0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
LTC2499CUHF#TRPBF

LTC2499CUHF#TRPBF

  • 厂商:

    AD(亚德诺)

  • 封装:

    WFQFN38

  • 描述:

    IC ADC 24BIT SIGMA-DELTA 38QFN

  • 数据手册
  • 价格&库存
LTC2499CUHF#TRPBF 数据手册
LTC2499 24-Bit 8-/16-Channel DS ADC with Easy Drive Input Current Cancellation and I2C Interface Description Features Up to Eight Differential or 16 Single-Ended Inputs n Easy Drive™ Technology Enables Rail-to-Rail Inputs with Zero Differential Input Current n Directly Digitizes High Impedance Sensors with Full Accuracy n 2-Wire I2C Interface with 27 Addresses Plus One Global Address for Synchronization n 600nV RMS Noise n Integrated High Accuracy Temperature Sensor n GND to V CC Input/Reference Common Mode Range n Programmable 50Hz, 60Hz or Simultaneous 50Hz/60Hz Rejection Mode n 2ppm INL, No Missing Codes n 1ppm Offset and 15ppm Full-Scale Error n 2x Speed/Reduced Power Mode (15Hz Using Internal Oscillator and 80µA at 7.5Hz Output) n No Latency: Digital Filter Settles in a Single Cycle, Even After a New Channel Is Selected n Single Supply 2.7V to 5.5V Operation (0.8mW) n Internal Oscillator n Tiny 5mm × 7mm QFN Package n Applications Direct Sensor Digitizer Direct Temperature Measurement n Instrumentation n Industrial Process Control n The LTC®2499 is a 16-channel (eight differential), 24-bit, No Latency ∆S™ ADC with Easy Drive technology and a 2-wire, I2C interface. The patented sampling scheme eliminates dynamic input current errors and the shortcomings of on-chip buffering through automatic cancellation of differential input current. This allows large external source impedances and rail-to-rail input signals to be directly digitized while maintaining exceptional DC accuracy. The LTC2499 includes a high accuracy, temperature sensor and an integrated oscillator. This device can be configured to measure an external signal (from combinations of 16 analog input channels operating in singleended or differential modes) or its internal temperature sensor. The integrated temperature sensor offers 1/30th°C resolution and 2°C absolute accuracy. The LTC2499 allows a wide common mode input range (0V to VCC), independent of the reference voltage. Any combination of single-ended or differential inputs can be selected and the first conversion, after a new channel is selected, is valid. Access to the multiplexer output enables optional external amplifiers to be shared between all analog inputs and auto calibration continuously removes their associated offset and drift. L, LT, LTC, LTM, Linear Technology and the Linear logo are registered trademarks and No Latency ∆∑ and Easy Drive are trademarks of Linear Technology Corporation. All other trademarks are the property of their respective owners. n Typical Application Integrated High Performance Temperature Sensor Data Acquisition System with Temperature Compensation 5 2.7V TO 5.5V TEMPERATURE SENSOR MUXOUT/ ADCIN VCC 10µF 0.1µF REF+ IN+ 24-BIT ∆Σ ADC WITH EASY DRIVE IN– MUXOUT/ ADCIN 1.7k SDA SCL REF– 2-WIRE I2C INTERFACE 3 ABSOLUTE ERROR (°C) CH0 CH1 • • • CH7 16-CHANNEL MUX CH8 • • • CH15 COM 4 fO OSC 2499 TA01 For more information www.linear.com/LTC2499 2 1 0 –1 –2 –3 –4 –5 –55 –30 –5 20 45 70 TEMPERATURE (°C) 95 120 2499 TA02 2499fe 1 LTC2499 Absolute Maximum Ratings Pin Configuration (Notes 1, 2) GND GND GND fO CA0 CA2 CA1 TOP VIEW Supply Voltage (VCC).................................... –0.3V to 6V Analog Input Voltage (CH0-CH15, COM).....................–0.3V to (VCC + 0.3V) REF +, REF –................................–0.3V to (VCC + 0.3V) ADCINN, ADCINP, MUXOUTP, MUXOUTN.................................–0.3V to (VCC + 0.3V) Digital Input Voltage.......................–0.3V to (VCC + 0.3V) Digital Output Voltage....................–0.3V to (VCC + 0.3V) Operating Temperature Range LTC2499C................................................. 0°C to 70°C LTC2499I..............................................–40°C to 85°C Storage Temperature Range....................–65°C to 150°C 38 37 36 35 34 33 32 GND 1 31 GND SCL 2 30 REF– SDA 3 29 REF+ GND 4 28 VCC 27 MUXOUTN NC 5 GND 6 26 ADCINN 39 COM 7 25 ADCINP CH0 8 24 MUXOUTP CH1 9 23 CH15 CH2 10 22 CH14 CH3 11 21 CH13 20 CH12 CH4 12 CH11 CH10 CH9 CH8 CH7 CH6 CH5 13 14 15 16 17 18 19 UHF PACKAGE 38-LEAD (5mm × 7mm) PLASTIC QFN TJMAX = 125°C, θJA = 34°C/W EXPOSED PAD (PIN #39) IS GND, MUST BE SOLDERED TO PCB order information LEAD FREE FINISH TAPE AND REEL PART MARKING* PACKAGE DESCRIPTION TEMPERATURE RANGE LTC2499CUHF#PBF LTC2499CUHF#TRPBF 2499 38-Lead (5mm × 7mm) Plastic QFN 0°C to 70°C LTC2499IUHF#PBF LTC2499IUHF#TRPBF 2499 38-Lead (5mm × 7mm) Plastic QFN –40°C to 85°C Consult LTC Marketing for parts specified with wider operating temperature ranges. *The temperature grade is identified by a label on the shipping container. Consult LTC Marketing for information on non-standard lead based finish parts. For more information on lead free part marking, go to: http://www.linear.com/leadfree/ For more information on tape and reel specifications, go to: http://www.linear.com/tapeandreel/ electrical characteristics (normal speed) The l denotes the specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25°C. (Notes 3, 4) PARAMETER CONDITIONS MIN Resolution (No Missing Codes) 0.1V ≤ VREF ≤ VCC, –FS ≤ VIN ≤ +FS (Note 5) Integral Nonlinearity 5V ≤ VCC ≤ 5.5V, VREF = 5V, VIN(CM) = 2.5V (Note 6) 2.7V ≤ VCC ≤ 5.5V, VREF = 2.5V, VIN(CM) = 1.25V (Note 6) Offset Error 2.5V ≤ VREF ≤ VCC, GND ≤ IN+ = IN– ≤ VCC (Note 13) , GND ≤ IN+ = IN– ≤ V Offset Error Drift 2.5V ≤ VREF ≤ VCC Positive Full-Scale Error 2.5V ≤ VREF ≤ VCC, IN+ = 0.75VREF , IN– = 0.25VREF Positive Full-Scale Error Drift 2.5V ≤ VREF ≤ VCC, IN+ = 0.75VREF , IN– = 0.25VREF Negative Full-Scale Error 2.5V ≤ VREF ≤ VCC, IN+ = 0.25VREF , IN– = 0.75VREF Negative Full-Scale Error Drift 2.5V ≤ VREF ≤ VCC, IN+ = 0.25VREF , IN– = 0.75VREF TYP MAX l l 2 1 10 ppm of VREF ppm of VREF l 0.5 2.5 µV 25 ppm of VREF 24 Bits 10 CC UNITS l nV/°C 0.1 ppm of VREF/°C 25 l 0.1 ppm of VREF ppm of VREF/°C 2499fe 2 For more information www.linear.com/LTC2499 LTC2499 Electrical Characteristics (Normal Speed) l denotes the specifications which The apply over the full operating temperature range, otherwise specifications are at TA = 25°C. (Notes 3, 4) PARAMETER CONDITIONS MIN Total Unadjusted Error 5V ≤ VCC ≤ 5.5V, VREF = 2.5V, VIN(CM) = 1.25V 5V ≤ VCC ≤ 5.5V, VREF = 5V, VIN(CM) = 2.5V 2.7V ≤ VCC ≤ 5.5V, VREF = 2.5V, VIN(CM) = 1.25V 15 15 15 ppm of VREF ppm of VREF ppm of VREF Output Noise 2.7V < VCC < 5.5V, 2.5V ≤ VREF ≤ VCC, GND ≤ IN+ = IN– ≤ VCC (Note 12) 0.6 µVRMS Internal PTAT Signal TA = 27°C (Note 13) 27.8 Internal PTAT Temperature Coefficient TYP 28.0 MAX UNITS 28.2 mV 93.5 µV/°C Electrical Characteristics (2x Speed) l denotes the specifications which apply over the The full operating temperature range, otherwise specifications are at TA = 25°C. (Notes 3, 4) PARAMETER CONDITIONS MIN Resolution (No Missing Codes) 0.1V ≤ VREF ≤ VCC, –FS ≤ VIN ≤ +FS (Note 5) Integral Nonlinearity 5V ≤ VCC ≤ 5.5V, VREF = 5V, VIN(CM) = 2.5V (Note 6) 2.7V ≤ VCC ≤ 5.5V, VREF = 2.5V, VIN(CM) = 1.25V (Note 6) Offset Error 2.5V ≤ VREF ≤ VCC, GND ≤ IN+ = IN– ≤ VCC (Note 13) Offset Error Drift 2.5V ≤ VREF ≤ VCC, GND ≤ IN+ = IN– ≤ VCC 2.5V ≤ VREF ≤ VCC, IN+ = 0.75VREF , IN– = 0.25VREF 2.5V ≤ VREF ≤ VCC, IN+ = 0.75VREF , IN– = 0.25VREF 2.5V ≤ VREF ≤ VCC, IN+ = 0.25VREF , IN– = 0.75VREF 2.5V ≤ VREF ≤ VCC, IN+ = 0.25VREF , IN– = 0.75VREF 5V ≤ VCC ≤ 5.5V, VREF = 5V, GND ≤ IN+ = IN– ≤ VCC Positive Full-Scale Error Positive Full-Scale Error Drift Negative Full-Scale Error Negative Full-Scale Error Drift Output Noise TYP MAX UNITS l 2 1 10 ppm of VREF ppm of VREF l 0.2 2 mV 25 ppm of VREF 24 Bits 100 nV/°C l 0.1 ppm of VREF/°C 25 l ppm of VREF 0.1 ppm of VREF/°C 0.85 µVRMS Converter Characteristics l denotes the specifications which apply over the full operating The temperature range, otherwise specifications are at TA = 25°C. (Note 3) PARAMETER CONDITIONS MIN , GND ≤ IN+ = IN– ≤ V Input Common Mode Rejection DC 2.5V ≤ VREF ≤ VCC Input Common Mode Rejection 50Hz ±2% 2.5V ≤ VREF ≤ VCC, GND ≤ IN+ = IN– ≤ VCC (Notes 5, 7) , GND ≤ IN+ = IN– ≤ V CC (Note 5) TYP MAX UNITS l 140 dB l 140 dB 140 Input Common Mode Rejection 60Hz ±2% 2.5V ≤ VREF ≤ VCC CC (Notes 5, 8) l Input Normal Mode Rejection 50Hz ±2% 2.5V ≤ VREF ≤ VCC, GND ≤ IN+ = IN– ≤ VCC (Notes 5, 7) l 110 120 dB 110 120 dB , GND ≤ IN+ = IN– ≤ V Input Normal Mode Rejection 60Hz ±2% 2.5V ≤ VREF ≤ VCC CC (Notes 5, 8) l Input Normal Mode Rejection 50Hz/60Hz ±2% 2.5V ≤ VREF ≤ VCC, GND ≤ IN+ = IN– ≤ VCC (Notes 5, 9) l 87 l 120 , GND ≤ IN+ = IN– ≤ V Reference Common Mode Rejection DC 2.5V ≤ VREF ≤ VCC Power Supply Rejection DC VREF = 2.5V, IN+ = IN– = GND Power Supply Rejection, 50Hz ±2%, 60Hz ±2% VREF CC (Note 5) = 2.5V, IN+ = IN– = GND (Notes 7, 8, 9) dB dB 140 dB 120 dB 120 dB Analog Input and Reference l denotes the specifications which apply over the full operating The temperature range, otherwise specifications are at TA = 25°C. (Note 3) SYMBOL PARAMETER IN+ Absolute/Common Mode IN+ Voltage (IN+ Corresponds to the Selected Positive Input Channel) CONDITIONS GND – 0.3V VCC + 0.3V V IN– Absolute/Common Mode IN– Voltage (IN– Corresponds to the Selected Negative Input Channel or COM) GND – 0.3V VCC + 0.3V V VIN Input Voltage Range (IN+ – IN–) –FS +FS V Differential/Single-Ended MIN l TYP MAX UNITS 2499fe For more information www.linear.com/LTC2499 3 LTC2499 Analog Input and Reference l denotes the specifications which apply over the full operating The temperature range, otherwise specifications are at TA = 25°C. (Note 3) FS Full Scale of the Input (IN+ – IN–) Differential/Single-Ended l 0.5VREF V LSB Least Significant Bit of the Output Code l FS/224 REF+ Absolute/Common Mode REF+ Voltage l 0.1 VCC V REF– Absolute/Common Mode REF– Voltage l GND REF+ – V VREF Reference Voltage Range (REF+ – REF–) l CS(IN+) IN+ Sampling Capacitance CS(IN–) IN– Sampling Capacitance 11 pF CS(VREF) VREF Sampling Capacitance 11 pF IDC_LEAK(IN+) IN+ DC Leakage Current Sleep Mode, IN+ = GND l –10 1 10 nA IDC_LEAK(IN–) IDC_LEAK(REF+) IDC_LEAK(REF–) IN– DC Leakage Current Sleep Mode, IN– = GND l –10 1 10 nA REF+ DC Leakage Current Sleep Mode, REF+ = V l –100 1 100 nA REF– DC Leakage Current Sleep Mode, REF– = GND l –100 1 100 nA tOPEN MUX Break-Before-Make QIRR MUX Off Isolation 0.1V 0.1 VCC V 11 CC VIN = 2VP-P DC to 1.8MHz pF 50 ns 120 dB 2C Inputs And Digital Outputs I The l denotes the specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25°C. (Note 3) SYMBOL PARAMETER VIH High Level Input Voltage CONDITIONS l MIN TYP MAX UNITS VIL Low Level Input Voltage l 0.3VCC V VIHA Low Level Input Voltage for Address Pins CA0, CA1, CA2 and Pin fO l 0.05VCC V 0.7VCC V VILA High Level Input Voltage for Address Pins CA0, CA1, CA2 l RINH Resistance from CA0, CA1, CA2 to VCC to Set Chip Address Bit to 1 l 10 kΩ RINL Resistance from