DEV2G5_6
DEV2G5_6
SERDES6G_6
15
DEV2G5_7
DEV2G5_7
DEV2G5_7
DEV2G5_7
SERDES6G_7
16
DEV2G5_8
DEV2G5_8
DEV2G5_8
DEV2G5_8
SERDES6G_8
17
DEV2G5_9
DEV2G5_9
DEV2G5_9
DEV2G5_9
SERDES6G_9
18
DEV2G5_10
DEV2G5_10
DEV2G5_10
DEV2G5_10
SERDES6G_10
19
DEV2G5_11
DEV2G5_11
DEV2G5_11
DEV2G5_11
SERDES6G_11
20
DEV2G5_12
DEV2G5_12
DEV2G5_12
DEV2G5_12
SERDES6G_12
21
DEV2G5_13
DEV2G5_13
DEV2G5_13
DEV2G5_13
SERDES6G_13
22
DEV2G5_14
DEV2G5_14
DEV2G5_14
DEV2G5_14
SERDES6G_14
23
DEV2G5_15
DEV2G5_15
DEV2G5_15
DEV2G5_15
SERDES6G_15
24
DEV2G5_16
DEV2G5_16
DEV2G5_16
SERDES6G_16
25
DEV2G5_17
DEV2G5_17
DEV2G5_17
SERDES6G_17
26
DEV2G5_18
DEV2G5_18
DEV2G5_18
SERDES6G_18
27
DEV2G5_19
DEV2G5_19
DEV2G5_19
SERDES6G_19
28
DEV2G5_20
DEV2G5_20
DEV2G5_20
SERDES6G_20
29
DEV2G5_21
DEV2G5_21
DEV2G5_21
SERDES6G_21
30
DEV2G5_22
DEV2G5_22
DEV2G5_22
SERDES6G_22
31
DEV2G5_23
DEV2G5_23
DEV2G5_23
SERDES6G_23
48 (NPI)
DEV2G5_24
DEV2G5_24
DEV2G5_24
DEV2G5_24
SERDES1G_0
49
DEV2G5_25
DEV10G_0
DEV10G_0
DEV10G_0
SERDES10G_0
50
DEV2G5_26
DEV10G_1
DEV10G_1
DEV10G_1
SERDES10G_1
51
DEV2G5_27
DEV10G_2
DEV10G_2
SERDES10G_2
52
DEV2G5_28
DEV10G_3
DEV10G_3
SERDES10G_3
53 (CPU0)
No port module
No port module
No port module
No port module
No SERDES
54 (CPU1)
No port module
No port module
No port module
No port module
No SERDES
55 (VD0)
No port module
No port module
No port module
No port module
No SERDES
56 (VD1)
No port module
No port module
No port module
No port module
No SERDES
Ports 32 through 47 do not connect to SERDES macros in the default configuration. They are only
connected when QSGMII is enabled.
Ports 53 through 56 are internal ports are defined as follows:
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
26
Functional Descriptions
•
•
•
Port 53 and port 54: CPU port 0 and 1 (CPU0, CPU1) are used for injection and extraction of frames.
Port 55: Virtual device 0 (VD0) is used for multicast routing.
Port 56: Virtual device 1 (VD1) is used for AFI frame injections.
The internal ports do not have associated port modules and interface macros.
3.3.1
SERDES Macro to I/O Pin Mapping
The following table shows the fixed mapping from SERDES macros to the device I/O pins.
Table 6 •
SERDES Macro to I/O Pin Mapping
SERDES Macros
I/O Pin Names
SERDES1G_0 to SERDES1G_8
S0_T/RXN, S0_RXP, S0_TXN, S0_TXP S8_RXN, S8_RXP, S8_TXN, S8_TXP
SERDES6G_0 to SERDES6G_23
S9_RXN, S9_RXP, S9_TXN, S9_TXP S32_RXN, S32_RXP, S32_TXN, S32_TXP
SERDES10G_0 to SERDES10G_3 S33_RXN, S33_RXP, S33_TXN, S33_TXP S36_RXN, S36_RXP, S36_TXN, S36_TXP
3.3.2
Supported Port Interfaces
The devices support a range of physical port interfaces. The following table lists the interfaces supported
by the SERDES macros, as well as standards, data rates, connectors, medium, and coding for each port
interface.
In the functional descriptions, XAUI refers to any of the four-lane 10G modes, and SFI refers to any of the
serial 10G modes, unless noted.
Data Rate
Connector
Medium
Coding
SERDES6G
SERDES10G(1)
Supported Port Interfaces
SERDES1G
Table 7 •
IEEE 802.3, Clause 24 100M
125 Mbps
SFP
PCB
4B5B
x
x
x
SGMII
Cisco
1G
1.25 Gbps
PCB
8B10B
x
x
x
SFP
SFP-MSA
1G
1.25 Gbps
PCB
8B10B
x
x
x
1000BASE-KX
IEEE802.3, Clause 70
1G
1.25 Gbps
PCB,
backplane
8B10B
x
x
x
2.5G
Proprietary (aligned to
SFP)
2.5G
3.125 Gbps
PCB
8B10B
x
x
QSGMII
Cisco
5G
5 Gbps
PCB
8B10B
x
XAUI
IEEE 802.3, Clause 47 10G
4 × 3.125 Gbps
PCB,
backplane
8B10B
x
10GBASE-CX4 IEEE 802.3, Clause 54 10G
4 × 3.125 Gbps
Cable
8B10B
x
10GBASE-KX4 IEEE 803.3, Clause 71 10G
4 × 3.125 Gbps
PCB,
backplane
8B10B
x
RXAUI
CEI-OIF 6G-SR
2 × 6.25 Gbps
PCB,
backplane
8B10B
x
10GBASE-KR
IEEE 802.3, Clause 72 10G
1 × 10.3125 Gbps
PCB,
backplane
64B66B
Port Interface
Specification
100BASE-FX
Port
Speed
10G
SFP
XENPAK
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
x
27
Functional Descriptions
SFP+(SFI)
SFF-8431:
10G
Direct Attached Cu
IEEE 802.3, Clause 52
- LAN
1.
Data Rate
Connector
Medium
Coding
SFP+
PCB, cable 64B66B
SERDES10G(1)
Specification
SERDES6G
Port
Speed
Port Interface
SERDES1G
Supported Port Interfaces (continued)
Table 7 •
x
1 x 10.3125 Gbps
1 x 10.3125 Gbps
For VSC7442-02, SERDES10G supports only up to 1 Gbps.
3.3.3
QSGMII
Up to 12 of the SERDES6G macros can be configured QSGMII. This is enabled in
HSIO::HW_CFG.QSGMII_ENA per macro. When QSGMII is enabled for a SERDES6G macro, four port
modules are associated with the SERDES macro to form a QSGMII port with four 1G ports. The I/O
muxing related to QSGMII is shown in the following illustration.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
28
DEV1G_8
DEV1G_9
DEV1G_10
DEV1G_11
DEV1G_12
DEV1G_13
DEV1G_14
DEV1G_15
DEV1G_16
DEV1G_17
DEV1G_18
DEV1G_19
DEV1G_20
DEV1G_21
DEV1G_22
DEV1G_23
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
S29_TX/RXN/P
S30_TX/RXN/P
S31_TX/RXN/P
S32_TX/RXN/P
SERDES6G_20
SERDES6G_21
SERDES6G_22
SERDES6G_23
DEV2G5_20
DEV2G5_21
DEV2G5_22
DEV2G5_23
28
29
30
31
SERDES6G_16
SERDES6G_17
SERDES6G_18
SERDES6G_19
DEV2G5_16
DEV2G5_17
DEV2G5_18
DEV2G5_19
24
25
26
27
S21_TX/RXN/P
S22_TX/RXN/P
S23_TX/RXN/P
S24_TX/RXN/P
S25_TX/RXN/P
S26_TX/RXN/P
S27_TX/RXN/P
S28_TX/RXN/P
SERDES6G_12
SERDES6G_13
SERDES6G_14
SERDES6G_15
DEV2G5_12
DEV2G5_13
DEV2G5_14
DEV2G5_15
20
21
22
23
S17_TX/RXN/P
S18_TX/RXN/P
S19_TX/RXN/P
S20_TX/RXN/P
SERDES6G_8
SERDES6G_9
SERDES6G_10
SERDES6G_11
DEV2G5_8
DEV2G5_9
DEV2G5_10
DEV2G5_11
16
17
18
19
S13_TX/RXN/P
S14_TX/RXN/P
S15_TX/RXN/P
S16_TX/RXN/P
Q5 Q5 Q5 Q5
DEV2G5_4
DEV2G5_5
DEV2G5_6
DEV2G5_7
SERDES6G_4
SERDES6G_5
SERDES6G_6
SERDES6G_7
Q4 Q4 Q4 Q4
12
13
14
15
S9_TX/RXN/P
S10_TX/RXN/P
S11_TX/RXN/P
S12_TX/RXN/P
SERDES6G_0
SERDES6G_1
SERDES6G_2
SERDES6G_3
Q3 Q3 Q3 Q3
DEV2G5_0
DEV2G5_1
DEV2G5_2
DEV2G5_3
Q7 Q7 Q7 Q7
Q2 Q2 Q2 Q2
8
9
10
11
S5_TX/RXN/P
S6_TX/RXN/P
S7_TX/RXN/P
S8_TX/RXN/P
SERDES1G_5
SERDES1G_6
SERDES1G_7
SERDES1G_8
Q6 Q6 Q6 Q6
Q1 Q1 Q1 Q1
DEV1G_4
DEV1G_5
DEV1G_6
DEV1G_7
Q8 Q9 Q10Q11
4
5
6
7
S1_TX/RXN/P
S2_TX/RXN/P
S3_TX/RXN/P
S4_TX/RXN/P
Q4 Q5 Q6 Q7
DEV1G_0
DEV1G_1
DEV1G_2
DEV1G_3
SERDES1G_1
SERDES1G_2
SERDES1G_3
SERDES1G_4
Q0 Q0 Q0 Q0
Q0 Q1 Q2 Q3
0
1
2
3
Functional Descriptions
Figure 8 •
Table 8 •
QSGMII Muxing
Qn: HSIO::HW_CFG.QSGMII_ENA[n], n = 0 – 11
Port Numbers
The following table lists which ports, port modules, and SERDES macros are associated with each
QSGMII instance for the devices. Note that when a SERDES block is enabled for QSGMII, the default
port connections are removed. For example, if SERDES6G_4 is enabled for QSGMII, then port modules
DEV1G_0 through DEV1G_3 connect to SERDES6G_4, and the default connection from port 12 to
SERDES6G_4 through DEV2G5_4 is removed.
QSGMII Configurations
QSGMII
Number
Port
Numbers
Port Modules
VSC7442-02
Port Modules
VSC7444-02
Port Modules
VSC7448-02
Port Modules
VSC7449-02
0
0–3
DEV1G_0 to
DEV1G_3
DEV1G_0 to
DEV1G_3
DEV1G_0 to
DEV1G_3
DEV1G_0 to
DEV1G_3
SERDES6G_4
1
4–7
DEV1G_4 to
DEV1G_7
DEV1G_4 to
DEV1G_7
DEV1G_4 to
DEV1G_7
DEV1G_4 to
DEV1G_7
SERDES6G_5
2
8–11
DEV2G5_0 to
DEV2G5_3
DEV2G5_0 to
DEV2G5_3
DEV2G5_0 to
DEV2G5_3
DEV2G5_0 to
DEV2G5_3
SERDES6G_6
SERDES Macro
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
29
Functional Descriptions
Table 8 •
QSGMII Configurations (continued)
QSGMII
Number
Port
Numbers
Port Modules
VSC7442-02
Port Modules
VSC7444-02
Port Modules
VSC7448-02
Port Modules
VSC7449-02
3
12–15
DEV2G5_4 to
DEV2G5_7
DEV2G5_4 to
DEV2G5_7
DEV2G5_4 to
DEV2G5_7
DEV2G5_4 to
DEV2G5_7
SERDES6G_7
4
16–19
DEV2G5_8 to
DEV2G5_11
DEV2G5_8 to
DEV2G5_11
DEV2G5_8 to
DEV2G5_11
DEV2G5_8 to
DEV2G5_11
SERDES6G_8
5
20–23
DEV2G5_12 to
DEV2G5_15
DEV2G5_12 to
DEV2G5_15
DEV2G5_12 to
DEV2G5_15
DEV2G5_12 to
DEV2G5_15
SERDES6G_9
6
24–27
DEV2G5_16 to
DEV2G5_19
DEV2G5_16 to
DEV2G5_19
DEV2G5_16 to
DEV2G5_19
SERDES6G_10
7
28–31
DEV2G5_20 to
DEV2G5_23
DEV2G5_20 to
DEV2G5_23
DEV2G5_20 to
DEV2G5_23
SERDES6G_11
8
32–35
DEV1G_8 to
DEV1G_11
DEV1G_8 to
DEV1G_11
DEV1G_8 to
DEV1G_11
SERDES6G_12
9
36–39
DEV1G_12 to
DEV1G_15
DEV1G_12 to
DEV1G_15
DEV1G_12 to
DEV1G_15
SERDES6G_13
10
40–43
DEV1G_16 to
DEV1G_19
DEV1G_16 to
DEV1G_19
DEV1G_16 to
DEV1G_19
SERDES6G_14
11
44–47
DEV1G_20 to
DEV1G_23
DEV1G_20 to
DEV1G_23
DEV1G_20 to
DEV1G_23
SERDES6G_15
3.3.4
SERDES Macro
10G Modes
The 10G ports can be used in four different modes:
•
•
•
•
SFI mode The 10G port connects to a SERDES10G macro through a DEV10G port module
enabling 10G SFI.
XAUI mode The 10G port connects to four SERDES6G macro through a DEV10G port module
enabling four-lane XAUI.
RXAUI mode The 10G port connects to two SERDES6G macro through a DEV10G port module
enabling two-lane RXAUI.
1G/2.5G mode The 10G port connects to a SERDES10G macro through a DEV2G5 port module
enabling 1G and 2.5G port speeds.
The 10G modes are configurable per 10G port through HSIO::HW_CFG. The following illustration shows
an overview of the I/O muxing, associated port modules, and SERDES macros for one of the four 10G
ports. The muxing is similar for the remaining three 10G ports. For more information, see Table 9,
page 31.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
30
Functional Descriptions
S25_TX/RXN/P
S26_TX/RXN/P
S27_TX/RXN/P
S28_TX/RXN/P
S33_TX/RXN/P
SERDES6G_17
SERDES6G_18
SERDES6G_19
SERDES6G_0
HSIO
SERDES6G_16
10G Muxing
Figure 9 •
XGANA
XGDIG
XGXFI
HSIO::HW_CFG.DEV10G_0_MODE
XGKR0
XGKR1
1.25 Gbps
10.3125 Gbps
3.125 Gbps
6.25 Gbps
1.25 Gbps
1.25 Gbps
1.25 Gbps
1.25 Gbps
10GBASE-KR
Training
Backplane Ethernet
Auto-negotation
VAUI
DEV2G5
PCS1G
(SGMII)
PCS1G
(SGMII)
PCS1G
(SGMII)
PCS1G
(SGMII)
PCS_2X6G PCS_XAUI
(RXAUI)
(XAUI)
PCS_XFI
(SFI)
PCS1G
(SGMII)
KR FEC
MAC1G
MAC1G
MAC1G
MAC1G
DEV2G5_16
Port #24
DEV2G5_17
Port #25
DEV2G5_18
Port #26
DEV2G5_19
Port #27
MAC1G
MAC10G
PCS10G_BR
10G
DEV10G_0
Port #49
DEV2G5_25
Port #49 DEV2G5
Switch core
Register target
The following table shows how the 10G ports connect to port modules and to SERDES macros for the
different modes. Note that the XAUI and RXAUI 10G modes overrule the default port connections for the
associated SERDES6G macros.
10G Modes
Table 9 •
Port Module
VSC7444-02
Port Module
VSC7448-02
Port Module
VSC7449-02
SERDES Macros
49
DEV10G_0
DEV10G_0
DEV10G_0
SERDES10G_0
50
DEV10G_1
DEV10G_1
DEV10G_1
SERDES10G_1
51
DEV10G_2
DEV10G_2
SERDES10G_2
52
DEV10G_3
DEV10G_3
SERDES10G_3
10G Mode
Port Number
SFI
Port Module
VSC7442-02
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
31
Functional Descriptions
10G Modes (continued)
Table 9 •
Port Module
VSC7444-02
Port Module
VSC7448-02
Port Module
VSC7449-02
49
DEV10G_0
DEV10G_0
DEV10G_0
SERDES6G_16 to
SERDES6G_19
50
DEV10G_1
DEV10G_1
DEV10G_1
SERDES6G_20 to
SERDES6G_23
51
DEV10G_2
DEV10G_2
SERDES6G_8 to
SERDES6G_11
52
DEV10G_3
DEV10G_3
SERDES6G_12 to
SERDES6G_15
10G Mode
Port Number
XAUI
RXAUI
1G/2.5G
Port Module
VSC7442-02
SERDES Macros
49
DEV10G_0
DEV10G_0
DEV10G_0
SERDES6G_16,
SERDES6G_18
50
DEV10G_1
DEV10G_1
DEV10G_1
SERDES6G_20,
SERDES6G_22
51
DEV10G_2
DEV10G_2
SERDES6G_8,
SERDES6G_10
52
DEV10G_3
DEV10G_3
SERDES6G_12,
SERDES6G_14
49
DEV2G5_25
DEV2G5_25
DEV2G5_25
DEV2G5_25
SERDES10G_0
50
DEV2G5_26
DEV2G5_26
DEV2G5_26
DEV2G5_26
SERDES10G_1
51
DEV2G5_27
DEV2G5_27
DEV2G5_27
SERDES10G_2
52
DEV2G5_28
DEV2G5_28
DEV2G5_28
SERDES10G_3
For more information about the mapping from SERDES macros to I/O pins, see SERDES Macro to I/O
Pin Mapping, page 27.
3.3.5
VSC7442-02 Port Numbering and Port Mappings
VSC7442-02 has the following I/O constraints that must be obeyed when selecting port configurations:
•
•
Maximum of 52 ports excluding the 1G NPI port
Maximum of 52 Gbps total bandwidth excluding the 1G NPI port
The following table lists the available ports, port modules, and SERDES macros for VSC7442-02.
Table 10 •
Port
Numbers
VSC7442-02 Port Numbering and Port Mappings
Port Modules
SERDES Macros
0–47
DEV1G_0 to DEV1G_7
DEV2G5_0 to DEV2G5_23
DEV1G_8 to DEV1G_23
SERDES6G_4 to SERDES6G_15 QSGMII ports
Comments
48
DEV2G5_24
SERDES1G_0
1G NPI port
49–52
DEV2G5_25 to DEV2G5_28
SERDES10G_0 to
SERDES10G_3
1G SGMII ports
53–54
No port module
No port module
CPU ports
55
No port module
No port module
Virtual device 0 used for IP
multicasting
56
No port module
No port module
Virtual device 1 used for AFI frame
injections
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
32
Functional Descriptions
3.3.6
VSC7444-02 Port Numbering and Port Mappings
VSC7444-02 has the following I/O constraints that must be obeyed when selecting port configurations:
•
•
•
Maximum of 26 ports excluding the 1G NPI port.
Maximum of 60 Gbps total bandwidth excluding the 1G NPI port.
Maximum of 16 × 2.5G ports.
The following table lists the available ports, port modules, and SERDES macros for VSC7444-02.
Table 11 •
VSC7444-02 Port Numbering and Port Mappings
Port
Numbers
Port Modules
SERDES Macros
Comments
0–7
DEV1G_0 to DEV1G_7
SERDES1G_1 to SERDES1G_8
1G ports
8–23
DEV2G5_0 to DEV2G5_15
SERDES6G_0 to SERDES6G_15
1G or 2.5G ports
QSGMII can be enabled for
SERDES6G_4 to SERDES6G_9
48
DEV2G5_24
SERDES1G_0
1G NPI port
49–50
DEV10G_0 to DEV10G_1
SERDES10G_0 to SERDES10G_1 10G ports used in SFI mode
DEV10G_0 to DEV10G_1
SERDES6G_16 to SERDES6G_23 10G ports used in XAUI mode
DEV10G_0 to DEV10G_1
SERDES6G_16, SERDES6G_18,
SERDES6G_20, SERDES6G_22
DEV2G5_25 to DEV2G5_26
SERDES10G_0 to SERDES10G_1 10G ports used in 1G/2.5G mode
53–54
No port module
No port module
CPU ports
55
No port module
No port module
Virtual device 0 used for IP
multicasting
56
No port module
No port module
Virtual device 1 used for AFI frame
injections
3.3.7
VSC7448-02 Port Numbering and Port Mappings
10G ports used in RXAUI mode
VSC7448-02 has a maximum of 80 Gbps total bandwidth, excluding the 1G NPI port. This I/O constraint
must be obeyed when selecting port configurations:
The following table lists the available ports, port modules, and SERDES macros for VSC7448-02.
Table 12 •
VSC7448-02 Port Numbering and Port Mappings
Port
Numbers
Port Modules
SERDES Macros
Comments
0–7
DEV1G_0 to DEV1G_7
SERDES1G_1 to SERDES1G_8
1G ports.
8–31
DEV2G5_0 to DEV2G5_23
SERDES6G_0 to SERDES6G_23 1G or 2.5G ports.
All 24 ports can be used for 2.5G.
QSGMII can be enabled for
SERDES6G_4 to SERDES6G_15.
32–47
DEV1G_8 to DEV1G_23
48
DEV2G5_24
1G ports used when QSGMII is
enabled.
SERDES1G_0
1G NPI port.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
33
Functional Descriptions
Table 12 •
VSC7448-02 Port Numbering and Port Mappings (continued)
Port
Numbers
Port Modules
SERDES Macros
Comments
49–50
DEV10G_0 to DEV10G_1
SERDES10G_0 to
SERDES10G_1
10G ports used in SFI mode.
DEV10G_0 to DEV10G_1
SERDES6G_16 to
SERDES6G_23
10G ports used in XAUI mode.
DEV10G_0 to DEV10G_1
SERDES6G_16, SERDES6G_18, 10G ports used in RXAUI mode.
SERDES6G_20, SERDES6G_22
51–52
DEV2G5_25 to DEV2G5_26 SERDES10G_0 to
SERDES10G_1
10G ports used in 1G/2.5G mode.
DEV10G_2 to DEV10G_3
SERDES10G_2 to
SERDES10G_3
10G ports used in SFI mode.
DEV10G_2 to DEV10G_3
SERDES6G_8 to SERDES6G_15 10G ports used in XAUI mode.
DEV10G_2 to DEV10G_3
SERDES6G_8, SERDES6G_10,
SERDES6G_12, SERDES6G_14
10G ports used in RXAUI mode.
DEV2G5_27 to DEV2G5_28 SERDES10G_2 to
SERDES10G_3
10G ports used in 1G/2.5G mode.
53–54
No port module
No port module
CPU ports.
55
No port module
No port module
Virtual device 0 used for IP
multicasting.
56
No port module
No port module
Virtual device 1 used for AFI frame
injections.
3.3.8
VSC7449-02 Port Numbering and Port Mappings
VSC7449-02 has a maximum of 90 Gbps total bandwidth, excluding the 1G NPI port. This I/O constraint
must be obeyed when selecting port configurations.
The following table lists the available ports, port modules, and SERDES macros for VSC7449-02.
Table 13 •
VSC7449-02 Port Numbering and Port Mappings
Port
Numbers
Port Modules
SERDES Macros
Comments
0–7
DEV1G_0 to DEV1G_7
SERDES1G_1 to SERDES1G_8
1G ports.
8–31
DEV2G5_0 to DEV2G5_23
SERDES6G_0 to SERDES6G_23 1G or 2.5G ports.
All 24 ports can be used for 2.5G.
QSGMII can be enabled for
SERDES6G_4 to SERDES6G_15.
32–47
DEV1G_8 to DEV1G_23
48
DEV2G5_24
1G ports used when QSGMII is
enabled.
SERDES1G_0
1G NPI port.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
34
Functional Descriptions
Table 13 •
VSC7449-02 Port Numbering and Port Mappings (continued)
Port
Numbers
Port Modules
SERDES Macros
Comments
49–50
DEV10G_0 to DEV10G_1
SERDES10G_0 to
SERDES10G_1
10G ports used in SFI mode.
DEV10G_0 to DEV10G_1
SERDES6G_16 to
SERDES6G_23
10G ports used in XAUI mode.
DEV10G_0 to DEV10G_1
SERDES6G_16, SERDES6G_18, 10G ports used in RXAUI mode.
SERDES6G_20, SERDES6G_22
51 –52
DEV2G5_25 to DEV2G5_26 SERDES10G_0 to
SERDES10G_1
10G ports used in 1G/2.5G mode.
DEV10G_2 to DEV10G_3
SERDES10G_2 to
SERDES10G_3
10G ports used in SFI mode.
DEV10G_2 to DEV10G_3
SERDES6G_8 to SERDES6G_15 10G ports used in XAUI mode.
DEV10G_2 to DEV10G_3
SERDES6G_8, SERDES6G_10,
SERDES6G_12, SERDES6G_14
10G ports used in RXAUI mode.
DEV2G5_27 to DEV2G5_28 SERDES10G_2 to
SERDES10G_3
10G ports used in 1G/2.5G mode.
53–54
No port module
No port module
CPU ports.
55
No port module
No port module
Virtual device 0 used for IP
multicasting.
56
No port module
No port module
Virtual device 1 used for AFI frame
injections.
3.3.9
Logical Port Numbers
In many instances, the analyzer and the rewriter use a logical port number. For example, when link
aggregation is enabled, all ports within a link aggregation group must be configured to use the physical
port number of the port with the lowest port number within the group as logical port group ID. The
mapping to a logical port number is configured in ANA_CL:PORT:PORT_ID_CFG.LPORT_NUM and
REW::PORT_CTRL.ES0_LPORT_NUM.
3.4
SERDES1G
The SERDES1G is a high-speed SerDes interface that can operate at 1.25 Gbps (SGMII/SerDes,
1000BASE-KX). In addition, 100 Mbps (100BASE-FX) is supported by oversampling.
The SERDES1G supports the configuration of several parameters for increased performance in the
specific application environment. The features include:
•
•
•
3.5
Baudrate support 1.25 Gbps
Programmable loop bandwidth and phase regulation behavior for clock and data recovery unit
(CDR)
Input buffer (IB) and output buffer (OB) configurations supporting:
IB Signal Detect/Loss of Signal (LOS) options
IB equalization (including corner frequency configuration)
OB selectable de-emphasis
OB amplitude drive levels
OB slew rate control
SERDES6G
The SERDES6G is a high-speed SerDes interface, which can operate at the following data rates.
•
1.25 Gbps (SGMII/SerDes 1000BASE-KX)
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
35
Functional Descriptions
•
•
•
•
•
2.5 Gbps
3.125 Gbps (SerDes-lane-bitrate of a multilane aggregate; for example, XAUI, 10GBASE-KX4, or
10GBASE-CX4)
5 Gbps (QSGMII)
6.25 Gbps (SerDes-lane-bit rate of a double-data rate XAUI/RXAUI multilane aggregate)
100 Mbps (100BASE-FX) is supported by oversampling.
The SERDES6G supports the configuration of several parameters for increased performance in the
specific application environment. Features include:
•
•
•
•
•
3.6
Configurable baud rate support from 1.25 Gbps to 6.25 Gbps.
Programmable loop bandwidth and phase regulation behavior for clock and data recovery unit
(CDR)
Phase-synchronization of transmitter when used in multilane aggregates for low skew between
lanes
Input buffer (IB) and output buffer (OB) configurations supporting:
IB signal detect and loss of signal (LOS) options
IB adaptive equalization
OB programmable de-emphasis, 3 taps
OB amplitude drive levels
OB slew rate control
Loopbacks for system diagnostics
SERDES10G
The SERDES10G is a high-speed SERDES interface, which can operate from 1.25 Gbps up to
11.5 Gbps. Due to its frequency synthesizer any data rate between the limits above are supported.
100 Mbps (100MBASE-FX) is supported by oversampling.
The SERDES10G supports the configuration of several parameters for increased performance in the
specific application environment. The features include:
•
•
•
•
•
•
3.7
Configurable baud rate support from 1.25 Gbps to 11.5 Gbps
Programmable CDR loop filter bandwidth and phase regulation behavior for receiver
Programmable offset and phase adjustment of sampling stage
Transmitter to receiver synchronization including programmable jitter filtering/attenuation (< 0.01 Hz)
I/O buffer configurations supporting:
IB signal detect and loss of signal (LOS) options
IB adaptive equalization with high performance CTLE and 4-tap DFE
OB programmable de-emphasis, 3 taps
OB configurable amplitude drive levels
OB supply options (1.0 V or 1.2 V) for optimized drive strength
OB slew rate control
Loopbacks for system diagnostics
DEV1G and DEV2G5 Port Modules
The DEV1G and DEV2G5 port modules are essentially the same with identical configurations. The only
difference is the bandwidth of the bus connecting the port module to the assembler. A DEV2G5 port
module can forward data at 2.5 Gbps while the DEV1G port module can forward data at 1 Gbps. The
bandwidth of the port module is configured in the SERDES macro connecting to the port module.
3.7.1
MAC
This section describes the high level functions and configuration options of the Media Access controller
(MAC) used in the DEV1G and DEV2G5 port modules.
The DEV1G MAC supports 10/100/1000 Mbps in full-duplex mode and 10/100 Mbps in half-duplex
mode.
For the DEV2G5 MAC, the supported speeds and duplex modes depend on the following associated
SERDES macro:
•
SERDES1G: 10/100/1000 Mbps in full-duplex mode and 10/100 Mbps in half-duplex mode.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
36
Functional Descriptions
•
•
SERDES6G: 10/100/1000/2500 Mbps in full-duplex mode and 10/100 Mbps in half-duplex mode.
SERDES10G: 10/100/1000/2500 Mbps in full-duplex mode and 10/100 Mbps in half-duplex mode.
The following table lists the registers associated with configuring the MAC.
Table 14 •
DEV1G and DEV2G5 MAC Configuration Registers Overview
Register
Description
Replication
MAC_ENA_CFG
Enabling of Rx and Tx data paths
Per port module
MAC_MODE_CFG
Port mode configuration
Per port module
MAC_MAXLEN_CFG
Maximum length configuration
Per port module
MAC_TAGS_CFG
VLAN/service tag configuration
Per port module
MAC_TAGS_CFG2
VLAN/service tag configuration 2
Per port module
MAC_ADV_CHK_CFG
Configuration to enable dropping of Type/Length error frames
Per port module
MAC_IFG_CFG
Inter-frame gap configuration
Per port module
MAC_HDX_CFG
Half-duplex configuration
Per port module
MAC_STICKY
Sticky bit recordings
Per port module
3.7.1.1
Clock and Reset
There are a number of resets in the port module. All the resets can be set and cleared simultaneously. By
default, all blocks are in the reset state. With reference to DEV_RST_CTRL register, the resets are as
listed in the following table.
Table 15 •
DEV1G and DEV2G5 Reset
Register.Field
Description
DEV_RST_CTRL.MAC_RX_RST
Reset MAC receiver
DEV_RST_CTRL.MAC_TX_RST
Reset MAC transmitter
DEV_RST_CTRL.PCS_RX_RST
Reset PCS receiver
DEV_RST_CTRL.PCS_TX_RST
Reset PCS transmitter
When changing the MAC configuration, the port must go through a reset cycle. This is done by writing
register DEV_RST_CTRL twice. On the first write, the reset bits are set. On the second write, the reset
bits are cleared. The non-reset field DEV_RST_CTRL.SPEED_SEL must keep its new value for both
writes.
3.7.1.2
Interrupts
The following table lists the eight interrupt sources defined for DEV1G and DEV2G5 port modules. For
more information about general interrupt handling, see Interrupt Controller, page 367.
Table 16 •
DEV1G and DEV2G5 Interrupt Sources Register Overview
Register.Field
Description
DEV1G_INTR.FEF_FOUND_INTR_STICKY
Far-end-fault indication found
DEV1G_INTR.TX_LPI_INTR_STICKY
Low power idle transmit interrupt
DEV1G_INTR.RX_LPI_INTR_STICKY
Low power idle receive interrupt
DEV1G_INTR.AN_PAGE_RX_INTR_STICKY
New page event received by ANEG
DEV1G_INTR.AN_LINK_UP_INTR_STICKY
ANEG - Link status has changed to up
DEV1G_INTR.AN_LINK_DWN_INTR_STICKY
ANEG - Link status has changed to down
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
37
Functional Descriptions
Table 16 •
DEV1G and DEV2G5 Interrupt Sources Register Overview (continued)
Register.Field
Description
DEV1G_INTR.LINK_UP_INTR_STICKY
Link status is up
DEV1G_INTR. LINK_DWN_INTR_STICKY
Link status is down
3.7.1.3
Port Mode Configuration
The MAC provides a number of handles for configuring the port mode. With reference to the
MAC_MODE_CFG, MAC_IFG_CFG, and MAC_ENA_CFG registers, the handles are as listed in the
following table.
Table 17 •
DEV1G and DEV2G5 Port Mode Configuration Registers Overview
Register.Field
Description
MAC_MODE_CFG.FDX_ENA
Enables full-duplex mode
MAC_ENA_CFG.RX_ENA
Enables MAC receiver module
MAC_ENA_CFG.TX_ENA
Enables MAC transmitter module
MAC_IFG_CFG.TX_IFG
Adjusts inter frame gap in Tx direction
DEV_RST_CTRL.SPEED_SEL
Configures port speed and data rate
Clearing MAC_ENA_CFG.RX_ENA stops the reception of frames and further frames are discarded. An
ongoing frame reception is interrupted.
Clearing MAC_ENA_CFG.TX_ENA stops the dequeueing of frames from the egress queues, which
means that frames are held back in the egress queues. An ongoing frame transmission is completed.
TX inter-frame gap (MAC_IFG_CFG.TX_IFG) must be set according to selected speed and mode to
achieve 12 bytes IFG.
3.7.2
Half-Duplex Mode
The following special configuration options are available for half-duplex (HDX) mode.
•
•
•
•
3.7.2.1
Seed for back-off randomizer MAC_HDX_CFG.SEED seeds the randomizer used by the back-off
algorithm. Use MAC_HDX_CFG.SEED_LOAD to load a new seed value.
Retransmission of frame after excessive
collision MAC_HDX_CFG.RETRY_AFTER_EXC_COL_ENA determines whether the MAC
retransmits frames after an excessive collision has occurred. If set, a frame is not dropped after
excessive collisions, but the back-off sequence is restarted. This is a violation of IEEE 802.3, but is
useful in non-dropping half-duplex flow control operation.
Late collision timing Field MAC_HDX_CFG.LATE_COL_POS adjusts the border between a
collision and a late collision in steps of 1 byte. According to IEEE 802.3, section 21.3, this border is
permitted to be on data byte 56 (counting frame data from 1); that is, a frame experiencing a collision
on data byte 55 is always retransmitted, but it is never retransmitted when the collision is on byte 57.
For each higher LATE_COL_POS value, the border is moved 1 byte higher.
Rx-to-Tx inter-frame gap The sum of Fields MAC_IFG_CFG.RX_IFG1 and
MAC_IFG_CFG.RX_IFG2 establishes the time for the Rx-to-Tx inter-frame gap. RX_IFG1 is the first
part of half-duplex Rx-to-Tx inter-frame gap. Within RX_IFG1, this timing is restarted if carrier sense
(CRS) has multiple high-low transitions (due to noise). RX_IFG2 is the second part of half-duplex
Rx-to-Tx inter-frame gap. Within RX_IFG2, transitions on CRS are ignored.
Type/Length Check
The MAC supports frame lengths of up to 14,000 bytes. The maximum frame accepted by the MAC is
configurable and defined in MAC_MAXLEN_CFG.MAX_LEN.
The MAC allows 1/2/3 tagged frames to be 4/8/12 bytes longer respectively, than the specified maximum
length, with MAC_TAGS_CFG.VLAN_LEN_AWR_ENA. The MAC must be configured to look for VLAN
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
38
Functional Descriptions
tags (MAC_TAGS_CFG.VLAN_AWR_ENA). By default, EtherType 0x8100 and 0x88A8 are identified as
VLAN tags. In addition, three custom EtherTypes can be configured by MAC_TAGS_CFG.TAG_ID,
MAC_TAGS_CFG2.TAG_ID2, and MAC_TAGS_CFG2.TAG_ID3.
If a received frame exceeds the maximum length, the frame is truncated and marked as aborted.
The MAC can drop frames with in-range and out-of-range length errors by enabling
MAC_ADV_CHK_CFG.LEN_DROP_ENA.
3.7.3
Physical Coding Sublayer (PCS)
This section provides information about the Physical Coding Sublayer (PCS) block, where the autonegotiation process establishes mode of operation for a link. The PCS supports an SGMII mode and two
SerDes modes, 1000BASE-X and 100BASE-FX.
The following table lists the registers associated with the PCS.
Table 18 •
DEV1G and DEV2G5 PCS Configuration Registers Overview
Register
Description
Replication
PCS1G_CFG
PCS configuration
Per PCS
PCS1G_MODE_CFG
PCS mode configuration
Per PCS
PCS1G_SD_CFG
Signal Detect configuration
Per PCS
PCS1G_ANEG_CFG
Auto-negotiation configuration register
Per PCS
PCS1G_ANEG_NP_CFG
Auto-negotiation next page configuration
Per PCS
PCS1G_LB_CFG
Loopback configuration
Per PCS
PCS1G_ANEG_STATUS
Status signaling of PCS auto-negotiation process
Per PCS
PCS1G_ANEG_NP_STATUS
Status signaling of the PCS auto-negotiation next page process
Per PCS
PCS1G_LINK_STATUS
Link status
Per PCS
PCS1G_LINK_DOWN_CNT
Link down counter
Per PCS
PCS1G_STICKY
Sticky bit register
Per PCS
The PCS is enabled in PCS1G_CFG.PCS_ENA and PCS1G_MODE_CFG.SGMII_MODE_ENA selects
between the SGMII and SerDes mode. For information about enabling 100BASE-FX, see 100BASE-FX.
The PCS supports the IEEE 802.3, Clause 66 unidirectional mode, where the transmission of data is
independent of the state of the receive link (PCS1G_MODE_CFG.UNIDIR_MODE_ENA).
3.7.3.1
Auto-Negotiation
Auto-negotiation is enabled with PCS1G_ANEG_CFG.ANEG_ENA. To restart the auto-negotiation
process, PCS1G_ANEG_CFG.ANEG_RESTART_ONE_SHOT must be set.
In SGMII mode (PCS1G_MODE_CFG.SGMII_MODE_ENA = 1), matching the duplex mode with the link
partner must be ignored (PCS1G_ANEG_CFG.SW_RESOLVE_ENA). Otherwise the link is kept down
when the auto-negotiation process fails.
The advertised word for the auto-negotiation process (base page) is configured in
PCS1G_ANEG_CFG.ADV_ABILITY. The next page information is configured in
PCS1G_ANEG_NP_CFG.NP_TX.
When the auto-negotiation state machine has exchanged base page abilities, the
PCS1G_ANEG_STATUS.PAGE_RX_STICKY is asserted indicating that the link partner’s abilities were
received (PCS1G_ANEG_STATUS.LP_ADV_ABILITY).
If next page information need to be exchanged (only available in SerDes model, that is,
PCS1G_MODE_CFG.SGMII_MODE_ENA = 0), PAGE_RX_STICKY must be cleared, next page abilities
must be written to PCS1G_ANEG_NP_CFG.NP_TX, and
PCS1G_ANEG_NP_CFG.NP_LOADED_ONE_SHOT must be set. When the auto-negotiation state
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
39
Functional Descriptions
machine has exchanged the next page abilities, the PCS1G_ANEG_STATUS.PAGE_RX_STICKY is
asserted again indicating that the link partner’s next page abilities were received
(PCS1G_ANEG_STATUS.LP_NP_RX). Additional exchanges of next page information are possible
using the same procedure.
Next page engagement is coded in bit 15 of Base Page of Next page information.
After the last next page has been received, the auto-negotiation state machine enters the IDLE_DETECT
state, and the PCS1G_ANEG_STATUS.PR bit is set indicating that ability information exchange (base
page and possible next pages) has finished and software can now resolve priority. Appropriate actions,
such as Rx or Tx reset or auto-negotiation restart, can then be taken based on the negotiated abilities.
The LINK_OK state is reached one link timer period later.
When the auto-negotiation process reached the LINK_OK state,
PCS1G_ANEG_STATUS.ANEG_COMPLETE is asserted.
3.7.3.2
Link Surveillance
The current link status can be observed through PCS1G_LINK_STATUS.LINK_STATUS. The
LINK_STATUS is defined as either the PCS synchronization state or as bit 15 of
PCS1G_ANEG_STATUS.LP_ADV_ABILITY, which carries information about the link status in SGMII
mode.
Link down is defined as the auto-negotiation state machine being in neither the AN_DISABLE_LINK_OK
state nor the LINK_OK state for one link timer period. If a link down event occurred,
PCS1G_STICKY.LINK_DOWN_STICKY is set and PCS1G_LINK_DOWN_CNT is incremented. In
SGMII mode, the link timer period is 1.6 ms, whereas in SerDes mode, the link timer period is 10 ms.
The PCS synchronization state can be observed through PCS1G_LINK_STATUS.SYNC_STATUS.
Synchronization is lost when the PCS is not able to recover and decode data received from the attached
serial link.
3.7.3.3
Signal Detect
The PCS can be enabled to react to loss of signal through signal detect (PCS1G_SD_CFG.SD_ENA).
Upon loss of signal, the PCS Rx state machine is restarted, and frame reception stops. If signal detect is
disabled, no action is taken upon loss of signal. The polarity of signal detect is configurable in
PCS1G_SD_CFG.SD_POL.
The source of signal detect is selected in PCS1G_SD_CFG.SD_SEL to either the SerDes PMA or the
PMD receiver. If the SerDes PMA is used as source, the SerDes macro provides the signal detect. If the
PMD receiver is used as source, signal detect is sampled externally through one of the GPIO pins on the
VSC7442-02, VSC7444-02, and VSC7448-02 devices. For more information about the configuration of
the GPIOs and signal detect, see Link Surveillance, page 46.
PCS1G_LINK_STATUS.SIGNAL_DETECT contains the current value of the signal detect input.
3.7.3.4
Tx Loopback
For debug purposes, the Tx data path in the PCS can be looped back into the Rx data path. This is
enabled through PCS1G_LB_CFG.TBI_HOST_LB_ENA.
3.7.3.5
Test Patterns
The following table lists the DEV1G and DEV2G5 registers associated with configuring test patterns.
Table 19 •
DEV1G and DEV2G5 PCS Test Pattern Configuration Registers
Register
Description
Replication
PCS1G_TSTPAT_MODE_CFG
Test pattern configuration
Per PCS
PCS1G_TSTPAT_STATUS
Test pattern status
Per PCS
PCS1G_TSTPAT_MODE_CFG.JTP_SEL overwrites normal operation of the PCS and enables
generation of jitter test patterns for debug. The jitter test patterns are defined in IEEE 802.3, Annex 36A.
The following patterns are supported.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
40
Functional Descriptions
•
•
•
•
•
High frequency test pattern
Low frequency test pattern
Mixed frequency test pattern
Continuous random test pattern with long frames
Continuous random test pattern with short frames
The PCS1G_TSTPAT_MODE_STATUS register holds information about error and lock conditions while
running the jitter test patterns.
3.7.3.6
Low Power Idle
The following table lists the registers associated with Energy Efficient Ethernet (EEE) configuration and
status in PCS.
DEV1G and DEV2G5 PCS EEE Configuration Registers Overview
Table 20 •
Register
Description
Replication
PCS1G_LPI_CFG
Configuration of the PCS low power idle process
Per PCS
PCS1G_LPI_WAKE_ERROR_CNT
Wake error counter
Per PCS
PCS1G_LPI_STATUS
Low power idle status
Per PCS
The PCS supports Energy Efficient Ethernet (EEE) as defined by IEEE 802.3az. The PCS converts low
power idle (LPI) encoding between the MAC and the serial interface transparently. In addition, the PCS
provides control signals to stop data transmission in the SerDes macro. During low power idles, the serial
transmitter in the SerDes macro can be powered down, only interrupted periodically while transmitting
refresh information, which allows the receiver to notice that the link is still up but in power-down mode.
For more information about powering down the serial transmitter in the SerDes macro, see SERDES1G,
page 35 or SERDES6G, page 35.
It is not necessary to enable the PCS for EEE, because it is controlled indirectly by the shared queue
system. It is possible, however, to manually force the PCS into the low power idle mode through
PCS1G_LPI_CFG.TX_ASSERT_LPIDLE. During LPI mode, the PCS constantly encodes low power idle
with periodical refreshes. For more information about EEE, see Energy Efficient Ethernet, page 293.
The current low power idle state can be observed through PCS1G_LPI_STATUS for both receiver and
transmitter:
•
•
RX_LPI_MODE: Set if the receiver is in low power idle mode.
RX_QUIET: Set if the receiver is in the quiet state of the low power idle mode. If cleared while
RX_LPI_MODE is set, the receiver is in the refresh state of the low power idle mode.
The same is observable for the transmitter through TX_LPI_MODE and TX_QUIET.
If an LPI symbol is received, the RX_LPI_EVENT_STICKY bit is set, and if an LPI symbol is transmitted,
the TX_LPI_EVENT_STICKY bit is set. These events are sticky.
The PCS1G_LPI_WAKE_ERROR_CNT wake-up error counter increments when the receiver detects a
signal and the PCS is not synchronized. This can happen when the transmitter fails to observe the wakeup time or if the receiver is not able to synchronize in time.
3.7.3.7
100BASE-FX
The following table lists the registers associated with 100BASE-FX.
Table 21 •
DEV1G and DEV2G5 100BASE-FX Configuration Registers Overview
Register
Description
Replication
PCS_FX100_CFG
Configuration of the PCS 100BASE-FX mode
Per PCS
PCS_FX100_STATUS
Status of the PCS 100BASE-FX mode
Per PCS
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
41
Functional Descriptions
The PCS supports a 100BASE-FX mode in addition to the SGMII and 1000BASE-X SerDes modes. The
100BASE-X mode uses 4-bit/5-bit coding as specified in IEEE 802.3, Clause 24 for fiber connections.
The 100BASE-FX mode is enabled through PCS_FX100_CFG.PCS_ENA, which masks out all PCS1G
related registers.
The following options are available.
•
Far-End Fault facility: In 100BASE-FX, the PCS supports the optional Far-End Fault facility. Both
Far-End Fault Generation (PCS_FX100_CFG.FEFGEN_ENA) and Far-End Fault Detection
(PCS_FX100_CFG.FEFCHK_ENA) are supported. A Far-End Fault incident is recorded in
PCS_FX100_STATUS.FEF_FOUND.
Signal Detect: 100BASE-FX has a similar signal detect scheme as of the SGMII and SERDES
modes. For 100BASE-FX, PCS_FX100_CFG.SD_ENA enables signal detect, and
PCS_FX100_CFG.SD_SEL selects the input source. The current status of the signal detect input
can be observed through PCS_FX100_STATUS.SIGNAL_DETECT. For more information about
signal detect, see Signal Detect, page 40.
Link Surveillance: The PCS synchronization status can be observed through
PCS_FX100_STATUS.SYNC_STATUS. When synchronization is lost the link breaks and
PCS_FX100_STATUS.SYNC_LOST_STICKY is set. The PCS continuously tries to recover the link.
Unidirectional mode: 100BASE-FX has a similar unidirectional mode as for the SGMII and SerDes
modes, enabled through PCS_FX100_CFG.UNIDIR_MODE_ENA.
•
•
•
3.7.4
Port Statistics
Port statistics for DEV1G and DEV2G5 port modules are collected in the assembler and is accessed
through registers in the assembler.
3.8
DEV10G Port Module
The DEV10G port module can be used in the full-duplex operation modes listed in the following table.
Table 22 •
DEV10G Operation Modes
Lanes
PCS
Encoding Used
IPG
Shrink
(Avg)
Preamble
Shrink
Data
Bandwidth
Payload
Bandwidth1
3.125
4
8b/10b
PCS
XAUI
No
No
10 Gbps
10 Gbps
Standard
XAUI
RXAUI
6.25
2
8b/10b
PCS
XAUI
No
No
10 Gbps
10 Gbps
Proprietary,
but widely
supported
10G
stacking
3.125
4
8b/10b
PCS
XAUI
5 bytes
7 bytes
>10 Gbps
10 Gbps
Microsemi
only
SFI
10.3125 1
64b/66b
PCS
SFI
No
No
10 Gbps
10 Gbps
Standard
SFI
Mode
Lane
Speed
(Gbps)
XAUI
1.
Comment
Compensated for stacking header.
3.8.1
MAC
This section describes the high level functions and the configuration options of the Media Access
Controller (MAC) that is used in the DEV10G port modules.
The following table lists the registers associated with configuring the DEV10G MAC.
Table 23 •
DEV10G MAC Configuration Registers Overview
Register
Description
Replication
MAC_ENA_CFG
Enables of Rx and Tx data paths
Per port
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
42
Functional Descriptions
Table 23 •
3.8.1.1
DEV10G MAC Configuration Registers Overview (continued)
Register
Description
Replication
MAC_MODE_CFG
Port mode configuration
Per port
MAC_MAXLEN_CFG
Maximum length configuration
Per port
MAC_NUM_TAGS_CFG
Number of tags configuration
Per port
MAC_TAGS_CFG
VLAN/service tag configuration
Three per port
MAC_ADV_CHK_CFG
Advance Check Feature configuration
Per port
MAC_LFS_CFG
Link Fault Signaling configuration
Per port
MAC_LB_CFG
Loopback configuration
Per port
MAC_STICKY
Sticky bit recordings
Per port
Clock and Reset
There are a number of synchronous resets in the DEV10G port module. All of the resets can be set and
cleared simultaneously. By default, all blocks are in the reset state (reset active). The following tables
lists all available resets.
Table 24 •
DEV10G Reset Registers Overview
Target::Register.Field
Description
DEV10G::DEV_RST_CTRL.MAC_RX_RST Resets MAC receiver
DEV10G::DEV_RST_CTRL.MAC_TX_RST Resets MAC transmitter
DEV10G::DEV_RST_CTRL.PCS_RX_RST Resets PCS receiver
DEV10G::DEV_RST_CTRL.PCS_TX_RST Resets PCS transmitter
When changing the MAC configuration, the port must go through a reset cycle. This is done by writing
the register DEV10G::DEV_RST_CTRL twice. On the first write, all reset bits must be set to active (0x1).
On the second write, reset bits are cleared (0x0). Non-reset bits in DEV10G::DEV_RST_CTRL must
keep their value for both writes.
3.8.1.2
Interrupts
The following table lists the five interrupt sources defined for DEV10G port module. For more information
about general interrupt handling, see Interrupt Controller, page 367.
Table 25 •
DEV10G Interrupt Sources Registers Overview
Target::Register.Field
Description
DEV10G::INTR. PCS_BR_INTR
One of the Base-R PCS interrupt indications is active
DEV10G::INTR.TX_LPI_INTR
TX low power idle mode has changed
DEV10G::INTR.RX_LPI_INTR
RX low power idle mode has changed
DEV10G::INTR.LINK_UP_INTR
Link status is up
DEV10G::INTR. LINK_DWN_INTR
Link status is down
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
43
Functional Descriptions
All the sticky events in SFI PCS can generate an interrupt if their corresponding interrupt mask is set to 1.
The following table lists the interrupt registers that are used for interrupt generation if corresponding
event bit is set from 10GBASE-R PCS (or SFI PCS).
Table 26 •
3.8.1.3
DEV10G BASE-R PCS Interrupt Sources Registers Overview
Interrupt Mask Register
Interrupt Register Sticky Bit
Replication
PCS_INTR_MASK
SFI PCS sticky bits
Per PCS
KR_FEC_STICKY_MASK
KR FEC sticky bits
Per PCS
EEE_INTR_MASK
SFI PCS EEE sticky bits
Per PCS
Port Mode Configuration
The MAC provides a number of handles for configuring the port mode. The following table lists the
associated registers.
Table 27 •
DEV10G Port Mode Configuration Registers Overview
Target::Register.Field
Description
DEV10G::DEV_RST_CTRL.SPEED_SEL
Configures MAC and PCS Rx/Tx clock frequencies.
4: XAUI/RXAUI 10 Gbps.
6: Both MAC and PCS Rx/Tx clocks are disabled.
7: SFI 10 Gbps.
Unused values are reserved.
DEV10G::MAC_ENA_CFG.RX_ENA
Enable MAC receiver module.
DEV10G::MAC_ENA_CFG.TX_ENA
Enable MAC transmitter module.
DEV10G::MAC_MODE_CFG.TUNNEL_PAUSE_FRAMES
Enable tunneling of pause frames on a link.
DEV10G::MAC_MODE_CFG.MAC_PREAMBLE_CFG
Preamble format configuration.
DEV10G::MAC_MODE_CFG.MAC_IPG_CFG
IPG format configuration.
DEV10G::MAC_MODE_CFG. HIH_CRC_CHECK
Enable check for HiH checksum.
3.8.1.4
Type/Length Check
The MAC supports frame lengths of up to 14,000 bytes. The maximum frame accepted by the MAC is
configurable and defined in DEV10G::MAC_MAXLEN_CFG.MAX_LEN. Maximum length is automatically
adjusted if one or more tags are included in the current frame. The MAC allows 1/2/3 tagged frames to be
4/8/12 bytes longer respectively, than the specified maximum length.
DEV10G::MAC_MAXLEN_CFG.MAX_LEN_TAG_CHK configures whether the max Length check takes
the number of tags into consideration.
A number of tags can be selected by DEV10G::MAC_NUM_TAGS_CFG.NUM_TAGS. By default,
EtherType 0x8100 and 0x88A8 are identified as VLAN tags. In addition, three custom EtherTypes can be
configured by MAC_TAGS_CFG.TAG_ID.
If a received frame exceeds the maximum length, the frame is truncated and marked as aborted.
The MAC can drop the frames with length (in-range and out-of-range) errors by enabling
MAC_ADV_CHK_CFG.INR_ERR_ENA and MAC_ADV_CHK_CFG.OOR_ERR_ENA.
There are also other checks available that can be enabled based on configurations listed in the following
table.
Table 28 •
DEV10G Port Module Advance Checks Configuration Registers
Target::Register.Field
Description
DEV10G::MAC_ADV_CHK_CFG.EXT_EOP_CHK_ENA
Enables extended end of packet check.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
44
Functional Descriptions
Table 28 •
DEV10G Port Module Advance Checks Configuration Registers (continued)
Target::Register.Field
Description
DEV10G::MAC_ADV_CHK_CFG.EXT_SOP_CHK_ENA
Enable extended start of packet check.
DEV10G::MAC_ADV_CHK_CFG.SFD_CHK_ENA
Enable start-of-frame-delimiter check.
DEV10G::MAC_ADV_CHK_CFG.PRM_SHK_CHK_DIS
Disable preamble shrink check.
DEV10G::MAC_ADV_CHK_CFG.PRM_CHK_ENA
Enable preamble check.
DEV10G::MAC_ADV_CHK_CFG.OOR_ERR_ENA
Enable out-of-range error check.
DEV10G::MAC_ADV_CHK_CFG.INR_ERR_ENA
Enable in-range error check.
3.8.1.5
Local and Remote Fault Signaling
By default the MAC is configured to detect a Link Fault indication and react by transmitting the
appropriate sequence ordered set. The feature can be disabled completely using
DEV10G::MAC_LFS_CFG.LFS_MODE_ENA. It is also possible to configure MAC into unidirectional
mode according to IEEE 802.3, Clause 66, where frames are transmitted while receiving link fault
indication but interleaved by appropriate ordered sets in between
(DEV10G::MAC_LFS_CFG.LFS_UNIDIR_ENA).
3.8.2
Physical Coding Sublayer (PCS)
This section describes the Physical Coding Sublayer (PCS) blocks included in the DEV10G port module.
Depending on the DEV10G mode configuration, the corresponding PCS block must be selected and
configured accordingly. Status information, such as link status, is available per PCS block, and the
applicable register bit, depending on mode, must be checked. Interrupt source signal are selected from
the current selected PCS block depending on mode selection.
Note: Each DEV10G port module must only enable one PCS block at the same time.
The following table lists the applicable registers for DEV10G PCS configuration.
Table 29 •
DEV10G PCS Configuration Registers Overview
Register
Description
Replication
PCS_XAUI_CFG
XAUI-PCS configuration
Per PCS
PCS_XAUI_EXT_CFG
XAUI-PCS extended configuration
Per PCS
PCS_XAUI_SD_CFG
XAUI-PCS Signal Detect configuration
Per PCS
PCS_XAUI_TX_SEQ_CFG
XAUI-PCS sequence transmit configuration
Per PCS
PCS_XAUI_RX_ERR_CNT_CFG
XAUI-PCS error counter configuration
Per PCS
PCS_XAUI_INTERLEAVE_MODE_CFG
XAUI-PCS interleave mode (RXAUI) configuration
Per PCS
PCS_CFG
SFI-PCS configuration
Per PCS
PCS_SD_CFG
SFI-PCS signal detect configuration
Per PCS
The following table lists the applicable registers for DEV10G PCS status.
Table 30 •
DEV10G PCS Status Registers Overview
Register
Description
Replication
PCS_XAUI_RX_STATUS
XAUI-PCS receiver lane status
Per PCS
PCS_XAUI_DESKEW_STATUS
XAUI-PCS receiver deskew register
Per PCS
PCS_XAUI_CGALIGN_STATUS
XAUI-PCS receiver comma alignment register
Per PCS
PCS_XAUI_RX_SEQ_REC_STATUS
XAUI-PCS sequence receive status
Per PCS
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
45
Functional Descriptions
Table 30 •
DEV10G PCS Status Registers Overview (continued)
Register
Description
Replication
PCS_XAUI_RX_FIFO_OF_ERR_L0_CNT_STATUS
XAUI-PCS receive FIFO overflow error counter. Per PCS
PCS_XAUI_RX_FIFO_UF_ERR_L1_CNT_STATUS
XAUI-PCS receive FIFO underflow error
counter
Per PCS
PCS_XAUI_RX_FIFO_D_ERR_L2_CNT_STATUS
XAUI-PCS 10B8B decoder disparity error
counter
Per PCS
PCS_XAUI_RX_FIFO_CG_ERR_L3_CNT_STATUS XAUI-PCS 10B8B decoder codegroup error
counter
Per PCS
PCS_STATUS
SFI-PCS status
Per PCS
TX_ERRBLK_CNT
SFI-PCS counter for number of times transmit
FSM enters TX_E state
Per PCS
TX_CHARERR_CNT
SFI-PCS counter for number of invalid control
characters transmitter detected from MAC
Per PCS
RX_BER_CNT
SFI-PCS counter for number of times receive
BER FSM enters BER_BAD_SH state
(ber_count)
Per PCS
RX_ERRBLK_CNT
SFI-PCS counter for number of times receive
FSM enters RX_E state
Per PCS
RX_CHARERR_CNT
SFI-PCS counter for receive number of invalid
control characters after decoding
Per PCS
RX_OSET_FIFO_STAT
SFI-PCS receive ordered set FIFO status
Per PCS
RX_OSET_FIFO_DATA
SFI-PCS receive ordered set FIFO data
Per PCS
RX_FSET_FIFO_STAT
SFI-PCS receive F-Sig FIFO status
Per PCS
RX_FSET_FIFO_DATA
SFI-PCS receive F-Sig FIFO data
Per PCS
The RXAUI mode must be enabled in
DEV10G::PCS_XAUI_INTERLEAVE_MODE_CFG.ILV_MODE_ENA. The RXAUI mode offers the
following two byte-reordering methods:
•
•
Modified comma mode
Alignment ordered set mode
The RXAUI byte reordering mode can be selected by
DEV10G::PCS_XAUI_INTERLEAVE_MODE_CFG.ILV_MODE.
3.8.2.1
Backplane Auto-Negotiation
Backplane auto-negotiation must be used when normal auto-negotiation is disabled. For the DEV10G
port module there is no specific function or setup available.
3.8.2.2
Link Surveillance
For XAUI and RXAUI modes, current link status can be observed through
DEV10G::PCS_XAUI_RX_STATUS as follows:
All active lanes needs to be in alignment (DEV10G::PCS_XAUI_RX_STATUS.ALIGNMENT_STATUS) to
be able to receive correct data. If local fault indication is received this is flagged in
DEV10G::PCS_XAUI_RX_STATUS.LOCAL_FAULT_STICKY (1 bit per lane, only for active lanes).
Whenever synchronization was lost on an active lane or alignment status was lost sticky bits are set
(DEV10G::PCS_XAUI_RX_ERROR_STATUS.SYNC_LOST_STICKY and
DEV10G::PCS_XAUI_RX_ERROR_STATUS.ALIGNMENT_LOST_STICKY). On top there is an
additional sticky bit for received 8B10B codec errors
(DEV10G::PCS_XAUI_RX_ERROR_STATUS.C8B10B_ERR_STICKY).
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
46
Functional Descriptions
For SFI mode of operation, current link status can be observed through
PCS_10GBASE_R::PCS_STATUS defined as follows:
To receive correct data, the SFI PCS must achieve block lock
(PCS_10GBASE_R::PCS_STATUS.RX_BLOCK_LOCK). This block lock is achieved when PCS detects
a 66-bit boundary. Whenever the block lock is lost or achieved, a sticky bit is set
(PCS_10GBASE_R::PCS_INTR_STAT.LOCK_CHANGED_STICKY). Whenever a large number of false
sync headers is detected HI_BER (PCS_10GBASE_R::PCS_STATUS.RX_HI_BER) is asserted and a
sticky bit is set (PCS_10GBASE_R::PCS_INTR_STAT.RX_HI_BER_STICKY). If a local fault or remote
fault is received, it is flagged in PCS_10GBASE_R::PCS_INTR_STAT.RX_OSET_STICKY, and the
sequence ordered set received can be read from
PCS_10GBASE_R::RX_OSET_FIFO_DATA.RX_OSET_FIFO_DATA.
PCS_10GBASE_R::RX_FSET_FIFO_STAT can be used to know how many ordered sets are captured
and FIFO full status.
3.8.2.3
Signal Detect
The PCS can be enabled to react to loss of signal through signal detect (x_SD_CFG.SD_ENA). Upon
loss of signal, the PCS Rx state machine is restarted, and frame reception stops. If signal detect is
disabled, no action is taken upon loss of signal. The polarity of signal detect is configurable by
x_SD_CFG.SD_POL, where value of this bit indicates the active signal detect state of the selected input
line.
The source of signal detect is selected in x_SD_CFG.SD_SEL to either the SERDES PMA or the PMD
receiver. If the SERDES PMA is used as the source, the SERDES macro provides the signal detect. If
the PMD receiver is used as source, signal detect is sampled externally through one of the GPIO pins on
the VSC7442-02, VSC7444-02, and VSC7448-02 devices. For more information about the configuration
of the GPIOs and signal detect, see Parallel Signal Detect, page 356.
In above register bits x_SD_CFG stands for PCS_10GBASE_R::PCS_SD_CFG or
DEV10G::PCS_XAUI_SD_CFG, depending on SFI mode of operation or XAUI/RXAUI mode of
operation.
DEV10G::PCS_XAUI_RX_STATUS.SIGNAL_DETECT contains the current value of the signal detect
input.
3.8.2.4
Tx Loopback
For debug purposes, there is a loopback path defined within all PCS blocks that loops back Tx data path
into the Rx data path. This is enabled through DEV10G::PCS_XAUI_CFG. XAUI_LOOP_ENA for PCS
XAUI and through PCS_10GBASE_R::PCS_CFG.PMA_LOOPBACK_ENA for PCS SFI.
3.8.2.5
Test Patterns
The following table lists the registers associated with configuring XAUI/RXAUI PCS.
Table 31 •
DEV10G PCS Test Pattern Configuration Registers Overview
Target::Register.Field
Description
Replication
DEV10G::PCS_XAUI_TSTPAT_CFG
PCS XAUI: Test Pattern Generation Control
Per PCS
DEV10G::PCS_XAUI_TSTPAT_RX_SEQ_ PCS XAUI: Random Sequence Master
CNT_STATUS
Counter Random Sequence Master Counter
Per PCS
DEV10G::PCS_XAUI_TSTPAT_TX_SEQ_
CNT_STATUS
Per PCS
PCS XAUI: Jitter Pattern Transmit Counter.
Jitter Pattern Transmit Counter.
DEV10G::PCS_XAUI_TSTPAT_CFG.VT_GEN_ENA and
DEV10G::PCS_XAUI_TSTPAT_CFG.VT_GEN_SEL overwrites normal operation of the PCS XAUI and
enables generation of test pattern for debug. The PCS XAUI test pattern are defined in IEEE 802.3,
Annex 48A, and the following pattern are supported:
•
•
High frequency test pattern
Low frequency test pattern
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
47
Functional Descriptions
•
•
•
Mixed frequency test pattern
Continuous random test pattern
Continuous jitter test pattern
Test pattern checker can be enabled by DEV10G::PCS_XAUI_TSTPAT_CFG.VT_CHK_ENA and
DEV10G::PCS_XAUI_TSTPAT_CFG.VT_CHK_SEL where only mixed frequency test pattern, CR test
pattern and JC test pattern can be checked. High and Low frequency test pattern cannot be checked,
because acquiring synchronization state is not possible.
For frame-based test pattern (continuous random and continuous jitter) there are two counter
implemented: DEV10G::PCS_XAUI_TSTPAT_RX_SEQ_CNT_STATUS. RND_SEQ_TIMER is
incremented every 8th received symbol and is started with a detected start of frame symbol. Counter is
stopped when the last symbol of reference frame was compared. Idle phase between two frames is not
checked. DEV10G::PCS_XAUI_TSTPAT_TX_SEQ_CNT_STATUS.JP_TX_CNT counts the number of
transmitted frames. Both counters can be frozen prior to reading them by enabling
DEV10G::PCS_XAUI_TSTPAT_CFG.FREEZE_ERR_CNT_ENA.
The following table lists the registers associated with configuring SFI PCS
Table 32 •
DEV10G BASE-R PCS Test Pattern Configuration Registers Overview
Target::Register.Field
Description
Replication
PCS_10GBASE_R::PCS_CFG.TX_TEST_MODE
Enables test pattern mode in SFI PCS
transmitter.
Per PCS
PCS_10GBASE_R::PCS_CFG.TX_TEST_MODE
Enables test pattern mode in SFI PCS
receiver.
Per PCS
PCS_10GBASE_R::TEST_CFG
Test pattern configuration register when test Per PCS
mode is enabled for SFI PCS
PCS_10GBASE_R::TX_SEEDA_MSB.TX_SEEDA_MSB Most significant 26 bits of seed A used to
initialize SFI PCS scrambler in test mode.
Per PCS
PCS_10GBASE_R::TX_SEEDA_LSB.TX_SEEDA_LSB
Least significant 32 bits of seed A used to
initialize SFI PCS scrambler in test mode.
Per PCS
PCS_10GBASE_R::TX_SEEDB_MSB.TX_SEEDB_MSB Most significant 26 bits of seed B used to
initialize SFI PCS scrambler in test mode.
Per PCS
PCS_10GBASE_R::TX_SEEDB_LSB.TX_SEEDB_LSB
Per PCS
Least significant 32 bits of seed B used to
initialize SFI PCS scrambler in test mode.
PCS_10GBASE_R::TX_DATAPAT_MSB.TX_DATAPAT_ Most significant 32 bits of 64-bit data pattern Per PCS
MSB
used in pseudo-random and user-defined
test pattern mode for transmitter of SFI PCS.
PCS_10GBASE_R::TX_DATAPAT_LSB.TX_DATAPAT_L Least significant 32 bits of 64-bit data
SB
pattern used in pseudo-random and userdefined test pattern mode for transmitter of
SFI PCS.
Per PCS
PCS_10GBASE_R::RX_DATAPAT_MSB.RX_DATAPAT_ Most significant 32 bits of 64-bit data pattern Per PCS
MSB
used in pseudo-random and user-defined
test pattern mode for receiver of SFI PCS.
PCS_10GBASE_R::RX_DATAPAT_LSB.RX_DATAPAT_ Least significant 32 bits of 64-bit data
Per PCS
LSB
pattern used in pseudo-random and userdefined test pattern mode for receiver of SFI
PCS.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
48
Functional Descriptions
Table 32 •
DEV10G BASE-R PCS Test Pattern Configuration Registers Overview (continued)
Target::Register.Field
Description
PCS_10GBASE_R::PCS_STATUS.TESTPAT_MATCH
When in test pattern check mode, this bit will Per PCS
read 1 if the test pattern checker detects a
match. When 0, the test pattern does not
match. The test pattern error counts should
still be used along with this register bit to
determine proper test match status. The bit
will read back 1 only when the test pattern is
matching. This may happen even while test
pattern errors are counted on other clock
cycles.
PCS_10GBASE_R::TEST_ERR_CNT.TEST_ERR_CNT Count of detected test pattern errors in Rx
test pattern checker. Write 0 to clear.
Replication
Per PCS
By setting PCS_10GBASE_R::PCS_CFG.TX_TEST_MODE and
PCS_10GBASE_R::PCS_CFG.RX_TEST_MODE register bits to 1, test pattern mode is enabled in SFI
PCS. The following test patterns are supported as per IEEE 802.3, clause 49.2.8 and clause 49.2.12.
•
•
•
•
Square wave
Pseudo random
PRBS31
User defined
User-defined mode is a slightly modified test pattern in which the scrambler is not initialized with any
seed value, so there will be no errors after every 128-block window.
Different types of test pattern generation can be chosen by configuring
PCS_10GBASE_R::TEST_CFG.TX_TESTPAT_SEL and that of checkers by configuring
PCS_10GBASE_R::TEST_CFG.RX_TESTPAT_SEL. For square wave test pattern generation, period
can be configured using PCS_10GBASE_R::TEST_CFG.TX_SQPW_4B. For pseudo-random test
pattern inversion of seeds and data is enabled by PCS_10GBASE_R::TEST_CFG.TX_DSBL_INV and
PCS_10GBASE_R::TEST_CFG.RX_DSBL_INV.
3.8.2.6
Lane Swapping and Inversion
For easy back-to-back connection in stacking solutions it is possible either to invert all data signals
between PCS and connected SERDES macro as also flip the order of assigned SERDES macros to
lanes. The following table lists the applicable registers.
Table 33 •
DEV10G PCS XAUI Extend Configuration Registers Overview
Target::Register.Field
Description
DEV10G::PCS_XAUI_EXT_CFG.RX_INV_HMBUS
Invert all data signals from SERDES to PCS.
DEV10G::PCS_XAUI_EXT_CFG.RX_FLIP_HMBUS
Flip data in receive direction. For example, map lane 0 on 3,
lane 1 on 2, lane 2 on 1, and lane 3 on 0.
DEV10G::PCS_XAUI_EXT_CFG.TX_INV_HMBUS
Invert all data signals from PCS to SerDes.
DEV10G::PCS_XAUI_EXT_CFG.TX_FLIP_HMBUS
Flip data in transmit direction. For example, map lane 0 on 3,
lane 1 on 2, lane 2 on 1, and lane 3 on 0.
Data flip (for reverse ordering) at SFI PCS and SerDes interface can be achieved by configuring
PCS_10GBASE_R::PCS_CFG.TX_DATA_FLIP and PCS_10GBASE_R::PCS_CFG.RX_DATA_FLIP for
transmitter and receiver correspondingly.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
49
Functional Descriptions
3.8.2.7
Low Power Idle
The following table lists the configuration and status registers related to EEE in PCS.
DEV10G PCS EEE Configuration and Status Registers Overview
Table 34 •
Target::Register
Description
Replication
DEV10G::PCS_XAUI_LPI_CFG
Configuration of the XAUI PCS low power idle process.
Per PCS
DEV10G::PCS_XAUI_LPI_STATUS
XAUI PCS low power idle status.
Per PCS
PCS_10GBASE_R::EEE_STATUS
SFI PCS low power idle status.
Per PCS
PCS_10GBASE_R::WAKE_ERR_CNT
SFI PCS wake_error_counter value as specified in
IEEE 802.3az, clause 49.2.13.2.4.
Per PCS
3.8.2.8
KR FEC
SFI PCS also supports KR FEC. The following table lists the applicable registers.
Table 35 •
DEV10G KR FEC Configuration and Status Registers Overview
Register
Description
Replication
KR_FEC_CFG
KR FEC configuration register
Per PCS
KR_FEC_STATUS
KR FEC status
Per PCS
KR_FEC_STICKY
KR FEC sticky bits
Per PCS
KR_FEC_CORRECTED
KR FEC corrected error blocks counter
Per PCS
KR_FEC_UNCORRECTED
KR FEC uncorrected error blocks counter
Per PCS
To enable FEC, PCS_10GBASE_R::KR_FEC_CFG.FEC_ENA must be set. In addition, data bits must be
flipped at KR FEC interface with PCS. This is achieved by setting both
PCS_10GBASE_R::KR_FEC_CFG.TX_DATA_FLIP and
PCS_10GBASE_R::KR_FEC_CFG.RX_DATA_FLIP to 1.
For enabling FEC error indication in the PCS register bit, set
PCS_10GBASE_R::KR_FEC_CFG.ENABLE_ERROR_INDICATION to 1. This ensures that SFI PCS
decodes the block correctly, and hence correct data is presented to MAC. When FEC looses frame lock,
it is reflected in the PCS_10GBASE_R::KR_FEC_STICKY.FEC_FRAME_LOCK_STICKY sticky bit.
There are two counters in FEC for counting corrected and uncorrected error blocks. These are cleared
by writing a 1 to PCS_10GBASE_R::KR_FEC_CFG.RESET_MONITOR_COUNTERS, followed by a 0.
When the counters cross a threshold value configurable by
PCS_10GBASE_R::FIXED_ERROR_COUNT_THRESHOLD and
PCS_10GBASE_R::UNFIXABLE_ERROR_COUNT_THRESHOLD, two corresponding sticky bits are set
(PCS_10GBASE_R::KR_FEC_STICKY.FEC_FIXED_ERROR_COUNT_STICKY and
PCS_10GBASE_R::KR_FEC_STICKY.FEC_UNFIXABLE_ERROR_COUNT_STICKY).
Note: KR FEC must not be enabled when EEE is enabled. This mode is not supported.
3.8.3
Port Statistics
The DEV10G port module contains a set of port statistics. Packets counters are 32 bits wide and byte
counters are 40 bits wide. The following table lists the counters. The counters are writable. In particular,
the counters are cleared by writing a 0 to each counter.
Table 36 •
DEV10G Statistics Registers Overview
Register
Description
RX_SYMBOL_ERR_CNT
Rx symbol carrier error counter
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
50
Functional Descriptions
Table 36 •
DEV10G Statistics Registers Overview (continued)
Register
Description
RX_PAUSE_CNT
Rx pause frame counter
RX_UNSUP_OPCODE_CNT
Rx Control frame counter
RX_UC_CNT
Rx unicast frame counter
RX_MC_CNT
Rx multicast frame counter
RX_BC_CNT
Rx broadcast frame counter
RX_CRC_ERR_CNT
Rx CRC error counter
RX_UNDERSIZE_CNT
Rx undersize counter (valid frame format)
RX_FRAGMENTS_CNT
Rx undersize counter (CRC error)
RX_IN_RANGE_LEN_ERR_CNT
Rx in-range length error counter
RX_OUT_OF_RANGE_LEN_ERR_CNT
Rx out-of-range length error counter
RX_OVERSIZE_CNT
Rx oversize counter (valid frame format)
RX_JABBERS_CNT
Rx jabbers counter
RX_SIZE64_CNT
Rx 64 byte frame counter
RX_SIZE65TO127_CNT
Rx 65-127 byte frame counter
RX_SIZE128TO255_CNT
Rx 128-255 byte frame counter
RX_SIZE256TO511_CNT
Rx 256-511 byte frame counter.
RX_SIZE512TO1023_CNT
Rx 512-1023 byte frame counter.
RX_SIZE1024TO1518_CNT
Rx 1024-1518 byte frame counter.
RX_SIZE1519TOMAX_CNT
Rx 1519 to max. length byte frame counter.
RX_IPG_SHRINK_CNT
Rx Inter packet gap shrink counter.
TX_PAUSE_CNT
Tx Pause frame counter.
TX_UC_CNT
Tx unicast frame counter.
TX_MC_CNT
Tx multicast frame counter.
TX_BC_CNT
Tx broadcast frame counter.
TX_SIZE64_CNT
Tx 64 byte frame counter.
TX_SIZE65TO127_CNT
Tx 65-127 byte frame counter.
TX_SIZE128TO255_CNT
Tx 128-255 byte frame counter.
TX_SIZE256TO511_CNT
Tx 256-511 byte frame counter.
TX_SIZE512TO1023_CNT
Tx 512-1023 byte frame counter.
TX_SIZE1024TO1518_CNT
Tx 1024-1518 byte frame counter.
TX_SIZE1519TOMAX_CNT
Tx 1519 to maximum length byte frame counter.
RX_ALIGNMENT_LOST_CNT
Counter to track the dribble-nibble (extra nibble) errors in frames.
RX_TAGGED_FRMS_CNT
Counts frames that are tagged (C-tagged or S-tagged).
RX_UNTAGGED_FRMS_CNT
Counts frames that are Not tagged (neither C-tagged nor S-tagged).
TX_TAGGED_FRMS_CNT
Counts frames that are tagged (C-tagged or S-tagged).
TX_UNTAGGED_FRMS_CNT
Counts frames that are Not tagged (neither C-tagged nor S-tagged).
RX_HIH_CKSM_ERR_CNT
Rx HiH checksum error counter.
RX_XGMII_PROT_ERR_CNT
Rx XGMII protocol error counter.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
51
Functional Descriptions
3.9
Assembler
The assembler (ASM) block is responsible for collecting words from the smaller taxi bus and assembling
them into cells. It is also responsible for the loopback path between the rewriter and the analyzer.
For the first cell of a frame, which is the SOF cell, the assembler adds room for a 28-byte internal frame
header (IFH). On a stacking port, the stacking tag is extracted from the frame data and placed in the
respective part of the IFH.
The assembler receives a calendar sequence from the queue system defining in the sequence the ports
should be served on the outgoing cell bus.
The assembler also detects PAUSE frames and forwards the extracted PAUSE information to the
disassembler. PFC pause information extracted from PFC PAUSE frames are forwarded to the queue
system.
Finally, the assembler collects the port statistics for all lower speed ports, which are the DEV1G and
DEV2G5 ports. Statistics for the high-speed DEV10G ports are handled locally in the port module.
3.9.1
Setting Up a Port in the Assembler
The following table lists the port configuration registers within the assembler. Ethernet ports and CPU
ports are configured using the same registers. Some of the fields are only relevant for setting up a CPU
port (internal or external) and they will be covered in a later section.
Table 37 •
Port Configuration Register Overview
Target::Register.Field
Description
Replication
ASM::PORT_CFG.NO_PREAMBLE_ENA
Preamble configuration of incoming frames.
Per port
ASM::PORT_CFG.SKIP_PREAMBLE_ENA
Preamble configuration of incoming frames.
Per port
ASM::PORT_CFG.PAD_ENA
Enable padding.
Per port
ASM::PORT_CFG.INJ_DISCARD_CFG
Configures discard behavior for injected frames.
Per port
ASM::PORT_CFG.INJ_FORMAT_CFG
Configure format of injected frames.
Per port
ASM::PORT_CFG.VSTAX2_AWR_ENA
Enable VStaX stacking header awareness.
Per port
By default, an Ethernet port does not need configuration in the assembler as long as special settings are
not required. However, the following exceptions may apply:
If the port is used as a stacking port, set ASM::PORT_CFG.VSTAX2_AWR_ENA, which enables
detection of the VStaX stacking header. If a VStaX stacking header is found, the assembler will remove
the header from the frame and put it into the internal frame header.
Frames received from the port modules are preamble prepended by default. If a port module is
configured for preamble shrink mode, the ASM::PORT_CFG.NO_PREAMBLE_ENA must be set to 1,
because the port module does not prepend a preamble in this mode.
When ASM::PORT_CFG.PAD_ENA is set, frames that are smaller than 64 bytes are padded to reach the
minimum frame size.
The assembler has a built-in frame fragment detection mechanism for incoming frames that were started
but never received their EOF (because the port module was taken down, for example). These frames are
normally finalized by creating an EOF abort marked cell. If a frame has been discarded, it is noted in
ASM::PORT_STICKY.FRM_AGING_STICKY. The following table lists the port status register.
Table 38 •
Port Status Register Overview
Target::Register.Field
Description
Replication
ASM::PORT_STICKY.IFH_PREFIX_ERR_STICKY
Injection format mismatch sticky bit
Per port
ASM::PORT_STICKY.FRM_AGING_STICKY
Frame aging sticky bit
Per port
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
52
Functional Descriptions
3.9.2
Setting Up a Port for Frame Injection
Any front port and the internal CPU ports (ports 53-54) can be configured for frame injection. Frames that
are to be injected must have an IFH prepended the frame data. Optionally, the frame can further be
prepended an SMAC, a DMAC, and a VLAN tag. This results in the following three prefix formats for
injection frames:
•
•
•
Injection with long prefix
Injection with short prefix
Injection with no prefix
The injection format is selected in ASM::PORT_CFG.INJ_FORMAT_CFG. The prefix formats are shown
in the following illustration.
Figure 10 • Frame Injection Formats
Injection with long prefix:
Any DMAC
48 bits
Any SMAC
48 bits
Injection
VLAN tag
32 bits
Any SMAC
48 bits
8880 0007
16 bits 16 bits
8880 0007
16 bits 16 bits
IFH
224 bits
Original frame
Injection with short prefix:
Any DMAC
48 bits
IFH
224 bits
Original frame
Injection with no prefix:
IFH
224 bits
Original frame
Start-of-frame
For the long prefix, the incoming frame is matching against a programmable VLAN tag. The VLAN tag is
common for all ports. Only the VID and TPID fields of the VLAN tag are compared. The following table
lists the injection VLAN configuration register.
Table 39 •
Injection VLAN Register Overview
Target::Register.Field
Description
Replication
ASM::INJ_VLAN_CFG.INJ_VID_CFG
Injection tag VID
1
ASM::INJ_VLAN_CFG.INJ_TPID_CFG
Injection tag TPID
1
When a port is setup to receive frames with either a short prefix or a long prefix, the incoming frames are
checked against the selected prefix. If the prefix does not match, an error indication is set in
ASM::PORT_STICKY.IFH_PREFIX_ERR_STICKY. Depending on the setting of
ASM::PORT_CFG.INJ_DISCARD_CFG, the frames are processed in one of the three following modes.
•
•
•
None. Both compliant and non-compliant frames are forwarded. Compliant frames are forwarded
based on the IFH, and non-compliant frames are forwarded as regular frames.
Drop non-compliant. Compliant frames are forwarded based on the IFH, and non-compliant frames
are discarded.
Drop compliant. Compliant frame are discarded, and non-compliant frames are forwarded as normal
frames.
If a CPU port is used for frame injection, ASM::PORT_CFG.NO_PREAMBLE_ENA must be set to 1 so
that the assembler does not expect frame data to be prepended with a preamble.
If a front port is used for frame injection, ASM::PORT_CFG.SKIP_PREAMBLE_ENA must be set to 1 to
discard the preamble data before processing of the prepended injection header.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
53
Functional Descriptions
3.9.3
Setting Up MAC Control Sublayer PAUSE Frame Detection
The following table lists the PAUSE frame detection configuration registers in the assembler.
Table 40 •
PAUSE Frame Detection Configuration Register Overview
Target::Register.Field
Description
Replication
ASM::PAUSE_CFG.ABORT_PAUSE_ENA
Stop forwarding of PAUSE frames
Per port
ASM::PAUSE_CFG.ABORT_CTRL_ENA
Stop forwarding of MAC control frames
Per port
ASM::MAC_ADDR_HIGH_CFG.MAC_ADDR_HIGH
Bits 47-24 of DMAC address checked in
MAC_Control frames
Per port
ASM::MAC_ADDR_LOW_CFG.MAC_ADDR_LOW
Bits 23-0 of DMAC address checked in
MAC_Control frames
Per port
The assembler is responsible for detecting PAUSE frames and forwarding the PAUSE value to the
disassembler. Because PAUSE frames belong to the MAC control sublayer, they should in general be
filtered and not forwarded to a higher layer; that is, forwarded on the cell bus so they reach the analyzer.
The filtering is done by abort marking the frame.
The PAUSE frame and other MAC control frames can be forwarded to the analyzer. For PAUSE frame
forwarding, ASM::PAUSE_CFG.ABORT_PAUSE_ENA must be set to 0. For other MAC control frame
forwarding, ASM::PAUSE_CFG.ABORT_CTRL_ENA must be set to 0.
When PAUSE frames are received, the DMAC address is checked. The DMAC address must be either
the 48-bit multicast address 01-80-C2-00-00-01 as mentioned by IEEE802.3 Annex 31B.1 or the MAC
address of the port, which is configured in ASM::MAC_ADDR_HIGH_CFG.MAC_ADDR_HIGH and
ASM::MAC_ADDR_LOW_CFG.MAC_ADDR_LOW.
Note: The values configured in ASM::MAC_ADDR_HIGH_CFG.MAC_ADDR_HIGH and
ASM::MAC_ADDR_LOW_CFG.MAC_ADDR_LOW must match the value configured in
DSM::MAC_ADDR_BASE_HIGH_CFG.MAC_ADDR_HIGH and
DSM::MAC_ADDR_BASE_LOW_CFG.MAC_ADDR_LOW.
The number of received PAUSE frames is tracked as part of the port statistics. For more information, see
Setting Up Assembler Port Statistics, page 55.
3.9.4
Setting Up PFC
The PFC module of the assembler identifies PFC PAUSE frames by checking if the DMAC matches the
reserved multicast address 01-80-c2-00-00-01, the Type/Length field matches a MAC control frame
(0x8808), and the opcode is indicating a PFC frame (0x0101). Upon receiving a PFC PAUSE frame, the
assembler extracts and stores the timer information for all enabled priorities in the assembler PFC
timers. The PFC module generates a stop signal towards the queue system based on the current timer
values.
Detection of PFC frames is enabled by setting ASM::PFC_CFG.RX_PFC_ENA to 1 for the respective
(port,priority). When enabling PFC the current link speed for the port must be configured in
ASM::PFC_CFG.FC_LINK_SPEED for timing information to be evaluated correctly. The PFC
configuration registers are shown in the following table.
Table 41 •
PFC Configuration Register Overview
Target::Register.Field
Description
Replication
ASM::PFC_CFG.RX_PFC_ENA
Enable PFC per priority
Per port
ASM::PFC_CFG.FC_LINK_SPEED
Configure the link speed
Per port
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
54
Functional Descriptions
3.9.5
Setting Up Assembler Port Statistics
The assembler collects port statistics for all DEV1Gs and DEV2G5s. Statistics are also collected from the
disassembler and the assembler. Port statistics for DEV10Gs are not collected in the assembler and
must be looked up in each DEV10G separately.
The following table lists the port statistics configuration register in the assembler.
Table 42 •
Port Statistics Configuration Register Overview
Target::Register.Field
Description
Replication
ASM::STAT_CFG.STAT_CNT_CLR_SHOT
Statistics counter initialization.
1
ASM::PORT_CFG.CSC_STAT_DIS
Disables collection of statistics in the ASM.
Per port
Port statistics inside the ASM are stored in RAMs. Before they can be used, they must be initialized to 0
by setting ASM::STAT_CFG.STAT_CNT_CLR_SHOT to 1.
The statistic counters start counting as soon as the hardware has reset
ASM::STAT_CFG.STAT_CNT_CLR_SHOT to 0.
For information about the lists of port statistics registers available per port, see ASM:DEV_STATISTICS
register group in the Register List.
For the 10G capable ports, set ASM::PORT_CFG.CSC_STAT_DIS to 1 when the port is set up for
speeds faster than 2.5G, because the collection of statistics are handled locally in the DEV10G. For lower
speeds, the port uses a DEV2G5.
All statistic counters have a width of 32 bits, except for the five byte-counters; RX_IN_BYTES_CNT,
RX_OK_BYTES_CNT, RX_BAD_BYTES_CNT, TX_OUT_BYTES_CNT, and TX_OK_BYTES_CNT.
Those have an additional 4-bit MSB counter. When reading from counters with more than 32 bits, the
non-MSB part has to be read first in order to latch the MSB part into a shadow register, where the value
can be read afterward. For writing, the MSB part must be written first.
3.9.6
Setting Up the Loopback Path
Cells to be looped back by the assembler are received on a separate loopback cell bus interface from the
rewriter. The assembler merges the loopback data with data received from the ports onto the outgoing
cell bus towards the analyzer. Loopback data belongs to one of the three following types.
•
•
•
Virtual device 0 (VD0)
Virtual device 1 (VD1)
Front port loopback (LBK)
Each of the three loopback traffic types has its own FIFO. VD0 is accessed at register replication 0, VD1
at register replication 1, and LBK at register replication 2. The following table lists the loopback
configuration registers.
Table 43 •
Loopback FIFO Configuration Register Overview
Target::Register.Field
Description
Replication
ASM::LBK_FIFO_CFG.FIFO_FLUSH
Flush all data in the FIFO.
Per FIFO
ASM::VD_FC_WM.VD_FC_WM
Watermark for flow control towards the queue system.
Per VD FIFO
A FIFO can be flushed using the ASM::LBK_FIFO_CFG.FIFO_FLUSH register. The register field clears
itself when the flush is completed.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
55
Functional Descriptions
Cells in the FIFO can be discarded due to aging. If a frame is discarded due to aging, a per port sticky bit
is set in ASM::LBK_AGING_STICKY. The following table lists the loopback FIFO sticky bit registers.
Table 44 •
Loopback FIFO Sticky-Bit Registers Overview
Target::Register.Field
Description
ASM::LBK_AGING_STICKY.LBK_AGING_STICKY
Set if a frame has been discarded due to aging. 1
Per port bitmask.
Replication
ASM::LBK_OVFLW_STICKY.LBK_OVFLW_STICKY
Set if a frame have been discarded due to
overflow.
1
For VD0 and VD1, the loopback block pushes back towards the queue system to avoid FIFO overflows.
The watermark for configuring the FIFO level at which push back is active can be set in
ASM::VD_FC_WM.VD_FC_WM. The watermark can be configured individually for VD0 and VD1.
No flow control handling exists for the LBK FIFO. In case of overflow, all new cells received from the
rewriter are discarded, and a bit in the ASM::LBK_OVFLW_STICKY.LBK_OVFLW_STICKY sticky-bit
register is set.
3.10
Versatile Content-Aware Processor (VCAP™)
The Versatile Content-Aware Processor (VCAP™) is a content-aware packet processor that allows wirespeed packet inspection for rich implementation of, for example, advanced VLAN and QoS classification
and manipulations, IP source guarding, and security features for wireline and wireless applications. This
is achieved by programming rules into the VCAP.
When a VCAP is enabled, every frame passing though the switch is analyzed and multiple keys are
created based on the contents of the packet. The frame is examined to determine the frame type (for
example, IPv4 TCP frame), so that the frame information is extracted according to the frame type, portspecific configuration, and classification results from the basic classification. Keys are applied to the
VCAP and when there is a match between a key and a rule in the VCAP, the rule is then applied to the
packet from which the key was extracted.
A rule consists of an entry, an action, and a counter. Keys are matched against the entry of a rule. When
a rule is matched, the action is returned by the VCAP, and the rule’s counter is incremented.
One and only one rule will match a key. If a key matches more than one rule, the rule at the highest
address is selected. This means that a rule at high address takes priority over rules at lower addresses.
When a key does not match a rule, a default rule is triggered. A default rule’s action is programmable just
like regular rules. Some VCAPs have more than one default rule; which default rule to use is determined
at the same time as the key is created and applied to the VCAP.
This section provides information about entries and actions in general terms. When discussing an entry
or an action, it is considered a vector of bits that is provided by software. For information about building
classification matching (CLM) keys, see VCAP CLM Keys and Actions, page 73. For information about
building ingress stage 2 (IS2) keys, see VCAP IS2 Keys and Actions, page 147. For information about
building longest prefix matching (LPM) keys, see VCAP CLM Keys and Actions, page 73. For information
about building egress stage 0 (ES0) keys, see VCAP_ES0 Lookup, page 247.
The following sections describe how to program rules into the VCAPs of the devices. First, a general
description of configuration and VCAP operations is provided, including a description of wide VCAP
rules. Second, detailed information about individual VCAPs is provided. Finally, a few practical examples
illustrate how everything fits together when programming rules into VCAPs.
3.10.1
Configuring VCAP
Registers are available in two targets: VCAP_ES0 and VCAP_SUPER. Use VCAP_ES0 to configure the
VCAP ES0 target and the VCAP_SUPER target for all other VCAPs.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
56
Functional Descriptions
The following table lists the registers associated with VCAP_ES0 and VCAP_SUPER.
Table 45 •
VCAP_ES0 and VCAP_SUPER Registers
Register
Description
VCAP_UPDATE_CTRL
Initiates of read/write/move/initialization operations
VCAP_MV_CFG
Configures move/initialization operations
VCAP_CORE_IDX
Resource allocation, core index (does not apply to ES0)
VCAP_CORE_MAP
Resource allocation, mapping of cores (does not apply to ES0)
VCAP_ENTRY_DAT
Cache: Entry data
VCAP_MASK_DAT
Cache: Entry mask
VCAP_ACTION_DAT
Cache: Action
VCAP_CNT_DAT
Cache: Sticky-counter
VCAP_RULE_ENA
Cache: Rule enable (only applies to ES0)
A rule in the VCAP consists of an entry, action, and counter showing if the entry was hit. Rules are
accessed indirectly though a cache. The cache corresponds to one address in VCAP memory. Software
access the cache using the VCAP configuration registers VCAP_ENTRY_DAT, VCAP_MASK_DAT,
VCAP_ACTION_DAT, and VCAP_CNT_DAT.
The following illustration shows an example cache register mapping for a VCAP with 36-bit entry
data/mask, 70-bit action, and a 1-bit sticky counter. Cache registers are replicated to accommodate fields
that are wider than 32 bits. For example, if the entry size is 36 bits, bits [31:0] are accessed using
VCAP_ENTRY_DAT[0][31:0], and bits [35:32] are accessed using VCAP_ENTRY_DAT[1][3:0].
Figure 11 • VCAP Cache Layout Example
VCAP_ENTRY_DAT
idx: 1
32
idx: 0
0
don t care
64
Entry Data
36
VCAP_MASK_DAT
idx: 1
32
idx: 0
don t care
64
0
Entry Mask
36
32
VCAP_CNT_DAT
64
idx: 1
don t care
VCAP_ACTION_DAT
idx: 2
32
idx: 0
0
Action
70
idx: 0
don t care
96
0
Counter
1
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
57
Functional Descriptions
Entries have both entry data and entry mask fields. This allows a don’t-care of any bit position in the key
when matching a key against entries.
Table 46 •
Entry Bit Encoding
VCAP_ENTRY_DAT[n]/
VCAP_MASK_DAT[n]
Description
0/0
Bit n is encoded for the match-0 operation. When a key is applied to the VCAP, this bit in
the entry will match a 0 at position n in the key.
0/1
Bit n is encoded for match-any operation. When a key is applied to the VCAP, this bit in
the entry will match both 0 and 1 at position n in the key.
This encoding is sometimes referred to as don’t care.
1/0
Bit n is encoded for match-1 operation. When a key is applied to the VCAP, this bit in the
entry will match a 1 at position n in the key.
1/1
Bit n is encoded for match-off operation. The entry will never match any keys.
This encoding is not available in the VCAP ES0. Instead, it is treated as match-any.
When programming a rule that does not use all the available bits in the cache, remaining (undefined)
entry bits must be set to match-0, and action bits must be set to zeros.
To disable a rule, one or more bits in the entry is set to match-off. VCAP ES0 does not allow match-off
encoding. Rules are instead enabled and disabled by the VCAP_RULE_ENA.RULE_ENA cache field.
The counter for a rule is incremented when the entry of the rule is matched by a key. Counters that are
1-bit wide do not wrap, but instead saturate at 1.
3.10.1.1
Writing, Reading, and Initializing Rules
All access to and from VCAP memory goes through the cache.
To write a rule in the VCAP memory at address a: Entry data, entry action, and counter is first written to
the cache registers and then transferred into VCAP memory by triggering a write operation on the cache
by setting VCAP_UPDATE_CTRL.UPDATE_CMD = 0, VCAP_UPDATE_CTRL.UPDATE_ADDR = a,
and VCAP_UPDATE_CTRL.UPDATE_SHOT = 1. The UPDATE_SHOT field is cleared by hardware
when the rule has put into VCAP memory.
To read a rule from address a in the VCAP memory: Trigger a read operation on the cache by setting
VCAP_UPDATE_CTRL.UPDATE_CMD = 1, VCAP_UPDATE_CTRL.UPDATE_ADDR = a, and
VCAP_UPDATA_CTRL.UPDATE_SHOT = 1. The UPDATE_SHOT field is cleared by hardware when a
copy of the rule is available for reading via cache registers.
Active rules must not be overwritten by other rules (except when writing disabled rules). Software must
make sure that addresses are initialized before they are written.
It is possible to write the contents of the cache can be written to a range of addresses inside VCAP
memory. This is used during initialization of VCAP memory.
To write the contents of the cache to addresses a through b in VCAP memory, where a < b: Trigger an
initialization-operation by setting VCAP_MV_CFG.MV_NUM_POS = b-a. And
VCAP_UPDATE_CTRL.UPDATE_CMD = 4, VCAP_UPDATE_CTRL.UPDATE_ADDR = a, and
VCAP_UPDATE_CTRL.UPDATA_SHOT = 1. When the UPDATE_SHOT field is cleared, the addresses
have been overwritten with the contents of the cache.
The cache can be cleared by writing VCAP_UPDATE_CTRL.CLEAR_CACHE = 1. This immediately sets
the contents of the entry to disabled, action and counter is set to all-zeros.
VCAP_UPDATE_CTRL.CLEAR_CACHE can be set at the same time as triggering an write or
initialization operation, the cache will be cleared before writing to the VCAP memory.
It is possible to selectively disable access to entry, action, and/or counter during operations by setting
VCAP_UPDATE_CTRL.UPDATE_ENTRY_DIS, VCAP_UPDATE_CTRL.UPDATE_ACTION_DIS, or
VCAP_UPDATE_CTRL.UPDATE_CNT_DIS. These fields allow specialized operations such as clearing
counter values by performing initialization or write operations with disabled entry and action updating.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
58
Functional Descriptions
3.10.1.2
Moving a Block of Rules
The VCAP supports move operation for efficient and safe moving of rules inside VCAP memory. Moving
may be required to make room for new rules, because rules are prioritized by address.
To move n addresses from address a to address b in VCAP memory: Trigger a move-operation by setting
VCAP_MV_CFG.MV_NUM_POS = (a>b ? a-b : b-a), VCAP_MV_CFG.MV_SIZE = (n-1). And setting
VCAP_UPDATE_CTRL.UPDATE_CMD = (a>b ? 2 : 3), VCAP_UPDATE_CTRL.UPDATE_ADDR = a,
and VCAP_UPDATE_CTRL.UPDATE_SHOT = 1. When the UPDATE_SHOT field is cleared, the
contents of the addresses have been moved inside VCAP memory. The cache is overwritten during the
move-operation.
Rules must not be moved to a region that contains active rules. Software must make sure that
destination addresses are initialized before performing a move operation. After moving rules the move
operation leaves VCAP memory in initialized state, so overlapping source and destination regions is not
a problem during move operations.
3.10.1.3
Sharing Resources
The devices implement a shared pool of blocks that can be distributed freely among the CLM and IS2
VCAPs. The LPM can be assigned either no blocks or assigned one block. Each block in the pool has
4,096 addresses with entries, actions, and counters. The number of blocks available in the VCAP shared
pool depends on the device; VSC7442-02 has four blocks, VSC7444-02 has six blocks, and
VSC7448-02 and VSC7449-02 have eight blocks.
Blocks are located back-to-back in the VCAP memory space. Block 0 is assigned addresses 0 through
4,095; block 1 is assigned addresses 4,096 though 8,191; and so on. Prioritizing of rules based on
address still applies when multiple blocks are assigned to the same VCAP.
To simplify software development, all blocks assigned to the same VCAP should be allocated as one
consecutive region of addresses in memory. After a block of VCAP resources is allocated to a VCAP, it
cannot be reallocated. Resource assignment must be done during startup before the VCAPs are
enabled.
After reset, all VCAP resources default to unallocated power-down mode. To allocate a block from the
shared pool, write block index to VCAP_CORE_IDX.CORE_IDX, then map it to a specific interface by
writing VCAP_CORE_MAP.CORE_MAP. For more information, see the register description for encoding
of owners.
3.10.1.4
Bringing Up VCAP
The contents of the VCAP are unknown after reset. Software must initialize all addresses of the VCAP to
disabled entry and all-zeros in action and counter before enabling lookups.
The default rules of the VCAPs must also be initialized. After lookup is enabled for the VCAPs, default
rules are triggered and applied to frames.
Some VCAPs implement resource sharing. As a result, software must allocate resources as part of
VCAP bring up.
For more information about default addresses rules and resource allocation, see Individual VCAPs,
page 61.
3.10.2
Wide VCAP Entries and Actions
Some VCAPs support entries and actions that are wider than a single address in the VCAP memory. The
size of an entry or action is described as Xn, where n is the number of addresses that is taken up in
memory. When programming an X2 or larger entry or action, addresses are written one by one until the
entire entry or action is written to VCAP memory.
A rule consists of one entry and one action. The size of the rule is described as Xn where n is the largest
of entry or action widths. For example, a rule consisting of an X2 entry and an X4 action is considered to
be an X4 rule. The entry and action must start at the same address, so that address offset 0 for both
entry and action is located at the same address inside the VCAP memory.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
59
Functional Descriptions
When programming a rule where the action is wider than the entry, entry addresses exceeding the size of
the entry must be disabled. When the entry is wider than the action, action addresses exceeding the size
of the action must be set to zeros.
The starting address of an Xn rule must be divisible by n. This means that X1 rules may be placed at any
address, X2 rules may only placed at even addresses, X4 rules may only be placed at addresses
divisible by 4, and so on. During move-operations this puts a restriction on the distance that rules are
moved. In other words, when performing move-operation on a region of VCAP memory that contains
rules of X2 or larger size, the rules must still be at legal addresses after the move.
When a rule is matched by a key, the counter at address offset 0 is incremented.
When writing an X2 or larger rule, software must start with the highest address and end with the lowest
address. This is needed so that rules are not triggered prematurely during writing. When disabling rules,
software must start by disabling the lowest address. This is automatically handled when using the
initialization operation for disabling rules.
3.10.2.1
Type-Group Fields
A special type-group field is required to differentiate rules when a VCAP supports different sized entries
or actions. The type-group is not part of the entry/action description. Software has to manually lookup
and insert type-group field into entry/action data when writing rules to VCAP memory.
The type-group field is placed at the low bits of the entry and/or action. The value and width of the typegroup field differs between VCAPs and depends on the entry/action size of and the address offset into
the rule. For more information about type-group fields for individual VCAPs, see Individual VCAPs,
page 61.
The following illustration shows an example of inserting a 2-bit entry type-group field and a 3-bit action
type-group field for a VCAP with 36-bit entry data/mask and a 64-bit action. After inserting of type-group,
there is room for 34 additional entry/mask bits and 61 action bits in the cache.
Figure 12 • VCAP Cache Type-Group Example
idx: 1
32
36
2
idx: 1
idx: 0
VCAP_MASK_DAT
VCAP_ACTION_DAT
idx: 1
Entry Mask
2
36
64
Entry Data
0
E. TG Mask
32
don t care
64
0
32
idx: 0
0
A. TG
VCAP_ENTRY_DAT
idx: 0
E. TG
don t care
64
Action
3
When programming the entry’s type-group field, the mask bits must be set to zeros, so that the typegroup bits consist of match-1 or match-0, or both.
Use the following procedure for each address that is part of an entry.
1.
2.
Use the entry’s current address offset and size to find the appropriate type-group field and
associated field-width by using the entry type-group table for the VCAP. Skip step 2 if entry typegroup is not applicable for the VCAP.
Insert the entry type-group field into the cache for a type-group field width of n. Write the value of the
type-group field to bit-positions [n-1:0] in VCAP_ENTRY_DAT and write zeros to bit-positions [n-1:0]
in VCAP_MASK_DAT. In this way, type-group field value 1 becomes match-1 and 0 becomes
match-0.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
60
Functional Descriptions
3.
Fill the remainder of VCAP_ENTRY_DAT and VCAP_MASK_DAT with appropriate entry data. There
will be room for (entry width – type-group width) additional bits of entry data.
Use the following procedure for each address is that is part of an action.
1.
2.
3.
Use the action’s current address offset and size to find the appropriate type-group field and
associated field-width by using the action type-group table for the VCAP. Skip step 2 if action typegroup is not applicable for the VCAP.
Insert the action type-group field into the cache. For a type-group field width of n. Write the value of
the type-group field to bit positions [n-1:0] in VCAP_ACTION_DAT.
Fill the remainder of VCAP_ACTION_DAT with appropriate action data. There will be room for
(action width – type-group width) additional bits of action data.
Counters never use type-group encoding.
3.10.3
Individual VCAPs
This section provides detailed information about the individual VCAPs; VCAP CLM, VCAP IS2, VCAP
LPM, and VCAP ES0. The CLM, IS2, and LPM VCAPs share resources. For more information, see
Sharing Resources, page 59.
3.10.3.1
VCAP CLM
The following table lists the parameters that apply to the VCAP CLM.
Table 47 •
VCAP CLM Parameters
Parameter
Description
Number of VCAP addresses
4,096 per block that is allocated to this VCAP
Width of entry
36 bits per address
Width of action
70 bits per address
Counter type
1-bit saturating counter
Supported entry sizes
X1, X2, X4, X8, and X16
Supported action sizes
X1, X2, X4
Associated register target
VCAP_SUPER
The type-group field must be inserted into entries when programming rules, because the VCAP CLM
supports more than one entry size.
Table 48 •
VCAP CLM Entry Type-Group Fields
Address Offset
Size
Entry Type
Group
0
X1
0b1
Software must insert 1 bit with the value 1 into first address of
all X1 entries.
0
X2
0b10
Software must insert 2 bit with the value 2 into first address of
all X2 entries.
0
X4
0b100
Software must insert 3 bit with the value 4 into first address of
all X4 entries.
0
X8
0b1000
Software must insert 4 bit with the value 8 into first address of
all X8 entries.
0
X16
0b10000
Software must insert 5 bit with the value 16 into first address of
all X16 entries.
0b0
Software must insert 1 bit with the value 0 into uneven
addresses of all entries.
1, 3, 5, 7, 9, 11, 13,
and 15
Description
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
61
Functional Descriptions
Table 48 •
VCAP CLM Entry Type-Group Fields (continued)
Address Offset
Size
Entry Type
Group
Description
2, 6, 10, and 14
0b00
Software must insert 2 bit with the value 0 into addresses 2, 6,
10, and 14 of all entries.
4 and 12
0b000
Software must insert 3 bit with the value 0 into addresses 4
and 12 of all entries.
8
0b0000
Software must insert 4 bit with the value 0 into addresses 8 of
all entries.
The type-group field must be inserted into actions when programming rules, because the VCAP CLM
supports more than one action size.
Table 49 •
VCAP CLM Action Type-Group Fields
Address Offset
Size
Action Type Group
Description
0
X1
0b1
Software must insert 1 bit with the value 1 into first
address of all X1 actions.
0
X2
0b10
Software must insert 2 bit with the value 2 into first
address of all X2 actions.
0
X4
0b100
Software must insert 3 bit with the value 4 into first
address of all X4 actions.
1 and 3
0b0
Software must insert 1 bit with the value 0 into
uneven addresses of all actions.
2
0b00
Software must insert 2 bit with the value 0 into
address 2 of all actions.
It is possible to calculate the distribution of entry and action bits in the VCAP CLM based on entry and
action widths, together with the type-group field-widths.
Table 50 •
VCAP CLM Entry/Action Bit Distribution
Address offset
X1
X8
X16
0
e[34:0], a[68:0] e[33:0], a[67:0] e[32:0],
a[66:0]
e[31:0]
e[30:0]
e[67:33],
a[135:67]
e[66:32]
e[65:31]
2
e[101:68],
a[203:136]
e[100:67]
e[99:66]
3
e[136:102],
a[272:204]
e[135:101]
e[134:100]
4
e[168:136]
e[167:135]
5
e[203:169]
e[202:168]
6
e[237:204]
e[236:203]
7
e[272:238]
e[271:237]
1
X2
e[68:34],
a[136:68]
X4
8
e[303:272]
9
e[338:304]
10
e[372:339]
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
62
Functional Descriptions
Table 50 •
VCAP CLM Entry/Action Bit Distribution (continued)
Address offset
X1
X2
X4
X8
X16
11
e[407:373]
12
e[440:408]
13
e[475:441]
14
e[509:476]
15
e[544:510]
The VCAP CLM implements default rules. When submitting a key to the VCAP CLM, the analyzer
simultaneously decides which default rule to hit if the key does not match any entries in the VCAP. If no
resources (blocks) are assigned to VCAP CLM, there can be no matches. As a result, default rules will
be hit.
Table 51 •
VCAP
VCAP CLM Default Rule Addresses
Number of
Default Rules
Address
CLM0
114
Starting address of CLM0 default rule number n is (32,768 + n × 16).
CLM1
114
Starting address of CLM1 default rule number n is (34,592 + n × 16).
CLM2
114
Starting address of CLM2 default rule number n is (36,416 + n × 16).
3.10.3.2
VCAP IS2
The following table lists the parameters that apply to the VCAP IS2.
VCAP IS2 Parameters
Table 52 •
Parameter
Description
Number of VCAP addresses
4,096 per block that is allocated to this VCAP
Width of entry
36 bits per address
Width of action
70 bits per address
Counter-type
1-bit saturating counter
Supported entry sizes
X4, X8, X16
Supported action sizes
X4
Associated register target
VCAP_SUPER
The type-group field must be inserted into entries when programming rules, because the VCAP IS2
supports more than one entry size.
Table 53 •
VCAP IS2 Entry Type-Group Fields
Address Offset
Size
Entry
Type-Group
0
X4
0b1
Software must insert 1 bit with the value 1 into first address of all
X4 entries.
0
X8
0b10
Software must insert 2 bit with the value 2 into first address of all
X8 entries.
0
X16
0b100
Software must insert 3 bit with the value 4 into first address of all
X16 entries.
Description
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
63
Functional Descriptions
Table 53 •
VCAP IS2 Entry Type-Group Fields (continued)
Address Offset
Size
Entry
Type-Group
1, 2, 3, 5, 6, 7, 9, 10,
11, 13, 14, and 15
Description
Software must not insert type-group into addresses 1, 2, 3, 5, 6,
7, 9, 10, 11, 13, 14, and 15 for entries.
4 and 12
0b0
Software must insert 1 bit with the value 0 into addresses 4 and
12 of all entries.
8
0b00
Software must insert 2 bits with the value 0 into address 8.
Because only one action size is supported by the VCAP IS2, no type-group is inserted into actions when
programming rules.
It is possible to calculate the distribution of entry and action bits in the VCAP IS2 based on entry and
action widths together with the entry type-group field width.
Table 54 •
VCAP IS2 Entry/Action Bit Distribution
Address Offset
X4
X8
X16
0
e[34:0], a[69:0]
e[33:0]
e[32:0]
1
e[70:35],
a[139:70]
e[69:34]
e[68:33]
2
e[106:71],
a[209:140]
e[105:70]
e[104:69]
3
e[142:107],
a[279:210]
e[141:106]
e[140:105]
4
e[176:142]
e[175:141]
5
e[212:177]
e[211:176]
6
e[248:213]
e[247:212]
7
e[284:249]
e[283:248]
8
e[317:284]
9
e[353:318]
10
e[389:354]
11
e[425:390]
12
e[460:426]
13
e[496:461]
14
e[532:497]
15
e[568:533]
The VCAP IS3 has 58 default rules. The address of default rule number n is (38240 + 16 × n). When
submitting a key to the VCAP IS2, the analyzer simultaneously determines which default rule to hit if the
key does not match any entries. If no resources (blocks) were assigned to VCAP IS2, there can be no
matches and default rules will be hit.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
64
Functional Descriptions
3.10.3.3
VCAP LPM
The following table lists the parameters that apply to the VCAP LPM.
VCAP LPM Parameters
Table 55 •
Parameter
Description
Number of VCAP addresses
4,096 per block that is allocated to this VCAP
Width of entry
36 bit per address
Width of action
70 bit per address
Counter-type
1 bit saturating counter
Supported entry sizes
X1, X2, X4, X8
Supported action sizes
X1
Associated register target
VCAP_SUPER
The type-group field must be inserted into entries when programming rules, because the VCAP LPM
supports more than one entry size.
Table 56 •
VCAP LPM Entry Type-Group Fields
Address Offset
Size
Entry Type Group
Description
0
X1
0b1
Software must insert 1 bit with the value 1 into first
address of all X1 entries.
0
X2
0b10
Software must insert 2 bit with the value 2 into first
address of all X2 entries.
0
X4
0b100
Software must insert 3 bit with the value 4 into first
address of all X4 entries.
0
X8
0b1000
Software must insert 4 bit with the value 8 into first
address of all X8 entries.
1, 3, 5, and 7
0b0
Software must insert 1 bit with the value 0 into
uneven addresses of all entries.
2 and 6
0b00
Software must insert 2 bit with the value 0 into
addresses 2 and 6 of all entries.
4
0b000
Software must insert 3 bit with the value 0 into
addresses 4 of all entries.
Because only one action size is supported by the VCAP LPM, no type-group is inserted into actions
when programming rules.
It is possible to calculate the distribution of entry and action bits in the VCAP LPM based on entry and
action widths together with the entry type-group field width.
Table 57 •
VCAP LPM Entry/Action Bit Distribution
Address Offset
X1
X2
X4
X8
0
e[34:0], a[69:0]
e[33:0]
e[32:0]
e[31:0]
e[68:34]
e[67:33]
e[66:32]
2
e[101:68]
e[100:67]
3
e[136:102]
e[135:101]
1
4
e[168:136]
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
65
Functional Descriptions
Table 57 •
VCAP LPM Entry/Action Bit Distribution (continued)
Address Offset
X1
X2
X4
X8
5
e[203:169]
6
e[237:204]
7
e[272:238]
The VCAP LPM does not implement default rules. If the key does not match any entries, or if no
resources (blocks) are assigned to the VCAP LPM, routing lookups are treated as misses.
3.10.3.4
VCAP ES0
The VCAP ES0 has 4,096 addresses available.
The following parameters apply to the VCAP ES0.
Table 58 •
VCAP ES0 Parameters
Parameter
Description
Number of VCAP addresses
4,096.
Width of entry
35 bits per address.
Width of action
285 bits per address.
Counter-type
1-bit saturating counter.
Supported entry sizes
X1.
Supported action sizes
X1.
Associated register target
VCAP_ES0.
The type-group field is not used when programming entries and actions, because VCAP ES0 supports
only one entry size and one action size.
The following table shows the distribution of entry and action bits in the VCAP ES0.
Table 59 •
VCAP ES0 Entry/Action Bit Distribution
Address Offset
X1
0
e[29:0], a[284:0]
The VCAP ES0 has 53 default rules. The address of default rule number n is (4,096 + n). When
submitting a key to the VCAP ES0, the rewriter simultaneously decides which default rule to hit if the key
does not match any entries in the VCAP.
3.10.4
VCAP Programming Examples
This section provides examples of programming VCAP CLM and VCAP ES0.
3.10.4.1
Writing a Wide CLM Rule
This example shows how to write a CLM X4 rule, consisting of an X2 TRI_VID entry and an X4 FULL
action, to the CLM1 VCAP. In this example, the second and third blocks of VCAP resources have already
been mapped to CLM1.
When the second and third resource blocks are mapped to CLM1, it then owns VCAP address range
4096-12287. An X4 rule must be placed on an address inside memory owned by CLM1 and starting
addresses must be divisible by four, because it is an X4 rule. In this example, the X4 rule is written to
addresses 4484-4487.
Software is expected to track memory usage so that it only writes to VCAP memory that does not already
contain active rules. Deleting of rules is done by initializing the associated addresses.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
66
Functional Descriptions
The X2 TRI_VID entry is 69 bits wide. The X4 FULL action is 250 bits wide. For information about how to
build a FULL action, see VCAP CLM Actions, page 93. For information about how to build a TRI_VID
entry, see VCAP CLM X2 Key Details, page 77.
Each address holds 36 bits of entry data/mask, but some of them are used for type-group fields. For
more information about TRI_VID’s entry type-group field and entry bit-ranges for address offset 0 and 1,
Table 48, page 61 and Table 50, page 62. The results are shown in the following table.
Table 60 •
CLM X2 Entry Type-Group and Distribution Summary
Address
Type-Group Field
Entry Data/Mask Range
1412
0b10
[33:0]
1413
0b0
[68:34]
Note: The TRI_VID entry completely fills available entry space. If it had been less than 69 bits wide, then MSBs
at address offset 1 would have been treated as Match-0.
Each address holds 64 bits of action, but some of them are used for type-group fields. For more
information the FULL’s action type-group field and the action bit ranges for all four address offsets, see
Table 48, page 61 and Table 49, page 62. The results are shown in the following table.
Table 61 •
CLM X4 Entry Type-Group and Distribution Summary
Address
Type-Group Field
Entry Data/Mask Range
1412
0b100
[66:0]
1413
0b0
[135:67]
1414
0b00
[203:136]
1415
0b0
[249:204]
The FULL action is only 250 bits wide, so bits [272:250] of address offset 3 must be treated as zeros.
Software must write the highest address offset first and work down to the lowest address offset.
3.10.4.1.1 Writing Address Offset 3 of X4 Rule
Software is not allowed to modify the cache while VCAP operation is ongoing. Always check if
VCAP_UPDATE_CTRL.UPDATE_SHOT is cleared before starting to modify the cache. If a previous
operation is still ongoing, wait for the UPDATE_SHOT to clear.
When a new rule is started, first clear cache’s entry, action, and counter by setting
VCAP_UPDATE_CTRL.CLEAR_CACHE = 1.
The TRI_VID entry is an X2 entry and not part of address offset 3. The entry at this address must be set
to Match-off. This has already been achieved by clearing of the cache.
The FULL action is not so wide that it needs a third VCAP_ACTION_DAT replication, so the third
VCAP_ACTION_DAT replication must be set to zero, which was already achieved by clearing the cache.
Write action to cache: VCAP_ACTION_DAT[1][31:0] = zero-extend(action[249:235]),
VCAP_ACTION_DAT[0][31:1] = action[234:204], and VCAP_ACTION_DAT[0][0] = 0, because typegroup field for the X4 CLM action at address offset 3 is 0b0.
Write cache to VCAP memory by setting VCAP_UPDATE_CTRL = (4|(1415 5). IP options are not
parsed.
1
x
x
x
L3_DSCP
By default DSCP from frame. Per match, selectable to be current
classified DSCP (ANA_CL::ADV_CL_CFG.USE_CL_DSCP_ENA).
6
x
x
x
L3_IP4_DIP
IPv4 frames: Destination IPv4 address.
IPv6 frames: Destination IPv6 address, bits 31:0.
32
x
L3_IP4_SIP
Overloaded field for different frame types:
LLC frames (ETYPE_LEN=0 and IP_SNAP=0):
L3_IP4_SIP = [CTRL, PAYLOAD[0:2]]
32
x
CUSTOM_2
Field Name
NORMAL
VCAP CLM X8 Key Details (continued)
LL_FULL
Table 69 •
x
x
x
SNAP frames (ETYPE_LEN=0 and IP_SNAP=1):
L3_IP4_SIP = [PID[2:0], PAYLOAD[0]]
IPv4 frames (ETYPE_LEN=1, IP_SNAP=1, and IP4=1):
L3_IP4_SIP = source IPv4 address
IPv6 frames (ETYPE_LEN=1, IP_SNAP=1, IP4=0):
L3_IP4_SIP = source IPv6 address, bits 31:0
Other frames (ETYPE_LEN=1, IP_SNAP=0):
L3_IP4_SIP = PAYLOAD[0:3]
Note that - optionally - L3_IP4_SIP may contain the destination IP
address for IP frames, see DST_ENTRY.
L3_IP_PROTO
IPv4 frames (IP4=1): IP protocol.
IPv6 frames (IP4=0): Next header.
8
x
TCP_UDP
Frame type flag indicating the frame is a TCP or UDP frame.
Set if frame is IPv4/IPv6 TCP or UDP frame (IP protocol/next header
equals 6 or 17).
Overloading: Set to 1 for OAM Y.1731 frames.
1
x
x
x
TCP
Frame type flag indicating the frame is a TCP frame.
Set if frame is IPv4 TCP frame (IP protocol = 6) or IPv6 TCP frames
(Next header = 6).
1
x
x
x
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
87
Functional Descriptions
Size
L4_SPORT
TCP/UDP source port.
16
Overloading:
OAM Y.1731 frames: L4_SPORT = OAM MEL flags, see the following.
TCP_UDP is at the same time set to 1 to indicate the overloading.
x
x
CUSTOM_2
Description
NORMAL_5TUPLE_IP4
Field Name
NORMAL
VCAP CLM X8 Key Details (continued)
LL_FULL
Table 69 •
OAM MEL flags:
Encoding of MD level/MEG level (MEL). One bit for each level where
lowest level encoded as zero.
The following keys can be generated:
MEL=0: 0b0000000.
MEL=1: 0b0000001.
MEL=2: 0b0000011.
MEL=3: 0b0000111.
MEL=4: 0b0001111.
MEL=5: 0b0011111.
MEL=6: 0b0111111.
MEL=7: 0b1111111.
Together with the mask, the following kinds of rules may be created:
Exact match. Fx. MEL=2: 0b0000011.
Below. Fx. MEL=5: 0bXX11111.
Between. Fx. 3 0).
x
L3_FRAG_OFS_GT Set if IPv4 frame is fragmented but not the first fragment (Fragments Offset > 1
0
0)
x
L3_OPTIONS
Set if IPv4 frame contains options (IP len > 5). IP options are not parsed.
1
x
L3_DSCP
By default DSCP from frame. Per match, selectable to be current classified
DSCP (ANA_CL::ADV_CL_CFG.USE_CL_DSCP_ENA).
6
x
L3_IP6_DIP
Destination IP address.
IPv4 frames (IP4=1):
Bit 127: L3_FRAGMENT.
Bit 126: L3_FRAG_OFS_GT0.
Bit 125: L3_OPTIONS.
Bits 31:0: Destination IPv4 address.
128
x
L3_IP6_SIP
Source IP address.
IPv4 frames (IP4=1):
Bits 31:0: Source IPv4 address.
128
x
TCP_UDP
Frame type flag indicating the frame is a TCP or UDP frame.
1
Set if frame is IPv4/IPv6 TCP or UDP frame (IP protocol/next header equals 6
or 17).
Overloading:
Set to 1 for OAM Y.1731 frames.
x
TCP
Frame type flag indicating the frame is a TCP frame.
Set if frame is IPv4 TCP frame (IP protocol = 6) or IPv6 TCP frames (Next
header = 6).
x
1
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
92
Functional Descriptions
Field Name
Description
Size
L4_SPORT
TCP/UDP source port.
Overloading:
OAM Y.1731 frames: L4_SPORT = OAM MEL flags, see the following.
TCP_UDP is at the same time set to 1 to indicate the overloading.
OAM MEL flags:
Encoding of MD level/MEG level (MEL). One bit for each level where lowest
level encoded as zero.
The following keys can be generated:
MEL=0: 0b0000000
MEL=1: 0b0000001
MEL=2: 0b0000011
MEL=3: 0b0000111
MEL=4: 0b0001111
MEL=5: 0b0011111
MEL=6: 0b0111111
MEL=7: 0b1111111
Together with the mask, the following kinds of rules may be created:
Exact match. Fx. MEL=2: 0b0000011
Below. Fx. MEL=5: 0bXX11111
Between. Fx. 3 0)
Y
Y
N
Priority C-Tagged frames
accepted [port]
N
Y
These checks are available per S -tag TPID value. Four
values are supported: 0x88A8 (standard) and three
custom TPID values.
Discard
Y
N
Y
Y
Two VLAN tags required and
frame is single or untagged
C-Tagged
frames accepted
[port]
Y
Discard
Priority S-Tagged
frames accepted
[port]
Priority C-Tagged
Frame
Discard
N
N
Y
Discard
Discard
S-Tagged
frames accepted
[port]
N
N
Middle TAG =
S-TAG (VID > 0)
Middle TAG =
Priority S-TAG
N
Y
Y
Y
N
Middle TAG =
Priority C-TAG Accepted
[port]
N
Y
These checks are available per S -tag TPID value. Four
values are supported: 0x88A8 (standard) and three
custom TPID values.
Discard
Y
N
Y
Y
Three VLAN tags required and
frame is single, double or untagged
Middle TAG =
C-TAG accepted
[port]
Discard
Middle TAG =
Priority S-TAG Accepted
[port]
Y
Discard
N
Middle TAG =
Priority C-TAG
N
Y
Discard
Discard
Middle TAG =
S-TAG accepted
[port]
Middle TAG =
C-TAG (VID > 0)
N
N
Inner TAG =
S-TAG (VID > 0)
Inner TAG =
Priority S-TAG
N
Y
Y
N
Inner TAG =
C-TAG accepted
[port]
N
Inner TAG =
Priority C-TAG Accepted
[port]
Y
N
Discard
Inner TAG =
Priority S-TAG Accepted
[port]
Y
Discard
N
Inner TAG =
Priority C-TAG
N
Y
Discard
Y
Y
Discard
Inner TAG =
S-TAG accepted
[port]
Inner TAG =
C-TAG (VID > 0)
N
Y
These checks are available per S -tag TPID value. Four
values are supported: 0x88A8 (standard) and three
custom TPID values.
Frame accepted
The VLAN acceptance filter does not apply to untagged Layer 2 control protocol frames. They are always
accepted even when VLAN tags are required for other frames. The following frames are recognized as
Layer 2 control protocol frames:
•
•
•
Frames with DMAC = 0x0180C2000000 through 0x0180C200000F
Frames with DMAC = 0x0180C2000020 through 0x0180C200002F
Frames with DMAC = 0x0180C2000030 through 0x0180C200003F
Tagged Layer 2 control protocol frames are handled by the VLAN acceptance filter like normal tagged
frames and they must comply with the filter settings to be accepted.
Frames discarded by the frame acceptance filters are assigned PIPELINE_PT = ANA_CL and learning of
the frames’ source MAC addresses are at the same time disabled.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
103
Functional Descriptions
3.14.1.5
QoS, DP, and DSCP Classification
This section provides information about the functions in the QoS, DP, and DSCP classification. The three
tasks are described as one, because the tasks have functionality in common.
The following table lists the registers associated with QoS, DP, and DSCP classification.
Table 76 •
QoS, DP, and DSCP Classification Registers
Register
Description
Replication
ANA_CL:PORT:QOS_CFG
Configuration of the overall classification flow for
QoS, DP, and DSCP.
Per port
ANA_CL:PORT:PCP_DEI_MAP_CFG
Port-based mapping of (DEI, PCP) to (DP, QoS).
Per port per DEI per
PCP (16 per port)
ANA_CL::DSCP_CFG
DSCP configuration per DSCP value.
Per DSCP (64)
ANA_CL::QOS_MAP_CFG.
DSCP_REWR_VAL
DSCP rewrite values per QoS class.
Per QoS class (8)
ANA_CL::CPU_8021_QOS_CFG
Configuration of QoS class for Layer 2 control
protocol frames redirected to the CPU.
Per Layer 2 protocol
address (32)
The basic classification provides the user with control of the QoS, DP, and DSCP classification
algorithms. The result of the basic classification are the following frame properties:
•
•
•
The frame’s QoS class. This class is encoded in a 3-bit field, where 7 is the highest priority QoS
class and 0 is the lowest priority QoS class. The QoS class is used by the queue system when
enqueuing frames and when evaluating resource consumptions, for policing, statistics, and rewriter
actions. The QoS class is carried internally in the IFH field IFH.VSTAX.QOS.CL_QOS.
The frame’s DP level. This level is encoded in a 2-bit field, where frames with DP = 3 have the
highest probability of being dropped and frames with DP = 0 have the lowest probability. The DP
level is used by the MEF compliant policers for measuring committed and peak information rates, for
restricting memory consumptions in the queue system, for collecting statistics, and for rewriting
priority information in the rewriter. The DP level is incremented by the policers if a frame is
exceeding a programmed committed information rate. The DP level is carried internally in the IFH
field IFH.VSTAX.QOS.CL_DP.
The frame’s DSCP. This value is encoded in a 6-bit fields. The DSCP value is forwarded with the
frame to the rewriter where it is translated and rewritten into the frame. The DSCP value is only
applicable to IPv4 and IPv6 frames. The DSCP is carried internally in the IFH field IFH.QOS.DSCP.
The classifier looks for the following fields in the incoming frame to determine the QoS, DP, and DSCP
classification:
•
•
•
•
Priority Code Point (PCP) when the frame is VLAN tagged or priority tagged. There is an option to
use the inner tag for double tagged frames (VLAN_CTRL.VLAN_TAG_SEL).
Drop Eligible Indicator (DEI) when the frame is VLAN tagged or priority tagged. There is an option to
use the inner tag for double tagged frames (VLAN_CTRL.VLAN_TAG_SEL).
DSCP (all 6 bits, both for IPv4 and IPv6 packets). The classifier can look for the DSCP value behind
up to three VLAN tags. For non-IP frames, the DSCP is 0 and it is not used elsewhere in the switch.
Destination MAC address (DMAC) for L2CP frames. Layer 2 control protocol frames that are
redirected to the CPU are given a programmable QoS class independently of other frame properties.
The following illustration shows the flow chart of basic QoS classification.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
104
Functional Descriptions
Figure 15 • Basic QoS Classification Flow Chart
QoS class = DEFAULT_QOS_VAL[port]
DSCP = 0
Frame is IPv4 or IPv6"
Y
DSCP = Frame.DSCP
DSCP_TRANSLATE_ENA[port]
Y
DSCP = DSCP_TRANSLATE_VAL[DSCP]
DSCP_QOS_ENA[port]
Y
DSCP_TRUST_ENA[DSCP]
Y
Frame has inner tag and
PCP_DEI_QOS_ENA[port] and VLAN_TAG_SEL[port]
QoS class = DSCP_QOS_VAL[DSCP]
Y
QoS class = PCP_DEI_QOS_VAL[port][Frame.InnerDEI][Frame.InnerPCP]
Frame has outer tag and
PCP_DEI_QOS_ENA[port]
Y
QoS class = PCP_DEI_QOS_VAL[port][Frame.OuterDEI][Frame.OuterPCP]
Frame is BPDU
(DMAC = 0x0180C200000X)
and redirect to CPU
Y
QoS class = BPDU_QOS[DMAC[bits 3:0]]
Frame is GARP
(DMAC = 0x0180C200002X)
and redirect to CPU
Y
QoS class = GXRP_QOS[DMAC[bits 3:0]]
Frame is Y.1731/IEEE802.1ag
(DMAC = 0x0180C200003X)
and redirect to CPU
Y
QoS class = Y1731_AG_QOS[DMAC[bits 3:0]]
Basic classified QoS class (IFH.VSTAX.QOS.CL_QOS)
The following illustration shows the flow chart for basic DP classification.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
105
Functional Descriptions
Figure 16 • Basic DP Classification Flow Chart
DP = DEFAULT_DP_VAL[port]
DSCP = 0
Frame is IPv4 or IPv6"
Y
DSCP = Frame.DSCP
Y
DSCP_TRANSLATE_ENA[port]
Y
DSCP = DSCP_TRANSLATE_VAL[DSCP]
DSCP_DP_ENA[port]
Y
DSCP_TRUST_ENA[DSCP]
Y
Frame has inner tag and
PCP_DEI_DP_ENA[port] and VLAN_TAG_SEL[port]
DP = DSCP_DP_VAL[DSCP]
Y
DP = PCP_DEI_DP_VAL[port][Frame.InnerDEI][Frame.InnerPCP]
Frame has outer tag and
PCP_DEI_DP_ENA[port]
Y
DP = PCP_DEI_DP_VAL[port][Frame.OuterDEI][Frame.OuterPCP]
Frame is BPDU
(DMAC = 0x0180C200000X)
and redirect to CPU
Y
DP = 0
Frame is GARP
(DMAC = 0x0180C200002X)
and redirect to CPU
Y
DP = 0
Frame is Y.1731/IEEE802.1ag
(DMAC = 0x0180C200003X)
and redirect to CPU
Y
DP = 0
Basic classified DP
(IFH.VSTAX.QOS.CL_DP)
The following illustration shows the flow chart for basic DSCP classification.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
106
Functional Descriptions
Figure 17 • Basic DSCP Classification Flow Chart
DSCP = 0
Frame is IPv4 or IPv6"
Y
DSCP = Frame.DSCP
Y
DSCP_TRANSLATE_ENA[port]
Y
DSCP =
DSCP_TRANSLATE_VAL[DSCP]
DSCP_REWR_MODE_SEL[port] == Rewrite all or
DSCP_REWR_MODE_SEL[port] == Rewrite DSCP=0" and DSCP == 0 or
DSCP_REWR_MODE_SEL[port] == Rewrite selected and DSCP_REWR_ENA[DSCP]
Y
Basic classified QoS class
Basic classified DP level
DSCP = DSCP_REWR_VAL[8 x Basic classified DP level + Basic classified QOS class]
Basic classified DSCP
(IFH.QOS.DSCP)
Note that the DSCP translation part is common for both QoS, DP, and DSCP classification, and the
DSCP trust part is common for both QoS and DP classification.
The basic classifier has the option to overrule rewriter configuration (REW:PORT:DSCP_MAP) that
remaps the DSCP value at egress. When ANA_CL:PORT:QOS_CFG.DSCP_KEEP_ENA is set, the
rewriter is instructed not to modify the frame’s DSCP value (IFH.QOS.TRANSP_DSCP is set to 1).
The basic classified QoS, DP, and DSCP can be overwritten by more intelligent decisions made in the
VCAP CLM.
3.14.1.6
VLAN Classification
The following table lists the registers associated with VLAN classification.
Table 77 •
VLAN Configuration Registers
Register
Description
Replication
ANA_CL:PORT:VLAN_CTRL
Configures the port’s processing of VLAN information in Per port
VLAN-tagged and priority-tagged frames. Configures the
port-based VLAN.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
107
Functional Descriptions
Table 77 •
VLAN Configuration Registers (continued)
ANA_CL::VLAN_STAG_CFG
Configures custom S-tag TPID value.
3
ANA_CL:PORT:PCP_DEI_TRANS_CFG
Port-based translation of (DEI, PCP) to basic classified
(DEI, PCP).
Per port per
DEI per PCP
(16 per port)
ANA_CL:PORT:VLAN_TPID_CTRL.
BASIC_TPID_AWARE_DIS
Configures valid TPIDs for VLAN classification. This
configuration is shared with routing tag control.
Per port
The VLAN classification determines the following set of VLAN parameters for all frames:
•
•
•
•
Priority Code Point (PCP). The PCP is carried internally in the IFH field IFH.VSTAX.TAG.CL_PCP.
Drop Eligible Indicator (DEI). The DEI is carried internally in the IFH field IFH.VSTAX.TAG.CL_DEI.
VLAN Identifier (VID). The VID is carried internally in the IFH field IFH.VSTAX.TAG.CL_VID.
Tag Protocol Identifier (TPID) type, which holds information about the TPID of the tag used for
classification. The TPID type is carried internally in IFH field IFH.VSTAX.TAG.TAG_TYPE. Extended
information about the tag type is carried in IFH.DST.TAG_TPID.
The devices recognize five types of tags based on the TPID, which is the EtherType in front of the tag:
•
•
•
Customer tags (C-tags), which use TPID 0x8100.
Service tags (S-tags), which use TPID 0x88A8 (IEEE 802.1ad).
Custom service tags (S-tags), which use one of three custom TPIDs programmed in
ANA_CL::VLAN_STAG_CFG. Three different values are supported.
For customer tags and service tags, both VLAN tags (tags with nonzero VID) and priority tags (tags with
VID = 0) are processed.
It is configurable which of the five recognized TPIDs are valid for the VLAN classification
(VLAN_TPID_CTRL.BASIC_TPID_AWARE_DIS). Only VLAN tags with valid TPIDs are used by the
VLAN classification. The parsing of VLAN tags stops when a VLAN tag with an invalid TPID is seen.
The VLAN tag information is either retrieved from a tag in the incoming frame or from default port-based
configuration. The port-based VLAN tag information is configured in ANA_CL:PORT:VLAN_CTRL.
For double tagged frames (at least two VLAN tags with valid TPIDs), there is an option to use the inner
tag instead of the outer tag (VLAN_CTRL.VLAN_TAG_SEL). Note that if the frame has more than two
valid VLAN tags, the inner tag refers to the tag immediately after the outer tag.
The following illustration shows the flow chart for basic VLAN classification.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
108
Functional Descriptions
Figure 18 • Basic VLAN Classification Flow Chart
TAG_TPID = VLAN_CTRL.PORT_TAG_TYPE
PCP = VLAN_CTRL.PORT_PCP
DEI = VLAN_CTRL.PORT_DEI
VID = VLAN_CTRL.PORT_VID
A tag is valid for VLAN classification when:
- the TPID is one of 5 known TPIDs, and
- BASIC_TPID_AWARE_DIS[tag number, TPID] is cleared.
Frame has valid outer tag and
VLAN_AWARE_ENA[port]
Y
Frame has valid inner tag and
VLAN_TAG_SEL[port]
Y
TAG_TPID = TPID(Frame.InnerTPID)
PCP = Frame.InnerPCP
DEI = Frame.InnerDEI
VID = Frame.InnerVID
TAG_TPID = TPID(Frame.OuterTPID)
PCP = Frame.OuterPCP
DEI = Frame.OuterDEI
VID = Frame.OuterVID
VLAN_PCP_DEI_TRANS_ENA
Y
PCP = PCP_TRANS_VAL[port ][8 x DEI + PCP ]
DEI = DEI_TRANS_VAL[port][8 x DEI + PCP ]
VID == 0
Y
VID = VLAN_CTRL.PORT_VID
Basic Classified Tag information
In addition to the classification shown, the port decides the number of VLAN tags to pop at egress
(VLAN_CTRL.VLAN_POP_CNT). If the configured number of tags to pop is greater than the actual
number of valid tags in the frame, the number is reduced to the number of actual valid tags in the frame.
A maximum of three VLAN tags can be popped. The VLAN pop count is carried in IFH field
IFH.TAGGING.POP_CNT.
Finally, the VLAN classification sets IFH field IFH.VSTAX.TAG.WAS_TAGGED if the port is VLAN aware
and the frame has one or more valid VLAN tags. WAS_TAGGED is used the rewriter to make decision on
whether tag information from existing tags can be used for rewriting.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
109
Functional Descriptions
The basic classified tag information can be overwritten by more intelligent decisions made in the VCAP
CLM.
3.14.1.7
Link Aggregation Code Generation
This section provides information about the functions in link aggregation code generation.
The following table lists the registers associated with aggregation code generation.
Table 78 •
Aggregation Code Generation Registers
Register
Description
Replication
ANA_CL::AGGR_CFG
Configures use of Layer 2 through Layer 4 flow information for link
aggregation code generation.
Common
The classifier generates a link aggregation code, which is used in the analyzer when selecting to which
port in a link aggregation group a frame is forwarded.
The following contributions to the link aggregation code are configured in the AGGR_CFG register.
•
•
•
•
•
•
•
Destination MAC address—use the 48 bits of the DMAC.
Reversed destination MAC address—use the 48 bits of the DMAC in reverse order (bit 47 becomes
bit 0, bit 46 becomes bit 1, and so on).
Source MAC address—use the lower 48 bits of the SMAC.
IPv6 flow label—use the 20 bits of the flow label.
Source and destination IP addresses for IPv4 and IPv6 frames —use all bits of both the SIP and DIP.
TCP/UDP source and destination ports for IPv4 and IPv6 frames use the 16 bits of both the SPORT
and DPORT.
Random aggregation code—use a 4-bit pseudo-random number.
All contributions that are enabled are 4-bit XOR’ed, and the resulting code is used by the Layer 2
forwarding function (ANA_AC) to select 1 out of 16 link aggregation port masks. The 16 link aggregation
port masks are configured in ANA_AC:AGGR. For more information see Aggregation Group Port
Selection, page 186.
If AGGR_CFG.AGGR_USE_VSTAX_AC_ENA is enabled and the frame has a VStaX header, all other
contributions to link aggregation code calculation are ignored, and the AC field of the VStaX-header is
used directly. Otherwise, link aggregation code generation operates as previously described.
Note that AGGR_CFG.AGGR_DMAC_REVERSED_ENA and AGGR_CFG.AGGR_DMAC_ENA are
independent. If both bits are enabled, the frame’s DMAC contributes both normally and reversed in the
link aggregation code calculation.
3.14.1.8
CPU Forwarding Determination
The following table lists the registers associated with CPU forwarding in the basic classifier.
Table 79 •
CPU Forwarding Registers
Register
Description
Replication
ANA_CL:PORT:CAPTURE_CFG
Enables CPU forwarding for various frame types.
Configures valid TPIDs for CPU forwarding.
Per port
ANA_CL:PORT:CAPTURE_BPDU_CFG
Enables CPU forwarding per BPDU address
Per port
ANA_CL:PORT:CAPTURE_GXRP_CFG
Enables CPU forwarding per GxRP address
Per port
ANA_CL:PORT:CAPTURE_Y1731_AG_CFG
Enables CPU forwarding per Y.1731/IEEE802.1ag Per port
address
ANA_CL::CPU_PROTO_QU_CFG
CPU extraction queues for various frame types
None
ANA_CL::CPU_8021_QU_CFG
CPU extraction queues for BPDU, GARP, and
Y.1731/IEEE802.1ag addresses
None
ANA_CL::VRAP_CFG
VLAN configuration of VRAP filter
None
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
110
Functional Descriptions
Table 79 •
CPU Forwarding Registers (continued)
Register
Description
Replication
ANA_CL::VRAP_HDR_DATA
Data match against VRAP header
None
ANA_CL::VRAP_HDR_MASK
Mask used to don’t care bits in the VRAP header
None
The basic classifier has support for determining whether certain frames must be forwarded to the CPU
extraction queues. Other parts of the VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02
devices can also determine CPU forwarding, for example, the VCAPs or the VOEs. All events leading to
CPU forwarding are OR’ed together, and the final CPU extraction queue mask, which is available to the
user, contains the sum of all events leading to CPU extraction.
Upon CPU forwarding by the basic classifier, the frame type and configuration determine whether the
frame is redirected or copied to the CPU. Any frame type or event causing a redirection to the CPU
causes all front ports to be removed from the forwarding decision—only the CPU receives the frame.
When copying a frame to the CPU, the normal forwarding of the frame to front ports is unaffected.
The following table lists the standard frame types recognized by the basic classifier, with respect to CPU
forwarding.
Table 80 •
Frame Type Definitions for CPU Forwarding
Frame
Condition
Copy/Redirect
BPDU Reserved Addresses
(IEEE 802.1D 7.12.6)
DMAC = 0x0180C2000000 to 0x0180C20000F
Redirect/Copy/Discard
GARP Application Addresses
(IEEE 802.1D 12.5)
DMAC = 0x0180C2000020 to 0x0180C200002F
Redirect/Copy/Discard
Y.1731/IEEE802.1ag Addresses
DMAC = 0x0180C2000030 to 0x0180C200003F
Redirect/Copy/Discard
IGMP
DMAC = 0x01005E000000 to 0x01005E7FFFFF
EtherType = IPv4
IP Protocol = IGMP
Redirect
MLD
DMAC = 0x333300000000 to 0x3333FFFFFFFFF
EtherType = IPv6
IPv6 Next Header = 0 (Hop-by-hop options header)
Hop-by-hop options header with the first option being a
Router Alert option with the MLD message (Option Type
= 5, Opt Data Len = 2, Option Data = 0).
Redirect
Hop-by-hop
EtherType = IPv6
IPv6 Next Header = 0 (Hop-by-hop options header)
Redirect
ICMPv6
EtherType = IPv6
IPv6 Next Header = 58 (ICMPv6)
Redirect
IPv4 Multicast Ctrl
DMAC = 0x01005E000000 to 0x01005E7FFFFF
EtherType = IPv4
IP protocol is not IGMP
IPv4 DIP inside 224.0.0.x
Copy
IPv6 Multicast Ctrl
DMAC = 0x333300000000 to 0x3333FFFFFFFF
EtherType = IPv6
IPv6 header is not hop-by-hop or ICMPv6
IPv6 DIP inside FF02::/16
Copy
Each frame type has a corresponding CPU extraction queue. Note that hop-by-hop and ICMPv6 frames
share the same CPU extraction queue.
Prior to deciding whether to CPU forward a frame, the frame’s VLAN tagging must comply with a
configurable filter (ANA_CL::CAPTURE_CFG.CAPTURE_TPID_AWARE_DIS). For all frame types listed
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
111
Functional Descriptions
in Table 80, page 111, only untagged frames or VLAN-tagged frames where the outer VLAN tag’s TPID is
not disabled are considered.
The basic classifier can recognize VRAP frames and redirect them to the CPU. This is a proprietary
frame format, which is used for reading and writing switch configuration registers through Ethernet
frames. For more information, see VRAP Engine, page 289.
The VRAP filter in the classifier performs three checks in order to determine whether a frame is a VRAP
frame:
1.
2.
3.
VLAN check. The filter can be either VLAN unaware or VLAN aware
(ANA_CL::VRAP_CFG.VRAP_VLAN_AWARE_ENA). If VLAN unaware, VRAP frames must be
untagged. If VLAN aware, VRAP frames must be VLAN tagged and the frame’s VID must match a
configured value (ANA_CL::VRAP_CFG.VRAP_VID). Double VLAN tagged frames always fail this
check.
EtherType and EPID check. The EtherType must be 0x8880 and the EPID (bytes 0 and 1 after the
EtherType) must be 0x0004.
VRAP header check. The VRAP header (bytes 0, 1, 2, and 3 after the EPID) must match a 32-bit
configured value (ANA_CL::VRAP_HDR_DATA) where any bits can be don’t cared by a mask
(ANA_CL::VRAP_HDR_MASK).
If all three checks are fulfilled, frames are redirected to CPU extraction queue
ANA_CL::CPU_PROTO_QU_CFG.CPU_VRAP_QU. The VRAP filter is enabled in
ANA_CL:PORT:CAPTURE_CFG.CPU_VRAP_REDIR_ENA.
3.14.1.9
Logical Port Mapping
The basic classifier works on the physical port number given by the interface where the frame was
received. Other device blocks work on a logical port number that defines the link aggregation instance
rather than the physical port. The logical port number is defined in
ANA_CL:PORT:PORT_ID_CFG.LPORT_NUM. It is, for instance, used for learning and forwarding in
ANA_L2.
3.14.2
VCAP CLM Processing
Each frame is matched six times against entries in the VCAP CLM. The matching is done in serial
implying results from one match can influence the keys used in the next match.
The VCAP CLM returns an action for each enabled VCAP CLM lookup. If the lookup matches an entry in
VCAP CLM, the associated action is returned. If an entry is not matched, a per-port default action is
returned. There is no difference between an action from a match and a default action.
3.14.2.1
VCAP CLM Port Configuration and Key Selection
This section provides information about special port configurations that control the key generation for
VCAP CLM.
The following table lists the registers associated with port configuration for VCAP CLM.
Table 81 •
Port Configuration of VCAP CLM
Register
Description
Replication
ANA_CL:PORT:ADV_CL_CFG
Configuration of the key selection for the VCAP CLM.
Enables VCAP CLM lookups.
Per port per lookup
ANA_CL::CLM_MISC_CTRL
Force lookup in VCAP CLM for looped frames or frames
where processing is terminated by a pipeline point.
None
VCAP CLM is looked up if the lookup is enabled by the port configuration
(ADV_CL_CFG.LOOKUP_ENA) or if the previous VCAP CLM lookup has returned a key type for the next
lookup through VCAP CLM action NXT_KEY_TYPE. However, if the previous lookup returns
NXT_KEY_TYPE = CLMS_DONE, then no further lookups are done, even if the port has enabled the
lookup.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
112
Functional Descriptions
Prior to each VCAP CLM lookup, the type of key to be used in the lookup is selected. A number of
parameters control the key type selection:
•
•
Configuration parameters (ADV_CL_CFG).
For each (port, VCAP CLM lookup) a key type can be specified for different frame types. Although
any key type can be specified for a given frame type, not all key types are in reality applicable to a
given frame type. The applicable key types are listed in the ANA_CL:PORT:ADV_CL_CFG register
description. The following frame types are supported:
•
IPv6 frames (EtherType 0x86DD and IP version 6)
•
IPv4 frames (EtherType 0x0800 and IP version 4)
•
MPLS unicast frames (EtherType 0x8847)
•
MPLS multicast frames (EtherType 0x8848)
•
MPLS label stack processing (frame type after MPLS link layer is processed)
•
Other frames (non-MPLS, non-IP)
The type of the current protocol layer.
For each VCAP CLM lookup, a frame pointer can optionally be moved to the next protocol layer, and
the type of the next protocol layer can be specified. This influences key type selection for the next
VCAP CLM lookup. The variables frame_ptr and frame_type holds information about the current
protocol layer. For more information about how frame_ptr and frame_type is updated after each
VCAP CLM lookup, see Frame Pointer and Frame Type Update, page 115.
Key type specified in action in previous VCAP CLM lookup.
The action of a VCAP CLM lookup can optionally specify a specific key type to be used in the following
VCAP CLM lookup.
The full algorithm used for selecting VCAP CLM key type is shown in the following pseudo code.
// ======================================================================
// ANA_CL: VCAP CLM Key Type Selection
//
// Determine which key type to use in VCAP CLM lookup.
// The algorithm is run prior to each VCAP CLM lookup.
// ---------------------------------------------------------------------// Frame position (byte pointer) for use as base for next VCAP CLM key
// Updated by UpdateFramePtrAndType() upon VCAP CLM lookup
int frame_ptr = 0;
// Frame type at frame_ptr position.
// Updated by UpdateFramePtrAndType() upon VCAP CLM lookup
//
// Supported values:
//
ETH: frame_ptr points to DMAC
//
CW:
frame_ptr points to start of IP header or CW/ACH of MPLS frame
//
MPLS: frame_ptr points to an MPLS label.
frame_type_t frame_type = ETH;
int ClmKeyType(
// VCAP CLM index. 0=First VCAP CLM lookup, 5=Last lookup
clm_idx,
// Action from previous VCAP CLM lookup (if clm_idx > 0)
//
// clm_action.vld is only set if VCAP CLM lookup
// was enabled.
clm_action,
)
{
int
key_type = 0;
port_cfg_t port_clm_cfg;
port_clm_cfg = csr.port[port_num].adv_cl_cfg[clm_idx];
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
113
Functional Descriptions
if (clm_action.vld && clm_action.nxt_key_type != 0) {
// Previous VCAP CLM lookup specifies next key type
return clm_action.nxt_key_type;
}
// Determine key type based on port parameters and frame_ptr/frame_type
switch (frame_type) {
case ETH:
// Choose key type based on EtherType
// The EtherType() function skips any VLAN tags. A maximum of 3 VLAN
// tags can be skipped.
switch (EtherType(frame_ptr)) {
case ETYPE_IP4: // 0x0800
key_type = port_clm_cfg.ip4_clm_key_sel;
break;
case ETYPE_IP6: // 0x86DD
key_type = port_clm_cfg.ip6_clm_key_sel;
break;
case ETYPE_MPLS_UC: // 0x8847
key_type = port_clm_cfg.mpls_uc_clm_key_sel;
break;
case ETYPE_MPLS_MC: // 0x8848
key_type = port_clm_cfg.mpls_mc_clm_key_sel;
break;
}
if (key_type = 0) {
key_type = port_clm_cfg.etype_clm_key_sel;
}
break;
case CW:
switch (IPVersion(frame_ptr)) {
case 4 : key_type = port_clm_cfg.ip4_clm_key_sel;
break;
case 6 : key_type = port_clm_cfg.ip6_clm_key_sel;
break;
default: key_type = port_clm_cfg.etype_clm_key_sel; break;
}
break;
case MPLS:
key_type = port_clm_cfg.mlbs_clm_key_sel;
break;
}
return key_type;
} // ClmKeyType
// --------------------------------------------------------------------// ANA_CL: VCAP CLM Key Type Selection
// ======================================================================
By default, frames looped by the rewriter or frames already discarded or CPU-redirected, for instance the
basic classifier, are not subject to VCAP CLM lookups. Optionally, VCAP CLM lookups can be enforced
through configuration ANA_CL::CLM_MISC_CTRL.LBK_CLM_FORCE_ENA for looped frames and
through ANA_CL::CLM_MISC_CTRL.IGR_PORT_CLM_FORCE_ENA for frames already discarded or
CPU-redirected. When forcing a VCAP CLM lookup, the VCAP CLM key is chosen from the configuration
in ANA_CL::CLM_MISC_CTRL.FORCED_KEY_SEL. Only selected keys are available.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
114
Functional Descriptions
3.14.2.2
Frame Pointer and Frame Type Update
After each VCAP CLM lookup, the information in the associated action is used to update frame_ptr and
frame_type. This in turn influences the key type and key field values used for the next VCAP CLM
lookup.
The following fields in the VCAP CLM action can be used to move to the next protocol layer:
•
NXT_OFFSET_FROM_TYPE.
Move frame pointer past current protocol layer (Ethernet and/or IP). The actual number of bytes the
frame pointer is moved may vary depending on content of the current protocol layer, such as the
number of VLAN tags or IPv4 options.
NXT_NORM_W16_OFFSET.
Move frame pointer a number of 16 bit words. If both NXT_OFFSET_FROM_TYPE and
NXT_NORM_W16_OFFSET are specified, then frame pointer is first moved based on
NXT_OFFSET_FROM_TYPE and afterwards moved further into the frame based on
NXT_NORM_W16_OFFSET.
NXT_TYPE_AFTER_OFFSET.
Specify protocol layer at new frame pointer position.
•
•
For more information about VCAP CLM action fields, see Table 72, page 94.
Each VCAP CLM lookup can at most move the frame pointer 66 bytes. The following pseudo code shows
the algorithm used to update frame_ptr and frame_type upon each VCPA_CLM lookup.
//
//
//
//
//
//
//
//
======================================================================
ANA_CL: VCAP CLM Frame Pointer and Frame Type Update
Update frame_ptr and frame_type upon VCAP CLM lookup.
Prior to first VCAP CLM lookup frame_ptr is initialized to 0 and
frame_type is set to ETH.
The algorithm is run after each VCAP CLM lookup.
----------------------------------------------------------------------
// Function for updating
//
frame_ptr
//
frame_type
// based on action from VCAP CLM lookup
void UpdateFramePtrAndType(
// VCAP CLM index. 0=First VCAP CLM lookup,
// 5=Last VCAP CLM lookup
clm_idx,
// Action from VCAP CLM lookup
// clm_action.vld is only set if
// VCAP CLM lookup was enabled.
clm_action,
// From ClmKeyFieldsMpls()
clm_key_fields_mpls,
)
{
int frame_ptr_current = frame_ptr;
int frame_type_current = frame_type;
if (!clm_action.vld) return;
if (clm_action.nxt_offset_from_type > 0) {
// Move frame_ptr based on frame type
switch (clm_action.nxt_offset_from_type) {
case SKIP_ETH:
if (frame_type_current == ETH) {
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
115
Functional Descriptions
// Move frame_ptr past DMAC, SMAC, 0-3 VLAN tags and EtherType
SkipLinkLayer(&frame_ptr);
}
break;
case SKIP_IP_ETH:
switch (frame_type_current) {
case ETH:
// Move frame_ptr past DMAC, SMAC, 0-3 VLAN tags and EtherType
if (EtherType(frame_ptr) == ETYPE_IP4) || // 0x0800
(EtherType(frame_ptr) == ETYPE_IP6) { // 0x86DD
SkipLinkLayer(&frame_ptr);
// Move frame_ptr past IPv4 header (including options) or
// IPv6 header
SkipIPHeader(&frame_ptr);
}
break;
case CW:
switch (IPVersion(frame_ptr)) {
case 4:
case 6:
// Move frame_ptr past IPv4 header (including options) or
// IPv6 header
SkipIPHeader(&frame_ptr);
break;
}
break;
}
}
frame_type = clm_action.nxt_type_after_offset;
} // clm_action.nxt_offset_from_type > 0
if (clm_action.nxt_norm_w16_offset > 0) {
// Move frame_ptr a specific number of bytes
frame_ptr = frame_ptr + 2*clm_action.nxt_norm_w16_offset;
frame_type = clm_action.nxt_type_after_offset;
}
if (frame_type_current == DATA &&
clm_action.nxt_key_type != 0) {
// Allow frame_type change, regardsless of whether frame_ptr
// has been moved
frame_type = clm_action.nxt_type_after_offset;
}
// PW termination of MPLS frame
if (clm_action.fwd_type == TERMINATE_PW) {
if IsOam(frame_ptr, csr) && (clm_key_fields_mpls.rsv_lbl_pos) {
// Reserved label used to identify OAM
// Move frame_ptr if reserved MPLS label was skipped by
// ClmKeyFieldsMpls() in key generation prior to VCAP CLM lookup
frame_ptr += 4;
} elsif (frame_type == CW && !IsOam(frame_ptr, csr)) {
// PW termination of MPLS frame with CW => Skip CW and
// change frame_type
frame_ptr += 4;
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
116
Functional Descriptions
frame_type = ETH;
}
}
// OAM LSP
if (clm_action.fwd_type == POP_LBL && IsOam(frame_ptr, csr) &&
(clm_key_fields_mpls.rsv_lbl_pos)) {
// Reserved label used to identify OAM
// Move frame_ptr if reserved MPLS label was skipped by
// ClmKeyFieldsMpls() in key generation prior to VCAP CLM lookup
frame_ptr += 4;
}
if (frame_ptr - frame_ptr_current > 66) {
// Cannot skip >66 bytes per VCAP CLM.
// Set sticky bit and don't skip anything
csr.adv_cl_max_w16_offset_fail_sticky = 1;
frame_ptr = frame_ptr_current;
frame_type = frame_type_current;
}
if (frame_ptr > 126 ) {
// Cannot skip >126 bytes total.
// Set sticky bit and discard frame
csr.adv_cl_nxt_offset_too_big_sticky = 1;
frame.abort = true;
}
} // UpdateFramePtrAndType
// ---------------------------------------------------------------------// ANA_CL: VCAP CLM Frame Pointer and Frame Type Update
// ======================================================================
3.14.2.3
Removing Protocol Layers
The analyzer classifier can instruct the rewriter to remove protocol layers from the frame, that is, to
remove a number of bytes from the start of the frame.
This is achieved by setting the NXT_NORMALIZE action field in the VCAP CLM action. When
NXT_NORMALIZE is set in a VCAP CLM action, then the frame pointer for the next VCAP CLM lookup
(if any) is calculated, and the rewriter is then instructed to remove all bytes up to, but not including, the
position pointed to by the frame pointer. For more information about the calculation, see Frame Pointer
and Frame Type Update, page 115.
If multiple VCAP CLM actions have the NXT_NORMALIZE bit set, the last such action controls the
number of bytes removed by the rewriter.
Note that the rewriter can skip a maximum of 42 bytes, starting at the DMAC of the frame. This
corresponds to an Ethernet header with three VLAN tags and an MPLS stack with three LSEs and a
control word (CW).
3.14.2.4
Miscellaneous VCAP CLM Key Configuration
The analyzer classifier can control some specific fields when generating the VCAP CLM keys. The
following table lists the registers that control the parameters.
Table 82 •
Register
Miscellaneous VCAP CLM Key Configuration
Description
ANA_CL:PORT:ADV_CL_CFG Configures L3_DSCP and TCI0 source.
Replication
Per port per VCAP
CLM lookup
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
117
Functional Descriptions
Table 82 •
Miscellaneous VCAP CLM Key Configuration (continued)
Register
Description
Replication
ANA_CL::CLM_MISC_CTRL
Configures IGR_PORT_MASK_SEL and IGR_PORT_MASK.
None
Each port can control specific fields in the generated keys:
•
•
Selects source of DSCP in L3_DSCP key field
(ANA_CL:PORT:ADV_CL_CFG.USE_CL_DSCP_ENA). By default, the DSCP value is taken from
the frame. Another option is to use the current classified DSCP value as input to the key. The current
classified DSCP value is the result from either the previous VCAM_CLM lookup or the basic
classifier if this is the first lookup.
Selects source of VID, PCP, and DEI in the VID0, PCP0, and DEI0 key fields
(ANA_CL:PORT:ADV_CL_CFG.USE_CL_TCI0_ENA). By default, the values are taken from the
outer VLAN tag in the frame (or port’s VLAN if frame is untagged). Another option is to use the
current classified values as input to the key. The current classified values are the result from either
the previous VCAM_CLM lookup or the basic classifier if this is the first lookup.
Note that these configurations are only applicable to keys containing the relevant key fields.
VCAP CLM keys NORMAL, NORMAL_7TUPLE, and NORMAL_5TUPLE_IP4 contain the key fields
IGR_PORT_MASK_SEL and IGR_PORT_MASK. For frames received on a front port,
IGR_PORT_MASK_SEL is set to 0 and the bit corresponding to the frame’s physical ingress port number
is set in IGR_PORT_MASK. The following lists some settings for frames received on other interfaces and
how this can be configured through register CLM_MISC_CTRL:
•
•
•
•
•
Loopback frames:
By default, IGR_PORT_MASK_SEL=1 and IGR_PORT_MASK has one bit set corresponding to the
physical port which the frame was looped on. Optionally use IGR_PORT_MASK_SEL = 3.
Masqueraded frames:
By default, IGR_PORT_MASK_SEL=0 and IGR_PORT_MASK has one bit set corresponding to the
masquerade port. Optionally, use IGR_PORT_MASK_SEL = 2.
VStaX frames:
By default, frames received with a VStaX header on a front port use IGR_PORT_MASK_SEL = 0.
Optionally, use IGR_PORT_MASK_SEL = 3.
Virtual device frames:
By default, IGR_PORT_MASK_SEL = 0 and IGR_PORT_MASK has one bit set corresponding to
the original physical ingress port. Optionally, use IGR_PORT_MASK_SEL = 3.
CPU injected frames:
By default, IGR_PORT_MASK_SEL=0 and IGR_PORT_MASK has none bits set. Optionally use
IGR_PORT_MASK_SEL=3.
For more information about the contents of IGR_PORT_MASK_SEL and IGR_PORT_MASK, see VCAP
CLM Keys and Actions, page 73.
3.14.2.5
VCAP CLM Range Checkers
The following table lists the registers associated with configuring VCAP CLM range checkers.
Table 83 •
VCAP CLM Range Checker Configuration Registers Overview
Register
Description
Replication
ANA_CL::ADV_RNG_CTRL
Configures range checker types
Per range checker
ANA_CL::ADV_RNG_VALUE_CFG Configures range start and end points
Per range checker
Eight global VCAP CLM range checkers are supported by the NORMAL, NORMAL_7TUPLE,
NORMAL_5TUPLE_IP4, and PURE_5TUPLE_IP4 keys. All frames using these keys are compared
against the range checkers and a 1-bit range “match/no match” flag is returned for each range checker.
The combined eight match/no match flags are used in the L4_RNG key field. So, it is possible to include
for example ranges of DSCP values and/or ranges of TCP source port numbers in the VCAP rules.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
118
Functional Descriptions
Note: VCAP IS2 also supports range checkers, however, they are independent of the VCAP CLM range
checkers.
The range key is generated for each frame based on extracted frame data and the configuration in
ANA_CL::ADV_RNG_CTRL. Each of the eight range checkers can be configured to one of the following
range types:
•
•
•
•
•
•
TCP/UDP destination port range
Input to the range is the frame’s TCP/UDP destination port number.
Range is only applicable to TCP/UDP frames.
TCP/UDP source port range
Input to the range is the frame’s TCP/UDP source port number.
Range is only applicable to TCP/UDP frames.
TCP/UDP source and destination ports range. Range is matched if either source or destination port
is within range.
Input to the range are the frame’s TCP/UDP source and destination port numbers.
Range is only applicable to TCP/UDP frames.
VID range
Input to the range is the classified VID.
Range is applicable to all frames.
DSCP range
Input to the range is the classified DSCP value.
Range is applicable to IPv4 and IPv6 frames.
EtherType range
Input to the range is the frame’s EtherType.
Range is applicable to all frames.
Range start points and range end points are configured in ANA_CL::ADV_RNG_VALUE_CFG with both
the start point and the end point being included in the range. A range matches if the input value to the
range (for instance the frame’s TCP/UDP destination port) is within the range defined by the start point
and the end point.
3.14.2.6
Cascading VCAP CLM Lookups
Each of the six VCAP CLM lookups can be “cascaded” such that a frame only matches a VCAP CLM
entry in lookup n+1 if it also matched a specific entry in VCAP CLM lookup n. In other words, VCAP CLM
entries in different VCAP CLM lookups are bound together.
The following parameters control cascading of VCAP CLM entries:
•
•
Key field: G_IDX
The generic index, G_IDX, is available in most VCAP CLM key types. The value of this field can be
specified in the action of the preceding VCAP CLM lookup.
Action fields: NXT_IDX_CTRL and NXT_IDX
Controls how to calculate G_IDX for next VCAP CLM lookup.
For information about detailed encoding of NXT_IDX_CTRL, see Table 72, page 94.
In addition to cascading VCAP CLM lookups, it is also possible for each VCAP CLM lookup to move to
the next protocol layer of the frame, such that key values for lookup n + 1 are retrieved from a different
offset in the frame than for lookup n. For information about the algorithm, see Frame Pointer and Frame
Type Update, page 115.
3.14.3
QoS Mapping Table
The following table lists the registers associated with the QoS mapping table.
Table 84 •
VCAP CLM QoS Mapping Table Registers Overview
Register
Description
Replication
ANA_CL:MAP_TBL:SET_CTRL
Controls which mapping results to use.
512
ANA_CL:MAP_TBL:MAP_ENTRY
Configuration of the QoS mapping values.
4,096
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
119
Functional Descriptions
The classifier contains a shared QoS mapping table with 4,096 entries
(ANA_CL:MAP_TBL:MAP_ENTRY) that maps incoming QoS information to classified internal QoS
information. Inputs to a mapping can be either DEI and PCP from VLAN tags, DSCP value, or MPLS TC
bits. Outputs from a mapping are new classified values for COSID, DEI, PCP, DSCP, QoS class, DP
level, and TC bits. The table is looked up twice for each frame with two different keys.
The QoS mapping table is laid out with 512 rows with each eight mapping entries. Each specific QoS
mapping only uses a subset of the 4,096 entries and it therefore allows for many QoS different mappings
at the same time. It can for instance hold 64 unique mappings from DSCP to DEI/PCP or 256 unique
translations of DEI/PCP to DEI/PCP.
The two lookups per frame in the QoS mapping table are defined by the VCAP CLM actions MAP_IDX
and MAP_KEY. One VCAP CLM match can only define one set MAP_IDX and MAP_KEY so two lookups
in the QoS mapping table requires two VCAP CLM matches. Action MAP_IDX defines which one of the
512 rows the QoS mapping starts at and the MAP_KEY defines which parameter from the frame to use
as key into the QoS mapping table. The following lists the available keys and how the resulting row and
entry number in the mapping table is derived:
•
PCP. Use PCP from the frame’s outer VLAN tag. If the frame is untagged, the port’s VLAN tag is
used. Row and entry number is derived the following way:
Row = MAP_IDX,
Entry = PCP.
•
Number of entries per mapping: 8 entries.
DEI and PCP. Use DEI and PCP from one of the frame’s VLAN tags. The MAP_KEY can select
between using either outer, middle, or inner tag. If the frame is untagged, the port’s VLAN tag is
used. Row and entry number is derived the following way:
Row = (8x DEI + PCP) DIV 8 + MAP_IDX,
Entry = (8x DEI + PCP) MOD 8.
•
Number of entries per mapping: 16 entries.
DSCP (IP frames only). Use the frame’s DSCP value. For non-IP frames, no mapping is done. Row
and entry number is derived the following way:
Row = DSCP DIV 8 + MAP_IDX,
Entry = DSCP MOD 8.
•
Number of entries per mapping: 64 entries.
DSCP (all frames). Use the frame’s DSCP value. For non-IP VLAN tagged frames, use DEI and
PCP from the frame’s outer VLAN tag. For non-IP untagged frames, use DEI and PCP from port
VLAN. Row and entry number is derived the following way:
IP frames:
Row = DSCP DIV 8 + MAP_IDX,
Entry = DSCP MOD 8.
Non-IP frames:
Row = (8x DEI + PCP) DIV 8 + MAP_IDX + 8,
Entry = (8x DEI + PCP) MOD 8.
•
Number of entries per mapping: 80 entries.
TC. Use the frame’s classified TC bits from the extracted MPLS label (label selected by VCAP CLM
actions TC_ENA or TC_LABEL). Row and entry number is derived the following way:
Row = MAP_IDX,
Entry = TC.
Number of entries per mapping: 8 entries.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
120
Functional Descriptions
QoS mappings can be shared between multiple VCAP CLM entries by defining the same mapping and
using the same entries in the mapping table. It is up to the user of the QoS mapping table to make sure
that entries are allocated so that they do not overlap unintentionally.
Each entry in the QoS mapping table (ANA_CL:MAP_TBL:MAP_ENTRY) contains a full set of new QoS
values (COSID, DEI, PCP, QoS class, DP level, DSCP, TC) to be used as new classified values instead
of the current classified values from basic classification and VCAP CLM. Each of the QoS values is gated
by an enable bit (ANA_CL:MAP_TBL:SET_CTRL) so that a mapping can for example define a complete
new set of QoS values by enabling all values or it can override selected values only. Note that
ANA_CL:MAP_TBL:SET_CTRL must be configured for each used row in the mapping table.
The following illustration shows an example of a frame for which a DSCP and a DEI/PCP mapping are
defined.
Figure 19 • Example of QoS Mappings
Frame
DMAC
SMAC
VLAN
tag0
VLAN
tag1
VLAN
tag2
Ty
pe
IPv4 header
Mapping 0:
VCAP CLM action MAP_KEY = 0
VCAP CLM action MAP_IDX = 8
Frame.DEI = 1
Frame.PCP = 3)
FCS
Mapping 1:
VCAP CLM action MAP_KEY = 6
VCAP CLM action MAP_IDX = 128
Frame.DSCP = 26
ANA_CL:MAP_TBL
Entry: 7
Entry: 0
Row: 0
MAP_IDX
9
MAP_IDX
DEI=0
PCP=0
8
DEI=1
PCP=7
DEI=1
PCP=3
QOS_VAL = 3
DP_VAL = 1
PCP_VAL = 5
DEI_VAL = 1
128
DSCP=0
DSCP=26
DSCP_VAL = 45
135
DSCP=63
Row: 511
3.14.4
Analyzer Classifier Diagnostics
The analyzer classifier contains a large set of sticky bits that can inform about the frame processing and
decisions made by ANA_CL. The following categories of sticky bits are available.
•
•
•
•
•
Frame acceptance filtering (ANA_CL::FILTER_STICKY, ANA_CL::VLAN_FILTER_STICKY).
VLAN and QoS classification (ANA_CL::CLASS_STICKY)
CPU forwarding (ANA_CL::CAT_STICKY)
VCAP CLM lookups and actions, QoS mapping tables (ANA_CL::ADV_CL_STICKY)
IP header checks (ANA_CL::IP_HDR_CHK_STICKY)
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
121
Functional Descriptions
The sticky bits are common for all ports in the analyzer classifier. All sticky bits, except for VCAP CLM
sticky bits, have four corresponding sticky mask bits (ANA_CL:STICKY_MASK) that allow any sticky bit
to be counted by one of the four per-port analyzer access control counters. For more information, see
Analyzer Statistics, page 197.
3.15
VLAN and MSTP
The VLAN table and the MSTP table are the two main tables that control VLAN and Spanning Tree frame
processing.
The following table shows the configuration parameters (located within the ANA_L3 configuration target)
for each entry in the VLAN table.
Table 85 •
VLAN Table (5120 Entries)
Field in ANA_L3:VLAN Bits Description
VMID
7
VMID, identifying VLAN’s router leg.
VLAN_MSTP_PTR
7
Pointer to STP instance associated with VLAN.
VLAN_FID
13
FID to use for learning and forwarding.
VLAN_SEC_FWD_ENA 1
Enables secure forwarding on a per VLAN basis.
When secure forwarding is enabled, only frames with known SMAC are forwarded.
VLAN_FLOOD_DIS
1
Disables flooding of frames with unknown DMAC on a per VLAN basis.
VLAN_LRN_DIS
1
Disables learning of SMAC of frames received on this VLAN.
VLAN_RLEG_ENA
1
Enables router leg in VLAN.
VLAN_PRIVATE_ENA
1
Enables/disables this VLAN as a Private VLAN (PVLAN).
VLAN_MIRROR_ENA
1
VLAN mirror enable flag. If this field is set, frames classified to this ingress VLAN are
mirrored.
Note that a mirroring probe must also be configured to enable VLAN based mirroring.
see Mirroring, page 205.
VLAN_PORT_MASK
VLAN_PORT_MASK1
53
Specifies mask of ports belonging to VLAN.
TUPE_CTRL
16
Controls value for Table Update Engine (TUPE).
The following table shows the configuration parameters for each entry in the MSTP table.
Table 86 •
MSTP Table (66 Entries)
Field in ANA_L3:MSTP
Bits
Description
MSTP_FWD_MASK
1 per port
Enables/disables forwarding per port
MSTP_LRN_MASK
1 per port
Enables/disables learning per port
The following table lists common parameters that also affect the VLAN and MSTP processing of frames.
Table 87 •
Common VLAN and MSTP Parameters
Register/Field in ANA_L3_COMMON
Bits
Description
VLAN_CTRL.VLAN_ENA
1
Enables/disables VLAN lookup
PORT_FWD_CTRL
1 per port
Configures forwarding state per port
PORT_LRN_CTRL
1 per port
Configures learning state per port
VLAN_FILTER_CTRL
1 per port
Configures VLAN ingress filtering per port
VLAN_ISOLATED_CFG
1 per port
Configures isolated port mask
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
122
Functional Descriptions
Table 87 •
Common VLAN and MSTP Parameters (continued)
Register/Field in ANA_L3_COMMON
Bits
Description
VLAN_COMMUNITY_CFG
1 per port
Configures community port mask
If VLAN support is enabled (in VLAN_CTRL.VLAN_ENA), the classified VID is used to look up the VLAN
information in the VLAN table. The VLAN table in turn provides an address (VLAN_MSTP_PTR) into the
MSTP table. Learn, mirror, and forwarding results are calculated by combining information from the
VLAN and MSTP tables.
3.15.1
Private VLAN
In a Private VLAN (PVLAN), ports are configured to be one of three different types: Promiscuous,
isolated, or community.
Promiscuous Ports A promiscuous port can communicate with all ports in the PVLAN, including the
isolated and community ports.
Isolated Ports An isolated port has complete Layer 2 separation from the other ports within the same
PVLAN, but not from the promiscuous ports. PVLANs block all traffic to isolated ports except traffic from
promiscuous ports. Traffic from isolated port is forwarded only to promiscuous ports.
Community Ports Community ports communicate among themselves and with the PVLAN’s
promiscuous ports. Community ports cannot communicate with isolated ports.
PVLAN can be enabled per VLAN, and port type can be configured per physical port.
3.15.2
VLAN Pseudo Code
The pseudo code for the ingress VLAN processing is shown below. For routed frames, an egress VLAN
processing also takes place. This is not part of the following pseudo code.
In the pseudo code, “csr.” is used to denote configuration parameters, “req.” is used to denote input from
previous processing steps in the Analyzer, as well as information provided for the following steps in the
Analyzer.
if (req.cpu_inject != 0) {
// cpu_inject => Bypass!
return;
}
if (csr.vlan_ena) {
// Get VLAN entry based on Classified VID
igr_vlan_entry = csr.vlan_tbl[req.ivid + req.vsi_ena*4096];
} else {
// Default VLAN entry
igr_vlan_entry.vlan_mstp_ptr
= 0;
igr_vlan_entry.vlan_fid
= 0;
igr_vlan_entry.vlan_sec_fwd_ena = 0;
igr_vlan_entry.vlan_flood_dis
= 0;
igr_vlan_entry.vlan_lrn_dis
= 0;
igr_vlan_entry.vlan_rleg_ena
= 0;
igr_vlan_entry.vlan_private_ena = 0;
igr_vlan_entry.vlan_mirror_ena = 0;
igr_vlan_entry.vlan_port_mask
= -1; // All-ones
igr_vlan_entry.vmid
= 0;
}
// Retrieve MSTP state
if (csr.vlan_ena) {
igr_mstp_entry = csr.mstp_tbl[igr_vlan_entry.vlan_mstp_ptr];
} else {
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
123
Functional Descriptions
igr_mstp_entry.mstp_fwd_mask = -1; // All-ones
igr_mstp_entry.mstp_lrn_mask = -1; // All-ones
}
if (IsCpuPort(req.port_num) ||
IsVD0(req.port_num) ||
IsVD1(req.port_num)) {
// Received from CPU or VD0/VD1 =>
// * Do not learn
// * Do not perform ingress filtering
//
(these ports are not in ingress masks)
req.l2_lrn = 0;
} else {
// ---------------------------------------------// Perform ingress filtering and learning disable
// ---------------------------------------------// Port forwarding state
if (csr.common.port_fwd_ena[req.port_num] == 0) {
// Ingress port not enabled for forwarding
req.l2_fwd = 0;
csr.port_fwd_deny_sticky =1;
}
// Port learning state
if (csr.port_lrn_ena[req.port_num] == 0) {
req.l2_lrn = 0;
csr.port_lrn_deny_sticky = 1;
}
if (csr.vlan_ena) {
// Empty VLAN?
if (igr_vlan_entry.vlan_port_mask == 0) {
csr.vlan_lookup_invld_sticky = 1;
}
// VLAN ingress filtering
if (csr.vlan_igr_filter_ena[req.port_num] &&
igr_vlan_entry.vlan_port_mask[req.port_num] == 0) {
req.l2_fwd = 0;
req.l2_lrn = 0;
csr.vlan_igr_filter_sticky = 1;
} else {
// MSTP forwarding state
if (igr_mstp_entry.mstp_fwd_mask[req.port_num] == 0) {
req.l2_fwd = 0;
csr.mstp_discard_sticky = 1;
} else {
csr.mstp_fwd_allowed_sticky = 1;
}
// Learning enabled for VLAN?
if (igr_vlan_entry.vlan_lrn_dis) {
req.l2_lrn = 0;
csr.vlan_lrn_deny_sticky = 1;
// MSTP learning state
} else if (igr_mstp_entry.mstp_lrn_mask[req.port_num] == 0) {
req.l2_lrn = 0;
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
124
Functional Descriptions
csr.mstp_lrn_deny_sticky = 1;
} else {
csr.mstp_lrn_allowed_sticky = 1;
}
// Private VLAN handling
if (igr_vlan_entry.vlan_private_ena) {
if (req.vs2_avail == 0) {
// Not received from stack port, so determine port type and
// update req accordingly.
// 0b00: Promiscuous port
// 0b01: Community port
// 0b10: Isolated port
req.ingr_port_type = 0b00;
if (csr.vlan_community_mask[req.port_num]) {
req.ingr_port_type = 0b01;
}
if (csr.vlan_isolated_mask[req.port_num]) {
req.ingr_port_type = 0b10;
}
}
if (req.ingr_port_type == 0b10) {
// Isolated port
// Only allow communication with promiscuous ports
igr_vlan_entry.vlan_port_mask &=
(~csr.vlan_isolated_mask & ~csr.vlan_community_mask);
} else if (req.ingr_port_type == 0b01) {
// Community port
// Allow communication with promiscuous ports and other community
ports,
// but not with isolated ports
igr_vlan_entry.vlan_port_mask &= ~csr.vlan_isolated_mask;
}
}
} // vlan_igr_filter_ena
} // csr.vlan_ena
}
// Only allow forwarding to enabled ports
igr_vlan_entry.vlan_port_mask &= csr.port_fwd_ena;
// Update req with results
req.vlan_mask = igr_vlan_entry.vlan_port_mask & igr_mstp_entry.mstp_fwd_mask;
req.ifid
req.vlan_mirror
req.vlan_flood_dis
req.vlan_sec_fwd_ena
=
=
=
=
igr_vlan_entry.vlan_fid;
igr_vlan_entry.vlan_mirror_ena;
igr_vlan_entry.vlan_flood_dis;
igr_vlan_entry.vlan_sec_fwd_ena;
// Identical ingress and egress FID/VID.
// May be overruled later by egress VLAN handling.
// Note: ANA_L2 DMAC lookup always use req.efid, even when req.l3_fwd=0.
req.evid = req.ivid;
if (req.dmac[40]) {
// If MC, DA lookup must use EVID
req.efid = req.vsi_ena . req.evid;
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
125
Functional Descriptions
} else {
// If UC, DA lookup must use IFID
req.efid = req.ifid;
}
// Store vmid for later use (e.g. in rleg detection)
req.irleg = igr_vlan_entry.vmid;
req.erleg = req.irleg;
3.15.2.1
VLAN Table Update Engine
The VLAN Table Update Engine (TUPE) can be used to quickly update a large number of port masks in
the VLAN Table. For example, to support fast fail-over in scenarios with redundant forwarding paths. The
following table lists the TUPE related parameters that are outside the VLAN Table.