CA0, CA1, CA2 to GND to Set Chip Address Bit to 0 l 10 kΩ RINF Resistance from CA0, CA1, CA2 to GND or VCC to Set Chip Address Bit to Float l 2 II Digital Input Current l –10 VHYS Hysteresis of Schmitt Trigger Inputs (Note 5) l 0.05VCC VOL Low Level Output Voltage (SDA) I = 3mA l tOF Output Fall Time VIH(MIN) to VIL(MAX) Bus Load CB 10pF to 400pF (Note 14) l IIN Input Leakage 0.1VCC ≤ VIN ≤ VCC CCAX External Capacitative Load on Chip Address Pins (CA0, CA1, CA2) for Valid Float 0.95VCC V MΩ 10 µA 0.4 V 250 ns l 1 µA l 10 pF V 20 + 0.1CB Power Requirements l denotes the specifications which apply over the full operating temperature The range, otherwise specifications are at TA = 25°C. (Note 3) SYMBOL PARAMETER VCC Supply Voltage ICC Supply Current CONDITIONS MIN l Conversion Current (Note 11) Temperature Measurement (Note 11) Sleep Mode (Note 11) l l l TYP 2.7 160 200 1 MAX UNITS 5.5 V 275 300 2 µA µA µA 2499fe 4 For more information www.linear.com/LTC2499 LTC2499 Digital Inputs And Digital Outputs l denotes the specifications which apply over the The full operating temperature range, otherwise specifications are at TA = 25°C. (Note 3) SYMBOL PARAMETER CONDITIONS (Note 16) MIN fEOSC External Oscillator Frequency Range tHEO External Oscillator High Period tLEO External Oscillator Low Period tCONV_1 Conversion Time for 1x Speed Mode 50Hz Mode 60Hz Mode Simultaneous 50Hz/60Hz Mode External Oscillator (Note 10) tCONV_2 Conversion Time for 2x Speed Mode 50Hz Mode 60Hz Mode Simultaneous 50Hz/60Hz Mode External Oscillator (Note 10) TYP MAX UNITS l 10 1000 kHz l 0.125 100 µs l 0.125 100 µs l l l 157.2 131 144.1 160.3 133.6 146.9 41036/fEOSC (in kHz) 163.5 136.3 149.9 ms ms ms ms l l l 78.7 65.6 72.2 80.3 66.9 73.6 81.9 68.2 75.1 ms ms ms ms 20556/fEOSC (in kHz) 2C TIMING CHARACTERISTICS I The l denotes the specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25°C. (Note 3, 15) SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS 400 kHz fSCL SCL Clock Frequency l 0 tHD(SDA) Hold Time (Repeated) START Condition l 0.6 µs tLOW LOW Period of the SCL Pin l 1.3 µs tHIGH HIGH Period of the SCL Pin l 0.6 µs tSU(STA) Set-Up Time for a Repeated START Condition l 0.6 tHD(DAT) Data Hold Time l 0 tSU(DAT) Data Set-Up Time l 100 tr Rise Time for SDA Signals (Note 14) l 20 + 0.1CB 300 tf Fall Time for SDA Signals (Note 14) l 20 + 0.1CB 300 tSU(STO) Set-Up Time for STOP Condition l 0.6 µs tBUF Bus Free Time Between a Second START Condition l 1.3 µs Note 1: Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. Exposure to any Absolute Maximum Rating condition for extended periods may affect device reliability and lifetime. Note 2: All voltage values are with respect to GND. Note 3: Unless otherwise specified: VCC = 2.7V to 5.5V VREFCM = VREF/2, FS = 0.5VREF VIN = IN+ – IN–, VIN(CM) = (IN+ – IN–)/2, where IN+ and IN– are the selected input channels. Note 4: Use internal conversion clock or external conversion clock source with fEOSC = 307.2kHz unless otherwise specified. Note 5: Guaranteed by design, not subject to test. Note 6: Integral nonlinearity is defined as the deviation of a code from a straight line passing through the actual endpoints of the transfer curve. The deviation is measured from the center of the quantization band. µs 0.9 µs ns ns ns Note 7: 50Hz mode (internal oscillator) or fEOSC = 256kHz ±2% (external oscillator). Note 8: 60Hz mode (internal oscillator) or fEOSC = 307.2kHz ±2% (external oscillator). Note 9: Simultaneous 50Hz/60Hz mode (internal oscillator) or fEOSC = 280kHz ±2% (external oscillator). Note 10: The external oscillator is connected to the fO pin. The external oscillator frequency, fEOSC, is expressed in kHz. Note 11: The converter uses its internal oscillator. Note 12: The output noise includes the contribution of the internal calibration operations. Note 13: Guaranteed by design and test correlation. Note 14: CB = capacitance of one bus line in pF (10pF ≤ CB ≤ 400pF). Note 15: All values refer to VIH(MIN) and VIL(MAX) levels. Note 16: Refer to Applications Information section for Performance vs Data Rate graphs. 2499fe For more information www.linear.com/LTC2499 5 LTC2499 Typical Performance Characteristics –45°C 25°C 0 85°C –1 3 VCC = 5V VREF = 2.5V VIN(CM) = 1.25V fO = GND 1 2 –45°C, 25°C, 85°C 0 –1 –3 –2.5 –2 –1.5 –1 –0.5 0 0.5 1 1.5 INPUT VOLTAGE (V) 2 –3 –1.25 2.5 –0.75 –0.25 0.25 0.75 INPUT VOLTAGE (V) Total Unadjusted Error (VCC = 5V, VREF = 5V) 25°C 4 0 12 –45°C –4 VCC = 5V VREF = 2.5V VIN(CM) = 1.25V fO = GND 85°C 8 –45°C 0 –4 2.5 –12 –1.25 –0.75 –0.25 0.25 0.75 INPUT VOLTAGE (V) –0.25 0.25 0.75 INPUT VOLTAGE (V) 1.25 2499 G03 Total Unadjusted Error (VCC = 2.7V, VREF = 2.5V) VCC = 2.7V VREF = 2.5V VIN(CM) = 1.25V fO = GND 25°C 4 85°C –45°C 0 –4 1.25 –12 –1.25 –0.75 –0.25 0.25 0.75 INPUT VOLTAGE (V) 1.25 2499 G06 2499 G05 Noise Histogram (6.8sps) Noise Histogram (7.5sps) 14 14 12 12 10,000 CONSECUTIVE READINGS RMS = 0.60µV VCC = 5V AVERAGE = –0.69µV VREF = 5V 10 VIN = 0V TA = 25°C NUMBER OF READINGS (%) NUMBER OF READINGS (%) –0.75 –8 2499 G04 8 6 4 2 0 –1 25°C –8 2 –45°C, 25°C, 85°C 0 12 4 –8 –12 –2.5 –2 –1.5 –1 –0.5 0 0.5 1 1.5 INPUT VOLTAGE (V) 1 –3 –1.25 1.25 Total Unadjusted Error (VCC = 5V, VREF = 2.5V) 8 85°C TUE (ppm of VREF) TUE (ppm of VREF) 8 VCC = 2.7V VREF = 2.5V VIN(CM) = 1.25V fO = GND 2499 G02 2499 G01 VCC = 5V VREF = 5V VIN(CM) = 2.5V fO = GND Integral Nonlinearity (VCC = 2.7V, VREF = 2.5V) –2 –2 –2 12 INL (ppm of VREF) INL (ppm