Table 88 •
VLAN Table Update Engine (TUPE) Parameters
Register/Field in ANA_L3:TUPE
Bits
Description
TUPE_MISC.TUPE_START
1
Start TUPE.
TUPE_MISC.TUPE_CTRL_VAL_ENA
1
Enable use of TUPE_CTRL_VAL and TUPE_CTRL_VAL_MASK.
TUPE_CTRL_BIT_ENA
1
Enable use of TUPE_CTRL_BIT_MASK.
TUPE_PORT_MASK_A_ENA
1
Enable use of TUPE_PORT_MASK_A.
TUPE_PORT_MASK_B_ENA
1
Enable use of TUPE_PORT_MASK_B
TUPE_COMB_MASK_ENA
1
Enable combined use of TUPE_CTRL_BIT_MASK and
TUPE_PORT_MASK_A.
TUPE_ADDR.TUPE_START_ADDR
13
First address in VLAN table for TUPE to process.
TUPE_ADDR.TUPE_END_ADDR
13
Last address in VLAN table for TUPE to process.
TUPE_CMD_PORT_MASK_CLR
TUPE_CMD_PORT_MASK_CLR1
53
TUPE command: Port mask bits to clear.
TUPE_CMD_PORT_MASK_SET
TUPE_CMD_PORT_MASK_SET1
53
TUPE command: Port mask bits to set.
TUPE_CTRL_VAL
16
TUPE parameter controlling which VLAN table entries to update.
TUPE_CTRL_VAL_MASK
16
TUPE parameter controlling which VLAN table entries to update.
TUPE_CTRL_BIT_MASK
16
TUPE parameter controlling which VLAN table entries to update.
TUPE_PORT_MASK_A
TUPE_PORT_MASK_A1
53
TUPE parameter controlling which VLAN table entries to update.
TUPE_PORT_MASK_B
TUPE_PORT_MASK_B1
53
TUPE parameter controlling which VLAN table entries to update.
The TUPE_CTRL field in the VLAN table can be used to classify VLANs into different groups, and the
VLAN_PORT_MASK for such groups of VLANs are quickly updated using TUPE. Using the parameters
listed, the TUPE_CTRL field in the VLAN table can be processed as a field of individual bits, a field with
one value, or a combination of the two.
For example, if a command for TUPE uses the following, the TUPE_CTRL field is treated as an 8-bit
value field and eight individual bits.
•
•
•
TUPE_CTRL_BIT_ENA = 1
TUPE_CTRL_BIT_MASK = 0x00ff
TUPE_CTRL_VAL_MASK = 0xff00
In order for TUPE to update a VLAN entry’s VLAN_PORT_MASK, the value part of TUPE_CTRL must
match the required value, and one or more bits of the bit part of TUPE_CTRL must be set.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
126
Functional Descriptions
If all bits in TUPE_CTRL are used as a value field, then a total of 216 groups can be created, but each
VLAN can only be member of one such group.
On the other end of the spectrum, if all bits in TUPE_CTRL are treated as individual bits, then only 16
groups can be created, but every VLAN can be member of any number of these groups.
In configurations that have fewer physical ports than the number of bits in the VLAN_PORT_MASK, such
bits can be used as an extension to the bit part of the TUPE_CTRL field.
Apart from the VLAN’s TUPE_CTRL, the value of the VLAN’s VLAN_PORT_MASK is also used to
decide whether to update a given VLAN table entry.
The following illustration depicts the TUPE functionality.
Figure 20 • VLAN Table Update Engine (TUPE)
VLAN Table (ANA_L3:VLAN)
TUPE_START_ADDR
TUPE_CTRL
Value part
Bit part
VLAN_PORT_MASK
...
Unused bits
Used bits
(physical ports)
TUPE_END_ADDR
Possibly new value of
VLAN_PORT_MASK
TUPE
Command
Parameters
(ANA_L3:TUPE)
TUPE Algorithm
The following pseudo code shows the full algorithm used by TUPE.
for (addr = csr.tupe_start_addr; addr < csr.tupe_end_addr; addr++) {
vlan_entry = vlan_tbl[addr];
if (
(// If enabled, check matching value
!csr.tupe_ctrl_val_ena
||
((vlan_entry.tupe_ctrl & csr.tupe_ctrl_val_mask) == csr.tupe_ctrl_val))
&&
(// If enabled, check if VLAN's tupe_ctrl has any bits overlapping
// with csr.tupe_CTRL_BIT_MASK
!csr.tupe_ctrl_bit_ena
||
((vlan_entry.tupe_ctrl & csr.tupe_ctrl_bit_mask) != 0))
&&
(// If enabled, check if VLAN's vlan_port_mask has any bits overlapping
// with csr.tupe_PORT_MASK_A
!csr.tupe_port_mask_a_ena
||
((vlan_entry.vlan_port_mask & csr.tupe_port_mask_a) != 0))
&&
(// Combined mode
// If enabled, check if VLAN's tupe_ctrl has any bits overlapping
// with TUPE_CTRL_BIT_MASK or VLAN's vlan_port_mask has any bits
// overlapping with TUPE_PORT_MASK_A
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
127
Functional Descriptions
// I.e. the bit mask part of TUPE_CTRL is extended with bits from
// vlan_port_maks.
!csr.tupe_comb_mask_ena
||
((vlan_entry.tupe_ctrl & csr.tupe_ctrl_bit_mask) != 0)
||
((vlan_entry.vlan_port_mask & csr.tupe_port_mask_a) != 0))
&&
(// If enabled, check if VLAN's vlan_port_mask has any bits overlapping
// with csr.tupe_PORT_MASK_B
!csr.tupe_port_mask_b_ena
||
((vlan_entry.vlan_port_mask & csr.tupe_port_mask_b) != 0))
) {
// vlan_port_mask must be updated for this addr
for (p = 0; p < port_count; p++) {
if (csr.tupe_cmd_port_mask_clr[p] == 1 &&
csr.tupe_cmd_port_mask_set[p] == 1) {
// clr+set => toggle
vlan_entry.vlan_port_mask[p] = !vlan_entry.vlan_port_mask[p];
} else if (csr.tupe_cmd_port_mask_clr[p] == 1) {
vlan_entry.vlan_port_mask[p] = 0;
} else if (csr.tupe_cmd_port_mask_set[p] == 1) {
vlan_entry.vlan_port_mask[p] = 1;
}
}
// Write back to VLAN table
vlan_tbl[addr] = vlan_entry;
}
3.16
VCAP LPM: Keys and Action
The IP addresses used for IP source/destination guard and for IP routing are stored in a VCAP in the
VCAP_SUPER block. The part of the VCAP_SUPER block allocated for this purpose is VCAP LPM
(Longest Path Match).
VCAP LPM encodes both the IP addresses (VCAP keys) and the action information associated with each
VCAP key.
The following table shows the different key types supported by the VCAP LPM.
Table 89 •
VCAP LPM Key and Sizes
Key Name
Key Size
Number of VCAP Words
SGL_IP4
33
1
DBL_IP4
64
2
SGL_IP6
129
4
DBL_IP6
256
8
The following table provides an overview of the VCAP LPM key. When programming an entry in VCAP
LPM, the associated key fields listed must be programmed in the listed order with the first field in the
table starting at bit 0 of the entry. For more information, see, Versatile Content-Aware Processor
(VCAP™), page 56.
Table 90 •
VCAP LPM Key Overview
Field Name
Short Description
Size
SGL_IP4
DST_FLAG
0=SIP, 1=DIP
1
x
DBL_IP4
SGL_IP6
DBL_IP6
x
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
128
Functional Descriptions
VCAP LPM Key Overview (continued)
Table 90 •
3.16.1
Field Name
Short Description
Size
SGL_IP4
DBL_IP4
SGL_IP6
DBL_IP6
IP4_XIP
IPv4 SIP/DIP
32
x
IP4_SIP
IPv4 SIP
32
x
IP4_DIP
IPv4 DIP
32
x
IP6_XIP
IPv6 SIP/DIP
128
IP6_SIP
IPv6 SIP
128
x
IP6_DIP
IPv6 DIP
128
x
x
VCAP LPM SGL_IP4 Key Details
The SGL_IP4 key is to be used for IPv4 UC routing as well as IPv4 Source/Destination Guard.
VCAP LPM SGL_IP4 Key Details
Table 91 •
3.16.2
Field Name
Description
Size
DST_FLAG
0: IP4_XIP is only to be used for SIP matching.
1: IP4_XIP is only to be used for DIP matching.
1
IP4_XIP
IPv4 address
32
VCAP LPM DBL_IP4 Key Details
The DBL_IP4 key is to be used for IPv4 MC routing.
Table 92 •
3.16.3
VCAP LPM DBL_IP4 Key Details
Field Name
Description
Size
IP4_SIP
IPv4 source address
32
IP4_DIP
IPv4 destination address
32
VCAP LPM SGL_IP6 Key Details
The SGL_IP6 key is to be used for IPv6 UC routing as well as IPv6 Source/Destination Guard.
Table 93 •
3.16.4
VCAP LPM SGL_IP6 Key Details
Field Name
Description
Size
DST_FLAG
0: IP6_XIP is only to be used for SIP matching
1: IP6_XIP is only to be used for DIP matching
1
IP6_XIP
IPv6 address
128
VCAP LPM DBL_IP6 Key Details
The DBL_IP6 key is to be used for IPv6 MC routing.
Table 94 •
VCAP LPM DBL_IP6 Key Details
Field Name
Description
Size
IP6_SIP
IPv6 source address
128
IP6_DIP
IPv6 destination address
128
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
129
Functional Descriptions
3.16.5
VCAP LPM Actions
VCAP LPM supports three different actions:
•
•
•
ARP_PTR
L3MC_PTR
ARP_ENTRY
The following table lists the actions and the key types for which they are intended to be used.
Table 95 •
VCAP LPM Action Selection
Action Name
Size
Description and Appropriate VCAP LPM Key Types
ARP_PTR
18
Provides pointer to ARP entry in ARP Table (ANA_L3:ARP).
LPM key types: SGL_IP4, SGL_IP6.
L3MC_PTR
10
Provides pointer to L3MC Table (ANA_L3:L3MC).
LPM key types: DBL_IP4, DBL_IP6.
ARP_ENTRY
62
ARP entry.
LPM key types: SGL_IP4, SGL_IP6.
The following table provides information about the VCAP LPM actions. When programming an action in
VCAP LPM, the associated action fields listed must be programmed in the listed order, with the first field
in the table starting at bit 0 of the action.
Table 96 •
VCAP LPM Actions
Field Name
Description and Encoding
Size
ARP_PTR L3MC_PTR ARP_ENTRY
Action Type
0: ARP_PTR
1: L3MC_PTR
2: ARP_ENTRY
3: Reserved
2
x
ARP_PTR
Pointer to entry in ARP Table (ANA_L3:ARP)
11
x
x
x
ARP_PTR_REMAP If this bit is set, ARP_PTR is used to point to an 1
_ENA
entry in the ARP pointer remap table (ANA_L3:
ARP_PTR_REMAP).
x
ECMP_CNT
Number of equal cost, multiple paths routes to 4
DIP. See IP Multicast Routing, page 141.
x
RGID
Route Group ID. Used for SIP RPF check. See 3
SIP RPF Check, page 144.
x
L3MC_PTR
Pointer to entry in L3MC Table
(ANA_L3:L3MC)
10
MAC_MSB
See ANA_L3:ARP:ARP_CFG_0.MAC_MSB.
16
x
MAC_LSB
See ANA_L3:ARP:ARP_CFG_1.MAC_LSB.
32
x
ARP_VMID
See ANA_L3:ARP:ARP_CFG_0.ARP_VMID.
7
x
ZERO_DMAC_CP
U_QU
See
3
ANA_L3:ARP:ARP_CFG_0.ZERO_DMAC_CP
U_QU.
SIP_RPF_ENA
See
ANA_L3:ARP:ARP_CFG_0.SIP_RPF_ENA.
SECUR_MATCH_
VMID_ENA
See
1
ANA_L3:ARP:ARP_CFG_0.SECUR_MATCH_
VMID_ENA.
x
1
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
130
Functional Descriptions
Table 96 •
VCAP LPM Actions (continued)
Field Name
Description and Encoding
SECUR_MATCH_
MAC_ENA
See
1
ANA_L3:ARP:ARP_CFG_0.SECUR_MATCH_
MAC_ENA.
ARP_ENA
See ANA_L3:ARP:ARP_CFG_0.ARP_ENA.
3.17
Size
ARP_PTR L3MC_PTR ARP_ENTRY
1
IP Processing
This section provides information about IP routing and IP security checks. The configuration parameters
for IP routing are located within the ANA_L3 configuration target.
Each frame is subject to two lookups in VCAP LPM. One lookup is used for looking up SIP, and the other
lookup is used for looking up DIP or DIP + SIP (for IP multicast frames).
3.17.1
IP Source/Destination Guard
For security purposes, the devices can be configured to identify specific combinations of the following
information and apply security rules based on that information.
•
•
(SMAC, SIP) or (VMID, SIP)
(DMAC, DIP) or (VMID, DIP)
The VCAP LPM and ARP table in ANA_L3 are used to perform matching. The result of the matching is
available for security rules in ANA_ACL through the following VCAP fields:
•
•
L3_SMAC_SIP_MATCH. Set to 1 if (VMID, SIP) and/or (SMAC, SIP) match was found.
L3_DMAC_DIP_MATCH. Set to 1 if (VMID, DIP) and/or (DMAC, DIP) match was found.
IP source/destination guard check can be enabled per port using COMMON:SIP_SECURE_ENA and
COMMON:DIP_SECURE_ENA.
When enabled, the frame’s DIP and the frame’s SIP are each looked up in VCAP LPM. The associated
VCAP action provides an index to an ARP Table entry in which the required SMAC/DMAC and/or VMID
is configured.
The following pseudo code specifies the behavior of the IP Source Guard checks.
// Determine value of req.l3_sip_match (available in ANA_ACL as
L3_SMAC_SIP_MATCH)
if (!req.ip4_avail && !req.ip6_avail) {
req.l3_sip_match = 1;
return;
}
if (csr.sip_cmp_ena(req.port_num)) {
req.l3_sip_match = 0;
} else {
req.l3_sip_match = 1;
}
if (!LpmHit()) {
return;
}
if (req.ip4_avail) {
csr.secur_ip4_lpm_found_sticky = 1;
}
if (req.ip6_avail) {
csr.secur_ip6_lpm_found_sticky = 1;
}
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
131
Functional Descriptions
sip_arp_entry = csr.arp_tbl[sip_lpm_entry.base_ptr +
(ecmp_ac % (sip_lpm_entry.ecmp_cnt+1))];
if ((sip_arp_entry.secur_match_vmid_ena == 0 ||
igr_vlan_entry.vmid == sip_arp_entry.arp_vmid)
&&
(sip_arp_entry.secur_match_mac_ena == 0 ||
req.smac == sip_arp_entry.mac)) {
req.l3_sip_match = 1;
if (req.ip4_avail) {
csr.secur_ip4_sip_match_sticky = 1;
} else {
csr.secur_ip6_sip_match_sticky = 1;
}
}
if (req.l3_sip_match == 0) {
csr.secur_sip_fail_sticky = 1;
}
The IP Destination Guard check works in the same way as the SIP check, except for the following:
•
•
DIP check is not performed if frame has a multicast DMAC.
DIP check is not performed if router leg has been matched.
The following pseudo code specifies the behavior of the IP Destination Guard checks.
// Determine value of req.l3_sip_match (available in ANA_ACL as
L3_SMAC_SIP_MATCH)
if (!req.ip4_avail && !req.ip6_avail) {
req.l3_sip_match = 1;
return;
}
if (csr.sip_cmp_ena(req.port_num)) {
req.l3_sip_match = 0;
} else {
req.l3_sip_match = 1;
}
if (!LpmHit()) {
return;
}
if (req.ip4_avail) {
csr.secur_ip4_lpm_found_sticky = 1;
}
if (req.ip6_avail) {
csr.secur_ip6_lpm_found_sticky = 1;
}
sip_arp_entry = csr.arp_tbl[sip_lpm_entry.arp_ptr];
if ((sip_arp_entry.secur_match_vmid_ena == 0 ||
igr_vlan_entry.vmid == sip_arp_entry.arp_vmid)
&&
(sip_arp_entry.secur_match_mac_ena == 0 ||
req.smac == sip_arp_entry.mac)) {
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
132
Functional Descriptions
req.l3_sip_match = 1;
if (req.ip4_avail) {
csr.secur_ip4_sip_match_sticky = 1;
} else {
csr.secur_ip6_sip_match_sticky = 1;
}
}
if (req.l3_sip_match == 0) {
csr.secur_sip_fail_sticky = 1;
}
3.17.2
IP Routing
The devices support routing of IPv4 and IPv6 unicast and multicast packets through the 128 router
interfaces, also known as “router legs”. Each router leg is attached to a VLAN.
The following illustration shows a configuration with three VLANs, each with an attached router leg for
routing IP packets between the VLANs. Port 11 is member of both VLAN 1 and VLAN 2.
When a packet is being routed from one VLAN (the ingress VLAN) to another VLAN (the egress VLAN),
the VID of the ingress VLAN is termed IVID, and the VID of the egress VLAN is termed the EVID.
Figure 21 • Router Model
Router
8
Router Leg
Router Leg
Router Leg
VLAN 1
VLAN 2
VLAN 3
9
10 11
12
13
14 15 16
17 18
19
Within the devices, a router leg is identified by a 7-bit VMID value. When a packet is being routed, it is
then received by the router entity using a router leg identified by an ingress VMID (or IVMID) and
transmitted on an egress router leg identified by an egress VMID (or EVMID).
IP routing, also known as L3 forwarding, is only supported in VLAN-aware mode.
3.17.3
Frame Types for IP Routing
In order for IP packets to be routed by the devices, the following conditions must be met.
•
•
•
•
3.17.3.1
IPv4 packets must not contain options.
IPv6 packets must not contain hop-by-hop options.
Optionally packets with some illegal SIP and DIP addresses can be filtered. For more information,
see Illegal IPv4 Addresses, page 137 and Illegal IPv6 Addresses, page 137.
IPv4 header checksum must be correct.
Routing Table Overview
The following illustration provides an overview of the table lookups involved in IP unicast routing within
the L3 part of the analyzer.
The VCAP and ARP table lookups are performed in parallel with the VLAN/MSTP/VMID table lookups. If
the frame does not match a router leg, the result of VCAP and ARP table lookups are not used for
routing.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
133
Functional Descriptions
Figure 22 • Unicast Routing Table Overview
(DIP)
Classified VID
VCAP
VLAN
Table
VCAP action type == arp_ptr:
ARP_PTR
ARP
Table
VLAN_MSTP_PTR
MSTP
Table
VMID
VMID
Table
Ingress VLAN/
ingress router leg
VCAP action type ==
arp_entry
L2 Forwarding Decision
for Ingress VLAN
IP Unicast Routing Decision
ARP_VMID
VMID
Table
RLEG_EVID
VLAN
Table
Egress router leg/
Egress VLAN
MSTP_PTR
MSTP
Table
L2 Forwarding Decision
for Egress VLAN
The following illustration provides an overview of the table lookups involved in IP multicast routing within
the L3 part of the analyzer.
The VCAP and L3MC table lookups are performed in parallel with the VLAN/MSTP/VMID table lookups.
If the frame does not match a router leg, the result of VCAP and L3MC table lookups are not used for
routing.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
134
Functional Descriptions
Figure 23 • Multicast Routing Table Overview
Classified VID
First pass: (DIP,SIP)
VCAP
First pass:
L3MC-PTR
L3MC
Table
Second pass:
L3MC_PTR
from first pass
VLAN
Table
VLAN_MSTP_PTR
MSTP
Table
VMID
VMID
Table
Ingress VLAN/
Ingress router leg
L2 Forwarding Decision
for Ingress VLAN
IP Multicast Routing Decision
Egress VMID
VMID
Table
RLEG_EVID
VLAN
Table
Egress router leg/
egress VLAN
MSTP_PTR
MSTP
Table
L2 Forwarding Decision
for Egress VLAN
3.17.3.2
Ingress Router Leg Lookup
The VID used to determine the ingress router leg is the classified VID. The classified VID can be
deducted based on a variety of parameters, such as VLAN tag or ingress port. For more information, see
VLAN Classification, page 107.
A total of 128 router legs are supported. Each router leg can be used for both IPv4 and IPv6 unicast and
multicast routing. A maximum of one router leg per VLAN is supported.
When processing incoming frames, the classified VID is used to index the VLAN table. The RLEG_ENA
parameter determines if the VLAN is enabled for routing of packets, and if so, the VMID is used to index
the VMID table. The flow is depicted in the following illustration.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
135
Functional Descriptions
Figure 24 • Ingress Router Leg Lookup Flow
VMID Table
(Router leg
configuration)
VLAN Table
Classified
VID
VMID
VLAN_RLEG_ENA
RLEG_IP4_UC_ENA
RLEG_IP4_MC_ENA
RLEG_IP4_ICMP_REDIR_ENA
RLEG_IP4_VRID_ENA
RLEG_IP6_UC_ENA
RLEG_IP6_MC_ENA
RLEG_IP6_ICMP_REDIR_ENA
RLEG_IP6_VRID_ENA
RLEG_EVID(11:0)
RLEG_IP4_VRID0(7:0)
RLEG_IP6_VRID1(7:0)
RLEG_IP4_MC_TTL(7:0)
RLEG_IP6_MC_TTL(7:0)
3.17.3.2.1 Unicast Router Leg Detection
On L2, up to three different MAC addresses are used to identify the router leg:
•
•
The normal router leg MAC address. This MAC address consists of a base address that is
configured using COMMON:RLEG_CFG_0.RLEG_MAC_LSB and
COMMON:RLEG_CFG_0.RLEG_MAC_MSB.
To have different MAC addresses for each router leg, the three least significant bytes of the base
MAC address can optionally be incremented by the Classified VID or the VMID. This is configured
using COMMON:RLEG_CFG_1.RLEG_MAC_TYPE_SEL.
VRRP MAC address for IPv4. This MAC address consists of a base address that is configured using
COMMON:VRRP_IP4_CFG_0.VRRP_IP4_BASE_MAC_MID and
COMMON:VRRP_IP4_CFG_0.VRRP_IP4_BASE_MAC_HIGH.
For each router leg, the least signficant byte is configured per router leg using
VMID:VRRP_CFG.RLEG_IP4_VRID. Up to two VRID values are supported per router leg.
•
Use of VRRP for IPv4 is enabled using VMID:RLEG_CTRL.RLEG_IP4_VRID_ENA.
VRRP MAC address for IPv6. This is configured in the same manner as VRRP MAC address for
IPv4.
The matching of router leg MAC address for unicast packets is shown in the following illustration.
Figure 25 • Ingress Router Leg MAC Address Matching for Unicast Packets
From VMID Table:
Frame is IPv4/6
RLEG_IP4/6_UC_ENA
AND
RLEG_IP4/6_VRID_ENA
RLEG_IP4/6_VRID
Normal base MAC address
COMMON:RLEG_CFG_1.RLEG_MAC_MSB
COMMON:RLEG_CFG_0.RLEG_MAC_LSB
24
IVMID
Classified VID
0
RLEG selector
COMMON:RLEG_CFG_1.RLEG_MAC_TYPE_SEL
(47:0)
24
+
Frame s DMAC matches
Router s MAC address
=?
(7:0)
(47:8)
8
48
=?
=?
AND
OR
AND
Router leg MAC
address match
Frame s DMAC
matches VRRP MAC
address
Frame.DMAC
VRRP Base MAC address
COMMON:VRRP_IP4/6_CFG_0.VRRP_IP4/6_BASE_MAC_HIGH
COMMON:VRRP_IP4/6_CFG_1.VRRP_IP4/6_BASE_MAC_MID
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
136
Functional Descriptions
The packet is a candidate for unicast routing if a frame’s DMAC matches one of the router leg MAC
addresses. Packets sent to the router itself will also match the router leg MAC address, but these will be
caught through entries in the ARP table.
Despite matching a router leg MAC address, routing is not performed for any of the following reasons. If
any of following criteria are met, the frame may be redirected to the CPU, depending on configuration
parameters.
•
•
•
•
•
It is not an IP packet (for example, an ARP reply).
There are IP header errors.
DIP or SIP address is illegal (optional).
Packet contains IPv4 options/IPv6 hop-by-hop options.
IPv4 TTL or IPv6 HL is less than two.
3.17.3.2.2 Multicast Router Leg Detection
For each router leg, IP multicast routing can be enabled using VMID:RLEG_CTRL.RLEG_IP4_MC_ENA
and VMID:RLEG_CTRL.RLEG_IP6_MC_ENA.
In addition to having multicast routing enabled for the router leg configured for the VLAN, the frame’s
DMAC must be within a specific range in order for the packet to be candidate for IPv4/6 routing.
•
•
IPv4 DMAC range: 01-00-5E-00-00-00 to 01-00-5E-7F-FF-FF
IPv6 DMAC range: 33-33-00-00-00-00 to 33-33-FF-7F-FF-FF
Despite having a DMAC address within the required range, routing is not performed for any of the
following reasons:
•
•
•
•
There are IP header errors.
DIP or SIP address is illegal (optional).
Packet contains IPv4 options/IPv6 hop-by-hop options
IPv4 TTL or IPv6 HL is less than two.
If any of above criteria are met, then the frame may be redirected to CPU, depending on configuration
parameters.
The frame is still L2 forwarded if no router leg match is found.
3.17.3.2.3 Illegal IPv4 Addresses
Use the ROUTING_CFG.IP4_SIP_ADDR_VIOLATION_REDIR_ENA parameters to configure each of
the following SIP address ranges to be considered illegal.
•
•
•
0.0.0.0 to 0.255.255.255 (IP network zero)
127.0.0.0 to 127.255.255.255 (IP loopback network)
224.0.0.0 to 255.255.255.255 (IP multicast/experimental/broadcast)
Frames with an illegal SIP can be redirected to the CPU using
CPU_RLEG_IP_HDR_FAIL_REDIR_ENA.
Use the ROUTING_CFG.IP4_DIP_ADDR_VIOLATION_REDIR_ENA parameters to configure each of
the following DIP address ranges to be considered illegal.
•
•
•
0.0.0.0 to 0.255.255.255 (IP network zero)
127.0.0.0 to 127.255.255.255 (IP loopback network)
240.0.0.0 to 255.255.255.254 (IP experimental)
Frames with an illegal DIP can be redirected to the CPU using
CPU_RLEG_IP_HDR_FAIL_REDIR_ENA.
3.17.3.2.4 Illegal IPv6 Addresses
Use the ROUTING_CFG.IP6_SIP_ADDR_VIOLATION_REDIR_ENA parameters to configure each of
the following SIP address ranges to be considered illegal.
•
•
•
::/128 (unspecified address)
::1/128 (loopback address)
ff00::/8 (IPv6 multicast addresses)
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
137
Functional Descriptions
Frames with an illegal SIP can be redirected to the CPU using
CPU_RLEG_IP_HDR_FAIL_REDIR_ENA.
Use the ROUTING_CFG.IP6_DIP_ADDR_VIOLATION_REDIR_ENA parameters to configure each of
the following DIP address ranges to be considered illegal.
•
•
::/128 (unspecified address)
::1/128 (loopback address)
Frames with an illegal DIP can be redirected to the CPU using
CPU_RLEG_IP_HDR_FAIL_REDIR_ENA.
3.17.3.3
Unicast Routing
The IPv4/IPv6 unicast forwarding table in the Analyzer is configured with known routes. There are
typically two types of routes: Local IP and Remote IP.
•
•
Local IP networks directly accessible through the router. These entries return the DMAC address of
the destination host and correspond to an ARP lookup.
Remote IP networks accessible through a router. These entries return the DMAC address of the
next-hop router.
If frames are deemed suitable for IP unicast routing, a DIP lookup is performed in the Longest Prefix
Match (LPM) table. The lookup is a Classless Inter-Domain Routing (CIDR) lookup. That is, all network
sizes are supported.
For IP addresses in local IP networks without corresponding MAC addresses, LPM entry with a
corresponding ARP entry with a zero MAC address should be configured. This results in redirecting the
matching frames to the CPU and thus allows the CPU to exchange ARP/NDP messages with the stations
on the local IP networks to request their MAC address and afterwards use this information to update the
ARP table.
Packets with IVMID = EVMID (packets that are to be routed back to the router leg on which they were
received) can optionally be redirected to the CPU such that the CPU can generate an ICMP Redirect
message. This is configurable using VMID:RLEG_CTRL.RLEG_IP4_ICMP_REDIR_ENA and
VMID:RLEG_CTRL.RLEG_IP6_ICMP_REDIR_ENA.
If such packets are not redirected to the CPU, they are routed.
IVMID and EVMID are configured using VLAN:VMID_CFG.VMID and ARP:ARP_CFG_0.ARP_VMID.
The following illustration shows an IPv4 unicast routing example. IPv6 unicast routing works identically to
IPv4 unicast routing, with the exception that each of the IPv6 addresses occupies four times as much
space in VCAP LPM.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
138
Functional Descriptions
Figure 26 • IP Unicast Routing Example
Router leg 1 (VMID=1)
MAC: 0x001122330001
IPv4: 1.1.1.0
o
n
Router leg 2 (VMID=2)
MAC: 0x001122330002
IPv4: 2.2.2.0
Router
m
a
b
c
VLAN2
IPv4 network: 2.2.2.0/24
VLAN1
IPv4 network 1.1.1.0/24
Host A1
IPv4: 1.1.1.1
MAC: 0x000001010101
Host A2
IPv4: 1.1.1.2
MAC: 0x000001010102
Router A3
IPv4: 1.1.1.3
MAC: 0x000001010103
Host B3
IPv4: 2.2.2.3
MAC: 0x000002020203
Router B2
IPv4: 2.2.2.2
MAC: 0x000002020202
Default Router
IPv4 network
*.*.*.*/0
IPv4 network
5.5.0.0/12
IPv4 network 3.3.0.0/16
Host B1
IPv4: 2.2.2.1
MAC: 0x000002020201
IPv4 network 4.4.0.0/16
LPM VCAP
Valid
DIP
0
x
x
x
x
x
m+7
1
1.1.1.0
32
0
m+7
1
000000000000
X
m+6
1
1.1.1.1
32
0
m+6
0
000001010101
1
m+5
1
1.1.1.2
32
0
m+5
0
000001010102
1
m+4
1
1.1.1.3
32
0
m+4
0
000001010103
1
m+3
1
2.2.2.0
32
0
m+3
1
000000000000
2
m+2
1
2.2.2.1
32
0
m+2
0
000002020201
2
m+1
1
2.2.2.2
32
0
m+1
0
000002020202
2
m
1
2.2.2.3
32
0
m
0
000002020203
2
...
Up to
16,384 IPv4 entries / 4,096 IPv6 entries
ARP Table
Prefix
Length
Index
Search Direction
VCAP Actions
ECMP
ARP IDX
CPU
DMAC
EVMID
x
x
...
...
...
n+5
1
1.1.1.0
24
0
n+5
1
000000000000
x
n+4
1
2.2.2.0
24
0
n+5
0
000001010103
1
n+3
1
3.3.0.0
16
0
n+4
0
000001010103
1
n+2
1
4.4.0.0
16
0
0
0
000002020202
2
n+1
1
5.5.0.0
12
1
n+2
x
x
x
n
0
x
x
x
x
x
x
x
0
1
0.0.0.0
0
0
0
0
000002020202
2
...
...
Known
local
hosts
2, 048 entries
VCAP Entries
Known
Network
Equal
Cost
Network
Default gateway
Ports o, n, and m are connected to Router A3, Host A1, and Host A2. These stations are included in an
IP subnet associated with VLAN 1 and connected to the router by router leg 1. Router leg 1’s MAC
address is shown.
Ports a, b, and c are connected to Router B2, Host B1, and Host B3. These stations are included in an IP
subnet associated with VLAN 2 and connected to the router by router leg 2.
The router leg MAC addresses in the example offsets the base MAC address by the respective router
leg’s VMID.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
139
Functional Descriptions
Traffic destined within a subnet is L2-forwarded. For example, traffic from Host A1 to Host A2 is L2
forwarded.
Traffic destined outside a subnet is sent to the router using the router leg’s MAC address. The router
performs the routing decision as follows:
1.
2.
3.
4.
Known local host. If the destination IP address is known to be a local host (with the full IP address
installed in the VCAP LPM table), the router takes the local host DMAC address and egress router
leg VMID (EVMID) from the ARP table entry pointed to by the ARP_IDX of the VCAP Action. For
example, if traffic sent from Host A1 to B1 is routed using LPM entry m+2 (2.2.2.1/32) and ARP entry
m + 2, the local host’s DMAC address is found to be 0x000002020201 and egress router leg to be
RLEG2 (that is, VMID = 2).
Known longest prefix. If the full destination IP address is not known, the router finds the longest
matching IP prefix and uses it to determine the next hop DMAC address and egress router leg. For
example, traffic sent from host A1 to host 4.4.4.2 is routed using LPM entry n + 2 (the 4.4.0.0 subnet
is reached through Router B2) and using ARP entry 0, the next hop’s DMAC address is found to be
0x000002020202 and egress router leg to be RLEG2 (for example, VMID = 2).
Known equal cost multiple paths (ECMP). If the full destination IP address is not known by the
router and the longest matching IP prefix is an equal cost path, the next hop DMAC address and
egress router leg is derived from one of up to 16 ARP entries. For example, traffic sent from host A1
to host 5.5.5.13 is routed using VCAP LPM entry n + 1. The corresponding VCAP action has
ECMP = 1, so the ARP table entry is chosen to be either n + 2 or n + 3, based on a pseudo random
number. If entry n + 2 is chosen, the next hop’s DMAC address is found to be 0x000001010103
(Router A3) and egress router leg to be RLEG1. If entry n + 3 is chosen, the next hop’s DMAC
address is found to be 0x000002020202 (Router B2) and egress router leg to be RLEG2.
Default gateway. In order to forward packets destined to unknown subnets to a default router, a
default rule can be configured for the VCAP LPM. This is illustrated in the IP Unicast Routing
example as a “0.0.0.0” rule. For example, traffic sent from host A1 to host 8.9.4.2 is routed using
LPM entry 0 (the default router is reached through Router B2) and ARP entry 0, the next hop’s
DMAC address is found to be 0x000002020202 and egress Router Leg to be RLEG2.
When routing packets, the router replaces the frame’s DMAC with the ARP table’s DMAC and replaces
the SMAC with MAC address associated with the egress router leg. The classified VID is replaced by the
egress VID (VMID:RLEG_CTRL.RLEG_EVID). The TTL/HL is decremented by 1. Note that the VMID
tables (ANA_L3:VMID and REW:VMID) and the router leg MAC address must be configured consistently
in the analyzer Layer 3 and rewriter.
If host A2 wants to send traffic to a host in subnet 3.3.0.0/16, the host issues an ARP request and gets a
response to send traffic to router A3. Host A2 can choose to ignore this request, in which case, the router
routes to router A3 in the same VLAN.
Local networks 1.1.1.0/24 and 2.2.2.0/24 are also configured. Hosts and routers located in these
networks can be directly L2 accessed. This includes IP addresses 1.1.1.0 and 2.2.2.0, which are the IP
addresses of the router in the respective subnets to be used for IP management traffic, for example.
3.17.3.3.1 Encoding ARP Entry in VCAP Action
Instead of using an entry in the ARP table, the ARP information can alternatively be written into the
VCAP action of the LPM entry so as to not be limited by the size of the ARP table.
ARP entries written into a VCAP actions have the following limitations compared to ARP entries in the
ARP table.
•
•
•
ECMP cannot be supported. If there are multiple paths to a given subnet, then ARP table entries
must be used.
RGID cannot be configured. If RGIDs of SIP RPF are used, then ARP table entries must be used for
such routes.
Alternative Next Hop configuration cannot be supported. For example, if Alternative Next Hop
configuration is required, then ARP table entries must be used.
3.17.3.3.2 ARP Pointer Remap
An ARP Pointer Remap table is available to support fast fail-over when the next hop changes for a large
group of LPM VCAP entries.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
140
Functional Descriptions
By setting ARP_PTR_REMAP_ENA=1 in LPM VCAP action, the ARP_PTR in the VCAP action is used
to address an entry in the ARP_PTR_REMAP table and through this, new ARP_PTR and ECMP_CNT
values are looked up and used for lookup in the ARP table. Thus instead of updating ARP_PTR and
ECMP_CNT for many LPM VCAP entries, only the corresponding entry in ARP_PTR_REMAP needs to
be updated.
The following illustration depicts both where ARP Pointer remapping is not used, as well as where it is
used; that is, ARP_PTR_REMAP_ENA = 1.
Figure 27 • ARP Pointer Remapping
ARP_ PTR_ REMAP Table not used
ANA_L3: ARP
LPM VCAP Action
( action type: ARP_ PTR)
ANA_L3: ARP_ PTR_ REMAP
ARP_ PTR
ARP_ PTR_ REMAP_ ENA=0
ECMP_ CNT
ARP_ PTR
ECMP_ CNT
RGID
ARP_ PTR remapped through
ARP_ PTR_ REMAP Table
ANA_L3: ARP
LPM VCAP Action
( action type: ARP_ PTR)
ANA_L3: ARP_ PTR_ REMAP
ARP_ PTR
ARP_ PTR_ REMAP_ ENA=1
ECMP_ CNT
RGID
3.17.3.4
ARP_ PTR
ECMP_ CNT
IP Multicast Routing
The multicast system is split into two stages, stage 1 and stage 2.
In stage 1, the frame is received on a front port and the IP multicast system in ANA_L3 is activated. This
stage is used to ensure L2 forwarding to all relevant ports in the ingress VLAN as well as ingress
mirroring. If the frame needs to be L3 forwarded to other VLANs, an internal port module called virtual
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
141
Functional Descriptions
device 0 (VD0) also receives an L2 copy, together with information about the number of VLANs that
receive a routed copy of the frame.
In stage 2, the analyzer processes each frame copy from VD0, and L3 forwards each frame copy to its
egress VLAN.
In stage 1, ANA_L3 uses the VCAP LPM to determine the forwarding of the frame. Typically, two types of
VCAP LPM multicast entries exist: source-specific and source-independent.
•
•
Source specific IP multicast groups, where the same group IP address can be used by multiple
sources. Such groups are denoted (S,G).
Source independent IP multicast groups, where the group IP address uniquely identifies the IP
multicast flow. Such groups are denoted (*,G).
IPv4 multicast groups occupies two entries in the VCAP LPM, and IPv6 multicast groups occupies eight
entries. Source-specific multicast groups must be placed with higher precedence than sourceindependent multicast groups.
A matching entry in the VCAP LPM results in an index (L3MC_IDX) to an entry in the L3MC Table.
Each L3MC table entry contains a list of egress router legs to which frames are routed. Upon removing
the ingress router leg from the list, the required number of routed multicast copies is calculated and this
number (L3MC_COPY_CNT) is sent to VD0.
Stage 1 L2 forwards the frame. ANA_ACL can be used to limit the L2 forwarding, for example, to support
IGMP/MLD snooping.
For each L3MC entry, it can optionally be configured that routing is only performed if the frame was
received by a specific ingress router leg. This is termed reverse path forwarding check and is configured
using L3MC:L3MC_CTRL.RPF_CHK_ENA and L3MC:L3MC_CTRL.RPF_VMID.
Note that this RPF check is unrelated to the SIP RPF check. For more information about the SIP RPF
check, see SIP RPF Check, page 144.
Reverse path forwarding check does not affect the L2 forwarding decision.
In stage 2, VD0 replicates the frame according to L3MC_COPY_CNT, and L3MC_IDX is written into the
frame’s IFH.
For each copy, which ANA_L3 receives from VD0 during stage 2, L3MC_IDX from IFH is used to lookup
the L3MC table entry and thus find the list of egress router legs that require a routed copy. The egress
router leg is used to determine the egress VID which in turn is used to perform (VID, DMAC) lookup in
the MAC table for L2 forwarding within the egress VLAN.
For each egress router leg, it can be configured that frames are only L3 forwarded to the router leg if the
TTL/HL of the packet is above a certain value. This is configured using
VMID:VMID_MC.RLEG_IP4_MC_TTL and VMID:VMID_MC.RLEG_IP6_MC_TTL.
In stage 2, both learning and ingress filtering is disabled.
The following illustration shows an IPv4 multicast routing example. IPv6 multicast routing works
identically to IPv4 multicast routing, with the exception that the IPv6 entries occupies four times as much
space in VCAP LPM.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
142
Functional Descriptions
Figure 28 • IP Multicast Routing Example
Router
Router
leg 1
VLAN 1
IP network 1.1.1.0/24
8
9
1.1.1.1
1.1.1.3
10
VLAN 2
IP network 2.2.2.0/24
11
2.2.2.1
1.1.1.2
Sender
Router
leg 2
2.2.2.2
Receiver 1
2.2.2.3
Receiver 2
Receiver 3
LPM VCAP
SIP
CPU
l3mc_idx
EVMID_MASK
RPF_CHK_
(Router leg bit mask)
ENA
128 bits
RPF_
VMID
1
230.1.1.1 1.1.1.3
0
0
1
0x6
1
1
n+2
1
230.1.1.1 2.2.2.2
1
1
1
0xFF
0
x
n
1
230.1.1.2 2.2.2.2
1
2
x
x
x
x
1
230.1.1.1
x
1023
x
x
x
x
0
...
n+4
x
1024 entries
G
L3MC Table
Index
...
Up to
8192 IPv4 entries /
2096 IPv6 entries
Valid
Search Direction
VCAP
Actions
VCAP Entries
Index
A sender host with IPv4 address 1.1.1.3 is transmitting IPv4 multicast frames to the group address
230.1.1.1 and DMAC = 0x01005E010101. The frames must be L2 forwarded to receivers in VLAN 1 and
L3 forwarded to receivers in VLAN 2. For the latter, an entry for the (1.1.1.3, 230.1.1.1) pair is added to
the VCAP LPM.
3.17.3.4.1 Stage 1
•
•
•
•
•
•
Lookup of (SIP,G) = (1.1.1.3, 230.1.1.1) in VCAP LPM returns L3MC_IDX = 0 and a corresponding
entry in L3MC table. L3MC_IDX = 0 is inserted into the IFH.
The L3MC entry has RPF check enabled (RPF_ENA = 1). Because the frame has been received
through the specified router leg, L3 forwarding is allowed.
The L3MC entry specifies that frames are forwarded to router leg 1 and 2. Because the frame has
been received on router leg 1, only router leg 2 needs a routed copy. In other words, the number of
L3 frame copies required is set to 1.
If the frame’s TTL is = 0x600.
x
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
150
Functional Descriptions
Field Name
Description
Size
ETYPE
Frame’s EtherType
Overloading:
OAM Y.1731 frames: ETYPE[6:0] contains OAM MEL
flags, see the following. OAM_Y1731 is set to 1 to
indicate the overloading of ETYPE.
16
IP4_VID
MAC_ETYPE
ARP
IP4_TCP_UDP
IP4_OTHER
CUSTOM_2
IP6_VID
IP_7TUPLE
CUSTOM_1
Table 103 • VCAP IS2 Key Overview (continued)
x
OAM MEL flags:
Encoding of MD level/MEG level (MEL). One bit for
each level where lowest level encoded as zero.
The following keys can be generated:
MEL=0: 0b0000000
MEL=1: 0b0000001
MEL=2: 0b0000011
MEL=3: 0b0000111
MEL=4: 0b0001111
MEL=5: 0b0011111
MEL=6: 0b0111111
MEL=7: 0b1111111
Together with the mask, the following kinds of rules
may be created:
- Exact match. Fx. MEL = 2: 0b0000011
- Below. Fx. MEL< = 4: 0b000XXXX
- Above. Fx. MEL> = 5: 0bXX11111
- Between. Fx. 3< = MEL< = 5: 0b00XX111,
where 'X' means don't care.
IP4
Frame type flag indicating the frame is an IPv4 frame. 1
Set if frame is IPv4 frame (EtherType = 0x800 and IP
version = 4)
x x
L2_PAYLOAD_ETYPE
Byte 0-7 of L2 payload after Type/Len field.
Overloading:
OAM Y.1731 frames (OAM_Y1731 = 1):
Bytes 0-3: OAM PDU bytes 0-3
Bytes 4-5: OAM_MEPID
Bytes 6-7: Unused.
64
L3_FRAGMENT
Set if IPv4 frame is fragmented (more fragments
flag = 1 or fragments offset > 0).
1
x x
L3_FRAG_OFS_GT0
Set if IPv4 frame is fragmented but not the first
fragment (fragments offset > 0)
1
x x
ARP_ADDR_SPACE_O
K
Set if hardware address is Ethernet.
1
x
ARP_PROTO_SPACE_
OK
Set if protocol address space is 0x0800.
1
x
ARP_LEN_OK
Set if Hardware address length = 6 (Ethernet) and IP
address length = 4 (IP).
1
x
ARP_TARGET_MATCH
Target Hardware Address = SMAC (RARP).
1
x
ARP_SENDER_MATCH Sender Hardware Address = SMAC (ARP).
1
x
x
x
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
151
Functional Descriptions
Field Name
Description
Size
IP4_VID
MAC_ETYPE
ARP
IP4_TCP_UDP
IP4_OTHER
CUSTOM_2
IP6_VID
IP_7TUPLE
CUSTOM_1
Table 103 • VCAP IS2 Key Overview (continued)
ARP_OPCODE_UNKNO Set if ARP opcode is none of the below mentioned.
WN
1
x
ARP_OPCODE
ARP opcode.
Only valid if ARP_OPCODE_UNKNOWN is cleared.
0: ARP request.
1: ARP reply.
2: RARP request.
3: RARP reply.
2
x
L3_OPTIONS
Set if IPv4 frame contains options (IP len > 5). IP
options are not parsed.
1
x x
L3_TTL_GT0
Set if IPv4 TTL / IPv6 hop limit is greater than 0.
1
x x
x
L3_TOS
Frame's IPv4/IPv6 DSCP and ECN fields.
8
x x
x
L3_IP4_DIP
IPv4 frames: Destination IPv4 address.
IPv6 frames: Source IPv6 address, bits 63:32.
32
x
x x x
L3_IP4_SIP
IPv4 frames: Source IPv4 address.
IPv6 frames: Source IPv6 address, bits 31:0.
32
x
x x x
L3_IP6_DIP
IPv6 frames: Destination IPv6 address.
IPv4 frames: Bits 31:0: Destination IPv4 address.
128
x x
L3_IP6_SIP
IPv6 frames: Source IPv6 address.
IPv4 frames: Bits 31:0: Source IPv4 address.
128
x x
DIP_EQ_SIP
Set if destination IP address is equal to source IP
address.
1
x x x
L3_IP_PROTO
IPv4 frames (IP4 = 1): IP protocol.
IPv6 frames (IP4 = 0): Next header.
8
x
TCP_UDP
Frame type flag indicating the frame is a TCP or UDP
frame.
Set if frame is IPv4/IPv6 TCP or UDP frame (IP
protocol/next header equals 6 or 17).
1
TCP
Frame type flag indicating the frame is a TCP frame. 1
Set if frame is IPv4 TCP frame (IP protocol = 6) or IPv6
TCP frames (Next header = 6)
x
x
L4_DPORT
TCP/UDP destination port.
Overloading for IP_7TUPLE:
Non-TCP/UDP IP frames:
L4_DPORT = L3_IP_PROTO.
16
x
x
L4_SPORT
TCP/UDP source port.
16
x
x
L4_RNG
Range mask. Range types: SPORT, DPORT, SPORT
or DPORT, VID, DSCP, custom.
Input into range checkers is taken from classified
results (VID, DSCP) and frame (SPORT, DPORT,
custom).
8
x
x
SPORT_EQ_DPORT
Set if TCP/UDP source port equals TCP/UDP
destination port.
1
x
x
x
x
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
152
Functional Descriptions
IP4_VID
MAC_ETYPE
ARP
IP4_TCP_UDP
IP4_OTHER
CUSTOM_2
IP6_VID
IP_7TUPLE
CUSTOM_1
Table 103 • VCAP IS2 Key Overview (continued)
Field Name
Description
Size
SEQUENCE_EQ0
Set if TCP sequence number is 0.
1
x
x
L4_FIN
TCP flag FIN.
1
x
x
L4_SYN
TCP flag SYN.
1
x
x
L4_RST
TCP flag RST.
1
x
x
L4_PSH
TCP flag PSH.
1
x
x
L4_ACK
TCP flag ACK.
1
x
x
L4_URG
TCP flag URG.
1
x
x
L3_PAYLOAD
Payload bytes after IP header.
96
IPv4: IPv4 options are not parsed so payload is always
taken 20 bytes after the start of the IPv4 header.
L4_PAYLOAD
Payload bytes after TCP/UDP header.
64
Overloading for IP_7TUPLE:
Non TCP/UDP frames (TCP_UDP = 0): Payload bytes
0 – 7 after IP header. IPv4 options are not parsed so
payload is always taken 20 bytes after the start of the
IPv4 header for non TCP/UDP IPv4 frames.
x
x
OAM_CCM_CNTS_EQ0 Flag indicating if dual-ended loss measurement
counters in CCM frames are used.
This flag is set if the TxFCf, RxFCb, and TxFCb
counters are set to all zeros.
1
x
OAM_Y1731
Set if frame’s EtherType = 0x8902. If set, ETYPE is
overloaded with OAM MEL flags, See ETYPE.
1
x
CUSTOM1
57 bytes payload starting from current frame pointer
position, as controlled by VCAP CLM actions.
Note that if frame_type==ETH, then payload is
retrieved from a position following the Ethernet layer,
for example, after DMAC, SMAC, 0 – 3 VLAN tags,
and EtherType.
456
CUSTOM2
24 bytes payload from frame. Location in frame is
controlled by VCAP CLM actions.
Note that if frame_type==ETH, payload is retrieved
from a position following the Ethernet layer, for
example, after DMAC, SMAC, 0–3 VLAN tags and
EtherType.
192
3.18.2
x
x
x
VCAP IS2 Actions
VCAP IS2 supports only one action, size 196 bits, which applies to all VCAP IS2 keys. The action is
listed in the following table. When programming an action in VCAP IS2, the associated action fields listed
must be programmed in the listed order with the first field in the table starting at bit 0 in the action.
Table 104 • VCAP IS2 Actions
Action Name
Description
Size
IS_INNER_ACL
Set if VCAP IS2 action belongs to ANA_IN_SW pipeline point.
1
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
153
Functional Descriptions
Table 104 • VCAP IS2 Actions (continued)
Action Name
Description
Size
PIPELINE_FORCE If set, use PIPELINE_PT unconditionally and set PIPELINE_ACT = NONE if
_ENA
PIPELINE_PT == NONE. Overrules previous settings of pipeline point.
1
PIPELINE_PT
Pipeline point used if PIPELINE_FORCE_ENA is set:
0: NONE
1: ANA_VRAP
2: ANA_PORT_VOE
3: ANA_CL
4: ANA_CLM
5: ANA_IPT_PROT
6: ANA_OU_MIP
7: ANA_OU_SW
8: ANA_OU_PROT
9: ANA_OU_VOE
10: ANA_MID_PROT
11: ANA_IN_VOE
12: ANA_IN_PROT
13: ANA_IN_SW
14: ANA_IN_MIP
15: ANA_VLAN
16: ANA_DONE
5
HIT_ME_ONCE
If set, the next frame hitting the rule is copied to CPU using CPU_QU_NUM.
CPU_COPY_ENA overrules HIT_ME_ONCE implying that if CPU_COPY_ENA is also
set, all frames hitting the rule are copied to the CPU.
1
INTR_ENA
If set, an interrupt is triggered when this rule is hit
1
CPU_COPY_ENA
If set, frame is copied to CPU using CPU_QU_NUM.
1
CPU_QU_NUM
CPU queue number used when copying to the CPU
3
CPU_DIS
If set, disable extraction to CPU queues from previous forwarding decisions. Action
CPU_COPY_ENA is applied after CPU_DIS.
1
LRN_DIS
If set, autolearning is disallowed.
1
RT_DIS
If set, routing is disallowed.
1
POLICE_ENA
If set, frame is policed by policer pointed to by POLICE_IDX.
Overloading: If cleared, POLICE_IDX can be used to select a new source IP address
from table ANA_ACL::SWAP_SIP when replacing IP addresses. See ACL_RT_MODE.
1
POLICE_IDX
Selects policer index used when policing frames.
5
Overloading: If POLICE_ENA=0, selects source IP address when replacing IP addresses.
IGNORE_PIPELIN
E_CTRL
Ignore ingress pipeline control. This enforces the use of the VCAP IS2 action even when 1
the pipeline control has terminated the frame before VCAP IS2.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
154
Functional Descriptions
Table 104 • VCAP IS2 Actions (continued)
Action Name
Description
Size
DLB_OFFSET
Overloading:
1. logMessageInterval.
If REW_CMD[5] = 1:
For multicast Delay_Resp frames, SWAP_MAC_ENA and DLB_OFFSET encode a new
logMessageInterval:
SWAP_MAC_ENA=0, DLB_OFFSET=0: logMessageInterval = 0
SWAP_MAC_ENA=0, DLB_OFFSET=1: logMessageInterval = 1
...
SWAP_MAC_ENA=0, DLB_OFFSET=7: logMessageInterval = 7
SWAP_MAC_ENA=1, DLB_OFFSET=0: logMessageInterval = –8
SWAP_MAC_ENA=1, DLB_OFFSET=1: logMessageInterval = –7
...
SWAP_MAC_ENA=1, DLB_OFFSET=7: logMessageInterval = –1
3
2. DLB policer index.
If ACL_RT_MODE[3:2] = 1 and ACL_MAC[8:7] = 3, then DLB_OFFSET selects bits 2:0 in
the DLB policer index used by the frame.
LOG_MSG_INT
Controls logMessageInterval when REW_CMD[5] = 1:
3
For multicast Delay_Resp frames, SWAP_MAC_ENA and LOG_MSG_INT encode a new
logMessageInterval:
SWAP_MAC_ENA=0, LOG_MSG_INT=0: logMessageInterval = 0
SWAP_MAC_ENA=0, LOG_MSG_INT=1: logMessageInterval = 1
...
SWAP_MAC_ENA=0, LOG_MSG_INT=7: logMessageInterval = 7
SWAP_MAC_ENA=1, LOG_MSG_INT=0: logMessageInterval = –8
SWAP_MAC_ENA=1, LOG_MSG_INT=1: logMessageInterval = –7
...
SWAP_MAC_ENA=1, LOG_MSG_INT=7: logMessageInterval = –1
MASK_MODE
Controls how PORT_MASK is applied.
3
0: OR_DSTMASK: Or PORT_MASK with destination mask.
1: AND_VLANMASK: And PORT_MASK with VLAN mask.
2: REPLACE_PGID: Replace PGID port mask from MAC table lookup by PORT_MASK.
3: REPLACE_ALL: Use PORT_MASK as final destination set replacing all other port
masks. Note that with REPLACE_ALL, the port mask becomes sticky and cannot be
modified by subsequent processing steps.
4: REDIR_PGID: Redirect using PORT_MASK[10:0] as PGID table index. See
PORT_MASK for extra configuration options.
Note that the port mask becomes sticky and cannot be modified by subsequent
processing steps.
5: OR_PGID_MASK: Or PORT_MASK with PGID port mask from MAC table lookup.
6: VSTAX: Allows control over VSTAX forwarding. Note that the port mask becomes sticky
and cannot be modified by subsequent processing steps.
7: Does not apply.
The CPU port is untouched by MASK_MODE.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
155
Functional Descriptions
Table 104 • VCAP IS2 Actions (continued)
Action Name
Description
PORT_MASK
Port mask applied to the forwarding decision.
55
MASK_MODE=4:
PORT_MASK[52]: SRC_PORT_MASK_ENA. If set, SRC_PORT_MASK is AND’ed with
destination result.
PORT_MASK[51]: AGGR_PORT_MASK_ENA. If set, AGGR_PORT_MASK is AND’ed
with destination result.
PORT_MASK[50]: VLAN_PORT_MASK_ENA. If set, VLAN_PORT_MASK is AND’ed
with destination result.
MASK_MODE=6 (VSTAX):
PORT_MASK[0]: VS2_ENA - Enable use of vstax for forwarding
PORT_MASK[1]: VS2_DIS - Disable use of vstax for forwarding if not VS2_ENA
PORT_MASK[2]: VLAN_IGNORE - Disable Vlan port mask contribution
PORT_MASK[3]: SRC_IGNORE - Disable source port mask contribution
PORT_MASK[4]: AGGR_IGNORE - Disable Aggr port mask contribution
PORT_MASK[5]: VS2_SRC_ENA - Update VSTAX.SRC field (and set
LRN_MODE = LRN_SKIP)
PORT_MASK[6]: VS2_DST_ENA - Update VSTAX.DST and VSTAX.GEN.FWD_MODE
and set VSTAX.GEN.TTL=31, such that egress stack port sets TTL.
PORT_MASK[18:7]: VS2_SRC - Value to be used for VSTAX.SRC
PORT_MASK[29:19]: VS2_DST - Value to be used for VSTAX.DST
PORT_MASK[30]: VS2_GEN_FWD_MODE_ENA update VSTAX.GEN.FWD_MODE
PORT_MASK[31]: VS2_RSV - Reserved
PORT_MASK[34:32]: VS2_FWD_MODE; value to be used for VSTAX.GEN.FWD_MODE
MIRROR_PROBE
Mirroring performed according to configuration of a mirror probe.
0: No mirroring.
1: Mirror probe 0.
2: Mirror probe 1.
3: Mirror probe 2.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
Size
2
156
Functional Descriptions
Table 104 • VCAP IS2 Actions (continued)
Action Name
Description
Size
REW_CMD
REW_CMD[1:0] - PTP command.
0: No command.
1: ONE-STEP update. Update PTP PDU according to ingress and egress port mode
2: TWO-STEP stamping. Send frame untouched, but store ingress and egress time
stamps in the time stamp FIFO.
3: TIME-OF-DAY update. Fill system time-of-day into frame.
8
REW_CMD[3:2] - Delay command:
0: No command.
1: Add configured egress delay for the egress port (REW::PTP_EDLY_CFG).
2: Add configured ingress delay for the ingress port (REW::PTP_IDLY1_CFG).
3: Add configured ingress delay for the ingress port (REW::PTP_IDLY2_CFG).
REW_CMD[5:4] - Sequence number and time stamp command:
0: No command.
1: Fill in sequence number and increment. Sequence number is selected by IFH.TSTAMP.
2: Enable Delay_Req/resp processing. This mode includes updating the
requestReceiptTimestamp with the ingress time stamp.
3: Enable Delay_Req/resp processing. This mode excludes updating the
requestReceiptTimestamp.
Note that if REW_CMD[5] is set, REW_CMD[5:4] is cleared by ANA_ACL before passing
the REW_CMD action to the rewriter.
REW_CMD[6]: If set, set DMAC to incoming frame’s SMAC.
REW_CMD[7]: If set, set SMAC to configured value for the egress port.
REW_CMD is carried to the rewriter in IFH field VSTAX.DST.REW_CMD.
TTL_UPDATE_ENA If set, IPv4 TTL or IPv6 hop limit is decremented.
Overloading:
If ACL_RT_MODE[3]=1 (SWAPPING) and ACL_RT_MODE[2:0]=4, 5, 6, or 7, the IPv4
TTL or IPv6 hop limit is preset to value configured in ANA_ACL::SWAP_IP_CTRL.
1
SAM_SEQ_ENA
If set, ACL_RT_MODE only applies to frames classified as SAM_SEQ.
Overloading:
If ACL_RT_MODE=0x8 (replace DMAC): If set,
ANA_ACL::SWAP_IP_CTRL.DMAC_REPL_OFFSET_VAL controls number of bits in
frame’s DMAC, counting from MSB, to replace with corresponding bits in ACL_MAC.
1
TCP_UDP_ENA
If set, TCP/UDP ports are set to new values: DPORT = MATCH_ID, SPORT =
MATCH_ID_MASK.
1
MATCH_ID
Logical ID for the entry. The MATCH_ID is extracted together with the frame if the frame is 16
forwarded to the CPU (CPU_COPY_ENA). The result is placed in IFH.CL_RSLT.
Overloading:
If TCP_UDP_ENA is set, MATCH_ID defines new DPORT.
MATCH_ID_MASK Mask used by MATCH_ID.
Overloading:
If TCP_UDP_ENA is set, MATCH_ID defines new SPORT.
16
CNT_ID
Counter ID, used per lookup to index the 4K frame counters (ANA_ACL:CNT_TBL).
Multiple VCAP IS2 entries can use the same counter.
12
SWAP_MAC_ENA
Swap MAC addresses.
Overloading:
If REW_CMD[5]=1: For multicast Delay_Resp frames, SWAP_MAC_ENA and
DLB_OFFSET encodes a new logMessageInterval. See DLB_OFFSET.
LOG_MSG_INT encodes a new logMessageInterval. See LOG_MSG_INT.
1
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
157
Functional Descriptions
Table 104 • VCAP IS2 Actions (continued)
Action Name
Description
Size
ACL_RT_MODE
Controls routing updates in ANA_AC and how ACL_MAC is applied:
0: No change.
ACL_RT_MODE[3] = 0 (ROUTING mode):
ACL_RT_MODE[0] = 1: Enable Unicast routing updates in ANA_AC
ACL_RT_MODE[1] = 1: Enable Multicast routing updates in ANA_AC
ACL_RT_MODE[2] = 1: Enable overloading of ACL_MAC field.
4
ACL_RT_MODE[3] = 1 (SWAPPING mode):
ACL_RT_MODE[2:0] encodes a SWAPPING sub-mode:
0: Replace DMAC.
1: Replace SMAC.
2: Swap MAC addresses. Replace SMAC if new SMAC is multicast.
3: Swap MAC addresses if DMAC is unicast. Replace SMAC if DMAC is multicast.
4: Swap MAC addresses. Replace SMAC if new SMAC is multicast. Swap IP addresses.
Replace SIP if new SIP is multicast.
5: Swap MAC addresses if DMAC is unicast. Replace SMAC if DMAC is multicast. Swap
IP addresses if DIP is unicast. Replace SIP if DIP is multicast.
6: Swap IP addresses. Replace SIP if new SIP is multicast.
7: Replace SMAC. Swap IP addresses. Replace SIP if new SIP is multicast.
Note that when replacing a MAC address, the new MAC address is taken from
ACL_MAC. When replacing a SIP, the new SIP is taken from
ANA_ACL::SWAP_SIP[POLICE_IDX].
ACL_MAC
MAC address used to replace either SMAC or DMAC based on ACL_RT_MODE.
Overloading:
ACL_RT_MODE[3:2] = 1.
ACL_MAC[0]: PORT_PT_CTRL_ENA - Overrule PORT_PT_CTRL.
ACL_MAC[6:1]: PORT_PT_CTRL_IDX - into ANA_AC_POL:PORT_PT_CTRL.
ACL_MAC[16]: Enable use of ACL_MAC[26:17] as DLB policer index.
ACL_MAC[26:17]: DLB policer index.
48
ACL_RT_MODE(3) = 1:
MAC address used to replace either SMAC or DMAC based on ACL_RT_MODE.
PTP_DOM_SEL
3.19
PTP domain selector. PTP_DOM_SEL indexes the PTP configuration in
ANA_ACL:PTP_DOM used in Delay_Resp frames. See REW_CMD.
2
Analyzer Access Control Lists
The analyzer access control list (ANA_ACL) block performs the following tasks.
•
•
•
•
•
Controls the VCAP IS2 lookups in terms of key selection, evaluation of range checkers, and control
of specific VCAP IS2 key fields such as IGR_PORT_MASK_SEL and VID.
Generates VCAP IS2 keys and execute the two lookups.
Updates VCAP IS2 statistics based on match results.
Assigns actions from VCAP IS2 matching or default actions when there is no match.
Controls routing-related frame rewrites.
The following sections provides specific information about each of these tasks.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
158
Functional Descriptions
3.19.1
VCAP IS2
Each frame is classified to one of nine overall VCAP IS2 frame types. The frame type determines which
VCAP IS2 key types are applicable and controls which frame data to extract.
Table 105 • VCAP IS2 Frame Types
Frame Type
Condition
IPv6 multicast frame
The Type/Len field is equal to 0x86DD.
The IP version is 6.
The destination IP address is a multicast address (FF00::/8).
Special IPv6 frames:
•IPv6 TCP frame: Next header is TCP (0x6).
•IPv6 UDP frame: Next header is UDP (0x11).
•IPv6 Other frame: Next header is neither TCP nor UDP.
IPv6 unicast frame
The Type/Len field is equal to 0x86DD.
The IP version is 6.
The destination IP address is not a multicast address.
Special IPv6 frames:
•IPv6 TCP frame: Next header is TCP (0x6).
•IPv6 UDP frame: Next header is UDP (0x11).
•IPv6 Other frame: Next header is neither TCP nor UDP
IPv4 multicast frame
The Type/Len field is equal to 0x800.
The IP version is 4.
The destination IP address is a multicast address (224.0.0.0/4).
Special IPv4 frames:
•IPv4 TCP frame: IP protocol is TCP (0x6).
•IPv4 UDP frame: IP protocol is UDP (0x11).
•IPv4 Other frame: IP protocol is neither TCP nor UDP.
IPv4 unicast frame
The Type/Len field is equal to 0x800.
The IP version is 4.
The destination IP address is not a multicast address.
Special IPv4 frames:
•IPv4 TCP frame: IP protocol is TCP (0x6).
•IPv4 UDP frame: IP protocol is UDP (0x11).
•IPv4 Other frame: IP protocol is neither TCP nor UDP.
(R)ARP frame
The Type/Len field is equal to 0x0806 (ARP) or 0x8035 (RARP).
OAM Y.1731 frame
The Type/Len field is equal to 0x8902 (ITU-T Y.1731).
SNAP frame
The Type/Len field is less than 0x600.
The Destination Service Access Point field, DSAP is equal to 0xAA.
The Source Service Access Point field, SSAP is equal to 0xAA.
The Control field is equal to 0x3.
LLC frame
The Type/Len field is less than 0x600
The LLC header does not indicate a SNAP frame.
ETYPE frame
The Type/Len field is greater than or equal to 0x600, and the Type field does not indicate
any of the previously mentioned frame types, that is, ARP, RARP, OAM, IPv4, or IPv6.
Some protocols of interest do not have their own frame type but are included in other mentioned frame
types. For instance, Precision Time Protocol (PTP) frames are handled by VCAP IS2 as either ETYPE
frames, IPv4 frames, or IPv6 frames. The following encapsulations of PTP frames are supported:
•
•
•
PTP over Ethernet: ETYPE frame with Type/Len = 0x88F7.
PTP over UDP over IPv4: IPv4 UDP frame with UDP destination port numbers 319 or 320.
PTP over UDP over IPv6: IPv6 UDP frame with UDP destination port numbers 319 or 320.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
159
Functional Descriptions
Specific PTP fields are contained in eight bytes of payload extracted after either the EtherType for PTP
over Ethernet or in eight bytes of payload after the UDP header for IPv4/IPv6 frames.
3.19.1.1
Port Configuration and Key Selection
This section provides information about special port configurations that control the key generation for
VCAP IS2.
The following table lists the registers associated with port configuration for VCAP IS2.
Table 106 • Port Configuration of VCAP IS2
Register
Description
Replication
ANA_ACL:PORT:VCAP_S2_KEY_SEL
Configuration of the key selection for the VCAP IS2
Per port per lookup
ANA_ACL::VCAP_S2_CFG
Enabling of VCAP IS2 lookups.
Per port per lookup
Each of the two lookups in VCAP IS2 must be enabled before use (VCAP_S2_CFG.SEC_ENA) for a key
to be generated and a match to be used. If a lookup is disabled on a port, frames received by the port are
not matched against rules in VCAP IS2 for that lookup.
Each port controls the key selection for each of the two lookups in VCAP IS2 through the
VCAP_S2_KEY_SEL register. For some frame type (OAM Y.1731, SNAP, LLC, EYTYPE) the key
selection is given as only the MAC_ETYPE key can be used. For others frame types (ARP and IP)
multiple keys can be selected from. The following table lists the applicable key types available for each
frame type listed in Table 105, page 159.
Table 107 • VCAP IS2 Key Selection
Frame Type
Applicable VCAP IS2 keys
IPv6 multicast frames
IP6_VID
IP_7TUPLE
MAC_ETYPE
IPv6 unicast frames
IP_7TUPLE
MAC_ETYPE
IPv4 multicast frames
IP4_VID
IP_7TUPLE
IP4_TCP_UDP
IP4_OTHER
MAC_ETYPE
IPv4 unicast frames
IP_7TUPLE
IP4_TCP_UDP
IP4_OTHER
MAC_ETYPE
(R)ARP frames
ARP
MAC_ETYPE
OAM Y.1731 frames
MAC_ETYPE
SNAP frames
MAC_ETYPE
LLC frames
MAC_ETYPE
ETYPE frames
MAC_ETYPE
Note: The key selection is overruled if VCAP CLM instructs the use of a custom key, where data from the frame
is extracted at a VCAP CLM-selected point. For more information, see VCAP IS2 Custom Keys,
page 161.
For information about VCAP IS2 keys and actions, see VCAP IS2 Keys and Actions, page 147.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
160
Functional Descriptions
3.19.1.2
VCAP IS2 Custom Keys
VCAP IS2 supports two custom keys, CUSTOM_1 and CUSTOM_2. Custom keys extract raw data from
the frame at one selectable location. The custom keys enable matching against protocol fields not
supported by other VCAP IS2 keys. The use of the custom keys must be enabled through a VCAP CLM
FULL action using CUSTOM_ACE_ENA and CUSTOM_ACE_OFFSET.
CUSTOM_1 extracts 57 consecutive bytes of data from the frame and CUSTOM_2 extracts 24
consecutive bytes of data from the frame. The data is extracted at one of four different positions in the
frame. For frames of frame_type ETH (IFH.TYPE_AFTER_POP), the positions are defined as:
•
•
•
•
Link layer. Corresponds to first byte in DMAC.
Link layer payload. Corresponds to first byte in L3, after VLAN tags and EtherType.
Link layer payload plus 20 bytes. Corresponds to first byte in L4 for IPv4 frame.
Link layer payload plus 40 bytes. Corresponds to first byte in L4 for IPv6 frame.
For frames of frame_type CW, the first link layer position is not available. The positions are defined as:
•
•
•
3.19.1.3
Link layer payload. Corresponds to first byte in control word for non-IP frames and first byte in IP
header for IP frames.
Link layer payload plus 20 bytes. Corresponds to first byte in L4 for IPv4 frame.
Link layer payload plus 40 bytes. Corresponds to first byte in L4 for IPv6 frame.
VCAP IS2 Range Checkers
The following table lists the registers associated with configuring VCAP IS2 range checkers.
Table 108 • VCAP IS2 Range Checker Configuration
Register
Description
Replication
ANA_ACL::VCAP_S2_RNG_CTRL
Configuration of the range checker types
Per range
checker
ANA_ACL::VCAP_S2_RNG_VALUE_CFG
Configuration of range start and end points
Per range
checker
ANA_ACL::VCAP_S2_RNG_OFFSET_CFG
Offset into frame when using a range checker based
on selected value from frame
None
Eight global VCAP IS2 range checkers are supported by the IP4_TCP_UDP and IP_7TUPLE keys. All
frames using these keys are compared against the range checkers and a 1-bit range “match/no match”
flag is returned for each range checker. The combined eight match/no match flags are used in the
L4_RNG key field. So, it is possible to include for example ranges of DSCP values and/or ranges of TCP
source port numbers in the ACLs.
Note, VCAP CLM also supports range checkers but they are independent of the VCAP IS2 range
checkers.
The range key is generated for each frame based on extracted frame data and the configuration in
ANA_ACL::VCAP_S2_RNG_CTRL. Each of the eight range checkers can be configured to one of the
following range types:
•
•
•
TCP/UDP destination port range
Input to the range is the frame’s TCP/UDP destination port number.
Range is only applicable to TCP/UDP frames.
TCP/UDP source port range
Input to the range is the frame’s TCP/UDP source port number.
Range is only applicable to TCP/UDP frames.
TCP/UDP source and destination ports range. Range is matched if either source or destination port
is within range.
Input to the range are the frame’s TCP/UDP source and destination port numbers.
Range is only applicable to TCP/UDP frames.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
161
Functional Descriptions
•
•
•
VID range
Input to the range is the classified VID.
Range is applicable to all frames.
DSCP range
Input to the range is the classified DSCP value.
Range is applicable to IPv4 and IPv6 frames.
Selected frame field range
Input to the range is a selected 16-bit wide field from the frame. The field is selected using the offset
value configured in ANA_ACL::VCAP_S2_RNG_OFFSET_CFG. The offset starts at the Type/Len
field in the frame after up to 3 VLAN tags have been skipped. Note that only one selected value can
be configured for all eight range checkers.
Range is applicable to all frames.
Range start points and range end points are configured in ANA_ACL::VCAP_S2_RNG_VALUE_CFG
with both the start point and the end point being included in the range. A range matches if the input value
to the range (for instance the frame’s TCP/UDP destination port) is within the range defined by the start
point and the end point.
3.19.1.4
Miscellaneous VCAP IS2 Key Configurations
The following table lists the registers associated with configuration that control the specific fields in the
VCAP IS2 keys.
Table 109 • Other VCAP IS2 Key Configurations
Register
Description
Replication
ANA_ACL::VCAP_S2_CFG.SEC_ROUTE_
HANDLING_ENA
Enables use of IRLEG VID and ERLEG VID instead of Per port
classified VID.
ANA_ACL:VCAP_S2:VCAP_S2_MISC_CTRL
Configuration of IGR_PORT_MASK_SEL and
IGR_PORT_MASK.
None
By default, the field VID contains the frame’s classified VID for both VCAP IS2 lookups. Routable frames
(determined by ANA_L3) with field L3_RT=1, can be configured
(ANA_ACL::VCAP_S2_CFG.SEC_ROUTE_HANDLING_ENA) to use the IRLEG VID for the first lookup
in VCAP IS2 and ERLEG VID for the second lookup. This enables ACL rules that apply to the ingress
router leg and ACL rules that apply to the egress router leg. The IRLEG VID and ERLEG VID are
provided by ANA_L3.
All VCAP IS2 keys except IP4_VID and IP6_VID contain the field IGR_PORT_MASK_SEL and
IGR_PORT_MASK. For frames received on a front port, IGR_PORT_MASK_SEL is set to 0 and the bit
corresponding to the frame’s physical ingress port number is set in IGR_PORT_MASK. The following
lists some settings for frames received on other interfaces and how this can be configured through
register VCAP_S2_MISC_CTRL:
•
•
•
•
•
Loopback frames:
By default, IGR_PORT_MASK_SEL = 1 and IGR_PORT_MASK has one bit set corresponding to
the physical port which the frame was looped on. Optionally use IGR_PORT_MASK_SEL = 3.
Masqueraded frames:
By default, IGR_PORT_MASK_SEL=0 and IGR_PORT_MASK has one bit set corresponding to the
masquerade port. Optionally, use IGR_PORT_MASK_SEL = 2.
VStaX frames:
By default, frames received with a VStaX header on a front port use IGR_PORT_MASK_SEL = 0.
Optionally, use IGR_PORT_MASK_SEL=3.
Virtual device frames:
By default, IGR_PORT_MASK_SEL=0 and IGR_PORT_MASK has one bit set corresponding to the
original physical ingress port. Optionally use IGR_PORT_MASK_SEL = 3.
CPU injected frames:
By default, IGR_PORT_MASK_SEL = 0 and IGR_PORT_MASK has none bits set. Optionally use
IGR_PORT_MASK_SEL = 3.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
162
Functional Descriptions
For more information about the contents of IGR_PORT_MASK_SEL and IGR_PORT_MASK, see VCAP
IS2 Key Overview, page 148.
3.19.1.5
Processing of VCAP IS2 Actions
VCAP IS2 returns an action for each enabled VCAP IS2 lookup. If the lookup matches an entry in VCAP
IS2 then the associated action is returned. A default action is returned when no entries are matched. The
first VCAP IS2 lookup returns a default action per physical ingress port while the second VCAP IS2
lookup returns a common default action. There is no difference between an action from a match and a
default action.
VCAP IS2 contains 58 default actions that are allocated the following way:
•
•
•
•
0-52: Per ingress port default actions for first lookup.
53, 54: Per CPU port (CPU0 and CPU1) default actions for first lookup.
55, 56: Per virtual device (VD0 and VD1) default actions for first lookup
57: Common default action for second lookup.
Each of the two VCAP IS2 actions (from first and second lookups) can be processed either at the pipeline
point ANA_OU_SW or at pipeline point ANA_IN_SW. This is controlled by VCAP IS2 action
IS_INNER_ACL. The order of processing is given as:
1.
2.
3.
4.
Process first action if the first’s action IS_INNER_ACL is 0.
Process second action if the second’s action IS_INNER_ACL is 0.
Process first action if the first’s action IS_INNER_ACL is 1.
Process second action if the second’s action IS_INNER_ACL is 1.
This implies that the second action can be processed in ANA_OU_SW pipeline point and the first action
can be processed in ANA_IN_SW pipeline point, or vice versa. Both actions can also be placed at the
same pipeline point in which case the first action is processed before the second.
Processing of each action obeys the frame’s current pipeline information (pipeline point and pipeline
action). For instance if the frame has been redirected at pipeline point ANA_CLM then neither of the
VCAP IS2 actions are applied. However, VCAP IS2 action IGNORE_PIPELINE_CTRL can overrule this.
Furthermore, frame processing between pipeline points ANA_OU_SW and ANA_IN_SW such as OAM
filtering or protection switching can influence the processing of the VCAP IS2 actions so that only an
action belonging to pipeline point ANA_OU_SW is processed.
The following table lists how the two VCAP IS2 action are combined when both VCAP IS2 actions are
processed. For most cases, the processing is sequential, meaning that if both actions have settings for
the same (for instance MIRROR_PROBE), the second processing takes precedence. Others are sticky
meaning they cannot be undone by the second processing if already set by the first.
Table 110 • Combining VCAP IS2 Actions
Action name
Combining actions
IS_INNER_ACL
Processed individually for each action.
PIPELINE_FORCE_ENA
Processed individually for each action. Second processing uses the result from the
first processing which can prevent its processing if the pipeline information from first
processing disables the second processing.
PIPELINE_PT
See PIPELINE_FORCE_ENA.
HIT_ME_ONCE
Sticky.
INTR_ENA
Sticky.
CPU_COPY_ENA
Sticky.
CPU_QU_NUM
Sticky (each action can generate a CPU copy and based on configuration in
ANA_AC:PS_COMMON:CPU_CFG.ONE_CPU_COPY_ONLY_MASK, both copies
can be sent to CPU).
CPU_DIS
Processed individually for each action. Second processing may clear CPU copy from
first processing.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
163
Functional Descriptions
Table 110 • Combining VCAP IS2 Actions (continued)
Action name
Combining actions
LRN_DIS
Sticky.
RT_DIS
Sticky.
POLICE_ENA
Sticky.
POLICE_IDX
Second action takes precedence when POLICE_ENA is set.
IGNORE_PIPELINE_CTRL
Processed individually for each action.
LOG_MSG_INT
Second action takes precedence when LOG_MSG_INT > 0.
MASK_MODE
Processed individually for each action. Second processing uses the result from the
first processing. (If the first processing is sticky, the second processing is not applied).
MASK_MODE is sticky for the following values:
3: REPLACE_ALL
4: REDIR_PGID
6: VSTAX
PORT_MASK
See MASK_MODE.
MIRROR_PROBE
Second action takes precedence when MIRROR_PROBE > 0.
REW_CMD
Second action takes precedence same functions are triggered by both actions. If
different functions are used, both are applied.
TTL_UPDATE_ENA
Second action takes precedence when same function is triggered by both actions. If
different functions are used, both are applied.
TCP_UDP_ENA
Second action takes precedence when TCP_UDP_ENA is set.
MATCH_ID
Processed individually for each action. Second processing uses the result from the
first processing.
MATCH_ID_MASK
Processed individually for each action. Second processing uses the result from the
first processing.
CNT_ID
Processed individually for each action. Two counters are updated, one for each
action.
SWAP_MAC_ENA
Sticky.
ACL_RT_MODE
Second action takes precedence when same function is triggered by both actions. If
different functions are used, both are applied.
ACL_MAC
Second action takes precedence when same function is triggered by both actions. If
different functions are used, both are applied.
PTP_DOM_SEL
Second action takes precedence when PTP_DOM_SEL > 0.
3.19.1.6
VCAP IS2 Statistics and Diagnostics
The following table lists the registers associated with VCAP IS2 statistics and diagnostics.
Table 111 • VCAP IS2 Statistics and Diagnostics
Register
Description
Replication
ANA_ACL::SEC_LOOKUP_STICKY
Sticky bits for each key type used in VCAP IS2.
Per lookup
ANA_ACL::CNT
VCAP IS2 match counters. Indexed with VCAP IS2 action
CNT_ID.
4,096
Each key type use in a lookup in VCAP IS2 triggers a sticky bit being set in
ANA_ACL::SEC_LOOKUP_STICKY. A sticky bit is cleared by writing 1 to it.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
164
Functional Descriptions
Each action returned by VCAP IS2 triggers one of 4,096 counters (ANA_ACL::CNT) to be incremented.
This applies to both actions from matches and default actions. The index into the counters is provided by
VCAP IS2 action CNT_ID. The CNT_ID is fully flexible meaning multiple actions can point to the same
counter. The counters are writable so they can be preset to any value. A counter is cleared by writing 0.
3.19.1.7
Routing Statistics
If a routed frame is discarded by a VCAP IS2 rule it is configurable how the frame is counted in terms of
ingress and egress router leg statistics.
If the frame is discarded by the first VCAP IS2 lookup, it is selectable whether to count the frame in the
ingress router leg statistics (ANA_ACL::VCAP_S2_MISC_CTRL.ACL_RT_IGR_RLEG_STAT_MODE).
The frame is never counted by the egress router leg statistics.
If the frame is discarded by the second VCAP IS2 lookup, it is selectable whether to count the frame in
the egress router leg statistics
(ANA_ACL::VCAP_S2_MISC_CTRL.ACL_RT_EGR_RLEG_STAT_MODE). The frame is always
counted by the ingress router leg statistics.
3.19.2
Analyzer Access Control List Frame Rewriting
The ANA_ACL block supports various frame rewrite functions used in routing and PTP.
When rewriting in the ANA_ACL block, ingress mirroring with an exact mirror copy of the incoming frame
is no longer possible, because any rewrites are also reflected in the mirror copy.
3.19.2.1
Address Swapping and Rewriting
VCAP IS2 actions can trigger frame rewrites in the ANA_ACL block with focus on MAC addresses, IP
addresses, TCP/UDP ports as well as IPv4 TTL and IPv6 hop limit.
The following table lists the registers associated with address swapping and rewriting capabilities in
ANA_ACL.
Table 112 • ANA_ACL Address Swapping and Rewriting Registers
Register
Description
Replication
ANA_ACL::SWAP_SIP
IP table with 32 IPv4 addresses or 8 IPv6 addresses. Provides new
source IP address when swapping IP addresses in frame with
multicast destination IP address.
32
ANA_ACL::SWAP_IP_CTRL Controls IPv4 TTL and IPv6 hop limit values. Controls number of bits to None
replace in DMAC.
VCAP IS2 action ACL_RT_MODE can enable the following rewrite modes:
•
•
•
•
•
Replace DMAC. The frame’s DMAC is replaced with the MAC address specified in VCAP IS2 action
ACL_MAC. It is selectable to only replace part of the DMAC (for instance the OUI only). This is
enabled with VCAP IS2 action REW_CMD[9], and the number of bits to replace is set in
ANA_ACL::SWAP_IP_CTRL.DMAC_REPL_OFFSET_VAL.
Replace SMAC. The frame’s SMAC is replaced with the MAC address specificed in VCAP IS2
action ACL_MAC.
Swap MAC addresses and replace SMAC if MC. The frame’s MAC addresses are swapped. If the
new SMAC is a multicast MAC, it is replaced with the MAC address specificed in VCAP IS2 action
ACL_MAC.
Swap MAC addresses if UC else replace SMAC if MC. The frame’s MAC addresses are swapped
if the frame’s DMAC is unicast. Otherwise, the frame’s SMAC is replaced with the MAC address
specificed in VCAP IS2 action ACL_MAC.
Swap MAC and IP addresses and replace SIP and SMAC if MC. The frame’s MAC addresses are
swapped and the frame’s IP addresses are swapped. If the new SMAC is a multicast MAC, it is
replaced with the MAC address specificed in VCAP IS2 action ACL_MAC. If the new SIP is a
multicast, it is replaced with an IP address from the IP address table ANA_ACL::SWAP_SIP.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
165
Functional Descriptions
•
•
•
Swap MAC and IP addresses if UC else replace SIP and SMAC if MC. The frame’s MAC
addresses are swapped if the frame’s DMAC is unicast. Otherwise, the frame’s SMAC is replaced
with the MAC address specificed in VCAP IS2 action ACL_MAC. The frame’s IP addresses are
swapped if the frame’s DIP is unicast. Otherwise, the frame’s SIP is replaced with an IP address
from the IP address table ANA_ACL::SWAP_SIP.
Swap IP addresses and replace SIP if MC. The frame’s IP addresses are swapped. If the new SIP
is a multicast, it is replaced with an IP address from the IP address table ANA_ACL::SWAP_SIP.
Replace SMAC, swap IP addresses, and replace SIP if MC. The frame’s SMAC is replaced with
the MAC address specificed in VCAP IS2 action ACL_MAC. The frame’s IP addresses are swapped.
If the new SIP is a multicast, it is replaced with an IP address from the IP address table
ANA_ACL::SWAP_SIP.
The IP address table (ANA_ACL::SWAP_SIP) used by some of the above mentioned modes is indexed
using VCAP IS2 action POLICE_IDX (VCAP IS2 action POLICE_ENA must be 0). The IP address table
can contain 32 IPv4 addresses or 8 IPv6 addresses.
When swapping IP addresses or replacing the source IP address, it is also possible to preset the IPv4
TTL or the IPv6 hop limit. This is enabled by VCAP IS2 action TTL_UPDATE_ENA. The new TTL value
for IPv4 frames is configured in ANA_ACL::SWAP_IP_CTRL.IP_SWAP_IP4_TTL_VAL and the new hop
limit value for IPv6 frames is configured in ANA_ACL::SWAP_IP_CTRL.IP_SWAP_IP4_TTL_VAL.
IPv4 and IPv6 TCP/UDP frames have the option to replace the source and destination port numbers with
new values. This is enabled through VCAP IS2 action TCP_UDP_ENA and new port numbers are
provided by VCAP IS2 action MATCH_ID and MATCH_ID_MASK.
The IPv4 header checksum is updated whenever required by above mentioned frame rewrites. The UDP
checksum is updated whenever required for IPv6 frames and cleared for IPv4 frames.
3.19.2.2
Routing in ANA_ACL
The following table lists the registers associated with routing capabilities in ANA_ACL.
Table 113 • ANA_ACL Routing Registers
Register
Description
Replication
ANA_ACL::VCAP_S2_MISC_CTRL.ACL_RT_SEL
Enable routing related frame rewrites in
ANA_ACL
None
ANA_ACL::VCAP_S2_MISC_CTRL.ACL_RT_UPDATE Enable use of egress router leg as VSI in
_GEN_IDX_ERLEG_ENA
rewriter.
None
ANA_ACL::VCAP_S2_MISC_CTRL.ACL_RT_UPDATE Enable use of egress VID as VSI in rewriter.
_GEN_IDX_EVID_ENA
None
If PTP and routing is to be supported concurrently, then some routing related frame rewrites must be
done in ANA_ACL instead of in the rewriter. This is enabled in
ANA_ACL::VCAP_S2_MISC_CTRL.ACL_RT_SEL or by setting VCAP IS2 action ACL_RT_MODE.
When enabled, the frame’s DMAC is changed to the next-hop MAC address specificed by ANA_L3 and
the rewriter is informed not to rewrite the DMAC. The following classification results used by the rewriter
are changed when routing in ANA_ACL.
•
•
The frame’s classified VID is set to the egress VID.
The frame’s classified VSI is optionally set to the egress router leg
(ANA_ACL::VCAP_S2_MISC_CTRL.ACL_RT_UPDATE_GEN_IDX_ERLEG_ENA) or the egress
VID (ANA_ACL::VCAP_S2_MISC_CTRL.ACL_RT_UPDATE_GEN_IDX_EVID_ENA)
In addition, ANA_L3 must be setup to change the source MAC address with the address belonging to the
egress router leg (ANA_L3::ROUTING_CFG.RT_SMAC_UPDATE_ENA). The IPv4 TTL or IPv6 hop limit
is still decremented by the rewriter.
3.19.2.3
PTP Delay_Req/Resp Processing
VCAP IS2 actions can trigger PTP Delay_Req/resp processing where an incoming Delay_Req frame is
terminated and a Delay_Resp frame is generated with appropriate PTP updates.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
166
Functional Descriptions
The following table lists the registers associated with PTP processing and rewriting capabilities in
ANA_ACL.
Table 114 • ANA_ACL PTP Processing and Rewriting Registers
Register
Description
Replication
ANA_ACL:PORT:PTP_CFG
PTP time domain configuration and PTP
portNumber configuration used in portIdentity.
Per port
ANA_ACL::PTP_MISC_CTRL
Enable Delay_Req/resp processing.
Enable logMessageInterval update for multicast
Delay_Resp frames.
None
ANA_ACL:PTP_DOM:PTP_CLOCK_ID_MSB
PTP clockIdentity used in portIdentity.
Per PTP
domain
ANA_ACL:PTP_DOM:PTP_CLOCK_ID_LSB
PTP clockIdentity used in portIdentity.
Per PTP
domain
ANA_ACL:PTP_DOM:PTP_SRC_PORT_CFG
PTP portNumber used in portIdentity. Configuration Per PTP
of whether to use fixed portNumber or per-port
domain
portNumber.
ANA_ACL:PTP_DOM:PTP_MISC_CFG
Configuration of flagField with associated mask.
The PTP domain is specified with VCAP IS2 action
PTP_DOM_SEL.
Per PTP
domain
VCAP IS2 action REW_CMD defines the Delay_Req/Resp processing mode where two modes exist:
•
•
Generate Delay_Resp from Delay Req frame and update the receiveTimestamp in the PTP header
with the ingress PTP time stamp. Use the time stamp from the configured time domain
(ANA_ACL:PORT:PTP_CFG.PTP_DOMAIN). This time domain must match the selected time
domain on the ingress port (DEVxx::PTP_CFG.PTP_DOM)
Generate Delay_Resp from Delay Req frame and do not update the receiveTimestamp.
In addition to the VCAP IS2 action, the Delay_Req/Resp processing must also be enabled in ANA_ACL
(ANA_ACL::PTP_MISC_CTRL.PTP_ALLOW_ACL_REW_ENA).
In addition to updating the receiveTimestamp, the following PTP header modifications are done
independently of the Delay_Req/Resp processing mode:
•
•
•
•
messageType. The PTP messageType is set to 0x9 (Delay_Resp)
messageLength. The PTP messageLength is set to 0x54 and the frame is expanded with 10 bytes
to accomodate the requestingPortIdentity. If the frame expands beyond 148 bytes, then the frame is
discarded.
For PTP frames carried over UDP, the UDP length is increased with 10 bytes. It is mandatory that
the original UDP length is 44 bytes. For PTP frames carried over IPv4, the IP total length is
increased with 10 bytes.
flagField. Selected bits in the PTP flagField can be reconfigured using the per-PTP domain
configured flagField and flagField mask (ANA_ACL:PTP_DOM:PTP_MISC_CFG).
The PTP domain is selected using VCAP IS2 action PTP_DOM_SEL.
sourcePortIdentity. The sourcePortIdentity is constructed using a 64-bit clockIdentity and a 16-bit
portNumber. The clockIdentity is configurable per-PTP domain.
By default, the portNumber is set to a per-PTP domain configured value. In addition, it is selectable
to overwrite the six least significant bits with a per-port configured value.
•
•
The PTP domain is selected using VCAP IS2 action PTP_DOM_SEL.
controlField. The PTP controlField is set to 0x3.
logMessageInterval. The PTP logMessageInterval can be specified for multicast frames only with
new values ranging from –8 through 7. The new value is configured using VCAP IS2 actions
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
167
Functional Descriptions
SWAP_MAC_ENA and LOG_MSG_INT.
•
This update can be globally disabled in
ANA_ACL::PTP_MISC_CTRL.PTP_DELAY_REQ_MC_UPD_ENA.
requestingPortIdentity. This fields is set to the incoming frame’s sourcePortIdentity.
For PTP frames carried over UDP, any PTP header modifications trigger the UDP checksum to be
updated for IPv6 frames and to be cleared for IPv4 frames.
In addition to the PTP header modifications, address swapping and rewriting can also be enabled for
PTP frames. For PTP carried over UDP it can be useful to also swap MAC addresses, swap IP
addresses, change UDP port numbers, and preset the IPv4 TTL or IPv6 hop limit.
3.20
Analyzer Layer 2 Forwarding and Learning
The analyzer Layer 2 (ANA_L2) block performs the following tasks:
•
•
•
•
Determining forwarding decisions
Tracking network stations and their MAC addresses through learning and aging
Tracking and setting limits for number station learned per FID/ports
Scanning and updating the MAC table
The analyzer Layer 2 block makes a forwarding decision based on a destination lookup in the MAC table.
The lookup is based on the received Destination MAC address together with either the classified VID for
multicast traffic or the classified FID for unicast traffic. If an entry is found in the MAC table lookup, the
associated entry address is used for selecting forwarding port or ports. A flood forwarding decision is
made if no entry is found and forwarding to unknown destinations is permitted
(ANA_L3:VLAN:VLAN_CFG.VLAN_SEC_FWD_ENA).
The analyzer Layer 2 block performs a source lookup in the MAC table to determine if the source station
is known or unknown by looking at if there is an entry in the MAC table. If a MAC table entry exists, a port
move detection is performed by looking at whether the frame was received at the expected interface
specified. The source check can trigger the following associated actions.
•
•
•
Disabling forwarding from unknown or moved stations
Triggering automated learning
Sending copy to CPU
If the source station is known, the entry AGE_FLAG is cleared to indicate that source associated with the
entry is active. The AGE_FLAG is part of the aging functionality to remove inactive MAC table entries.
For more information, see Automated Aging (AUTOAGE), page 181.
The following subsections further describe the main analyzer Layer 2 blocks.
3.20.1
Analyzer MAC Table
The analyzer Layer 2 block contains a MAC table with 32,768 entries containing information about
stations learned or known by the device. The table is organized as a hash table with four buckets on each
row. Each row is indexed based on a hash value calculated based on the station’s (FID, MAC) pair.
The filtering ID (FID) used is either the FID from the VLAN table if a unicast MAC is looked up or else it is
the classified VID. It is possible to enforce use of FID for multicast (ANA_L3:COMMON:SERVICE_CFG).
MAC table organization is depicted in the following illustration.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
168
Functional Descriptions
Figure 29 • MAC Table Organization
Row 0
MAC Entry
CMAC Table
HASH_KEY (FIX, MAC)
3.20.1.1
ck
et
3
2
Bu
ck
et
Bu
ck
et
Bu
Bu
ck
et
0
1
Row 8191
MAC Entry Table
Each entry in the MAC table contains the fields listed in the following table.
Table 115 • MAC Table Entry
Field
Bits
Description
VLD
1
Entry is valid.
MAC
48
The MAC address of the station. (Part of primary key).
FID
13
VLAN filtering identifier (FID) unicast C-MAC entries. VLAN identifier (VID) for multicast
C-MAC entries. (Part of primary key).
LOCKED
1
Lock the entry as static. Note: Locking an entry will prevent hardware from changing
anything but the AGE_FLAG in the entry.
MIRROR
1
Frames from or to this station are candidate for mirroring.
AGE_FLAG
2
The number of loopbackaging periods that have taken place since the last frame was
received from this station. Incremented by hardware during a CPU SCAN and
AUTOAGE SCAN for the entry configured AGE_INTERVAL.
AGE_INTERVAL
2
Used to select which age timer is associated with the entry.
NXT_LRN_ALL
1
Used to ensure consistent MAC tables in a stack.
CPU_COPY
1
Frames from or to this station are candidate for CPU copy. Used together with CPU_QU
(to specify queue number).
CPU_QU
3
Used together with CPU_COPY.
SRC_KILL_FWD
1
Frames from this station will not be forwarded. This flag is not used for destination
lookups.
VLAN_IGNORE
1
Used for ignoring the VLAN_PORT_MASK contribution from the VLAN table when
forwarding frames to this station. Can optionally be used for source port ignore
(ANA_L2::FWD_CFG.FILTER_MODE_SEL).
ADDR
12
Stored entry address used for forwarding and port move detection. The field is encoded
according to ADDR_TYPE.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
169
Functional Descriptions
Table 115 • MAC Table Entry (continued)
Field
Bits
Description
ADDR_TYPE
3
This field encodes how to interpret the ADDR field.
Encoded as:
ADDR_TYPE= UPSID_PN(0): Unicast entry address. Used to associate the entry with
a unique {UPSID, UPSPN} port.
ADDR(9:5) = UPSID
ADDR(4:0) = UPSPN
ADDR_TYPE=GCPU_UPS(1): CPU management entry address. Used to associate the
entry with a unique global CPU port or internal port.
ADDR(9:5) = UPSID
ADDR(11) = 0:
ADDR(3:0) = CPU port number.
ADDR(11) = 1:
ADDR(3:0) = 0xe: Internal port number.
ADDR(3:0) = 0xf: Local lookup at destination unit (UPSID).
ADDR_TYPE=GLAG(2): Unicast GLAG address. Used to associate the entry with a
global aggregated port.
ADDR = GLAGID.
ADDR_TYPE=MC_IDX(3): Multicast entry address. Used to associate the entry with an
entry in the PGID table. Specifies forwarding to the ports found in the PGID table entry
indexed by mc_idx.
ADDR = mc_idx.
3.20.1.2
CAM Row
Under some circumstances, it might be necessary to store more entries than possible on a MAC table
row, in which case entries are continuously changed or automatically updated.
To reduce this issue, one additional MAC table row (named CAM row) exist with entries that can be used
to extend any hash chain, and thereby reduce the probability for hash depletion where all the buckets on
a MAC table row are used. These entries on the CAM row can be used as any other MAC table entries.
CAM row usage is controlled separately (by ANA_L2::LRN_CFG.AUTO_LRN_USE_MAC_CAM_ENA,
ANA_L2::LRN_CFG.CPU_LRN_USE_MAC_CAM_ENA and
ANA_L2::LRN_CFG.LRN_MOVE_CAM_ENTRY_BACK).
3.20.2
MAC Table Updates
Entries in the MAC table are added, deleted, or updated by the following methods.
•
•
•
3.20.3
Automatic (hardware-based) learning of source MAC addresses; that is, inserting new (MAC, FID)
pairs in the MAC table
CPU access to MAC table (for example, CPU-based learning and table maintenance)
Automated age scan.
CPU Access to MAC Table
This section describes CPU access to the MAC table. The following table lists the applicable registers.
Table 116 • MAC Table Access Registers
Target::Register.Field
Description
Replication
LRN:: COMMON_ACCESS_CTRL Controls CSR access to MAC table.
1
LRN::MAC_ACCESS_CFG_0
1
Configures MAC (most significant bits) and FID for MAC table
entries.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
170
Functional Descriptions
Table 116 • MAC Table Access Registers (continued)
Target::Register.Field
Description
Replication
LRN::MAC_ACCESS_CFG_1
Configures MAC address (Least significant bits) for MAC table
entries and FID.
1
LRN::MAC_ACCESS_CFG_2
Configures the following MAC entry fields:
ADDR
ADDR_TYPE
SRC_KILL_FWD
NXT_LRN_ALL
CPU_COPY
VLAN_IGNORE
AFE_FLAG
AGE_INTERNAL
MIRROR
LOCKED
VLD
1
LRN::EVENT_STICKY
Sticky status for access performed.
1
LRN::SCAN_NEXT_CFG
MAC table scan filter controls.
1
LRN::SCAN_NEXT_CFG_1
MAC table port move handles when performing MAC table SCAN. 1
ANA_L2::SCAN_FID_CTRL
Controls use of additional FIDs when doing scan.
1
ANA_L2::SCAN_FID_CFG
Configures additional VID/FID filters during scan if enabled in
ANA_L2::SCAN_FID_CTRL.
16
LRN::SCAN_LAST_ROW_CFG
Configures a last row applicable for scan.
1
LRN::SCAN_NEXT_CNT
MAC table status when performing MAC table SCAN.
1
LRN::LATEST_POS_STATUS
Holds the latest CPU accessed MAC table location after a
CPU_ACCESS_CMD has finished.
1
CPU access to the MAC table is performed by an indirect command-based interface where a number of
fields are configured (in LRN::MAC_TABLE_ACCESS_CFG_*) followed by specifying the command (in
LRN::COMMON_ACCESS_CTRL.CPU_ACCESS_CMD). The access is initiated by a shot bit that is
cleared upon completion of the command
(LRN::COMMON_ACCESS_CTRL.MAC_TABLE_ACCESS_SHOT). It is possible to trigger CPU
interrupt upon completion (ANA_L2:COMMON:INTR.LRN_ACCESS_COMPLETE_INTR).
The following table lists the types of access possible.
Table 117 • MAC Table Access Commands
Command
Purpose
Use
Learn
Insert/learn new entry in MAC Configure MAC and FID of the new entry in
table.
LRN::MAC_ACCESS_CFG_0 and LRN::MAC_ACCESS_CFG_1.
Position given by HASH(MAC, Configure entry fields in LRN::MAC_ACCESS_CFG_2.
FID).
Status of operation returned in:
LRN::EVENT_STICKY.CPU_LRN_REFRESH_STICKY,
LRN::EVENT_STICKY.CPU_LRN_INSERT_STICKY,
LRN::EVENT_STICKY.CPU_LRN_REPLACE_STICKY,
LRN::EVENT_STICKY.CPU_LRN_REPLACE_FAILED_STICKY,
LRN::EVENT_STICKY.CPU_LRN_FAILED_STICKY, and
LRN::EVENT_STICKY.LRN_MOVE_STICKY
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
171
Functional Descriptions
Table 117 • MAC Table Access Commands (continued)
Command
Purpose
Use
Unlearn/Forget
Delete/unlearn entry in MAC
table given by (MAC, FID).
Configure MAC and FID of the entry to be unlearned in
LRN::MAC_ACCESS_CFG_0 and LRN::MAC_ACCESS_CFG_1.
Position given by HASH(MAC, Status of operation returned in:
FID).
LRN::EVENT_STICKY.CPU_UNLEARN_STICKY and
LRN::EVENT_STICKY.CPU_UNLEARN_FAILED_STICKY.
Lookup
Lookup entry in MAC table
given by (MAC, FID).
Configure MAC and FID of the entry to be looked up in
LRN::MAC_ACCESS_CFG_0 and LRN::MAC_ACCESS_CFG_1.
Position given by HASH(MAC, Status of lookup operation returned in:
FID)
LRN::EVENT_STICKY.CPU_LOOKUP_STICKY and
LRN::EVENT_STICKY.CPU_LOOKUP_FAILED_STICKY
Entry fields are returned in LRN::MAC_ACCESS_CFG_2 if lookup
succeeded.
Read direct
Read entry in MAC table
indexed by (row, column)
Configure the index of the entry to read in
LRN::COMMON_ACCESS_CTRL.CPU_ACCESS_DIRECT_ROW
, LRN::COMMON_ACCESS_CTRL.CPU_ACCESS_DIRECT_COL
and
LRN::COMMON_ACCESS_CTRL.CPU_ACCESS_DIRECT_TYPE
Status of read operation returned in
LRN::EVENT_STICKY.CPU_READ_DIRECT_STICKY
Entry fields are returned in LRN::MAC_ACCESS_CFG_0,
LRN::MAC_ACCESS_CFG_1 and LRN::MAC_ACCESS_CFG_2 if
read succeeded.
Write direct
Write entry in MAC table
indexed by (row, column)
Configure the index of the entry to write in
LRN::COMMON_ACCESS_CTRL.CPU_ACCESS_DIRECT_ROW
, LRN::COMMON_ACCESS_CTRL.CPU_ACCESS_DIRECT_COL
and
LRN::COMMON_ACCESS_CTRL.CPU_ACCESS_DIRECT_TYPE
Configure entry fields in LRN::MAC_ACCESS_CFG_0,
LRN::MAC_ACCESS_CFG_1 and LRN::MAC_ACCESS_CFG_2
Status of write operation returned in
LRN::EVENT_STICKY.CPU_WRITE_DIRECT_STICKY
Scan
Find next/Find all
Configure the starting row for the scan in:
LRN::COMMON_ACCESS_CTRL.CPU_ACCESS_DIRECT_ROW
Searches through the MAC
, LRN::COMMON_ACCESS_CTRL.CPU_ACCESS_DIRECT_COL
table and either stops at the
and
first row with entries matching LRN::COMMON_ACCESS_CTRL.CPU_ACCESS_DIRECT_TYPE
the specified filter conditions
or perform the specified
Configure an ending row for the scan (if searching through the
actions on all entries matching complete table is not required):
the specified filter conditions. LRN::SCAN_LAST_ROW_CFG.SCAN_LAST_ROW
For information about search filters and corresponding actions, see
SCAN Command, page 174.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
172
Functional Descriptions
Table 117 • MAC Table Access Commands (continued)
Command
Purpose
Use
Find smallest
Get the smallest entry in the
Configure MAC and FID of the starting point for the search in
MAC table numerically larger LRN::MAC_ACCESS_CFG_0 and LRN::MAC_ACCESS_CFG_1.
than the specified (FID, MAC).
Configure search filters to be used during find smallest:
FID and MAC are evaluated as Use
a 61 bit number with the FID
LRN::SCAN_NEXT_CFG.SCAN_NEXT_IGNORE_LOCKED_ENA
being most significant.
to only search among entries with
LRN::MAC_ACCESS_CFG_2.MAC_ENTRY_LOCKED cleared.
Use LRN::SCAN_NEXT_CFG.FID_FILTER_ENA to only search
among entries with the VID/FID specified in
LRN::MAC_ACCESS_CFG_0.MAC_ENTRY_FID.
Use LRN::SCAN_NEXT_CFG.ADDR_FILTER_ENA to only search
among entries with the address specified in
LRN::MAC_ACCESS_CFG_2.MAC_ENTRY_ADDR and
LRN::MAC_ACCESS_CFG_2.MAC_ENTRY_ADDR_TYPE
Clear all
Initialize the table
3.20.3.1
Clears the entire table.
Adding a Unicast Entry
Use the following steps to add a unicast entry to the MAC table using the CPU interface.
1.
2.
3.
4.
5.
6.
3.20.3.2
Configure the entry MAC address: LRN::MAC_ACCESS_CFG_0.MAC_ENTRY_MAC_MSB LRN::MAC_ACCESS_CFG_1.MAC_ENTRY_MAC_LSB < 32 LS MAC bit >
Configure the VLAN FID:
LRN::MAC_ACCESS_CFG_0.MAC_ENTRY_FID
Configure the UPSID/UPSPN value:
LRN::MAC_ACCESS_CFG_2.MAC_ENTRY_ADDR_TYPE 0 (=UPSID)
LRN::MAC_ACCESS_CFG_2.MAC_ENTRY_ADDR
Make the entry valid: LRN::MAC_ACCESS_CFG_2.MAC_ENTRY_VLD 1
Perform access:
LRN::COMMON_ACCESS_CTRL.CPU_ACCESS_CMD 0 (=LEARN)
LRN::COMMON_ACCESS_CTRL.MAC_TABLE_ACCESS_SHOT 1
Verify that access succeeded: LRN::COMMON_ACCESS_CTRL.MAC_TABLE_ACCESS_SHOT ==
0? LRN::EVENT_STICKY.CPU_LRN_INSERT_STICKY==1?
Adding Multicast Entry with Destination Set in PGID Table
Use the following steps to add Layer 2 multicast entries to the MAC table using the CPU interface.
1.
2.
3.
4.
5.
6.
7.
Configure the entry MAC address: LRN::MAC_ACCESS_CFG_0.MAC_ENTRY_MAC_MSB LRN::MAC_ACCESS_CFG_1.MAC_ENTRY_MAC_LSB < 32 LSB MAC bits >
Configure the VLAN ID:
LRN::MAC_ACCESS_CFG_0.MAC_ENTRY_FID
Configure the PGID pointer:
LRN::MAC_ACCESS_CFG_2.MAC_ENTRY_ADDR_TYPE 3 (=MC_IDX)
LRN::MAC_ACCESS_CFG_2.MAC_ENTRY_ADDR
Lock the entry (not subject to aging and automatic removal):
LRN::MAC_ACCESS_CFG_2.MAC_ENTRY_LOCKED 1
Make the entry valid:
LRN::MAC_ACCESS_CFG_2.MAC_ENTRY_VLD 1
Perform access:
LRN::COMMON_ACCESS_CTRL.CPU_ACCESS_CMD 0 (=LEARN)
LRN::COMMON_ACCESS_CTRL.MAC_TABLE_ACCESS_SHOT 1
Verify that access succeeded: LRN::COMMON_ACCESS_CTRL.MAC_TABLE_ACCESS_SHOT ==
0? LRN::EVENT_STICKY.CPU_LRN_INSERT_STICKY==1?
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
173
Functional Descriptions
3.20.4
SCAN Command
The SCAN command easily performs table management, such as port flushing, CPU-based aging, and
port moves.
Scan can be configured with a variety of filters and modifiers that allows the CPU to easily identify and
optionally modify entries matching the configured filter conditions.
The scan operates by running through all entries and whenever entries are found with matching
conditions, the scan either stops with a status of the matching location (for example, a “find next”
operation) or performs the configured modification actions for all entries (for example, “scan all”
operation).
When the scan runs as “find next”, the scan commands are performed for finding the next matching
entry. In this case it is possible to specify a starting row for a scan (
LRN::COMMON_ACCESS_CTRL.CPU_ACCESS_DIRECT_ROW and
LRN::COMMON_ACCESS_CTRL.CPU_ACCESS_DIRECT_TYPE).
Whenever the scan stops with a matching entry, the CPU can process the entry and then sets the
starting row to the row following the matching row and, issue another scan command. This can then be
repeated until all entries have been scanned.
SCAN is started by setting LRN::COMMON_ACCESS_CTRL.CPU_ACCESS_CMD 5 (=SCAN) and
setting the shot bit LRN::COMMON_ACCESS_CTRL.MAC_TABLE_ACCESS_SHOT
SCAN is completed when the shot bit is cleared in
LRN::COMMON_ACCESS_CTRL.MAC_TABLE_ACCESS_SHOT.
The following table lists the supported SCAN filters.
Table 118 • Scan Filters
Filter Type
Target::Register.Field
Description
FID filter
LRN::SCAN_NEXT_CFG.FID_FILTER_ENA
LRN::MAC_ACCESS_CFG_0.MAC_ENTRY_FID
ANA_L2::SCAN_FID_CTRL
ANA_L2::SCAN_FID_CFG
Finds entries with a specific
VID/FID.
Port or Address filter
LRN::SCAN_NEXT_CFG.ADDR_FILTER_ENA,
LRN::MAC_ACCESS_CFG_2.MAC_ENTRY_ADDR,
LRN::MAC_ACCESS_CFG_2.MAC_ENTRY_ADDR_TY
PE
LRN::SCAN_NEXT_CFG_1.SCAN_ENTRY_ADDR_MA
SK
Finds entries with a specific
ADDR_TYPE and ADDR. Note
that this can be combined with
ADDR wildcards; for example, to
find all entries related with a given
ADDR_TYPE, and so on.
Automatic age scan
port filter
LRN::SCAN_NEXT_CFG.SCAN_USE_PORT_FILTER_E Configures a port filter used for
NA ANA_L2::FILTER_OTHER_CTRL
defining which ports are applicable
ANA_L2::FILTER_LOCAL_CTRL
for automatic aging.
Non-locked only filter
LRN::SCAN_NEXT_CFG.SCAN_NEXT_IGNORE_LOCK Finds non locked entries.
ED_ENA
Aged only filter
LRN::SCAN_NEXT_CFG.SCAN_NEXT_AGED_ONLY_E Finds only aged entries, that is,
NA
AGE_FLAG equal to maximum
(configured in
ANA_L2::LRN_CFG.AGE_SIZE).
AGE_INTERVAL filter
LRN::SCAN_NEXT_CFG.SCAN_AGE_INTERVAL_MAS Finds entries with a specific
AGE_INTERVAL.
K
AGE_FLAG filter
LRN::SCAN_NEXT_CFG.SCAN_AGE_FILTER_SEL
MAC_ACCESS_CFG_2.MAC_ENTRY_AGE_FLAG
NXT_LRN_ALL filter
LRN::SCAN_NEXT_CFG.NXT_LRN_ALL_FILTER_ENA Finds only entries with a specific
MAC_ACCESS_CFG_2. MAC_ENTRY_NXT_LRN_ALL value.
Finds only entries with a specific
value.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
174
Functional Descriptions
Table 118 • Scan Filters (continued)
Filter Type
Target::Register.Field
Description
Ignore locked filter
LRN::SCAN_NEXT_CFG.SCAN_NEXT_IGNORE_LOCK Finds all or only non locked
ED_ENA
entries.
Aged only filter
LRN::SCAN_NEXT_CFG.SCAN_NEXT_AGED_ONLY_E Finds all or only aged entries
NA
(AGE_FLAG != 0).
The following table lists the available SCAN related actions.
Table 119 • Scan Modification Actions
Action Type
Target::Register.Field
Description
Scan next until
found
LRN::SCAN_NEXT_CFG.SCAN_NEXT_UNTIL_FOUND_ENA
Controls if scan stops when
finding an entry or scans
through all entries.
Update
AGE_FLAG
LRN::SCAN_NEXT_CFG.SCAN_AGE_FLAG_UPDATE_SEL
Updates AGE_FLAG for found
entries.
See LRN::SCAN_NEXT_CFG.
Update
LRN::SCAN_NEXT_CFG.SCAN_NXT_LRN_ALL_UPDATE_SEL Update sNXT_LRN_ALL for
NXT_LRN_ALL
found entries.
See LRN::SCAN_NEXT_CFG.
Change
address
(MOVE)
LRN::SCAN_NEXT_CFG.SCAN_NEXT_MOVE_FOUND_ENA
LRN::SCAN_NEXT_CFG_1.PORT_MOVE_NEW_ADDR
LRN::SCAN_NEXT_CFG_1.SCAN_ENTRY_ADDR_MASK
Updates address for found
entries.
Remove
LRN::SCAN_NEXT_CFG.SCAN_NEXT_REMOVE_FOUND_ENA Removes found entries.
CPU age scan
LRN::SCAN_NEXT_CFG.SCAN_NEXT_INC_AGE_BITS_ENA
Performs CPU based age scan.
Aged entries. For example,
entries with AGE_FLAG equal to
maximum (configured in
ANA_L2::LRN_CFG.AGE_SIZE)
are removed and Non aged
entries, such as entries with
AGE_FLAG less than maximum,
gets the AGE_FLAG
incremented. Automatic
Learning, page 179.
The following SCAN status is available:
•
•
•
•
3.20.4.1
Match scan result for the last matching row is reported
(LRN::LATEST_POS_STATUS.SCAN_NEXT_STATUS).
Number of entries found during the scan found (LRN::SCAN_NEXT_CNT.SCAN_NEXT_CNT).
Scan remove is reported via the sticky event (LRN::EVENT_STICKY.SCAN_REMOVED_STICKY)
Scan match found is reported via the sticky event
(LRN::EVENT_STICKY.ROW_WITH_SCAN_ENTRY_STICKY).
Initiating a Port Move for a Specific FID
The following example initiates a port move for specific FID.
•
•
Move found entries:
Set LRN::SCAN_NEXT_CFG.SCAN_NEXT_MOVE_FOUND_ENA = 1.
Specify the FID filter:
Set LRN::SCAN_NEXT_CFG.FID_FILTER_ENA = 1.
Set LRN::MAC_ACCESS_CFG_0.MAC_ENTRY_FID = .
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
175
Functional Descriptions
•
•
•
•
•
3.20.5
Specify port filter:
Set LRN::SCAN_NEXT_CFG.ADDR_FILTER_ENA = 1.
Set LRN::MAC_ACCESS_CFG_2.MAC_ENTRY_ADDR_TYPE = 0 to specify address type
UPSID_PN.
Set LRN::MAC_ACCESS_CFG_2.MAC_ENTRY_ADDR = to specify UPSID and
UPSPN.
Specify the new address:
Set LRN::SCAN_NEXT_CFG_1.PORT_MOVE_NEW_ADDR =
Set LRN::SCAN_NEXT_CFG_1.SCAN_ENTRY_ADDR_MASK = all ones.
Scan through all rows by starting at row 0:
Set LRN::COMMON_ACCESS_CTRL.CPU_ACCESS_DIRECT_ROW = 0.
Set LRN::COMMON_ACCESS_CTRL.CPU_ACCESS_DIRECT_TYPE = 0.
Issue SCAN command:
Set LRN::COMMON_ACCESS_CTRL.CPU_ACCESS_CMD = 5.
Set LRN::COMMON_ACCESS_CTRL.MAC_TABLE_ACCESS_SHOT = 1.
Wait until LRN::COMMON_ACCESS_CTRL.MAC_TABLE_ACCESS_SHOT is cleared.
Forwarding Lookups
This section describes forwarding handling. The following table lists the applicable registers.
Table 120 • Forwarding Registers
3.20.5.1
Target::Register.Field
Description
Replication
ANA_L2:COMMON:FWD_CFG
Configures common forwarding options
1
DMAC-Based Forwarding
The analyzer performs destination lookup in the MAC table to determine if the destination MAC address
is known or unknown.
•
•
If the destination is unknown, a flood forwarding decision is made if forwarding from unknown
sources is allowed (ANA_L3:VLAN:VLAN_CFG.VLAN_SEC_FWD_ENA). The associated flood
masks are located in the PGID table.
If the destination address is known, the associated ADDR_TYPE and ADDR stored in the
destination entry is used to find the destination port or ports in the PGID table.
Flooded traffic can be made available for mirroring
(ANA_L2:COMMON:FWD_CFG.FLOOD_MIRROR_ENA) and CPU copying
(ANA_L2:COMMON:FWD_CFG.FLOOD_CPU_COPY_ENA
ANA_L2:COMMON:FWD_CFG.CPU_DMAC_QU).
Traffic with known DMAC and VLAN_IGNORE set
LRN:COMMON:MAC_ACCESS_CFG_2.MAC_ENTRY_VLAN_IGNORE for CPU learned frames or
LRN:COMMON:AUTO_LRN_CFG.AUTO_LRN_IGNORE_VLAN for auto learned entries) and optionally
also flooded traffic (when ANA_L2:COMMON:FWD_CFG.FLOOD_IGNORE_VLAN_ENA set) can be
configured to ignore VLAN port mask or source port mask
(ANA_L2:COMMON:FWD_CFG.FILTER_MODE_SEL).
The DMAC lookup of the received {DMAC, EFID} in the MAC table is shown in the following illustration.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
176
Functional Descriptions
Figure 30 • DMAC Lookup
DMAC MAC lookup
performed
# MAC entry found?
mac_entry.vld=1?
# Allow VLAN flooding?
req.vlan_flood_dis==1?
false
true
false
# Use info from MAC entry
req.dst_addr_type := mac_entry.addr_type
req.dst_addr := mac_entry.addr
vlan_ignore := mac_entry.vlan_ignore
req.dmac_mirror := mac_entry.mirror
# Use flood configuration
req.flood := true
vlan_ignore :=
ANA_L2::FWD_CFG.FLOOD_IGNORE_VLAN_ENA
req.dmac_mirror :=
ANA_L2::FWD_CFG.FLOOD_MIRROR_ENA
# CPU copy?
ANA_L2::FWD_CFG.CPU_DMAC_COPY_ENA &&
mac_entry.cpu_copy?
req.l2_fwd := 0
req.vlan_mask := 0
true
# CPU copy?
ANA_L2::FWD_CFG.FLOOD_CPU_COPY_ENA?
true
true
false
req.cpu_dest_set( ANA_L2::FWD_CFG.CPU_DMAC_QU) :=
1
req.cpu_dest_set(mac_entry.cpu_qu) := 1
false
vlan_ignore?
true
# VLAN ignore filter mode
ANA_L2:COMMON:FWD_CFG.FILTER_MODE_SEL?
false
true
req.ignore_src_mask := true
req.vlan_mask := ”ALL_ONES”
false
DMAC handling done
3.20.6
Source Check and Automated Learning
This section describes hardware (or automated) learning related to source checking. The following table
lists the applicable registers.
Table 121 • Hardware-Based Learning
Target::Register.Field
Description
Replication
ANA_L2::AUTO_LRN_CFG
ANA_L2::AUTO_LRN_CFG1
Configures automatic learning per port
1
ANA_L2::LRN_SECUR_CFG
ANA_L2::LRN_SECUR_CFG1
Configures secure forwarding per port
1
ANA_L2::LRN_SECUR_LOCKED_CFG Configures secure forwarding for static locked
ANA_L2::LRN_SECUR_LOCKED_CFG1 entries per port.
1
ANA_L2::LRN_COPY_CFG
ANA_L2::LRN_COPY_CFG1
Configures CPU copy of learn frames per port.
1
ANA_L2::MOVELOG_STICKY
ANA_L2::MOVELOG_STICKY1
Identifies ports with moved stations.
1
ANA_L2::LRN_CFG
Configures common learning properties.
1
ANA_L3:VLAN:VLAN_CFG.VLAN_FID
Configures filtering identifier (FID) to be used for
learning.
Per VLAN
LRN::AUTO_LRN_CFG
Configures automatic learning options.
1
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
177
Functional Descriptions
Table 121 • Hardware-Based Learning (continued)
Target::Register.Field
Description
Replication
LRN::EVENT_STICKY
Signal various sticky learning events.
1
ANA_L2:PORT_LIMIT:PORT_LIMIT_
CTRL
Controls automatic learn limits per logical port and
GLAG.
per port and GLAG
(85 instances)
ANA_L2:PORT_LIMIT:PORT_LIMIT_
STATUS
Status for port limits.
per port and GLAG
(85 instances)
ANA_L2:LRN_LIMIT:FID_LIMIT_CTRL
Controls automatic learn limits per FID.
per FID (5,120
instances)
ANA_L2:LRN_LIMIT:FID_LIMIT_
STATUS
Status for FID limits.
per FID (5,120
instances)
The devices learn addresses from each received frame’s SMAC field, so that subsequently forwarded
frames whose destination addresses have been learned can be used to restrict transmission to the port
or ports necessary to reach their destination.
The analyzer performs source lookup of the received {SMAC, IFID} in the MAC table to determine if the
source station is known or unknown. For more information, see Figure 31, page 179. If the source station
is known, a port move detection is performed by checking that the frame was received at the expected
port as specified by the ADDR_TYPE and ADDR stored in the source entry. The expected port can be a
logical port (represented as UPSID, UPSPN) or a global aggregated port (represented as GLAGID).
Failing source checks can trigger a number of associated actions:
•
•
•
•
Secure forwarding. Disable forwarding from unknown or moved stations. This action can be
triggered by two configurations:
VLAN-based Secure forwarding controlled per VLAN
(ANA_L3:VLAN:VLAN_CFG.VLAN_SEC_FWD_ENA).
Port-based secure forwarding controlled per port (ANA_L2::LRN_SECUR_CFG).
Secure forwarding from locked entries. Disable forwarding from known but moved stations with
locked MAC table entry (ANA_L2:COMMON:LRN_SECUR_LOCKED_CFG).
Automatic learning enabled per port (ANA_L2::AUTO_LRN_CFG). Automatic learning of traffic
received from an unknown source station will cause the MAC table to be updated with a new entry.
Traffic received from a known source station with changed port will cause the known MAC table
entry ADDR_TYPE and ADDR to be updated.
CPU copy enabled per port (ANA_L2::LRN_COPY_CFG and ANA_L2::LRN_CFG.CPU_LRN_QU).
A learn copy is sent to CPU.
These actions are controlled independently. In other words, it is possible to send a CPU copy as well as
disable normal forwarding.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
178
Functional Descriptions
Figure 31 • Source Check
Source MAC lookup performed
# MAC entry found?
mac_entry.vld=1?
false
# Create MAC entry
false
mac_entry.addr_type := src_addr.type
mac_entry.addr := src_addr.addr
true
# Port move detection?
mac_entry.addr_type == src_addr.type &&
mac_entry.addr == src_addr.addr?
# CPU copy based on source lookup?
mac_entry.cpu_copy &&
ANA_L2::LRN_CFG.CPU_SMAC_COPY_ENA?
# Automatic learning?
ANA_L2::AUTO_LRN_CFG[req.port_num]==1?
true
false
req.cpu_dest_set(mac_entry.cpu_qu) := 1
# Secure VLAN forwarding?
req.vlan_sec_fwd_ena==1?
false
true
Put mac_entry into auto LRN queue
true
false
# Secure port forwarding?
ANA_L2::LRN_SECUR_CFG[req.port_num]==1?
true
req.l2_fwd := 0
req.vlan_mask := 0
true
req.cpu_dest_set(ANA_L2::LRN_CFG.C
PU_LRN_QU) := 1
false
# CPU copy of learn frames?
ANA_L2::LRN_COPY_CFG[req.port_num]==1?
false
Learn handling done
The source lookup is also used to clear an Age flag (used as activity indication) in the MAC table to allow
inactive MAC table entries to be pruned.
Port move detection is not performed for locked MAC table entries unless enabled
(ANA_L2::LRN_CFG.LOCKED_PORTMOVE_DETECT_ENA).
Frames failing locked port move detection can be copied to CPU queue
(ANA_L2::LRN_CFG.CPU_LRN_QU and ANA_L2::LRN_CFG.LOCKED_PORTMOVE_COPY_ENA).
3.20.6.1
Automatic Learning
The devices can automatically add or update entries in the MAC table. New entries added by automatic
learning are formatted as follows.
•
•
•
•
•
•
•
•
•
VLD is set
MAC is set to the frame’s SMAC address
FID set to the frame’s REQ.FID
ADDR_TYPE, ADDR is set to:
UPSID_PN if received on a non aggregated port
GLAG if received on a global aggregated port
MAC_CPU_COPY (LRN::AUTO_LRN_CFG.AUTO_LRN_CPU_COPY)
MAC_CPU_QU (LRN::AUTO_LRN_CFG.AUTO_LRN_CPU_QU)
SRC_KILL (LRN::AUTO_LRN_CFG.AUTO_LRN_SRC_KILL_FWD)
IGNORE_VLAN (LRN::AUTO_LRN_CFG.AUTO_LRN_IGNORE_VLAN)
MIRROR (LRN::AUTO_LRN_CFG.AUTO_LRN_MIRROR)
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
179
Functional Descriptions
•
•
AGE_INTERVAL (LRN::AUTO_LRN_CFG.AUTO_AGE_INTERVAL)
All other fields are cleared
When a frame is received from a known station, that is, the MAC table already contains an entry for the
received frame’s (SMAC, VID/FID), the analyzer clears the AGED_FLAG for unlocked entries (LOCKED
flag cleared) and optionally, locked entries (ANA_L2:COMMON:LRN_CFG.AGE_LOCKED_ENA). A
cleared AGE_FLAG implies that the station is active. For more information, Automated Aging
(AUTOAGE), page 181.
For unlocked entries, ADDR_TYPE and ADDR fields are compared against the following:
•
•
UPSID_PN if received on a non aggregated port
GLAG if received on a global aggregated port
If there is a difference, the source entry ADDR_TYPE and ADDR is updated, which implies the station
has moved to a new port.
Source check for entries stored with ADDR_TYPE=MC_IDX (=3) can be ignored
(ANA_L2::LRN_CFG.IGNORE_MCIDX_PORTMOVE_ENA).
3.20.6.2
Port Move Log
A port move occurs when an existing MAC table entry for (MAC, FID) is updated with new port
information (ADDR_TYPE and ADDR). Such an event is logged and reported (in
ANA_L2::MOVELOG_STICKY) by setting the bit corresponding to the new port.
If port moves continuously occurs, it may indicate a loop in the network or a faulty link aggregation
configuration.
Port moves for locked entries can be detected in
ANA_L2::LRN_CFG.LOCKED_PORTMOVE_DETECT_ENA.
3.20.6.3
Port Learn Limits
It is possible to specify the maximum number of entries in the MAC table per port.
Port limits can be specified per logical port (local link aggregated port) and per global link aggregated
port (GLAG) (ANA_L2:PORT_LIMIT:PORT_LIMIT_CTRL.PORT_LRN_CNT_LIMIT). These limits do not
take multicast into account.
The current number of learned entries are always available in
ANA_L2:PORT_LIMIT:PORT_LIMIT_STATUS.PORT_LRN_CNT and are updated whenever either an
automatic learn operation or a CPU access is performed.
After a limit is reached, both automatic learning and CPU-based learning of unlocked entries are denied.
A learn frame to be learned when the limit is reached can selectively be discarded, redirected to CPU, or
copied to CPU (controlled in ANA_L2:PORT_LIMIT:PORT_LIMIT_CTRL.PORT_LIMIT_EXCEED_SEL).
Trying to exceed the configured limit can also trigger interrupt
(ANA_L2:PORT_LIMIT:PORT_LIMIT_CTRL.PORT_LIMIT_EXCEED_IRQ_ENA).
When learn limits are exceeded, a corresponding sticky bit is set
(ANA_L2:PORT_LIMIT:PORT_LIMIT_STATUS.PORT_LRN_LIMIT_EXCEEDED_STICKY).
If a MAC table entry interrupt moves from one port to another port, it is also reflected in the current
number of learned entries.
3.20.6.4
Filtering Identifier Learn Limits
It is possible to specify the maximum number of entries to be used per FID
(ANA_L2:LRN_LIMIT:FID_LIMIT_CTRL.FID_LRN_CNT_LIMIT). These limits do not take multicast into
account.
The current number of learned entries are always available in
ANA_L2:LRN_LIMIT:FID_LIMIT_STATUS.FID_LRN_CNT.
After a limit is reached, both automatic learning and CPU-based learning of unlocked entries are denied.
A learn frame to be learned when the limit is reached can selectively be discarded, redirected to CPU, or
copied to CPU (controlled by ANA_L2:LRN_LIMIT:FID_LIMIT_CTRL.FID_LIMIT_EXCEED_SEL).
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
180
Functional Descriptions
Attempts to exceed the configured limit can also trigger interrupt
(ANA_L2:LRN_LIMIT:FID_LIMIT_CTRL.FID_LIMIT_EXCEED_IRQ_ENA).
When the learn limits are exceeded, a corresponding sticky bit is set
(ANA_L2:LRN_LIMIT:FID_LIMIT_STATUS.FID_LRN_LIMIT_EXCEEDED_STICKY).
3.20.6.5
Shared or Independent VLAN Learning in MAC Table
The devices can be set up to do a mix of Independent VLAN Learning (IVL), where MAC addresses are
learned separately on each VLAN and Shared VLAN Learning (SVL), where a MAC table entry is shared
among a group of VLANs. For shared VLAN learning, a MAC address and a filtering identifier (FID)
define each MAC table entry. A set of VIDs used for Shared VLAN learning maps to the same FID.
Shared VLAN learning is only applicable for unicast traffic.
Addresses learned from frames with one VLAN Identifier (VID) may or may not be used to filter frames
with the same SMAC but another VID, depending on management controls. If learned information is
shared for two or more given VIDs those VIDs map to a single Filtering Identifier (FID) and the term
Shared VLAN Learning (SVL) is used to describe their relationship. If the information is not shared, the
VIDs map to different FIDs and Independent VLAN Learning (IVL) is being used. FID is configured per
VLAN (ANA_L3:VLAN:VLAN_CFG.VLAN_FID).
For example, if VID 16 and VID 17 use SVL and share FID 16, then a MAC entry (MAC #X, FID 16) is
known for both VID 16 and VID 17.
If VID 16 and VID 17 use IVL and use FID 16 and FID 17, a MAC entry (MAC #X, FID 16) is only known
for VID 16; that is, the MAC address will be unknown for VID 17 (FID = 17).
In a VLAN-unaware operation, the devices are set up to do SVL; that is, MAC addresses are learned for
all VLANs. Protocol-based VLAN, where traffic is classified into multiple VLANs based on protocol,
requires SVL
3.20.7
Automated Aging (AUTOAGE)
This section describes how to configure automated age scanning. The following table lists the applicable
registers.
Table 122 • Automated Age Scan Registers Overview
Target::Register.Field
Description
Replication
LRN::AUTOAGE_CFG
Configures automated age scan of MAC table for each of 4
the four AGE_INTERVALs.
LRN::AUTOAGE_CFG_1
Configures automated age scan of MAC table.
1
LRN::AUTOAGE_CFG_2
Configures automated age scan of MAC table.
1
LRN::EVENT_STICKY.
AUTOAGE_SCAN_COMPLETED_STICKY
Signals completion of an automatic scan.
1
LRN::EVENT_STICKY.
AUTOAGE_SCAN_STARTED_STICKY
Signals start of an automatic scan.
1
LRN::EVENT_STICKY.
AUTOAGE_AGED_STICKY
Signals entries aged due to automatic aging.
1
LRN::EVENT_STICKY.
AUTOAGE_REMOVE_STICKY
Signals entries removed due to automatic aging.
1
ANA_L2::FILTER_LOCAL_CTRL
Configures front port filters to be used by automatic aging 1
and CPU scan.
ANA_L2::FILTER_OTHER_CTRL
Configures remote scan filter to be used by automatic
aging and CPU scan.
1
ANA_L2::LRN_CFG.AGE_SIZE
Configures the AGE_FLAG size.
1
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
181
Functional Descriptions
Entry AGE_FLAG is used to detect inactive sources. The AGE_FLAG field is cleared upon receiving
traffic from a given source station and is periodically incremented by hardware to detect and delete
inactive source entries.
The automated age scan scans the MAC table and checks age candidates (entries with LOCK flag set to
0) for activity.
If an entry’s AGE_FLAG is set to maximum value (configured in ANA_L2::LRN_CFG.AGE_SIZE), the
entry is deemed inactive and removed. If an entry’s AGE_FLAG is less than the maximum value, the
AGE_FLAG is incremented.
The flag is cleared when receiving frames from the station identified by the MAC table entry.
It is possible to configure and forget AUTOAGE, which means that once configured automated aging is
performed without any further CPU assistance.
The interval between automatic aging can be controlled by specifying AGE_FLAG size
(ANA_L2::LRN_CFG.AGE_SIZE), unit size (LRN::AUTOAGE_CFG.UNIT_SIZE), and the number of units
between aging (LRN::AUTOAGE_CFG.PERIOD_VAL).
Setting LRN::AUTOAGE_CFG.UNIT_SIZE different from 0 to start the automatic aging.
To temporarily disable automatic aging, set LRN::AUTOAGE_CFG. PAUSE_AUTO_AGE_ENA to 1.
Additional control of automatic aging allows for instantaneously start and stop of current age scan
(LRN::AUTOAGE_CFG_1.FORCE_HW_SCAN_SHOT and
LRN::AUTOAGE_CFG_1.FORCE_HW_SCAN_STOP_SHOT).
It is also possible to do a controlled stopping of current age scan after it completes
(LRN::AUTOAGE_CFG_1.FORCE_IDLE_ENA).
It is possible to selectively do age filtering of local ports specified in
ANA_L2::FILTER_LOCAL_CTRL.FILTER_FRONTPORT_ENA or selectively do age filtering of entries
learned on remote devices in a multichip configuration
(ANA_L2::FILTER_OTHER_CTRL.FILTER_REMOTE_ENA). Both types must be enabled
(LRN::AUTOAGE_CFG_1.USE_PORT_FILTER_ENA).
The state of automatic aging can be monitored (LRN::AUTOAGE_CFG_2.NEXT_ROW,
LRN::AUTOAGE_CFG_2.SCAN_ONGOING_STATUS,
LRN::EVENT_STICKY.AUTOAGE_SCAN_COMPLETED_STICKY and
LRN::EVENT_STICKY.AUTOAGE_SCAN_STARTED_STICKY).
It is possible to observe whether entries are affected by a sticky event
(LRN::EVENT_STICKY.AUTOAGE_AGED_STICKY and
LRN::EVENT_STICKY.AUTOAGE_REMOVE_STICKY).
Example
For a 300-second age time, set four age periods of 75 seconds each:
1.
2.
3.20.8
Set ANA_L2::LRN_CFG.AGE_SIZE to 1.
Set LRN::AUTOAGE_CFG[0]. AUTOAGE_UNIT_SIZE to 3.
Interrupt Handling
The following table lists the interrupt handling registers.
Table 123 • Analyzer Interrupt Handling Registers Overview
Target::Register.Field
Description
Replication
ANA_L2::INTR
Status of interrupt source
1
ANA_L2::INTR_ENA
Mask interrupt
1
ANA_L2::INTR_IDENT
Status of interrupt
1
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
182
Functional Descriptions
A sticky status of all interrupt sources in the analyzer is available (ANA_L2::INTR.VCAP_S2_INTR), and
all interrupt source can individually be configured to trigger CPU interrupt (ANA_L2::INTR_ENA). The
current CPU interrupt status is available (ANA_L2::INTR_IDENT).
The following analyzer interrupt sources exist:
VCAP IS2 can be setup to trigger CPU interrupt (VCAP_S2_INTR) when an entry with enabled interrupt
is hit (VCAP IS2 action INTR_ENA).
It is possible to trigger interrupt (PORT_LRN_LIMIT_INTR) when learning on a port attempt to exceed a
configured port learn limit (configured in
ANA_L2:PORT_LIMIT:PORT_LIMIT_CTRL.PORT_LIMIT_EXCEED_IRQ_ENA).
It is possible to trigger interrupt (FID_LRN_LIMIT_INTR) when learning on a FID attempt to exceed a
configured limit (configured in ANA_L2:LRN_LIMIT:FID_LIMIT_CTRL.FID_LIMIT_EXCEED_IRQ_ENA).
LRN access to the MAC table can be configured to trigger interrupt (LRN_ACCESS_COMPLETE_INTR)
after completion. This is useful when multiple CPU scans must be performed as fast as possible, for
example, when sorting the MAC addresses extracted from the entire MAC table using SCAN commands.
For more information about using the SCAN command, see SCAN Command, page 174.
3.21
Analyzer Access Control Forwarding, Policing, and
Statistics
This section provides information about analyzer access control (ANA_AC) forwarding, policing, and
statistics.
3.21.1
Mask Handling
This section describes how a number of port masks are applied to ensure correct forwarding.
•
•
•
•
•
•
VLAN port mask from ANA_L3:VLAN. This mask is used to ensure frames are only forwarded within
a dedicated VLAN (or VSI if service forwarded). The VLAN mask handle protection by means of
hardware assisted updates. For more information, see VLAN Table Update Engine, page 126. The
VLAN mask can be modified by VCAP CLM full action MASK_MODE and by VCAP IS2 action
MASK_MODE.
PGID port mask from ANA_AC:PGID. This mask is based on the DMAC lookup in the PGID table.
One of the six flood PGID entries is used if the DMAC is unknown. For DMAC known in the MAC
table, the associated address is used to select the used PGID entry.
Source port mask from ANA_AC:SRC. This mask is used to ensure frames are never forwarded to
the port it was received on and the used entry is found by looking up the source port.
Global source port mask from ANA_AC:SRC. This mask is used to ensure frames are never
forwarded to the global port it was received on and the used entry is found by looking up the global
stacking source port.
Aggregation port mask from ANA_AC:AGGR. This mask is used to ensure frames are forwarded to
one port within each aggregate destination port.
REQ.port_mask and REQ.mask_mode. This mask is special in the sense that it is a general purpose
mask that can be used for various security features and protection. The mask is controlled by VCAP
CLM and VCAP IS2.
The following sections provide more information about the different port masks.
3.21.1.1
PGID Lookup
The following table lists the registers associated with PGID lookup.
Table 124 • PGID Registers Overview
Target::Register.Field
Description
Replication
ANA_AC:PGID:PGID_MISC_CFG
Configures how to interpret PGID_CFG and PGID_CFG1 and
configures CPU copy with associated CPU queue.
per PGID
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
183
Functional Descriptions
Table 124 • PGID Registers Overview (continued)
Target::Register.Field
Description
Replication
ANA_AC:PGID:PGID_CFG
ANA_AC:PGID:PGID_CFG1
Configures destination port mask or destination {UPSID,PN}.
per PGID
The PGID table is organized as shown in the following illustration.
Figure 32 • PGID Layout
mc_idx:0x3ff
GLAG 31 mbr 7
GLAG or General
Purpose Destinations
GLAG 0 mbr 1
GLAG 0 mbr 0
mc_idx:0x2ff
PGID ADDR
0x434
0x335
General Purpose Destination n
General Purpose
Destinations
0
Front Port Mask
52
General Purpose Destination 0
General Purpose Destination 1
mc_idx:0x006
mc_idx:0x000
0
0
0
0
0
0
0
IP6 MC Control Flood Mask
IP6 MAC Data Flood Mask
IP4 MC Control Flood Mask
IP4 MC Data Flood Mask
L2 Multicast Flood Mask
L2 Unicast Flood Mask
Port 52 Destination Mask
0
0
Port 1 Destination Mask
Port 2 Destination Mask
1
0x03B
Reserved (must be zero)
52
0
0
UPSID UPSPN
9
5
0
0x035
Front Port Unicast
Destination Mask
0x000
STACK interpret
The forwarding process generates a forwarding decision that is used to perform a lookup in the PGID
table. The following forwarding decisions are possible.
•
•
Flood forwarding to one of the six flood masks located from address 53 to address 58 in the PGID
table is used as destination mask.
Unicast forwarding to {UPSID,UPSPN}. UPSID is checked against
ANA_AC::COMMON_VSTAX_CFG.OWN_UPSID:
If identical, destination mask is found based on lookup of UPSPN within the front port destinations of
the PGID table (address 0 to 52).
If not identical, destination mask is found based on lookup of UPSID in
ANA_AC:UPSID:UPSID_CFG.
•
Multicast forwarding: mc_idx is looked up in the PGID table with an offset of 53. Based on the
returned entry stack bit:
If cleared, the returned entry mask is interpreted as a destination mask.
If set, the returned entry mask is {UPSID,UPSPN} and the destination mask is found based on
lookup of UPSID in ANA_AC:UPSID:UPSID_CFG.
•
REQ destination set (REQ.COMMON.PORT_MASK when
REQ.COMMON.MASK_MODE=REPLACE_PGID). Destination set (REQ.COMMON.PORT_MASK
from VCAP CLM or VCAP IS2 is directly used as destination mask without PGID lookup.
REQ.L2_FWD cleared. Frame is discarded.
•
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
184
Functional Descriptions
It is possible to generate a CPU copy can be generated when using the PGID lookup. If
ANA_AC:PGID:PGID_MISC_CFG.PGID_CPU_COPY_ENA is set in the used PGID entry, a copy is sent
to CPU queue specified by ANA_AC:PGID:PGID_MISC_CFG.PGID_CPU_QU.
The following illustration depicts the PGID lookup decision.
Figure 33 • PGID Lookup Decision Forwarding
Select PGID entry
# Redirect via PGID entry?
REQ.COMMON.MASK_MODE == REDIR_PGID ?
false
#Unknown DMAC?
Req.Flood?
# PGID index from VCAP CLM or VCAP_S2
PGID_ENTRY :=
PGID_TBL(REQ.COMMON.PORT_MASK( 7:0))
true
Flood decison
true
req.l2_uc=1?
true
# Unicast flood
PGID_ENTRY := PGID_TBL(53)
true
# IP4 MC CTRL flood
PGID_ENTRY := PGID_TBL(56)
req.ip_mc=1 and req.ip4_avail=1 ?
true
req.ip_mc_ctrl=1?
# IP4 MC DATA flood
PGID_ENTRY := PGID_TBL(55)
false
false
req.ip_mc=1 and req.ip6_avail=1 ?
false
true
req.ip_mc_ctrl=1?
true
# IP6 MC DATA flood
PGID_ENTRY := PGID_TBL(57)
false
# L2 MC flood
PGID_ENTRY := PGID_TBL(54)
false
req.dst.fwd_type==MC_IDX?
# IP6 MC CTRL flood
PGID_ENTRY := PGID_TBL(58)
PGID_ENTRY := PGID_TBL(53
+req.dst.fwd_addr.mc_idx)
true
false
req.dst.fwd_type==UPSID_PN?
true
IsOwnUpsid(req.dst.fwd_addr.upsid)?
true
PGID_ENTRY :=
PGID_TBL(req.dst.fwd_addr.upspn)
false
false
IFH.VSTAX.GEN := FWD_LOGICAL
IFH.VSTAX.DST:UPSID := req.dst.fwd_addr.upsid;
IFH.VSTAX.DST:UPSPN := req.dst.fwd_addr.upspn;
do_stack_upsid_fwd
:= true;
No PGID lookup
Done selecting
PGID entry
The following debug events can be used to observe current forwarding:
ANA_AC:PS_STICKY:STICKY.PGID_CPU_MASK_STICKY,
ANA_AC:PS_STICKY:STICKY.NO_L2_L3_FWD_STICKY,
ANA_AC:PS_STICKY:STICKY.IP6_MC_CTRL_FLOOD_STICKY,
ANA_AC:PS_STICKY:STICKY.IP6_MC_DATA_FLOOD_STICKY,
ANA_AC:PS_STICKY:STICKY.IP4_MC_CTRL_FLOOD_STICKY,
ANA_AC:PS_STICKY:STICKY.IP4_MC_DATA_FLOOD_STICKY,
ANA_AC:PS_STICKY:STICKY.L2_MC_FLOOD_STICKY and
ANA_AC:PS_STICKY:STICKY.UC_FLOOD_STICKY
The events can be counted in the port statistics block by setting the corresponding counter
mask:ANA_AC:PS_STICKY_MASK:STICKY_MASK
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
185
Functional Descriptions
3.21.1.2
Source Lookup
This section describes how to configure source port filtering. The following table lists the applicable
registers.
Table 125 • Source Table Registers Overview
Target::Register.Field
Description
Replication
ANA_AC:SRC:SRC_CFG
ANA_AC:SRC:SRC_CFG1
Configures source port filtering
89
Source port filtering for each ingress port can be configured to ensure that frames are not bridged back to
the port it was received on (ANA_AC:SRC[0-56]:SRC_CFG).
Ports part of a link aggregation group (LAG) are configured with identical source masks, with all member
ports removed (bits corresponding to the member ports are cleared).
If a port is part of a global link aggregation group, a filter is applied to ensure that frames received at this
port are not bridged back to any of the ports in the global link aggregation group of which the source port
is part (ANA_AC:SRC[57-88]:SRC_CFG).
Local device ports part of a global link aggregation group must be cleared in the global aggregation
source mask (via ANA_AC:SRC[57-88]:SRC_CFG).
Source port filtering can be disabled when VCAP IS2 action MASK_MODE is set to 4 (= REDIR_PGID).
Source port filtering is not applied when a frame is routed.
3.21.1.3
Aggregation Group Port Selection
This section describes how to configure the aggregation table. The following table lists the applicable
registers.
Table 126 • Aggregation Table Registers Overview
Target::Register.Field
Description
Replication
ANA_AC:AGGR:AGGR_CFG
ANA_AC:AGGR:AGGR_CFG1
Configures aggregation port filtering.
16
The purpose of the aggregation table is to ensure that when a frame is destined for an aggregation
group, it is forwarded to exactly one of the group’s member ports.
The aggregation code REQ.AGGR_CODE generated in the classifier is used to look up an aggregation
mask in the aggregation table. Aggregation mask is configured in ANA_AC:AGGR:AGGR_CFG.
For non-aggregated ports, there is a one-to-one correspondence between logical port (ANA_CL:PORT:
PORT_ID_CFG.LPORT_NUM) and physical port, and the aggregation table does not change the
forwarding decision.
For aggregated ports, all physical ports in the aggregation group map to the same logical port, and
destination entries for a logical port in the PGID table must include all physical ports, which are members
of the aggregation group. Therefore, all but one LAG member port must be removed from the destination
port set.
For more information about link aggregation, see Link Aggregation Code Generation, page 110
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
186
Functional Descriptions
3.21.1.4
Global Link Aggregation Forwarding
This section describes how to configure forwarding to a GLAG. The following table lists the applicable
registers.
Table 127 • GLAG Forward Registers Overview
Target::Register.Field
Description
Replication
ANA_AC::COMMON_VSTAX_CFG Configures VSTAX handles.
1
ANA_AC:GLAG:MBR_CNT_CFG
32
Configures number of members per GLAG.
The devices perform a final port of exit (POE) calculation in ingress device when destination is a global
aggregated port. GLAG POE calculation must be enabled
(ANA_AC::COMMON_VSTAX_CFG.VSTAX2_GLAG_ENA). When enabled, GLAG forwarding uses a
portion of the PGID table (addresses 821 to 1076). These addresses must use UPSID, UPSPN encoding
by setting the stack interpret bit.
POE calculation, which selects one of the global aggregated as destination port, is shown in the following
illustration.
Figure 34 • GLAG Port of Exit Calculation
glag_mbr_cnt_table
dmac
MAC Table
glagid
glag_mbr_cnt
glag_mbr_idx := ac mod glag_mbr_cnt
glag part of PGID table
{glagid, glag_mbr_idx}
{upsid, upspn}
The total number of ports part of a GLAG must be specified in ANA_AC:GLAG:MBR_CNT_CFG.
The corresponding destination must be configured in PGID table for each GLAG member.
3.21.1.5
Port Mask Operation
The final destination port mask are deducted as shown in the following illustration.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
187
Functional Descriptions
Figure 35 • Port Mask Operation
Mask Operation
# Prepare masks
src_mask := SrcTable(REQ.COMMON.PORTNUM)
aggr_mask := AggrTable(REQ.COMMON.AC)
# Forwarding controlled from CLM or VCAP_S2?
REQ.COMMON.MASK_MODE == REPLACE_ALL?
false
true
# Overrule forwarding from CLM or VCAP_S2?
REQ.COMMON.MASK_MODE == REPLACE_PGID?
true
# Replace pgid destination port mask
pgid_mask := REQ.COMMON.PORT_MASK
true
# Add to pgid destination port mask
pgid_mask |= REQ.COMMON.PORT_MASK
true
# Ignore source filtering
src_mask := ALL_ONES
true
# Ignore Aggregation mask
aggr_mask := ALL_ONES
false
# Normal PGID forwarding
pgid_mask := PgidLookupSel(REQ)
# Add forwarding from CLM or VCAP_S2?
REQ.COMMON.MASK_MODE == OR_PGID_MASK?
false
# Source filtering?
ANA_L2:ISDX:SERVICE_CTRL.SRC_MASK_DIS ||
REQ.L3_FWD?
false
# Aggreration selection?
ANA_L2:ISDX:SERVICE_CTRL.AGGR_REPLACE_EN
A==0 && ANA_L2:ISDX:SERVICE_CTRL.AGGR_VAL
!= 0?
false
dst_mask := pgid_mask &&
src_mask && aggr_mask && REQ.VLAN_PORT_MASK
# Additional forwarding from CLM or VCAP_S2?
REQ.COMMON.MASK_MODE == OR_DST_MASK?
true
# Add to final destination port mask
dst_mask |= REQ.COMMON.PORT_MASK
# Final destination port mask
dst_mask := REQ.COMMON.PORT_MASK
false
Done selecting destination port mask
3.21.2
Policing
This section describes the functions of the policers. The following table lists the applicable registers.
Table 128 • Policer Control Registers Overview
Target::Register.Field
Description
Replication
ANA_AC_POL::POL_ALL_CFG
Configures general control settings.
1
ANA_AC_POL::POL_ACL_CTRL
Configures VCAP policer’s mode of operation.
32
ANA_AC_POL::POL_ACL_RATE_CFG
Configures VCAP policer’s peak information rate 32
ANA_AC_POL::POL_ACL_THRES_CFG
Configures VCAP policer’s burst capacity.
32
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
188
Functional Descriptions
Table 128 • Policer Control Registers Overview (continued)
Target::Register.Field
Description
Replication
ANA_AC_POL::POL_STORM_CTRL
Configures storm policer’s mode of operation.
8
ANA_AC_POL::POL_STORM_RATE_CFG
Configures storm policer’s peak information rate 8
ANA_AC_POL::POL_STORM_THRES_CFG
Configures Storm policer’s burst capacity.
8
ANA_AC_POL::POL_PORT_RATE_CFG
Configures port policer’s peak information rate.
Per port per
port policer
ANA_AC_POL::POL_PORT_THRES_CFG_0
Configures port policer’s burst capacity.
Per port per
port policer
ANA_AC_POL::POL_PORT_THRES_CFG_1
Configures port policer’s hysteresis when used
for flow control.
Per port per
port policer
ANA_AC_POL:POL_PORT_CTRL:POL_PORT_ Configures port policer’s mode of operation.
CFG
Per port per
port policer
ANA_AC_POL:POL_PORT_CTRL:POL_PORT_ Configures port policer’s gap value used to
GAP
correct size per frame.
Per port
ANA_AC_POL::POL_PORT_FC_CFG
Configures port policer’s flow control settings
Per port
ANA_AC_POL::POL_STICKY
Captures various policer events for diagnostic
purposes.
1
ANA_AC_POL:COMMON_SDLB:DLB_CTRL
Configures common SDLB policer’s mode of
operation.
1
ANA_AC_POL:COMMON_SDLB:DLB_STICKY
Captures various SDLB policer events for
diagnostic purposes.
1
ANA_AC_POL:SDLB:DLB_CFG
Configures SDLB policer’s mode of operation.
Per SDLB
ANA_AC_POL:SDLB:LB_CFG
Configures SDLB policer’s committed and peak
leaky buckets
Per SDLB per
leaky bucket
3.21.2.1
Policer Hierarchy
There are multiple levels of policing, which operate in configurable hierarchies, as shown in the following
illustration.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
189
Functional Descriptions
Figure 36 • Policer Hierarchy
ASP statistics
VCAP DROP and
PASS statistics
Outer VCAP
policers
BUNDLE DROP
statistics
BUM DROP and
PASS statistics
BUM
policers
Service
policers
ISDX 0 AND
SDLB IDX 0?
Pol
Port
Port
#2
Pol
Pol
#1
#0
Yes isdx based
index
No
VCAP DLB
enable?
Yes
No
(SLB)
(3x SLB)
VCAP
based
index
Bundle
policers
Port DROP and
PASS statistics
VCAP DROP and
PASS statistics
Inner VCAP
policers
Port
policers
Global
storm
policers
Port
Port
Pol
Pol
#1
Pol
Port
Port
#7
Pol
Pol
#1
No
ISDX 0 AND
SERVICE_BYPA
SS_ENA?
isdx based
index
Yes
Port based
index
#0
#0
queue
based
index
(DLB)
(DLB)
(SLB)
(2x SLB)
(8x SLB)
Either outer or
Inner VCAP policer
exists selectable per
VCAP_S2 lookup
At most, each frame can see one ACL policer. ACL policing can occur as either outer or inner ACLbased. VCAP IS2 action IS_INNER_ACL allows ACL policing to occur before or after service DLB
policing and service statistics.
The VCAP, port, broadcast/unicast/multicast (BUM), and storm policers are single leaky bucket (SLB)
policers, whereas the service and bundle policers are MEF 10.2 compliant dual leaky bucket (DLB)
policers.
The BUM policers group the leaky buckets into sets of three, covering broadcast, unicast, and multicast
traffic.
The VCAP, port and storm policers are configurable in steps of 25,040 bits per second, with a minimum
of 25,040 bits per second.
The BUM, service, and bundle policers can cover bandwidth in the interval between 0 Gbps and
32 Mbps, with 16 kbps granularity and between 0 Gbps and 10 Gbps with 8 Mbps granularity. The
granularity scaling can be configured using the TIMESCALE_VAL configuration parameters.
The service policers can be used as queue policers for non-service traffic when ISDX is zero and
ISDX_SDLB index is zero. The queue policer operation is controlled through
ANA_L2:COMMON:FWD_CFG.QUEUE_DEFAULT_SDLB_ENA and
ANA_L2:COMMON:PORT_DLB_CFG.QUEUE_DLB_IDX.
The bundle policers are only available for services. The index is controlled through
ANA_L2:ISDX:MISC_CFG.BDLB_IDX. However, it is possible to use the bundle policers as port policers
for non-service traffic when ISDX is zero. The port policer operation is controlled through
ANA_L2:COMMON:FWD_CFG.PORT_DEFAULT_BDLB_ENA and
ANA_L2:COMMON:PORT_DLB_CFG.PORT_DLB_IDX.
It is possible to specify a pipeline point for the service policers
(ANA_L2:ISDX:MISC_CFG.PIPELINE_PT). This can be used to specify where in the processing flow
BUM, SDLB, and BDLB policers are active (default set to NONE, which disables any pipeline effect).
The service statistics reflect the decisions made by the service policer. This implies that if a service
policer marks a frame yellow, then the yellow service counter is incremented even though the frame
might be discarded by one of the subsequent policers.
All policers can be configured to add between –64 and 63 bytes per frame to adjust the counted frame
size for inter-frame gap and/or encapsulation.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
190
Functional Descriptions
3.21.2.2
Service and Bundle Dual Leaky Bucket (DLB) Policing
Each entry in the service dual leaky bucket (SDLB) and bundle dual leaky bucket (BDLB) tables contains
the fields listed in the following table. In this section, “xDLB” is used to reference register groups for both
service policers and bundle policers.
Table 129 • Service and Bundle Dual Leaky Bucket Table Entries
Field
Bits
Description
ANA_AC_POL:xDLB:DLB_CFG. 2
TIMESCALE_VAL
Configures DLB policer granularity.
ANA_AC_POL:xDLB:DLB_CFG. 2
COLOR_AWARE_LVL
Corresponds to MEF color mode. Specifies the highest DP level that is
treated as green (that is, service frames with DP level above
COLOR_AWARE_LVL are considered yellow). COLOR_AWARE_LVL == 3
correspond to color-blind.
ANA_AC_POL:xDLB:DLB_CFG. 1
COUPLING_MODE
MEF Coupling Flag (CF).
Depending on the setting of COUPLING_MODE, LB_CFG[0] and
LB_CFG[1] must be configured as follows:
If COUPLING_MODE = 0:
LB_CFG[0].RATE_VAL must be configured to MEF CIR.
LB_CFG[0].THRES_VAL must be configured to MEF CBS.
LB_CFG[1].RATE_VAL must be configured to MEF EIR.
LB_CFG[1].THRES_VAL must be configured to MEF EBS.
If COUPLING_MODE = 1:
LB_CFG[0].RATE_VAL must be configured to MEF CIR.
LB_CFG[0].THRES_VAL must be configured to MEF CBS.
LB_CFG[1].RATE_VAL must be configured to MEF EIR + MEF CIR.
LB_CFG[1].THRES_VAL must be configured to MEF EBS + MEF CBS.
ANA_AC_POL:xDLB:DLB_CFG. 2
CIR_INC_DP_VAL
Controls how much drop precedence (DP) is incremented for excess traffic.
ANA_AC_POL:xDLB:DLB_CFG. 7
GAP_VAL
Configures the leaky bucket calculation to include or exclude preamble,
inter-frame gap and optional encapsulation through configuration.
ANA_AC_POL:xDLB:LB_CFG[0] 7
.THRES_VAL
Configures committed burst size (CBS).
ANA_AC_POL:xDLB:LB_CFG[1] 7
.THRES_VAL
Configures DLB’s second threshold. See COUPLING_MODE.
ANA_AC_POL:xDLB:LB_CFG[0] 11
.RATE_VAL
Configures DLB’s second rate. See COUPLING_MODE.
Each MEF DLB policer supports the following configurations.
•
•
•
•
•
Two rates. Specified in 2,048 steps (ANA_AC_POL:xDLB:LB_CFG[0-1].RATE_VAL).
Two burst sizes. Specified in steps of 2 kilobytes (up to 254 kilobytes)
(ANA_AC_POL:xDLB:LB_CFG[0-1].THRES_VAL).
Color mode: Color-blind or color-aware. Specifies a DP level to separate traffic as green or yellow
(ANA_AC_POL:xDLB:DLB_CFG.COLOR_AWARE_LVL). Frames classified with REQ.DP below or
equal to COLOR_AWARE_LVL are treated as green. Frames with REQ.DP above
COLOR_AWARE_LVL are treated as yellow. A policer is color-blind if configured with a
COLOR_AWARE_LVL of 3.
Coupling flag. Coupled or uncoupled (ANA_AC_POL:xDLB:DLB_CFG.COUPLING_MODE).
Change DP level. The increase to REQ.DP level when CIR rate is exceeded
(ANA_AC_POL:xDLB:DLB_CFG.CIR_INC_DP_VAL).
In addition, the following parameters can also be configured per policer:
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
191
Functional Descriptions
•
•
Leaky bucket calculations can be configured to include or exclude preamble, inter-frame gap and an
optional encapsulation (ANA_AC_POL:SDLB:DLB_CFG.GAP_VAL).
Policers can be configured to police CPU traffic, front port forwarded traffic, or both
(ANA_AC_POL:xDLB:DLB_CFG.TRAFFIC_TYPE_MASK).
The DLB policers must also be enabled in ANA_AC_POL:COMMON_xDLB:DLB_CTRL.LEAK_ENA and
ANA_AC_POL:COMMON_xDLB:DLB_CTRL.DLB_ADD_ENA.
The DLB policer unit size can be adjusted (ANA_AC_POL:COMMON_xDLB:
DLB_CTRL.BASE_TICK_CNT) to configure various base units (= smallest rate granularity).
The following DLB policer debug events are available:
•
•
•
•
3.21.2.3
Dropping traffic due to DLB policer can be identified (ANA_AC_POL:POL_ALL_CFG:
POL_STICKY.POL_DLB_DROP_STICKY).
Traffic received without triggering CIR and PIR policing
(ANA_AC_POL:COMMON_xDLB:DLB_STICKY.CIR_PIR_OPEN_STICKY).
Committed information rate exceeded
(ANA_AC_POL:COMMON_xDLB:DLB_STICKY.CIR_EXCEEDED_STICKY).
Peak information rate exceeded
(ANA_AC_POL:COMMON_xDLB:DLB_STICKY.PIR_EXCEEDED_STICKY).
BUM Policing
Each entry in the BUM single leaky bucket table contains the following fields.
Table 130 • BUM Single Leaky Bucket Table Entries
Field
Bits
Description
ANA_AC_POL:BUM_SLB:SLB_CFG.
TIMESCALE_VAL
2
Configures policer rate granularity.
ANA_AC_POL:BUM_SLB:SLB_CFG.
CIR_INC_DP_VAL
2
Controls how much drop precedence (DP) is incremented
for excess traffic.
ANA_AC_POL:BUM_SLB:SLB_CFG.
GAP_VAL
7
Configures the leaky bucket calculation to include or exclude
preamble, inter-frame gap and optional encapsulation
through configuration.
ANA_AC_POL:BUM_SLB:LB_CFG[2:0].
THRES_VAL
3x7
Configures burst size.
ANA_AC_POL:BUM_SLB:LB_CFG[2:0].
RATE_VAL
3 x 11
Configures rate.
ANA_AC_POL:BUM_SLB:SLB_CFG.ENCAP_ 1
DATA_DIS
Configures if stripped encapsulation data (normalized data)
is policed by the policer.
ANA_AC_POL:BUM_SLB:MISC_CFG.FRAME 1
_RATE_ENA
Configures frame rate operation.
The BUM policers are indexed through the VLAN table (ANA_L3:VLAN:BUM_CFG.BUM_SLB_IDX). This
indexing can be overruled for services through the ISDX table
(ANA_L2:ISDX:MISC_CFG.BUM_SLB_IDX and ANA_L2:ISDX:MISC_CFG.BUM_SLB_ENA).
Each BUM policer contains three leaky buckets. Rates and thresholds are configured through
ANA_AC_POL:BUM_SLB:LB_CFG).
Traffic for the three BUM leaky buckets is configurable in
ANA_AC_POL:COMMON_BUM_SLB:TRAFFIC_MASK_CFG. This provides a flexible allocation of traffic
for the policers. For example, it is possible to have BUM configured as:
•
•
Leaky bucket 0: Broadcast traffic
(ANA_AC_POL:COMMON_BUM_SLB:TRAFFIC_MASK_CFG[0].TRAFFIC_TYPE_MASK = 1)
Leaky bucket 1: Unknown unicast traffic
(ANA_AC_POL:COMMON_BUM_SLB:TRAFFIC_MASK_CFG[1].TRAFFIC_TYPE_MASK = 4)
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
192
Functional Descriptions
•
Leaky bucket 2: Unknown multicast traffic
(ANA_AC_POL:COMMON_BUM_SLB:TRAFFIC_MASK_CFG[2]. TRAFFIC_TYPE_MASK = 2)
BUM policers can be configured as frame-based policers
(ANA_AC_POL:BUM_SLB:MISC_CFG.FRAME_RATE_ENA).
The BUM statistics count on the following events (configured through
ANA_AC:STAT_GLOBAL_CFG_BUM:STAT_GLOBAL_EVENT_MASK):
•
•
•
•
•
•
3.21.2.4
Bit 0: Count Broadcast traffic discarded by BUM policer
Bit 1: Count Multicast traffic discarded by BUM policer
Bit 2: Count Unicast traffic discarded by BUM policer
Bit 3: Count Broadcast traffic applicable for BUM policer, but not discarded
Bit 4: Count Multicast traffic applicable for BUM policer, but not discarded
Bit 5: Count Unicast traffic applicable for BUM policer, but not discarded.
ACL Policing
Each ACL policer entry contains the fields listed in the following table.
Table 131 • ACL Policer Table Entries
Field
Bits
Description
ACL_TRAFFIC_TYPE_MASK
2
Configures the traffic types to be taken into account by the policer.
FRAME_RATE_ENA
1
Configures frame rate mode for the ACL policer, where rates are measured
in frames per second instead of bytes per second.
DP_BYPASS_LVL
2
Controls the lowest DP level that is taken into account. That is, traffic with
DP_BYPASS_LVL below this value is ignored and not policed.
GAP_VALUE
7
Configures the leaky bucket calculation to include or exclude preamble,
inter-frame gap, and optional encapsulation through configuration.
ACL_THRES
6
Configures ACL policer burst capacity.
ACL_RATE
17
Configures ACL policer rate.
At most, a frame can trigger one ACL policer. ACL policers are enabled by specifying a rate in
ANA_AC_POL:POL_ALL_CFG:POL_ACL_RATE_CFG.ACL_RATE and also enabled by a VCAP IS2 hit.
For more information, see VCAP IS2, page 63.
The policer burst capacity can be specified with 4K granularity
(ANA_AC_POL:POL_ALL_CFG:POL_ACL_THRES_CFG.ACL_THRES).
The following parameters can also be configured per policer.
•
•
•
•
The leaky bucket calculation can be configured to include or exclude preamble, inter-frame gap and
an optional encapsulation (ANA_AC_POL:POL_ALL_CFG:POL_ACL_CTRL.GAP_VALUE).
Traffic with DP level below a certain level can be configured to bypass the policers
(ANA_AC_POL:POL_ALL_CFG:POL_ACL_CTRL.DP_BYPASS_LVL).
Each policer can be configured to measure frame rates instead of bit rates
(ANA_AC_POL:POL_ALL_CFG:POL_ACL_CTRL.FRAME_RATE_ENA).
Each ACL policer can be configured to operate on frames towards CPU and/or front ports
(ANA_AC_POL:POL_ALL_CFG:POL_ACL_CTRL.ACL_TRAFFIC_TYPE_MASK).
Traffic dropped by an ACL policer can be counted in the ACL statistics block and optionally also in the
port statistic block. For more information, see Analyzer Statistics, page 197.
The following ACL policer debug events are available:
•
•
Bypass of policer due to pipeline handling can be identified
(ANA_AC_POL:POL_ALL_CFG:POL_STICKY.POL_ACL_PT_BYPASS_STICKY).
Bypass of policer due to bypass level can be identified
(ANA_AC_POL:POL_ALL_CFG:POL_STICKY.POL_ACL_BYPASS_STICKY).
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
193
Functional Descriptions
•
•
Dropping of traffic due to ACL policer can be identified
(ANA_AC_POL:POL_ALL_CFG:POL_STICKY.POL_ACL_DROP_STICKY).
Policers that are active but not closed can be identified
(ANA_AC_POL:POL_ALL_CFG:POL_STICKY.POL_ACL_ACTIVE_STICKY).
For example, to use ACL policers to limit traffic to CPU only, the following configuration is required:
•
•
•
•
3.21.2.5
Set up a VCAP S2 rule to enable ACL policer 5.
Configure ACL policer 5 to only allow 100 frames per second towards CPU: # the rate is 10 times the
configured value ANA_AC_POL:POL_ALL_CFG:POL_ACL_RATE_CFG[5].ACL_RATE = 10
ANA_AC_POL:POL_ALL_CFG:POL_ACL_CTRL[5].FRAME_RATE_ENA = 1
Do not accept burst: ANA_AC_POL:POL_ALL_CFG:POL_ACL_THRES_CFG[5].ACL_THRES = 0
Only police traffic towards CPU:
ANA_AC_POL:POL_ALL_CFG:POL_ACL_CTRL[5].ACL_TRAFFIC_TYPE_MASK = 2
Priority Policing
The configuration parameters for priority policing are listed in the following table.
Table 132 • Priority Policer Table Entry
Field
Description
ANA_L2::FWD.QUEUE_DEFAULT_SDLB_ENA
Enables priority policers for non-service frames.
ANA_L2:PORT:PORT_DLB_CFG.QUEUE_DLB_IDX
Specifies which DLB policers are used for priority policing.
Non-service frames (which ISDX = 0 and ANA_L2:ISDX:DLB_CFG.DLB_IDX = 0) can use the service
policers as priority policers. This is enabled in ANA_L2::FWD_CFG.QUEUE_DEFAULT_SDLB_ENA.
The frame’s ingress port and classified QoS class select the priority policer. The configuration of the
priority policer follows the configuration of the service policers. For more information, see Service and
Bundle Dual Leaky Bucket (DLB) Policing, page 191.
Note that a DLB policer index enabled by VCAP IS2 action ACL_MAC[16] takes precedence over the
priority policing. In that case the frame is policed by the VCAP selected policer and not the priority
policer.
3.21.2.6
Port Policing
Each port policer entry contains the fields listed in the following table.
Table 133 • Port Policer Table Entry
Field
Bits
Description
TRAFFIC_TYPE_MASK
8
Configures the traffic types to be taken into account by the policer.
FRAME_RATE_ENA
1
Configures frame rate mode for the port policer, where rates are measured
in frames per second instead of bytes per second.
LIMIT_NONCPU_TRAFFIC_ENA
1
Configures how policing affects traffic towards front ports.
LIMIT_CPU_TRAFFIC_ENA
1
Configures how policing affects traffic towards CPU.
CPU_QU_MASK
8
Configures policing of frames to the individual CPU queues for the port
policer (see TRAFFIC_TYPE_MASK).
FC_ENA
1
Configures port policer to trigger flow control.
FC_STATE
1
Current flow control state.
DP_BYPASS_LVL
2
Controls the lowest DP level that is taken into account. That is, traffic with
DP_BYPASS_LVL below this value is ignored and not policed.
GAP_VALUE
7
Configures the leaky bucket calculation to include or exclude preamble,
inter-frame gap and optional encapsulation through configuration.
PORT_THRES0
6
Configures port policer burst capacity.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
194
Functional Descriptions
Table 133 • Port Policer Table Entry (continued)
Field
Bits
Description
PORT_THRES1
6
Configures port policer hysteresis size when a port policer is in flow control
mode (see FC_ENA).
PORT_RATE
17
Configures port policer rate.
Frames applicable for policing are any frames received by the MAC and forwarded to the classifier. Short
frames (less than 148 bytes) with errors, pause frames, or MAC control frames are not forwarded by the
MAC and therefore not accounted for in the policers. That is, they are not policed and do not add to the
rate measured by the policers.
Port policers are enabled by configuring the traffic type to be policed
(ANA_AC_POL:POL_PORT_CTRL:POL_PORT_CFG.TRAFFIC_TYPE_MASK) and specifying a
corresponding rate (ANA_AC_POL:POL_PORT_CFG:POL_PORT_RATE_CFG.PORT_RATE).
The policer burst capacity can be specified with 4K granularity
(ANA_AC_POL:POL_PORT_CFG:POL_PORT_THRES_CFG_0.PORT_THRES0).
Policing of traffic destined for CPU port or ports can be controlled (in
ANA_AC_POL:POL_PORT_CTRL:POL_PORT_CFG.TRAFFIC_TYPE_MASK(7) = 0 and CPU bypass
mask in ANA_AC_POL:POL_PORT_CTRL:POL_PORT_CFG.CPU_QU_MASK).
Port policers can individually be configured to affect frames towards CPU ports
(ANA_AC_POL:POL_PORT_CTRL:POL_PORT_CFG.LIMIT_CPU_TRAFFIC_ENA) or front ports
(ANA_AC_POL:POL_PORT_CTRL:POL_PORT_CFG.LIMIT_NONCPU_TRAFFIC_ENA).
The port policers can be configured for either serial or parallel operation
(ANA_AC_POL::POL_ALL_CFG.PORT_POL_IN_PARALLEL_ENA):
•
•
Serial. The policers are checked one after another. If a policer is closed, the frame is discarded and
the subsequent policer buckets are not updated with the frame.
Parallel. The policers are working in parallel independently of each other. Each frame is added to a
policer bucket if the policer is open, otherwise the frame is discarded. A frame may be added to one
policer although another policer is closed.
The following parameters can also be configured per policer.
•
•
•
The leaky bucket calculation can be configured to include or exclude preamble, inter-frame gap and
an optional encapsulation (ANA_AC_POL:POL_PORT_CTRL:POL_PORT_GAP.GAP_VALUE).
Each policer can be configured to measure frame rates instead of bit rates
(ANA_AC_POL:POL_PORT_CTRL:POL_PORT_CFG.FRAME_RATE_ENA).
Traffic with DP level below a certain level can be configured to bypass the policers
(ANA_AC_POL:POL_PORT_CTRL:POL_PORT_CFG.DP_BYPASS_LVL).
By default, a policer discards frames (to the affected port type: CPU and/or front port or ports) while the
policer is closed. A discarded frame is not forwarded to any ports (including the CPU).
However, each port policer has the option to run in flow control where the policer instead of discarding
frames instructs the MAC to issue flow control pause frames
(ANA_AC_POL:POL_ALL_CFG:POL_PORT_FC_CFG.FC_ENA). When operating in Flow control mode
it is possible to specify a hysteresis, which controls when the policer can re-open after having closed
(ANA_AC_POL:POL_PORT_CFG:POL_PORT_THRES_CFG_1. PORT_THRES1). The current flow
control state is accessible (ANA_AC_POL:POL_ALL_CFG:POL_PORT_FC_CFG.FC_STATE).
Note: Flow control signaling out of ANA_AC must be enabled
(ANA_AC_POL::POL_ALL_CFG.PORT_FC_ENA).
To improve fairness between small and large frames being policed by the same policer a hysteresis can
be specified for drop mode (ANA_AC_POL:POL_PORT_CFG:
POL_PORT_THRES_CFG_1.PORT_THRES1), which controls when the policer can re-open after
having closed. By setting it to a value larger than the maximum transmission unit, it can be guaranteed
that when the policer opens again, all frames have the same chance of being accepted.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
195
Functional Descriptions
Port policers can be configured operate on logical ports instead of physical ports
(ANA_AC_POL::POL_ALL_CFG.LPORT_POLICE_ENA) and thereby allow policing of aggregated port
bandwidth.
Traffic dropped by a policer can be counted by the port statistic block.
The following port policer debug events are available.
•
•
•
•
•
•
•
3.21.2.7
Bypass of policer due to pipeline handling can be identified
(ANA_AC_POL:POL_ALL_CFG:POL_STICKY.POL_PORT_PT_BYPASS_STICKY).
Bypass of policer due to DP bypass level can be identified
(ANA_AC_POL:POL_ALL_CFG:POL_STICKY.POL_PORT_BYPASS_STICKY).
Dropping of traffic towards CPU due to policer can be identified
(ANA_AC_POL:POL_ALL_CFG:POL_STICKY.POL_PORT_DROP_CPU_STICKY).
Dropping of traffic towards front port due to policer can be identified
(ANA_AC_POL:POL_ALL_CFG:POL_STICKY.POL_PORT_DROP_FWD_STICKY).
Policers that are active, but not closed can be identified per policer
(ANA_AC_POL:POL_ALL_CFG:POL_STICKY.POL_PORT_ACTIVE_STICKY).
Policer triggering flow control can be identified
(ANA_AC_POL:POL_ALL_CFG:POL_STICKY.POL_PORT_FC_STICKY).
Policer leaving flow control state can be identified
(ANA_AC_POL:POL_ALL_CFG:POL_STICKY.POL_PORT_FC_CLEAR_STICKY).
Storm Policing
Each storm policer entry contains the fields in the following table. The fields are all located within the
ANA_AC_POL:POL_ALL_CFG register group.
Table 134 • Storm Policer Table Entry
Field
Bits
Description
STORM_TRAFFIC_TYPE_MASK
8
Configures the traffic types to be taken into account by the policer.
STORM_FRAME_RATE_ENA
1
Configures frame rate mode for the ACL policer, where rates are
measured in frames per second instead of bytes per second.
STORM_LIMIT_NONCPU_TRAFFIC_ENA 1
Configures how policing affects traffic towards front ports.
STORM_LIMIT_CPU_TRAFFIC_ENA
1
Configures how policing affects traffic towards CPU.
STORM_CPU_QU_MASK
8
Configures policing of frames to the individual CPU queues for the
port policer (see TRAFFIC_TYPE_MASK).
STORM_GAP_VALUE
7
Configures the leaky bucket calculation to include or exclude
preamble, inter-frame gap and optional encapsulation through
configuration
STORM_THRES
6
Configures storm policer burst capacity.
STORM_RATE
17
Configures storm policer rate.
Frames applicable for policing are any frame received by the MAC and forwarded to the classifier. Short
frames (less than 148 bytes) with errors, pause frames, or MAC control frames are not forwarded by the
MAC and therefore not accounted for in the policers. That is, they are not policed and do not add to the
rate measured by the policers.
Storm policers are enabled by configuring the traffic type to be policed
(POL_STORM_CTRL.STORM_TRAFFIC_TYPE_MASK) and specifying a corresponding rate
(POL_STORM_RATE_CFG.STORM_RATE).
The policer burst capacity can be specified with 4K granularity (POL_STORM_THRES_CFG).
Policing of traffic destined for CPU port or ports can be controlled
(POL_STORM_CTRL.STORM_TRAFFIC_TYPE_MASK(7) = 0 and CPU bypass mask in
POL_STORM_CTRL.STORM_CPU_QU_MASK).
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
196
Functional Descriptions
Storm policers can be configured individually to affect frames towards CPU ports
(POL_STORM_CTRL.STORM_LIMIT_CPU_TRAFFIC_ENA) or front ports
(POL_STORM_CTRL.STORM_LIMIT_NONCPU_TRAFFIC_ENA).
The following parameters can also be configured per policer.
•
•
Leaky bucket calculation can be configured to include or exclude preamble, inter-frame gap, and an
optional encapsulation (POL_ALL_CFG.STORM_GAP_VALUE).
Each policer can be configured to measure frame rates instead of bit rates
(POL_STORM_CTRL.STORM_FRAME_RATE_ENA).
Traffic dropped by a storm policer can be counted by the port statistic block.
The following storm policer debug events are available.
•
•
•
3.21.3
Dropping of traffic towards CPU due to policer can be identified
(POL_STICKY.POL_STORM_DROP_CPU_STICKY).
Dropping of traffic towards front port due to policer can be identified
(POL_STICKY.POL_STORM_DROP_FWD_STICKY).
Policers that are active, but not closed, can be identified per policer
(POL_STICKY.POL_STORM_ACTIVE_STICKY).
Analyzer Statistics
This section describes how to configure and collect statistics. There are six statistics counter blocks in
the analyzer:
•
•
•
•
•
•
Port statistics: Eight 40-bit counters are available for each port.
Queue statistics: Two 40-bit counters are available for each queue.
BUM policer statistics: Six 40-bit counters are available for each BUM policer.
ACL policer statistics: Two 40-bit counters are available for each ACL policer.
Ingress router leg statistics: Eight IPv4 40-bit counters and eight IPv6 40-bit counters are available
for each ingress router leg.
Egress router leg statistics: Eight IPv4 40-bit counters and eight IPv6 40-bit counters are available
for each egress router leg.
Counters can be set up to count frames or bytes based on configurable criteria. This is described in the
following sections.
3.21.3.1
Port Statistics
The following table lists the applicable port statistics registers.
Table 135 • Analyzer Port Statistics Register Overview
Target::Register.Field
Description
Replication
ANA_AC:STAT_GLOBAL_CFG_PORT.
STAT_GLOBAL_EVENT_MASK
Configures global event mask per counter. 8
ANA_AC:STAT_GLOBAL_CFG_PORT:STAT_RESET Initializes or resets all statistic counters and 1
.RESET
the sticky bits.
ANA_AC:STAT_CNT_CFG_PORT.STAT_CFG.
CFG_PRIO_MASK
Configures counting of frames with certain
priorities.
per port × 8
ANA_AC:STAT_CNT_CFG_PORT.STAT_CFG.
CFG_CNT_FRM_TYPE
Configures the frame type to be counted.
per port× 8
ANA_AC:STAT_CNT_CFG_PORT.STAT_CFG.
CFG_CNT_BYTE
Configures counting of bytes or frames.
per port × 8
ANA_AC:STAT_CNT_CFG_PORT.STAT_LSB_CNT
Least significant 32 bits.
per port × 8
ANA_AC:STAT_CNT_CFG_PORT.STAT_MSB_CNT
Most significant 8 bits.
per port × 8
ANA_AC:STAT_CNT_CFG_PORT.STAT_EVENTS_S Sticky bits for counter events.