of VREF) 1 2 Integral Nonlinearity (VCC = 5V, VREF = 2.5V) TUE (ppm of VREF) 2 3 VCC = 5V VREF = 5V VIN(CM) = 2.5V fO = GND INL (ppm of VREF) 3 Integral Nonlinearity (VCC = 5V, VREF = 5V) 10,000 CONSECUTIVE READINGS RMS = 0.59µV VCC = 2.7V AVERAGE = –0.19µV VREF = 2.5V 10 VIN = 0V TA = 25°C 8 6 4 2 –3 –2.4 –1.8 –1.2 –0.6 0 0.6 OUTPUT READING (µV) 1.2 1.8 0 –3 –2.4 –1.8 –1.2 –0.6 0 0.6 OUTPUT READING (µV) 2499 G07 1.2 1.8 2499 G08 2499fe 6 For more information www.linear.com/LTC2499 LTC2499 Typical Performance Characteristics RMS Noise vs Input Differential Voltage 5 TA = 25°C VCC = 5V VREF = 5V RMS NOISE = 0.60µV VIN = 0V VIN(CM) = 2.5V 4 3 2 1 0 –1 –2 –3 0.8 0 10 30 40 20 TIME (HOURS) 0.7 0.6 2499 G09 0.5 0.8 0.7 0.6 75 0.4 2.7 90 3.1 3.5 3.9 4.3 VCC (V) 4.7 5.1 2499 G12 0.1 0 5 4 6 RMS Noise vs VREF VCC = 5V VIN = 0V VIN(CM) = GND TA = 25°C fO = GND 0.8 0.7 0.6 0.4 5.5 0 1 2 3 VREF (V) 4 5 2499 G14 0.2 0.1 VCC = 5V VREF = 5V VIN = 0V VIN(CM) = GND fO = GND 0 –0.1 –0.1 –0.2 –0.3 3 2 VIN(CM) (V) Offset Error vs Temperature 0.3 VCC = 5V VREF = 5V VIN = 0V TA = 25°C fO = GND 0.2 1 2499 G13 Offset Error vs VIN(CM) 0.3 0 0.5 0.5 0 15 30 45 60 TEMPERATURE (°C) –1 0.9 OFFSET ERROR (ppm of VREF) 0.4 –45 –30 –15 1.0 VREF = 2.5V VIN = 0V VIN(CM) = GND TA = 25°C fO = GND 0.9 0.6 0.6 2499 G11 RMS Noise vs VCC 1.0 0.7 0.7 0.4 2.5 RMS NOISE (µV) 0.8 OFFSET ERROR (ppm of VREF) RMS NOISE (µV) 0.9 RMS Noise vs Temperature (TA) VCC = 5V VREF = 5V VIN = 0V VIN(CM) = GND fO = GND 0.8 2499 G10 RMS NOISE (µV) 1.0 VCC = 5V VREF = 5V VIN = 0V TA = 25°C fO = GND 0.5 0.4 –2.5 –2 –1.5 –1 –0.5 0 0.5 1 1.5 2 INPUT DIFFERENTIAL VOLTAGE (V) 60 50 RMS Noise vs VIN(CM) 0.9 0.5 –4 –5 1.0 VCC = 5V VREF = 5V VIN(CM) = 2.5V TA = 25°C fO = GND 0.9 RMS NOISE (µV) ADC READING (µV) 1.0 RMS NOISE (µV) Long-Term ADC Readings –0.2 –1 0 1 3 2 VIN(CM) (V) 4 5 6 –0.3 –45 –30 –15 2499 G15 0 15 30 45 60 TEMPERATURE (°C) 75 90 2499 G16 2499fe For more information www.linear.com/LTC2499 7 LTC2499 Typical Performance Characteristics 0.2 0.1 0.3 REF+ = 2.5V REF– = GND VIN = 0V VIN(CM) = GND TA = 25°C fO = GND OFFSET ERROR (ppm of VREF) OFFSET ERROR (ppm of VREF) 0.3 0 On-Chip Oscillator Frequency vs Temperature Offset Error vs VREF 0.2 0.1 –0.2 0 3.1 3.9 4.3 VCC (V) 3.5 4.7 5.1 –0.3 5.5 0 1 2 3 VREF (V) 302 2.5 3.0 3.5 4.0 VCC (V) 4.5 5.0 5.5 PSRR vs Frequency at VCC VCC = 4.1V DC VREF = 2.5V IN+ = GND IN– = GND fO = GND TA = 25°C –20 –40 –20 –40 –60 –80 –120 –120 10 10k 100k 1k 100 FREQUENCY AT VCC (Hz) CONVERSION CURRENT (µA) REJECTION (dB) 200 –60 –80 –100 –120 30700 0 20 40 60 80 100 120 140 160 180 200 220 FREQUENCY AT VCC (Hz) 2499 G22 Conversion Current vs Temperature VCC = 4.1V DC ±0.7V = 2.5V V –20 INREF + = GND – = GND IN –40 fO = GND TA = 25°C 30650 –140 2499 G21 PSRR vs Frequency at VCC –140 30600 1M VCC = 4.1V DC ±1.4V VREF = 2.5V IN+ = GND IN– = GND fO = GND TA = 25°C –80 –100 1 30750 FREQUENCY AT VCC (Hz) 90 –60 –100 –140 75 PSRR vs Frequency at VCC 0 2499 G20 0 0 15 30 45 60 TEMPERATURE (°C) 2499 G19 REJECTION (dB) 304 0 REJECTION (dB) FREQUENCY (kHz) 306 VCC = 4.1V VREF = 2.5V VIN = 0V VIN(CM) = GND fO = GND 2499 G18 On-Chip Oscillator Frequency vs VCC 308 304 300 –45 –30 –15 5 4 2499 G17 VREF = 2.5V VIN = 0V VIN(CM) = GND fO = GND TA = 25°C 306 302 –0.2 –0.3 2.7 300 308 –0.1 –0.1 310 310 VCC = 5V REF– = GND VIN = 0V VIN(CM) = GND TA = 25°C fO = GND FREQUENCY (kHz) Offset Error vs VCC 30800 fO = GND 180 VCC = 5V 160 140 VCC = 2.7V 120 100 –45 –30 –15 2499 G23 0 15 30 45 60 TEMPERATURE (°C) 75 90 2499 G24 2499fe 8 For more information www.linear.com/LTC2499 LTC2499 Typical Performance Characteristics Sleep Mode Current vs Temperature 500 fO = GND 1.6 1.4 1.2 VCC = 5V 1.0 0.8 0.6 VCC = 2.7V VCC = 5V –1 100 90 VCC = 3V 10 20 OUTPUT DATA RATE (READINGS/SEC) 0 2499 G25 3 VCC = 5V VREF = 2.5V VIN(CM) = 1.25V fO = GND 1 2 85°C 0 –1 –45°C, 25°C –2 16 85°C 0 –45°C, 25°C –1 –2 –0.75 –0.25 0.25 0.75 INPUT VOLTAGE (V) 1.25 –3 –1.25 –0.75 4 181.4 183.8 186.2 OUTPUT READING (µV) 188.6 2499 G30 Offset Error vs VIN(CM) (2x Speed Mode) 200 198 196 0.8 0.6 0.4 VCC = 5V VIN = 0V VIN(CM) = GND fO = GND TA = 25°C 1 6 2499 G29 1.0 0 8 0 179 1.25 –0.25 0.25 0.75 INPUT VOLTAGE (V) RMS Noise vs VREF (2x Speed Mode) 0 RMS = 0.85µV 10,000 CONSECUTIVE AVERAGE = 0.184mV 14 READINGS VCC = 5V 12 VREF = 5V VIN = 0V T = 25°C 10 A 2 2499 G28 0.2 2.5 Noise Histogram (2x Speed Mode) VCC = 2.7V VREF = 2.5V VIN(CM) = 1.25V fO = GND OFFSET ERROR (µV) –3 –1.25 Integral Nonlinearity (2x Speed Mode; VCC = 2.7V, VREF = 2.5V) 1 2 2499 G27 NUMBER OF READINGS (%) Integral Nonlinearity (2x Speed Mode; VCC = 5V, VREF = 2.5V) RMS NOISE (µV) INL (ppm OF VREF) 2 –3 –2.5 –2 –1.5 –1 –0.5 0 0.5 1 1.5 INPUT VOLTAGE (V) 30 2499 G26 INL (ppm OF VREF) 3 –45°C –2 150 75 25°C, 90°C 0 200 0.2 0 15 30 45 60 TEMPERATURE (°C) VCC = 5V VREF = 5V VIN(CM) = 2.5V fO = GND 1 300 250 Integral Nonlinearity (2x Speed Mode; VCC = 5V, VREF = 5V) 2 350 0.4 0 –45 –30 –15 3 VREF = VCC + 450 IN– = GND IN = GND 400 fO = EXT OSC TA = 25°C SUPPLY CURRENT (µA) SLEEP MODE CURRENT (µA) 1.8 INL (µV) 2.0 Conversion Current vs Output Data Rate 194 VCC = 5V VREF = 5V VIN = 0V fO = GND TA = 25°C 192 190 188 186 184 182 3 2 VREF (V) 4 5 180 –1 2499 G31 0 1 3 2 VIN(CM) (V) 4 5 6 2499 G32 2499fe For more information www.linear.com/LTC2499 9 LTC2499 Typical Performance Characteristics 240 220 210 200 190 180 240 VREF = 2.5V VIN = 0V VIN(CM) = GND fO = GND TA = 25°C 200 OFFSET ERROR (µV) 230 OFFSET ERROR (µV) 250 VCC = 5V VREF = 5V VIN = 0V VIN(CM) = GND fO = GND Offset Error vs VCC (2x Speed Mode) 150 100 0 15 30 45 60 TEMPERATURE (°C) 75 0 90 2 2.5 3 4 3.5 VCC (V) 4.5 210 200 190 –20 RREJECTION (dB) –60 –80 –100 –120 1 10 10k 100k 1k 100 FREQUENCY AT VCC (Hz) 1M 0 1 2 3 VREF (V) 4 –40 –60 0 VCC = 4.1V DC ±1.4V REF+ = 2.5V REF– = GND IN+ = GND IN– = GND fO = GND TA = 25°C VCC = 4.1V DC ±0.7V REF+ = 2.5V REF– = GND IN+ = GND –40 IN– = GND fO = GND –60 TA = 25°C –80 –100 –100 –120 –120 0 20 40 60 80 100 120 140 160 180 200 220 FREQUENCY AT VCC (Hz) 2499 G36 PSRR vs Frequency at VCC (2x Speed Mode) –20 –80 –140 5 2499 G35 REJECTION (dB) 0 VCC = 4.1V DC REF+ = 2.5V REF– = GND IN+ = GND IN– = GND fO = GND TA = 25°C –40 160 5.5 PSRR vs Frequency at VCC (2x Speed Mode) PSRR vs Frequency at VCC (2x Speed Mode) –20 5 2499 G34 2499 G33 REJECTION (dB) 220 170 160 –45 –30 –15 –140 VCC = 5V VIN = 0V VIN(CM) = GND fO = GND TA = 25°C 180 50 170 0 Offset Error vs VREF (2x Speed Mode) 230 OFFSET ERROR (µV) Offset Error vs Temperature (2x Speed Mode) 2499 G37 –140 30600 30650 30700 30750 FREQUENCY AT VCC (Hz) 30800 2499 G38 pin functions GND (Pins 1, 4, 6, 31, 32, 33, 34): Ground. Multiple ground pins internally connected for optimum ground current flow and VCC decoupling. Connect each one of these pins to a common ground plane through a low impedance connection. All seven pins must be connected to ground for proper operation. SCL (Pin 2): Serial Clock Pin of the I2C Interface. The LTC2499 can only act as a slave and the SCL pin only accepts an external serial clock. Data is shifted into the SDA pin on the rising edges of the SCL clock and output through the SDA pin on the falling edges of the SCL clock. SDA (Pin 3): Bidirectional Serial Data Line of the I2C Interface. In the transmitter mode (read), the conversion result is output through the SDA pin, while in the receiver mode (write), the device channel select and configuration bits are input through the SDA pin. The pin is high impedance during the data input mode and is an open drain output (requires an appropriate pull-up device to VCC) during the data output mode. NC (Pin 5): No Connect. This pin can be left floating or tied to GND. 2499fe 10 For more information www.linear.com/LTC2499 LTC2499 pin functions COM (Pin 7): The Common Negative Input (IN –) for All Single-Ended Multiplexer Configurations. The voltage on CH0-CH15 and COM pins can have any value between GND – 0.3V to VCC + 0.3V. Within these limits, the two selected inputs (IN+ and IN– ) provide a bipolar input range (VIN = IN+ – IN– ) from –0.5 • VREF to 0.5 • VREF . Outside this input range, the converter produces unique overrange and underrange output codes. REF+, REF – (Pin 29, Pin 30): Differential Reference Input. The voltage on these pins can have any value between GND and VCC as long as the reference positive input, REF+, remains more positive than the negative reference input, REF–, by at least 0.1V. The differential voltage (VREF = REF+ – REF –) sets the full-scale range for all input channels. When performing an on-chip measurement, the minimum value of REF = 2V. CH0 to CH15 (Pin 8-Pin 23): Analog Inputs. May be programmed for single-ended or differential mode. fO (Pin 35): Frequency Control Pin. Digital input that controls the internal conversion clock rate. When fO is connected to GND, the converter uses its internal oscillator running at 307.2kHz. The conversion clock may also be overridden by driving the fO pin with an external clock in order to change the output rate and the digital filter rejection null. MUXOUTP (Pin 24): Positive Multiplexer Output. Connect to the input of external buffer/amplifier or short directly to ADCINP. ADCINP (Pin 25): Positive ADC Input. Connect to the output of a buffer/amplifier driven by MUXOUTP or short directly to MUXOUTP. ADCINN (Pin 26): Negative ADC Input. Connect to the output of a buffer/amplifier driven by MUXOUTN or short directly to MUXOUTN MUXOUTN (Pin 27): Negative Multiplexer Output. Connect to the input of an external buffer/amplifier or short directly to ADCINN. CA0, CA1, CA2 (Pins 36, 37, 38): Chip Address Control Pins. These pins are configured as a three-state (LOW, HIGH, floating) address control bits for the device I2C address. Exposed Pad (Pin 39): Ground. This pin is ground and must be soldered to the PCB ground plane. For prototyping purposes, this pin may remain floating. VCC (Pin 28): Positive Supply Voltage. Bypass to GND with a 10µF tantalum capacitor in parallel with a 0.1µF ceramic capacitor as close to the part as possible. functional block diagram TEMP SENSOR VCC GND INTERNAL OSCILLATOR CH0 CH1 CH15 COM – • • • + DIFFERENTIAL 3RD ORDER ∆Σ MODULATOR MUX fO (INT/EXT) AUTOCALIBRATION AND CONTROL MUXOUTP ADCINP REF+ REF– I2C 2-WIRE INTERFACE SDA SCL DECIMATING FIR ADDRESS 2499 BD MUXOUTN ADCINN 2499fe For more information www.linear.com/LTC2499 11 LTC2499 Applications Information CONVERTER OPERATION POWER-ON RESET DEFAULT CONFIGURATION: IN+ = CH0, IN– = CH1 50Hz/60Hz REJECTION 1x OUTPUT Converter Operation Cycle The LTC2499 is a multichannel, low power, delta-sigma analog-to-digital converter with a 2-wire, I2C interface. Its operation is made up of four states (see Figure 1). The converter operating cycle begins with the conversion, followed by the sleep state and ends with the data input/ output cycle . CONVERSION SLEEP Initially, at power-up, the LTC2499 performs a conversion. Once the