TICKY
per port
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
197
Functional Descriptions
The port statistics block allows counting of a wide variety of frame events. These are represented by a
12-bit event mask:
•
•
•
Bits 0–3 represent any stick bit contribution from preceding blocks in ANA.
Bits 4–7 represent port policer events.
Bits 8–11 represent storm and ACL policer events and loopback frames.
The propagation of the event mask from the preceding blocks in the analyzer to ANA_AC is shown in the
following illustration, except for bits 8–11. See
ANA_AC:STAT_GLOBAL_CFG_PORT:STAT_GLOBAL_EVENT_MASK.GLOBAL_EVENT_MASK.
Figure 37 • Sticky Events Available as Global Events
ANA_CL
*_sticky
*_sticky_mask(0)
*_sticky_mask(1)
*_sticky_mask(2)
*_sticky_mask(3)
ANA_L3
ANA_L2
*_sticky
*_sticky
*_sticky_mask(0)
*_sticky_mask(1)
*_sticky_mask(2)
*_sticky_mask(3)
*_sticky_mask(0)
*_sticky_mask(1)
*_sticky_mask(2)
*_sticky_mask(3)
ANA_AC
*_sticky
*_sticky_mask(0)
*_sticky_mask(1)
*_sticky_mask(2)
*_sticky_mask(3)
Port
Policer
global events[7:0]
The global events [3:0] are typically allocated for detected control frames, frames dropped due to wrong
configuration, frames dropped due to VLAN filtering, and so on.
As an example, a particular event that is normally only of interest during debug, ANA_L2:
STICKY.VLAN_IGNORE_STICKY can be configured to be the global event 0 in
ANA_L2:STICKY_MASK.VLAN_IGNORE_STICKY_MASK(0).
The following illustration shows the configuration and status available for each port statistics counter.
Figure 38 • Port Statistics Counters
t7
cn
CF
G_
P
ST RIO
AT
_
_ M MA
SB SK
_C
CF
NT
G_
CN
ST
T
AT _BY
_L
T
SB E
_C
NT
cn
t0
cn
t1
Port_num
Before the statistic counters can be used, they must be initialized to clear all counter values and sticky
bits (ANA_AC:STAT_GLOBAL_CFG_PORT:STAT_RESET.RESET).
For each counter, the type of frames that are counted must be configured
(ANA_AC:STAT_CNT_CFG_PORT.STAT_CFG.CFG_CNT_FRM_TYPE).
Note: Frames without any destination are seen by the port statistics block as aborted.
Each counter must be configured if bytes or frames are counted
(ANA_AC:STAT_CNT_CFG_PORT.STAT_CFG.CFG_CNT_BYTE).
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
198
Functional Descriptions
It is possible to limit counting to certain priorities
(ANA_AC:STAT_CNT_CFG_PORT.STAT_CFG.CFG_PRIO_MASK).
Counter events that can trigger counting can be selected among the global events
(ANA_AC:STAT_GLOBAL_CFG_PORT. STAT_GLOBAL_EVENT_MASK). There is one common event
mask for each of the four counter sets.
Each 40-bit counter consists of an MSB part and an LSB part (ANA_AC:STAT_CNT_CFG_PORT.
STAT_MSB_CNT and ANA_AC:STAT_CNT_CFG_PORT.STAT_LSB_CNT). The MSB part of the
counter is latched to a shadow register when the LSB part is read. As a result, the LSB part must always
be read first, and the MSB part must be read immediately after the LSB part. When writing to the counter,
the LSB part must be written first, followed by the MSB part.
The following pseudo code shows the port statistics functionality.
for (port_counter_idx = 0; port_counter_idx < 8; port_counter_idx++) {
if
(STAT_CNT_CFG_PORT[frame.igr_port].STAT_CFG[port_counter_idx].CFG_PRIO_MASK[
frame.prio]) {
count = FALSE;
global_event_mask =
STAT_GLOBAL_EVENT_MASK[port_counter_idx].GLOBAL_EVENT_MASK;
event_match =(STAT_GLOBAL_EVENT_MASK[port_counter_idx].GLOBAL_EVENT_MASK &
frame.event_mask);
switch
(STAT_CNT_CFG_PORT[frame.igr_port].STAT_CFG[port_counter_idx].CFG_CNT_FRM_TY
PE) {
case 0x0:
if (!frame.error && !event_match) count = 1;
break;
case 0x1:
if (!frame.error && event_match) count = 1;
break;
case 0x2:
if (frame.error && event_match) count = 1;
break;
case 0x3:
if (event_match) count = 1;
break;
case 0x4:
if (frame.error && !event_match) count = 1;
break;
case 0x5:
if (frame.error) count = 1;
break;
}
if (count) {
if
(STAT_CNT_CFG_PORT[frame.igr_port].STAT_CFG[port_counter_idx].CFG_CNT_BYTE) {
STAT_xSB_CNT[port_counter_idx] += frame.bytes;
} else {
STAT_xSB_CNT[port_counter_idx]++;
}
}
}
}
Example: To set up port counter 3 to count bytes filtered by VLAN ingress filter, the following
configuration is required.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
199
Functional Descriptions
•
•
•
•
Enable VLAN drop events as global event 3:
Set
ANA_L3:L3_STICKY_MASK:VLAN_MSTP_STICKY_MASK[3].VLAN_IGR_FILTER_STICKY_MAS
K = 1.
Initialize counters:
Set ANA_AC:STAT_GLOBAL_CFG_PORT:STAT_RESET.RESET = 1.
Set up port counters. For each active Ethernet port:
Set ANA_AC:STAT_CNT_CFG_PORT[port].STAT_CFG[3].CFG_CNT_FRM_TYPE = 3.
Set ANA_AC:STAT_CNT_CFG_PORT[port].STAT_CFG[3].CFG_CNT_BYTE = 1.
Set ANA_AC:STAT_CNT_CFG_PORT[port].STAT_CFG[3].CFG_PRIO_MASK = 0xFF.
Enable global event 3 as trigger:
Set ANA_AC:STAT_GLOBAL_CFG_PORT[3]. STAT_GLOBAL_EVENT_MASK = 8.
Example: To set up port counter 0 to count frames dropped by port policer, the following configuration is
required.
•
•
3.21.3.2
Set up port counters. For each active Ethernet port:
Set ANA_AC:STAT_CNT_CFG_PORT[port].STAT_CFG[0].CFG_CNT_FRM_TYPE = 3.
Set ANA_AC:STAT_CNT_CFG_PORT[port].STAT_CFG[0].CFG_CNT_BYTE = 0.
Set ANA_AC:STAT_CNT_CFG_PORT[port].STAT_CFG[0].CFG_PRIO_MASK = 0xFF.
Enable global event 4 to 7 as trigger:
Set ANA_AC:STAT_GLOBAL_CFG_PORT[0]. STAT_GLOBAL_EVENT_MASK = 0xF0.
Queue Statistics
The following table lists the applicable queue statistics registers.
Table 136 • Queue Statistics Registers Overview
Target::Register.Field
Description
Replication
ANA_AC:STAT_GLOBAL_CFG_QUEUE:
STAT_GLOBAL_CFG
Configures counting of bytes or frames per
queue (= port × 8 + iprio).
2
ANA_AC:STAT_GLOBAL_CFG_QUEUE:
STAT_GLOBAL_EVENT_MASK
Configures global event mask per queue
(= port × 8 + iprio).
2
ANA_AC:STAT_CNT_CFG_QUEUE.STAT_LSB_ Least significant 32 bits of counters per queue. per queue × 2
CNT
ANA_AC:STAT_CNT_CFG_QUEUE.STAT_MSB Most significant 8 bits of counters per queue.
_CNT
per queue × 2
The following illustration shows the configuration and status available for each queue statistics counter.
Figure 39 • Queue Statistics
CN
T
LS
B_
ST
AT
_
ST
AT
_
M
SB
_C
NT
cn
t0
cn
t1
index = port number *8 + IPRIO
Each counter type must be configured to count either bytes or frames
(ANA_AC:STAT_GLOBAL_CFG_QUEUE: STAT_GLOBAL_CFG.CFG_CNT_BYTE).
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
200
Functional Descriptions
ACL events that can trigger counting can be selected among the following events:
•
•
Count traffic applicable for queue policer, but not discarded
Count traffic discarded by queue policer
There is one common event mask for each of the two queue counter types
(ANA_AC:STAT_GLOBAL_CFG_QUEUE:STAT_GLOBAL_EVENT_MASK).
Each 40-bit counter consists of an MSB part and an LSB part
(ANA_AC:STAT_CNT_CFG_QUEUE.STAT_MSB_CNT and
ANA_AC:STAT_CNT_CFG_QUEUE.STAT_LSB_CNT). The MSB part of the counter is latched to a
shadow register, when the LSB part is read. As a result, the LSB part must always be read first, and the
MSB part must be read immediately after the LSB part. When writing to the counter, the MSB part must
be written first, followed by the LSB part.
3.21.3.3
Broadcast, Unicast, Multicast (BUM) Policer Statistics
The following table lists the applicable BUM policer statistics registers.
Table 137 • BUM Policer Statistics Registers Overview
Target::Register.Field
Description
ANA_AC:STAT_GLOBAL_CFG_BUM:
STAT_GLOBAL_CFG
Configures counting bytes or frames per BUM policer index. 2
Replication
ANA_AC:STAT_GLOBAL_CFG_BUM:
STAT_GLOBAL_EVENT_MASK
Configures global event mask per BUM policer index.
2
ANA_AC:STAT_CNT_CFG_BUM.STAT_ Least significant 32 bits of counters per BUM policer index. per BUM
LSB_CNT
policer index
×2
ANA_AC:STAT_CNT_CFG_BUM.STAT_ Most significant 8 bits of counters per BUM policer index.
MSB_CNT
per BUM
policer index
×2
The following illustration shows the configuration and status available for each BUM policer.
Figure 40 • BUM Policer Statistics
SB
_C
N
T
T
AT
_M
ST
ST
AT
_L
SB
_C
N
t
cn 4
t
5
cn
t
cn 0
t
1
cn
Index =
ANA_L3:VLAN:BUM_CFG.BUM_SLB_IDX
or
ANA_L2:ISDX:MISC_CFG.BUM_SLB_IDX
Set of six counters per
BUM policer
Each of the two counters in a counter set can be configured to which frames are counted and whether
bytes or frames are counted. This configuration is shared among all counter sets.
The BUM event mask supports counting the following frame types:
•
•
•
•
•
•
Broadcast traffic discarded by BUM policer
Multicast traffic discarded by BUM policer
Unicast traffic discarded by BUM policer
Broadcast traffic applicable for BUM policer, but not discarded
Multicast traffic applicable for BUM policer, but not discarded
Unicast traffic applicable for BUM policer, but not discarded
The event mask is configured in ANA_AC:STAT_GLOBAL_CFG_BUM:STAT_GLOBAL_EVENT_MASK.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
201
Functional Descriptions
Each 40-bit counter consists of an MSB part and an LSB part
(ANA_AC:STAT_CNT_CFG_BUM.STAT_MSB_CNT and ANA_AC:STAT_CNT_CFG_
BUM.STAT_LSB_CNT). The MSB part of the counter is latched to a shadow register when the LSB part
is read. As a result, the LSB part must always be read first, and the MSB part must be read immediately
after the LSB part. When writing to the counter, the MSB part must be written first, followed by the LSB
part.
3.21.3.4
ACL Policer Statistics
The following table lists the applicable ACL policer statistics registers.
Table 138 • ACL Policer Statistics Registers Overview
Target::Register.Field
Description
Replication
ANA_AC:STAT_GLOBAL_CFG_ACL:
STAT_GLOBAL_CFG
Configures counting of bytes or frames per ACL policer
index.
2
ANA_AC:STAT_GLOBAL_CFG_ACL:
STAT_GLOBAL_EVENT_MASK
Configures global event mask per ACL policer index.
2
ANA_AC:STAT_CNT_CFG_ACL.STAT_ Least significant 32 bits of counters per ACL policer index. per ACL policer
LSB_CNT
index × 2
ANA_AC:STAT_CNT_CFG_ACL.STAT_ Most significant 8 bits of counters per ACL policer index.
MSB_CNT
per ACL policer
index × 2
The following illustration shows the configuration and status available for each ACL policer statistics
counter.
Figure 41 • ACL Policer Statistics
_C
NT
ST
AT
_L
SB
B_
CN
T
ST
AT
_M
S
cn
t0
cn
t1
index = VCAP_S2.POLICE_IDX
Each counter type must be configured whether bytes or frames are counted
(ANA_AC:STAT_GLOBAL_CFG_ACL: STAT_GLOBAL_CFG.CFG_CNT_BYTE).
ACL events that can trigger counting can be selected among the following events. ACL events that can
trigger counting can be selected among the following events. If an ACL policer is triggered by an IS2
action, with IS_INNER_ACL = 1, it is termed “inner”. Otherwise, it is termed “outer”.
•
•
•
•
•
•
•
•
Count CPU traffic applicable for outer ACL policer, but not discarded
Count front port traffic applicable for outer ACL policer, but not discarded
Count CPU traffic discarded by outer ACL policer
Count front port traffic discarded by outer ACL policer
Count CPU traffic applicable for inner ACL policer, but not discarded
Count front port traffic applicable for inner ACL policer, but not discarded
Count CPU traffic discarded by inner ACL policer
Count front port traffic discarded by inner ACL policer
There is one common event mask for each of the two ACL policer counter types
(ANA_AC:STAT_GLOBAL_CFG_ACL:STAT_GLOBAL_EVENT_MASK).
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
202
Functional Descriptions
Each 40-bit counter consists of an MSB part and an LSB part
(ANA_AC:STAT_CNT_CFG_ACL.STAT_MSB_CNT and
ANA_AC:STAT_CNT_CFG_ACL.STAT_LSB_CNT). The MSB part of the counter is latched to a shadow
register when the LSB part is read. As a result, the LSB part must always be read first, and the MSB part
must be read immediately after the LSB part. When writing to the counter, the MSB part must be written
first, followed by the LSB part.
3.21.3.5
Routing Statistics
The following table lists the applicable routing statistics registers.
Table 139 • Analyzer Routing Statistics Registers Overview
Target::Register.Field
Description
Replication
ANA_AC:STAT_GLOBAL_CFG_IRLEG:
STAT_GLOBAL_CFG
Configures counting of bytes or frames per ingress
router leg counter.
8
ANA_AC:STAT_GLOBAL_CFG_IRLEG:
STAT_GLOBAL_EVENT_MASK
Configures global event mask per ingress router leg
counter.
8
ANA_AC:STAT_CNT_CFG_IRLEG.STAT_ Least significant 32 bits of ingress router leg counters. Per RLEG per
LSB_CNT
IP_version × 8
ANA_AC:STAT_CNT_CFG_IRLEG.STAT_ Most significant 8 bits of ingress router leg counters.
MSB_CNT
Per RLEG per
IP_version × 8
ANA_AC:STAT_GLOBAL_CFG_ERLEG:
STAT_GLOBAL_CFG
Configures counting of bytes or frames per egress
router leg counter.
8
ANA_AC:STAT_GLOBAL_CFG_ERLEG:
STAT_GLOBAL_EVENT_MASK
Configures global event mask per egress router leg
counter.
8
ANA_AC:STAT_CNT_CFG_ERLEG.STAT_ Least significant 32 bits of egress router leg counters.
LSB_CNT
Per RLEG per
IP_version × 8
ANA_AC:STAT_CNT_CFG_ERLEG.STAT_ Most significant 8 bits of egress router leg counters.
MSB_CNT
Per RLEG per
IP_version × 8
The following illustration shows the configuration and status available for ingress router leg and egress
router leg statistics counter sets. For these devices, RLEG_CNT is 128.
Figure 42 • Ingress and Egress Routing Statistics per Router Leg per IP Version
ERLEG Statistics
IPv6 entries
IPv6 entries
7
cn
t
CN
T
SB
_
_C
NT
SB
7
cn
t
cn
t
0
cn
t
1
ST
AT
_M
ST
AT
_M
SB
ST
_C
AT
NT
_L
SB
_C
NT
IPv4 entries
index = erleg when IPv4
index = erleg+RLEG_CNT when IPv6
ST
AT
_L
IPv4 entries
cn
t
0
cn
t
1
index = irleg when IPv4
index = irleg+RLEG_CNT when IPv6
IRLEG Statistics
Each counter type must be configured to count either bytes or frames.
(ANA_AC:STAT_GLOBAL_CFG_IRLEG: STAT_GLOBAL_CFG.CFG_CNT_BYTE and
ANA_AC:STAT_GLOBAL_CFG_ERLEG: STAT_GLOBAL_CFG.CFG_CNT_BYTE)
Ingress router leg counter events that can trigger counting can be selected among the following events:
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
203
Functional Descriptions
•
•
•
•
•
•
•
acl_discarded - frame applicable for routing but discarded due to VCAP IS2 ingress discard action
(first VCAP IS2 lookup with action RT_ENA cleared).
received IP unicast traffic - frame applicable for routing (hitting a router leg).
received IP multicast traffic - frame applicable for routing (hitting a router leg).
unicast_routed - frame is unicast routed.
multicast_routed - frame is multicast routed
ip_multicast_rpf_discarded - frame discarded due to failed Reverse Path Forwarding check (frame
not received from configured interface)
ip_TTL_discarded - frame discarded due to TTL VLAN_MIRROR_ENA set (enabled in
ANA_AC:MIRROR_PROBE[x].PROBE_CFG.PROBE_VLAN_MODE== 1).
All frames received from a known station with MAC->MIRROR set (enabled in
ANA_AC:MIRROR_PROBE[x].PROBE_CFG.PROBE_MAC_MODE(1)= 1).
All frames send to a known station with MAC->MIRROR set (enabled in
ANA_AC:MIRROR_PROBE[x].PROBE_CFG. PROBE_MAC_MODE(0) = 1). This can also be
flooded traffic (enabled via ANA_L2::FWD_CFG.FLOOD_MIRROR_ENA).
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
206
Functional Descriptions
•
•
Frames selected through configured VCAP entries (enabled by VCAP IS2 action
MIRROR_PROBE). For such frames, the only other applicable mirror criteria is
PROBE_DIRECTION.
All frames received from CPU, also known as CPU ingress mirroring (enabled in
ANA_AC:MIRROR_PROBE[x].PROBE_CFG.PROBE_DIRECTION(1) = 1 and CPU ports to be RX
mirrored set in ANA_AC:MIRROR_PROBE[x].PROBE_RX_CPU_AND_VD).
The mirror port configured per probe (QFWD:SYSTEM:FRAME_COPY_CFG[8-11]) can be any port on
the device, including the CPU.
Rx-mirrored traffic sent to the mirror port is sent as received optionally with an additional Q-tag (enabled
in REW::MIRROR_PROBE_CFG.REMOTE_MIRROR_CFG).
Tx-mirrored traffic sent to the mirror port is modified according to a configured Tx port
(REW:COMMON:MIRROR_PROBE_CFG.MIRROR_TX_PORT) optionally with an additional Q-tag
(enabled in REW::MIRROR_PROBE_CFG.REMOTE_MIRROR_CFG).
For information about possible rewriter options for mirrored frames, see Mirror Frames, page 268.
Example: Ingress port mirroring in specific VLAN
All traffic only in VLAN 3 from host B on port 3 (the probe port) is mirrored to port 11 (the mirror port)
using probe 1, as shown in the following illustration.
Figure 44 • Ingress Mirroring in Specific VLAN
Switch
2
3
4
11
VLAN 3
VLAN 2
Host A
Host B
Host C
Network Analyzer
The following configuration is required:
•
•
3.22
Enable RX mirroring on port 3:
ANA_AC:MIRROR_PROBE[1].PROBE_CFG.PROBE_DIRECTION = 2 (= Rx only)
ANA_AC:MIRROR_PROBE[1].PROBE_PORT_CFG = 0x8 (port 3)
Enable VID filtering: ANA_AC:MIRROR_PROBE[1].PROBE_CFG.PROBE_VLAN_MODE = 2 and
ANA_AC:MIRROR_PROBE[1].PROBE_CFG. PROBE_VID = 3
Shared Queue System and Hierarchical Scheduler
The devices include a shared queue system with a per-port ingress queue and 27,328 shared egress
queues. The shared queue system has 32 megabits of buffer (16 megabits in VSC7442-02 and
VSC7444-02). It receives frames from 57 ports, stores them in a shared packet memory, and transmits
them towards 57 destination ports. The first 53 of the ports are assigned directly to a specific front port,
whereas the last four ports are internal ports.
Table 142 • Port Definitions in Shared Queue System
Ports
Connection
0–48
Front port, maximum bandwidth is 1 Gbps or 2.5 Gbps.
49–52
Front port, maximum bandwidth is 10 Gbps.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
207
Functional Descriptions
Table 142 • Port Definitions in Shared Queue System (continued)
Ports
Connection
53–54
Frame injection and extraction CPU ports. The CPU connects these ports to DMA logic or a register
interface.
55
IP multicast loopback port (VD0).
Egress: When the queue system is requested to transmit to VD0, it generates multiple copies. All copies
are, outside the queue system, looped back into the analyzer. The rewriter changes the ingress port
number to VD0 before the loop. The analyzer generates a routed version of each of the frame copies
coming from port VD0.
56
AFI loopback port (VD1).
When the queue system is requested to send to VD1, it sends the request to the AFI. The AFI stores the
request and can be configured to transmit the frame to any port in a programmed schedule. The AFI can
transmit the frame to any of the egress ports. If VD1 is selected as destination by the AFI, the frame is
looped back into the analyzer.
The following illustration provides an overview of shared queue system.
Figure 45 • Shared Queue System Block Diagram
Scheduling Configuration
Egress Queues, Destination 0
Queue 0
Queue 1
Buffer Control
Analyzed
Frames
Ingress Queues
Forwarding
Queue
Mapping
Queue 0
Ref
Queue 1
Frame
Forwarder
Queue
Mapper
Analyzer
Result
Scheduler
Hierarchy
Queue n
Egress Queues, Destination 1
Queue 0
Queue
Limitation
Queue n
Data
Congestion Control
Transmit
commands
for port 0
Queue 1
Transmit
commands
for port 1
Scheduler
Hierarchy
Queue n
Egress Queues, Destination 56
Packet
Memory
Resource
Management
Transmit
commands
for port 56
Queue 0
Queue 1
Scheduler
Hierarchy
Queue n
Frames are stored in the packet memory and linked into the ingress queue for the logical source port
along with the analyzer result.
The analyzer result is then processed by a frame forwarder, frame by frame. Each of the frame
transmission requests are added to an egress queue in the queue system attached to a specific egress
port. A transmission request can be a normal switching request to another port, a mirror copy, for
stacking updates, and for a CPU connected to one of the egress ports. For VD0, it can do multiple copies
of the request. The frame forwarder can also request that a specific frame copy be discarded.
The frame forwarder is efficient, because only frame references are switched, giving a forwarding
bandwidth in the range of 100 Gbps (88byte frames) to 3 terabits (Tbps) (1,518 byte frames). The frame
data itself is not moved within the queue system.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
208
Functional Descriptions
The forwarding request is passed through a queue mapper, which then selects an egress queue based
on the classified properties of the frame. For example, a simple switch may use the classified QoS class
only and an advanced carrier switch may use MPLS-classified traffic class (TC).
A congestion control system can decide to discard some or all copies of the frame. This decision is
based on consumption per QoS level. The queue mapper can be configured to change the drop decision
using a congestion control mechanism based on queue sizes rather than only QoS class.
Each destination port has a part of the total shared queue pool attached. Transmission is scheduled
towards the destination ports through a hierarchical scheduling system, where all queues belonging to
each port are arbitrated. On the way out, frames pass through the rewriter where the frame data can be
modified due to, for instance, routing, MPLS encapsulation, or tagging. The queue system does not
change the original frame data.
An ingress port operates in one of three basic modes: drop mode, port flow control, or priority-based flow
control. The following table lists the modes and flow definitions.
Table 143 • Ingress Port Modes
Mode
Flow
Drop mode (DROP)
The link partner is unaware of congestion and all frames received by the port are evaluated
by the congestion control function where copies of the frame can be discarded.
Port flow control (FC)
The link partner is informed through pause frames (full-duplex) or collisions (half-duplex)
that the port cannot accept more data. If the link partner obeys the pause requests, no
incoming data is discarded by the port. If the pause frames are disobeyed by the link
partner, the buffer control function in the queue system discards data before it reaches the
ingress queues.
Priority-based flow
control (PFC)
The link partner is informed about which QoS classes in the queue system are congested
and the link partner should stop scheduling more frames belonging to these QoS classes. If
the pause frames are disobeyed by the link partner, the buffer control function in the queue
system discards data before it reaches the ingress queues.
3.22.1
Analyzer Result
The analyzer provides required information for switching frames in the shared queue system. The
following table lists the information provided and a general description of the purpose.
Table 144 • Analyzer Result
Group
Field
Function
Destination selection
Destination set
Set of ports to receive a normal switched copy.
Destination selection
CPU queue mask
Set of CPU queues to receive a copy.
Destination selection
Mirror
Requests mirror copy.
Destination selection
Learn all
Requests learn copy to stack ports.
Congestion control
Drop mode
This particular frame can be dropped even if ingress port is setup for
flow control.
Congestion control
DP
Drop precedence level
Congestion control
Priorities
Ingress resource priority of the frame. Four classified classes are
provided from the analyzer: QoS, PCP, COSID, and TC. All values
between 0 and 7.
Queue mapping
SP
Super priority frame
Queue mapping
QGRP
Queue group for service-based egress queuing.
Statistics
OAM type
Service counters can be configured to only count certain OAM frame
types.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
209
Functional Descriptions
3.22.2
Buffer Control
Frames are stored in a shared packet memory bank, which contains 23,826 words (11,913 words in
VSC7442-02 and VSC7444-02) of 176 bytes each. A memory manager controls which words the packet
writer uses to store a frame.
With proper configuration, the packet memory bank always has a free word available for incoming
frames. There are configurable thresholds for triggering pause frame requests on ports enabled for flow
control and for discarding frames due to too large memory use when for instance pause frames are
disobeyed by the link partner.
Frames discarded at this stage are discarded without considering the frame’s destination ports. This kind
of discarding is called tail dropping. It is an indication of head-of-line blocking and is not usually desired.
For information about how it can be avoided by proper configuration of the congestion control system,
see Congestion Control, page 213.
The pause frame and discard mechanisms are activated when a threshold for the individual port’s
memory use is reached and when a threshold for the total use of memory is reached.
The following table lists the configuration registers involved in the buffer control.
Table 145 • Buffer Control Registers Overview
Register
Description
Replication
QSYS::ATOP
Maximum allowed memory use for a port before tail dropping is
activated.
Per port
QSYS::ATOP_TOT_CFG
Total memory use before tail dropping can be activated.
None
QSYS::PAUSE_CFG
Thresholds for when to start and stop port flow control based on
memory use by the port.
Per port
QSYS::PAUSE_TOT_CFG
Total memory use before flow control is activated.
None
QFWD::SWITCH_PORT_MODE
Enable drop mode for a port.
Per port
The following table lists available status information.
Table 146 • Buffer Status Registers Overview
Register
Description
Replication
QSYS::MMGT_PORT_USE
Current consumption for a specific port
None
QSYS::MMGT_PORT_VIEW
Selection of port to show usage for
None
QSYS::MMGT
Number of free words in packet memory
None
3.22.3
Forwarding
The frame forwarder processes frames at the head of the per-port ingress queues by adding references
to the egress queues for each of the frames’ destination ports. The references points from the egress
queues to the stored frames. The forwarder can add from 125 million to 250 million references per
second.
The ingress queues are selected by a weighted round-robin search, where the weights are configured in
QFWD::SWITCH_PORT_MODE.FWD_URGENCY.
Each frame is processed as either a drop-mode frame or a flow control frame, which influences how the
congestion control works. For a drop-mode frame, the congestion control can discard frame copies while
for a flow control frame, it lets the frame stay at the head of the ingress queue blocking further processing
of frames from the port until the congestion situation is over. A frame is processed as a drop-mode frame
if one of the following conditions is met:
•
•
The ingress port is configured to be an ingress drop port.
The egress port is configured to be an egress drop port.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
210
Functional Descriptions
•
The frame itself is analyzed to be a drop frame.
In terms of discarding frames, the forwarder can work in an ingress-focused statistics mode or an egressfocused statistics mode. The mode is configured per ingress port in XQS::STAT_CNT_CFG.
In the ingress-focused mode, a frame can be discarded towards multiple destinations simultaneously.
The discard statistics is only incremented if the frame is discarded towards all destinations.
In the egress-focused mode, the discard statistics is incremented for each copy of the frame being
discarded at the expense of the forwarder only discarding one frame copy per cycle. The forwarder can
therefore become oversubscribed. If, for instance, two 10G ports are broadcasting 64-byte frames at
wire-speed to ten destinations, the total amount of frame copies per second is 20 × 10
frames/(8 × (64 + 20) ns) = 297 million frames per second. The forwarder can at maximum process 250
million frames per second. As a consequence, the ingress queues fill up and tail dropping is inevitable.
If the DROP_SINGLE option is set in QFWD::FWD_CTRL, each individual copy is counted. That must be
enabled in egress focused mode, and can be enabled in ingress focused, at the expense as the above
described.
The highlights of the modes are listed in the following table.
Table 147 • Statistics Modes
Statistics Mode
Operation
Ingress-focused
A frame switched to N ports and discarded to M ports will update the discard statistics for the
ingress port by one, only if N = 0 and M >0. The forwarder will use N cycles to process the
frame.
Ingress-focused
drop-single
A frame switched to N ports and discarded to M ports will update the discard statistics for the
ingress port by M. The forwarder will use N + M cycles to process the frame.
Egress-focused
A frame switched to N ports and discarded to M ports will update the discard statistics for the M
egress ports by one. The forwarder will use N+M cycles to process the frame.
3.22.3.1
Forward Pressure
The worst-case switching capacity in the frame forwarder is 125 million frames per second. This
corresponds to 84 Gbps line rate with minimum-sized frames.
However, if a large share of these frames have multiple destinations that are all close to the 64 byte
minimum frame size, the processing speed is insufficient to process the destination copy one at a time.
The consequence is that the ingress queues start to fill. The ingress queues contain both high and low
priority traffic, unicast, and multicast frames. To avoid head-of-line blocking effects from the ingress
queues filling up and eventually leading to tail dropping, a forward pressure system is in place. It can
discard frame copies based on the size of the ingress queues. Forward pressure is configured in the
QSYS::FWD_PRESSURE registers, where each port is allowed only a certain number of copies per
frame if the number of pending transmit-requests in the port’s ingress queue exceeds a threshold.
The following table lists the registers associated with configuring forward pressure.
Table 148 • Forward Pressure Configuration Registers Overview
Register
Description
Replication
QSYS::FWD_PRESSURE.FWD_PRESSURE
Configures forwarding pressure limits per port.
Per port
QSYS::MMGT_IQ_STAT
Returns current ingress queue size.
Per port
QFWD::FWD_PRESSURE.FWD_PRESS_
DROP_CNT
Counts number of frame copies discarded due to this None
feature. Value is total discards for all ports in common.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
211
Functional Descriptions
3.22.3.2
Destination Selection
The forwarder adds references to the egress queues by evaluating the destination selection information
shown in the following table from the analyzer.
Table 149 • Analyzer Destination Selection
Field
Function
Destination set
Set of ports to receive a normal switched copy.
All ports except the internal extraction ports have a bit in this mask.
CPUQ
Set of CPU queues to receive a copy
Mirror
Request mirror copy
Learn-all
Request learn copy to stack ports
The destination set selects specific egress ports and the CPUQ, mirror, and learn-all fields are indirect
frame destinations and must be translated to transmit requests through the frame copy configuration
table. The table provides a specific egress port and QoS class to use in congestion control. The table is
accessed through the QFWD::FRAME_COPY_CFG register.
The following illustration shows the translation of transmit requests.
Figure 46 • Translation of Transmit Requests
Egress ports from destination set
CPU queues
Mirror request
Translate
requests to
egress ports
Egress ports
LearnAll request
The CPUQ field instructs which of the eight CPU extraction queues should get a copy of this frame. Each
queue in the queue system is translated into either one of the two internal CPU ports or to a front port.
The egress QoS class can be set to the same value as the ingress QoS class or to a specific value per
CPU extraction queue. A super priority can also be used. For more information, see Super Priorities,
page 229.
The mirror field is the mirror probe number, which is set by the analyzer if the frame must be mirrored.
There are three mirror probes available, and for each of the probes, associated egress port and egress
QoS class can be set by the translation table.
Finally, if the learn-all field is set, the frame should also be forwarded to the stacking links. It is selectable
to forward the frame to either of the two stacking links or to both, depending on the stacking topology.
The following table lists the configuration registers associated with the forwarding function.
Table 150 • Frame Forwarder Registers Overview
Register
Description
Replication
QFWD::SWITCH_PORT_MODE
Enables forwarding to/from port.
Forwarding speed configuration.
Drop mode setting.
Per port
QFWD::FRAME_COPY_CFG
Translates CPUQ/mirror/learn all to enqueuing requests.
12
QFWD::FRAME_COPY_LRNA_CFG
Learn All frame copy extra port.
None
QFWD::CPUQ_DISCARD
Disables enqueuing to specific CPU queues.
None
QSYS::FWD_PRESSURE
Configures forwarding pressure limits per port.
Per port
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
212
Functional Descriptions
Table 150 • Frame Forwarder Registers Overview (continued)
Register
Description
QFWD::MIRROR_CFG
Configures whether discarded copies should still generate a None
mirror copy.
3.22.4
Replication
Congestion Control
The buffer control can only guarantee that no ingress port consumes more than a certain amount of
memory. Discards made by the buffer control are tail drops. The congestion control is more advanced in
that it facilitates intelligent discard where only frames belonging to a congested flow are discarded.
If the forwarder finds that some frame copies are made to a congested flow, it discards the copies (dropmode frames) or lets the copies block further processing of the ingress queue (flow control ports).
The congestion control information from the analyzer result involved in the congestion control is listed in
the following table.
Table 151 • Analyzer Congestion Results
Field
Function
Drop mode
This frame can be dropped even if port is setup for flow control. This function is mainly used by the
analyzer for stacking use where the ingress unit's source port determines how congestion should
be handled.
DP
Drop precedence level. A value 0-3, telling how yellow the frame is.
QoS class
Frame's ingress QoS class
The current consumption of resources in the congestion controller is updated when a reference is added
to one of the egress queues. The congestion controller tracks four different resources:
•
•
•
•
Ingress packet memory consumption. Each frame uses a number of 176-byte words.
Egress packet memory consumption. Each frame uses a number of 176-byte words.
Ingress frame reference consumption. Each frame uses one frame reference per frame copy.
Egress frame reference consumption. Each uses one frame reference per frame copy.
There are 23,826 memory words and 23,826 frame references in total (11,913 memory words and 11,913
frame references in VSC7442-02 and VSC7444-02).
The accounting is done based on QoS classes and port numbers. Each account has a threshold
associated specifying how many resources the account is permitted to consume. The accounts are as
follows:
•
•
•
•
Consumption per port per QoS class. This is a reservation account.
Consumption per port. A frame does not consume resources from this account before the resources
belonging to the previous account are consumed. This is a reservation account.
Consumption per QoS class. A frame does not consume resources from this account before the
resources belonging to the previous two accounts are consumed. This is a sharing account.
Consumption in addition to the above. A frame does not consume from this account before the
resources belonging to the previous three accounts are consumed. This is a sharing account.
The congestion controller updates an accounting sheet with the listed accounts for each of the tracked
resources.
The following illustration shows reservation accounts for the packet memory accounting sheets when a
700-byte frame from port 0 forwarded to ports 1 and 5 with QoS class 2 is added. The frame size
requires the use of five words in the packet memory. The account for ingress port 0, QoS class 2 is
reserved three words. Before the frame is added, it is checked if the account was fully utilized. If the
account was not fully used, the frame is allowed into the queue system. After the frame is added, the
account is updated with the five words and therefore uses two more than was reserved. These are
consumed from the port account. The port account is reserved 0 words and the added two words
therefore also close the port account. This affects further frame reception.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
213
Functional Descriptions
In the egress side, there are no words reserved for the account per port per QoS class. The port account
for port 1 is 8 words and 0 words for port 5.
Figure 47 • Accounting Sheet Example
Packet memory, egress user
Packet memory, ingress user
Priority
0 1 2 3 4 5 6 7 P
Priority
0 1 2 3 4 5 6 7 P
Port
Port
5
3
0
2
0
0
1
1
...
...
...
5
...
...
5
0
5
8
5
0
5
0
For PFC purposes, the congestion controller contains an additional accounting sheet of the ingress
memory consumption. The sheet has its own set of thresholds. The result of the accounting is whether to
send PFC pause frames towards the link partner.
The combined rule for allowing a frame copy is if both of the following are true:
•
•
Either ingress or egress memory evaluation must allow the frame copy.
Either the ingress or egress reference evaluation must allow the frame copy.
When the reserved accounts are closed, the shared accounts spanning multiple ports are checked.
Various rules for regarding these accounts as open or closed exist. These rules are explained in the
following through three major resource modes, which the congestion controller is intended to be used in.
Figure 48 • Reserved and Shared Resource Overview
Sh
ar
ed
Re
so
ur
ce
Packet Memory
Port 1
prio 0
prio 1
prio 2
prio 3
prio 0
prio 1
prio 2
prio 3
prio 4
prio 5
prio 6
prio 7
prio 5
prio 6
prio 7
Egress
Reservation
Port 0
prio 4
Port 1
prio 0
prio 1
prio 2
prio 3
prio 4
prio 5
prio 6
prio 7
prio 5
prio 6
prio 7
Ingress
Reservation
Port 0
prio 0
prio 1
prio 2
prio 3
prio 4
The resource modes are defined by the way the shared resources are distributed between classes of
frames. Note, that there are many options for configuring different resource mode than the modes
described in the following. This is outside the scope of this document.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
214
Functional Descriptions
3.22.4.1
Strict Priority Sharing
This resource mode considers higher QoS classes as more important than lower QoS classes. The
shared area is one big pool shared between all QoS classes. Eight thresholds define the limit for each of
the eight QoS classes. If the total consumption by all QoS classes exceeds one of the thresholds, the
account associated with the particular QoS class is closed.
Figure 49 • Strict Priority Sharing
QoS class 7 limit
QoS class 5 limit
QoS class 4 limit
QoS class 3 limit
QoS class 2 limit
Sh
rce
ou
s
Re
ed
ar
QoS class 1 limit
Consumption
QoS class 6 limit
QoS class 0 limit
One important property of this mode is that higher QoS classes can block lower QoS classes. A
congested flow with a high QoS class uses all of the shared resources up to its threshold setting and
frame with lower QoS classes are thus affected (lower burst capacity).
The following table shows the configuration settings for strict priority sharing mode.
Table 152 • Strict Priority Sharing Configuration Settings
Configuration
Setting
Reservation thresholds
These can be set to any desired value. The amount set aside for each account
should be subtracted from the overall resource size, before the sharing thresholds
are set up.
Ingress QoS class thresholds
Levels at which each QoS class should start to reject further enqueuing. Frames
with multiple destinations are only accounted once because they are physically only
stored once.
Ingress color thresholds
Set to their maximum value to disable. The color is not considered in this mode.
WRED group memberships
Disable all.
Egress sharing thresholds
Set all to 0, because only use ingress sharing control is . Egress would account for
multiple copies, which is not intended.
QoS reservation
(QRES::RES_QOS_MODE)
Disable for all. No shared resources are set aside per QoS class.
3.22.4.2
Per Priority Sharing
This mode sets aside some memory for each QoS class and can in addition have an amount of memory
reserved for green traffic only. This mode operates on ingress resources, in order to utilize that frames
with multiple destinations are only stored once.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
215
Functional Descriptions
Figure 50 • Per Priority Sharing
r ce
QoS class 6
e so u
QoS class 5
QoS class 4
QoS class 3
QoS class 2
QoS class 1
QoS class 0
ed R
S har
QoS class 7
DP=0 limit
DP=1 limit
DP=2 limit
DP=3 limit
The following table shows the configuration settings for per priority sharing mode.
Table 153 • Per Priority Sharing Configuration Settings
Configuration
Setting
Reservation thresholds
These can be set to any desired value, except for ingress per port reservation. The
algorithm requires these to be zeroed.
Ingress QoS class thresholds
Set to amount of shared memory which should be set aside for each QoS class. The
sum of all these should not exceed the amount of memory left after all the
reservations has been subtracted.
Ingress color thresholds
Subtracting all reservations including QoS class shared areas may end up in some
unused memory. Set the color thresholds to various levels to guarantee more space
the greener.
WRED group memberships
Disable all.
Egress sharing thresholds
Set all to 0, as we only use ingress sharing control. Egress would account for
multiple copies, which is not intended.
QoS reservation
(QRES::RES_QOS_MODE)
Enable for all.
3.22.4.3
Weighted Random Early Discard (WRED) Sharing
In this mode, the shared resource accounts close at random. A high consumption gives a high probability
of discarding a frame. This sharing method only operates on the egress memory consumption.
There are three WRED groups, each having a number of ports assigned to it. Each WRED group
contains 24 WRED profiles; one per QoS class per DP = 1, 2, 3. Each WRED profile defines a threshold
for drop probability 0% and a threshold for drop probability 100%. Frames with DP = 0 value are
considered green and have no WRED profile. Green frames should always be allowed.
Memory consumptions within a WRED group are tracked per QoS class.
The WRED groups with each eight QoS classes are shown in the following illustration. It is also possible
to use fewer groups or different sizes for each QoS classes.
Figure 51 • WRED Sharing
WRED Group 0
WRED Group 1
QoS class 7
QoS class 6
QoS class 5
QoS class 4
QoS class 3
QoS class 2
QoS class 1
QoS class 0
QoS class 7
QoS class 6
rce
QoS class 4
QoS class 3
QoS class 2
QoS class 1
QoS class 0
QoS class 7
QoS class 6
QoS class 5
QoS class 4
QoS class 3
QoS class 2
QoS class 1
QoS class 0
s ou
e d re
S h ar
QoS class 5
DP = 0 limit
WRED Group 2
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
216
Functional Descriptions
The following illustration shows an example of the WRED profiles for a QoS class within a WRED group.
Thresholds are shown for DP = 2 only.
Figure 52 • WRED Profiles
Drop probability
D
W
M
_R
_
ED
P=
LO
3
D
P=
2
100%
DP=
W
W
M
_R
E
H
D_
IG
1
H
WRED group
consumption for
QoS class
The WRED sharing is operating as an egress algorithm. The following table shows the configuration
setting.
Table 154 • WRED Sharing Configuration
Configuration
Setting
Reservation thresholds
These can be set to any desired value, except for ingress per port reservation. The
algorithm requires these to be zeroed.
Ingress priority thresholds
Set to their maximum value, as the QoS classes should not have any sharing across
WRED groups.
Ingress color thresholds
Set to their maximum.
WRED group memberships
Set to define the WRED groups. For each group, define as well the up to 24 WRED
profiles (per QoS class and DP level)
Egress sharing thresholds
Set the QoS class thresholds to the highest possible consumption before any profile
hits 100% probability. The color thresholds can then operate on the remainder of the
resource in control and can all be set to the same value, allowing use of all the
remaining. A discard due to the WRED profile takes precedence over other sharing
states, so the area outside the group sections is only available for green traffic.
QoS reservation
(QRES::RES_QOS_MODE)
Disable for all.
3.22.4.4
Priority-Based Flow Control
There is a fifth accounting scheme for the pending frames. It operates on ingress memory use, but has
the same set of thresholds as the other account systems. The output from that system is however not
used for stopping/discarding frame copies, but for requesting the port to transmit pause flow control
frames for the involved priorities. The threshold levels here should be configured in a way so that the
blocking thresholds cannot be reached during the trailing amount of data.
3.22.4.5
Threshold Configuration
There are a large number of thresholds for the reservations described. They are all found in the
QRES::RES_CFG register, which is replicated 5,120 times:
Table 155 • Threshold Configuration Overview
QRES::RES_CFG Replication Description
0–455
Ingress memory reservation for port P priority Q accessed at index 8P+Q.
496–503
Ingress memory shared priority threshold for priority Q accessed at index 496+Q.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
217
Functional Descriptions
Table 155 • Threshold Configuration Overview (continued)
QRES::RES_CFG Replication Description
508–511
Ingress memory shared threshold for DP levels 1, 2, 3, and 0.
512–568
Ingress memory reservation for port P, shared between priorities, accessed at index
512+P.
1,024–2,047
Ingress reference thresholds. Same organization as for ingress memory, but added
offset 1,024.
2,048–3,071
Egress memory thresholds. Same organization as for ingress memory, but added
offset 2048.
3,072–4,095
Egress reference thresholds. Same organization as for ingress memory, but added
offset 3,072.
4,096–5,119
PFC memory thresholds, operating on ingress memory use. PFC is activated when
no memory left according to these thresholds. Same organization as the ingress
stop thresholds, but added offset 4,096.
The following table lists other registers involved in congestion control.
Table 156 • Congestion Control Registers Overview
Register
Description
QRES::RES_STAT (replicated same
way as RES_CFG)
Returns maximum value the corresponding threshold has been compared
with.
QRES::RES_STAT_CUR (replicated
as RES_CFG)
Returns current value this threshold is being compared with.
QRES::WRED_PROFILE (72 profiles) Profile description. 3 (grp) × 3 (DP) × 8 (prio) profiles exist.
QRES::WRED_GROUP
WRED group membership configuration per port.
QRES::PFC_CFG
Enable PFC per port.
QRES::RES_QOS_MODE
Enable QoS reservation for QoS classes.
QFWD::SWITCH_PORT_MODE
Controls whether yellow traffic can use reserved space (YEL_RSVD). Allows
ports to use shared space (IGR_NO_SHARING, EGR_NO_SHARING).
3.22.4.6
Frame Forwarder Monitoring
The performance of the frame forwarder can be monitored through the registers listed in the following
table.
Table 157 • Frame Forwarder Monitoring Registers Overview
Register
Description
XQS::FWD_DROP_EVENTS
Sticky bits per port telling if drops from each individual ingress port occurred.
XQS::FWD_CPU_DROP_CNT
Counts number of frames not forwarded to the CPU due to congestion.
XQS::FWD_STAT_CNT
Counts number of frame copies added to the egress queues in total.
QFWD::FWD_PRESS_DROP_CNT
Counts number of frame copies discarded due to forward pressure. Value is
the total discards across all ports.
QSYS::MMGT_IQ_STAT
Returns current ingress queue size.
QSYS::MMGT
Returns number of free references for the egress queues.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
218
Functional Descriptions
3.22.5
Queue Mapping
When a frame is forwarded to an egress port, a frame reference is inserted into one of the port’s egress
queues. The egress queues are read by a programmable scheduler consisting of a number of scheduler
elements (SEs). Each SE serves 8 or 64 queues, configurable through the HSCH::HSCH_LARGE_ENA
registers. Each SE selects the next input to transmit and forwards the decision to a next-layer SE,
selecting from which of its inputs to transmit. There are a total of three layers, with layer 0 being the
queue connected layer. Connections between the layers are fully configurable in HSCH::L0_CFG and
HSCH::L1_CFG. For more information about SE functionality, see Scheduling, page 224 and Bandwidth
Control, page 226.
The scheduler includes a dual leaky bucket shaper to limit the traffic rate from inputs attached to it. To
distribute the bandwidth between the inputs, the scheduler also contains a weighted round robin arbiter.
The number of queues available in total for all ports is 27,328. The queue mapper must be configured to
how these queues are assigned to each egress port. The overall traffic management for each port is the
result of the queue mapping and scheduler hierarchy.
The following illustration shows an example of the default egress port hierarchy. At layer 0, eight SEs
select between data in the same QoS level, with queues from each source port. This forms a basic traffic
manager, where all source ports are treated fair between each other, and higher priorities are preferred.
This is accomplished by having the layer 0 SEs select input in a round robin fashion, and the mid-layer
select strictly higher inputs before lower inputs. In general, all SEs can be configured to various polices
on how to select inputs.
The illustration also shows the two super-priority queues available in all ports. The scheduler hierarchy
configuration must be based on a desired scheme. The hardware default setup is providing a queue per
(source, priority) per egress port. All queues with the same QoS level are arbitrated first, in layer 0.
Figure 53 • Scheduler Hierarchy (Normal Scheduling Mode)
src 0, iprio 0
src 1, iprio 0
Scheduler
Element
Su
pe
r
src , iprio 0
pr
io
r
pe
Su
1
io
pr
src 0, iprio 1
0
src 1, iprio 1
Scheduler
Element
Scheduler
Element
Scheduler
Element
Transmit
Requests
src , iprio 1
src 0, iprio 7
src 1, iprio 7
Scheduler
Element
src 56, iprio 7
3.22.5.1
Mapping System
All queues in the system are referred to as a layer 0 SE number and an input number. For example, the
default configuration puts all traffic for port 0 from source 7 in priority 0 into the queue (0,7); SE number 0,
input 7. When the forwarder requests a frame to be added to a queue, the queue group—all classified
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
219
Functional Descriptions
priorities, the source port, and the destination port—are used to find the SE and input on it, through some
configurable mapping tables. There are three basic hierarchy types, and the first part of the mapping
procedure is to find the hierarchy type in XQS::QMAP_PORT_MODE. The mode is found for frames with
classified qgrp = 0 in the QMAP_MODE_NONSERVICE field and in QMAP_MODE_SERVICE for qgrp
>0. Note that service and non-service mappings can be combined at the higher layers, in order to
combine the two basic types of traffic in the application. An overview of the queue mapping tables is
shown in the following illustration. The drop statistics mode is also found by looking up information in
these tables. For more information, see Statistics, page 229.
Figure 54 • Queue Mapping Tables
QoS
TC
PCP
COSID
dst port
VPORT Table
sel
QoS Table
qgrp
qc_
qc
vport
Map Mode
src port
Input number
SE Table
SE number
drop_stat_ctrl
cos_sel
cos8_ena
QoS
TC
PCP
COSID
oam_cnt_sel
base_addr
val 0-7
address
Ingress
Service Stat
add
res
s
frm
oct
Mapping is accomplished by the following steps.
1.
2.
Finding virtual port (vport). Used only for looking up fields in other tables.
vport = QMAP_VPORT_TBL (qgrp,dport)
Find queuing class (qc_cl)
qc_sel = QMAP_QOS_TBL (vport)
qc = (qos, cosid, pcp, tc) (qc_sel)
Find queue. This mapping depends on which of the following hierarchy modes are configured:
Mode 0: Normal mode. This is the default mode on all ports. It is used for arbitrating all frames with the
same queuing class, treating all source ports equally.
SE = QMAP_SE_TBL (vport + qc), inp = source port.
Mode 1: Group mode. This mode is used for having eight queues per queue group in layer 0. Used in
Carrier applications where each service should have its own queues, with a traffic profile per queuing
class.
SE = QMAP_SE_TBL (vport), inp = qc.
The following illustration shows the group scheduling mode.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
220
Functional Descriptions
Figure 55 • Group Scheduling Mode
qgrp 0, qos 0
qgrp 0, qos 1
Scheduler
Element
Su
pe
qgrp n, qos 7
r
pr
io
1
r
pe
Su
Scheduler
Element
pr
io
qgrp 1, cos 0
0
qgrp 1, cos 1
Scheduler
Element
Scheduler
Element
Transmit
Requests
qgrp n, cos 7
Scheduler
Element
qgrp 17, cos 0
qgrp 17, cos 1
Scheduler
Element
qgrp n, cos 7
Mode 2: Microwave Backhaul (MBH) mode. This mode is used when many queue groups need to be
arbitrated per queuing class, and they share a common outgoing quality of service policy. For example, it
may be possible to have 768 queues per queuing class arbitrated on level 0 and 1, and class selected on
level 2. In this case, the SE table is used by SE = QMAP_SE_TBL (vport + qc), Inp = qgrp MOD 64.
The following illustration shows the Mobile Backhaul mode.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
221
Functional Descriptions
Figure 56 • Mobile Backhaul Mode
qgrp 0, qos 0
qgrp 1, qos 0
Scheduler
Element
Su
pe
r
qgrp 63, qos 0
pr
io
1
r
pe
Su
Scheduler
Element
io
pr
qgrp 704, qos 0
0
qgrp 705, qos 0
Scheduler
Element
Scheduler
Element
Transmit
Requests
qgrp 767, qos 0
Scheduler
Element
qgrp 704, qos 7
qgrp 705, qos 7
Scheduler
Element
qgrp 767, qos 7
The following table lists the registers associated with assigning queues for each egress port.
Table 158 • Queue Mapping Registers Overview
Configuration
Description
QMAP_PORT_MODE
Selects queue layer hierarchy type
QMAP_VPORT_TBL1
Map (qgrp,dport) into a virtual port
QMAP_QOS_TBL1
Selects per vport from which queueing QoS it should be derived
QMAP_SE_TBL1
Selects per vport a scheduling element
1.
The QMAP_xx_TBLs are indirectly accessed by setting the target index in
XQS:MAP_CFG_CFG.MAP_CFG_CFG following read or write to replication 0 of the register.
3.22.5.2
Service Statistics
As shown in the following illustration, drop statistics configuration is also being looked up in the mapping
flow. The device has 8,192 service counter sets. On the ingress side, the queue system only counts
discarded frames. On the egress side, it counts the amount of frames transmitted. In both cases, there is
a counter for green frames and another counter for yellow frames.
The egress counter set to count is selected through the rewriter. The ingress counter is selected by
looking up drop statistics information when the queuing class is looked up. That returns a base index,
which is multiplied by four, and one of the four classified priority parameters is added. If the set is
configured for using only four counters, the MSB of the priority is cleared. The resulting index will
afterwards be counting drops, with 18 bits of octet counting, and 10 bits of frame counting. Optionally, all
28 bits can be used for frame counting. For more information about drop statistics, see Statistics,
page 297.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
222
Functional Descriptions
3.22.6
Queue Congestion Control
The congestion control system may choose to forward a frame to a specific queue or to discard it. In
either case, the decision passes through a queue limitation function, which can alter the decision based
on another view of the resources
The following illustration shows the drop decision flow.
Figure 57 • Drop Decision Flow
Transmit or
discard frame
copy to a
specific port
Frame
Forwarder
Transmit or
discard frame
copy to a
specific queue
Queue
Mapper
Transmit frame
copy to a
specific queue
or skip request
Queue
Limitation
Scheduler
The queue limitation function checks the queue size against various configurable and dynamic values
and may change a transmit request to a discard by canceling the request to the scheduler.
A port can also be configured for being in minimum mode, in which case, the queue limiter can change a
discard request to a transmit request.
The queue limitation system uses queue sizes (in terms of packet memory usage) of all queues. Each
queue is assigned to a share. The share is a configuration parameter for the port to which the queue
belongs, as set in the QLIMIT_PORT_CFG register. A set of watermarks is afterwards used to control
some queue limitation drop mechanisms, trying to discard data for congested queues without affecting
well-balanced traffic.
The conditions under which a frame is discarded is shown in the following illustration The watermarks
shown are defined per shared account and per color. If yellow traffic is present, it can be discarded fairly
without affecting the green traffic.
Figure 58 • Queue Limitation Share
Discard all
QLIMIT_SHR_TOP
Discard if SE looks congested
QLIMIT_SHR_ATOP
Discard if SE looks congested
and if queue looks congested
QLIMIT_SHR_CTOP
Discard if SE consumes
too much and if queue consumes
too much
QLIMIT_SHR_QLIM
Queue size sum
No frame discarding
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
223
Functional Descriptions
The following table provides descriptions of the queue limitation conditions.
Table 159 • Queue Limitation Conditions
State
Description
Traffic Condition
SE looks congested
The total size of queues into the layer-0 SE The data on the specific SE is looking like
exceeds the QLIMIT_SE_CONG
growing, and the SE seems to receive
watermark.
more data than it has been granted
egress bandwidth. When the filling gets
very high, further data into that SE can be
discarded.
Queue looks congested
The queue size exceeds the watermark in
QLIMIT_QUE_CONG.
The queue seems to be growing. When
the share filling is high, it can be chosen to
discard further data into the queue.
SE consumes too much
The total SE use exceeds the dynamic fair
share, which is the QLIMIT_SHR_QDIV
watermark divided by the number of SEs
looking congested. This division result is
called DYN_WM.
There is a number of SEs in the scheduler
building up data, and this particular SE is
using more than the fair share of the
buffer. Frames are discarded in the effort
to grant equal burst capacities to all SEs
seeking intermediate buffer.
Queue consumes too much The queue size exceeds DYN_WM, which
is the QLIMIT_SHR_CTOP watermark
divided by the number of queues looking
congested.
The queue seems to be one of the
reasons for the growing memory
consumption, and further additions to the
queue can be avoided.
The following table lists the queue limitation registers.
Table 160 • Queue Limitation Registers
Register Groups
Description
QLIMIT_QUEUE1
Reads current queue size.
QLIMIT_SE1
Reads current SE queue sum and congestion count.
QLIMIT_PORT
Assigns ports to shares. Configures minimum mode.
QLIMIT_SHR
Configures watermarks for share and monitor filling and dynamic watermarks.
QLIMIT_MON
Reads the status for each of the logical shares.
1.
3.22.7
The QLIMIT_QUEUE registers are indirectly accessed by setting the target index in
XQS:MAP_CFG_CFG.MAP_CFG_CFG following the read or write to replication 0 of the register.
Scheduling
All egress queues are combined in a tree structure where the root is connected to an egress port. The
scheduling capabilities consist of the following three aspects.
•
•
•
3.22.7.1
Structure of the hierarchy
Bandwidth limitation (shaping)
Bandwidth distribution (arbitration between inputs)
Hierarchy Structure
The hierarchy consists of three layers: queue, middle, and outer.
•
Layer 0 is the queue level. All inputs to scheduler elements are connected to a specific egress
queue, as described in the previous section. This layer has 3,400 elements with eight inputs each. A
number of those can be reconfigured to have 64 inputs, in which case they are called “large
elements”. Only elements in multiples of eight can become large, so the seven following can not be
used.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
224
Functional Descriptions
•
•
Layer 1 is the middle layer. There are 64 elements in this layer, all having 64 inputs. These inputs
are connected to outputs of the layer 0 elements, through the HSCH::L0_CFG table.
Layer 2 is the output layer. There is one scheduler element per egress port (57 elements). All
elements have 64 inputs connected to outputs from layer 1 elements. Input n on the layer 2
elements can only be connected to layer 1 element n, configured in HSCH::L1_CFG.
If the hierarchy needs are simple, Layer 1 can be bypassed to save SE resources for other ports by
setting an output connection from a layer 0 element to 63, input n, in which case the output from that
element will be connected to input 63 of layer 2 element n.
3.22.7.2
Default Hierarchy
The initialization engine in the scheduler builds a default hierarchy for all ports, and no further
configuration of it is needed. It sets all ports into normal mode, using eight large elements on layer 0, and
one element on each of the two other layers. The layer 0 elements are all configured for frame based
round robin selection, and the layer 1 elements for strict selection of highest available input.
Port n uses elements 64n, 64n + 8, 64n + 16, ... for layer 0. The example in the following illustration is for
port 7.
Figure 59 • Default Scheduling Hierarchy
layer 0
layer 1
layer 2
SE
#448
SE
#456
SE
#464
57 queues, src x,
dst 7, iprio 3
SE
#472
SE #7
SE #7
SE
#480
SE
#488
SE
#496
SE
#504
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
225
Functional Descriptions
3.22.7.3
Bandwidth Control
Each scheduler element has a dual leaky bucket shaper on its output, which may block further
transmissions from that scheduler element. It is controlled through a leaky bucket system, filling the
bucket when data is transmitted and leaking it at the configured rate. The bucket is closed when more
data than the configured burst capacity has been filled into it.
The shaper has three rate modes that define what is added to a bucket:
•
•
•
Bits transmitted excluding IFG
Bits transmitted including IFG
Frames transmitted
Each of the three layers have four linked lists configured. All scheduling elements with active shapers
must be members of one of those. Each linked list is processed once every configurable interval. When a
list is processed, all shapers in it will leak its configured rate setting.
Examples:
•
•
Data rate shapers are connected in a linked list, which is traversed every 10 µs. The shaper rate
granularity becomes 100 kbps.
Frame rate shapers are connected in a linked list, which is traversed every 1 ms. The shaper rate
granularity becomes 1 kilo frames per second.
Each scheduler element includes two leaky buckets to support DLB shaping. The committed information
rate (CIR) bucket is open when the filling is below the configured limit. The excess information rate (EIR)
shaper is always closed, unless the congestion control reports that a threshold is reached. Which
congestion thresholds to react on are configurable for each shaper and should depend on the traffic
groups the particular element is a part of. The effect of the DLB shaper is that the rate out of the shaper
is CIR or CIR plus EIR, depending of the accumulation of data in the queue system.
The following table lists the registers associated with shaping.
Table 161 • Shaper Registers Overview
3.22.7.4
Register
Description
HSCH::SE_CFG
Selects filling mode
HSCH::CIR_CFG
Configures leak rate and burst capacity for CIR bucket
HSCH::EIR_CFG
Configures leak rate and burst capacity for EIR bucket
HSCH::SE_DLB_SENSE
Selects thresholds to control EIR with.
HSCH::HSCH_LEAK_LIST
Configures leak list periods and starting index
HSCH::SE_CONNECT
Links to next in leaking lists
HSCH::CIR_STATE
Returns current CIR bucket filling
HSCH::EIR_STATE
Returns current EIR bucket filling
HSCH::SE_STATE
Returns whether or not the shaper is open
Bandwidth Distribution
Each scheduler element selects one of its inputs as the next source of transmission if a scheduling
process passes through it. A number of different options are available for how this arbitration takes place.
A configured value for the scheduler element tells how many of the lower indexed inputs should be
arbitrated with the DWRR method. Inputs with higher indexes are preferred and arbitrated strict.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
226
Functional Descriptions
Figure 60 • Scheduler
0
DWRR
Strict
63
The lower indexes are arbitrated in the effort to achieve a bandwidth ratio between them. In this regard,
the bandwidth can be measured in frames, data bits, or line bits (including IFG). Each input is configured
with a cost setting, and the algorithm strives to give n times more bandwidth to input A than B, if the cost
configuration for A is n times lower than B.
Example: Input 4 has cost 7, and input 6 has cost 11. If the total bandwidth shaped out of the scheduler
element is 180 Mbps, input 4 will get the 110 Mbps of it.
Example: All inputs have cost 1, and the element is configured for frames per second arbitration.
Algorithm will by this strive to send an equal number of frames from each input.
Configuring costs is done indirectly by setting the HSCH_CFG_CFG.DWRR_IDX first (pointing to the
scheduler element to configure), after which the costs are accessible through the HSCH_DWRR
registers.
The following table lists the registers associated with the arbitration algorithm.
Table 162 • Scheduler Arbitration Registers Overview
Register
Description
HSCH::SE_CFG
Selects arbitration mode (data/line/frame) and number of inputs running DWRR
HSCH::CFG_CFG
Selects for which element to configure/monitor DWRR algorithm
HSCH::DWRR_ENTRY
Configures costs for each input
HSCH::INP_STATE
Returns input states for a scheduler element
3.22.7.5
Queue Shapers
In addition to the shaping capabilities at the output of each scheduling element, it is also possible to
shape individual queues. These shapers are single leaky bucket based. The devices contain 6,800 such
shapers that can be assigned to any of the 27,328 queues. The assignment of queue shapers is done
through the HSCH::QSHP_ALLOC_CFG register. This is replicated per scheduling elements in layer 0,
and defines the range of inputs on the element that should have queue shapers assigned, and the index
of the first of the 6800 shapers to allocate to it. The shapers must be linked together for the leaking
process in HSCH::QSHP_CONNECT
For example, to configure queue shapers on inputs 5 to 7 on elements 100 to 120, use the queue
shapers from 400 to 462.
For I in 100 to 120 loop
HSCH:QSHP_ALLOC_CFG[I]:QSHP_ALLOC_CFG.QSHP_MIN := 5
HSCH:QSHP_ALLOC_CFG[I]:QSHP_ALLOC_CFG.QSHP_MAX := 7
HSCH:QSHP_ALLOC_CFG[I]:QSHP_ALLOC_CFG.QSHP_BASE := 3*(I-100)+400
HSCH:QSHP_ALLOC_CFG[I]:QSHP_CONNECT.SE_LEAK_LINK := I+1;
Endloop
(terminate chain)
HSCH:QSHP_ALLOC_CFG[120]:QSHP_CONNECT.SE_LEAK_LINK := 120
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
227
Functional Descriptions
The leak process operates as for the SE shapers and must be configured in
HSCH:HSCH_LEAK_LISTS[3].
The indexes of shapers allocated to a set of queues are only used in the QSHP_BASE settings. The
shapers are accessed afterwards through the QSHP_CFG and QSHP_STATUS registers, accessed
indirectly after setting HSCH_CFG_CFG.CFG_SE_IDX to the desired scheduling element.
For example, to configure the shaper on input 6 of element 118 to shape to 1.2 Mbps, set
HSCH::HSCH_CFG_CFG.CFG_SE_IDX := 118 and HSCH:QSHP_CFG[6].QSHP_CIR_CFG.CIR_RATE
:= 12 (assuming the leak chain is configured for unit 100 kbps).
3.22.7.6
Miscellaneous Scheduler Features
The following table lists some features that might be useful.
Table 163 • Miscellaneous Scheduler Registers Overview
Field
Description
SE_CONNECT_VLD
Stops the whole scheduler operation. Can be useful when reconfiguring the hierarchy.
LEAK_DIS
Disable leaking process.
FRM_ADJ
Sets the byte difference between line and data rate calculations.
DEQUEUE_DIS
Disables transmissions per port.
3.22.8
Queue System Initialization
The queue system automatically initializes all tables and data structures when setting
RAM_CTRL.RAM_ENA to 1, followed by setting RAM_CTRL.RAM_INIT to 1. Software should
afterwards wait for 150 µs or wait for the RAM_INIT bit to be cleared by hardware. After that the
RESET_CFG.CORE_ENA must be raised, and the queue system is ready to operate. All thresholds and
queue mappings are prepared with operational values. Configuration can afterwards be modified. The
only per-port setting required to change in the queue system for initial bring-up of the queue system is
the SWITCH_PORT_MODE.PORT_ENA, which must be set to one allowing switching of frames to and
from the port.
3.22.9
Miscellaneous Features
This section provides information about other miscellaneous features of the queue system.
3.22.9.1
Frame Aging
The queue system supports discarding of frames pending in the queue system for too long time. This is
known as frame aging. The frame aging period is configured in FRM_AGING.MAX_AGE, which controls
the generation of a periodical aging tick.
The packet memory manager marks frames pending in the queue system when the aging tick occurs.
Frames pending for more than two aging ticks are subject to frame aging and are discarded by the queue
system when scheduled for transmission. As a consequence, frames can be discarded after pending
between one or two aging periods in the queue system.
The following table lists the configuration registers associated with frame aging.
Table 164 • Frame Aging Registers Overview
Field
Description
Replication
QSYS::FRM_AGING.MAX_AGE
Sets the aging period
None
HSCH::PORT_MODE.AGE_DIS
Disables aging checks per egress port
Per port
HSCH::PORT_MODE.FLUSH_ENA Regards various frames as being too old
None
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
228
Functional Descriptions
3.22.9.2
Super Priorities
There are two special queues available in each egress port: super priority queue 0 and 1. For more
information, see Figure 53, page 219. These queues are selected before any other queues. They are
intended for urgent protocol traffic injected by the CPU system. Frames in super priority queue 0
disregard the output shaper state and are not counted in the shaper’s buckets. Frames in super priority
queue 1 obey the output shaper state and are counted in the shaper’s buckets.
The following frames can be added to the super priority queues:
•
•
•
3.22.9.3
AFI injected frames: The AFI can be configured to inject into either of the super priority queues. For
more information, see Adding Injection Frame, page 244.
CPU injected frames: Frames injected with an IFH with the SP flag set are inserted into the super
priority queue as being set in the drop precedence (DP) IFH field.
CPU extracted, mirror, learn all frames: Frames subject to the translation in
QFWD::FRAME_COPY_CFG can configure use of either of the super priority queues.
Frame Modifications in the Queue System
The queue system typically passes data completely untouched from the ingress to the egress side,
except for a few special cases.
Frame copies to the CPU can be sent into the rewriter with two different priority schemes, involving
modification of the internal frame header. Either the frame takes the QoS class from the CPU extraction
queue number or it takes the QoS class from the configuration in QFWD::FRAME_COPY_CFG. This is
controlled in PORT_MODE.CPU_PRIO_MODE.
Frame copies due to learn-all stack synchronization can be truncated to 64 bytes to save bandwidth on
the line. This is enabled in HSCH::PORT_MODE.TRUNC_ENA.
3.22.9.4
Statistics
The queue system counts frame discards and successful transmissions. Each counted event updates a
counter instance, counting octets in a 40-bit counter and frames in a 32-bit counter. A frame is counted
as discarded when none of the frame’s destination ports are reached, excluding mirror and learn-all
copies. If a frame is discarded, a counter instance, per ingress port, per QoS class per color, is updated.
The color granularity here is only green or yellow, mapped from the analyzed DP value through the
QSYS::DP_MAP settings. A frame transmission is a frame leaving the queue system towards the
rewriter. In this direction, a counter instance per egress port, per QoS class per color, is updated. An
abort counter instance per egress port counts frames discarded due to frame aging, queue system
flushing, or abort requests from the rewriter.
There are statistics available per service counter index, which is provided by the analyzer for ingress
service discard statistics and from the rewriter for egress service transmission statistics. The service
counters are available per counter index, per color.
Access to the statistics is indirect. The QSYS::STAT_CFG configuration register must be set to the port
or service counter index to be accessed, and all counters related to this index can afterwards be read in
the QSYS::CNT registers. The following table lists the available port counters and how they are mapped.
Unused addresses return undefined values. In the expressions, yel = 1 for reading yellow counters and
yel = 0 for green. The mapping from classified DP to color is made in the QSYS::DP_MAP register.
The following table shows the addresses of the frame counters. The equivalent octet counters are found
at the frame counter address plus 64 for the 32 least significant bits and at the frame counter address
plus 128 for the eight most significant bits.
Table 165 • Statistics Address Mapping
Statistics Index
Event
0–15
Frames received on the port viewed. The first eight counters are for green frames, QoS
level 0 – 7. The last eight counters are for yellow frames, defined by the QSYS::DP_MAP
register.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
229
Functional Descriptions
Table 165 • Statistics Address Mapping (continued)
Statistics Index
Event
16–31
Frames dropped on the port viewed. Drops will be for the ingress port point of view or
egress, depending on the DROP_COUNT_EGRESS option. There are eight green
counters and eight yellow counters.
256–271
Transmitted frames on the port viewed. Same layout as for the receive set.
272
Transmit aborted frames for the port viewed. This can be due to aging, flushing, or abortion
decision by the rewriter.
512 + 513
Green and yellow drops for service counter viewed.
768–769
Green and yellow transmissions for service counter viewed.
The service counters are reduced in size; 10 bits for the frame part and 18 bits for the octet part.
However, STAT_CFG.STAT_SRV_PKT_ONLY can be set to use all 28 bits for frame counting.
All the counters wrap at their maximum capacity. The STAT_CFG.STAT_WRAP_DIS,
however, can be set to change the behavior to clear on read and to saturate at the
maximum value.
Tail drops done by the buffer control are accessible in the QSYS::MMGT_TAIL_DROP registers.
The following tables lists the registers associated with statistics access.
Table 166 • Statistics Registers Overview
Register
Description
Replication
XQS::STAT_CFG
Selects which counter set index to access. Clear counters.
None
XQS::CNT
Replicated register with statistics access.
1,024
XQS::DP_MAP
Maps DP levels to color.
None
Examples:
To read number of transmitted yellow frames for service counter 714:
1.
2.
Write 714 to STAT_VIEW in QSYS::STAT_CFG.
Read XQS::CNT[385].
To read number of discarded green octets with QoS class 4 on port 9:
1.
2.
3.
Write 9 to STAT_VIEW in QSYS::STAT_CFG.
Read XQS::CNT[76] for the least significant bits.
Read XQS::CNT[140] for the most significant bits.
To read number of aborted frames on port 53:
1.
2.
Write 53 to STAT_VIEW in XQS::STAT_CFG.
Read XQS::CNT[272].
To read all counters for port 19:
1.
2.
3.
3.22.9.5
Write 19 to STAT_VIEW in XQS::STAT_CFG.
Read XQS::CNT[0:15, 256:272].
Add 64 and 128 to above indices for octets.
Energy Efficient Ethernet (EEE) Control
The front ports are able to signal low power idle (LPI) towards the MACs, in case they request the PHYs
to enter low power mode. A controller in each port module assures that frames are not transmitted when
the PHYs are powered down. This controller powers the PHY down when there is nothing to transmit for
a while, and it powers up the PHY when there is either data ready for a configurable time or when the
queue system has urgent data ready requiring transmission as soon as possible.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
230
Functional Descriptions
The following table lists the registers with configuring EEE.
Table 167 • EEE Registers Overview
Register
Description
Replication
QSYS::EEE_CFG
Configures the priorities per port which should bring the port
alive as fast as possible.
Per port
QSYS::EEE_THRES Configures the amount of cells or frames pending for a priority Per port
before the port should request immediate power up.
Example: Configure the device to power up the PHYs when 10 frames are pending.
Only ports 3 through 6 should regard their data as urgent and only for priorities 6 and 7. All other data
should get transmitted when the EEE controller in the port has seen pending data for the controller
configured time.
1.
2.
3.22.9.6
Write 10 to QSYS::EEE_THRES:EEE_HIGH_FRAMES.
Write 0xC0 to QSYS::EEE_CFG[3–6]::EEE_FAST_QUEUES.
Calendar Setup
There are a number of logical ports, all needing bandwidth into and out of the queue system. This is
controlled through a calendar module that grants each port access to internal busses.
The following illustration shows an overview of the internal busses. All ports are connected to a port data
bus (taxi bus) and granted access to the chip core through a mux obeying the calendar decision.
Similarly, on the path towards the transmit interface, a mux controls which port transmits the next time.
Figure 61 • Internal Bus
Loopback VD0/VD1
TAXI_0
Front
Ports
..
.
TAXI_0
Queues
TAXI_CPU
..
.
TAXI_CPU
Front
Ports
Calendar
Algorithm
The front ports are connected to taxi busses and must be guaranteed bandwidth corresponding to their
line speed. The internal CPU ports and loopback paths can operate up to 10 Gbps (7.5 Gbps for VD0).
In any port configuration, a subset of the ports is enabled. The calendar algorithm is the central place
where bandwidth is distributed between the ports. The calendar algorithm can be controlled by two
methods: automatic or sequenced.
In the automatic calendar configuration, a configuration per port defines if the port is granted 0 Gbps,
1 Gbps, 2.5 Gbps, or 10 Gbps bandwidth. For the four internal ports, the bandwidth granted is half of
these choices. In other words, internal CPU port 1 can be granted 1.25 Gbps in bandwidth.
In the sequenced operation, a specific sequence of port numbers forms the calendar. The port sequence
controls which port is granted the cycle, per bus cycle (two system clock periods).
The algorithm mode is configured in CAL_CTRL.CAL_MODE. It is possible through this register to
program a manual sequence, to halt the calendar, and to select between sequenced and automatic
calendars.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
231
Functional Descriptions
Both calendar modes may leave some slots unallocated and therefore idle on the busses. These idle
cycles can be used for configuration access (which will wait for unused cycles) and other slow operations
in the system (MAC table scan, for example). Slots allocated for a port and not used due to lack of data to
transfer can be used by the internal ports through the HSCH::OUTB_* registers, where it is, per internal
port, configured how often it will seek granting of an unused cycle. Setting internal CPU port 0 to seek
access every eight cycles means that it can get up to one frame transfer every 64 ns, or approximately
10 Gbps.
In the ingress side, the loopback paths can use idle cycles if enabled in the assembler, which controls the
ingress mux. In the egress side, the two ports can use idle slots if enabled by the calendar configuration.
Port 55 (IP multicasting), in this case, takes precedence if both loopback ports are ready to transmit.
The following table list the registers associated with configuring the calendar function.
Table 168 • Calendar Registers Overview
Register
Description
CAL_CTRL
Calendar function mode. Configures auto-grant rate.
OUTB_SHARE_ENA
Enables granting unused bus cycles to the internal ports (CPU and
VD) on the egress side.
OUTB_CPU_SHARE_ENA Configures bandwidth sharing between the two internal CPU ports.
3.23
CAL_SEQ
Interface to the sequence memory. See register list.
CAL_AUTO
Per port setting with requested bus bandwidth.
Automatic Frame Injector
The automatic frame injector (AFI) provides mechanisms for periodic injection of PDUs such as 1588
PDUs.
The following blocks are involved in frame injection.
•
•
•
•
•
QSYS. The frames are sent into the queue system by the CPU and stored in the queue system until
deleted by software.
AFI. Using timers and other parameters, AFI controls the automatic frame injection.
REW. For outbound data path injections, the REW performs frame modifications.
Loopback path. The loopback path (VD1) between the disassembler and assembler is used to inject
frames into the inbound data path.
ANA. For inbound data path injections, the ANA performs modifications of frames.
AFI supports two types of automatic frame injection: timer triggered (TTI) and delay triggered (DTI).
•
Timer Triggered Injection (TTI). Frame injection rate is controlled by timers with typical values of
approximately 3 ms or higher. Only single-frame injections are supported; injection of sequences of
frames is not supported.
For each frame, jitter can be enabled for the associated injection timer.
•
Timer triggered injection can be combined with delay triggered injection.
Delay Triggered Injection (DTI). A sequence of frames, including configurable delay between
frames, is injected.
Delay triggered injection can be combined with TTI, such that DTI is used to inject a (high)
background load (imitating normal user traffic), and TTI is used to inject OAM PDUs for measuring
IR, FLR, FTD, and FDV.
AFI supports up to 32 active DTI frame sequences at a time.
3.23.1
Injection Tables
The main tables used to configure frame injection are frame table, DTI table, and TTI table.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
232
Functional Descriptions
Injection frames for both TTI and DTI are configured in the frame table. The frame table itself does not
hold the frame, but rather a pointer to where the frame is located in the buffer memory within QSYS.
For DTI, frames can be configured into a linked list of frames to be injected. Each frame in the linked list
may be configured to be injected multiple times before proceeding with the next frame in the chain. Each
frame in the sequence is followed by one or more delay entries, specifying the delay between injections.
Timers for each TTI frame are configured in the TTI table. TTIs are always single frame injections, so the
inj_cnt and next_ptr fields in the frame table are unused for TTI. Delay entries are not used for TTI.
The TTI calendar controls the frequency with which different parts of the TTI table are serviced.
Figure 62 • Injection Tables
Delay Triggered Injection of
sequence of 5 frames on port 13
Injection Frame Table
DTI Table
first_frm_ptr
port_num ena
...
13
1
...
32 entries
inj_cnt next_ptr
3
Second frame. To be injected 3 times.
TTI Ticks
7
6
5
4
3
2
1
0
Delay
...
1
First frame of OoS injection frame sequence
4K entries
...
n/a
n/a
TTI Table
Timer configuration
frm_ptr tick_idx tick_cnt
Delay
jitter
port_num
...
Delay between the 3 injections of previous frame in
chain.
...
Base Tick
end_ptr
11
1
TTI Calendar
Fifth and last frame.
Delay
...
0
n/a
n/a
4K entries
...
3.23.2
4 calendar
slots
start_ptr
7
Frame Table
The following table lists the registers associated with configuring parameters for each entry in the frame
table.
Table 169 • Frame Table Entry Register Overview (4,096 entries)
Register
Field
Description
FRM_NEXT_AND_TYPE
NEXT_PTR
Next entry in table. Does not apply for TTI.
FRM_NEXT_AND_TYPE
ENTRY_TYPE
Entry type: Frame or Delay entry. Does not apply for TTI.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
233
Functional Descriptions
Table 169 • Frame Table Entry Register Overview (4,096 entries) (continued)
Register
Field
Description
ENTRY_TYPE=Frame
FRM_ENTRY_PART0
INJ_CNT
Number of times to inject frame. Does not apply for TTI.
FRM_RM
Frame removal. See Removing Injection Frames, page 245.
FRM_GONE
Frame removal.
FRM_INFO
Frame information. See MISC:NEW_FRM_INFO.FRM_INFO.
DELAY
Delay between injection of start of frames. Unit is one system
clock cycle. Does not apply for TTI.
ENTRY_TYPE=Delay
FRM_ENTRY_PART0
3.23.3
Delay Triggered Injection
Delay triggered injection supports up to 32 flows at a time. For each DTI flow, the DTI table holds a
pointer to a sequence of frames and delay entries, as well as the queue and port number, into which the
frames are injected. The NEXT_PTR field of the frame table is used to link frames and delay entries
together into a sequence. The frame sequence can have any length, only limited by the size of the frame
table.
Each DTI sequence can be configured to be injected repeatedly until stopped, or injected a specified
number of times. For example, if the frame sequence consists of five frames with INJ_CNT = 1, and the
sequence is configured to be injected 1000 times, then a total of 5000 frames will be injected.
DTI can be used in conjunction with TTI, for example, using TTI to inject OAM PDUs for measuring
performance metrics of the service.
The following table lists the registers associated with configuring the parameters for each of the 32
entries in the DTI table.
Table 170 • DTI Table Entry Registers Overview
Register
Field
Description
Replication
DTI_MODE
MODE
Mode of DTI instance.
Per DTI
DTI_MODE
TRAILING_DELAY_ Only applies “trailing delay” for every Nth sequence injection. Per DTI
SEQ_CNT
See Fine Tuning Bandwidth of Multiframe Sequence, page 236.
DTI_FRM
FIRST_FRM_PTR
Pointer to first frame in frame sequence.
Per DTI
DTI_FRM
NEXT_FRM_PTR
Pointer to next frame in frame sequence.
Per DTI
DTI_CNT
CNT
Counter (mode dependent).
Per DTI
DTI_PORT_QU PORT_NUM
Port number on which injection queue transmits.
Per DTI
DTI_PORT_QU SE_IDX
Injection queue. See Injection Queues, page 244.
Per DTI
DTI_PORT_QU SE_INP
Injection queue.
Per DTI
Table 171 • Miscellaneous DTI Parameters
Register
Field
Description
Replication
DTI_CTRL
BW
Bandwidth of DTI flow
0: =5 Gbps
Per DTI
DTI_CTRL
ENA
Enables DTI
Per DTI
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
234
Functional Descriptions
Frame entries in a DTI sequence may point to the same frame in the queue system’s buffer memory. For
example, shown in the following illustration, frame A and frame B shown may point to the same frame in
the buffer memory.
The delay entries in a DTI sequence must be configured such that they are longer than the transmission
time (given the port speed) of the preceding frame in the sequence.
If a DTI sequence is configured with two consecutive frame entries, then these will be injected with a
minimum delay of approximately 14 clock cycles.
3.23.3.1
Frame-Delay Sequence
A DTI flow typically consists of a sequence of alternating frame/delay entries in the frame table. If a given
frame is to be injected multiple times (FRM_ENTRY_PART0.INJ_CNT>1), then the delay of the following
entry in the sequence is applied after each injection. If additional delay is required after the last injection,
then this can be achieved by an additional delay entry. The use of delay entries is shown in the following
illustration.
DTI Frame/Delay Sequence Example
Figure 63 •
Inserted after each
injection of Frame B.
Inserted after last injection of
Frame B.
DTI
Frame C
INJ_CNT=1
NEXT_PTR
Delay
DELAY=200
NEXT_PTR
Delay
DELAY=100
NEXT_PTR
Frame B
INJ_CNT=2
NEXT_PTR
Delay
DELAY=150
NEXT_PTR
Frame A
INJ_CNT=2
NEXT_PTR
FIRST_PTR
Delay
DELAY=125
NEXT_PTR=0
Resulting frame sequence:
Frame A
Frame A
150
3.23.3.2
Frame B
150
100
Frame B
Frame C
100 + 200 = 300
125
Frame A
...
Time
Bandwidth Fine Tuning
The combination of INJ_CNT and two following delay entries can be used to fine tune the rate generated
by a DTI flow. This is shown in the following illustration, where a small delay after the four injections of
frame A is used to fine tune the rate of the DTI flow.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
235
Functional Descriptions
Figure 64 • Fine Tuning Bandwidth of DTI Sequence
Fine tune bandwidth
of DTI sequence.
DTI
NEXT_PTR
Frame A
INJ_CNT=4
NEXT_PTR
FIRST_PTR
Delay
DELAY=150
Delay
DELAY=3
NEXT_PTR=0
Resulting frame sequence:
Frame A
Frame A
150
Frame A
Frame A
150
150
...
Frame A
150
3
Time
By combining the setting of INJ_CNT and the DELAY value of the last delay depicted, the bandwidth of
the DTI sequence can be controlled with high granularity, because the additional (blue) delay will only be
applied for every INJ_CNT injections of frame A.
The bandwidth adjustment mechanism shown may be insufficient for controlling the bandwidth of multiframe sequences (sequences with different frames), because the last delay will be applied for every
injection of the frame sequence.
3.23.3.3
Fine Tuning Bandwidth of Multiframe Sequence
For multiframe sequences, additional fine tuning of the bandwidth of the entire sequence can be
achieved by configuring the last delay in the sequence, also known as the “trailing delay”, to only be
applied for every Nth injection of the sequence. This is achieved using the
TRAILING_DELAY_SEQ_CNT parameter and is shown in the following illustration.
Figure 65 • Fine Tuning Bandwidth of Multiframe DTI Sequence
Inserted after each
injection of Frame B.
DTI
TRAILING_DELAY_SEQ_CNT = 2
Inserted after every
second sequence injection.
Inserted after last injection of
Frame B.
Delay
DELAY=50
NEXT_PTR
Delay
DELAY=100
NEXT_PTR
Frame B
INJ_CNT=2
NEXT_PTR
Delay
DELAY=150
NEXT_PTR
Frame A
NEXT_PTR
FIRST_PTR
Delay
DELAY=1
NEXT_PTR=0
Resulting frame sequence:
Frame A
Frame B
150
3.23.3.4
100
Frame B
100 + 50 = 150
Frame A
Frame B
150
100
Frame B
100 + 50 = 150
...
Frame A
1
Time
Burst Size Test Using Single DTI
If a NEXT_PTR is set to point back to a previous entry in the sequence, then injection will continue
forever, that is, until the DTI is stopped. This is depicted in the following illustration. The configuration
shown can be used for leaky bucket burst size testing, where the first part of the sequence empties the
bucket, followed by a steady frame flow with the rate of the leaky bucket.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
236
Functional Descriptions
Figure 66 • DTI Frame/Delay Sequence Using Inject Forever
Inject forever
(In other words, until DTI is stopped)
DTI
Frame B
INJ_CNT=1
NEXT_PTR
Delay
DELAY=200
NEXT_PTR
Delay
DELAY=100
NEXT_PTR
Frame A
INJ_CNT=2
NEXT_PTR
FIRST_PTR
Delay
DELAY=150
NEXT_PTR
Resulting frame sequence:
Frame B
Frame B
100
100
3.23.3.5
150
200
...
Frame B
Frame B
150
Time
Burst Size Test Using DTI Concatenation
Two (or more) DTIs can be concatenated, such that when one DTI completes, another DTI is activated.
This is depicted in the following illustration. It can be used for leaky bucket burst size testing, where the
first part of the sequence empties the bucket, followed by a steady frame flow with the rate of the leaky
bucket.
Note that when DTI concatenation is used, the last delay entry in the frame-delay sequence of the first
DTI is not awaited before starting the next DTI. That is, the next DTI is started when the first DTI reads an
entry with NEXT_PTR = 0. As shown in the illustration, the delay between the last Frame A and the first
Frame B will not be 150 clock cycles, but instead approximately 12 clock cycles. If this is considered
problematic, it can be addressed by using an additional DTI with a sequence consisting only of two delay
entries. For example, DTI #2 could be inserted between DTI#1, and DTI#3 and DTI#2 could then be
configured with a sequence consisting of two delay entries, with the first having delay = 150.
Figure 67 • DTI Concatenation
DTI #1
MODE=2
CNT=3
DTI_NEXT=3
DTI #3
MODE=0
CNT=10
DTI #3 is enabled
when DTI #1
completes
Delay
DELAY=100
FIRST_PTR
Frame B
INJ_CNT=1
NEXT_PTR=0
NEXT_PTR
Frame A
INJ_CNT=1
NEXT_PTR
FIRST_PTR
Delay
DELAY=150
NEXT_PTR=0
Resulting frame sequence:
Frame B is injected 10 times
Frame A
Frame A
100
100
Frame A
...
Frame B
Frame B
150
150
Time
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
237
Functional Descriptions
3.23.3.6
DTI Bandwidth
For 64 bytes frames, AFI can inject up to 12 Gbps for a single DTI flow or inject a total bandwidth, across
all DTI flows, of up to 42 Gbps.
Higher injection bandwidths can be supported for frame sizes larger than 64 bytes.
Injections into ingress data path must be forwarded through VD1. For 64 bytes frames, the maximum
bandwidth through VD1 is 12 Gbps.
Note: Depending on port configuration, cell bus bandwidth may impose additional bandwidth limitation.
The bandwidth which a DTI is injecting into a queue must not exceed the bandwidth, which HSCH is
transmitting from the queue, because the port’s FRM_OUT_MAX will then be reached, thus possibly
affecting other DTIs injecting on the same port. For more information, see Port Parameters, page 245.
The only exception is if there is only one DTI injecting on the port, because there are no other DTIs that
could be affected.
3.23.3.7
DTI Sequence Processing Time
For high bandwidth DTI flows, the time it takes to process the delays and frames in a DTI sequence must
be taken into account:
•
•
•
Processing a frame entry with no succeeding delay entry takes 12 clock cycles.
Processing a frame entry with a succeeding delay entry takes 12 clock cycles.
Processing a delay entry, which does not succeed a frame entry takes 12 clock cycles.
For example, a sequence consisting of a frame entry followed by two delay entries will take 24 clock
cycles to process. If the frame is a 64-byte frame, and the clock period is 4 ns, this will correspond to a
maximum flow bandwidth of approximately 7 Gbps ((64 + 20) × 8 bits/(24 × 4 ns) = 7 Gbps), regardless
of the delay values configured for the two delays.
Although it takes 12 clock cycles to process a delay entry, it is valid to configure a delay entry with a
delay smaller than 12 clock cycles, because this will be compensated for when generating the delay
between later frames in the sequence. For more information, see Figure 65, page 236. For example, the
delay between the rightmost frame B and the succeeding frame A will be 150 + 12 clock cycles (instead
of 150 + 1). To compensate for this, however, the delay between the succeeding two frames A will be
150 – 11 clock cycles.
3.23.4
Timer Triggered Injection
For TTIs, frame injection is controlled by timers. To control the time between injections, configure the
following registers for each TTI:
•
•
TTI_TIMER.TICK_IDX. For each TTI, one of eight configurable timer ticks shown in the following
table must be chosen.
TTI_TIMER.TIMER_LEN. The number of timer ticks that must elapse between each injection.