conversion is complete, the device enters the sleep state. While in the sleep state, power consumption is reduced by two orders of magnitude. The part remains in the sleep state as long it is not addressed for a read/ write operation. The conversion result is held indefinitely in a static shift register while the part is in the sleep state. The device will not acknowledge an external request during the conversion state. After a conversion is finished, the device is ready to accept a read/write request. Once the LTC2499 is addressed for a read operation, the device begins outputting the conversion result under the control of the serial clock (SCL). There is no latency in the conversion result. The data output is 32 bits long and contains a 24-bit plus sign conversion result. Data is updated on the falling edges of SCL allowing the user to reliably latch data on the rising edge of SCL. A new conversion is initiated by a STOP condition following a valid write operation or an incomplete read operation. The conversion automatically begins at the conclusion of a complete read cycle (all 32 bits read out of the device). Ease of Use The LTC2499 data output has no latency, filter settling delay, or redundant data associated with the conversion cycle. There is a one-to-one correspondence between the conversion and the output data. Therefore, multiplexing multiple analog inputs is straightforward. Each conversion, immediately following a newly selected input or mode, is valid and accurate to the full specifications of the device. The LTC2499 automatically performs offset and full-scale calibration every conversion cycle independent of the input channel selected. This calibration is transparent to the user and has no effect on the operation cycle described above. 12 NO ACKNOWLEDGE YES DATA OUTPUT/INPUT NO STOP OR READ 32 BITS YES 2499 F01 Figure 1. State Transition Table The advantage of continuous calibration is extreme stability of offset and full-scale readings with respect to time, supply voltage variation, input channel and temperature drift. Easy Drive Input Current Cancellation The LTC2499 combines a high precision, delta-sigma ADC with an automatic, differential, input current cancellation front end. A proprietary front-end passive sampling network transparently removes the differential input current. This enables external RC networks and high impedance sensors to directly interface to the LTC2499 without external amplifiers. The remaining common mode input current is eliminated by either balancing the differential input impedances or setting the common mode input equal to the common mode reference (see the Automatic Differential Input Current Cancellation section). This unique architecture does not require on-chip buffers, thereby enabling signals to swing beyond ground and VCC. Moreover, the cancellation does not interfere with the transparent offset For more information www.linear.com/LTC2499 2499fe LTC2499 Applications Information and full-scale auto-calibration and the absolute accuracy (full scale + offset + linearity + drift) is maintained even with external RC networks. Power-Up Sequence The LTC2499 automatically enters an internal reset state when the power supply voltage VCC drops below approximately 2.0V. This feature guarantees the integrity of the conversion result and input channel selection. When VCC rises above this threshold, the converter creates an internal power-on reset (POR) signal with a duration of approximately 4ms. The POR signal clears all internal registers. The conversion immediately following a POR cycle is performed on the input channel IN+ = CH0, IN – = CH1 with simultaneous 50Hz/60Hz rejection and 1x output rate. The first conversion following a POR cycle is accurate within the specification of the device if the power supply voltage is restored to (2.7V to 5.5V) before the end of the POR interval. A new input channel, rejection mode, speed mode, or temperature selection can be programmed into the device during this first data input/output cycle. Reference Voltage Range This converter accepts a truly differential external reference voltage. The absolute/common mode voltage range for REF+ and REF – pins covers the entire operating range of the device (GND to VCC). For correct converter operation, VREF must be positive (REF+ > REF –). The LTC2499 differential reference input range is 0.1V to VCC. For the simplest operation, REF+ can be shorted to VCC and REF – can be shorted to GND. The converter output noise is determined by the thermal noise of the front-end circuits and, as such, its value in nanovolts is nearly constant with reference voltage. A decrease in reference voltage will not significantly improve the converter’s effective resolution. On the other hand, a decreased reference will improve the converter’s overall INL performance. Input Voltage Range The LTC2499 input measurement range is –0.5 • VREF to +0.5 • VREF in both differential and single-ended configurations as shown in Figure 38. Highest linearity is achieved with fully differential drive and a constant common-mode voltage (Figure 38b). Other drive schemes may incur an INL error of approximately 50ppm. This error can be calibrated out using a three point calibration and a second-order curve fit. The analog inputs are truly differential with an absolute, common mode range for the CH0-CH15 and COM input pins extending from GND – 0.3V to VCC + 0.3V. Outside these limits, the ESD protection devices begin to turn on and the errors due to input leakage current increase rapidly. Within these limits, the LTC2499 converts the bipolar differential input signal VIN = IN+ – IN– (where IN+ and IN – are the selected input channels), from – FS = – 0.5 • VREF to + FS = 0.5 • VREF where VREF = REF+ - REF–. Outside this range, the converter indicates the overrange or the underrange condition using distinct output codes (see Table 1). Signals applied to the input (CH0-CH15, COM) may extend 300mV below ground and above VCC. In order to limit any fault current, resistors of up to 5k may be added in series with the input. The effect of series resistance on the converter accuracy can be evaluated from the curves presented in the Input Current/Reference Current sections. In addition, series resistors will introduce a temperature dependent error due to input leakage current. A 1nA input leakage current will develop a 1ppm offset error on a 5k resistor if VREF = 5V. This error has a very strong temperature dependency. MUXOUT/ADCIN The outputs of the multiplexer (MUXOUTP/MUXOUTN) and the inputs to the ADC (ADCINP/ADCINN) can be used to perform input signal conditioning on any of the selected input channels or simply shorted together for direct digitization. If an external amplifier is used, the LTC2499 2499fe For more information www.linear.com/LTC2499 13 LTC2499 Applications Information automatically calibrates both the offset and drift of this circuit and the Easy Drive sampling scheme enables a wide variety of amplifiers to be used. In order to achieve optimum performance, if an external amplifier is not used, short these pins directly together (ADCINP to MUXOUTP and ADCINN to MUXOUTN) and minimize their capacitance to ground. I2C INTERFACE The LTC2499 communicates through an I2C interface. The I2C interface is a 2-wire open-drain interface supporting multiple devices and multiple masters on a single bus. The connected devices can only pull the data line (SDA) LOW and can never drive it HIGH. SDA is required to be externally connected to the supply through a pull-up resistor. When the data line is not being driven, it is HIGH. Data on the I2C bus can be transferred at rates up to 100kbits/s in the standard mode and up to 400kbits/s in the fast mode. The VCC power should not be removed from the device when the I2C bus is active to avoid loading the I2C bus lines through the internal ESD protection diodes. Each device on the I2C bus is recognized by a unique address stored in that device and can operate either as a transmitter or receiver, depending on the function of the device. In addition to transmitters and receivers, devices can also be considered as masters or slaves when performing data transfers. A master is the device which initiates a data transfer on the bus and generates the clock signals to permit that transfer. Devices addressed by the master are considered a slave. The LTC2499 can only be addressed as a slave. Once addressed, it can receive configuration bits (channel selection, rejection mode, speed mode) or transmit the last conversion result. The serial clock line, SCL, is always an input to the LTC2499 and the serial data line SDA is bidirectional. The device supports the standard mode and the fast mode for data transfer speeds up to 400kbits/s. Figure 2 shows the definition of the I2C timing. The START and STOP Conditions A START (S) condition is generated by transitioning SDA from HIGH to LOW while SCL is HIGH. The bus is considered to be busy after the START condition. When the data transfer is finished, a STOP (P) condition is generated by transitioning SDA from LOW to HIGH while SCL is HIGH. The bus is free after a STOP is generated. START and STOP conditions are always generated by the master. When the bus is in use, it stays busy if a repeated START (Sr) is generated instead of a STOP condition. The repeated START timing is functionally identical to the START and is used for writing and reading from the device before the initiation of a new conversion. Data Transferring After the START condition, the I2C bus is busy and data transfer can begin between the master and the addressed slave. Data is transferred over the bus in groups of nine bits, one byte followed by one acknowledge (ACK) bit. The master releases the SDA line during the ninth SCL clock cycle. The slave device can issue an ACK by pulling SDA SDA tLOW tf tSU(DAT) tr tHD(SDA) tf tSP tBUF tr SCL S tHD(SDA) tHD(DAT) tHIGH tSU(STA) Sr tSU(STO) P S 2499 F02 Figure 2. Definition of Timing for Fast/Standard Mode Devices on the I2C Bus 2499fe 14 For more information www.linear.com/LTC2499 LTC2499 Applications Information LOW or issue a Not Acknowledge (NACK) by leaving the SDA line high impedance (the external pull-up resistor will hold the line HIGH). Change of data only occurs while the clock line (SCL) is LOW. cally enters the sleep state where the supply current is reduced to 1µA. When the LTC2499 is addressed for a read operation, it acknowledges (by pulling SDA LOW) and acts as a transmitter. The master/receiver can read up to four bytes from the LTC2499. After a complete read operation (4 bytes), a new conversion is initiated. The device will NACK subsequent read operations while a conversion is being performed. DATA FORMAT After a START condition, the master sends a 7-bit address followed by a read/write (R/W) bit. The R/W bit is 1 for a read request and 0 for a write request. If