That is, the period between each injection becomes tick_period × TIMER_LEN.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
238
Functional Descriptions
The following table lists the registers associated with TTI timer tickers.
Table 172 • TTI Timer Ticks Registers Overview
Register
Field
Description
Replication
TTI_TICK_LEN_0_3 LEN0 - LEN7 Length of timer ticks.
8
TTI_TICK_LEN_4_7
The length of each of the eight timer ticks is specified as multiples
of the length of the preceding timer tick (that is, -1).
Timer 0 is the shortest timer tick, and timer tick 7 is the longest.
Tick 0 is specified in multiple of TTI_TICK_BASE (default 52 µs).
Default configuration:
tick_idx tick_len
0
1
1
8
2
8
3
3
4
10
5
10
6
10
7
6
TTI_TICK_BASE
BASE_LEN
Tick_Period
52 µs
416 µs
3.3 ms
10 ms
100 ms
1 second
10 seconds
1 minute
(1 × 52 µs)
(8 × 52 µs)
(8 × 416 µs)
(3 × 3.3 ms)
(10 × 10 ms)
(10 × 100 ms)
(10 × 1 sec)
(6 × 10 sec)
Length of TTI base tick in system clock cycles.
1
The following table lists the registers associated with configuring parameters for each of the 4K entries in
the TTI table.
Table 173 • TTI Parameters (4096)
Register
Field
Description
Replication
TTI_PORT_QU PORT_NUM
Port number on which injection queue transmits.
Per TTI
TTI_PORT_QU SE_IDX
SE_INP
Injection queue. See Injection Queues, page 244.
Per TTI
TTI_TIMER
TICK_IDX
Which of the eight timer ticks is used by the timer controlling the
injection of this frame.
Per TTI
TTI_TIMER
JITTER_MODE Enables jitter for the number of timer ticks between each injection of Per TTI
this frame.
0: No jitter.
1: Timer is set to a random value in the range [TIMER_LEN*0.75;
TIMER_LEN].
2: Timer is set to a random value in the range [TIMER_LEN*0.50;
TIMER_LEN].
3: Timer is set to a random value in the range [1;TIMER_LEN].
TTI_TIMER
TIMER_LEN
Number of timer ticks between each injection of this frame.
Per TTI
0: Disables timer.
0xff: Injects frame next time the entry is serviced. After servicing,
hardware sets TIMER_LEN to 0. This is intended to be used during
removal of frame from buffer memory. See Removing Injection
Frames, page 245.
TTI_FRM
FRM_PTR
Points to the frame (in frame table), which the TTI injects.
TTI_TICKS
TICK_CNT
Number of ticks until next injection.
Per TTI
Should be set to a random value in the range 1-TIMER_LEN before
starting TTI.
TTI_MISC_CFG INJ_CNT_ENA Enables counting of injected frames in
TTI_MISC:TTI_INJ_CNT.TTI_INJ_CNT.
Per TTI
Per TTI
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
239
Functional Descriptions
An entry in the TTI table is checked approximately every two clock cycles. If the TTI’s tick (configured
through TICK_IDX) has changed, then the TICK_CNT is decremented. If it becomes zero, the frame is
injected, and TICK_CNT is set to TIMER_LEN.
3.23.4.1
TTI Calendar
In default configuration, TTI table entries are serviced from 0-4095, then restarted again at entry 0.
When configuring the TTI table, the following must be considered:
•
•
It takes up to 4 clock cycles, worst-case, to service an entry in the TTI table.
A TTI must be serviced more frequently than the frequency of the TTI’s tick (see
TTI_TIMER.TICK_IDX).
This means that looping through the entire TTI table may take 4096 × 4 = 16384 clock cycles. With a
clock period of 4 ns, this corresponds to approximately 66 µs. In other words, no TTI must use a tick
faster than 66 us.
If TTIs faster than 66 µs are required, the TTI calendar can be used to have some entries in the TTI table
serviced more often than others, meaning the TTI table can be split into sections with TTIs using ticks of
different speeds.
The TTI calendar consists of four entries, as described in Table 6
Table 174 • TTI Calendar Registers Overview
Register
Field
Description
Replication
TTI_CAL_SLOT_PTRS SLOT_START_PTR
SLOT_END_PTR
Calendar slot’s frame table start and end pointer.
4
TTI_CAL_SLOT_CNT
SLOT_CNT
Number of TTIs to service in slot before moving to next 4
TTI calendar slot.
TTI_CTRL
TTI_CAL_LEN
Length of TTI calendar.
TTI_CTRL
TTI_INIT
When set, initializes calendar to start at calendar slot 0. 1
Cleared by AFI when done.
1
The following illustration shows a configuration for the TTI calendar. In this case, only TTI entry 0-1023
are being used.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
240
Functional Descriptions
Figure 68 • TTI Calendar Example
TTI Table
TTI_CAL_LEN=2
start=0
0-255
TTI
Calendar
end=255
cnt=2
start=256
cnt=1
start
256-1023
end=1023
end
cnt
start
end
cnt
Order of TTI Table entry checks:
0,1,256,2,3,257, .... 254,255,384,0,1,385,...
In the example, it takes (256/2) × (1 + 2) × 4 = 1536 clock cycles to service all TTIs in the blue section.
With a clock cycle of 4 ns, the TTIs in the blue section must not use ticks faster than 1536 × 4 = 6144 ns.
Similarly, the 768 TTIs in the red section must not use ticks faster than
(768/1) × (1 + 2) × 4 × 4 ns = ~36.9 µs
3.23.4.2
Other TTI Parameters
Other TTI-related parameters are listed in the following table.
Table 175 • Miscellaneous TTI Registers Overview
Register
Field
Description
Replication
TTI_CTRL
TTI_ENA
Enables TTI.
1
Before enabling TTI, TTI_INIT should be used to initialize calendar state.
TTI_INJ_CNT TTI_INJ_CNT Number of TTI injections.
Enabled per TTI using TTI_TBL:TTI_MISC_CFG.INJ_CNT_ENA.
3.23.4.3
1
TTI Table Update Engine (AFI TUPE)
The AFI Table Update Engine (AFI TUPE) can be used to quickly update a large number of entries in the
TTI Table such as disabling or enabling timers in fail-over scenarios. AFI TUPE related parameters are
listed in the following table. The parameters prefixed with CRIT are used to specify the criteria, which
TTIs fulfill in order for TUPE to apply.
Table 176 • AFI TUPE Registers Overview
AFI:TUPE
Register
Field
Description
Replication
TUPE_MISC
TUPE_START
Start TUPE.
1
TUPE_MISC
CRIT_TUPE_CTRL_VAL_ENA
Enable use of CRIT_TUPE_CTRL_VAL and
CRIT_TUPE_CTRL_MASK.
1
TUPE_MISC
CRIT_PORT_NUM_ENA
Enable use of CRIT_PORT_NUM_VAL.
1
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
241
Functional Descriptions
Table 176 • AFI TUPE Registers Overview (continued)
AFI:TUPE
Register
Field
Description
Replication
TUPE_MISC
CRIT_QU_NUM_ENA
Enable use of CRIT_QU_NUM_VAL.
1
TUPE_MISC
CMD_TIMER_ENA_ENA
Enable use of CMD_TIMER_ENA_VAL.
1
TUPE_MISC
CMD_TIMER_ENA_VAL
TUPE command parameter: New TIMER_ENA value. 1
TUPE_MISC
CMD_PORT_NUM_ENA
Enable use of CMD_PORT_NUM_VAL.
1
TUPE_MISC
CMD_QU_NUM_ENA
Enable use of CMD_QU_NUM_VAL.
1
TUPE_ADDR TUPE_START_ADDR
First address in TTI table for AFI TUPE to process.
1
TUPE_ADDR TUPE_END_ADDR
Last address in TTI table for AFI TUPE to process.
1
TUPE_CRIT1 CRIT_PORT_NUM_VAL
TUPE criteria parameter controlling which TTI table
entries to update.
1
TUPE_CRIT1 CRIT_QU_NUM_VAL
TUPE criteria parameter controlling which TTI table
entries to update.
1
TUPE_CRIT2 CRIT_TUPE_CTRL_MASK
TUPE criteria parameter controlling which TTI table
entries to update.
1
TUPE_CRIT3 CRIT_TUPE_CTRL_VAL
TUPE criteria parameter controlling which TTI table
entries to update.
2
TUPE_CMD1 CMD_PORT_NUM_VAL
TUPE command parameter: New PORT_NUM value. 1
TUPE_CMD1 CMD_QU_NUM _VAL
TUPE command parameter: New QU_NUM value.
1
The following TTI parameters can be used as part of the TUPE criteria:
•
•
•
PORT_NUM
QU_NUM
TUPE_CTRL
The parameters prefixed "CMD" specify the commands, which are applied to any TTIs, which fulfill the
TUPE criteria. Using the TUPE command parameters, the following TTI parameters can be changed:
•
•
•
TIMER_ENA
Timers can be enabled/disabled.
PORT_NUM
Injections can be moved to a different port.
QU_NUM
Injections can be moved to a different queue.
While TUPE is running no injections will be performed for any TTIs which match the configured TUPE
criteria and fall within the configured TUPE address range.
The TUPE_CTRL field in the TTI Table can be used to classify TTIs into different groups, such that a
TUPE command can easily address all TTIs within such group.
The following illustration depics the AFI TUPE functionality.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
242
Functional Descriptions
Figure 69 • AFI TUPE
TTI Table (AFI:TTI_TBL)
TUPE_START_ADDR
TUPE_CTRL
Other TTI parameters
TUPE_END_ADDR
Possibly new value s for TTI
AFI TUPE
Criteria (CRIT)
and
Command (CMD)
Parameters
AFI TUPE Algorithm
The full algorithm used by AFI TUPE is shown in the following pseudo code. Configuration parameters
are prefixed “csr.”
// AFI Table UPdate Engine (AFI TUPE) Algorithm
bool tupe_ctrl_match;
for (addr = csr.tupe_start_addr; addr < csr.tupe_end_addr; addr++) {
tti_tbl_entry = tti_tbl[addr];
tupe_ctrl_match = FALSE;
for (i = 0; i < 2; i++) {
if ((tti_tbl_entry.tupe_ctrl & csr.crit_tupe_ctrl_mask) ==
csr.crit_tupe_ctrl_val[i]) {
tupe_ctrl_match = TRUE;
}
}
if (
(// Check matching TUPE_CTRL value
tupe_ctrl_match)
&&
(// If enabled, check if TTI's PORT_NUM matches csr.crit_port_num_val
!csr.crit_port_num_ena
||
(tti_tbl_entry.port_num == csr.crit_port_num_val))
&&
(// If enabled, check if TTI's QU_NUM matches csr.crit_qu_num_val
!csr.crit_qu_num_ena
||
(tti_tbl_entry.qu_num == csr.crit_qu_num_val))
) {
// TTI fulfills criterias => Apply TUPE command to TTI
// timer_ena
if (csr.cmd_timer_ena_ena) {
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
243
Functional Descriptions
tti_tbl_entry.timer_ena = csr.cmd_timer_ena_val;
}
// port_num
if (csr.cmd_port_num_ena) {
tti_tbl_entry.port_num = csr.cmd_port_num_val;
}
// qu_num
if (csr.cmd_qu_num_ena) {
tti_tbl_entry.qu_num = csr.cmd_qu_num_val;
}
// Write back to TTI table
tti_tbl[addr] = tti_tbl_entry;
}
}
3.23.5
Injection Queues
DTI and TTI may inject into any egress queue in the queue system. In injection context, the queues can
be divided into the following categories:
•
•
•
Normal queues. These queues are processed by each level of SEs in HSCH. Frames injected into
such queues are thus subject to the M-DWRR and shaping algorithms of the SEs. Frames are
injected into the tail of the selected queue.
Port injection queue without shaping. These queues, one for each port, inject frames on the port with
higher priority than normal queues. The state of the DLB shaper is disregarded and is not updated
with the size of the transmitted frame.
Injected frames are injected into the tail of the queue, but due to the high priority, the queue will
normally be (almost) empty.
Port injection queue with shaping. These queues, one for each port, inject frames on the port with
higher priority than normal queues. The state of the port shaper is respected and is updated with the
size of the transmitted frame.
Injected frames are injected into the tail of the queue, but due to the high priority, the queue will
normally be (almost) empty.
The queue into which a TTI or DTI injects frames is controlled by the QU_NUM parameter. The actual
value to be used for this parameter depends on the HSCH configuration. For more information, see
Queue Mapping, page 219.
For injections into the ingress data path, frames must be looped through VD1 and QU_NUM must be
configured to select a VD1 queue.
3.23.6
Adding Injection Frame
To add a frame for injection by AFI, the CPU must follow this procedure.
1.
2.
3.
4.
5.
6.
7.
Set AFI::MISC_CTRL.AFI_ENA to 1 before using AFI.
Send the frame to AFI. AFI_INJ must be set in the IFH. For more information, see Frame Headers,
page 14.
Poll AFI::NEW_FRM_CTRL.VLD to await the frame being received by AFI.
When the frame has been received by AFI, then copy frame information from AFI::NEW_FRM_INFO
to an unused entry in the Frame table.
Clear AFI::NEW_FRM_CTRL.VLD.
TTI: Set up the TTI table to have the frame injected with the desired interval and to the desired
queue and port. For more information, see Timer Triggered Injection, page 238.
DTI: For injection of a sequence of frames, repeat steps 1 through 4.
Set up the DTI Table to inject the frames. For more information, see Table 170, page 234.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
244
Functional Descriptions
Configure other DTI parameters. For more information, see Table 171, page 234.
3.23.7
Starting Injection
TTI is enabled by using TTI_INIT to initialize and then setting TTI_ENA = 1.
Each TTI is started by setting TIMER_LEN a non-zero value.
Each DTI is started by setting DTI_CTRL.ENA = 1.
3.23.8
Stopping Injection
Each TTI is stopped by setting TIMER_LEN to 0.
All TTIs can be stopped by setting TTI_ENA = 0.
Each DTI is stopped by setting DTI_CTRL.ENA = 0.
3.23.9
Removing Injection Frames
This section provides information about removing a single frame (TTI) or frame sequence (DTI) from the
buffer memory.
3.23.9.1
Single Frame (TTI)
To remove a single frame from buffer memory, the frame must be injected one more time. This “removal
injection” does not result in a frame transmission, but purely serves to remove the frame from the buffer
memory.
Use the following procedure to remove a single frame from buffer memory.
1.
2.
3.
Set the FRM_RM bit for frame in the frame table.
For TTI: Set TIMER_LEN to 0x1ff.
Poll the FRM_GONE bit until it gets set by AFI.
When performing removal injection, injection must be enabled for the corresponding port by setting
AFI:PORT_TBL[]:PORT_CFG.FRM_OUT_MAX != 0.
3.23.9.2
Frame Sequence (DTI)
Use the following procedure to remove a DTI frame sequence from buffer memory.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Disable the DTI by setting DTI_CTRL.ENA = 0.
Set the FRM_RM bit for each frame to be removed in the frame table.
Set DTI_FRM.NEXT_FRM_PTR to DTI_FRM.FIRST_FRM_PTR.
Set DTI_MODE.MODE = 0.
Set DTI_CNT.CNT = 1.
Set DTI_MODE.FRM_INJ_CNT to 0.
Optionally, set all delays in sequence to 0 to speed up the removal procedure.
Set DTI_CNT_DOWN.CNT_DOWN to 0.
Set DTI_CTRL.ENA to 1 to enable the DTI.
Poll the FRM_GONE for the last frame to be removed until the bit gets set by AFI.
This procedure causes the frames to be injected one last time and through this, be removed from buffer
memory. The frames will not actually be transmitted on the destination port.
When performing removal injection, injection must be enabled for the corresponding port by setting
AFI:PORT_TBL[]:PORT_CFG.FRM_OUT_MAX != 0.
3.23.10 Port Parameters
To ensure that the queue system does not overflow with injected frames, for example, if a port is in flow
control, an upper bound on the number of injected, but not yet transmitted, frames per port can be
configured in FRM_OUT_MAX.
If FRM_OUT_MAX is reached, then any DTI injections are postponed until the number of outstanding
frames falls below FRM_OUT_MAX. TTI injections uses a slightly higher limit of
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
245
Functional Descriptions
FRM_OUT_MAX+TTI_FRM_OUT_MAX. This ensures that TTI injection are still possible, even if a DTI
flow faster than the port speed has been configured.
If PFC is used in conjunction with automatic frame injection, then either all frames must be injected into
queues controlled by the same flow control priority, or all frames must be injected into queues that cannot
be stopped by PFC.
If EEE is used in conjunction with automatic frame injection, then all frames for that port must be injected
into queues with the same urgent configuration.
Setting FRM_OUT_MAX = 0 will stop all injections on port.
Table 177 • Port Parameters
Register
Field
Description
Replication
PORT_CFG
FRM_OUT_MAX
Maximum number of injections outstanding for the
port at-a-time.
Per port
PORT_CFG
FRM_RM_ONLY
Only allows frame removal injections. That is,
normal injections are not allowed.
Per port
TTI_PORT_FRM_OUT
TTI_FRM_OUT_MAX
Additional injections that can be outstanding before Per port
affecting TTI injection.
3.24
Rewriter
The switch core includes a rewriter (REW) that is common for all ports. The rewriter performs all frame
editing prior to frame transmission. Each frame can be handled multiple times by the rewriter
•
•
•
•
One time per destination port.
One time towards the mirror target port.
One time when copied or redirected to internal and/or external CPU.
One time when looped back to the analyzer.
All frames that are input to the rewriter can be modified by previous blocks of the frame processing flow.
The internal frame header informs the rewriter what ingress frame manipulations (popping) are
performed on any given frame. The same ingress frame manipulation is performed for each copy of a
frame, while the rewriter may perform per destination specific egress frame manipulations (pushing) to
the frame.
The rewriter is the final step in the frame processing flow of the device.
3.24.1
Rewriter Operation
The rewriter supports the following frame operations.
•
•
•
•
•
•
•
•
•
•
3.24.2
VLAN tag (802.1Q, 802.1ad) editing: tagging of frames and remapping of PCP and DEI.
L3 routing. SMAC/DMAC, VID and TTL modifications for IPv4 and IPv6.
Implement Precision Time Protocol (PTP) time stamping by interfacing to the PTP block.
Interfacing to the loopback block. Loopback frames to ANA based on VCAP_ES0 actions. Rewriting
MACs and IFH of looped frames.
DSCP remarking: rewriting the DSCP value in IPv4 and IPv6 frames based on classified DSCP
value.
Insert or update VSTAX headers.
Handling of both Rx and Tx mirror frames.
Padding of undersize frames to 64 bytes or 76 bytes.
Frame FCS update control.
Add preamble to all frames with an external port destination.
Supported Ports
The devices operate with up to 53 physical ports, two loopback ports, and two DEVCPU extraction ports
as possible frame destinations. These frame destinations are addressed by the rewriter using the egress
port number.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
246
Functional Descriptions
3.24.3
Supported Frame Formats
The rewriter can identify and rewrite both headers and payload of the following frame types.
Ethernet Frames
•
•
•
Ethernet link layer DMAC+SMAC
Maximum of three VLAN Q-tags (802.1Q, 802.1ad)
Payload (IPv4, IPv6, Y.1731 OAM, PTP, and so on)
The analyzer places information in the IFH to help the rewriter with frame identification. The IFH fields
IFH.DST.ENCAP.W16_POP_CNT and IFH.DST.ENCAP.TYPE_AFTER_POP are used for this purpose.
3.24.3.1
Maximum Frame Expansion
The rewriter can push 60 bytes into a frame when the IFH is popped and when no other frame pop
operations are done. The frame preamble will occupy 8 of the 60 bytes that can be pushed.
3.24.4
Rewriter Initialization
Rewriter initialization comprises two steps:
•
•
Set REW::RAM_INIT.RAM_ENA to 1
Set REW::RAM_INIT.RAM_INIT to 1
Before the rewriter can be configured, the RAM-based configuration registers must be initialized by
writing a 1 to the above RAM_INIT registers. The RAM_INIT.RAM_INIT register is reset by hardware
when the initialization is complete.
If VCAP_ES0 is enabled, it must be initialized. All of the default port actions in VCAP_ES0 should also be
initialized to ensure proper operation. For more information about initializing VCAP_ES0, see Versatile
Content-Aware Processor (VCAP™), page 56.
3.24.5
VCAP_ES0 Lookup
The rewriter performs stage 0 VCAP egress matching (VCAP_ES0) lookups for each frame when
enabled. The following table lists the registers associated with VCAP_ES0 lookup.
Table 178 • ES0 Configuration Registers
Register
Description
Replication
ES0_CTRL.
ES0_LU_ENA
Enables lookup in VCAP_ES0 to control advanced frame
modifications.
None
ES0_CTRL.
ES0_BY_RLEG
Enables ES0 router mode lookup when IFH.FWD.DST_MODE
indicates routing.
None
ES0_CTRL.
ES0_BY_RT_FWD
Enables ES0 router mode lookup when IFH.DST.ENCAP.RT_FWD None
indicates routing.
PORT_CTRL.
ES0_LPORT_NUM
Maps the configuration port to a logical port number to be used by Ports
ES0 keys. The port used in the lookup can be Tx-mirrored.
VCAP_ES0 lookup is enabled by setting REW::ES0_CTRL.ES0_LU_ENA = 1. Frames destined to the
DEVCPU cannot be rewritten, and there is no VCAP_ES0 lookup for these frames.
All ES0 actions are ignored when VCAP_ES0 is disabled.
There are two ES0 key types: VID and ISDX.
The VID key is always used if:
•
•
•
IFH.FWD.ES0_ISDX_KEY_ENA = 0
REW::ES0_CTRL.ES0_BY_RLEG = 1 and (IFH.FWD.DST_MODE = L3UC_ROUTING or
IFH.FWD.DST_MODE = L3MC_ROUTING)
REW::ES0_CTRL.ES0_BY_RT_FWD = 1 and IFH.DST.ENCAP.RT_FWD = 1.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
247
Functional Descriptions
The ISDX key is used if a VID key is not used and IFH.FWD.ES0_ISDX_KEY_ENA = 1.
Table 179 • VCAP_ES0 Keys
Key Field
Description
Size
ISDX
VID
X1_TYPE
X1 type.
0: ISDX.
1: VID.
1
x
x
EGR_PORT
Logical egress port number.
6
Configuration port mapped via REW::PORT_CTRL.ES0_LPORT_NUM. The
default is no mapping (EGR_PORT = configuration port number).
The configuration port is either the physical port or a Tx-mirror port number.
x
x
PROT_ACTIVE Protection is active. Value is IFH.ENCAP.PROT_ACTIVE.
1
x
x
VSI
10
x
x
Virtual Switch Instance.
Default value is VSI = IFH.DST.ENCAP.GEN_IDX if
IFH.DST.ENCAP.GEN_IDX_MODE = 1 else 0.
The following conditions will change the default:
If REW::ES0_CTRL.ES0_BY_RLEG = 1 and
(IFH.FWD.DST_MODE = L3UC_ROUTING or
IFH.FWD.DST_MODE = L3MC_ROUTING)
Force VSI = 0x3ff to identify routing.
If REW::ES0_CTRL.ES0_BY_RT_FWD = 1 and IFH.ENCAP.RT_FWD = 1.
Force VSI = 0x3ff to identify routing.
COSID
Class of Service Identifier.
Value is IFH.VSTAX.MISC.COSID if
REW::PORT_CTRL.VSTAX2_MISC_ISDX_ENA = 1 else 0.
3
x
X
COLOR
Frame color.
Value is IFH.VSTAX.QOS.DP mapped through REW::DP_MAP.DP.
1
x
x
SERVICE_FRM Service frame.
Set to 1 if IFH.VSTAX.MISC.ISDX > 0 and
REW::PORT_CTRL.VSTAX2_MISC_ISDX_ENA = 1 else 0.
1
x
x
ISDX
Ingress Service Index.
Value is IFH.VSTAX.MISC.ISDX if
REW::PORT_CTRL.VSTAX2_MISC_ISDX_ENA = 1 else 0.
12
x
VID
IEEE VLAN identifier.
Default value is VID = IFH.VSTAX.TAG.VID.
The following conditions will change the default:
If REW::ES0_CTRL.ES0_BY_RLEG = 1 and (IFH.FWD.DST_MODE =
L3UC_ROUTING or IFH.FWD.DST_MODE = L3MC_ROUTING)
VID = IFH.DST.L3[UC|MC].ERLEG
12
x
If REW::ES0_CTRL.ES0_BY_RT_FWD = 1 and
IFH.DST.ENCAP.RT_FWD = 1
VID = IFH.DST.ENCAP.GEN_IDX.
The following table shows the actions available in VCAP_ES0. Default actions are selected by
PORT_CTRL.ES0_LPORT_NUM when no ES0 entry is hit.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
248
Functional Descriptions
When REW::ES0_CTRL.ES0_LU_ENA = 1, all of the default actions must be initialized to ensure correct
frame handling.
Table 180 • VCAP_ES0 Actions
Field Name
Description
Width
PUSH_OUTER_TAG Controls tag A (outer tagging).
0: Port tagging. Push port tag as outer tag if enabled for port. No ES0 tag A.
1: ES0 tag A. Push ES0 tag A as outer tag. No port tag.
2: Forced port tagging. Push port tag as outer tag. No ES0 tag A.
3: Forced untagging. No outer tag pushed (no port tag, no ES0 tag A).
2
PUSH_INNER_TAG
Controls tag B (inner tagging).
0: Do not push ES0 tag B as inner tag.
1: Push ES0 tag B as inner tag.
1
TAG_A_TPID_SEL
Selects TPID for ES0 tag A.
0: 0x8100.
1: 0x88A8.
2: Custom1.
3: Custom2.
4: Custom3.
5: Classified. Selected by ANA in IFH.VSTAX.TAG_TYPE and
IFH.DST.ENCAP.TAG_TPID:
If IFH.DST.ENCAP.TAG_TPID = STD_TPID:
If IFH.VSTAX.TAG.TAG_TYPE = 0, then 0x8100 else 0x88A8
If IFH.DST.ENCAP.TAG_TPID = CUSTOM[n]:
REW::TPID_CFG[n]:TPID_VAL.
3
TAG_A_VID_SEL
Selects VID for ES0 tag A.
0: Classified VID + VID_A_VAL.
1: VID_A_VAL.
1
TAG_A_PCP_SEL
Select PCP source for ES0 tag A.
0: Classified PCP.
1: PCP_A_VAL.
2: Reserved.
3: PCP of popped VLAN tag if available (IFH.VSTAX.TAG.WAS_TAGGED = 1 and
num_popped_tags>0) else PCP_A_VAL.
4: Mapped using mapping table 0, otherwise use PCP_A_VAL.
5: Mapped using mapping table 1, otherwise use mapping table 0.
6: Mapped using mapping table 2, otherwise use PCP_A_VAL.
7: Mapped using mapping table 3, otherwise use mapping table 2.
3
TAG_A_DEI_SEL
Select DEI source for ES0 tag A.
0: Classified DEI.
1: DEI_A_VAL.
2: REW::DP_MAP.DP [IFH.VSTAX.QOS.DP].
3: DEI of popped VLAN tag if available (IFH.VSTAX.TAG.WAS_TAGGED = 1 and
num_popped_tags>0) else DEI_A_VAL.
4: Mapped using mapping table 0, otherwise use DEI_A_VAL.
5: Mapped using mapping table 1, otherwise use mapping table 0.
6: Mapped using mapping table 2, otherwise use DEI_A_VAL.
7: Mapped using mapping table 3, otherwise use mapping table 2.
3
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
249
Functional Descriptions
Table 180 • VCAP_ES0 Actions (continued)
Field Name
Description
Width
TAG_B_TPID_SEL
Selects TPID for ES0 tag B.
0: 0x8100.
1:0x88A8.
2: Custom 1.
3: Custom 2.
4: Custom 3.
5: See TAG_A_TPID_SEL.
3
TAG_B_VID_SEL
Selects VID for ES0 tag B.
0: Classified VID + VID_B_VAL.
1: VID_B_VAL.
1
TAG_B_PCP_SEL
Selects PCP source for ES0 tag B.
0: Classified PCP.
1: PCP_B_VAL.
2: Reserved.
3: PCP of popped VLAN tag if available (IFH.VSTAX.TAG.WAS_TAGGED=1 and
num_popped_tags>0) else PCP_B_VAL.
4: Mapped using mapping table 0, otherwise use PCP_B_VAL.
5: Mapped using mapping table 1, otherwise use mapping table 0.
6: Mapped using mapping table 2, otherwise use PCP_B_VAL.
7: Mapped using mapping table 3, otherwise use mapping table 2.
3
TAG_B_DEI_SEL
Selects DEI source for ES0 tag B.
0: Classified DEI.
1: DEI_B_VAL.
2: REW::DP_MAP.DP [IFH.VSTAX.QOS.DP].
3: DEI of popped VLAN tag if available (IFH.VSTAX.TAG.WAS_TAGGED = 1 and
num_popped_tags>0) else DEI_B_VAL.
4: Mapped using mapping table 0, otherwise use DEI_B_VAL.
5: Mapped using mapping table 1, otherwise use mapping table 0.
6: Mapped using mapping table 2, otherwise use DEI_B_VAL.
7: Mapped using mapping table 3, otherwise use mapping table 2.
3
TAG_C_TPID_SEL
Selects TPID for ES0 tag C.
0: 0x8100.
1:0x88A8.
2: Custom 1.
3: Custom 2.
4: Custom 3.
5: See TAG_A_TPID_SEL.
3
TAG_C_PCP_SEL
Selects PCP source for ES0 tag C.
0: Classified PCP.
1: PCP_C_VAL.
2: Reserved.
3: PCP of popped VLAN tag if available (IFH.VSTAX.TAG.WAS_TAGGED=1 and
num_popped_tags>0) else PCP_C_VAL.
4: Mapped using mapping table 0, otherwise use PCP_C_VAL.
5: Mapped using mapping table 1, otherwise use mapping table 0.
6: Mapped using mapping table 2, otherwise use PCP_C_VAL.
7: Mapped using mapping table 3, otherwise use mapping table 2.
3
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
250
Functional Descriptions
Table 180 • VCAP_ES0 Actions (continued)
Field Name
Description
Width
TAG_C_DEI_SEL
Selects DEI source for ES0 tag C.
0: Classified DEI.
1: DEI_C_VAL.
2: REW::DP_MAP.DP [IFH.VSTAX.QOS.DP].
3: DEI of popped VLAN tag if available (IFH.VSTAX.TAG.WAS_TAGGED = 1 and
num_popped_tags>0) else DEI_C_VAL.
4: Mapped using mapping table 0, otherwise use DEI_C_VAL.
5: Mapped using mapping table 1, otherwise use mapping table 0.
6: Mapped using mapping table 2, otherwise use DEI_C_VAL.
7: Mapped using mapping table 3, otherwise use mapping table 2.
3
VID_A_VAL
VID used in ES0 tag A. See TAG_A_VID_SEL.
12
PCP_A_VAL
PCP used in ES0 tag A. See TAG_A_PCP_SEL.
3
DEI_A_VAL
DEI used in ES0 tag A. See TAG_A_DEI_SEL.
1
VID_B_VAL
VID used in ES0 tag B. See TAG_B_VID_SEL.
12
PCP_B_VAL
PCP used in ES0 tag B. See TAG_B_PCP_SEL.
3
DEI_B_VAL
DEI used in ES0 tag B. See TAG_B_DEI_SEL.
1
VID_C_VAL
VID used in ES0 tag C. See TAG_C_VID_SEL.
12
PCP_C_VAL
PCP used in ES0 tag C. See TAG_C_PCP_SEL.
3
DEI_C_VAL
DEI used in ES0 tag C. See TAG_C_DEI_SEL.
1
POP_VAL
Pops one additional Q-tag.
num_popped_tags = IFH.tagging.pop_cnt + POP_VAL.
The rewriter counts the number of Q-tags in the frame and only pops tags that are
present in the frame. NUM_POPPED_TAGS is equal to the last available tag.
1
UNTAG_VID_ENA
Controls insertion of tag C. Un-tag or insert mode can be selected. See
PUSH_CUSTOMER_TAG.
1
PUSH_CUSTOMER_ Selects tag C mode:
TAG
0: Do not push tag C.
1: Push tag C if IFH.VSTAX.TAG.WAS_TAGGED = 1.
2: Push tag C if IFH.VSTAX.TAG.WAS_TAGGED = 0.
3: Push tag C if UNTAG_VID_ENA = 0 or (C-TAG.VID ! = VID_C_VAL).
2
TAG_C_VID_SEL
Selects VID for ES0 tag C. The resulting VID is termed C-TAG.VID.
0: Classified VID.
1: VID_C_VAL.
1
DSCP_SEL
Selects source for DSCP.
0: Controlled by port configuration and IFH.
1: Classified DSCP via IFH.
2: DSCP_VAL.
3: Reserved.
4: Mapped using mapping table 0, otherwise use DSCP_VAL.
5: Mapped using mapping table 1, otherwise use mapping table 0.
6: Mapped using mapping table 2, otherwise use DSCP_VAL.
7: Mapped using mapping table 3, otherwise use mapping table 2.
3
DSCP_VAL
DSCP value.
6
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
251
Functional Descriptions
Table 180 • VCAP_ES0 Actions (continued)
Field Name
Description
Width
PROTECTION_SEL
Change ENCAP_ID, ESDX_BASE and OAM_MEP_IDX based on
IFH.DST.ENCAP.PROT_ACTIVE.
0: No protection. Do not use protection index values.
1: Use _P if ifh.encap.prot_active = 1.
2: Use _P if ifh.encap.prot_active = 0.
3: Reserved.
2
RESERVED
Must be set to 0.
41
ENCAP_ID
Index into the MPLS encapsulation table (REW::ENCAP). Setting ENCAP_ID to zero 10
disables pushing of MPLS encapsulation.
0: Disables the use of MPLS encapsulation.
1-1023: Selects ENCAP ID.
ENCAP_ID_P
Index to use when enabled by PROTECTION_SEL. The encoding is equal to
ENCAP_ID.
POP_CNT
If POP_CNT > 0, then ifh.dst.encap.w16_pop_cnt is overruled with POP_CNT when 5
popping MPLS labels. The encoding is:
0: Use ifh.dst.encap.w16_pop_cnt as word16 (2 bytes) pop count
1: Do not pop any bytes.
2: Pop 2 × 2 = 4 bytes.
…
21: Pop 2 × 21 = 42 bytes.
22-31: Reserved.
If the number of bytes popped by POP_CNT is larger than the value given by
ifh.dst.encap.w16_pop_cnt, the IFH value is always used.
ESDX_BASE
Egress service index. Used to index egress service counter set
(REW::CNT_CTRL.STAT_MODE).
13
ESDX_BASE _P
Egress service index to use when enabled by PROTECTION_SEL.
13
ESDX_COSID_
OFFSET
Egress counter set, offset per COSID.
24
Stat index = ESDX_BASE + ESDX_COSID_OFFSET[(3 x COSID + 2) : 3 x COSID]
MAP_0_IDX
Index 0 into mapping resource A.
Index bits 11:3. Index bits 2:0 are controller by MAP_0_KEY.
9
MAP_1_IDX
Index 1 into mapping resource A.
Index bits 11:3. Index bits 2:0 are controller by MAP_1_KEY.
9
MAP_2_IDX
Index 0 into mapping resource B.
Index bits 11:3. Index bits 2:0 are controller by MAP_2_KEY.
9
MAP_3_IDX
Index 1 into mapping resource B.
Index bits 11:3. Index bits 2:0 are controller by MAP_2_KEY.
9
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
10
252
Functional Descriptions
Table 180 • VCAP_ES0 Actions (continued)
Field Name
Description
MAP_0_KEY
Key used when looking up mapping table 0.
4
QoS mappings:
0: QoS (8 entries): IDX = IDX_A + QOS.
1: DP, QoS (32 entries): IDX = IDX_A + IFH..DP × 8 + QOS.
DSCP mappings:
2: DSCP (64 entries): IDX = IDX_A + IFH..DSCP.
3: DP, DSCP (256 entries): IDX = IDX_A + 64 × IFH..DP + IFH..DSCP.
4: DP, TOS_PRE (32 entries): IDX = IDX_A + IFH..DP × 8 + TOS_PRE.
PCP mappings:
5: PCP (8 entries): IDX = IDX_A + IFH..PCP.
6: DP, PCP (32 entries): IDX = IDX_A + IFH..DP × 8 + IFH..PCP.
7: DEI, PCP (16 entries): IDX = IDX_A + IFH..DEI × 8 + IFH..PCP.
TC mappings:
8: TC: IDX = IDX_A + IFH..TC.
9: DP, TC: IDX = IDX_A + IFH..DP × 8 + IFH..TC.
Popped customer tag mappings:
10: Popped PCP (8 entries): IDX = MAP_0_IDX + pop.PCP
11: DP, popped PCP (32 entries): IDX = MAP_0_IDX + IFH..DP × 8 + pop.PCP.
12: Popped DEI, popped PCP (16 entries): IDX = MAP_0_IDX + pop.DEI × 8 +
pop.PCP.
COSID mappings:
13: COSID (8 entries): IDX = IDX_A + IFH.VSTAX.MISC.COSID.
14: DP, COSID (32 entries): IDX = IDX_A + IFH..DP × 8 + IFH.VSTAX.MISC.COSID.
MAP_1_KEY
See MAP_0_KEY.
4
MAP_2_KEY
See MAP_0_KEY.
4
MAP_3_KEY
See MAP_0_KEY.
4
RESERVED
Must be set to 0.
34
FWD_SEL
ES0 Forward selector.
0: No action.
1: Copy to loopback interface.
2: Redirect to loopback interface.
3: Discard.
2
CPU_QU
CPU extraction queue. Used when FWD_SEL >0 and PIPELINE_ACT = XTR.
3
PIPELINE_PT
ES0 pipeline point.
0: REW_IN_SW.
1: REW_OU_SW.
2: REW_SAT.
3: Reserved.
2
PIPELINE_ACT
Pipeline action when FWD_SEL >0.
0: XTR. CPU_QU selects CPU extraction queue
1: LBK_ASM.
1
SWAP_MAC_ENA
This setting is only active when FWD_SEL = 1 or FWD_SEL = 2 and
PIPELINE_ACT = LBK_ASM.
0: No action.
1: Swap MACs and clear bit 40 in new SMAC.
1
LOOP_ENA
0: Forward based on PIPELINE_PT and FWD_SEL
1
1: Force FWD_SEL=REDIR, PIPELINE_ACT = LBK_ASM,
PIPELINE_PT = REW_SAT, swap MACs and clear bit 40 in new SMAC. Do not apply
CPU_QU.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
Width
253
Functional Descriptions
3.24.5.1
Rewriter Pipeline Handling
In order to achieve the correct statistics and processing of frames, it is important that frames can be
extracted, injected, discarded, and looped at specific positions in the processing flow. Based on the
position, processing—especially counters, are affected.
Note that a frame is always physically passed through the whole processing. Logically, certain elements
of the processing can be disabled or enabled.
The following table lists the pipeline points available in the rewriter.
Table 181 • Rewriter Pipeline Point Definitions
Pipeline Point
What can set it?
Position in Flow
NONE
Default
0
REW_IN_MIP
Inner MIP configured in rewriter
1
REW_IN_SW
Inner software MEP controlled by VCAP_ES0
2
REW_IN_VOE
Service VOE in VOP
3
REW_OU_VOE
Service VOE in VOP
4
REW_OU_SW
Outer software MEP controlled by VCAP_ES0
5
REW_OU_MIP
Outer software MIP configured in rewriter
6
REW_SAT
SAT software MEP controlled by VCAP_ES0
7
REW_PORT_VOE
Port VOE in VOP
8
REW_VRAP
Set in VRAP reply frame
9
Each point in the flow assigns one of the possible pipeline actions listed in the following table.
Table 182 • Pipeline Actions
Action Type
Name
Comment
Inject
INJ
INJ_MASQ
INJ_CENTRAL
Injection actions set by ANA are cleared when the frame enters the rewriter by
setting the pipeline point and action to NONE.
Extract
XTR
XTR_UPMEP
XTR is set by ES0 and MIP.
XTR_UPMEP is also set by the VOP.
Loopback
LBK_ASM
LBK_QS
LBK_QS is set in ANA. This action is treated as an injection action in the
rewriter. LBK_ASM can be set by ES0 when looping frames back to ANA. This
action is treated as an extraction in the rewriter.
None
NONE
Default. No pipeline point and action is assigned to frame.
Frames looped by the analyzer (PIPELINE_ACT = LBK_QS) have their ANA pipeline point changed to a
REW pipeline point, which indicates the point in the rewriter flow in REW where they appear again after
being looped. The following pipeline point translations are handled.
•
•
•
PIPELINE_PT = ANA_PORT_VOE is changed to REW_PORT_VOE
PIPELINE_PT = ANA_OU_VOE is changed to REW_OU_VOE
PIPELINE_PT = ANA_IN_VOE is changed to REW_IN_VOE
Frame forward and counter updates are done based on the assigned pipeline points and actions. In the
rewriter, pipeline points and actions can be assigned by ES0, the MIP, and the VOP.
Frames injected by a CPU can also have pipeline point and actions set in the injection IFH.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
254
Functional Descriptions
The rules listed in the following table apply when pipeline points are updated.
Table 183 • Pipeline Point Updating Rules
Pipeline Action
Rule
None
The pipeline point and actions can be updated.
Inject
If a frame is injected in pipeline point N, the forwarding cannot be changed in pipeline point N-1
and it will not be counted in the N-1 point. Logically the frame does not exist in the N-1 point.
Example: A frame is injected in the REW_VRAP pipeline point (Pipeline point = REW_VRAP,
Action = INJ). The SW-MEP is configured to loop the same frame in the pipeline point
REW_SAT. The frame will not be looped, because it was injected later in the pipeline
(REW_VRAP > REW_SAT). The frame will not be counted by the egress service statics, which
is located in the REW_PORT_VOE pipeline point for injected frames.
Extract
If a frame is extracted in pipeline point N the forwarding cannot be changed in pipeline point
N+1 and it will not be counted in the N+1 point. Logically the frame does not exist in the N+1
point.
Example: A frame is extracted in the REW_IN_MIP pipeline point (Pipeline point =
REW_IN_MIP, Action = XTR). The SW-MEP is configured to loop the same frame in the pipeline
point REW_SAT. The frame will not be looped because it has already been extracted earlier in
the pipeline (REW_IN_MIP < REW_SAT). The frame will not be counted by the egress service
statics, which is located in the REW_OU_SW pipeline point for extracted frames.
3.24.5.2
Frame Copy, Redirect, or Discard
Frame forwarding may be changed by ES0 action FWD_SEL, the MIP or the VOP. Changing frame
forwarding will update the frame pipeline point and action.
The following options are available to control frame forwarding.
•
•
•
•
No action. Do not change frame forwarding.
Copy frame to CPU via the loopback interface. The frame is looped back to the ANA where it is sent
to the CPU. The IFH of the CPU copy is modified to select a CPU queue. The frame is also
forwarded as normal to the destination port and can be modified by the normal rewriter operations.
Redirect frame to ANA via loopback interface. When doing frame loopbacks, the destination port of
the redirected frame will be left unchanged. The IFH of the frame is modified and the MAC
addresses may be swapped. Redirected frames may also be sent to a CPU queue. This can be
done as a standalone operation or together with the frame loopback. When redirecting, the frame is
only sent to the loopback interface and not to the original destination port.
Discard frame. The frame is terminated before transmission.
The following illustrations depicts options for frame forwarding.
Figure 70 • Frame Forward Options
To DSM
No action or copy
DA
SA
Changed
Payload
F
C
S
From OQS
IFH
DA
SA
Payload
F
C
S
To LBK
Copy or redirect
Rewriter
IFH(1) SA(2) DA(2)
Payload
F
C
S
1. The IFH is modified for looped frames.
2. MACs can be swapped for looped frames.
Terminate
Discard
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
255
Functional Descriptions
The following table lists the registers associated with the frame loopback options.
Table 184 • Frame Loopback Options
Register
Description
Replication
ES0_CTRL.
Using ES0 it is possible to loop frames back to ANA with the
ES0_FRM_LBK_CFG LOOP_ENA action.
If this bit is set, a frame can only be looped once by ES0.
None
Frame forwarding is changed if allowed by the current frame pipeline point and action. For more
information, see Rewriter Pipeline Handling, page 254.
The following table shows the pipeline action when the frame forwarding is changed.
Table 185 • Pipeline Action Updates
Forwarding Selection
Pipeline Action Updates
NONE
Unchanged
COPY
Unchanged
REDIR
CPU redirection: XTR / XTR_UPMEP
Loopback frames: LBK_ASM
DISCARD
XTR / XTR_UPMEP
The pipeline updating rules ensures that a REDIR or DISCARD decision cannot be changed at a later
pipeline point. A COPY may be changed at a later point to either a REDIR or DISCARD action.
•
•
If a copy is changed to a discard, the CPU still receives the frame copy.
If a copy is changed to a redirection, the CPU receives a copy and the frame is looped back or also
sent to the redirection queue.
When frames are copied or redirected the IFH is updated as described in the following table.
Table 186 • Loopback IFH Updates
IFH Field
Updated by
FWD.SRC_PORT
COPY or REDIR. The frame source port is changed to the current destination port.
MISC.PIPELINE_PT
COPY or REDIR. The pipeline point in which the frame forwarding was updated.
MISC.PIPELINE_ACT
COPY or REDIR. The pipeline action assigned to the frame.
MISC.CPU_MASK
Any operation. A CPU copy may be generated by all forward selections.
FWD.DO_LBK
Rewriter loopback (ES0.LOOP_ENA). Set this bit to indicate that the frame has been
looped. Can optionally be used to prevent multiple loops of the same frame.
FWD.UPDATE_FCS
VOP. Set by the VOP if a looped frames changed.
VSTAX.MISC.ISDX
VOP. The frame ISDX can be changed by the VOP.
VSTAX.QOS.DP
VOP. The DP level can be set to 0 by the VOP.
ENCAP.MPLS_TTL
VOP. The MPLS_TTL can be set to 1 by the VOP.
3.24.5.3
Egress Statistics Update
The rewriter does not have Egress Service Index (ESDX) and port-based counters of its own. Instead,
the egress statistic counters in the XQS:STAT are used for all frame and byte counting. For more
information, see Statistics, page 229.
The following counters are available to the rewriter as frame and octet counters.
•
Per egress port: 2 × 8 + 1 = 17 counters (color × cell bus priority + abort)
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
256
Functional Descriptions
•
ESDX: 2 × 8192 = 16384 counters (color × ESDX)
Frame and octets are counted simultaneously on each index by two separate counters. The counter
widths are 40 bits for octet counters and 32 bits for frame counters.
The following table lists the registers associated with ESDX counter configuration.
Table 187 • Egress Statistics Control Registers
Register
Description
Replication
CNT_CTRL.
STAT_MODE
Configures ESDX counter index selection.
Global
CNT_CTRL.
VSTAX_STAT_ESDX_DIS
Configures ESDX counting for stacking ports.
If this bit is set and PORT_CTRL.VSTAX_HDR_ENA = 1, all
counting based on the ESDX value is disabled regardless of the
CNT_CTRL.STAT_MODE configuration.
Global
CNT_CTRL.
Enables counting of frames discarded by the rewriter.
STAT_CNT_FRM_ABORT_ENA This bit only enables counting of frames discarded by ES0 or the
SW_MIP. Frame discards done by the VOP are not included.
Global
PORT_CTRL.
XTR_STAT_PIPELINE_PT
Configures the extraction statistics pipeline point. Frames extracted Port
before the configured pipeline point are not counted by the ESDX
counters.
Configuring the REW_IN_MIP value causes all extracted frames to
be counted.
Default is REW_OU_SW.
PORT_CTRL.
INJ_STAT_PIPELINE_PT
Configures the injection statistics pipeline point. Frames injected
Port
after the configured pipeline point are not counted by the ESDX
counters.
Configuring the REW_VRAP value causes all injected frames to be
counted.
Default is REW_OU_VOE.
3.24.5.4
Statistics Counter Index Calculation
The port counter index is always the physical port number and priority. The frame color is determined in
the same manner as the ESDX counter.
The ESDX counter index calculation is controlled by the CNT_CTRL.STAT_MODE register.
Table 188 • ESDX Index Selection
STAT_MODE
Description
0
Use ESDX if available:
ESDX is available if ES0 lookup is enabled and if ES0.ESDX_BASE is different from 0.
Index = ES0.ESDX_BASE + ES0.ESDX_COSID_OFFSET(IFH.VSTAX.MISC.COSID).
If ESDX is not available:
Index = IFH.VSTAX.MISC.ISDX (only 4096 available)
Regardless of the index selection, the frame color is:
Color = DP_MAP.DP(IFH.VSTAX.QOS.DP)
1
Similar to STAT_MODE = 0, except counting is disabled if the ESDX is not available.
2
Use ISDX: Index = IFH.VSTAX.MISC.ISDX.
The frame color is used to count multicast frames:
Color = FRAME.ETH_LINK_LAYER.DMAC (bit 40).
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
257
Functional Descriptions
Table 188 • ESDX Index Selection (continued)
STAT_MODE
Description
3
Use VID:
Index = Classified VID (IFH.VSTAX.TAG.VID), if no tag is pushed
Index = VID of outermost pushed tag, if a tag is pushed
Index = REW:VMID:RLEG_CTRL.RLEG_EVID (IFH.DST..ERLEG) if L3.
The frame color is used to count multicast frames:
Color = FRAME.ETH_LINK_LAYER.DMAC (bit 40).
Both port counters and ESDX counters are updated based on pipeline points and actions. For more
information, see Rewriter Pipeline Handling, page 254. The ESDX statistics pipeline points are fixed.
The following table shows when the counters are updated.
Table 189 • Egress Statistics Update
Counter
Is Updated When?
Port
Pipeline action is not Extract (action different from XTR, XTR_UPMEP, and LBK_ASM).
Frame is transmitted (abort = 0).
Updated for all egress port numbers including virtual device (VD) and extraction CPU port numbers.
ESDX
The egress port is a physical port.
The frame matches the parameters configured in CNT_CTRL.STAT_MODE.
For extracted frames (Action: XTR, XTR_UPMEP and LBK_ASM):
The egress statics is located in the pipeline point, PORT_CTRL.XTR_STAT_PIPELINE_PT. Frames
extracted in or after this point are counted.
For injected frames (Action: INJ, INJ_x, LBK_QS):
The egress statics is located the pipeline point, PORT_CTRL.INJ_STAT_PIPELINE_PT. Frames
injected in or before this point are counted.
Frame is transmitted (abort = 0).
The pipeline action is different from XTR_LATE_REW.
Abort
A frame is aborted by REW or OQS (abort = 1).
Counting of frames aborted by REW must be enabled by setting
CNT_CTRL.STAT_CNT_FRM_ABORT_ENA.
3.24.5.5
Protection Active
Using ES0, the rewriter can change various indexes, based on the value of the
IFH.DST.ENCAP.PROT_ACTIVE field in the IFH.
•
•
•
3.24.6
Use the ES0 key field PROT_ACTIVE to change all ES0 actions when protection is active.
The numbers of ES0 keys are limited, so the same key can optionally generate two different indexes
based on the value of IFH.DST.ENCAP.PROT_ACTIVE. This is enabled using the ES0 action
PROTECTION_SEL.
The ENCAP_ID, ESDX_BASE, and OAM_MEP_IDX indexes can be changed. These indexes are
used when enabled by PROTECTION_SEL: ENCAP_ID_P, ESDX_BASE_P, and
OAM_MEP_IDX_P.
Mapping Tables
The rewriter contains two mapping resources (A and B) that can be used to look up the following fields.
•
•
•
•
TC value in MPLS labels
DSCP value in IP frames
DEI in 802.3 VLAN tags
PCP in 802.3 VLAN tags
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
258
Functional Descriptions
The following table lists the configuration registers associated with the mapping tables.
Table 190 • Mapping Table Configuration Registers
Register
Description
Replication
MAP_VAL_x:TC_VAL
Mapped TC value
4096 × 2
MAP_VAL_x:DSCP_VAL
Mapped DSCP value
4096 × 2
MAP_VAL_x:DEI_VAL
Mapped DEI value
4096 × 2
MAP_VAL_x:PCP_VAL
Mapped PCP value
4096 × 2
MAP_VAL_x:OAM_COLOR
Mapped OAM Color
4096 × 2
MAP_VAL_x:OAM_COSID
Mapped OAM Cosid
4096 × 2
MAP_LBL_x:LBL_VAL
Mapped MPLS label value
4096 × 2
MAP_RES_x (x= A or B)
Each of the two resources provide all of the fields listed. Two lookups are done in each resource for every
frame. This generates four mapping results per frame.
The four lookups implement mapping table 0 to 3. The address used for each lookup is controlled by the
ES0 actions MAP_n_KEY and MAP_n_IDX (n = 0:3).
A mapping table address consists of two parts:
•
•
A base index: ES0.MAP_n_IDX. This controls the MSB part of the table address.
One of 15 different keys that use classified frame properties to generate the LSB of the table
address. For more information about each key, see ES0 Configuration Registers, page 247.
The following illustration depicts the mapping table functionality.
Figure 71 • Mapping Tables
1 to 3 MPLS labels
LABEL
VCAP
ES0
ES0 Key
TC
S
TTL
Pushed Q-Tags
D
TPID
PCP E VID
I
Egress
OAM
IP Frame PDU-MOD
DSCP
OAM
Path Info
Table selector actions
for each field
SOC
Frame from OQS
ES0.map_idx(0,1)
Frame
Innermost TCI
Map Resource A
Address
IFH
ES0.map_key(0,1)
Table 0 fields
Addr Resource
A
Table 1 fields
SOC
Classified
fields
ES0.map_key(2,3)
Map Resource B
Address
ES0.map_idx(2,3)
Table 2 fields
Addr Resource
B
Table 3 fields
The mapping tables provide a flexible way to update frame fields. The following example shows how to
configure and use mapping table 1.
Update PCP in VLAN tag A using mapping table 1. Use frame DSCP as index:
•
•
•
•
Enable ES0
Program an ES0 key
Set ES0 action TAG_A_PCP_SEL to 5 for selected key
Set ES0 action PUSH_OUTER_TAG = 1
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
259
Functional Descriptions
•
•
•
•
Update PCP by using Table 1:
Select a base address in resource A. Base address 256 is used in this example
Set ES0 action MAP_1_IDX = 256/8 = 32
Use frame DSCP as key: Set ES0 action MAP_1_KEY = 2
Program the PCP mapping in table 1: Addr = 256 to 256 + 63 (all DSCP values)
Write REW:MAP_RES_A:$Addr/MAP_VAL_A PCP_VAL
Frame DSCP is used as key in this example. If the DSCP is not available (frame is non IP), the mapping
is considered invalid. and the PCP value is selected using this fallback method:
•
•
Use mapping table 1 if key is valid, otherwise use mapping table 0.
Use mapping table 0 if key is valid, otherwise use a fixed value.
In the example, a PCP value from table 0 is used instead for non IP frames, if the table 0 key is valid.
Otherwise, the ES0 action PCP_A_VAL is used. Mapping tables 2 and 3 have the same functionality.
Mapping tables 0 and 1 share the 4096 addresses available in Resource A. Table 2 and 3 share 4096
addresses in Resource B.
3.24.7
VLAN Editing
The rewriter performs five steps related to VLAN editing for each frame and destination:
1.
2.
3.
4.
5.
ES0 lookup. ES0 is looked up for each frame if enabled by the global configuration. The action from
ES0 controls the pushing of VLAN tags.
VLAN popping. Zero to three VLAN tags are popped from the frame. Popping is controlled from the
ANA by IFH.TAGGING.POP_CNT and by the action ES0.POP_VAL.
VLAN push decision. Decides the number of new tags to push and which tag source to use for each
tag. Tag sources are port, ES0 (tags A to C), and routing.
Constructs the VLAN tags. The new VLAN tags are constructed based on the tag sources’
configuration.
VLAN pushing. The new VLAN tags are pushed.
The outermost tag can optionally be controlled by port-based VLAN configuration.
Table 191 • Port VLAN Tag Configuration Registers
Register
Description
Replication
TPID_CFG.
TPID_VAL
Configures three custom TPID values.
These must be configured identically in
ANA_CL::VLAN_STAG_CFG.STAG_ETYPE_VAL.
3
PORT_VLAN_CFG
PORT_*
Port VLAN TCI.
Port _VID is also used for untagged set.
Ports
TAG_CTRL:
TAG_CFG_OBEY_
WAS_TAGGED
Controls how port tags are added. If this bit is set, the IFH field
Ports
VSTAX.TAG.WAS_TAGGED must be 1 before a port tag is added to a frame.
TAG_CTRL:
TAG_CFG
Controls port tagging. Four modes are supported.
Ports
TAG_CTRL:
TAG_TPID_CFG
Selects Tag Protocol Identifier (TPID) for port tagging.
Ports
TAG_CTRL:
TAG_VID_CFG
Selects VID in port tag.
Ports
TAG_CTRL:
TAG_PCP_CFG
Selects PCP fields in port tag.
Ports
TAG_CTRL:
TAG_DEI_CFG
Selects DEI fields in port tag.
Ports
DP_MAP.DP
Maps the four drop precedence levels (DP) to a drop eligible value (DE or
COLOR).
Global
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
260
Functional Descriptions
Table 191 • Port VLAN Tag Configuration Registers (continued)
Register
Description
Replication
PORT:
PCP_MAP_DEx
Mapping table. Maps DP level and QoS class to new PCP values.
Per port per
Q per DE
PORT:
DEI_MAP_DEx
Mapping table. Maps DP level and QoS class to new DEI values.
Per port per
Q per DE
3.24.7.1
ES0 Lookup
For each frame passing through the rewriter, an optional VCAP_ES0 lookup is done using the
appropriate key. The action from ES0 is used in the following to determine the frame’s VLAN editing.
3.24.7.2
VLAN Popping
The rewriter initially pops the number of VLAN tags specified by the IFH field IFH.TAGGING.POP_CNT
received with the frame. Up to three VLAN tags can be popped via the IFH. The rewriter itself can further
influence the number VLAN tags being popped by the ES0 action POP_VAL. This can increase the pop
count by one.
The rewriter analyzes the total number of tags in a frame, and this is the maximum number of tags that
can be popped regardless of the IFH and ES0 pop values.
3.24.7.3
VLAN Push Decision
After popping the VLAN tags, the rewriter decides to push zero to three new VLAN tags into the outgoing
frame according to the port’s tagging configuration in register TAG_CTRL.TAG_CFG and the action from
a potential VCAP ES0 hit.
Two additional tags can be added for mirrored or GCPU frames. These special tags will always be the
outermost ones. If MPLS encapsulation is added to a frame, the mirror or GCPU tags are placed after the
MPLS link layer SMAC.
Figure 72 • VLAN Pushing
DMAC
SMAC
0-2 GCPU or
Mirror Tags
Tag A
Outer Tag
(ES0, Port)
Tag B
Inner Tag
(ES0)
Tag C
Customer
Tag (ES0)
EtherType
Payload
Special tags(1)
Configurable port tag(2)
ES0 tag A
Force no tag (ES0)
Force port tag (ES0)
No tag
ES0 tag B
No tag
ES0 tag C
1. Mirror tag is controlled by REW::MIRROR_PROBE_CFG.REMOTE_MIRROR_CFG.
GCPU tag is controlled by REW::GCPU_CFG.GCPU_TAG_SEL.
2. Port tag is controlled by REW:PORT:TAG_CTRL.TAG_CFG.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
261
Functional Descriptions
The following table lists ES0 VLAN tag actions.
Table 192 • ES0 VLAN Tag Actions
ES0_ACTION
TAG_CFG
Tagging Action
No ES0 hit
Controls port tag The port tag is pushed according to TAG_CTRL.TAG_CFG as
outermost tag. The following options are available:
- Tag all frames with port tag.
- Tag all frames with port tag, except if classified VID = 0
or classified VID = PORT_VLAN_CFG.PORT_VID.
- Tag all frames with port tag, except if classified VID = 0.
TAG_CTRL.TAG_VID_CFG selects between classified- or
fixed-port VID.
No inner tag.
PUSH_OUTER_TAG = 0
PUSH_INNER_TAG = 0
Controls port tag Same as No ES0 hit action.
PUSH_OUTER_TAG = 1
PUSH_INNER_TAG = 0
Don’t care
ES0 tag A is pushed as outer tag.
No inner tag.
PUSH_OUTER_TAG = 2
PUSH_INNER_TAG = 0
Don’t care
Port tag is pushed as outer tag. This overrules port settings in
TAG_CFG.
No inner tag.
PUSH_OUTER_TAG = 3
PUSH_INNER_TAG = 0
Don’t care
No tags are pushed. This overrules port settings in TAG_CFG.
PUSH_OUTER_TAG = 0
PUSH_INNER_TAG = 1
Controls port tag Port tag is pushed according to TAG_CFG as outermost tag.
The following options are available:
- Tag all frames with port tag.
- Tag all frames with port tag, except if classified VID = 0 or
classified VID = PORT_TAG_DEFAULT.PORT_TCI_VID.
- Tag all frames with port tag, except if classified VID = 0.
- No port tag.
TAG_CTRL.TAG_VID_CFG select between classified- or fixedport VID.
ES0 tag B is pushed as inner tag.
ES0 tag B is effectively the outer tag if the port tag is not
pushed.
PUSH_OUTER_TAG = 1
PUSH_INNER_TAG = 1
Don’t care
ES0 tag A is pushed as outer tag.
ES0 tag B is pushed as inner tag.
PUSH_OUTER_TAG = 2
PUSH_INNER_TAG = 1
Don’t care
Port tag is pushed as outer tag. This overrules port settings in
TAG_CFG.
ES0 tag B is pushed as inner tag.
PUSH_OUTER_TAG = 3
PUSH_INNER_TAG = 1
Don’t care
No outer tag is pushed. This overrules port settings in
TAG_CFG.
ES0 tag B is pushed as inner tag.
ES0 tag B is effectively the outer tag, because no outer tag is
pushed.
Tag C is controlled separately and will always be the inner most tag.
All combinations of tags A to C are allowed.
PUSH_CUSTOMER_TAG = 0
Controls port tag Does not push customer tag (tag C).
PUSH_CUSTOMER_TAG = 1
Controls port tag Push tag C if IFH.VSTAX.TAG.WAS_TAGGED = 1.
PUSH_CUSTOMER_TAG = 2
Controls port tag Push tag C if IFH.VSTAX.TAG.WAS_TAGGED = 0.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
262
Functional Descriptions
Table 192 • ES0 VLAN Tag Actions (continued)
ES0_ACTION
TAG_CFG
PUSH_CUSTOMER_TAG = 3
Controls port tag 3: Push tag C if UNTAG_VID_ENA = 0 or (C-TAG.VID
! = VID_C_VAL) C-TAG.VID is controlled by TAG_C_VID_SEL.
UNTAG_VID_ENA
Controls port tag See PUSH_CUSTOMER_TAG = 3.
3.24.7.4
Tagging Action
Constructing VLAN Tags
The contents of the tag header are highly programmable when pushing a VLAN tag. The following
illustration shows the VLAN tag construction.
Figure 73 • VLAN Tag Construction
TPID
PCP
D
E
I
VID
0x8100
Mapped using ES0(2)
Classified + fixed(3)
0x88A8
(2)
Routing (VMID)
3xCustom
Classified
Fixed
Classified(1)
Fixed
PCP of popped tag
QoS class
Mapped DE, QoS
Mapped DE, COSID
Mapped DE, PCP
COSID
Mapped using ES0(2)
DEI of popped tag(2)
Classified
1. Classified using IFH 0x8100, 0x88A8,
or 3xCustom.
2. ES0 tag A to C.
3. For port tag, this is classified only.
Fixed
Color (DE)
Mapped DE, QoS
Mapped DE, COSID
Mapped DE, PCP
The port tags (ES0.PUSH_OUTER_TAG = [0[2]), the ES0 tags A to C, and the special tags have
individual configurations.
3.24.7.4.1 Port Tag: PCP
Use REW:PORT:TAG_CTRL.TAG_PCP_CFG to configure the following:
•
•
•
•
•
•
•
Use the classified PCP.
Use the egress port’s port VLAN (PORT_VLAN_CFG.PORT_PCP).
Use the QoS class directly.
Map DE and QoS class to a new PCP value using the per-port table PCP_MAP_DEx.
Map DE and COSID to a new PCP value using the per-port table PCP_MAP_DEx.
Map DE and classified PCP to a new PCP value using the per-port table PCP_MAP_DEx.
Use the COSID class directly.
3.24.7.4.2 Port Tag: DEI
Use REW:PORT_TAG_CTRL.TAG_DEI_CFG to configure the following:
•
•
•
•
Use the classified DEI.
Use the egress port’s port VLAN (PORT_VLAN_CFG.PORT_DEI).
Use mapped DP to DE level (color).
Map DE and QoS class to a new DEI value using the per-port table DEI_MAP_DEx.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
263
Functional Descriptions
•
•
Map DE and COSID to a new DEI value using the per-port table DEI_MAP_DEx.
Map DE and classified PCP to a new DEI value using the per-port table DEI_MAP_DEx.
3.24.7.4.3 Port Tag: VID
Use REW:PORT:TAG_CTRL.TAG_VID_CFG to configure the following:
•
•
•
Use the classified VID.
Use the egress port’s port VLAN (PORT_VLAN_CFG.PORT_VID).
Use VMID from router leg lookup. When L3 routing is active, the classified VID is overwritten by the
VMID.
3.24.7.4.4 Port Tag: TPID
Use REW:PORT:TAG_CTRL.TAG_TPID_CFG to configure the following:
•
•
•
•
Use Ethernet type 0x8100 (C-tag).
Use Ethernet type 0x88A8 (S-tag).
Use one of three custom TPIDs programmed in REW::TPID_CFG.TPID_VAL.
The TPID is classified by ANA and selected by IFH.
Similar options for the ES0 tag A to tag C are available:
3.24.7.4.5 ES0 Tag: PCP
Use ES0 action TAG_x_PCP_SEL to configure the following:
•
•
•
•
Use the classified PCP.
Use ES0_ACTION.PCP_x_VAL.
Use PCP of popped tag (IFH.VSTAX.TAG.WAS_TAGGED = 1 and num_popped_tags>0) else
PCP_x_VAL.
Use the complex mapping functionality provided by ES0 to lookup a PCP value.
3.24.7.4.6 ES0 Tag: DEI
Use ES0 action TAG_x_DEI_SEL to configure the following:
•
•
•
•
•
Use the classified DEI.
Use ES0_ACTION.DEI_x_VAL.
Use the complex mapping functionality provided by ES0 to lookup a DEI value.
Use DEI of popped tag (IFH.VSTAX.TAG.WAS_TAGGED = 1 and num_popped_tags>0) else
DEI_x_VAL.
Use the mapped DP to DE level (color) directly.
3.24.7.4.7 ES0 Tag: VID
Use ES0 action TAG_x_VID_SEL to configure the following:
•
•
Tag A and B: Use the classified VID incremented with ES0.VID_x_VAL.
Tag C: Use the classified VID.
Use ES0_ACTION.VID_x_VAL.
3.24.7.4.8 ES0 Tag: TPID
Use ES0 action TAG_x_TPID_SEL to configure the following:
•
•
•
•
Use Ethernet type 0x8100 (C-tag).
Use Ethernet type 0x88A8 (S-tag).
Use one of three custom TPIDs programmed in REW::TPID_CFG.TPID_VAL.
TPID is classified by ANA and selected via IFH.
GCPU or mirror forwarding can optionally insert additional tags. These will always be added as the
outermost tags. One or two special tags (A and B) can be added. The tag construction options as follows:
Special Tag A+B: PCP
•
•
Use the classified PCP.
Use fixed value.
Special Tag A+B: DEI
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
264
Functional Descriptions
•
Use fixed value.
Special Tag A+B: VID
•
Use fixed value.
Special Tag A+B: TPID
•
•
•
•
3.24.8
Use Ethernet type 0x8100 (C-tag).
Use Ethernet type 0x88A8 (S-tag).
Use one of three custom TPIDs programmed in REW::TPID_CFG.TPID_VAL.
TPID is classified by ANA and selected by means of IFH.
DSCP Remarking
The rewriter supports two DSCP remarking schemes. The first remarking mode is controlled by port and
IFH settings. The second remarking mode is controlled by ES0 actions and by the general mapping
tables.
DSCP actions from ES0 override any remarking done by the port.
3.24.8.1
ES0-Based DSCP Remarking
ES0 controls DSCP remarking if ES0 lookups are enabled and the DSCP_SEL action is different from 0.
For more information, see Mapping Tables, page 258.
3.24.8.2
Legacy Port-Based Mode
Simple DSCP remapping can be done using a common table shared by all ports.
The following table shows the port-based DSCP editing registers associated with remarking.
Table 193 • Port-Based DSCP Editing Registers
Register
Description
Replication
DP_MAP:DP
Maps the four drop precedence levels to a drop eligible value
(DE). DE is also called color.
Global
DSCP_REMAP:DSCP_REMAP
Full one-to one DSCP remapping table common for all ports.
None
DSCP_MAP: DSCP_UPDATE_ENA Selects DSCP from either frame or IFH.QOS.DSCP.
If DSCP_MAP.DSCP_UPDATE_ENA = 1 and
IFH.QOS.UPDATE_DSCP = 1: Selected
DSCP = IFH.QOS.DSCP
Else keep frame DSCP: Selected DSCP = Frame DSCP.
Ports
DSCP_MAP:DSCP_REMAP_ENA
Ports
Optionally remaps selected DSCP.
If DSCP_MAP.DSCP_REMAP_ENA = 1 and
IFH.QOS.TRANSPARENT_DSCP = 0: New DSCP =
DSCP_REMAP [Selected DSCP].
Else do no remap: New DSCP = selected DSCP.
The following remarking options are available.
•
•
•
•
No DSCP remarking. The DSCP value in the frame is untouched.
Update the DSCP value in the frame with the value received from the analyzer in IFH.QOS.DSCP.
Update the DSCP value in the frame with the frame DSCP mapped through
DSCP_REMAP.DSCP_REMAP.
Update the DSCP value in the frame with the value received from the analyzer (IFH.QOS.DSCP)
mapped through DSCP_REMAP.DSCP_REMAP.
The ANA can set IFH.QOS.TRANSPARENT_DSCP to prevent DSCP mapping even if this is enabled for
a port. The ANA can also force use of the frame DSCP for mapping by setting IFH.QOS.UPDATE_DSCP
to 0.
The IP checksum is updated when changing the DSCP for IPv4 frames.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
265
Functional Descriptions
3.24.9
VStaX Header Insertion
The rewriter controls insertion of the VStaX header. For more information about the header fields, see
VStaX Header, page 21.
The following registers are used for configuration of the rewriter specific stacking functionality.
Table 194 • Rewriter VStaX Configuration Registers
Register
Description
Replication
COMMON_CTRL.
OWN_UPSID
Configures own UPSID to be used for stacking.
None
CNT_CTRL.
VSTAX_STAT_ESDX_DIS
Configures ESDX counting for stacking ports.
If this bit is set and PORT_CTRL.VSTAX_HDR_ENA = 1, all counting
based on the ESDX value is disabled regardless of the
CNT_CTRL.STAT_MODE configuration.
None
PORT_CTRL.
VSTAX_STACK_GRP_SEL
Selects logical stacking port (or stacking port group) membership.
Ports
PORT_CTRL.
VSTAX_HDR_ENA
Enables insertion of stacking header in frame.
Ports
PORT_CTRL.
VSTAX_PAD_ENA
Enables padding of frames to 76 bytes.
Setting this bit will cause all frames on the port to be extended to 76
bytes instead of 64 bytes.
This should only optionally be enabled for stacking ports
(PORT_CTRL.VSTAX_HDR_ENA = 1). Setting this bit will prevent
frames from becoming under sized in a receiving switch, when the
VStaX header is removed. See
ASM::ERR_STICKY.FRAGMENT_STICKY.
Ports
PORT_CTRL.VSTAX2_MIRR
OR_OBEY_WAS_TAGGED
Configures tagging of frames with VSTAX.GEN.FWD_MODE =
VS2_FWD_GMIRROR. Only active on front ports for frames with this
FWD_MODE.
This is used to control the remote mirror tagging of frames that have
been mirrored from one unit in the stack to another unit.
Ports
PORT_CTRL.
VSTAX2_MISC_ISDX_ENA
Configures VSTAX MISC field decoding. Select between MISC- or AC
mode.
Ports
VSTAX_PORT_GRP_CFG.
VSTAX_TTL
Link TTL value.
2
VSTAX_PORT_GRP_CFG.
VSTAX_LRN_ALL_HP_ENA
Changes priority of learn all frames to the highest priority
(IFH.VSTAX.QOS = 7).
2
VSTAX_PORT_GRP_CFG.
VSTAX_MODE
Controls whether forwarding modes specific to VStaX AF are translated 2
to BF forwarding modes.
If set to 0, the following translation is performed:
fwd_logical -> fwd_lookup
fwd_mc -> fwd_lookup
If set to 1, no translation is performed.
Translation is only required for advanced forwarding switches operating
in a basic forwarding stack.
3.24.10 Forwarding to GCPU
The OQS can redirect CPU frames on selected CPU queues to the external ports instead of sending
them to the internal CPU. This is called GCPU forwarding and is typically used if an external CPU is
connected to the VSC7442-02, VSC7444-02, and VSC7448-02 devices through an Ethernet port.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
266
Functional Descriptions
GCPU forwarding is controlled per individual CPU queue. Stack ports have additional options for GCPU
forwarded frames.
Table 195 • GCPU Configuration Registers
Register
Description
GCPU_CFG.
GCPU_KEEP_IFH
Used when GCPU frames are forwarded to a front port.
Per CPU Q
Frames are sent with the IFH preserved. The IFH is encapsulated according
to the configuration. Setting GCPU_KEEP_IFH to a value different from 0
overrides the GCPU_TAG_SEL and GCPU_DO_NOT_REW settings for front
ports. No other rewrites are done to the frame.
The GCPU_KEEP_IFH setting is not active if PORT_CTRL.KEEP_IFH_SEL
is different from 0 or if PORT_CTRL.VSTAX_HDR_ENA = 1.
Replication
GCPU_CFG.
Used when GCPU frames are forwarded to a front port.
Per CPU Q
GCPU_DO_NOT_REW Frames are not modified when forwarded to the GCPU except for the optional
tags configured in GCPU_CFG.GCPU_TAG_SEL.
GCPU_CFG.
GCPU_TAG_SEL
The destination port type determines the functionality.
Per CPU Q
When a GCPU frame is forwarded to a stack port: Force a change of the
VSTAX.TAG to the configured values in GCPU_TAG_CFG:0.
When a GCPU frame is forwarded to a front port:
Optionally add one or two Q-tags to the frame. The tags are configured using
GCPU_TAG_CFG.
GCPU_CFG.
GCPU_FWD_MODE
Used when GCPU frames are forwarded to a stack port.
Per CPU Q
Configure forward mode of GCPU frames on stack ports by selecting value of
VSTAX.GEN.FWD_MODE.
CPU_CFG.
GCPU_UPSPN
Used when GCPU frames are forwarded to a stack port.
CPU QUEUE to be used as destination queue for global CPU transmission.
The value depends on configuration and the value of
GCPU_CFG.GCPU_FWD_MODE. Controls the value of
VSTAX.DST.DST_PN.
Per CPU Q
GCPU_CFG.
GCPU_UPSID
Used when GCPU frames are forwarded to a stack port.
UPSID to be used as destination in the VStaX header. Sets
VSTAX.DST.DST_UPSID to configured value.
Per CPU Q
GCPU_TAG_CFG.
TAG_TPID_SEL
Configuration of Q-Tags for GCPU frames.
GCPU frames that are forwarded to a front port can optionally have one or
two IEEE 802.3 VLAN tags added. The tags will be placed in the outer most
position after the SMAC.
GCPU VLAN tag Protocol Identifiers (TPID).
2
GCPU_TAG_CFG.
TAG_VID_VAL
GCPU VLAN VID value.
2
GCPU_TAG_CFG.
TAG_DEI_VAL
GCPU VLAN DEI values.
2
GCPU_TAG_CFG.
TAG_PCP_SEL
Selection of GCPU VLAN PCP values.
2
GCPU_TAG_CFG.
TAG_PCP_VAL
GCPU VLAN PCP values.
2
The IFH.MISC.CPU_MASK field is used to select the GCPU forwarding configuration. If multiple bits are
set in this mask, the most significant bit is always used to control the GCPU forwarding. The
ANA_AC::CPU_CFG.ONE_CPU_COPY_ONLY_MASK register is used to control how the CPU_MASK
is set before the frame enters the rewriter. If the CPU_MASK field is 0, all GCPU forwarding is disabled.
GCPU frame forwarding must be enabled in the OQS per CPU queue using the
QFWD::FRAME_COPY_CFG.FRMC_PORT_VAL registers.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
267
Functional Descriptions
3.24.11 Layer 3 Routing
The following registers are associated with routing (Layer 3, or L3). They are used when the analyzer
signals routing by setting IFH.FWD.DST_MODE = L3UC_ROUTING or L3MC_ROUTING.
The analyzer can also signal routing using IFH.DST.ENCAP.RT_FWD = 1. In this case, the MAC
addresses and VMIDs are controlled directly by the analyzer, and the registers in the rewriter are not
used.
Table 196 • Routing SMAC Configuration Registers
Register
Description
Replication
RLEG_CFG_0.
RLEG_MAC_LSB
Router Leg SMAC address used for IP routing (least significant bits).
Must be set identical to ANA_L3::RLEG_0.RLEG_MAC_LSB.
None
RLEG_CFG_1.
RLEG_MAC_TYPE_SEL
Configures how Router Leg MAC addresses are specified.
None
Must be set identical to ANA_L3::RLEG_CFG_1.RLEG_MAC_TYPE_SEL.
0: RLEG_MAC:= RLEG_MAC_MSB(23:0) and (RLEG_MAC_LSB(23:0) +
VMID(7:0) mod 224)
1: RLEG_MAC:= RLEG_MAC_MSB(23:0) and (RLEG_MAC_LSB(23:0) +
VID(11:0) mod 224
Others: RLEG_MAC:= RLEG_MAC_MSB(23:0) and
RLEG_MAC_LSB(23:0) number of common address for all VLANs.
RLEG_CFG_1.RLEG_MAC MSB part of SMAC used for IP routing.
_MSB
Must be set identical to ANA_L3::RLEG_MAC_MSB.
None
The IFH.DST.L3_[MC|UC]ROUTING.ERLEG fields are used to select the VID of routed frames using the
Egress Mapped VLAN (VMID) configuration registers listed in the following table.
Table 197 • L3 Routing Egress Mapping VLAN (EVMID)
Register
Description
Replication
RLEG_CTRL.RLEG_EVID
VID value assigned to this router leg.
128
RLEG_CTRL.
RLEG_VSTAX2_WAS_TAGGED
Control the value of IFH.VSTAX.TAG.WAS_TAGGED field in the 128
stack header for frames that are L3 forwarded to a stack port.
3.24.12 Mirror Frames
The devices offer three mirror probe sets that can be individually configured. The following table lists the
rewriter configuration registers associated with mirroring.
Table 198 • Mirror Probe Configuration Registers
Register
Description
Replication
MIRROR_PROBE_CFG.
MIRROR_TX_PORT
The Tx port for each mirror probe (from where rewrite configuration was Mirror probes
taken).
MIRROR_PROBE_CFG.
REMOTE_ENCAP_ID
Selects encapsulation ID to use for remote mirror frames.
Mirror probes
MIRROR_PROBE_CFG. Enables encapsulation of mirrored frames. One or two Q-tags (Q-in-Q) or
REMOTE_MIRROR_CFG the encapsulation table can be used.
In tag mode, the VLAN tags are added to the outer most position after the
SMAC. This also the case if a MPLS link layer is added to the frame. The
tags are then added after the LL-SMAC.
In encapsulation mode, an entry in the ENCAP table is used for
encapsulation. This overrides any encapsulation selected by ES0 for the
frame.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
268
Functional Descriptions
Table 198 • Mirror Probe Configuration Registers (continued)
Register
Description
Replication
MIRROR_TAG_x_CFG:
TAG_x_PCP_VAL
Mirror Q-tag PCP value.
2× mirror
probes
MIRROR_TAG_x_CFG:
TAG_x_PCP_SEL
Selection of mirror Q-tag PCP values.
2× mirror
probes
MIRROR_TAG_x_CFG:
TAG_x_DEI_VAL
Mirror Q-tag DEI values.
2× mirror
probes
MIRROR_TAG_x_CFG:
TAG_x_VID_VAL
Mirror Q-tag VID values.
2× mirror
probes
MIRROR_TAG_x_CFG:
TAG_x_TPID_SEL
The tag protocol identifier (TPID) for the remote mirror VLAN tag.
2× mirror
probes
The devices support mirroring frames from either Rx ports (ingress mirror) or Tx ports (egress mirror).
Frames either received on a port (Rx mirror) or frames sent to a port (Tx mirror) are copied to a mirror
destination port.
For Tx mirroring, the rewriter rewrites the frame sent to the mirror destination port, exactly as the original
frame copy is rewritten when forwarded to the mirror probe port. The mirror probe port number must be
configured in the rewriter using register MIRROR_TX_PORT.
For Rx mirroring, the rewriter makes no modifications to the frame, so an exact copy of the original frame
as received on the mirror probe port (ingress port) is sent out on the mirror destination port.
The analyzer controls both Rx and Tx mirroring. For more information, see Mirroring, page 205. The
rewriter obtains mirror information for the frame from the internal frame header.
IFH.FWD.MIRROR_PROBE indicates if the frame is a mirror copy and if so, to which of three mirror
probes the frame belongs. Encoding is as follows.
•
•
•
•
MIRROR_PROBE = 0: Frame is not a mirror copy
MIRROR_PROBE = 1: Frame is mirrored using mirror probe set 1
MIRROR_PROBE = 2: Frame is mirrored using mirror probe set 2
MIRROR_PROBE = 3: Frame is mirrored using mirror probe set 3
In addition, the IFH.FWD.RX_MIRROR bit indicates if the frame is Rx mirrored (1) or Tx mirrored (0).
When mirroring traffic to a device that is not directly attached to the VSC7442-02, VSC7444-02,
VSC7448-02, and VSC7449-02 device, it may be required to push one or two VLAN tags to mirrored
frame copies as to not violate general VLAN membership for the mirror destination port. These VLAN
tags are called “remote mirror VLAN tags” and can be configured individually for each mirror probe set.
When enabled, the remote mirror VLAN tags are pushed onto all mirrored traffic by the rewriter whether it
is an Rx mirrored frame or a Tx mirrored frame. For remote mirroring it is also possible to add MPLS
capsulation using the encapsulation table if this is required for forwarding the frame.
The REMOTE_MIRROR_ENA register configures whether to add one or two remote mirror VLAN tags or
MPLS encapsulation. The REMOTE_ENCAP_ID select the MPLS encapsulation to be used.
For Tx mirroring, care must be taken if maximum frame expansion is already required by the rewriter for
the TX mirror probe port. In this case enabling remote mirror VLAN tags or encapsulation would add an
extra frame expansion, which can cause frame disruption on the mirror destination port. It is not possible
to add remote mirror encapsulation to a frame that already has encapsulation added by ES0. In this case
the remote mirror encapsulation ID will replace the ID selected by the ES0.ENCAP_ID action.
3.24.13 Internal Frame Header Insertion
The rewriter can be configured to insert the internal frame header (IFH) into the frame upon transmission.
For more information about the IFH, Frame Headers, page 14.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
269
Functional Descriptions
Insertion of the IFH can be configured on any port, but it is intended for frames forwarded to the internal
CPU and the NPI port (external CPU). When IFH insertion is enabled on a given port, all frames leaving
that port contain the IFH.
The following table lists the registers for configuring the insertion of extraction IFH into the frame.
Table 199 • IFH Configuration Registers
Register
Description
Replication
PORT_CTRL.KEEP_IFH_SEL Configures the rewriter IFH mode for the port. See also
Ports
ASM::PORT_CFG.INJ_FORMAT_CFG.
0: Normal mode.
1: Keep IFH without modifications. Frames are not updated. IFH is
kept.
2: Encapsulate IFH. The frame’s DMAC, SMAC and a fixed TAG with
ETYPE = 8880 (Microsemi) and EPID=0x0007 are inserted in front of
the IFH: [FRM_DMAC][FRM_SMAC][0x8880][0x0007][IFH][FRAME].
3: Encapsulate IFH using the ENCAP table. Use ES0 to generate an
ENCAP_ID and insert the encapsulation in front of the
IFH:[ENCAP][IFH][FRAME]
The following illustration shows supported formats using KEEP_IFH_SEL.
Figure 74 • Supported KEEP_IFH_SEL Formats
KEEP_IFH_SEL = 0
IFH
DA
SA
Payload
F
C
S
KEEP_IFH_SEL = 1
Rewrite frame
IFH
DA
SA
Payload
F
C
S
Rewriter
KEEP_IFH_SEL = 2
KEEP_IFH_SEL = 3
DA
SA
Microsemi EtherType
and Protocol ID
Encapsulation
(ES0.ENCAP_ID)
IFH
DA
IFH
SA
DA
SA
Payload
Payload
F
C
S
F
C
S
Frames are always formatted using KEEP_IFH_SEL = 1 when extracting frames to the internal CPU
ports. This cannot be changed.
Note that for KEEP_IFH_SEL = 1, the frames transmitted on external ports are not valid Ethernet frames,
because the extraction IFH precedes the DMAC. As a result, this frame format must be used for direct
transmission to another VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 device or to a
dedicated FPGA or NPU. This format cannot be used for forwarding to a standard Ethernet device.
The frame formats using KEEP_IFH_SEL = 2 or KEEP_IFH_SEL = 3 are primarily used on a port that is
directly attached to an external CPU. When the IFH is included using these frame formats, the IFH is
included in the frame’s FCS calculation and a valid Ethernet frame is transmitted.
3.24.14 Frame Injection from Internal CPU
To instruct the switch core how to process the frame, the internal CPU injects frames to switch core using
the internal frame header. The format of injected frames from the internal CPU is similar to the
KEEP_IFH_SEL = 1 format.
On arrival to the rewriter, such injected frames are no different from any other frames. However, the IFH
contains information related to rewriter functionality specifically targeting efficient frame injection:
•
•
Do not rewrite (IFH.FWD.DO_NOT_REW):
If this injection IFH bit is set, the rewriter forward frames unchanged to the egress port no matter any
other rewriter configurations, except IFH.FWD.update_fcs.
Update frame check sequence (IFH.FWD.UPDATE_FCS):
If this injection IFH bit is set, the rewriter updates the FCS before forwarding a frame to the egress
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
270
Functional Descriptions
•
3.25
port. By setting this bit in the Injection IFH, the internal CPU can leave it to switch core hardware to
make sure the FCS value included with the frame is correct even though no other frame
modifications are performed by the switch core.
Swap MACs (IFH.DST.ENCAP.SWAP_MAC):
Swap MACs in the Ethernet link layer and clear bit 40 of the new SMAC before sending the frame to
the egress port. Swapping the MACs will also force the frame FCS to be updated. Cannot be used if
IFH.FWD.DO_NOT_REW = 1.
Disassembler
This section provides information about the disassembler (DSM) block. The disassembler is mainly
responsible for disassembling cells into Taxi words and forwarding them to the port modules. In addition,
it has several other responsibilities such as:
•
•
•
MAC Control sublayer PAUSE function with generation of PAUSE frames and stop forwarding traffic
on reception of PAUSE frames
Aging of frames that are stopped by flow control
Controlling transmit data rate according to IEEE802.3ar
The following table lists replication terminology.
Table 200 • Replication Terminology
3.25.1
Replication Terminology
Description
Replication Value
Per port
Per physical ports. For example, DEV1Gs, 55
DEV2G5s, DEV10Gs and CPU ports.
Setting Up Ports
In general, no additional configuration is required to bring up a port in the disassembler. However, the
following are some exceptions:
•
•
•
•
For the 10G capable ports, set DSM::BUF_CFG.CSC_STAT_DIS to 1 when the port is set up for
speeds above 2.5 Gbps, because the collection of statistics are handled locally in the DEV10G. For
lower speeds, the port uses a DEV2G5.
For 10G capable ports, set DSM::DEV_TX_STOP_WM_CFG.DEV_TX_STOP_WM to 3 if the port is
set up for 2.5 Gbps or 1 Gbps, and set it to 1 for 100 Mbps and 10 Mbps.
For 10G capable ports, set DSM::DEV_TX_STOP_WM_CFG.DEV10G_SHADOW_ENA to 1 when
port is set up for speeds below 10 Gbps.
For 10G capable ports, set DSM::SCH_STOP_WM_CFG.SCH_STOP_WM to 116.
Ports are indexed by 0 – 52 being front ports and 53 – 54 being CPU ports.
The following table lists the registers associated with setting up basic ports.
Table 201 • Basic Port Setup Configuration Registers Overview
Target::Register.Field
Description
Replication
DSM::BUF_CFG.CSC_STAT_DIS
Disables collection of statistics in the disassembler.
Per port
DSM::DEV_TX_STOP_WM_CFG.DEV Watermark for maximum fill level of port module TX
_TX_STOP_WM
buffer.
Per port
DSM::DEV_TX_STOP_WM_CFG.DEV Enable low speeds for 10G capable ports.
10G_SHADOW_ENA
Per port
3.25.2
Maintaining the Cell Buffer
The cell buffer is responsible for aligning and buffering the cell data received from the rewriter before the
data are forwarded on the Taxi bus.
The cell buffer can be flushed for each port separately.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
271
Functional Descriptions
The following table lists registers associated with configuring buffer maintenance.
Table 202 • Buffer Maintenance Configuration Register Overview
Target::Register.Field
Description
Replication
DSM::CLR_BUF.CLR_BUF
Flush the cell buffer.
Per port
Before a buffer is flushed, ensure that no data is forwarded to this port by stopping the QSYS forwarding
and disabling FC/PFC so that frames waiting for transmission will be sent. FC can be disabled in
DSM::RX_PAUSE_CFG.RX_PAUSE_EN.
3.25.3
Setting Up MAC Control Sublayer PAUSE Function
This section provides information about setting up the MAC control sublayer PAUSE function.
3.25.3.1
PAUSE Frame Generation
The main sources for triggering generation of PAUSE frames are the port level and buffer level
watermarks in the queue system. It is also possible to trigger PAUSE generation based on the analyzer
policing state.
For watermark-based PAUSE generation, a hysteresis is implemented. FC is indicated when the level of
used resources exceeds the high watermark and it is released when the level falls below the low
watermark. The following table lists the registers associated with configuration PAUSE frame generation.
Table 203 • PAUSE Frame Generation Configuration Registers Overview
Target::Register.Field
Description
Replication
DSM::ETH_FC_CFG.FC_ANA_ENA
Controls generation of FC based on FC request from the
analyzer.
Per port
DSM::ETH_FC_CFG.FC_QS_ENA
Controls the generation of FC based on FC request from
the queue system.
Per port
DSM::MAC_CFG.TX_PAUSE_VAL
The pause_time as defined by IEEE802.3 Annex 31B2
Per port
DSM::MAC_CFG.TX_PAUSE_XON_XOFF TX PAUSE zero on deassert.
Per port
DSM::MAC_ADDR_BASE_HIGH_CFG.
MAC_ADDR_HIGH
Bits 47-24 of SMAC address used in MAC_Control
frames.
Per port
DSM::MAC_ADDR_BASE_LOW_CFG.
MAC_ADDR_LOW
Bits 23-0 of SMAC address used in MAC_Control frames. Per port
DSM::MAC_CFG.TX_PAUSE_VAL defines the timer value for generated PAUSE frames. If the state
does not change by half of the time specified in this bit group, a new PAUSE frame is generated.
To generate a zero value pause frame when the reason for pausing has disappeared, set
DSM::MAC_CFG.TX_PAUSE_XON_XOFF to 1.
The DMAC of a generated pause frame is always the globally assigned 48-bit multicast address 01 80
C2 00 00 01.
The SMAC of a generated pause frame is defined by
DSM::MAC_ADDR_BASE_HIGH_CFG.MAC_ADDR_HIGH and
DSM::MAC_ADDR_BASE_LOW_CFG.MAC_ADDR_LOW.
3.25.3.2
Reaction on Received PAUSE Frame
The assembler detects received PAUSE frames and forwards the pause_time to the disassembler, which
stops data transmission (if enabled) for the period defined by pause_time. If PFC is enabled for a port,
then RX_PAUSE_EN must be disabled in the disassembler.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
272
Functional Descriptions
It is possible to configure the disassembler to not stop traffic locally but to instead forward the stop
information to the queue system. This is configured by setting
DSM::RX_PAUSE_CFG.FC_OBEY_LOCAL to 1.
Note that this behavior does not conform to IEEE 802.3, and the time until data transmission is stopped
is increased.
The following table lists the registers associated with configuring PAUSE frame reception.
Table 204 • PAUSE Frame Reception Configuration Registers Overview
Target::Register.Field
Description
Replication
DSM::RX_PAUSE_CFG.RX_PAUSE_EN
Enables flow control in Rx direction
Per port
DSM::RX_PAUSE_CFG.FC_OBEY_LOCAL
Configures whether flow control is obeyed locally in the Per port
disassembler or flow control information is sent to the
queue system.
3.25.3.3
PFC Pause Frame Generation
When PFC is enabled for a port, PFC PAUSE frames are generated when requested by the queue
system.
PFC is enabled on a per port basis in the disassembler. The queue system must also be setup to
generate PFC requests towards the disassembler. Regular flow control and PFC cannot operate
simultaneously on the same port. The available PFC configurations in the disassembler are listed in the
following table.
Table 205 • PFC PAUSE Frame Generation Configuration Registers Overview
Target::Register.Field
Description
Replication
DSM::ETH_PFC_CFG.PFC_MIN_
UPDATE_TIME
Minimum time between two PFC PDUs when PFC state changes Per port
after transmission of PFC PDU.
DSM::ETH_PFC_CFG.PFC_XOFF After sending PFC PDU with flow control deasserted for all
_MIN_UPDATE_ENA
priorities, enforces a PFC_MIN_UPDATE_TIME delay before
allowing transmission of next PFC PDU.
Per port
DSM::ETH_PFC_CFG.PFC_ENA
Per port
3.25.4
Enables PFC operation for the port.
Setting up Flow Control in Half-Duplex Mode
The following table lists the configuration registers for half-duplex mode flow control. For more
information about setting up flow control in half-duplex mode, see PAUSE Frame Generation, page 272.
Table 206 • Half-Duplex Mode Flow Control Configuration Register Overview
Target::Register.Field
Description
Replication
DSM::MAC_CFG.HDX_BACKPRESSURE
Enables HDX backpressure instead of FDX FC when
FC is generated.
Per port
To enable half-duplex flow control, DSM::MAC_CFG.HDX_BACKPRESSURE must be set to 1. In this
mode, the disassembler forwards the FC status to the port modules, which then collides incoming
frames.
3.25.5
Setting Up Frame Aging
The following tables provide the aging configuration and status register settings. If frame aging is
enabled, the disassembler discards frames that are stuck, for example, due to flow control or frames that
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
273
Functional Descriptions
are received from the queue system with an era value eligible for aging. Frames discarded by aging are
counted in DSM::AGED_FRMS.AGED_FRMS_CNT.
Table 207 • Aging Configuration Register Overview
Target::Register.Field
Description
Replication
DSM::BUF_CFG.AGING_ENA
Enable aging of frames stuck in the disassembler buffer system for
long periods.
Per port
Table 208 • Aging Status Register Overview
Target::Register.Field
Description
DSM::AGED_FRMS.AGED_FRMS_CNT Count number of aged frames.
3.25.6
Replication
Per port
Setting Up Transmit Data Rate Limiting
The disassembler can limit the transmit data rate as specified in IEEE802.3ar, which defines the
following three rate limiting methods. The disassembler allows enabling of any combination of the
following three methods.
•
•
•
Frame overhead
Payload data rate
Frame rate
The following table lists the registers associated with rating limiting.
Table 209 • Rate Limiting Common Configuration Registers Overview
Target::Register.Field
Description
Replication
DSM::TX_RATE_LIMIT_MODE.
TX_RATE_LIMIT_ACCUM_MODE_ENA
Enables for accumulated rate limit mode.
Per port
DSM::TX_RATE_LIMIT_MODE.
PAYLOAD_PREAM_CFG
Defines whether the preamble is counted as payload in
txRateLimitPayloadRate and txRateLimitFrameRate
mode.
Per port
DSM::TX_RATE_LIMIT_MODE.
PAYLOAD_CFG
Defines if what is configured as header size in
TX_RATE_LIMIT_HDR_SIZE::
TX_RATE_LIMIT_HDR_CFG is subtracted form the
payload.
Per port
DSM::TX_RATE_LIMIT_MODE.
IPG_SCALE_VAL
Scales the IPG calculated by txRateLimitFrameOverhead Per port
and/or txRateLimitPayloadRate by a power of 2.
DSM::TX_RATE_LIMIT_HDR_CFG.
TX_RATE_LIMIT_HDR_SIZE
Defines how much of the frame is seen as header and not per port
counted as payload.
If more than one of the rate limiting modes previously mentioned are enabled, the additional inter-packet
gap is the maximum of each of the values generated by one of the enabled modes. However, if only the
frame overhead and the data payload data rate modes are enabled, the additional inter-packet gap can
be calculated as the sum of the additional gaps retrieved from each of the two modes. To enable the
function, set DSM::TX_RATE_LIMIT_MODE.TX_RATE_LIMIT_ACCUM_MODE_ENA to 1.
If the preamble of a frame is not to be counted as payload, set
DSM::TX_RATE_LIMIT_MODE.PAYLOAD_CFG to 0.
In addition, if parts of the frame are to be seen as header and not counted as payload, set
DSM::TX_RATE_LIMIT_MODE.PAYLOAD_CFG to 1.
DSM::TX_RATE_LIMIT_HDR_CFG.TX_RATE_LIMIT_HDR_SIZE defines how much of the frame that
should be considered as header. Note that this register is global for all ports enabled by
DSM::TX_RATE_LIMIT_MODE.PAYLOAD_CFG. The payload configuration applies to Payload Data
Rate and Frame Rate mode.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
274
Functional Descriptions
To enable bandwidth limiting down to very low data rates, the calculated IPG can be scaled. In other
words, multiplied by a power of 2 in the range 2 to 1,024. By this it is possible to limit the data rate down
to 2.3% (for 1536 byte frames).
3.25.6.1
Setting Up Frame Overhead
The following table lists the frame overhead configuration registers.
Table 210 • Rate Limiting Frame Overhead Configuration Registers Overview
Target::Register.Field
Description
Replication
DSM::TX_RATE_LIMIT_MODE.
TX_RATE_LIMIT_FRAME_OVERHEAD_ENA
Enable txRateLimitFrameOverhead mode.
Per port
DSM::RATE_CTRL.FRM_GAP_COMP
Inter-packet gap to be used.
Per port
To increase the minimum inter-packet gap for all packets, set
DSM::TX_RATE_LIMIT_MODE.TX_RATE_LIMIT_FRAME_OVERHEAD_ENA to 1, and set
DSM::RATE_CTRL.FRM_GAP_COMP to a value between 13 to 255.
For more information about the scaling feature if the GAP must be above 255, see Setting Up Transmit
Data Rate Limiting, page 274.
3.25.6.2
Setting Up Payload Data Rate
The following table lists the payload data rate configuration registers.
Table 211 • Rate Limiting Payload Data Rate Configuration Registers Overview
Target::Register.Field
Description
Replication
DSM::TX_RATE_LIMIT_MODE.
TX_RATE_LIMIT_PAYLOAD_RATE_ENA
Enable txRateLimitPayloadRate mode.
Per port
DSM::TX_IPG_STRETCH_RATIO_CFG.
TX_FINE_IPG_STRETCH_RATIO
Stretch ratio.
Per port
To limit the data rate relative to the transmitted payload, set
DSM::TX_RATE_LIMIT_MODE.TX_RATE_LIMIT_PAYLOAD_RATE_ENA to 1.
The inter-packet gap increase can be expressed as:
ΔIPG = 2S × (256/R) × L
Where:
S: Scaling factor DSM::TX_RATE_LIMIT_MODE.IPG_SCALE_VAL
R: Stretch ratio
DSM::TX_IPG_STRETCH_RATIO_CFG.TX_FINE_IPG_STRETCH_RATIO
L: Payload length, possibly modified according to
DSM::TX_RATE_LIMIT_MODE.PAYLOAD_PREAM_CFG and
DSM::TX_RATE_LIMIT_MODE.PAYLOAD_CFG
Note: Total IPG is 12 byte standard IPG plus IPG.
Values for R must not be below 1152 or above 518143.
Values for S must not be above 10.
Fractional parts of the resulting IPG value are carried forward to the next IPG.
Higher values for S allow for finer target accuracy/granularity on the cost of an increased IPG jitter.
The utilization can be expressed as:
U = L / (L + IPG) or
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
275
Functional Descriptions
U = R / (R + 2S × 256)
3.25.6.3
Setting Up Frame Rate
The following table lists the frame rate configuration registers.
Table 212 • Rate Limiting Frame Rate Registers Overview
Target::Register.Field
Description
Replication
DSM::TX_RATE_LIMIT_MODE.
TX_RATE_LIMIT_FRAME_RATE_ENA
Enables txRateLimitFrameRate mode.
Per port
DSM::TX_FRAME_RATE_START_CFG.
TX_FRAME_RATE_START
Frame rate start.
Per port
To define a minimum frame spacing, set
DSM::TX_RATE_LIMIT_MODE.TX_RATE_LIMIT_FRAME_RATE_ENA to 1.
At start of payload, a counter is loaded with the value stored in
DSM::TX_FRAME_RATE_START_CFG.TX_FRAME_RATE_START.
What is counted as payload is defined by DSM::TX_RATE_LIMIT_MODE.PAYLOAD_PREAM_CFG and
DSM::TX_RATE_LIMIT_MODE.PAYLOAD_CFG.
With every payload byte transmitted, the counter is decremented by 1.
At end of frame, the GAP will be extended by the counter value, if above 12.
3.25.7
Error Detection
The following table lists the error detection status registers.
Table 213 • Error Detection Status Registers Overview
Target::Register.Field
Description
Replication
DSM::BUF_OFLW_STICKY.BUF_OFLW_STICKY
Cell buffer had an overflow.
Per port
DSM::BUF_UFLW_STICKY.BUF_UFLW_STICKY
Cell buffer had an underrun.
Per port
DSM::TX_RATE_LIMIT_STICKY.TX_RATE_LIMIT_ IPG was increased by one of the three rate
STICKY
limiting modes.
Per port.
If one or both of BUF_OFLW_STICKY and BUF_UFLW_STICKY sticky bits are set, the port module was
set up erroneously.
TX_RATE_LIMIT_STICKY is set when an IPG of a frame is increased due to one of the three rate limiting
modes.
3.26
Layer 1 Timing
There are five recovered clock outputs that provide timing sources for external timing circuitry in
redundant timing implementations. The following tables list the registers and pins associated with Layer 1
timing.
Table 214 • Layer 1 Timing Configuration Registers
Register
Description
HSIO::SYNC_ETH_CFG
Configures recovered clock output. Replicated per recovered clock output.
HSIO::SYNC_ETH_PLL2_CFG
Additional PLL2 recovered clock configuration.
HSIO::SYNC_ETH_SD10G_CFG Additional 10G recovered clock configurations. Replicated per SERDES10G.
HSIO::PLL5G_CFG3
Enables high speed clock output.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
276
Functional Descriptions
Table 215 • Layer 1 Timing Recovered Clock Pins
Pin Name
I/O
Description
RCVRD_CLK0
O
Recovered clock output, configured by SYNC_ETH_CFG[0].
RCVRD_CLK1
O
Recovered clock output, configured by SYNC_ETH_CFG[1].
RCVRD_CLK2
O
Recovered clock output, configured by SYNC_ETH_CFG[2].
RCVRD_CLK3
O
Recovered clock output, configured by SYNC_ETH_CFG[3].
CLKOUT2
O
PLL2 high speed clock output.
It is possible to recover receive timing from any 10/100/1000 Mbps, 2.5 Gbps, XAUI, RXAUI, or SFI data
streams into the devices. For QSGMII links, timing must be recovered in the PHY, because the QSGMII
link retimes during aggregation of data streams.
The SYNC_ETH_CFG register provides per recovered clock divider configuration, allowing division by
one, four, or five before sending out clock frequency.
The recovered clock outputs have individual divider configuration (through SYNC_ETH_CFG) to allow
division of SerDes receive frequency by one, four, or five. In addition to the output dividers, the SFI 10G
sources have local pre-dividers to allow adjustments for the SFI links 64/66 encoding overhead by
extending clock cycles.
The recovered clocks are single-ended outputs. The suggested divider settings in the following tables are
selected to make sure to not output too high frequency via the input and outputs.
Ports operating in 1 Gbps or lower speeds allow recovery of 125 MHz clocks. Configure the ports as
shown in the following table.
Table 216 • Recovered Clock Settings for 1 Gbps or Lower
Port
Output Frequency
Register Settings for Output n
0–23
125 MHz
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=0, and
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=(DEV+1)
0–23
31.25 MHz
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=2, and
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=(DEV+1)
24–31
125 MHz
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=0, and
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=(DEV+5)
24–31
31.25 MHz
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=2, and
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=(DEV+5)
48
125 MHz
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=0, and
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=0
48
31.25 MHz
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=2, and
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=0
49–52
125 MHz
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=0,
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=(DEV-24), and
SYNC_ETH_SD10G_CFG[DEV49].SD10G_RECO_CLK_DIV=0
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
277
Functional Descriptions
Table 216 • Recovered Clock Settings for 1 Gbps or Lower
Port
Output Frequency
Register Settings for Output n
49–52
31.25 MHz
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=2,
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=(DEV-24), and
SYNC_ETH_SD10G_CFG[DEV49].SD10G_RECO_CLK_DIV=0
Ports operating in 2.5 Gbps mode allow recovery of a 125 MHz or 156.25 MHz clock, depending on the
port type. The following table shows the configuration settings.
Table 217 • Recovered Clock Settings for 2.5 Gbps
Port
Output Frequency
Register Settings for Output n
8–23
31.25 MHz
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=1, and
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=(DEV+1)
24–31
31.25 MHz
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=1, and
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=(DEV+5)
48
31.25 MHz
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=1, and
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=0
49–52
31.25 MHz
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=2,
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=(DEV-24), and
SYNC_ETH_SD10G_CFG[DEV49].SD10G_RECO_CLK_DIV=1
Ports operating in XAUI or RXAUI modes allow recovery of a 156.25 MHz clock. Configure as shown in
the following table.
Table 218 • Recovered Clock Settings for XAUI/RXAUI
Port
Output Frequency
Register Settings for Output n
49
31.25 MHz
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=1, and
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=29
50
31.25 MHz
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=1, and
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=33
41
31.25 MHz
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=1, and
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=17
52
31.25 MHz
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=1, and
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=21
Ports operating in SFI mode allow two base frequencies: One derived directly from the line rate and one
that is adjusted for the 64/66 encoding overhead. The latter is generated by extending every sixteenth
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
278
Functional Descriptions
clock cycle by half a clock-period. While this introduces jitter, it makes the frequency compatible with the
other recovered clocks. Configure as described in the following table.
Table 219 • Recovered Clock Settings for SFI
Port
Output Frequency
Register Settings for Output n
49–52
~161 MHz
(10.3125 GHz/64)
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=0,
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=(DEV-24), and
SYNC_ETH_SD10G_CFG[DEV-49].SD10G_RECO_CLK_DIV=1.
49–52
156.25 MHz
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=0,
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=(DEV-24), and
SYNC_ETH_SD10G_CFG[DEV-49].SD10G_RECO_CLK_DIV=2.
Synthesized by extending every 16th clock cycle by 1/2 period.
49–52
~32 MHz
(10.3125 GHz/320)
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=(DEV-24), and
SYNC_ETH_SD10G_CFG[DEV-49].SD10G_RECO_CLK_DIV=1.
49–52
31.25 MHz
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=(DEV-24), and
SYNC_ETH_SD10G_CFG[DEV-49].SD10G_RECO_CLK_DIV=2
Synthesized by extending (approximately) every third clock cycle by 1/10th period.
The frequency of the secondary PLL can be output as recovered clock. The following table shows the
configurations.
Table 220 • Recovered Clock Settings for Secondary PLL
PLL
Output Frequency
Register Settings for Output n
#2
125 MHz
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=0,
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=37,
SYNC_ETH_PLL2_CFG.CLKOUT2_DIV=5, and
SYNC_ETH_PLL2_CFG.PLL2_RECO_CLK_DIV=1
#2
31.25 MHz
SYNC_ETH_CFG[n].RECO_CLK_ENA=1,
SYNC_ETH_CFG[n].SEL_RECO_CLK_DIV=2,
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC=37,
SYNC_ETH_PLL2_CFG.CLKOUT2_DIV=5, and
SYNC_ETH_PLL2_CFG.PLL2_RECO_CLK_DIV=1
The recovered clock from PLL 2 can be sent directly out on the differential high-speed CLKOUT2
outputs. The recovered clock frequency is controlled by SYNC_ETH_PLL2_CFG.CLKOUT2_DIV
(SYNC_ETH_PLL2_CFG.PLL2_RECO_CLK_DIV does not apply to CLKOUT2). To enable CLKOUT2,
set HSIO:PLL_CFG[1]:PLL5G_CFG3.CLKOUT2_SEL = 3.
It is possible to automatically squelch the clock output when the devices detect a loss of signal on an
incoming data stream. This can be used for failover in external timing recovery solutions.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
279
Functional Descriptions
The following table lists how to configure squelch for possible recovered clock sources (configured in
SYNC_ETH_CFG[n].SEL_RECO_CLK_SRC).
Table 221 • Squelch Configuration for Sources
SRC
Associated Squelch Configuration
0–8
Set SERDES1G_COMMON_CFG.SE_AUTO_SQUELCH_ENA in SD macro to enable squelch
when receive signal is lost. SD1G macro index is the same as SRC.
9–24
Set SERDES6G_COMMON_CFG.SE_AUTO_SQUELCH_ENA in SD macro to enable squelch
when receive signal is lost. SD6G macro-index is (SRC-9).
25–28
Set SYNC_ETH_SD10G_CFG[(SRC-25)].SD10G_AUTO_SQUELCH_ENA to enable squelch
when receive signal is lost.
29–36
Set SERDES6G_COMMON_CFG.SE_AUTO_SQUELCH_ENA in SD macro to enable squelch
when receive signal is lost. SD6G macro-index is (SRC-13).
37
Set SYNC_ETH_PLL2_CFG.PLL2_AUTO_SQUELCH_ENA to enable squelch when PLL 2 loses
lock.
When squelching the clock it will stop when detecting loss of signal (or PLL lock). The clock will stop on
either on high or low level.
3.27
Hardware Time Stamping
Hardware time stamping provides nanosecond-accurate frame arrival and departure time stamps, which
are used to obtain high precision timing synchronization and timing distribution, as well as significantly
better accuracy in performance monitoring measurements than what is obtained from pure software
implementations.
The hardware time stamping functions operate both on standalone devices and in systems where
multiple devices are interconnected to form a multichip system.
Figure 75 • Supported Time Stamping Flows
1588-enabled
Switch or PHY
Interconnect
Front Port
Device
Front Port
Interconnect
1588-enabled
Switch or PHY
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
280
Functional Descriptions
Hardware time stamping can update PTP frames coming from a standard front port without any 1588
support or from a partner device that does parts of the timing update. Each port is configured according
to the partner device attached.
The modes defined in the following table comply with commonly used methods of transferring timing
information in a multichip system, but are as such not specified in the IEEE 1588 standard.
The time of day counters are generated in the DEVCPU block where there are various means of
accurately updating the time. For more information, see Time of Day Generation, page 285. The output
from the DEVCPU block is a set of timing parameters listed in the following table.
Table 222 • Timing Parameters
Parameter
Description
NSF (32 bit)
Counts number of nanoseconds since PTP was enabled in the device. Wraps at 232.
TOD_nsec (30 bit)
Counts the number of nanoseconds of current time of day. Wraps at 109, and will potentially be
in synch with the partner devices.
TOD_secs (48 bit)
Counts number of seconds of current time of day. Wraps at 248.
NSX48
Counts number of nanoseconds. NSX48 always take the value of TOD_nsec + TOD_sec*109.
The parameter is to be used for time stamping transfer to partner devices.
NSX32/NSX44
The lower 32 or 44 bits of NSX48.
The PTP frame flow through the device is shown in the following illustration.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
281
Functional Descriptions
Figure 76 • Frame Flow
Rx Port
Rx delay
SERDES
PCS
Rx stamp (NSF)
MAC
ANA
SQS
REW
PTP
REW stamp
(all counters)
Tx FIFO
PTP
Tx stamp (NSF)
MAC
Tx delay
PCS
SERDES
Tx Port
The time stamps generated by the ports are samples of the NSF value. The ingress time is the time at
which the PCS sees the start of frame, synchronized to the system clock domain. The correct 1588
ingress time is the time at which the first bit of the DMAC is received on the SERDES interface so a preconfigured delay is used to adjust for this in the time stamp calculations. The subtraction of the delay is
done by the port modules. Delays due to barrel shifting are adjusted by a manual process, where the
barrel shifter state must be read out and used when configuring the port’s I/O delays. For more
information, see Configuring I/O Delays, page 289.
Similarly, in the egress direction, a delay is added to the time stamps in order to move the time stamping
point to when the first bit of the DMAC leaves the SerDes. This added delay takes place in the port
modules.
The analyzer recognizes the PTP frames through VCAP IS2 matching and decides which operation to
perform (one-step, two-step, or time-of-day-write) and which delays to add to the correction field (CF) to
adjust for instance for asymmetrical path delays.
The rewriter modifies the PTP frame and can instruct the egress port module to add a delay to the
correction field corresponding to the delay from the rewriting point to the transmission point. Otherwise, it
can insert the original time stamp and the egress time stamp in a time stamp FIFO, which can be read by
the CPU. The rewriter operation depends on the analyzer decisions and the PTP modes of the frame’s
ingress and egress ports.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
282
Functional Descriptions
The following table lists the PTP configuration available to the rewriter.
Table 223 • Rewriter PTP Configuration
Field
Description
MR
Mode of ingress port.
MT
Mode of egress port.
IDLY(2)
Two ingress delays optionally added to CF. Looked up for the ingress port. Format
is 32 bits signed.
EDLY
One egress delay optionally added to CF. Looked up for the egress port. Only one
delay is added per transfer. Format is 32 bits signed.
UDP_CSUM_DIS(4/6)
Can disable updating the UDP checksums in IPv4 and IPv6 frames.
3.27.1
One-Step Functions
The mode of a port determines how timing information is exchanged between the port and its link partner.
Only the rewriter uses this information for executing the correct calculations and for deciding the right
delta command to be executed in the egress port module. When the analyzer has decided to do a onestep timing update of a frame, the rewriter updates the correction field to the time at which it passes
through the rewriter, and it will afterwards either prepare the PDU with timing information for the link
partner, or it will ask the port module to add the time delay to the serial transmission onto the correction
field. The following sections describe the PTP port modes used by the rewriter when doing one-step
updates.
3.27.1.1
Front
Front ports are ports on the boundary of the local PTP system. Frames received must have their timing
information updated to the time at which they left the link partner, and frames transmitted will likewise be
updated to the time of transmission.
3.27.1.2
RSRV32
In a multichip system, the RSRV32 mode can be used for interconnect links. The ingress unit must
update the CF field with the residence time from ingress link to any point in the ingress unit, and in the
RSRV field of the PDU set the value of NSX32 at the time of CF update. As the egress unit in a multichip
system has synchronized NSX32 (common clock by some means), it will be able to update the CF field
with time passed from the ingress rewriter to the time of system departure.
3.27.1.3
RSRV30
Similar to the mode RSRV32, but the reference point is moved to the time of departure from the egress
unit. The time value to use in the reserved bytes field only is the TOD_nsec value instead of NSX32.
3.27.1.4
ADDS48
The interconnect link in this mode carries frames where the ingress time in NSX48 format is subtracted
from the CF field. Likewise, the egress unit will add the NSX48 at time of departure. This is accomplished
by the following steps.
•
•
•
•
3.27.1.5
Ingress rewriter: CF is added time from ingress port to rewriter (NSF delta)
Ingress rewriter: CF is subtracted NSX value when doing the rewrite
Egress rewriter: CF is added NSX value when doing the rewrite
Egress port: CF is added time from rewriter to departure (NSF delta)
ADDS44
This mode operates as the ADDS48, only NSX44 is used instead. In this mode the egress unit must be
able to see that the NSX44 has wrapped since the ingress unit did the subtraction, ie. if the NSX44 at
ingress was 0xFFF.FFFF.FFFF, and at egress is 0x000.0000.0132, a larger value was subtracted than
added. This is handled by the ingress unit setting CF(46) to the NSX48(44) value, and the egress unit
checking the same to see if NSX48(44) has changed. In that case 244 is added to CF.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
283
Functional Descriptions
3.27.1.6
MONITOR
This mode is used for an egress port where we want the frame to be updated to the time of reception
only. This is used for CPU ports, where software must be able to compare the frame time with the local
time stamp, in order to detect drift. It can also be used for mirroring ports where it is desired to see what
time was carried on frames received from an interconnect. When a frame is transmitted on a MONITOR
port, the frame will be calculated up to the ingress time stamping point. The frame will be added selected
delay (IDLY/EDLY), but will not take any chip internal residence time in as a contributor to the CF.
3.27.1.7
DISABLED
A disabled PTP port is not updating PTP frames at all. This mode only applies to the destination port. If
the ingress PTP mode is set to disabled, it is treated as being a FRONT port.
3.27.2
Calculation Overview
The modes of ingress and egress ports determine which PTP calculations to do. The calculations are
split in an ingress half updating the frame to the time at which it passes the central rewriter and an egress
half, where residence time from the rewriter is prepared and finalized in the egress port module or on the
other side of the link (backplane).
In all cases the selected delay is added to CF (IDLY/EDLY).
If the ingress port mode is misconfigured as being DISABLED or MONITOR, it will be handled as a
FRONT port.
The port module is through an internal preamble instructed to either do a delta update of the correction
field only (CF), or to do a delta update of both the correction field and the reserved bytes field
(CF_RSRV). In both cases the rewriter NSF value is sent along as a reference for the delta delay
calculation in the port.
Table 224 • Rewriter Operations for One-Step Operation
Mode
Receiving From
Transmitting To
FRONT
CF += (NSF – IFH.STAMP)
Preamble = (CF, NSF)
RSRV30
CF += (NSEC – PDU.RSRV)
PDU.RSRV = NSEC
Preamble = (CF_RSRV, NSF)
RSRV32
CF += (NSX32 – PDU.RSRV)
PDU.RSRV = NSX32
ADDS44
CF += (NSX44@rew)
CF += (CF_org(46)/=NSX48(44))?244:0
CF(46) = CF(47)
CF –=NSX44 CF(46) = NSX48(44)
ADDS48
CF += NSX48
CF –= NSX48
MONITOR
CF –= (NSF – IFH.TSTAMP)
DISABLED
NOP
3.27.3
Detecting Calculation Issues
A sticky bit per port informs if frames are received with the reserved bytes field non-zero. This can be
used to detect if incoming frames contain unexpected information in the reserved bytes field.
If the correction field is outside the valid range –247 to 247–1, another sticky bit is set in the port module
indicating the overflow. The port module replaces in this case the final CF with the overflow indication
value 247–1. This detection is however disabled when using ADDS48 mode because the correction field
in this mode rolls over regularly.
3.27.4
Two-Step Functions
The two-step PTP mode uses software as a middle stage for informing next hubs about residence times.
A FIFO of time stamping events is available for software where ingress and egress time stamps as well
as port numbers can be read out. The FIFO can contain 1,024 time stamp entries.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
284
Functional Descriptions
Figure 77 • Time Stamp Bus and FIFO
DEV_0
ooo
TsBus
DEV_1
TsBus
DEV_n
Tx=0
Ingress
PortNo
Ingress
Timestamp
Tx=1
Egress
PortNo
Egress
Timestamp
TS FIFO
To S/W
REW
The bus passes through all port modules and terminates in a timestamp FIFO in the rewriter. If the
analyzer has decided to do a two-step operation, the rewriter pushes two entries into the FIFO. The first
entry contains the egress time stamp and the egress port number; the second entry contains the ingress
time stamp and the ingress port number. In addition, a flag indicates whether the entry contains ingress
or egress information.
When correlating frames copied to the CPU with entries in the FIFO, the ingress time stamp found in the
IFH is the same as ingress time stamp found in the FIFO.
Note that the IDLY and EDLY values are not added to the CF field in the two-step case, as the frames are
transferred untouched. Software must manually add these delays for the follow-up frames.
3.27.5
Time of Day Time Stamping
When sending out SYNC frames with full TOD, the rewriter does the TOD time stamping at the time
where the frame passes through the rewriter and the port module is instructed to do a one-step update in
addition. The transmitted SYNC therefore has ORG_TIME=’close to departure time’, and CF=’minor
correction to that’.
REW: PDU.ORGTIME := (TOD_sec, TOD_nsec)
REW: Preamble := (CF, NSF)
DEV: CF += NSF@mac_Tx-ofs
3.27.6
Time of Day Generation
The DEVCPU has connection to four GPIOs to be used for 1588 synchronization shown in the following
illustration.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
285
Functional Descriptions
Figure 78 • Timing Distribution
Five controllers configured for:
- Load absolute time
- Load signed delta time
- Store absolute time
- Generate pulse or clock on pin
Load/store can be done on incoming edge
or immediately.
Adjuster
GPIO
LoadStore
Ctrl
LoadStore
Ctrl
LoadStore
LoadStoreCtrl
Ctrl
load
AbsT
gen
store
DeltaT
gen
TimeOfDay
sec (48 bits)
nsec (30 bits)
nsf (32 bits)
ooo
TimeOfDay
TimeOfDay
Analyzer / Rewriter / Port Modules
(only NSF in port module)
Each block using timing has a TimeOfDay instance included. These modules let time pass according to
an incoming delta request, instructing it to add the nominal clock period in nanoseconds (+0/+1/–1) for
each system clock cycle. This is controlled by a deltaT function in the DEVCPU, which can be configured
to do regular adjustments to the time by adding a single nanosecond more or less at specified intervals.
The absT function in the DEVCPU can set the full TOD time in the system. This is controlled by the
LoadStore controllers.
The DEVCPU includes five LoadStore controllers. All but the last one use a designated GPIO pin on the
GPIO interface. LoadStore controller 0 uses PTP_0 pin; LoadStore controller 1 uses PTP_1 pin, and so
forth. Before using the LoadStore controller, the VCore-III CPU must enable the overlaid functions for the
appropriate GPIO pins. For more information, see GPIO Overlaid Functions, page 354.
Each controller has CPU accessible registers with the full time of day set, and can be configured to load
these into the TimeOfDay instances, or to store the current values from them. The operation can be done
on a detected edge on the associated pin or immediately. The GPIO pin can also generate a clock with
configurable high and low periods set in nanoseconds using the TimeOfDay watches or it can generate a
pulse at a configured time with a configurable duration and polarity.
Table 225 • LoadStore Controller
Pin Control Field
Function
Action
Load: Load TOD_SEC and TOD_NSEC through the absTime bus
Delta: Add configured nsec to the current time of day (absT).
Store: Store the current TOD_SEC,TOD_NSEC,TOD_NSF.
Clock: Generate a clock or a pulse on the pin.
Sync
Execute the load/store on incoming edge, if action is LOAD or STORE.
Generate a pulse instead of clock if action is CLOCK.
Inverse polarity
Falling edges are detected/generated.
TOD_sec
The 48-bit seconds of a time of day set to be loaded or stored.
TOD_nsec
The 30-bit nanoseconds of a time of day set to be loaded or stored.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
286
Functional Descriptions
Table 225 • LoadStore Controller (continued)
Pin Control Field
Function
TOD_NSF
The 32-bit free running timer to be stored (no load of that one)
Waveform high
Number of nanoseconds in the high period for generated clocks.
Duration of pulse for generated pulse.
Waveform_low
Number of nanoseconds in the low period for generated clocks.
Delay from TOD_ns = 0 for generated pulse.
In addition, the load operation can load a delta to the current time. This is done by executing a LOAD
action but using the DELTA command (see register list).
Each operation generates an interrupt when executed. For the clock action, the interrupt is generated
when the output switches to the active level. The interrupts from each controller can be masked and
monitored by the interrupt controller in the ICPU_CFG register target.
The five controllers are completely equal in their capabilities. For concatenated distributed TC
applications, two of the controllers are set up in STORE/sync mode, where incoming edges on the pin
make the Time of day be stored in the controller registers.
3.27.7
Multiple PTP Time Domains
For communicating with link partners running in another TOD domain, the devices include three PTP
time domains. Each port belongs to one domain only, and by default, all ports belong to time domain 0.
Other time domains are accessed by configuring the time domain in the port modules, the analyzer, the
rewriter, and the Loadstore controllers.
3.27.8
Register Interface to 1588 Functions
The following table lists the blocks and register configurations associated with IEEE 1588 functionality.
Table 226 • IEEE 1588 Configuration Registers Overview
Block
Configurations
Analyzer
PTP actions in VCAP IS2.
Rewriter
Path and asymmetry delays
Enabling use of preamble
Setting PTP port mode/options
Accessing time stamp FIFO
Port modules
Enable rewriting. Read barrel shifter states for accuracy.
I/O delays.
Per port SMAC for address replacing.
CPU device
Controlling TOD generation.
3.27.8.1
VCAP IS2 Actions
In the analyzer, the VCAP IS2 actions are related to PTP operation. The REW_CMD action field
determines the PTP actions in the rewriter.
Table 227 • PTP Actions in Rewriter
Action Bits
Description
1-0: PTP command
0: No operation.
1: One-step.
2: Two-step.
3: Time of day.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
287
Functional Descriptions
Table 227 • PTP Actions in Rewriter (continued)
Action Bits
Description
3–2: Delay command
0: Do not add any delays.
1: Add PTP_EDLY(Tx port).
2: Add PTP_IDLY1(Rx port).
3: Add PTP_IDLY2(Rx port).
5–4: Sequence number and
time stamp command
0: No operation.
1: Sequence update. The rewriter contains a table of 256 sequence numbers which
can be selected by the lower bits of the time stamp field from the IFH. If this command
bit is set, the selected sequence number is put into the PDU, and the sequence will be
incremented by one. Feature only makes sense when frame is injected by the CPU, in
which case the IFH can be fully controlled by injecting with IFH.
2-3: Delay_Req/Delay_Resp processing. These modes are handled in the analyzer.
This is used for automatic response generation without involving software. If bits 1-0
are set to one-step, the rewriter is requested to update the CF field to the time of
reception.
6: SMAC to DMAC
If set, copy the SMAC into the DMAC of the frame.
7: Configuration to SMAC
If set, set the SMAC to the PTP SMAC configured per egress port.
3.27.8.2
Rewriter Registers
The following table lists registers associated with time stamping.
Table 228 • Rewriter Registers
Register
Description
PTP_MODE_CFG
Assign time domain and PTP port mode for each port.
PTP_EDLY_CFG
PTP_IDLY1_CFG
PTP_IDLY2_CFG
Configure ingress and egress optional delays to use per port.
PTP_SMAC_LSB
PTP_SMAC_MSB
Configure the optional SMAC to replace in the PDUs.
PTP_MISC_CFG
Disable UDP checksum updating per port.
PTP_TWOSTEP_CTRL
Get next time stamp from FIFO.
PTP_TWOSTEP_STAMP
Next time stamp value.
PTP_CPUVD_MODE_CFG
Set mode and time domain for CPU and virtual device ports.
PTP_RSRV_NOT_ZERO
Sticky bit for incoming non-zero reserved bytes field.
PTP_SEQ_NO
Set or get sequence number for 256 flows.
3.27.8.3
Port Module Registers
The following table lists the port module registers associated with time stamping.
Table 229 • Port Module Registers
Register
Description
PTP_CFG
Set I/O delays for port, enable PTP, and set port’s time domain.
PTP_EVENTS
Sticky bit for correction field overflow.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
288
Functional Descriptions
3.27.9
Configuring I/O Delays
After a valid link is established and detected by the involved PCS logic, the I/O delays from the internal
time stamping points to the serial line must be configured. The delays are both mode-specific and
interface-specific, depending on the core clock frequency.
Ingress barrel shifter states that in SERDES1G mode, the Rx delays must be added 0.8 ns times the
value of PCS1G_LINK_STATUS.DELAY_VAR to adjust for barrel shifting state after link establishment. In
SERDES2.5G, the multiplier is 0.32 ns. In SERDES100M, the Rx delays must be subtracted 0.8 ns times
the value of PCS_FX100_STATUS.EDGE_POS_PTP to adjust for detected data phase.
The following tables provides the Rx and Tx delay times on the ports.
Table 230 • I/O Delays at 250 MHz
Port Number
SERDES 100M
Rx/Tx
SERDES1G
Rx/Tx
SERDES2.5G
Rx/Tx
SERDES10G
Rx/Tx
0–7, 48
84.0/72.3
63.0/32.3
8–15
94.0/81.6
71.1/41.7
31.9/12.2
16–23
94.0/97.6
71.1/57.7
31.9/18.8
24–31
110.0/97.6
87.1/57.7
38.1/18.8
49–52
134.5/105.3
115.7/64.9
49.7/22.0
122.9/151.0
SERDES2.5G
Rx/Tx
SERDES10G
Rx/Tx
Table 231 • I/O Delays at 278 MHz
3.28
Port Number
SERDES 100M
Rx/Tx
SERDES1G
Rx/Tx
0–7, 48
84.2/72.9
61.9/34.2
8–15
93.7/81.5
70.2/42.1
30.8/13.4
16–23
93.7/97.5
70.2/58.1
30.8/19.7
24–31
109.7/97.5
86.8/58.1
37.3/19.7
49–52
133.0/105.7
115.4/65.1
37.3/19.7
122.6/151.8
VRAP Engine
The Versatile Register Access Protocol (VRAP) engine allows external equipment to access registers in
the devices through any of the Ethernet ports on the devices. The VRAP engine interprets incoming
VRAP requests, and executes read, write, and read-modify-write commands contained in the frames.
The results of the register accesses are reported back to the transmitter through automatically generated
VRAP response frames.
The devices support version 1 of VRAP. All VRAP frames, both requests and responses, are standard
Ethernet frames. All VRAP protocol fields are big-endian formatted.
The registers listed in the following table control the VRAP engine.
Table 232 • VRAP Registers
Register
Description
Replication
ANA_CL:PORT:CAPTURE_CFG.
CPU_VRAP_REDIR_ENA
Enable redirection of VRAP frames to
CPU.
Per port
ANA_CL::CPU_PROTO_QU_CFG.
CPU_VRAP_QU
Configure the CPU extraction queue for None
VRAP frames.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
289
Functional Descriptions
Table 232 • VRAP Registers (continued)
Register
Description
Replication
QFWD:SYSTEM:FRAME_COPY_CFG.
FRMC_PORT_VAL
Map VRAP CPU extraction queue to a
CPU port. One CPU port must be
reserved for VRAP frames.
Per CPU
extraction
queue
DEVCPU_QS:XTR:XTR_GRP_CFG.MODE
Enable VRAP mode for reserved CPU
port.
Per CPU port
DEVCPU_QS:INJ:INJ_GRP_CFG.MODE
Enable VRAP mode injection for
reserved CPU port.
Per CPU port
ASM:CFG:PORT_CFG.INJ_FORMAT_CFG
The IFH without prefix must be present Per port
for VRAP response frames.
ASM:CFG:PORT_CFG.NO_PREAMBLE_ENA
Expect no preamble in front of IFH and Per port
frame.
DEVCPU_GCB::VRAP_ACCESS_STAT
VRAP access status.
None
The VRAP engine processes incoming VRAP frames that are redirected to the VRAP CPU extraction
queue by the basic classifier. For more information about the VRAP filter in the classifier, see CPU
Forwarding Determination, page 110.
The VRAP engine is enabled by allocating one of the two CPU ports as a dedicated VRAP CPU port
(DEVCPU_QS:XTR:XTR_GRP_CFG.MODE and DEVCPU_QS:INJ:INJ_GRP_CFG.MODE). The VRAP
CPU extraction queue (ANA_CL::CPU_PROTO_QU_CFG.CPU_VRAP_QU) must be mapped as the
only CPU extraction queue to the VRAP CPU port
(QFWD:SYSTEM:FRAME_COPY_CFG.FRMC_PORT_VAL). In addition, the VRAP CPU port must
enable the use of IFH without prefix and without preamble (ASM::PORT_CFG)
The complete VRAP functionality can be enabled automatically at chip startup by using special chip boot
modes. For more information, see VCore-III Configurations, page 306.
3.28.1
VRAP Request Frame Format
The following illustration shows the format of a VRAP request frame.
Figure 79 • VRAP Request Frame Format
VRAP Commands
DMAC
SMAC
EtherType
EPID
Any valid DMAC
Any valid SMAC
0x8880
0x0004
VRAP HDR
(Request)
48 bits
48 bits
16 bits
16 bits
32 bits
#1
FCS
#n
variable length
Valid FCS
32 bits
VRAP request frames can optionally be VLAN tagged with one VLAN tag.
The EtherType = 0x8880 and the Ethernet Protocol Identifier (EPID) = 0x0004 identify the VRAP frames.
The subsequent VRAP header is used in both request and response frames.
The VRAP commands included in the request frame are the actual register access commands. The
VRAP engine supports the following five VRAP commands:
•
•
•
•
•
READ: Returns the 32-bit contents of any register in the device.
WRITE: Writes a 32-bit value to any register in the device.
READ-MODIFY-WRITE: Does read/modify/write of any 32-bit register in the device.
IDLE: Does not access registers; however, it is useful for padding and identification purposes.
PAUSE: Does not access registers, but causes the VRAP engine to pause between register access.
Each of the VRAP commands are described in the following sections. Each VRAP request frame can
contain multiple VRAP commands. Commands are processed sequentially starting with VRAP command
1, 2, and so on. There are no restrictions on the order or number of commands in the frame.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
290
Functional Descriptions
3.28.2
VRAP Response Frame Format
DMAC
SMAC from
VRAP request frame
SMAC
DMAC from VRAP
request frame
EtherType
EPID
0x8880
0x0004
VRAP HDR
(Response)
48 bits
48 bits
16 bits
16 bits
32 bits
READ and IDLE results
#1
#n
variable length
FCS
Valid FCS
32 bits
The VRAP response frame follows the VRAP request frame in terms of VLAN tagging: If the VRAP
request was tagged, the VRAP response is also tagged using the same VLAN.
Only the READ and IDLE commands require data to be returned to the transmitter of the VRAP request
frame. However, even if the VRAP request frame does not contain READ and IDLE commands, a VRAP
response frame is generated with enough padding data (zeros) to fulfill the minimum transfer unit size.
3.28.3
VRAP Header Format
Both VRAP request and VRAP response frames contain a 32-bit VRAP header. The VRAP header is
used to identify the protocol version and to differentiate between VRAP requests and VRAP response
frames. VSC7442-02, VSC7444-02, and VSC7448-02 support VRAP version 1. A valid VRAP request
frame must use Version = 1 and Flags.R = 1. Frames with an invalid VRAP header are discarded and not
processed by the VRAP engine. The following illustration shows the VRAP header.
Figure 80 • VRAP Header Format
4 bits
4 bits
24 bits
Version
Flags
Reserved
31
28 27
24 23
0
Version:
Set to 0x1 in VRAP response frames.
VRAP request frames are ignored if Version 1
Flags:
4 bits are used for Flags. Only one flag is defined:
R
Rsv
3
0
R: 0=Request, 1=Response
Rsv: Set to 0 in VRAP response frames and ignored in VRAP
request frames.
Reserved:
Set to 0 in VRAP response frames and ignored in VRAP
request frames.
3.28.4
VRAP READ Command
The VRAP READ command returns the contents of any 32-bit register inside the device. The 32-bit readdata result is put into the VRAP response frame.
The READ command is 4 bytes wide and consists of one 32-bit address field, which is 32-bit aligned. The
2 least significant bits of the address set to 01. The following illustration shows the request command and
the associated response result.
Figure 81 • READ Command
Request:
Response:
Register address, bits 31:2
32 bits
01
Register read data
32 bits
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
291
Functional Descriptions
Figure 82 • WRITE Command
Request:
Register address, bits 31:2
10
Register write data
32 bits
3.28.5
32 bits
VRAP READ-MODIFY-WRITE Command
The READ-MODIFY-WRITE command does read/modify/write-back on any 32-bit register inside the
device.
The READ-MODIFY-WRITE command is 12 bytes wide and consists of one 32-bit address field, which is
32-bit aligned. The two least significant bits of the address set to 11 followed by one 32-bit write-data field
followed by one 32-bit overwrite-mask field. For bits set in the overwrite mask, the corresponding bits in
the write data field are written to the register while bits cleared in the overwrite mask are untouched when
writing to the register. The following illustration shows the command.
Figure 83 • READ-MODIFY-WRITE Command
Request:
Register address, bits 31:2
11
Register write data
Overwrite mask
32 bits
32 bits
32 bits
3.28.6
VRAP IDLE Command
The IDLE command does not access registers in the device. Instead it just copies itself (the entire
command) into the VRAP response. This can be used for padding to fulfill the minimum transmission unit
size, or an external CPU can use it to insert a unique code into each VRAP request frame so that it can
separate different replies from each other.
The IDLE command is 4 bytes wide and consists of one 32-bit code word with the four least significant
bits of the code word set to 0000. The following illustration depicts the request command and the
associated response.
Figure 84 • IDLE Command
Request:
Response:
Any 28-bit value
0000
32 bits
3.28.7
Copy of value
0000
32 bits
VRAP PAUSE Command
The PAUSE command does not access registers in the device. Instead it causes the VRAP engine to
enter a wait state and remain there until the pause time has expired. This can be used to ensure
sufficient delay between VRAP commands when this is needed.
The PAUSE command is 4 bytes wide and consists of one 32-bit code word with the four least significant
bits of the code word set to 0100. The wait time is controlled by the 28 most significant bits of the wait
command. The time unit is 1 us. The following illustration depicts the PAUSE command.
Figure 85 • PAUSE Command
Request:
Pause value (µs)
0100
32 bits
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
292
Functional Descriptions
3.29
Energy Efficient Ethernet
The Ethernet ports support Energy Efficient Ethernet (EEE) to reduce power consumption when there is
little or no traffic on a port.
The state diagram in the following illustration shows the EEE LPI algorithm implemented in the devices.
Figure 86 • EEE State Diagram
LPI
EMPTY
Port has frame(s) for
transmission
LPI
NONEMPTY
Port queue(s) in
OQS exceed
FWD_PRESS_THRES
watermark
EEE_TIMER_AGE passed
OR
Port queue(s) in OQS exceed
FWD_PRESS_THRES watermark
ACTIVATING
EEE_TIMER_WAKEUP passed
ACTIVE
NONEMPTY
Transmitting
Port has no frames for
transmission
Port has frame(s) for
transmission
ACTIVE
EMPTY
EEE_TIMER_HOLDOFF passed
•
•
•
•
•
LPI_EMPTY: Low power mode. Port has no frames for transmission.
LPI_NONEMPTY: Low power mode. Port has frames for transmission, but the number of frames is
very limited (below EEE_URGENT_THRES in OQS) or EEE_TIMER_AGE has not passed yet.
ACTIVATING: Port is being activated prior to restarting frame transmission. The timer
EEE_TIMER_WAKEUP controls the length of the activation time.
ACTIVE_NONEMPTY: Port is active and transmitting. This is the normal state for ports without EEE
enabled.
ACTIVE_EMPTY: Port is active, but currently has no frames for transmission. If frames for
transmission do not become available within EEE_TIMER_HOLDOFF, then the port enters low
power mode (in state LPI EMPTY).
The state transition timing values are configured in the EEE_CFG register per port module, and the
levels at which the queue system asserts forward pressure are configured in the QSYS::EEE_CFG and
QSYS::EEE_THRES registers.
As illustrated, the “port has frames for transmission” condition is true if there are frames for transmission
and the scheduling algorithm allows transmission of any of the available frames. So it is possible that a
port enters LPI_EMPTY or stays in LPI_EMPTY, even though there are frames in one or more queues.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
293
Functional Descriptions
It is also possible, though not likely, that forward pressure is set for one or more queues when going into
LPI_EMPTY. This occurs when the scheduling algorithm has decided to transmit from other queue or
queues than those signalling forward pressure and the transmission of these frames causes the port
leaky bucket to close.
The “forward pressure signalled for queues” condition does not look at whether the queues with forward
pressure are actually allowed to transmit.
For ports that are shaped to a low bandwidth, the forward pressure watermark in OQS should be set a
low value, such that it is mainly the port shaping that controls when to exit LPI.
3.30
CPU Injection and Extraction
This section provides an overview of how the CPU injects and extracts frames to and from the switch
core.
The switch core forwards CPU extracted frames to eight CPU extraction queues that per queue are
mapped to one of the two CPU ports (by means of QFWD:SYSTEM:FRAME_COPY_CFG[0:7]) that the
CPU can access. For each CPU extraction queue, it is possible to specify the egress priority
(QFWD:SYSTEM:FRAME_COPY_CFG.FRMC_QOS_ENA). For each CPU port, there is strict priority
selection between the egress queues.
For injection, there are two CPU injection groups that can simultaneously forward frames into the
analyzer. The CPU can access the injection and extraction groups through either a Frame DMA or direct
register access.
For more information about injecting and extracting CPU traffic through front ports used as NPI port, see
Internal Frame Header Placement, page 15; Setting Up a Port for Frame Injection, page 53; and
Forwarding to GCPU, page 266.
3.30.1
Frame Injection
The traffic at any injection pipeline point from CPU, NPI, and AFI using the IFH
(IFH.MISC.PIPELINE_ACT:= INJ_MASQ and IFH.MISC.PIPELINE_PT: = ).
When a frame is injected at a given pipeline point, it is logically not processed in the flow before reaching
the injection point. For example, a frame injected at the ANA_CLM pipeline point bypasses VRAP
detection, port Down-MEP handling, and basic classification, which requires the frame to be injected with
an IFH configured with all the fields normally set by Basic classification. It also means that the frame is
not accounted for in port Down-MEP loss measurement counters.
Injecting a frame at the ANA_DONE pipeline point causes it to bypass the complete analyzer and
destination port must be specified in IFH (IFH.MISC.DPORT = ).
Frames can be injected as either unicast or as multicast:
•
Unicast injection that allows injection into a single egress port (configured in IFH.MISC.DPORT) with
all IFH.DST.ENCAP operators available in the Rewriter such as OAM and PTP detection and
hardware handling (if IFH.FWD.DST_MODE is set to ENCAP).
Multicast injection that allows injection to multiple egress ports (IFH.FWD.DST_MODE = INJECT and
IFH.DST.INJECT.PORT_MASK). Because IFH.DST is used for specifying the destination set, it is not
possible to use IFH.DST.ENCAP for this type of injection and all IFH.DST.ENCAP fields will default to 0.
This mode bypasses the analyzer, meaning that all IFH fields used by rewriter must be given a proper
value by software.
3.30.1.1
Masqueraded Injection
The devices support masqueraded injection of frames from CPU where processing of the frame is done
as if the frame was received on the masqueraded port (IFH.MISC.PIPELINE_ACT=INJ_MASQ and
IFH.FWD.SRC_PORT=). A masquerade-injected frame sees the same source filter,
classification, and learning as the physical port being masqueraded.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
294
Functional Descriptions
3.30.1.2
Injection Pipeline Points
The devices support specifying where in the processing flow a frame is injected by specifying a pipeline
point for the frame (IFH.MISC.PIPELINE_PT). The frame will then only be processed after the specified
injection point.
3.30.2
Frame Extraction
The CPU receives frames through eight CPU extraction queues. These extraction queues can be
mapped to one of the two CPU ports or any of the front ports (QFWD:SYSTEM:FRAME_COPY_CFG[07]). The CPU extraction queues use memory resources from the shared queue system and are subject to
the thresholds and congestion rules programmed for the CPU extraction queues and the shared queue
system in general.
A frame can be extracted for multiple reasons. For example, a BPDU with a new source MAC address
can be extracted as both a BPDU and a learn frame with two different CPU extraction queues selected.
By default, the highest CPU extraction queue number receives a copy of the frame, but it is also possible
to generate multiple frame copies to all the selected CPU extraction queues
(ANA_AC::CPU_CFG.ONE_CPU_COPY_ONLY_MASK).
The CPU can read frames from the CPU port in two ways:
•
•
Reading registers in the CPU system. For more information, see Manual Extraction, page 332.
Using the Frame DMA in the CPU system. For more information, see FDMA Extraction, page 331.
CPU extracted frames include an IFH (28-bytes) placed in front of the DMAC. The IFH contains relevant
side band information about the frame, such as the frame’s classification result (VLAN tag information,
DSCP, QoS class) and the reason for sending the frame to the CPU. For more information about the
contents of the IFH, Frame Headers, page 14.
3.30.3
Forwarding to CPU
Several mechanisms can be used to trigger redirection or copying of frames to the CPU. The following
blocks can generate traffic to a CPU queue.
•
•
•
•
•
•
Analyzer classifier ANA_CL
Analyzer Layer 3 ANA_L3
Analyzer Access Control Lists ANA_ACL
Analyzer Layer 2 ANA_L2
Analyzer Access Control ANA_AC
Rewriter
Frames copied or redirected to the CPU from both the rewriter and the Up-MEPs are looped and passed
another time through the analyzer.
3.30.4
Automatic Frame Injection (AFI)
The AFI block supports repeated (automated) injection, which requires the injection frame to be sent to
the AFI block with a single IFH bit set (IFH.FWD.AFI_INJ) and with an IFH header configured as for
normal CPU injection.
After an injection frame is sent to the AFI block, the frame can be added for AFI injection. For more
information, see Adding Injection Frame, page 244.
Frames injected from the AFI block are treated as any CPU injection, where IFH fields controls how injection occurs.
Frames from the AFI can either be injected directly into an egress port or they can appear as if they were
received on an ingress port (masquerading). Masqueraded frames are subsequently processed by the
analyzer like any other frame received on the port.
3.31
Priority-Based Flow Control (PFC)
Priority-based flow control (PFC, IEEE 802.1Qbb) is supported on all ports for all QoS classes. The
devices provide independent support for transmission of pause frames and reaction to incoming pause
frames, which allows asymmetric flow control configurations.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
295
Functional Descriptions
3.31.1
PFC Pause Frame Generation
The queue system monitors the congestion per ingress and egress queue. If a flow control condition is
asserted, the queue system forwards the congestion status to the disassembler. The disassembler
stores the congestion status per (port, priority). Based on the congestion status, the disassembler will
transmit PFC frames for each port.
3.31.1.1
Queue System
The queue system has a set of dedicated PFC watermarks. If the memory consumption of a queue
exceeds a PFC watermark, a flow control condition is asserted, and the updated congestion status is
forwarded the disassembler. For information about the configuration of the PFC watermarks, see PriorityBased Flow Control, page 217.
3.31.1.2
Disassembler
The disassembler (DSM) stores the congestion status per queue (per port, per priority) and generates
PFC PDU based on the information. For more information about the available PFC configuration
registers, see PFC Pause Frame Generation, page 273.
The following illustration shows the algorithm controlling the generation of PFC frames for each port. The
8-bit congestion state from the queue system is fc_qs. TX_PAUSE_VAL and PFC_MIN_UPDATE_TIME
are configurable per port. The TX_PAUSE_VAL configuration is shared between LLFC and PFC.
When a priority gets congested, a PFC PDU is generated to flow control this priority. When half of the
signaled timer value has expired, and the queue is still congested, a new PFC PDU is generated. If other
priorities get congested while the timer is running, then PFC_MIN_UPDATE_TIME is used to speed up
the generation of the next PFC PDU. The timer is shared between all priorities per port.
Every PFC PDU signals the flow control state for all priorities of the port. In other words, the
priority_enable_vector of the PFC PDU is always set to 0x00ff, independent of whether or not a priority is
enabled for flow control. For disabled priorities, the pause time value is always set to 0.
Figure 87 • PFC Generation per Port
FC Inactive
fc_qs != 0x00
&&
(timer == 0 || !PFC_XOFF_MIN_UPDATE_ENA)
Transmit PFC PDU
(xoff)
timer =
PFC_MIN_UPDATE_TIME
Transmit PFC PDU
fc_txed = fc_qs
timer = TX_PAUSE_VAL
timer < TX_PAUSE_VAL/2
fc_qs == 0x00
&&
timer < (TX_PAUSE_VAL –
PFC_MIN_UPDATE_TIME)
PFC Sent
fc_qs unchanged
fc_qs == fc_txed
fc_qs != fc_txed
fc_qs != 0x00
&&
timer < (TX_PAUSE_VAL –
PFC_MIN_UPDATE_TIME)
PFC Sent
fc_qs changed
fc_qs: Congestion state per priority from QS
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
296
Functional Descriptions
3.31.1.3
Statistics
The number of transmitted pause frames is counted in the TX_PAUSE_CNT counter and shared with the
counter for transmitted link-layer flow control pause frames. Statistics are handled locally in the DEV10G
port modules. For other port module types, the assembler handles the statistics.
3.31.2
PFC Frame Reception
Received PFC frames are detected by the assembler. The status is forwarded to the queue system,
which will pause the egress traffic according to the timer value specified in the pause frames.
3.31.2.1
Assembler
The assembler identifies PFC PDUs and stores the received pause time values in a set of counters. The
counters are decremented according to the link speed of the port. The assembler signals a stop
indication to the queue system for all (port, priority) with pause times different from 0.
For information about the PFC configuration of the assembler, see Setting Up PFC, page 54.
3.31.2.2
Queue System
The queue system stores the PFC stop indications received from the assembler per (port, priority). It
pauses the transmission for all egress queues with an active PFC stop indication. The queue system
does not require any PFC configuration.
3.31.2.3
Statistics
PFC pause frames are recognized as control frames and counted in the RX_UNSUP_OPCODE_CNT
counter. Statistics are handled locally in the DEV10G port modules. For other port module types, the
assembler handles the statistics.
3.32
Protection Switching
The following types of hardware-assisted protection switching are supported:
•
•
Ethernet ring protection switching
Port protection switching
Ring protection is also supported over a link aggregation group (LAG).
3.32.1
Ethernet Ring Protection Switching
When protection switching occurs in an Ethernet ring (ITU-T G.8032), the following actions must be taken
to restore connectivity.
•
•
MAC addresses learned on the ring ports for the involved FIDs must be flushed from the MAC table.
This is done using the scan functionality in the LRN block. Using
ANA_L2:COMMON:SCAN_FID_CFG.SCAN_FID_VAL MAC, addresses for up to 16 FIDs can be
flushed at a time.
The RPL port must be changed to forwarding state and ports interfacing to the failed link must be
changed to blocking state. For rings supporting many VLANs, this can be done efficiently using
VLAN TUPE.
The following illustration shows an Ethernet ring protection example. Switch A is part of two rings, ring 1
and ring 2. Ring 1 uses 18 VIDs, VID 4-19 and 31-32, for forwarding traffic. Ring 2 uses 32 VIDs, VID 1030 and 40-50.
To allow a VLAN TUPE command to identify the VIDs used by each of the two rings, a bit in the
TUPE_CTRL field in the VLAN table is allocated for each of the two rings. In this example, ring 1 uses bit
0 in TUPE_CTRL, and ring 2 uses bit 1.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
297
Functional Descriptions
Figure 88 • Ethernet Ring Protection Example
Ethernet Switch A
0
1
2
3
4
5
6
7
8
Ring protectionlink (RPL)
Ethernet
Switch
B
Ring 1
VLANs: 4-19, 31-32
Ethernet
Switch
D
Ethernet
Switch
E
Ring 2
VLANs: 10-30, 40-50
Ethernet
Switch
G
Ethernet
Switch
F
RPL port
Ring protection link (RPL)
Ethernet
Switch
C
The following table shows the configuration of the VLAN table of switch A. The VLAN_PORT_MASK bit
shows only the value for the ring ports. For the other ports (ports 2-6), the VLAN_PORT_MASK bits are
assumed to be 0.
Table 233 • VLAN Table Configuration Before APS
Address (VID)
TUPE_CTRL
VLAN_PORT_MASK
VLAN_FID
4-9
0x01
0x0003
4-9
10-19
0x03
0x0083
10-19
31-32
0x01
0x0003
31-32
20-30, 40-50
0x02
0x0080
20-30, 40-50
VID 4-9 and 31-32 are only used by ring 1, so only bit 0 is set in TUPE_CTRL. VLAN_PORT_MASK
includes the two ring ports of ring 1, port 0, and port 1.
VID 10-19 are used by both ring 1 and ring 2, so bit 0 and bit 1 are both set in TUPE_CTRL.
VLAN_PORT_MASK includes the ring ports of ring 1 as well as port 7, used by ring 2. Port 8 is not
included, because it is in blocking state.
VID 20-30 and 40-50 are only used by ring 2, so only bit 1 is set in TUPE_CTRL. VLAN_PORT_MASK
includes port 7.
In this example, independently learning is used for all VLANs; that is, a separate FID is used for each
VID.
To also block reception of frames on any blocking ports, ANA_L3:COMMON:VLAN_FILTER_CTRL must
be configured to include all ring ports. In this example ports 0,1,7 and 8 must be set in
ANA_L3:COMMON:VLAN_FILTER_CTRL.
The following illustration shows the same set up as the previous illustration, but now a link in ring 2 has
failed. As a result, the RPL of ring 2 must be activated, meaning port 8 of switch A must be changed to
forwarding state.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
298
Functional Descriptions
Figure 89 • Ethernet Ring with Failure
Ethernet Switch A
0
1
2
3
4
5
6
7
8
Ring protection link (RPL)
Ring 1
VLANs: 4-19, 31-32
Ethernet
Switch
B
Ethernet
Switch
D
Ethernet
Switch
E
Ring protection link (RPL)
Ring 2
VLANs: 10-30, 40-50
Ethernet
Switch
G
Link failure!
Ethernet
Switch
C
Ethernet
Switch
F
RPL port
To avoid having to perform write access to the VLAN_PORT_MASKs of each of VID 10-30 and 40-50,
VLAN TUPE can be used instead. The following table lists the VLAN TUPE parameters to reconfigure
the VLAN table.
Table 234 • VLAN TUPE Command for Ring Protection Switching
Field
Value
Comment
TUPE_CTRL_BIT_MASK
0x0002
Bits 0 and 1 of TUPE_CTRL are used as bit mask.
The TUPE command is applied only to VIDs used by ring 2, so only
bit 1 is set.
TUPE_CTRL_BIT_ENA
1
Enables use of TUPE_CTRL_BIT_MASK.
TUPE_START_ADDR
10
To make VLAN TUPE complete faster, only cover VID 10-50.
TUPE_END_ADDR
50
TUPE_CMD_PORT_MASK_SET
0x0100
Enables forwarding on port 8.
TUPE_START
1
Starts VLAN TUPE. The device clears TUPE_START when TUPE
is completed.
After the VLAN TUPE command is completed, the VLAN table is updated as shown in the following table.
Table 235 • VLAN Table Configuration After APS
Addr (VID)
TUPE_CTRL
VLAN_PORT_MASK
VLAN_FID
4-9
0x01
0x0003
4-9
10-19
0x03
0x0183
10-19
31-32
0x01
0x0003
31-32
20-30, 40-50
0x02
0x0180
20-30, 40-50
The TUPE_CTRL field is 16 bits wide, so using the described approach allows up 16 Ethernet rings with
VLAN TUPE assisted protection switching. However, any unused bits in the 53-bit wide
VLAN_PORT_MASK can be used in the same manner as TUPE_CTRL bits. For example, a 24-port
switch only using bits 0-23 and 52-53 (CPU) in the VLAN_PORT_MASK have an additional 27 bits,
which can be used as an extension of the TUPE_CTRL field.
For Ethernet rings using only a few VIDs, there is little to gain in using VLAN TUPE and new values could
instead be written directly to the VLAN_PORT_MASK of the relevant VIDs.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
299
Functional Descriptions
In addition to running the VLAN TUPE commands listed in the previous table, any MAC addresses
learned on the ring ports of ring 2 must be flushed from the MAC table. In the above example, ring 2 uses
32 VIDs for forwarding traffic. Each of these use a specific FID. In this example, FID is set equal to VID.
MAC addresses for up to 16 FIDs can be flushed at a time, so to flush MAC addresses for 32 FIDs, two
flush commands must be executed. The first flush command is shown in the following table. The second
flush command is identical, except SCAN_FID_VAL is set to 26-30, 40-50.
Table 236 • MAC Table Flush, First Command
Field
Value
Comment
ANA_L2::SCAN_FID_CTRL.SCAN_FID_ENA
1
Enables use of SCAN_FID_VAL.
ANA_L2::SCAN_FID_CFG.SCAN_FID_VAL
10-25
Flushes FIDs 10-25.
Flushing can be done for up to 16 discrete FID
values at a time.
If flushing needs to be done for less than 16 FIDs.
the unused FID values must be set to 0x1FFFF.
LRN::SCAN_NEXT_CFG.FID_FILTER_ENA
1
Enables FID specific flushing.
LRN::MAC_ACCESS_CFG_0.MAC_ENTRY_FID
0x1FFFF 0x1FFFF => not used.
LRN::AUTOAGE_CFG_1.USE_PORT_FILTER_ENA 1
Enables flushing for specific ports.
ANA_L2::FILTER_LOCAL_CTRL
0x0180
Flushes port 7 and 8.
LRN::SCAN_NEXT_CFG.SCAN_NEXT_REMOVE_
FOUND_ENA
1
Removes matches. In other words flushing.
LRN::COMMON_ACCESS_CTRL.MAC_TABLE_
ACCESS_SHOT
1
Start flushing.
The device clears MAC_TABLE_ACCESS_SHOT
when flushing has completed.
If desirable the device can be configured to
generate an interrupt when flushing has completed.
This can be used to trigger any subsequent flush
commands.
Flushing MAC addresses from the MAC table usually takes longer than running VLAN TUPE. As a result,
to have the protection switching complete as fast as possible, start MAC table flushing first, followed by
VLAN TUPE. The two will then run in parallel, and when both have completed, the protection switching is
done.
3.32.2
Link Aggregation
For ring protection, the working/protection entity can be forwarded on a LAG, providing an additional
layer of hardware assisted protection switching.
When a link within the LAG fails, the 16 port masks in ANA_AC:AGGR must be updated to avoid
forwarding on the failed link.
To avoid consuming multiple entries in VCAP ES0 for services being forwarded on a LAG,
REW:COMMON:PORT_CTRL.ES0_LPORT_NUM must be setup such that a common port number is
used in VCAP ES0 keys, regardless of the actual LAG member chosen.
3.32.3
Port Protection Switching
The devices support several methods through which 1:1 port protection switching can be supported:
•
•
•
Link Aggregation Groups. A LAG with two ports can be configured and ANA_AC:AGGR can be set
to only use one of the links in the LAG.
Disabling the standby port in ANA_L3:MSTP.
Disabling the standby port using ANA_L3:COMMON:PORT_FWD_CTRL and
ANA_L3:COMMON:PORT_LRN_CTRL. This is the recommended approach, because it interferes
minimally with other features of the devices.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
300
Functional Descriptions
Regardless of the method, a logical port number must be configured for the involved ports such that MAC
addresses are learned on the logical port number to avoid the need for flushing MAC table entries when
protection switching occurs. The logical port number is configured in
ANA_CL:PORT:PORT_ID_CFG.LPORT_NUM.
REW:COMMON:PORT_CTRL.ES0_LPORT_NUM must be used to avoid consuming multiple VCAP
ES0 entries. For more information, see Link Aggregation, page 300.
3.33
High-Speed Mode
For applications that require more than 80 Gbps of Ethernet I/O bandwidth, it is possible to change the
switch core to a high-speed mode where the operating clock frequency is increased compared to the
normal clock frequency. Configuration of the switch core clock frequency is done after reset, before
enabling switch ports.
3.33.1
One-Time Configurations for High-Speed Mode
For applications that require more than 80 Gbps of bandwidth, use the following steps to reconfigure the
switch core clock frequency.
1.
2.
3.
4.
5.
3.34
Configure the switch core clock frequency:
HSIO:PLL5G_CFG:PLL5G_CFG0.CORE_CLK_DIV = 3 (write to both PLLs when applicable)
Configure VCore to operate with higher frequency:
DEVCPU_PTP::PTP_SYS_CLK_CFG.PTP_SYS_CLK_PER_NS = 3,
DEVCPU_PTP::PTP_SYS_CLK_CFG.PTP_SYS_CLK_PER_PS100 = 6,
DEVCPU_GCB::SIO_CLOCK.SYS_CLK_PERIOD = 36.
Configure analyzer to operate with higher frequency:
ANA_AC_POL::COMMON_SDLB.CLK_PERIOD_01NS = 36,
ANA_AC_POL::COMMON_BDLB.CLK_PERIOD_01NS = 36,
ANA_AC_POL::COMMON_BUM_SLB.CLK_PERIOD_01NS = 36,
LRN::AUTOAGE_CFG_1.CLK_PERIOD_01NS = 36,
ANA_AC_POL::POL_UPD_INT_CFG.POL_UPD_INT = 693.
Configure scheduler to operate with higher frequency:
HSCH::SYS_CLK_PER.SYS_CLK_PER_100PS = 36.
Configure AFI to operate with higher frequency:
AFI_TTL_TICKS:TTI_TICK_BASE.BASE_LEN = 14444.
Clocking and Reset
The devices have two PLLs: PLL and PLL2. By default, PLL2 is disabled, however, it can be enabled by
setting the REFCLK2_EN input pin.
When PLL2 is disabled, all clocks are provided by PLL. When PLL2 is enabled, it provides the clock for
the central part of the switch core, including the IEEE 1588 one-second timers. The PLL always provides
clocks for the SerDes and for the VCore-III CPU system. By enabling PLL2, the IEEE 1588 clock can, in
particular, be made independent of a clock recovered by synchronous Ethernet clock.
The PLL2 can be used as a recovered clock source for Synchronous Ethernet. For information about
how to configure PLL2 clock recovery, see Layer 1 Timing, page 276.
The reference clocks for PLL and PLL2 (REFCLK_P/N and REFCLK2_P/N) are either differential or
single-ended. The frequency can be 25 MHz (REFCLK2 only), 125 MHz, 156.25 MHz, or 250 MHz. PLL
and PLL2 must be configured for the appropriate clock frequency by using strapping inputs
REFCLK_CONF[2:0] and REFCLK2_CONF[2:0].
PLL and PLL2 can be used as a recovered clock sources for Synchronous Ethernet. For information
about how to configure PLL and PLL2 clock recovery, see Layer 1 Timing, page 276.
For information about protecting the VCore CPU system during a soft-reset, see Clocking and Reset,
page 307.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
301
Functional Descriptions
3.34.1
Pin Strapping
Configure PLL2 reference clocks and VCore startup mode using the strapping pins on the GPIO
interface. The device latches strapping pins and keeps their value when nRESET to the device is
released. After reset is released, the strapping pins are used for other functions. For more information
about which GPIO pins are used for strapping, see GPIO Overlaid Functions, page 354.
By using resistors to pull the GPIOs either low or high, software can use these GPIO pins for other
functions after reset has been released.
Undefined configurations are reserved and cannot be used. VCore-III configurations that enable a front
port or the PCIe endpoint drive VCore_CFG[3:2] high when the front port or PCIe endpoint is ready to
use.
Table 237 • Pin Strapping
Pin
Description
REFCLK2_SEL
Strap high to enable PLL2.
0: PLL is source of switch core and VCore clocks. PLL2 is powered down, but can be
enabled through registers.
1: PLL2 is source of switch core and VCore clocks.
REFCLK_CONF[2:0]
Reference clock frequency for PLL.
REFCLK2_CONF[2:0] Configuration of reference clock frequency for PLL2, this is don't care if PLL2 is not enabled.
000: 125 MHz
001: 156.25 MHz
010: 250 MHz
100: 25 MHz
Other values are reserved and must not be used.
VCORE_CFG[3:0]
0000
VCore-III CPU is enabled (Little Endian mode) and boots from SI (the SI slave is disabled).
0001
PCIe 1.x endpoint is enabled. Port 10 is enabled for SFI 10G, and NPI port 4 is enabled for
SERDES NoAneg 1G FDX NoFC. VRAP block is accessible through the NPI port. Automatic
boot of VCore-III CPU is disabled, and SI slave is enabled.
0010
PCIe 1.x endpoint is enabled. Port 6 is enabled for SERDES NoAneg 1G FDX NoFC, and
NPI port 4 is enabled for SERDES NoAneg 1G FDX NoFC. VRAP block is accessible
through the NPI port. Au-tomatic boot of VCore-III CPU is disabled, and SI slave is enabled.
0011
PCIe 1.x endpoint is enabled. Port 0 is enabled for SERDES NoAneg 1G FDX NoFC, and
NPI port 4 is enabled for SERDES NoAneg 1G FDX NoFC. VRAP block is accessible
through the NPI port. Au-tomatic boot of VCore-III CPU is disabled, and SI slave is enabled.
0100
PCIe 1.x endpoint is enabled. Port 10 is enabled for SFI 10G, and NPI port 9 is enabled for
SFI 10G. VRAP block is accessible through the NPI port. Automatic boot of VCore-III CPU is
disabled, and SI slave is enabled.
0101
PCIe 1.x endpoint is enabled. NPI port 9 is enabled for SFI 10G. VRAP block is accessible
through the NPI port. Automatic boot of VCore-III CPU is disabled, and SI slave is enabled.
1000
PCIe 1.x endpoint is enabled. NPI port 4 is enabled for SERDES NoAneg 1G FDX NoFC.
VRAP block is accessible through the NPI port. Automatic boot of VCore-III CPU is disabled,
and SI slave is enabled.
1001
PCIe 1.x endpoint is enabled. Automatic boot of VCore-III CPU is disabled, and SI slave is
enabled.
1010
MIIM slave is enabled with MIIM address 0 (MIIM slave pins are overlaid on GPIOs).
Automatic boot of VCore-III CPU is disabled, and SI slave is enabled.
1011
MIIM slave is enabled with MIIM address 31 (MIIM slave pins are overlaid on GPIOs).
Automatic boot of VCore-III CPU is disabled, and SI slave is enabled.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
302
Functional Descriptions
Table 237 • Pin Strapping (continued)
Pin
Description
1100
VCore-III CPU is enabled (Big Endian mode) and boots from SI (the SI slave is disabled).
1111
Automatic boot of VCore-III CPU is disabled, and SI slave is enabled.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
303
Registers
4
Registers
Information about the registers for this product is available in the attached Adobe Acrobat file. To view or
print the information, double-click the attachment icon.
The registers are common to the VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 devices.
Registers not applicable to a specific device are marked accordingly.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
304
VCore-III System and CPU Interfaces
5
VCore-III System and CPU Interfaces
This section provides information about the functional aspects of blocks and interfaces related to the
VCore-III on-chip microprocessor system and an external CPU system.
The VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 devices contain a powerful VCore-III
CPU system that is based on an embedded MIPS24KEc-compatible microprocessor and a high
bandwidth Ethernet Frame DMA engine. The VCore-III system can control the devices independently, or
it can support an external CPU, relieving the external CPU of the otherwise time consuming tasks of
transferring frames, maintaining the switch core, and handling networking protocols.
When the VCore-III CPU is enabled, it either automatically boots up from serial Flash or a external CPU
can manually load a code-image to the devices and then start the VCore-III CPU.
An external CPU can be connected to the VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02
devices through the PCIe interface, serial interface (SI), dedicated MIIM slave interface, or through
Versatile Register Access Protocol (VRAP) formatted Ethernet frames using the NPI Ethernet port.
Through these interfaces, the external CPU has access to the complete set of device registers and can
control them without help from the VCore-III CPU if needed.
The following illustration shows the VCore-III block diagram.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
305
VCore-III System and CPU Interfaces
Figure 90 • VCore-III System Block Diagram
VRAP
(Register access
through Ethernet)
SI Slave(1)
GPIO I/O
Controller
Switch Core
Register Bus
Access/Arbiter
MIIM Slave
VCore CPU
SGPIO I/O
Controller
MIIM
Masters × 3
Fan
Controller
Switch Core Register Bus (CSR)
VCore SBA
Access Block
Temperature
Sensor
Switch Core
Registers
Switch Core
Access Block
Interrupt
Controller
Timers × 3
VCore Shared Bus
Access/Arbiter
SI Flash Boot
Master(1)
VCore Shared Bus (SBA)
PCIe Inbound(2)
Two-Wire Serial
Interface × 2
Manual Frame
Inject/Extract
UART × 2
Frame DMA
(FDMA)
PCIe
Outbound
DDR3/3L
Controller
1. When the Vcore-III CPU boots up from the SI Flash, the SI is reserved as boot interface and cannot be used by an external CPU.
2. Inbound PCIe access to BAR0 maps to VCore register space (switch core access block, interrupt controller, timers, two -wire serial
master/slave, UARTs, and manual frame injection/extraction). Inbound PCIe access to BAR2 maps to the DDR3/3L memory space
(DDR controller).
5.1
VCore-III Configurations
The behavior of the VCore-III system after a reset is determined by four VCore strapping pins that are
overlaid on GPIO pins. The value of these GPIOs is sampled shortly after releasing reset to the devices.
For more information about the strapping pins, see Pin Strapping, page 302.
The strapping value determines the reset value for the ICPU_CFG::GENERAL_CTRL register. After
startup, the behavior of the VCore-III system can be modified by changing some of the fields in this
register. The following are common scenarios.
•
•
After starting the devices with the VCore-III CPU disabled, an external CPU can manually boot the
VCore-III CPU from SI Flash by writing ICPU_CFG::GENERAL_CTRL.IF_SI_MST_ENA = 1,
ICPU_CFG::GENERAL_CTRL.BOOT_MODE_ENA = 1, and
ICPU_CFG::GENERAL_CTRL.CPU_DIS = 0. Endianess is configured by
ICPU_CFG::GENERAL_CTRL.CPU_BE_ENA. Setting GENERAL_CTRL.IF_SI_MST_ENA
disables the SI slave, so the external CPU must use another interface than SI.
After starting the devices with the VCore-III CPU disabled and loading software into DDR3/DDR3L
memory, an external CPU can boot the VCore-III CPU from DDR3/DDR3L memory by writing
ICPU_CFG::GENERAL_CTRL.BOOT_MODE_ENA = 0 and
ICPU_CFG::GENERAL_CTRL.CPU_DIS = 0. Endianess is configured using
ICPU_CFG::GENERAL_CTRL.CPU_BE_ENA.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
306
VCore-III System and CPU Interfaces
•
•
After automatically booting from SI Flash, the VCore-III CPU can release the SI interface and enable
the SI slave by writing ICPU_CFG::GENERAL_CTRL.IF_SI_MST_ENA = 0. This enables SI access
from an external CPU to the devices. A special PCB design is required to make the serial interface
work for both Flash and external CPU access.
MIIM slave can be manually enabled by writing
ICPU_CFG::GENERAL_CTRL.IF_MIIM_SLV_ENA = 1. The MIIM slave automatically takes control
of the appropriate GPIO pins.
The EJTAG interface of the VCore-III CPU and the Boundary Scan JTAG controller are both multiplexed
onto the JTAG interface of devices. When the JTAG_ICE_nEN pin is low, the MIPS’s EJTAG controller is
selected. When the JTAG_ICE_nEN pin is high, the Boundary Scan JTAG controller is selected.
5.2
Clocking and Reset
The following table lists the registers associated with reset and the watchdog timer.
Table 238 • Clocking and Reset Configuration Registers
Register
Description
ICPU_CFG::RESET
VCore-III reset protection scheme and initiating soft reset of
the VCore-III System and/or CPU.
DEVCPU_GCB::SOFT_RST
Initiating chip-level soft reset.
ICPU_CFG::WDT
Watchdog timer configuration and status.
The VCore-III CPU runs 500 MHz, the DDR3/DDR3L controller runs 312.50 MHz, and the rest of the
VCore-III system runs at 250 MHz.
The VCore-III can be soft reset by setting RESET.CORE_RST_FORCE. By default, this resets both the
VCore-III CPU and the VCore-III system. The VCore-III system can be excluded from a soft reset by
setting RESET.CORE_RST_CPU_ONLY; soft reset using CORE_RST_FORCE only then resets the
VCore-III CPU. The frame DMA must be disabled prior to a soft reset of the VCore-III system. When
CORE_RST_CPU_ONLY is set, the frame DMA, PCIe endpoint, and DDR3/DDR3L controller are not
affected by a soft reset and continue to operate throughout soft reset of the VCore-III CPU.
The VCore-III system comprises all the blocks attached to the VCore Shared Bus (SBA), including the
PCIe, DDR3/DDR3L, and frame DMA/injection/extraction blocks. Blocks attached to the switch core
Register Bus (CSR), including VRAP, SI, and MIIM slaves, are not part of the VCore-III system reset
domain. For more information about the VCore-III system blocks, see Figure 90, page 306.
The devices can be soft reset by writing SOFT_RST.SOFT_CHIP_RST. The VCore-III system and CPU
can be protected from a device soft reset by writing RESET.CORE_RST_PROTECT = 1 before initiating
a soft reset. In this case, a chip-level soft reset is applied to all other blocks, except the VCore-III system
and the CPU. When protecting the VCore-III system and CPU from a soft reset, the frame DMA must be
disabled prior to a chip-level soft reset. The SERDES and PLL blocks can be protected from reset by
writing to SOFT_RST.SOFT_SWC_RST instead of SOFT_CHIP_RST.
The VCore-III general purpose registers (ICPU_CFG::GPR) and GPIO alternate modes
(DEVCPU_GCB::GPIO_ALT) are not affected by a soft reset. These registers are only reset when an
external reset is asserted.
5.2.1
Watchdog Timer
The VCore system has a built-in watchdog timer (WDT) with a two-second timeout cycle. The watchdog
timer is enabled, disabled, or reset through the WDT register. The watchdog timer is disabled by default.
After the watchdog timer is enabled, it must be regularly reset by software. Otherwise, it times out and
cause a VCore soft reset equivalent to setting RESET.CORE_RST_FORCE. Improper use of the
WDT.WDT_LOCK causes an immediate timeout-reset as if the watchdog timer had timed out. The
WDT.WDT_STATUS field shows if the last VCore-III CPU reset was caused by WDT timeout or regular
reset (possibly soft reset). The WDT.WDT_STATUS field is updated only during VCore-III CPU reset.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
307
VCore-III System and CPU Interfaces
To enable or to reset the watchdog timer, write the locking sequence, as described in WDT.WDT_LOCK,
at the same time as setting the WDT.WDT_ENABLE field.
Because watchdog timeout is equivalent to setting RESET.CORE_RST_FORCE, the
RESET.CORE_RST_CPU_ONLY field also applies to watchdog initiated soft reset.
5.3
Shared Bus
The shared bus is a 32-bit address and 32-bit data bus with dedicated master and slave interfaces that
interconnect all the blocks in the VCore-III system. The VCore-III CPU, PCIe inbound, and VCore SBA
access block are masters on the shared bus; only they can start access on the bus.
The shared bus uses byte addresses, and transfers of 8, 16, or 32 bits can be made. To increase
performance, bursting of multiple 32-bit words on the shared bus can be performed.
All slaves are mapped into the VCore-III system’s 32-bit address space and can be accessed directly by
masters on the shared bus. Two possible mappings of VCore-III shared bus slaves are boot mode and
normal mode.
•
•
Boot mode is active after power-up and reset of the VCore-III system. In this mode, the SI Flash boot
master is mirrored into the lowest address region.
In normal mode, the DDR3/DDR3L controller is mirrored into the lowest address region.
Changing between boot mode and normal mode is done by first writing and then reading
ICPU_CFG::GENERAL_CTRL.BOOT_MODE_ENA. A change takes effect during the read.
The devices supports up to 1 gigabyte (GB) of DDR3/DDR3L memory. By default, only 512 megabytes
(MB) is accessible in the memory map. To accommodate more than 512 MB of memory, write
ICPU_CFG::MEMCTRL_CFG.DDR_512MBYTE_PLUS = 1.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
308
VCore-III System and CPU Interfaces
Figure 91 • Shared Bus Memory Map
0x00000000
0x10000000
0x20000000
0x40000000
0x50000000
0x70000000
0x80000000
Boot Mode (Physical), 512 MB
256 MB Mirror of SI Flash
256 MB
512 MB
256 MB
512 MB
256 MB
Reserved
0x00000000
0x20000000
DDR3/DDR3L
SI Flash
0x40000000
0x50000000
Reserved
Chip Registers
1 GB
0x70000000
0x80000000
Normal Mode (Physical), 512 MB
512 MB
Mirror of DDR3/DDR3L
512 MB
256 MB
512 MB
256 MB
0x00000000
0x10000000
PCIe DMA
0xFFFFFFFF
Boot Mode (Physical), 1 GB(1)
256 MB Mirror of SI Flash
0x00000000
Normal Mode (Physical), 1 GB(1)
1 GB
768 MB
Mirror of DDR3/DDR3L
Reserved
0x40000000
0x50000000
0x70000000
0x80000000
256 MB
512 MB
256 MB
SI Flash
0x40000000
0x50000000
Reserved
Chip Registers
1 GB
0x70000000
0x80000000
256 MB
512 MB
256 MB
PCIe DMA
0xFFFFFFFF
Reserved
Chip Registers
DDR3/DDR3L
0xC0000000
1 GB
SI Flash
1 GB
DDR3/DDR3L
0xC0000000
Chip Registers
1 GB
PCIe DMA
0xFFFFFFFF
Reserved
Reserved
0xC0000000
1 GB
SI Flash
1 GB
Reserved
0xC0000000
DDR3/DDR3L
1 GB
PCIe DMA
0xFFFFFFFF
1. To enable support 1 gigabyte (GB) of DDR3/DDR3L memory (and the associated
memory map), set ICPU_CFG::MEMCTRL_CFG.DDR_512MBYTE_PLUS.
Note: When the VCore-III system is protected from a soft reset using
ICPU_CFG::RESET.CORE_RST_CPU_ONLY, a soft reset does not change shared bus memory
mapping. For more information about protecting the VCore-III system when using a soft reset, see
Clocking and Reset, page 307.
If the boot process copies the SI Flash image to DDR3/DDR3L, and if the contents of the SI memory and
the DDR3 memory are the same, software can execute from the mirrored region when swapping from
boot mode to normal mode. Otherwise, software must be execute from the fixed SI Flash region when
changing from boot mode to normal mode.
The Frame DMA has dedicated access to PCIe outbound and to the DDR3/DDR3L. This means that
access on the SBA to other parts of the devices, such as register access, does not affect Frame DMA
injection/extraction performance.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
309
VCore-III System and CPU Interfaces
5.3.1
VCore-III Shared Bus Arbitration
The following table lists the registers associated with the shared bus arbitration.
Table 239 • Shared Bus Configuration Registers
Register
Description
SBA::PL_CPU
Master priorities
SBA::PL_PCIE
Master priorities
SBA::PL_CSR
Master priorities
SBA::WT_EN
Enable of weighted token scheme
SBA::WT_TCL
Weighted token refresh period
SBA::WT_CPU
Token weights for weighted token scheme
SBA::WT_PCIE
Token weights for weighted token scheme
SBA::WT_CSR
Token weights for weighted token scheme
The VCore-III shared bus arbitrates between masters that want to access the bus. The default is to use a
strict prioritized arbitration scheme where the VCore-III CPU has highest priority. The strict priorities can
be changed using registers PL_CPU, PL_PCIE, and PL_CSR.
•
•
•
*_CPU registers apply to VCore-III CPU access
*_PCIE registers apply to inbound PCIe access
*_CSR registers apply to VCore-III SBA access block access
It is possible to enable weighted token arbitration scheme (WT_EN). When using this scheme, specific
masters can be guaranteed a certain amount of bandwidth on the shared bus. Guaranteed bandwidth
that is not used is given to other masters requesting the shared bus.
When weighted token arbitration is enabled, the masters on the shared bus are grated a configurable
number of tokens (WT_CPU, WT_PCIE, and WT_CSR) at the start of each refresh period. The length of
each refresh period is configurable (WT_TCL). For each clock cycle that the master uses the shared bus,
the token counter for that master is decremented. When all tokens are spent, the master is forced to a
low priority. Masters with tokens always take priority over masters with no tokens. The strict prioritized
scheme is used to arbitrate between masters with tokens and between masters without tokens.
Example Guarantee That PCIe Can Get 25% Bandwidth. Configure WT_TCL to a refresh period of
2048 clock cycles; the optimal length of the refresh period depends on the scenario, experiment to find
the right setting. Guarantee PCIe access in 25% of the refresh period by setting WT_PCIE to 512 (2048
× 25%). Set WT_CPU and WT_CSR to 0. This gives the VCore-III CPU and CSR unlimited tokens.
Configure PCIe to highest priority by setting PL_PCIe to 15. Finally, enable the weighted token scheme
by setting WT_EN to 1. For each refresh period of 2048 clock cycles, PCIe is guaranteed access to the
shared bus for 512 clock cycles, because it is the highest priority master. When all the tokens are spend,
it is put into the low-priority category.
5.3.2
Chip Register Region
Registers in the VCore-III domain and inside the switch core are memory mapped into the chip registers
region of the shared bus memory map. All registers are 32-bit wide and must only be accessed using 32bit reads and writes. Bursts are supported.
Writes to this region are buffered (there is a one-word write buffer). Multiple back-to-back write access
pauses the shared bus until the write buffer is freed up (until the previous writes are done). Reads from
this region pause the shared bus until read data is available.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
310
VCore-III System and CPU Interfaces
Figure 92 • Chip Registers Memory Map
0x70000000
1 MB
VCore Registers
0x70100000
0x70100400
0x70100800
0x70100C00
0x70101000
0x70101400
0x70110000
0x70110400
0x70111000
0x70112000
0x71000000
1 KB
UART Registers
1 KB
TWI Registers
1 KB
UART2 Registers
1 KB
TWI2 Registers
1 KB
SIMC Registers
59 KB
1 KB
3 KB
1 KB
15 MB
Reserved
SBA Registers
Reserved
PCIe Registers
Reserved
16 MB
Switch Core Registers
0x72000000
The registers in the 0x70000000 through 0x70FFFFFF region are physically located inside the VCore-III
system, so read and write access to these registers is fast (done in a few clock cycles). All registers in
this region are considered fast registers.
Registers in the 0x71000000 through 0x71FFFFFF region are located inside the switch core; access to
registers in this range takes approximately 1 µs. The DEVCPU_ORG and DEVCPU_QS targets are
special; registers inside these two targets are faster; access to these two targets takes approximately
0.1 µs.
When more than one CPU is accessing registers, the access time may be increased. For more
information, see Register Access and Multimaster Systems.
Writes to the Chip Registers region is buffered (there is a one-word write buffer). Multiple back-to-back
write access pauses the shared bus until the write buffer is freed up (until the previous write is done). A
read access pause the shared bus until read data is available. Executing a write immediately followed by
a read requires the write to be done before the read can be started.
5.3.3
SI Flash Region
Read access from the SI Flash region initiates Flash formatted read access on the SI pins of the devices
by means of the SI boot controller.
The SI Flash region cannot be written to. Writing to the SI interface must be implemented by using the SI
master controller. For more information, see SI Master Controller, page 336. For legacy reasons, it is also
possible to write to the SI interface by using the SI boot master’s software “bit-banging” register interface.
For more information, see SI Boot Controller, page 334.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
311
VCore-III System and CPU Interfaces
5.3.4
DDR3/DDR3L Region
Read and write access from or to the DDR3/DDR3L region maps to access on the DDR3 interface of the
devices using the DDR3 controller. For more information about the DDR3/DDR3L controller and
initializing DDR3/DDR3L memory, see DDR3/DDR3L Memory Controller.
5.3.5
PCIe Region
Read and write access from or to the PCIe region maps to outbound read and write access on the PCIe
interface of the devices by means of the PCIe endpoint controller. For more information about the PCIe
endpoint controller and how to reach addresses in 32-bit and 64-bit PCIe environments, see PCIe
Endpoint Controller.
5.4
VCore-III CPU
The VCore-III CPU system is based on a powerful MIPS24KEc-compatible microprocessor with 16-entry
MMU, 32 kilobytes (kB) instruction, and 32 kB data caches.
This section describes how the VCore-III CPU is integrated into the VCore-III system. For more
information about internal VCore-III CPU functions, such as bringing up caches, MMU, and so on, see
the software board support package (BSP) at www.microsemi.com.
When the automatic boot in the little-endian or big-endian mode is enabled using the VCore-III strapping
pins, the VCore-III CPU automatically starts to execute code from the SI Flash at byte address 0.
The following is a typical automatic boot sequence.
1.
2.
3.
4.
Speed up the boot interface. For more information, see SI boot controller.
Initialize the DDR3/DDR3L controller. For more information, see DDR3/DDR3L Memory Controller
Copy code-image from Flash to DDR3/DDR3L memory.
Change memory map from boot mode to normal mode, see Shared Bus.
When automatic boot is disabled, an external CPU is still able to start the VCore-III CPU through
registers. For more information, see VCore Configurations.
The boot vector of the VCore-III CPU is mapped to the start of the KESEG1, which translates to physical
address 0x00000000 on the VCore-III shared bus.
The VCore-III CPU interrupts are mapped to interrupt inputs 0 and 1, respectively.
5.4.1
Little Endian and Big Endian Support
The VCore-III system is constructed as a little endian system, and registers descriptions reflect little
endian encoding. When big endian mode is enabled, instructions and data are byte-lane swapped just
before they enter and when they leave the VCore-III CPU. This is the standard way of translating
between a CPU in big endian mode and a little endian system.
In big endian mode, care must be taken when accessing parts of the memory system that is also used by
users other than the VCore-III CPU. For example, VSC7442-02, VSC7444-02, VSC7448-02, and
VSC7449-02 device registers are written and read by the VCore-III CPU, but they are also used by the
devices (which sees them in little endian mode). The VCore-III BSP contains examples of code that
correctly handles register access for both little and big endian mode.
Endianess of the CPU is selected by VCore-III strapping pins or by register configuration when manually
booting the CPU. For more information, see VCore-III configurations.
5.4.2
Software Debug and Development
The VCore CPU has a standard MIPS EJTAG debug interface that can be used for breakpoints, loading
of code, and examining memory. When the JTAG_ICE_nEN strapping pin is pulled low, the JTAG
interface is attached to the EJTAG controller.
5.5
External CPU Support
An external CPU attaches to the VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 devices
through the PCIe, SI, MIIM, or VRAP. Through these interfaces, an external CPU can access (and
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
312
VCore-III System and CPU Interfaces
control) the devices. For more information about interfaces and connections to device registers, see
VCore-III system block diagram.
Inbound PCIe access is performed on the VCore Shared Bus (SBA) in the same way as ordinary VCoreIII CPU access. By means of the switch core Access block it is possible to access the Switch Core
Register (CSR) bus. For more information about supported PCIe BAR regions, see PCIe Endpoint
Controller.
The SI, MIIM, and VRAP interfaces attach directly to the CSR. Through the VCore SBA access block, it is
possible to access the VCore shared bus. For more information, see Access to the VCore Shared Bus.
The external CPU can coexist with the internal VCore-III CPU, and hardware-semaphores and interrupts
are implemented for inter-CPU communication. For more information, see Mailbox and Semaphores.
5.5.1
Register Access and Multimaster Systems
There are three different groups of registers in the devices:
•
•
•
Switch Core
Fast Switch Core
VCore
The Switch Core registers and Fast Switch Core registers are separated into individual register targets
and attached to the Switch Core Register bus (CSR). The Fast Switch Core registers are placed in the
DEVCPU_QS and DEVCPU_ORG register targets. Access to Fast Switch Core registers is less than
0.1 µs; other Switch Core registers take no more than 1 µs to access.
The VCore registers are attached directly to the VCore shared bus. The access time to VCore registers is
negligible (a few clock cycles).
Although multiple masters can access VCore registers and Switch Core registers in parallel without
noticeable penalty to the access time, the following exceptions apply.
•
•
•
When accessing the same Switch Core register target (for example, DEVCPU_GCB), the second
master to attempt access has to wait for the first master to finish (round robin arbitration applies.)
This does not apply to Fast Switch Core register targets (DEVCPU_QS and DEVCPU_ORG).
If both the VCore-III CPU and the PCIe master are performing Switch Core Register bus (CSR)
access, both need to be routed through the Switch Core Access block. The second master has to
wait for the first master to finish (shared bus arbitration applies).
If two or more SI, MIIM, or VRAP masters are performing VCore register access, they all need to go
through the VCore SBA Access block. Ownership has to be resolved by use of software (for
example, by using the build-in semaphores).
The most common multimaster scenario is with an active VCore-III CPU and an external CPU using
either SI or VRAP. In this case, Switch Core register access to targets that are used by both CPUs may
see two times the access time (no more than 2 µs).
5.5.2
Serial Interface in Slave Mode
This section provides information about the function of the serial interface in slave mode.
The following table lists the registers associated with SI slave mode.
Table 240 • SI Slave Mode Register
Register
Description
DEVCPU_ORG::IF_CTRL
Configuration of endianess and bit order
DEVCPU_ORG::IF_CFGSTAT
Configuration of padding
ICPU_CFG::GENERAL_CTRL
SI interface ownership
The serial interface implements a SPI-compatible protocol that allows an external CPU to perform read
and write access to register targets within the VSC7442-02, VSC7444-02, VSC7448-02, and
VSC7449-02 devices. Endianess and bit order is configurable, and several options for high frequencies
are supported.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
313
VCore-III System and CPU Interfaces
The serial interface is available to an external CPU when the VCore-III CPU does not use the SI for Flash
or external SI access. For more information, VCore-III System and CPU interfaces.
The following table lists the serial interface pins when the SI slave is configured as owner of SI interface
in GENERAL_CTRL.IF_SI_OWNER.
Table 241 • SI Slave Mode Pins
Pin Name
I/O
Description
SI_nCS0
I
Active-low chip select
SI_CLK
I
Clock input
SI_DI
I
Data input (MOSI)
SI_DO
O
Data output (MISO)
SI_DI is sampled on rising edge of SI_CLK. SI_DO is driven on falling edge of SI_CLK. There are no
requirements on the logical values of the SI_CLK and SI_DI inputs when SI_nCS is deasserted; they can
be either 0 or 1. SI_DO is only driven during read access when read data is shifted out of the devices.
The external CPU initiates access by asserting chip select and then transmitting one bit read/write
indication, one don’t care bit, 22 address bits, and 32 bits of write data (or don’t care bits when reading).
With the register address of a specific register (REG_ADDR), the SI address (SI_ADDR) is calculated as:
SI_ADDR = (REG_ADDR & 0x00FFFFFF)>>2
Data word endianess is configured through IF_CTRL[0]. The order of the data bits is configured using
IF_CTRL[1].
The following illustration shows various configurations for write access. The order of the data bits during
writing, as depicted, is also used when the devices are transmitting data during read operations.
Figure 93 • Write Sequence for SI
SI_nCS0
SI_CLK
Big endian mode (IF_CTRL[0]=1), Most significant bit first (IF_CTRL[1]=0)
SI_DI
2 2 1 1 1 1 1 1 1 1 1 1
3 3 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1
9 8 7 6 5 4 3 2 1 0
9 8 7 6 5 4 3 2 1 0
1 0 9 8 7 6 5 4 3 2 1 0
1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0
Serial Address (SI_ADDR)
Serial Data
SI_DO
Big endian mode (IF_CTRL[0]=1), Least significant bit first (IF_CTRL[1]=1)
SI_DI
2 2 1 1 1 1 1 1 1 1 1 1
2 2 2 2 2 2 3 3 1 1 1 1 2 2 2 2
1 1 1 1 1 1
9 8 7 6 5 4 3 2 1 0
8 9
0 1 2 3 4 5 6 7
1 0 9 8 7 6 5 4 3 2 1 0
4 5 6 7 8 9 0 1 6 7 8 9 0 1 2 3
0 1 2 3 4 5
Serial Address (SI_ADDR)
Serial Data
Little endian mode (IF_CTRL[0]=0), Most significant bit first (IF_CTRL[1]=0)
SI_DI
2 2 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1
2 2 2 2 1 1 1 1 3 3 2 2 2 2 2 2
9 8 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
9 8
1 0 9 8 7 6 5 4 3 2 1 0
5 4 3 2 1 0
3 2 1 0 9 8 7 6 1 0 9 8 7 6 5 4
Serial Address (SI_ADDR)
Serial Data
Little endian mode (IF_CTRL[0]=0), Least significant bit first (IF_CTRL[1]=1)
SI_DI
2 2 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 3 3
9 8 7 6 5 4 3 2 1 0 0 1 2 3 4 5 6 7 8 9
1 0 9 8 7 6 5 4 3 2 1 0
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
Serial Address (SI_ADDR)
Serial Data
When using the serial interface to read registers, the devices need to prepare read data after receiving
the last address bit. The access time of the register that is read must be satisfied before shifting out the
first bit of read data. For information about access time, see Register Access and Multimaster Systems.
The external CPU must apply one of the following solutions to satisfy read access time.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
314
VCore-III System and CPU Interfaces
•
•
•
Use SI_CLK with a period of minimum twice the access time for the register target. For example, for
normal switch core targets (single master):
1/(2 × 1 µs) = 500 kHz (maximum)
Pause the SI_CLK between shifting of serial address bit 0 and the first data bit with enough time to
satisfy the access time for the register target.
Configure the devices to send out padding bytes before transmitting the read data to satisfy the
access time for the register target. For example, 1 dummy byte allows enough read time for the SI
clock to run up to 6 MHz in a single master system. See the following calculation.
The devices are configured for inserting padding bytes by writing to IF_CFGSTAT.IF_CFG. These bytes
are transmitted before the read data. The maximum frequency of the SI clock is calculated as:
(IF_CFGSTAT.IF_CFG × 8 – 1.5)/access-time
For example, for normal switch core targets (single master), 1-byte padding give(1 × 8 – 1.5)
/1 µs = 6 MHz (maximum). The SI_DO output is kept tristated until the actual read data is transmitted.
The following illustrations show options for serial read access. The illustrations show only one mapping
of read data, little endian with most significant bit first. Any of the mappings can be configured and
applied to read data in the same way as for write data.
Figure 94 • Read Sequence for SI_CLK Slow
SI_nCS0
SI_CLK
Big endian mode (IF_CTRL[0]=1), Most significant bit first (IF_CTRL[1]=0), no padding (IF_CFGSTAT.IF_CFG=0)
SI_DI
2 2 1 1 1 1 1 1 1 1 1 1
9 8 7 6 5 4 3 2 1 0
1 0 9 8 7 6 5 4 3 2 1 0
Serial Address (SI_ADDR)
3 3 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1
9 8 7 6 5 4 3 2 1 0
1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0
SI_DO
Serial Data
Figure 95 • Read Sequence for SI_CLK Pause
SI_nCS0
pause
SI_CLK
Big endian mode (IF_CTRL[0]=1), Most significant bit first (IF_CTRL[1]=0), no padding (IF_CFGSTAT.IF_CFG=0)
SI_DI
2 2 1 1 1 1 1 1 1 1 1 1
9 8 7 6 5 4 3 2 1 0
1 0 9 8 7 6 5 4 3 2 1 0
Serial Address (SI_ADDR)
3 3 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1
9 8 7 6 5 4 3 2 1 0
1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0
SI_DO
Serial Data
Figure 96 • Read Sequence for One-Byte Padding
SI_nCS0
SI_CLK
Big endian mode (IF_CTRL[0]=1), Most significant bit first (IF_CTRL[1]=0), one-byte padding (IF_CFGSTAT.IF_CFG=1)
SI_DI
2 2 1 1 1 1 1 1 1 1 1 1
9 8 7 6 5 4 3 2 1 0
1 0 9 8 7 6 5 4 3 2 1 0
Serial Address (SI_ADDR)
3 3 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1
9 8 7 6 5 4 3 2 1 0
1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0
SI_DO
padding (1 byte)
Serial Data
When dummy bytes are enabled (IF_CFGSTAT.IF_CFG), the SI slave logic enables an error check that
sends out 0x88888888 and sets IF_CFGSTAT.IF_STAT if the SI master does not provide enough time for
register read.
When using SI, the external CPU must configure the IF_CTRL register after power-up, reset, or chiplevel soft reset. The IF_CTRL register is constructed so that it can be written no matter the state of the
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
315
VCore-III System and CPU Interfaces
interface. For more information about constructing write data for this register, see the instructions in
IF_CTRL.IF_CTRL.
5.5.3
MIIM Interface in Slave Mode
This section provides the functional aspects of the MIIM slave interface.
The MIIM slave interface allows an external CPU to perform read and write access to the device register
targets. Register access is done indirectly, because the address and data fields of the MIIM protocol is
less than those used by the register targets. Transfers on the MIIM interface are using the Management
Frame Format protocol specified in IEEE 802.3, Clause 22.
The MIIM slave pins on the devices are overlaid functions on the GPIO interface. MIIM slave mode is
enabled by configuring the appropriate VCore_CFG strapping pins. For more information, see VCore-III
Configurations, page 306. When MIIM slave mode is enabled, the appropriate GPIO pins are
automatically overtaken. For more information about overlaid functions on the GPIOs for these signals,
see GPIO Overlaid Functions, page 354.
The following table lists the pins of the MIIM slave interface.
Table 242 • MIIM Slave Pins
Pin Name
I/O
Description
MIIM_SLV_MDC/GPIO
I
MIIM slave clock input
MIIM_SLV_MDIO/GPIO
I/O
MIIM slave data input/output
MIIM_SLV_ADDR/GPIO
I
MIIM slave address select
MIIM_SLV_MDIO is sampled or changed on the rising edge of MIIM_SLV_MDC by the MIIM slave
interface.
The MIIM slave can be configured to answer on one of two different PHY addresses using the
MIIM_SLV_ADDR pin. Setting the MIIM_SLV_ADDR pin to 0 configures the MIIM slave to use PHY
address 0, and setting it to 1 configures the MIIM slave to use PHY address 31.
The MIIM slave has seven 16-bit MIIM registers defined as listed in the following table.
Table 243 • MIIM Registers
Register Address
Register Name
Description
0
ADDR_REG0
Bits 15:0 of the address to read or write. The address field must be
formatted as word address.
1
ADDR_REG1
Bits 31:16 of the address to read or write.
2
DATA_REG0
Bits 15:0 of the data to read or write. Returns 0x8888 if a register read
error occurred.
3
DATA_REG1
Bits 31:16 of the data to read or write. The read or write operation is
initiated after this register is read or written. Returns 0x8888 if read while
busy or a register read error occurred.
4
DATA_REG1_INCR
Bits 31:16 of data to read or write. The read or write operation is initiated
after this register is read or written. When the operation is complete, the
address register is incremented by one. Returns 0x8888 if read while
busy or a register read error occurred.
5
DATA_REG1_INERT Bits 31:16 of data to read or write. Reading or writing to this register does
not cause a register access to be initiated. Returns 0x8888 if a register
read error occurred.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
316
VCore-III System and CPU Interfaces
Table 243 • MIIM Registers (continued)
Register Address
Register Name
Description
6
STAT_REG
The status register gives the status of any ongoing operations.
Bit 0: Busy. Set while a register read/write operation is in progress.
Bit 1: Busy_rd. Busy status during the last read or write operation.
Bit 2: Err. Set if a register access error occurred.
Others: Reserved.
A 32-bit switch core register read or write transaction over the MIIM interface is done indirectly due to the
limited data width of the MIIM frame. First, the address of the register inside the device must be set in the
two 16-bit address registers of the MIIM slave using two MIIM write transactions. The two 16-bit data
registers can then be read or written to access the data value of the register inside the devices. Thus, it
requires up to four MIIM transactions to perform a single read or write operation on a register target.
The address of the register to read/write is set in registers ADDR_REG0 and ADDR_REG1. The data to
write to the register pointed to by the address in ADDR_REG0 and addr_reg1 is first written to
DATA_REG0 and then to DATA_REG1. When the write transaction to DATA_REG1 is completed, the
MIIM slave initiates the switch core register write.
With the register address of a specific register (REG_ADDR), the MIIM address (MIIM_ADDR) is
calculated as:
MIIM_ADDR = (REG_ADDR & 0x00FFFFFF)>>2
The following illustration shows a single MIIM write transaction on the MIIM interface.
Figure 97 • MIIM Slave Write Sequence
//
//
//
//
//
//
MDC
//
1
MDIO
0
1
0
1
//
//
PREAMBLE
32 bit
ST
2 bit
//
1
OP
2 bit
0
//
PHYAD
5 bit
//
REGAD
5 bit
TA
2 bit
DATA
16 bit
A read transaction is done in a similar way. First, read the DATA_REG0 and then read the DATA_REG1.
As with a write operation. The switch core register read is not initiated before the DATA_REG1 register is
read. In other words, the returned read value is from the previous read transaction.
The following illustration shows a single MIIM read transaction on the MIIM interface.
Figure 98 • MIIM Slave Read Sequence
MDC
MDIO
//
//
//
//
//
//
//
//
1
0
1
1
0
//
PREAMBLE
32 bit
ST
2 bit
OP
2 bit
//
//
Z
PHYAD
5 bit
REGAD
5 bit
0
//
TA
2 bit
DATA
16 bit
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
317
VCore-III System and CPU Interfaces
5.5.4
Access to the VCore Shared Bus
This section provides information about how to access the VCore shared bus (SBA) from an external
CPU attached by means of the VRAP, SI, or MIIM. The following table lists the registers associated with
the VCore shared bus access.
Table 244 • VCore Shared Bus Access Registers
Register
Description
DEVCPU_GCB::VA_CTRL
Status for ongoing access
DEVCPU_GCB::VA_ADDR
Configuration of shared bus address
DEVCPU_GCB::VA_DATA
Configuration of shared bus address
DEVCPU_GCB::VA_DATA_INCR
Data register, access increments VA_ADDR
DEVCPU_GCB::VA_DATA_INERT
Data register, access does not start new access
An external CPU perform 32-bit reads and writes to the SBA through the VCore Access (VA) registers. In
the VCore-III system, a dedicated master on the shared bus handles VA access. For information about
arbitration between masters on the shared bus, see VCore Shared Bus Arbitration.
The SBA address is configured in VA_ADDR. Writing to VA_DATA starts an SBA write with the 32-bit
value that was written to VA_DATA. Reading from VA_DATA returns the current value of the register and
starts an SBA read access, when the read access completes, the result is automatically stored in the
VA_DATA register.
The VA_DATA_INCR register behaves similar to VA_DATA, except that after starting an access, the
VA_ADDR register is incremented by four (so that it points to the next word address in the SBA domain).
Reading from the VA_DATA_INCR register returns the value of VA_DATA, writing to VA_DATA_INCR
overwrites the value of VA_DATA.
Note: By using VA_DATA_INCR, sequential word addresses can be accessed without having to manually
increment the VA_ADDR register between each access.
The VA_DATA_INERT register provides direct access to the VA_DATA value without starting access on
the SBA. Reading from the VA_DATA_INERT register returns the value of VA_DATA, writing to
VA_DATA_INERT overwrites the value of VA_DATA.
The VCore-III shared bus is capable of returning error-indication when illegal register regions are
accessed. If a VA access results in an error-indication from the SBA, the VA_CTRL.VA_ERR field is set,
and the VA_DATA is set to 0x88888888.
Note: SBA error indications only occur when non-existing memory regions or illegal registers are accessed.
This will not happen during normal operation, so the VA_CTRL.VA_ERR indication is useful during
debugging only.
Example Reading from ICPU_CFG::GPR[1] through the VA registers. The GPR register is the second
register in the SBA VCore-III Registers region. Set VA_ADDR to 0x70000004, read once from VA_DATA
(and discard the read value). Wait until VA_CTRL.VA_BUSY is cleared, then VA_DATA contains the
value of the ICPU_CFG::GPR[1] register. Using VA_DATA_INERT (instead of VA_DATA) to read the data
is appropriate, because this does not start a new SBA access.
5.5.4.1
Optimized Reading
VCore-III shared bus access is typically much faster than the CPU interface, which is used to access the
VA registers. The VA_DATA register (VA_DATA_INCR and VA_DATA_INERT) returns 0x88888888 when
VA_CTRL.VA_BUSY is set. This means that it is possible to skip checking for busy between read access
to SBA. For example, after initiating a read access from SBA, software can proceed directly to reading
from VA_DATA, VA_DATA_INCR, or VA_DATA_INERT:
•
If the second read is different from 0x88888888, then the second read returned valid read data (the
SBA access was done before the second read was performed).
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
318
VCore-III System and CPU Interfaces
•
If the second read is equal to 0x88888888, then the VA logic may have been busy during the read
and additional actions are required: First read the VA_CTRL.VA_BUSY field until the field is cleared
(VA logic is not busy). Then read VA_DATA_INERT. If VA_DATA_INERT returns 0x88888888, then
read-data is actually 0x88888888, continue to the next read. Otherwise, repeat the last read from
VA_DATA, VA_DATA_INCR, or VA_DATA_INERT and then continue to the next read from there.
Optimized reading can be used for single read and sequential read access. For sequential reads, the
VA_ADDR is only incremented on successful (non-busy) reads.
5.5.5
Mailbox and Semaphores
This section provides information about the semaphores and mailbox features for CPU to CPU
communication. The following table lists the registers associated with mailbox and semaphores.
Table 245 • Mailbox and Semaphore Registers
Register
Description
DEVCPU_ORG::MAILBOX_SET
Atomic set of bits in the mailbox register.
DEVCPU_ORG::MAILBOX_CLR
Atomic clear of bits in the mailbox register.
DEVCPU_ORG::MAILBOX
Current mailbox state.
DEVCPU_ORG::SEMA_CFG
Configuration of semaphore interrupts.
DEVCPU_ORG::SEMA0
Taking of semaphore 0.
DEVCPU_ORG::SEMA1
Taking of semaphore 1.
DEVCPU_ORG::SEMA0_OWNER
Current owner of semaphore 0.
DEVCPU_ORG::SEMA1_OWNER
Current owner of semaphore 1.
The mailbox is a 32-bit register that can be set and cleared atomically using any CPU interface (including
the VCore-III CPU). The MAILBOX register allows reading (and writing) of the current mailbox value.
Atomic clear of individual bits in the mailbox register is done by writing a mask to MAILBOX_CLR. Atomic
setting of individual bits in the mailbox register is done by writing a mask to MAILBOX_SET.
The devices implement two independent semaphores. The semaphores are part of the Switch Core
Register Bus (CSR) block and are accessible by means of the fast switch core registers. Semaphore
ownership can be taken by interfaces attached to the CSR. That is, the VCore-III, VRAP, SI, and MIIM
can be granted ownership. The VCore-III CPU and PCIe interface share the same semaphore, because
they both access the CSR through the switch core access block.
Any CPU attached to an interface can attempt to take a semaphore n by reading SEMA0.SEMA0 or
SEMA1.SEMA1. If the result is 1, the corresponding semaphore was successfully taken and is now
owned by that interface. If the result is 0, the semaphore was not free. After a successfully taking a
semaphore, all additional reads from the corresponding register will return 0. To release a semaphore
write 1 to SEMA0.SEMA0 or SEMA1.SEMA1.
Any interface can release semaphores; it does not have to the one that has taken the semaphore. This
allows implementation of handshaking protocols.
The current status for a semaphore is available in SEMA0_OWNER.SEMA0_OWNER and
SEMA1_OWNER.SEMA1_OWNER. See register description for encoding of owners.
Software interrupt is generated when semaphores are free or taken. Interrupt polarity is configured
through SEMA_CFG.SEMA_INTR_POL. Semaphore 0 is hooked up to SW0 interrupt and semaphore 1
is hooked up to SW1 interrupt. For configuration of software-interrupt, see Interrupt Controller.
In addition to interrupting on semaphore state, software interrupt can be manually triggered by writing
directly to the ICPU_CFG::INTR_FORCE register.
Software interrupts (SW0 and SW1) can be individually mapped to either the VCore-III CPU or to
external interrupt outputs (to an external CPU).
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
319
VCore-III System and CPU Interfaces
5.6
PCIe Endpoint Controller
The devices implement a single-lane PCIe 1.x endpoint that can be hooked up to any PCIe capable
system. Using the PCIe interface, an external CPU can access (and control) the devices. Ethernet
frames can be injected and extracted using registers or the devices can be configured to DMA Ethernet
frames autonomously to/from PCIe memory. The device’s DDR3/DDR3L memory is available through
the PCIe interface, allowing the external CPU full read and write access to DDR3/DDR3L modules
attached to the devices. The DDR3/DDR3L controller and memory modules can be initialized either by
PCIe or by the VCore-III CPU.
Both the VCore-III CPU and Frame DMA can generate PCIe read/write requests to any 32-bit or 64-bit
memory region in PCIe memory space. However, it is up to software running on an external CPU to set
up or communicate the appropriate PCIe memory mapping information to the devices.
The defaults for the endpoints capabilities region and the extended capabilities region are listed in the
registers list’s description of the PCIE registers. The most important parameters are:
•
•
•
•
•
Vendor (and subsystem vendor) ID: 0x101B, Microsemi
Device ID: 0xB003, device family ID
Revision ID: 0x00, device family revision ID
Class Code: 0x028000, Ethernet Network controller
Single function, non-Bridge, INTA and Message Signaled Interrupt (MSI) capable device
The device family 0xB003 covers several register compatible devices, the software driver must
determine actual device ID and revision by reading DEVCPU_GCB::CHIP_ID from the device’s memory
mapped registers region.
For information about base address registers, see Base Address Registers, Inbound Requests.
The IDs, class code, revision ID, and base address register setups can be customized before enabling
the PCIe endpoint. However, it requires a manual bring-up procedure by software running locally on the
VCore-III CPU. For more information, see Enabling the Endpoint.
The endpoint is power management capable and implements PCI Bus Power Management Interface
Specification Revision 1.2. For more information, see Power Management.
The endpoint is MSI capable. Up to four 64-bit messages are supported. Messages can be generated on
rising and falling edges of each of the two external VCore-III interrupt destinations. For more information,
see Outbound Interrupts.
For information about all PCI Express capabilities and extended capabilities register defaults, see the
PCIE region’s register descriptions.
5.6.1
Accessing Endpoint Registers
The root complex accesses the PCIe endpoint’s configuration registers by PCIe CfgRd/CfgWr requests.
The VCore-III CPU can read configuration registers by means of the PCIE region. For more information,
see Chip Register Region. The PCIE region must not be accessed when the PCIe endpoint is disabled.
The PCIe region is used during manual bring-up of PCIe endpoint. By using this region, it is possible to
write most of the endpoint’s read-only configuration registers, such as Vendor ID. The PCIe endpoint’s
read-only configuration register values must not be changed after the endpoint is enabled.
The VCore-III has a few dedicated PCIe registers in the ICPU_CFG:PCIE register group. An external
CPU attached through the PCIe interface has to go through BAR0 to reach these registers.
5.6.2
Enabling the Endpoint
The PCIe endpoint is disabled by default. It can be enabled automatically or manually by either setting
the VCore_CFG strapping pins or by software running in the VCore-III CPU.
The recommended approach is using VCore_CFG strapping pins, because it is fast and does not require
special software running on the VCore-III CPU. The endpoint is ready approximately 50 ms after release
of the device’s nRESET. Until this point, the devices ignore any attempts to do link training, and the PCIe
output remains idle (tristated).
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
320
VCore-III System and CPU Interfaces
By using software running on the VCore-III CPU, it is possible to manually start the PCIe endpoint. Note
that PCIe standard specifies a maximum delay from nRESET release to working PCIe endpoint so
software must enable the endpoint as part of the boot process.
The root complex must follow standard PCIe procedures for bringing up the endpoint.
5.6.2.1
Manually Starting MAC/PCS and SerDes
This section provides information about how to manually start up the PCIe endpoint and customize
selected configuration space parameters.
The following table lists the registers related to manually bringing up PCIe.
Table 246 • Manual PCIe Bring-Up Registers
Register
Description
ICPU_CFG::PCIE_CFG
Disable of automatic link initialization
HSIO::SERDES6G_COMMON_CFG
SERDES configuration
HSIO::SERDES6G_MISC_CFG
SERDES configuration
HSIO::SERDES6G_IB_CFG
SERDES configuration
HSIO::SERDES6G_IB_CFG1
SERDES configuration
HSIO::SERDES6G_SER_CFG
SERDES configuration
HSIO::SERDES6G_OB_CFG1
SERDES configuration
HSIO::SERDES6G_DES_CFG
SERDES configuration
HSIO::SERDES6G_PLL_CFG
SERDES configuration
HSIO::SERDES6G_MISC_CFG
SERDES configuration
HSIO::MCB_SERDES6G_ADDR_CFG
SERDES configuration
PCIE::DEVICE_ID_VENDOR_ID,
Device parameter customization
PCIE::CLASS_CODE_REVISION_ID,
PCIE::SUBSYSTEM_ID_SUBSYSTEM_VENDOR_
ID
PCIE::BAR1, PCIE::BAR2
Base address register customization
To disable automatic link training for PCIe endpoint, perform the following steps.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
SERDES6G_MISC_CFG = 0x00000031.
SERDES6G_OB_CFG1 = 0x000000B0.
SERDES6G_DES_CFG = 0x000060A6.
SERDES6G_IB_CFG = 0x3D57AC37.
SERDES6G_IB_CFG1 = 0x00110FF0.
SERDES6G_SER_CFG = 0x00000000.
SERDES6G_PLL_CFG = 0x00030F00.
SERDES6G_COMMON_CFG = 0x00014009.
MCB_SERDES6G_ADDR_CFG = 0x81000000 and wait until bit 31 is cleared.
SERDES6G_PLL_CFG = 0x00030F20.
MCB_SERDES6G_ADDR_CFG = 0x81000000 and wait until bit 31 is cleared.
Wait at least 20 ms.
SERDES6G_IB_CFG = 0x3D57AC3F.
SERDES6G_MISC_CFG = 0x00000030.
MCB_SERDES6G_ADDR_CFG = 0x81000000 and wait until bit 31 is cleared.
Wait at least 15 ms.
SERDES6G_IB_CFG = 0x3D57ACBF.
SERDES6G_IB_CFG1 = 0x00103FF0.
MCB_SERDES6G_ADDR_CFG = 0x81000000 and wait until bit 31 is cleared.
To optionally disable BAR1:
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
321
VCore-III System and CPU Interfaces
1.
2.
3.
PCIE_CFG.PCIE_BAR_WR_ENA = 1
BAR1 = 0x00000000
PCIE_CFG.PCIE_BAR_WR_ENA = 0
To optionally increase BAR2 from 128 to 256 megabytes:
1.
2.
3.
PCIE_CFG.PCIE_BAR_WR_ENA = 1
BAR2 = 0x0FFFFFFF
PCIE_CFG.PCIE_BAR_WR_ENA = 0
To optionally change selected PCIe configuration space values:
•
•
•
Write Vendor ID/Device ID using DEVICE_ID_VENDOR_ID.
Write Class Code/Revision ID using CLASS_CODE_REVISION_ID.
Write Subsystem ID/Subsystem Vendor ID using SUBSYSTEM_ID_SUBSYSTEM_VENDOR_ID.
Enable automatic link training for PCIe endpoint
1.
PCIE_CFG.LTSSM_DIS = 0
The last step enables the endpoint for link training, and the root complex will then be able to initialize the
PCIe endpoint. After this the PCIE parameters must not be changed anymore.
5.6.3
Base Address Registers Inbound Requests
The devices implement three memory regions. Read and write operations using the PCIe are translated
directly to read and write access on the SBA. When manually bringing up the PCIe endpoint, BAR1 can
be disabled. For more information, see Manually Starting MAC/PCS and SerDes.
Table 247 • Base Address Registers
Register
Description
BAR0, 32-bit, 32 megabytes
Chip registers region. This region maps to the Chip registers
region in the SBA address space. See Chip Register Region.
This region only supports 32-bit word-aligned reads and
writes. Single and burst accesses are supported.
BAR1, 32-bit, 16 megabytes
SI Flash region. This region maps to the SI Flash region in the
SBA address space. See SI Flash Region.
This region only supports 32-bit word-aligned reads. Single
and burst access is supported.
BAR2, 32-bit, 128 megabytes
DDR3/DDR3L region. This region maps to the low 128
megabytes of the DDR3/DDR3L region in the SBA address
space. See DDR3/DDR3L Region.
This region support all access types.
To access the BAR1 region, a Flash must be attached to the SI interface of the VSC7442-02,
VSC7444-02, VSC7448-02, and VSC7449-02 devices. For information about how to set up I/O timing
and to program the Flash through BAR0; the Chip Registers Region, see SI Boot Controller, page 334.
To access the BAR2 region, DDR3/DDR3L modules must be present and initialized. For information
about initializing the DDR3/DDR3L controller and modules through BAR0; the Chip Registers, see
DDR3/DDR3L Memory Controller. During manual bring up of PCIe, the size of the BAR2 region can be
changed to match the size of the attached DDR3/DDR3L modules. For more information, see Manually
Starting MAC/PCS and SerDes.
5.6.4
Outbound Interrupts
The devices supports both Message Signaled Interrupt (MSI) and Legacy PCI Interrupt Delivery. The root
complex configures the desired mode using the MSI enable bit in the PCIe MSI Capability Register Set.
For information about the VCore-III interrupt controller, see Interrupt Controller, page 367.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
322
VCore-III System and CPU Interfaces
The following table lists the device registers associated PCIe outbound interrupts.
Table 248 • PCIe Outbound Interrupt Registers
Register
Description
ICPU_CFG::PCIE_INTR_COMMON_CFG
Interrupt mode and enable
ICPU_CFG::PCIE_INTR_CFG
MSI parameters
In legacy mode, one interrupt is supported; select either EXT_DST0 or EXT_DST1 using
PCIE_INTR_COMMON_CFG.LEGASY_MODE_INTR_SEL. The PCIe endpoint uses Assert_INTA and
Deassert_INTA messages when configured for legacy mode.
In MSI mode, both EXT_DST interrupts can be used. EXT_DST0 is configured though
PCIE_INTR_CFG[0] and EXT_DST1 through PCIE_INTR_CFG[1]. Enable message generation on rising
and/or falling edges in PCIE_INTR_CFG[n].INTR_RISING_ENA and
PCIE_INTR_CFG[n].INTR_FALLING_ENA. Different vectors can be generated for rising and falling
edges, configure these through PCIE_INTR_CFG[n].RISING_VECTOR_VAL and
PCIE_INTR_CFG[n].FALLING_VECTOR_VAL. Finally, each EXT_DST interrupt must be given an
appropriate traffic class via PCIE_INTR_CFG[n].TRAFFIC_CLASS.
After the root complex has configured the PCIe endpoint’s MSI Capability Register Set and the external
CPU has configured how interrupts from the VCore-III interrupt controller are propagated to PCIe,
interrupts must then be enabled by setting PCIE_INTR_COMMON_CFG.PCIE_INTR_ENA.
5.6.5
Outbound Access
After the PCIe endpoint is initialized, outbound read/write access to PCIe memory space is initiated by
reading or writing the SBA’s PCIe DMA region.
The following table lists the device registers associated with PCIe outbound access.
Table 249 • Outbound Access Registers
Register
Description
ICPU_CFG::PCIESLV_SBA
Configures SBA outbound requests.
ICPU_CFG::PCIESLV_FDMA
Configures FDMA outbound requests.
PCIE::ATU_REGION
Select active region for the ATU_* registers.
PCIE::ATU_CFG1
Configures TLP fields.
PCIE::ATU_CFG2
Enable address translation.
PCIE::ATU_TGT_ADDR_LOW
Configures outbound PCIe address.
PCIE::ATU_TGT_ADDR_HIGH
Configures outbound PCIe address.
The PCIe DMA region is 1 gigabyte. Access in this region is mapped to any 1 gigabyte region in 32-bit or
64-bit PCIe memory space by using address translation. Two address translation regions are supported.
The recommended approach is to configure the first region for SBA outbound access and the second
region for FDMA outbound access.
Address translation works by taking bits [29:0] from the SBA/FDMA address, adding a configurable
offset, and then using the resulting address to access into PCIe memory space. Offsets are configurable
in steps of 64 kilobytes in the ATU_TGT_ADDR_HIGH and ATU_TGT_ADDR_LOW registers.
The software on the VCore-III CPU (or other SBA masters) can dynamically reconfigure the window as
needed; however, the FDMA does not have that ability, so it must be disabled while updating the 1
gigabyte window that is set up for it.
Note: Although the SBA and FDMA both access the PCIe DMA region by addresses 0xC0000000 though
0xFFFFFFFF, the PCIe address translation unit can differentiate between these accesses and apply the
appropriate translation.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
323
VCore-III System and CPU Interfaces
5.6.5.1
Outbound SBA Translation Region Configuration
Configure PCIESLV_SBA.SBA_OFFSET = 0 and select address translation region 0 by writing
ATU_REGION.ATU_IDX = 0. Set PCIE::ATU_BASE_ADDR_LOW.ATU_BASE_ADDR_LOW = 0x0000
and PCIE::ATU_LIMIT_ADDR.ATU_LIMIT_ADDR = 0x3FFF.
The following table lists the appropriate PCIe headers that must be configured before using the SBA’s
PCIe DMA region. Remaining header fields are automatically handled.
Table 250 • PCIe Access Header Fields
Header Field
Register::Fields
Attributes
ATU_CFG1.ATU_ATTR
Poisoned Data
PCIESLV_SBA.SBA_EP
TLP Digest Field Present
ATU_CFG1.ATU_TD
Traffic Class
ATU_CFG1.ATU_TC
Type
ATU_CFG1.ATU_TYPE
Byte Enables
PCIESLV_SBA.SBA_BE
Message Code
ATU_CFG2.ATU_MSG_CODE
Configure the low address of the destination window in PCIe memory space as follows:
•
•
Set ATU_TGT_ADDR_HIGH.ATU_TGT_ADDR_HIGH to bits [63:32] of the destination window. Set
to 0 when a 32-bit address must be generated.
Set ATU_TGT_ADDR_LOW.ATU_TGT_ADDR_LOW to bits [31:16] of the destination window. This
field must not be set higher than 0xC000.
Enable address translation by writing ATU_CFG2.ATU_REGION_ENA = 1. SBA access in the PCIe
DMA region is then mapped to PCIe memory space as defined by ATU_TGT_ADDR_LOW and
ATU_TGT_ADDR_HIGH.
The header fields and the PCIe address fields can be reconfigured on-the-fly as needed; however, set
ATU_REGION.ATU_IDX to 0 to ensure that the SBA region is selected.
5.6.5.2
Configuring Outbound FDMA Translation Region
Configure PCIESLV_FDMA.FDMA_OFFSET = 1, and select address translation region 1 by writing
ATU_REGION.ATU_IDX = 1.
Set PCIE::ATU_BASE_ADDR_LOW.ATU_BASE_ADDR_LOW = 0x4000 and
PCIE::ATU_LIMIT_ADDR.ATU_LIMIT_ADDR = 0x7FFF.
The FDMA PCIe header must be MRd/MWr type, reorderable, cache-coherent, and without ECRC.
Remaining header fields are automatically handled.
Table 251 • FDMA PCIe Access Header Fields
Header Field
Register::Fields
Suggested Value
Attributes
ATU_CFG1.ATU_ATTR
Set to 2
TLP Digest Field Present
ATU_CFG1.ATU_TD
Set to 0
Traffic Class
ATU_CFG1.ATU_TC
Use an appropriate traffic class
Type
ATU_CFG1.ATU_TYPE
Set to 0
Configure low address of destination window in PCIe memory space as follows:
•
Set ATU_TGT_ADDR_HIGH.ATU_TGT_ADDR_HIGH to bits [63:32] of the destination window. Set
to 0 when a 32-bit address must be generated.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
324
VCore-III System and CPU Interfaces
•
Set ATU_TGT_ADDR_LOW.ATU_TGT_ADDR_LOW to bits [31:16] of the destination window. This
field must not be set higher than 0xC000.
Enable address translation by writing ATU_CFG2.ATU_REGION_ENA = 1. The FDMA can be
configured to make access in the 0xC0000000 - 0xFFFFFFFF address region. These accesses will then
be mapped to PCIe memory space as defined by ATU_TGT_ADDR_LOW and ATU_TGT_ADDR_HIGH.
The FDMA must be disabled if the address window needs to be updated.
5.6.6
Power Management
The device’s PCIe endpoint supports D0, D1, and D3 device power-management states and associated
link power-management states. The switch core does not automatically react to changes in the PCIe
endpoint’s power management states. It is, however, possible to enable a VCore-III interrupt on device
power state changes and then have the VCore-III CPU software make application-specific changes to
the device operation depending on the power management state.
Table 252 • Power Management Registers
Register
Description
ICPU_CFG::PCIE_STAT
Current power management state
ICPU_CFG::PCIEPCS_CFG
Configuration of WAKE output and beacon
ICPU_CFG::PCIE_INTR
PCIe interrupt sticky events
ICPU_CFG::PCIE_INTR_ENA
Enable of PCIe interrupts
ICPU_CFG::PCIE_INTR_IDENT
Currently interrupting PCIe sources
ICPU_CFG::PCIE_AUX_CFG
Configuration of auxiliary power detection
Because the devices do not implement a dedicated auxiliary power for the PCIe endpoint, the endpoint is
operated from the VDD core power supply. Before the power management driver initializes the device,
software can “force” auxiliary power detection by writing PCIE_AUX_CFG = 3, which causes the
endpoint to report that it is capable of emitting Power Management Events (PME) messages in the D3c
state.
The current device power management state is available using PCIE_STAT.PM_STATE. A change in this
field’s value sets the PCIE_INTR.INTR_PM_STATE sticky bit. To enable this interrupt, set
PCIE_INTR_ENA.INTR_PM_STATE_ENA. The current state of the PCIe endpoint interrupt towards the
VCore-III interrupt controller is shown in PCIE_INTR_IDENT register (if different from zero, then interrupt
is active).
The endpoint can emit PMEs if the PME_En bit is set in the PM Capability Register Set and if the
endpoint is in power-down mode.
•
•
Outbound request from either SBA or FDMA trigger PME.
A change in status for an enabled outbound interrupt (either legacy or MSI) triggers PME. This
feature can be disabled by setting
ICPU_CFG::PCIE_INTR_COMMON_CFG.WAKEUP_ON_INTR_DIS.
In the D3 state, the endpoint transmits a beacon. The beacon function can be disabled and instead drive
the WAKE output using the overlaid GPIO function. For more information about the overlaid function on
the GPIO for this signal, see GPIO Overlaid Functions, page 354.
Table 253 • PCIe Wake Pin
Pin Name
I/O
Description
PCIe_WAKE/GPIO
O
PCIe WAKE output
Enable WAKE by setting PCIEPCS_CFG.BEACON_DIS. The polarity of the WAKE output is configured
in PCIEPCS_CFG.WAKE_POL. The drive scheme is configured in PCIEPCS_CFG.WAKE_OE.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
325
VCore-III System and CPU Interfaces
5.6.7
Device Reset Using PCIe
The built-in PCIe reset mechanism in the PCIe endpoint resets only the PCIe MAC. The device reset is
not tied into the MAC reset. To reset the complete the device, use the following procedure.
1.
2.
3.
4.
Save the state of the PCIe controller registers using operating system.
Set DEVCPU_GCB::SOFT_RST.SOFT_CHIP_RST.
Wait for 100 ms.
Recover state of PCIe controller registers using operating system.
Setting SOFT_CHIP_RST will cause re-initialization of the device.
5.7
Frame DMA
This section describes the Frame DMA engine (FDMA). When FDMA is enabled, Ethernet frames can be
extracted or injected autonomously to or from the device’s DDR3/DDR3L memory and/or PCIe memory
space. Linked list data structures in memory are used for injecting or extracting Ethernet frames. The
FDMA generates interrupts when frame extraction or injection is done and when the linked lists needs
updating.
Table 254 • FDMA Registers
Register
Description
DEVCPU_QS::XTR_GRP_CFG
CPU port ownership, extraction direction.
DEVCPU_QS::INJ_GRP_CFG
CPU port ownership, injection direction.
DEVCPU_QS::INJ_CTRL
Injection EOF to SOF spacing.
ASM::PORT_CFG
Enables IFH and disables FCS recalculation (for injected
frames).
SYS::PORT_MODE
Enables IFH for extraction frames.
ICPU_CFG::FDMA_CH_CFG
Channel configuration, priorities, and so on.
ICPU_CFG::FDMA_CH_ACTIVATE
Enables channels.
ICPU_CFG::FDMA_CH_DISABLE
Disables channels.
ICPU_CFG::FDMA_CH_STAT
Status for channels.
ICPU_CFG::FDMA_CH_SAFE
Sets when safe to update channel linked lists.
ICPU_CFG::FDMA_DCB_LLP
Linked list pointer for channels.
ICPU_CFG::FDMA_DCB_LLP_PREV
Previous linked list pointer for channels.
ICPU_CFG::FDMA_CH_CNT
Software counters for channels.
ICPU_CFG::FDMA_INTR_LLP
NULL pointer event for channels.
ICPU_CFG::FDMA_INTR_LLP_ENA
Enables interrupt on NULL pointer event.
ICPU_CFG::FDMA_INTR_FRM
Frame done event for channels.
ICPU_CFG::FDMA_INTR_FRM_ENA
Enables interrupt on frame done event.
ICPU_CFG::FDMA_INTR_SIG
SIG counter incremented event for channels.
ICPU_CFG::FDMA_INTR_SIG_ENA
Enables interrupt on SIG counter event.
ICPU_CFG::MANUAL_INTR
Manual injection/extraction events.
ICPU_CFG::MANUAL_INTR_ENA
Enables interrupts on manual injection/extraction events.
ICPU_CFG::FDMA_EVT_ERR
Error event for channels.
ICPU_CFG::FDMA_EVT_ERR_CODE
Error event description.
ICPU_CFG::FDMA_INTR_ENA
Enables interrupt for channels.
ICPU_CFG::FDMA_INTR_IDENT
Currently interrupting channels.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
326
VCore-III System and CPU Interfaces
Table 254 • FDMA Registers (continued)
Register
Description
DEVCPU_QS::XTR_FRM_PRUNING
Enables pruning of extraction frames.
ICPU_CFG::FDMA_CH_INJ_TOKEN_CNT
Injection tokens.
ICPU_CFG::FDMA_CH_INJ_TOKEN_TICK_RLD
Periodic addition of injection tokens.
ICPU_CFG::MANUAL_CFG
Configures manual injection/extraction.
ICPU_CFG::MANUAL_XTR
Memory region used for manual extraction.
ICPU_CFG::MANUAL_INJ
Memory region used for manual injection.
DEVCPU_QS::INJ_CTRL
Configures injection gap.
ICPU_CFG::FDMA_GCFG
Configures injection buffer watermark.
The FDMA implements two extraction channels per CPU port and a total of eight injection channels.
Extraction channels are hard-coded per CPU port, and injection channels can be individually assigned to
any CPU port.
•
•
•
•
FDMA channel 0 corresponds to port 53 (group 0) extraction direction.
FDMA channel 1 corresponds to port 54 (group 1) extraction direction.
FDMA channel 2 through 9 corresponds to port 53 (group 0) injection direction when
FDMA_CH_CFG[channel].CH_INJ_GRP is set to 0.
FDMA channel 2 through 9 corresponds to port 54 (group 1) injection direction when
FDMA_CH_CFG[channel].CH_INJ_GRP is set to 1.
The FDMA implements a strict priority scheme. Injection and extraction channels can be assigned
individual priorities, which are used when the FDMA has to decide between servicing two or more
channels. Channel priority is configured in FDMA_CH_CFG[ch].CH_PRIO. When channels have same
priority, the higher channel number takes priority over the lower channel number.
When more than one injection channel is enabled for injection on the same CPU port, then priority
determines which channel that is allowed to inject data. Ownership is re-arbitrated on frame boundaries.
The internal frame header is added in front of extracted frames and provides useful switching information
about the extracted frames.
Injection frames requires an internal frame header for controlling injection parameters. The internal frame
header is added in front of frame data. The devices recalculate and overwrite the Ethernet FCS for
frames that are injected via the CPU when requested by setting in the internal frame header.
For more information about the extraction and injection IFH, see Frame Headers, page 14.
The FDMA supports a manual mode where the FDMA decision logic is disabled and the FDMA takes and
provides data in the order that was requested by an external master (internal or external CPU). The
manual mode is a special case of normal FDMA operation where only few of the FDMA features apply.
For more information about manual operation, see Manual Mode.
The following configuration must be performed before enabling FDMA extraction: Set
XTR_GRP_CFG[group].MODE = 2.
The following configurations must be performed before enabling FDMA injection: Set
INJ_GRP_CFG[group].MODE = 2. Set INJ_CTRL[group].GAP_SIZE = 0, set
PORT_CFG[port].INJ_FORMAT_CFG = 1, set PORT_CFG[port].NO_PREAMBLE_ENA = 1, and set
PORT_CFG[port].VSTAX2_AWR_ENA = 0.
5.7.1
DMA Control Block Structures
The FDMA processes linked lists of DMA Control Block Structures (DCBs). The DCBs have the same
basic structure for both injection or for extraction. A DCB must be placed on a 32-bit word-aligned
address in memory. Each DCB must have an associated data block that is placed on a 32-bit word
aligned address in memory, the length of the data block must be a complete number of 32-bit words.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
327
VCore-III System and CPU Interfaces
An Ethernet frame can be contained inside one data block (if the data block is big enough) or the frame
can be spread across multiple data blocks. A data block never contains more than one Ethernet frame.
Data blocks that contain start-of-frame have set a special bit in the DCB’s status word, likewise for data
blocks that contains end of frame. The FDMA stores or retrieves Ethernet frame data in network order.
This means that the data at byte address (n) of a frame was received just before the data at byte address
(n + 1).
Frame data inside the DCB’s associated data blocks can be placed at any byte offset and have any byte
length as long as byte offset and length does not exceed the size of the data block. Byte offset and length
is configured using special fields inside the DCB status word. Software can specify offset both when
setting up extraction and injection DCBs. Software only specifies length for injection DCBs; the FDMA
automatically calculates and updates length for extraction.
Example If a DCB’s status word has block offset 5 and block length 2, then the DCB’s data block
contains two bytes of frame data placed at second and third bytes inside the second 32-bit word of the
DCB’s associated data block.
DCBs are linked together by the DCB’s LLP field. The last DCB in a chain must have LLP = NULL.
Chains consisting of a single DCB are allowed.
Figure 99 • FDMA DCB Layout
LLP [31:0]: Linked List Pointer, this field points to the next DCB in the list, set to NULL for
end of list. DCBs must be word-aligned, which means LLP must point to a word-aligned
address (bit [1:0] = 00).
LLP
n+1
DATAP [31:0]: Data block pointer, this field points to the data block associated with this
DCB. DATAP must be !=NULL and must point to a word-aligned address (bit [1:0] = 00).
DATAP
n+2
[31:24]: For SW
use. FDMA will not
modify.
word-address n
n+3
[23:18]:
Must be 0.
17 16
BLOCKO [31:20]: Byte offset
from beginning of the data block 19 18 17 16
to the first byte of frame-data.
DATAL [15:0]: Number of bytes available in
the data block associated with this DCB.
DATAL must be a complete number of words
(bit [1:0] = 00).
BLOCKL [15:0]: Number of frame-data
bytes in the data block. BLOCKL does not
include offset bytes.
DATAL
STAT
STAT[16] SOF: Set to 1 if data block contains start of frame.
STAT[17] EOF: Set to 1 if data block contains end of frame.
STAT[18] ABORT: Abort indication.
Extraction: Set to 1 if the frame associated with the data block was aborted.
Injection: If set to 1 when FDMA loads the DCB, it aborts the frame associated with the data block.
STAT[19] PD: Pruned/Done indication.
Extraction: Set to 1 if the frame associated with the data block was pruned.
Injection: The FDMA set this to 1 when done processing the DCB. If set to 1 when FDMA loads the DCB, it
is treated as ABORT.
DATAL[16] SIG: If set to 1 when FDMA loads the DCB, the CH_CNT_SIG counter is incremented by one.
DATAL[17] TOKEN: Token indication, only used during injection.
If set to 1, the FDMA uses one token (CH_INJ_TOKEN_CNT) when injecting the contents of the DCB. If the
token counter is 0 when loading the DCB, then injection is postponed until tokens are made available.
5.7.2
Enabling and Disabling FDMA Channels
To enable a channel (ch), write a valid DCB pointer to FDMA_DCB_LLP[ch] and enable the channel by
setting FDMA_CH_ACTIVATE.CH_ACTIVATE[ch]. This makes the FDMA load the DCB from memory
and start either injection or extraction.
To schedule a channel for disabling, set FDMA_CH_DISABLE.CH_DISABLE[ch]. An active channel
does not disable immediately. Instead it waits until the current data block is done, saves the status word,
and then disables.
Channels can be in one of three states: DISABLED, UPDATING, or ACTIVE. Channels are DISABLED
by default. When the channel is reading a DCB or writing the DCB status word, it is considered to be
UPDATING. The status of individual channels is available in FDMA_CH_STAT.CH_STAT[ch].
The following illustration shows the FDMA channel states.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
328
VCore-III System and CPU Interfaces
Figure 100 • FDMA Channel States
DISABLED
Enable when user requested
ACTIVATE of channel.
Disable when DCB.LLP == NULL or
user requested DISABLE of channel.
UPDATING
Load DCB from address
ICPU_CFG::FDMA_DCB_LLP[ch].
Update STAT word at address
ICPU_CFG::FDMA_DCB_LLP_PREV[ch] + 0xC.
ACTIVE
A channel that has FDMA_DCB_LLP[ch].DCB_LLP==NULL when going from ACTIVE to UPDATING
disables itself instead of loading a new DCB. After this it can be re-enabled as previously described.
Extraction channels emit an INTR_LLP-event when loading a DCB with LLP==NULL. Injection channels
emit an INTR_LLP-event when saving status for a DCB that has the LLP==NULL.
Note: Extraction channel running out of DCBs during extraction is a problem that software must avoid. A
hanging extraction channel will potentially be head-of-line blocking other extraction channels.
It is possible to update an active channels LLP pointer and pointers in the DCB chains. Before changing
pointers software must schedule the channel for disabling (by writing
FDMA_CH_DISABLE.CH_DISABLE[ch]) and then wait for the channel to set
FDMA_CH_SAFE.CH_SAFE[ch]. When the pointer update is complete, soft must re-activate the channel
by setting FDMA_CH_ACTIVATE.CH_ACTIVATE[ch]. Setting activate will cancel the deactivate-request,
or if the channel has disabled itself in the meantime, it will re activate the channel.
Note: The address of the current DCB is available in FDMA_DCB_LLP_PREV[ch]. This information is useful
when modifying pointers for an active channel. The FDMA does not reload the current DCB when reactivated, so if the LLP-field of the current DCB is modified, then software must also modify
FDMA_DCB_LLP[ch].
Setting FDMA_CH_CFG[ch].DONEEOF_STOP_ENA disables an FDMA channel and emits LLP-event
after saving status for DCBs that contains EOF (after extracting or injecting a complete frame). Setting
FDMA_CH_CFG[ch].DONE_STOP_ENA disables an FDMA channel and emits LLP-event after saving
status for any DCB.
5.7.3
Channel Counters
The FDMA implements three counters per channel: SIG, DCB, and FRM. These counters are accessible
through FDMA_CH_CNT[ch].CH_CNT_SIG, FDMA_CH_CNT[ch].CH_CNT_DCB, and
FDMA_CH_CNT[ch].CH_CNT_FRM, respectively. For more information about how to safely modify
these counters, see the register descriptions.
•
The SIG (signal) counter is incremented by one each time the FDMA loads a DCB that has the
DATAL.SIG bit set to 1.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
329
VCore-III System and CPU Interfaces
•
•
The FRM (frame) counter is incremented by one each time the FDMA store status word for DCB that
has EOF set. It is a wrapping counter that can be used for software driver debug and development.
This counter does not count aborted frames.
The DCB counter is incremented by one every time the FDMA loads a DCB from memory. It is a
wrapping counter that can be used for software driver debug and development.
It is possible to enable channel interrupt whenever the SIG counter is incremented; this makes it possible
for software to receive interrupt when the FDMA reaches certain points in a DCB chain.
5.7.4
FDMA Events and Interrupts
Each FDMA channel can generate four events: LLP-event, FRM-event, SIG-event, and ERR-event.
These events cause a bit to be set in FDMA_INTR_LLP.INTR_LLP[ch],
FDMA_INTR_FRM.INTR_FRM[ch], FDMA_INTR_SIG.INTR_SIG[ch], and
FDMA_EVT_ERR.EVT_ERR[ch], respectively.
•
•
•
•
LLP-event occurs when an extraction channel loads a DCB that has LLP = NULL or when an
injection channel writes status for a DCB that has LLP=NULL. LLP-events are also emitted from
channels that have FDMA_CH_CFG[ch].DONEEOF_STOP_ENA or
FDMA_CH_CFG[ch].DONE_STOP_ENA set. For more information, see Enabling and Disabling
FDMA Channels.
FRM-event is indicated when an active channel loads a new DCB and the previous DCB had EOF.
The FRM-event is also indicated for channels that are disabled after writing DCB status with EOF.
SIG-event is indicated whenever the FDMA_CH_CNT[ch].CH_CNT_SIG counter is incremented.
The SIG (signal) counter is incremented when loading a DCB that has the DATAL.SIG bit set.
ERR-event is an error indication that is set for a channel if it encounters an unexpected problem
during normal operation. This indication is implemented to ease software driver debugging and
development. A channel that encounters an error will be disabled, depending on the type of error the
channel state may be too corrupt for it to be restarted without system reset. When an ERR-event
occurs, the FDMA_EVT_ERR_CODE.EVT_ERR_CODE shows the exact reason for an ERR-event.
For more information about the errors that are detected, see
FDMA_EVT_ERR_CODE.EVT_ERR_CODE.
Each of the events (LLP, FRM, SIG) can be enabled for channel interrupt through
FDMA_INTR_LLP_ENA.INTR_LLP_ENA[ch], FDMA_INTR_FRM_ENA.INTR_FRM_ENA[ch], and
FDMA_INTR_SIG.INTR_SIG[ch] respectively. The ERR event is always enabled for channel interrupt.
The highest numbered extraction channel supports two additional non-sticky events related to manual
extraction: XTR_SOF_RDY-event and XTR_ANY_RDY-event. An active event causes the following fields
to be set: MANUAL_INTR.INTR_XTR_SOF_RDY and MANUAL_INTR.INTR_XTR_ANY_RDY
respectively. For more information, see Manual Extraction.
•
•
XTR_SOF_RDY-event is active when the next word to be manually extracted contains an SOF
indication. This event is enabled in MANUAL_INTR_ENA.INTR_XTR_SOF_RDY_ENA.
XTR_ANY_RDY-event is active when any word is available for manually extraction. This event is
enabled in MANUAL_INTR_ENA.INTR_XTR_ANY_RDY_ENA respectively.
The highest numbered injection channel supports one additional non-sticky event related to manual
injection: INJ_RDY-event. This event is active when the injection logic has room for (at least) sixteen 32bit words of injection frame data. When this event is active, MANUAL_INTR.INTR_INJ_RDY is set. The
INJ_RDY-event can be enabled for channel interrupt by setting
MANUAL_INTR_ENA.INTR_INJ_RDY_ENA. For more information, see Manual Injection.
The FDMA_INTR_ENA.INTR_ENA[ch] field enables interrupt from individual channels,
FDMA_INTR_IDENT.INTR_IDENT[ch] field shows which channels that are currently interrupting. While
INTR_IDENT is non-zero, the FDMA is indicating interrupting towards to the VCore-III interrupt controller.
The following illustration shows the FDMA channel interrupt hierarchy.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
330
VCore-III System and CPU Interfaces
Figure 101 • FDMA Channel Interrupt Hierarchy
EVT_ERR[ch]
OR
INTR_LLP[ch]
AND
AND
INTR_IDENT[ch]
INTR_LLP_ENA[ch]
INTR_FRM[ch]
AND
INTR_FRM_ENA[ch]
INTR_SIG[ch]
AND
INTR_SIG_ENA[ch]
Only for highest numbered extraction channel
INTR_XTR_SOF_RDY
AND
INTR_XTR_SOF_RDY_ENA
INTR_XTR_ANY_RDY
AND
INTR_XTR_SOF_ANY_ENA
Only for highest numbered injection channel
INTR_INJ_RDY
AND
INTR_INJ_RDY_ENA
INTR_ENA[ch]
5.7.5
FDMA Extraction
During extraction, the FDMA extracts Ethernet frame data from the Queuing System and saves it into the
data block of the DCB that is currently loaded by the FDMA extraction channel. The FDMA continually
processes DCBs until it reaches a DCB with LLP = NULL or until it is disabled.
When an extraction channel writes the status word of a DCB, it updates SOF/EOF/ABORT/PRUNEDindications and BLOCKL. BLOCKO remains unchanged (write value is taken from the value that was
read when the DCB was loaded).
Aborting frames from the queuing system will not occur during normal operation. If the queuing system is
reset during extraction of a particular frame, then ABORT and EOF is set. Software must discard frames
that have ABORT set.
Pruning of frames during extraction is enabled per extraction port through
XTR_FRM_PRUNING[group].PRUNE_SIZE. When enabled, Ethernet frames above the configured size
are truncated, and PD and EOF is set.
5.7.6
FDMA Injection
During injection, the FDMA reads Ethernet frame data from the data block of the DCB that is currently
loaded by the FDMA injection channel and injects this into the queuing system. The FDMA continually
processes DCBs until it reaches a DCB with LLP = NULL or until it is disabled.
When an injection channel writes the status word of a DCB, it sets DONE indication. All other status word
fields remain unchanged (write value is stored the first time the injection channel loads the DCB).
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
331
VCore-III System and CPU Interfaces
The rate by which the FDMA injects frames can be shaped by using tokens. Each injection channel has
an associated token counter (FDMA_CH_INJ_TOKEN_CNT[ich]). A DCB that has the DATAL.TOKEN
field set causes the injection channel to deduct one from the token counter before the data block of the
DCB can be injected. If the token counter is at 0, the injection channel postpones injection until the
channels token counter is set to a value different from 0.
Tokens can be added to the token counter by writing the FDMA_CH_INJ_TOKEN_CNT[ich] register.
Tokens can also be added automatically (with a fixed interval) by using the dedicated token tick counter.
Setting FDMA_CH_INJ_TOKEN_TICK_RLD[ich] to a value n (different from 0) will cause one token to be
added to that injection channel every n x 200 ns.
5.7.7
Manual Mode
The decision making logic of the FDMA extraction path and/or injection paths can be disabled to give
control of the FDMA’s extraction and/or injection buffers directly to any master attached to the Shared
Bus Architecture. When operating in manual mode DCB structure, counters and most of the interrupts do
not apply.
Manual extraction and injection use hard-coded channel numbers.
•
•
Manual extraction mode uses FDMA channel 1 (port 54 extraction direction).
Manual injection mode uses FDMA channel 9 (port 54 injection direction).
To enable manual extraction, set MANUAL_CFG.XTR_ENA. The FDMA must not be enabled for FDMA
extraction when manual extraction mode is active. To enable manual injection, set
MANUAL_CFG.INJ_ENA and FDMA_CH_CFG[9].CH_INJ_GRP = 1. The FDMA must not be enabled
for FDMA injection when manual injection mode is active. Extraction and injection paths are independent.
For example, FDMA can control extraction at the same time as doing manual injection by means of the
CPU.
5.7.7.1
Manual Extraction
Extraction is done by reading one or more blocks of data from the extraction memory area. A block of
data is defined by reading one or more data words followed by reading of the extraction status word. The
extraction memory area is 16 kilobytes and is implemented as a replicated register region
MANUAL_XTR. The highest register in the replication (0xFFF) maps to the extraction status word. The
status word is updated by the extraction logic and shows the number of frame bytes read, SOF and EOF
indications, and PRUNED/ABORT indications.
Note: During frame extraction, the CPU does not know the frame length. This means that the CPU must check
for EOF regularly during frame extraction. When reading a data block from the devices, the CPU can
burst read from the memory area in such a way that the extraction status word is read as the last word of
the burst.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
332
VCore-III System and CPU Interfaces
Figure 102 • Extraction Status Word Encoding
SOF
[31:20]
EOF
ABORT
PD
BLOCKO
191817 16
BLOCKL
[15:0]
BLOCKL: The amount of frame data (bytes) that
has been read in this block. The CPU might have
read more data than this, only valid frame data
(including Extraction Header) is counted here.
SOF: Start of frame, set if this block contains
start of a frame.
EOF: End of frame, set if this block contains end
of a frame.
ABORT: Set if this frame has been aborted by
the Queuing System. Write Ҭ to discard the
remainder of the active frame.
PD: Pruned indication, set if the frame has been
pruned to less than original length.
BLOCKO: The amount of dummy bytes (non-frame
data) read before start of frame data.
The extraction logic updates the extraction status word while the CPU is reading out data for a block.
Prior to starting a new data block, the CPU can write the two least significant bits of the BLOCKO field.
The BLOCKO value is stored in the extraction logic and takes effect when the new data block is started.
Reading the status field always returns the BLOCKO value that applies to the current data block. Unless
written (before stating a data block), the BLOCKO is cleared, so by default all blocks have 0 byte offset.
The offset can be written multiple times; the last value takes effect.
The CPU can abort frames that it has already started to read out by writing the extraction status field with
the ABORT field set. All other status-word fields will be ignored. This causes the extraction logic to
discard the active frame and remove it from the queuing system.
Reading of block data does not have to be done in one burst. As long as the status word is not read,
multiple reads from the extraction region are treated as belonging to the same block.
5.7.7.2
Manual Injection
Injection is done by writing one or more blocks of data to the injection memory area. A block of data is
defined by writing an injection status word followed by writing one or more data words. The injection
memory area is 16 kilobytes and is implemented as a replicated register region MANUAL_INJ. The first
register in this replication maps to the injection status word. The status word for each block defines the
following:
•
Number of bytes to be injected
•
Optional byte offset before injection data
•
SOF and EOF indications
•
Optional ABORT indication
Note: In general, it makes sense to inject frames as a single large block of data (containing both SOF and
EOF). However, because offset/length can be specified individually for each block, injecting frames
through several blocks is useful when compensating for offset/word misalignment. For example, when
building a frame from different memory regions in the CPU main memory.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
333
VCore-III System and CPU Interfaces
Figure 103 • Injection Status Word Encoding
SOF
[31:20]
EOF
ABORT
PD
BLOCKO
19 18 17 16
BLOCKL
[15:0]
BLOCKL: The amount of frame data (bytes) that
will be written for this block. The CPU is allowed to
write more data than this, additional data will be
ignored.
SOF: Start of frame, set to indicate that this block
contains start of a frame.
EOF: End of frame, set to indicate that this block
contains end of a frame.
ABORT: Set to abort active frame transfer. The
current frame will be aborted and removed from
Queuing System.
PD: Injection done, is set by the injection logic
when enough data has been received for this block
of data (BLOCKO+BLOCKL). If set when writing
status word, then this is treated as if ABORT had
been set.
BLOCKO: The amount of dummy bytes (non-frame
data) to expect before the frame data. The dummy
data will be ignored.
Injection logic updates the PD field of the status word. The status word can be read at any time during
injection without affecting current data block transfers. However, a CPU is able to calculate how much
data that is required to inject a complete block of data (at least BLOCKO + BLOCKL bytes), so reading
the status word is for software development and debug only. Writing status word before finishing a
previous data block will cause that frame to be aborted. Frames are also aborted if they do not start with
SOF or end with EOF indications.
As long as the status word is not written, multiple writes to the injection region are treated as data
belonging to the same block. This means multiple bursts of data words can be written between each
injection status word update.
Software can abort frames by writing to injection status with ABORT field set. All other status word fields
are ignored. When a frame is aborted, the already injected data is removed from the queuing system.
5.8
VCore-III System Peripherals
This section describes the subblocks of the VCore-III system. Although the subblocks are primarily
intended to be used by the VCore-III CPU, an external CPU can also access and control them through
the shared bus.
5.8.1
SI Boot Controller
The SPI boot master allows booting from a Flash that is connected to the serial interface. For information
about how to write to the serial interface, see SI Master Controller, page 336. For information about using
an external CPU to access device registers using the serial interface, see Serial Interface in Slave Mode,
page 313.
The following table lists the registers associated with the SI boot controller.
Table 255 • SI Boot Controller Configuration Registers
Register
Description
ICPU_CFG::SPI_MST_CFG
Serial interface speed and address width
ICPU_CFG::SW_MODE
Legacy manual control of the serial interface pins
ICPU_CFG::GENERAL_CTRL
SI interface ownership
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
334
VCore-III System and CPU Interfaces
By default, the SI boot controller operates in 24-bit address mode. In this mode, there are four
programmable chip selects when the VCore-III system controls the SI. Each chip select can address up
to 16 megabytes (MB) of memory.
Figure 104 • SI Boot Controller Memory Map in 24-Bit Mode
SI Controller
+0x01000000
+0x02000000
+0x03000000
SI Controller Memory Map
16 MB
Chip Select 0, SI_nCS0
16 MB
Chip Select 1, SI_nCS1
16 MB
Chip Select 2, SI_nCS2
16 MB
Chip Select 3, SI_nCS3
The SI boot controller can be reconfigured for 32-bit address mode through SPI_MST_CFG.A32B_ENA.
In 32-bit mode, the entire SI region of 256 megabytes (MB) is addressed using chip select 0.
Figure 105 • SI Boot Controller Memory Map in 32-Bit Mode
SI Controller
SI Controller Memory Map (32- bit)
256 MB
Chip Select 0, SI_nCS0
Reading from the memory region for a specific SI chip select generates an SI read on that chip select.
The VCore-III CPU can execute code directly from Flash by executing from the SI boot controller’s
memory region. For 32-bit capable SI Flash devices, the VCore-III must start up in 24-bit mode. During
the boot process, it must manually reconfigure the Flash device (and SI boot controller) into 32-bit mode
and then continue booting.
The SI boot controller accepts 8-bit, 16-bit, and 32-bit read access with or without bursting. Writing to the
SI requires manual control of the SI pins using software. Setting SW_MODE.SW_PIN_CTRL_MODE
places all SI pins under software control. Output enable and the value of SI_CLK, SI_DO, SI_nCSn are
controlled through the SW_MODE register. The value of the SI_DI pin is available in
SW_MODE.SW_SPI_SDI. The software control mode is provided for legacy reasons; new
implementations should use the dedicated master controller for writing to the serial interface. For more
information see SI Master Controller, page 336.
Note: The VCore-III CPU cannot execute code directly from the SI boot controller’s memory region at the same
time as manually writing to the serial interface.
The following table lists the serial interface pins when the SI boot controller is configured as owner of SI
interface in GENERAL_CTRL.IF_SI_OWNER. For more information about overlaid functions on the
GPIOs for these signals, see GPIO Overlaid Functions, page 354.
Table 256 • Serial Interface Pins
Pin Name
I/O
Description
SI_nCS0
SI_nCS[3:1]/GPIO
O
Active low chip selects. Only one chip select can be active at any
time. Chip selects 1 through 3 are overlaid functions on GPIO pins.
SI_CLK
O
Clock output.
SI_DO
O
Data output (MOSI).
SI_DI
I
Data input (MISO).
The SI boot controller does speculative prefetching of data. After reading address n, the SI boot
controller automatically continues reading address n + 1, so that the next value is ready if requested by
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
335
VCore-III System and CPU Interfaces
the VCore-III CPU. This greatly optimizes reading from sequential addresses in the Flash, such as when
copying data from Flash into program memory.
The following illustrations depict 24-bit address mode. When the controller is set to 32-bit mode (through
SPI_MST_CFG.A32B_ENA), 32 address bits are transferred instead of 24.
Figure 106 • SI Read Timing in Normal Mode
SI_nCS0
SI_CLK
2 2 2 2 1 1 1 1 1 1 1 1 1 1
9 8 7 6 5 4 3 2 1 0
3 2 1 0 9 8 7 6 5 4 3 2 1 0
SI_DO
READ
24 Bit Address
SI_DI
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Data Byte #0
Data Byte #1
Data Byte #2
Data Byte #3
Figure 107 • SI Read Timing in Fast Mode
SI_nCS0
SI_CLK
2 2 2 2 1 1 1 1 1 1 1 1 1 1
9 8 7 6 5 4 3 2 1 0
3 2 1 0 9 8 7 6 5 4 3 2 1 0
SI_DO
FAST_READ
24 Bit Address
SI_DI
Dummy Byte
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Data Byte #0
Data Byte #1
Data Byte #2
Data Byte #3
The default timing of the SI boot controller operates with most serial interface Flash devices. Use the
following process to calculate the optimized serial interface parameters for a specific SI device:
1.
2.
3.
Calculate an appropriate frequency divider value as described in SPI_MST_CFG.CLK_DIV. The SI
operates at no more than 25 MHz, and the maximum frequency of the SPI device must not be
exceeded. The VCore-III system frequency in the devices is 250 MHz.
The SPI device may require a FAST_READ command rather than normal READ when the SI
frequency is increased. Setting SPI_MST_CFG.FAST_READ_ENA makes the SI boot controller use
FAST_READ commands.
Calculate SPI_MST_CFG.CS_DESELECT_TIME so that it matches how long the SPI device
requires chip-select to be deasserted between access. This value depends on the SI clock period
that results from the SPI_MST_CFG.CLK_DIV setting.
These parameters must be written to SPI_MST_CFG. The CLK_DIV field must either be written last or at
the same time as the other parameters. The SPI_MST_CFG register can be configured while also
booting up from the SI.
When the VCore-III CPU boots from the SI interface, the default values of the SPI_MST_CFG register
are used until the SI_MST_CFG is reconfigured with optimized parameters. This implies that SI_CLK is
operating at approximately 8.1 MHz, with normal read instructions and maximum gap between chip
select operations to the Flash.
Note: The SPI boot master does optimized reading. SI_DI (from the Flash) is sampled just before driving falling
edge on SI_CLK (to the Flash). This greatly relaxes the round trip delay requirement for SI_CLK to SI_DI,
allowing high Flash clock frequencies.
5.8.2
SI Master Controller
This section describes the SPI master controller (SIMC) and how to use it for accessing external SPI
slave devices, such as programming of a serially attached Flash device on the boot interface. VCore
booting from serial Flash is handled by the SI boot master.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
336
VCore-III System and CPU Interfaces
The following table lists the registers associated with the SI master controller.
Table 257 • SI Master Controller Configuration Registers Overview
Register
Description
SIMC::CTRLR0
Transaction configuration
SIMC::CTRLR1
Configurations for receive-only mode
SIMC::SIMCEN
SI master controller enable
SIMC::SER
Slave select configuration
SIMC::BAUDR
Baud rate configuration
SIMC::TXFTLR
Tx FIFO threshold level
SIMC::RXFTLR
Rx FIFO Threshold Level
SIMC::TXFLR
Tx FIFO fill level
SIMC::RXFLR
Rx FIFO fill level
SIMC::SR
Various status indications
SIMC::IMR
Interrupt enable
SIMC::ISR
Interrupt sources
SIMC::RISR
Unmasked interrupt sources
SIMC::TXOICR
Clear of transmit FIFO overflow interrupt
SIMC::RXOICR
Clear of receive FIFO overflow interrupt
SIMC::RXUICR
Clear of receive FIFO underflow interrupt
SIMC::DR
Tx/Rx FIFO access
ICPU_CFG::GENERAL_CTRL
Interface configurations
The SI master controller supports Motorola SPI and Texas Instruments SSP protocols. The default
protocol is SPI, enable SSP by setting CTRLR0.FRF = 1 and GENERAL_CTRL.SSP_MODE_ENA = 1.
The protocol baud rate is programmable in BAUDR.SCKDV; the maximum baud rate is 25 MHz.
Before the SI master controller can be used, it must be set as owner of the serial interface. This is done
by writing GENERAL_CTRL.IF_SI_OWNER = 2.
The SI master controller has a programmable frame size. The frame size is the smallest unit when
transferring data over the SI interface. Using CTRLR0.DFS, the frame size is configured in the range of 4
bits to 16 bits. When reading or writing words from the transmit/receive FIFO, the number of bits that is
stored per FIFO-word is always equal to frame size (as programmed in CTRLR0.DFS).
The controller operates in one of three following major modes: Transmit and receive, transmit only, or
receive only. The mode is configured in CTRLR0.TMOD.
Transmit and receive. software paces SI transactions. For every data frame that software writes to the
transmission FIFO, another data frame is made available in the receive FIFO (receive data from the
serial interface). Transaction will go on for as long as there is data available in the transmission FIFO.
Transmit only. Software paces SI transactions. The controller transmits only; receive data is discarded.
Transaction will go on for as long as there is data available in the transmission FIFO.
Receive only. The controller paces SI transactions. The controller receives only data, software requests
a specific number of data frames by means of CTRLR1.NDF, the transaction will go on until all data
frames has been read from the SI interface. Transaction is initiated by software writing one data frame to
transmission FIFO. This frame is not used for anything else than starting the transaction. The SI_DO
output is undefined during receive only transfers. Receive data frames are put into the receive FIFO as
they are read from SI.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
337
VCore-III System and CPU Interfaces
For SPI mode, chip select is asserted throughout transfers. Transmit transfers end when the transmit
FIFO runs out of data frames. Software must make sure it is not interrupted while writing data for a
multiframe transfer. When multiple distinct transfers are needed, wait for SR.TFE = 1 and SR.BUSY = 0
before initiating new transfer. SR.BUSY is an indication of ongoing transfers, however, it is not asserted
immediately when writing frames to the FIFO. As a result, software must also check the SR.TFE
(transmit FIFO empty) indication.
The SI master controller supports up to 16 chip selects. Chip select 0 is mapped to the SI_nCS pin of the
serial interface. The remaining chips selects are available using overlaid GPIO functions. Software
controls which chip selects to activate for a transfer using the SER register. For more information about
overlaid functions on the GPIOs for these signals, see GPIO Overlaid Functions, page 354.
Table 258 • SI Master Controller Pins
Pin Name
I/O
Description
SI_nCS0
SI_nCS[15:1]/GPIO
O
Active low chip selects. Chip selects 1 through
15 are overlaid functions on the GPIO pins.
SI_CLK
O
Clock output.
SI_DO
O
Data output (MOSI).
SI_DI
I
Data input (MISO).
Writing to any DR replication index put data into the transmission FIFO, and reading from any DR
replication index take out data from the receive FIFO. FIFO status indications are available in the SR
register’s TFE, TFNF, RFF, and RFNE fields. For information about interrupting on FIFO status, see
SIMC Interrupts, page 340.
After completing all initial configurations, the SI master controller is enabled by writing
SIMCEN.SIMCEN = 1. Some registers can only be written when the controller is in disabled state. This is
noted in the register-descriptions for the affected registers.
5.8.2.1
SPI Protocol
When the SI master controller is configured for SPI mode, clock polarity and position is configurable in
CTRLR0.SCPH and CTRLR0.SCPOL. The following illustration shows the four possible combinations for
8-bit transfers.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
338
VCore-III System and CPU Interfaces
Figure 108 • SIMC SPI Clock Configurations
SI_nCS0
SI_nCS0
SI_CLK
SI_CLK
SI_DO
7
6
5
4
3
2
1
0
SI_DO
7
6
5
4
3
2
1
0
SI_DI
7
6
5
4
3
2
1
0
SI_DI
7
6
5
4
3
2
1
0
CTRLR0.SCPH = 0, CTRLR0.SCPOL = 0
CTRLR0.SCPH = 0, CTRLR0.SCPOL = 1
SI_nCS0
SI_nCS0
SI_CLK
SI_CLK
SI_DO
7
6
5
4
3
2
1
0
SI_DO
7
6
5
4
3
2
1
0
SI_DI
7
6
5
4
3
2
1
0
SI_DI
7
6
5
4
3
2
1
0
CTRLR0.SCPH = 1, CTRLR0.SCPOL = 0
CTRLR0.SCPH = 1, CTRLR0.SCPOL = 1
Data is sampled in the middle of the data-eye.
When using SPI protocol and transferring more than one data frame at the time, the controller performs
one consecutive transfer. The following illustration shows a transfer of three data frames of 4 bits each.
Note: Transmitting transfers end when the transmit FIFO runs out of data frames. Receive only transfers end
when the pre-defined number of data-frames is read from the SI interface.
Figure 109 • SIMC SPI 3x Transfers
SI_nCS0
SI_CLK
SI_DO
3
2
1
0
3
2
1
0
3
2
1
0
SI_DI
3
2
1
0
3
2
1
0
3
2
1
0
First frame
5.8.2.2
Second frame
Third frame
SSP Protocol
The SSP protocol for transferring two 6-bit data frames is shown in the following illustration. When using
SSP mode, CTRLR0.SCPH and CTRLR0.SCPOL must remain zero.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
339
VCore-III System and CPU Interfaces
5.8.2.3
SIMC SSP 2x Transfers
SI_nCS0
SI_CLK
SI_DO
5
4
3
2
1
0
5
4
3
2
1
0
SI_DI
5
4
3
2
1
0
5
4
3
2
1
0
First frame
5.8.2.4
Second frame
SIMC Interrupts
The SI master controller has five interrupt sources:
•
•
•
•
•
RXF interrupt is asserted when the fill level of the receive FIFO (available in RXFLR) exceeds the
programmable level set in RXFTLR. This interrupt is non-sticky; it is deasserted when fill level is
decreased below the programmable level.
RXO interrupt is asserted on receive FIFO overflow. This interrupt is cleared by reading the RXOICR
register.
RXU interrupt is asserted when reading from an empty receive FIFO. This interrupt is cleared by
reading the RXUICR register.
TXO interrupt is asserted when writing to a full transmit FIFO. This interrupt is cleared by reading the
TXOICR register.
TXE interrupt is asserted when the fill level of the transmit FIFO (available in TXFLR) is below the
programmable level set in TXFTLR. This interrupt is non-sticky; it is deasserted when fill level is
increased above the programmable level.
The raw (unmasked) status of these interrupts is available in the RISR register. Each of the interrupts can
be individually masked by the IMR register. All interrupts are enabled by default. The currently active
interrupts are shown in the ISR register.
If the RXO, RXU, and TXO interrupts occur during normal use of the SI master controller, it is an
indication of software problems.
Interrupt is asserted towards the VCore-III interrupt controller when any enabled interrupt is asserted and
the SI master controller is enabled.
5.8.2.5
SIMC Programming Example
This example shows how to use the SI master controller to interface with the SI slave of another
VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 device. The slave device will be initialized
for big endian/most significant bit first mode and then the DEVCPU_GCB::GPR register is written with
the value 0x01234567. It is assumed that the other device’s SI slave is connected on SI_nCS1 (and that
appropriate GPIO alternate function has been enabled).
The SI slave is using a 24-bit address field and a 32-bit data field. This example uses 4 x 16-bit data
frames to transfer the write-access. This means that 8 bits too much will be transferred, this is not a
problem for the Microsemi SI slave interface; it ignores data above and beyond the 56 bit required for a
write-access.
For information about initialization and how to calculate the 24-bit SI address field, see Serial Interface in
Slave Mode, page 313. The address-field when writing DEVCPU_GCB::GPR is 0x804001 (including
write-indication).
The following steps are required to bring up the SI master controller and write twice to the SI slave
device.
Important The following procedure disconnects the SI boot master from the SI interface. Booting must
be done before attempting to overtake the boot-interface.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
340
VCore-III System and CPU Interfaces
1.
2.
3.
4.
5.
6.
7.
8.
9.
Write GENERAL_CTRL.IF_SI_OWNER = 2 to make SI master controller the owner of the SI
interface.
Write BAUDR = 250 to get 1 MHz baud rate.
Write SER = 2 to use SI_nCS1.
Write CTRLR0 = 0x10F for 16-bit data frame and transmit only.
Write SIMCEN = 1 to enable the SI master controller.
Write DR[0] = 0x8000, 0x0081, 0x8181, 0x8100 to configure SI slave for big endian / most significant
bit first mode.
Wait for SR.TFE = 1 and SR.BUSY = 0 for chip select to deassert between accesses to the SI slave.
Write DR[0] = 0x8040, 0x0101, 0x2345, 0x6700 to write DEVCPU_GCB::GPR in slave device.
Wait for SR.TFE = 1 and SR.BUSY = 0, then disable the SI master controller by writing SIMCEN = 0.
When reading from the SI slave, CTRLR0.TMOD must be configured for transmit and receive. One-byte
padding is appropriate for a 1 MHz baud rate.
5.8.3
DDR3/DDR3L Memory Controller
This section provides information about how to configure and initialize the DDR3/DDR3L memory
controller.
The following table lists the registers associated with the memory controller.
Table 259 • DDR3/DDR3L Controller Registers
Register
Description
ICPU_CFG::RESET
Reset Control
ICPU_CFG::MEMCTRL_CTRL
Control
ICPU_CFG::MEMCTRL_CFG
Configuration
ICPU_CFG::MEMCTRL_STAT
Status
ICPU_CFG::MEMCTRL_REF_PERIOD
Refresh period configuration
ICPU_CFG::MEMCTRL_ZQCAL
DDR3/DDR3L ZQ-calibration
ICPU_CFG::MEMCTRL_TIMING0
Timing configuration
ICPU_CFG::MEMCTRL_TIMING1
Timing configuration
ICPU_CFG::MEMCTRL_TIMING2
Timing configuration
ICPU_CFG::MEMCTRL_TIMING3
Timing configuration
ICPU_CFG::MEMCTRL_MR0_VAL
Mode register 0 value
ICPU_CFG::MEMCTRL_MR1_VAL
Mode register 1 value
ICPU_CFG::MEMCTRL_MR2_VAL
Mode register 2 value
ICPU_CFG::MEMCTRL_MR3_VAL
Mode register 3 value
ICPU_CFG::MEMCTRL_TERMRES_CTRL
Termination resistor control
ICPU_CFG::MEMCTRL_DQS_DLY
DQS window configuration
ICPU_CFG::MEMPHY_CFG
SSTL configuration
ICPU_CFG::MEMPHY_ZCAL
SSTL calibration
The memory controller works with JEDEC-compliant DDR3/DDR3L memory modules. The controller
runs 312.50 MHz and supports one or two byte lanes in either single or dual row configurations (one or
two chip selects). The controller supports up to 16 address bits. The maximum amount of physical
memory that can be attached to the controller is 1 gigabyte.
The memory controller supports ECC encoding/decoding by using one of the two lanes for ECC
information. Enabling ECC requires that both byte lanes are populated. When ECC is enabled, half the
total physical memory is available for software use; the other half is used for ECC information.
VMDS-10498 VSC7442-02, VSC7444-02, VSC7448-02, and VSC7449-02 Datasheet Revision 4.1
341
VCore-III System and CPU Interfaces
The following steps are required to bring up the memory controller.
1.
2.
Release the controller from reset by clearing RESET.MEM_RST_FORCE.
Configure timing and mode parameters. These depend on the DDR3/DDR3L module and
configuration selected for the devices. For more information, see DDR3/DDR3L Timing and Mode
Configuration Parameters, page 342.
3. Enable and calibrate the SSTL I/Os. For more information, see Enabling and Calibrating SSTL I/Os.
4. Initialize the memory controller and modules. For more information, see Memory Controller and
Module Initialization.
5. Calibrate the DQS read window. For more information, see DQS Read Window Calibration.
6. Optionally configure ECC and 1 gigabyte support. For more information see ECC and 1 Gigabyte
Support.
Note: For selected DDR3/DDR3L modules, the bring-up of the memory controller is already implemented as
part of the Board Support Package (BSP). For more information about implementing the bring-up
procedure, see Microsemi eCos BSP and Tool Chain, which is available on the Microsemi Web site at
www.microsemi.com.
5.8.3.1
DDR3/DDR3L Timing and Mode Configuration Parameters
This section provides information about each of the parameters that must be configured prior to
initialization of the memory controller. It provides a quick overview of fields that must be configured and
their recommended values. For more information about each field, see the register list.
The memory controller operates at 312.5 MHz, and the corresponding DDR clock period is 3.2 ns
(DDR625). When a specific timing value is used in this section (for example, tMOD), it means that the
corresponding value from the memory module datasheet is expressed in memory controller clock cycles
(divided by 3.2 ns and rounded up and possibly adjusted for minimum clock cycle count).
The following table defines general parameters for DDR3/DDR3L required when configuring the memory
controller.
Table 260 • General DDR3/DDR3L Timing and Mode Parameters
Parameter
DDR3/DDR3L
RL
CL
WL
CWL
MD
tMOD
ID
tXPR
SD
tDLLK
OW
2
OR
2
RP
tRP
FAW
tFAW
BL
4
MR0
((RL-4)