the 7-bit address matches the hard wired LTC2499’s address (one of 27 pin-selectable addresses) the device is selected. When the device is addressed during the conversion state, it will not acknowledge R/W requests and will issue a NACK by leaving the SDA line HIGH. If the conversion is complete, the LTC2499 issues an ACK by pulling the SDA line LOW. The data output stream is 32 bits long and is shifted out on the falling edges of SCL (see Figure 3a). The first bit is the conversion result sign bit (SIG) (see Tables 1 and 2). This bit is HIGH if VIN ≥ 0 and LOW if VIN < 0 (where VIN corresponds to the selected input signal IN+ – IN–). The second bit is the most significant bit (MSB) of the result. The first two bits (SIG and MSB) can be used to indicate over and under range conditions (see Table 2). If both bits are HIGH, the differential input voltage is equal to or above +FS. If both bits are set LOW, the input voltage is below –FS. The function of these bits is summarized in Table 2. The 24 bits following the MSB bit are the conversion result in binary two’s, complement format. The remaining six bits are sub LSBs below the 24-bit level. The LTC2499 has two registers. The output register (32 bits long) contains the last conversion result. The input register (16 bits long) sets the input channel, selects the temperature sensor, rejection mode, and speed mode. DATA OUTPUT FORMAT The output register contains the last conversion result. After each conversion is completed, the device automatiTable 1. Output Data Format DIFFERENTIAL INPUT VOLTAGE VIN* BIT 31 SIG BIT 30 MSB BIT 29 BIT 28 BIT 27 … BIT 6 LSB BITs 5-0 Sub LSBs VIN* ≥ FS** 1 1 0 0 0 … 0 00000 FS** – 1LSB 1 0 1 1 1 … 1 XXXXX 0.5 • FS** 1 0 1 0 0 … 0 XXXXX 0.5 • FS** – 1LSB 1 0 0 1 1 … 1 XXXXX 1/   0† 0 0 0 0 … 0 XXXXX –1LSB 0 1 1 1 1 … 1 XXXXX –0.5 • FS** 0 1 1 0 0 … 0 XXXXX –0.5 • FS** – 1LSB 0 1 0 1 1 … 1 XXXXX 0 –FS** 0 1 0 0 0 … 0 XXXXX VIN* < –FS** 0 0 1 1 1 … X XXXXX*** *The differential input voltage VIN = IN+ – IN–. **The full-scale voltage FS = 0.5 • VREF . Sub LSBs are below the 24-bit level. They may be included in averaging, or discarded without loss of resolution. †The sign bit changes state during the 0 output code when the device is operating in the 2x speed mode. ***The underrange code is Ox3FFFFxxx in 2x mode. 2499fe For more information www.linear.com/LTC2499 15 LTC2499 Applications Information As long as the voltage on the selected input channels (IN+ and IN–) remains between –0.3V and VCC + 0.3V (absolute maximum operating range) a conversion result is generated for any differential input voltage VIN from –FS = –0.5 • VREF to +FS = 0.5 • VREF . For differential input voltages greater than +FS, the conversion result is clamped to the value corresponding to +FS. For differential input voltages below –FS, the conversion result is clamped to the value –FS – 1LSB. INPUT DATA FORMAT The serial input word to the LTC2499 is 13 bits long and is written into the device input register in two 8-bit words. The first word (SGL, ODD, A2, A1, A0) is used to select the input channel. The second word of data (IM, FA, FB, SPD) is used to select the frequency rejection, speed mode (1x, 2x), and temperature measurement. After power-up, the device initiates an internal reset cycle which sets the input channel to CH0-CH1 (IN+ = CH0, IN– = CH1), the frequency rejection to simultaneous 50Hz/60Hz, and 1x output rate (auto-calibration enabled). The first conversion automatically begins at power-up using this default configuration. Once the conversion is complete, up to two words may be written into the device. Table 2. LTC2499 Status Bits INPUT RANGE BIT 31 SIG BIT 30 MSB 1 1 VIN ≥ FS 0V ≤ VIN < FS 1/  0 0 –FS ≤ VIN < 0V 0 1 VIN < –FS 0 0 1 … 7 8 7-BIT ADDRESS 9 R The first three bits of the first input word consist of two preamble bits and one enable bit. Valid settings for these three bits are 000, 100, and 101. Other combinations should be avoided. 1 2 SGN MSB … 1 2 DIS ACK BY LTC2499 START BY MASTER 9 3 4 5 6 7 8 9 LSB ACK BY MASTER SUB LSBs SLEEP NACK BY MASTER DATA OUTPUT 2499 F03a Figure 3a. Timing Diagram for Reading from the LTC2499 1 SCL 2 … 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 FA FB SPD 6 7 8 9 SDA 7-BIT ADDRESS START BY MASTER 1 W ACK BY LTC2499 SLEEP 0 EN SGL ODD A2 A1 A0 EN2 ACK LTC2499 IM (OPTIONAL 2ND BYTE) ACK LTC2499 DATA INPUT 2499 F03b Figure 3b. Timing Diagram for Writing to the LTC2499 2499fe 16 For more information www.linear.com/LTC2499 LTC2499 Applications Information If the first three bits are 000 or 100, the following data is ignored (don’t care) and the previously selected input channel remains valid for the next conversion If the first three bits shifted into the device are 101, then the next five bits select the input channel for the next conversion cycle (see Table 3). The first input bit (SGL) following the 101 sequence determines if the input selection is differential (SGL = 0) or single-ended (SGL = 1). For SGL = 0, two adjacent channels can be selected to form a differential input. For SGL = 1, one of 16 channels is selected as the positive input. The negative input is COM for all single-ended operations. Table 3. Channel Selection MUX ADDRESS CHANNEL SELECTION ODD/ SGL SIGN A2 A1 A0 0 1 *0 0 0 0 0 IN+ IN– 0 0 0 0 1 0 0 0 1 0 0 0 0 1 1 0 0 1 0 0 0 0 1 0 1 0 0 1 1 0 0 0 1 1 1 0 1 0 0 0 0 1 0 0 1 0 1 0 1 0 0 1 0 1 1 0 1 1 0 0 0 1 1 0 1 0 1 1 1 0 0 1 1 1 1 1 0 0 0 0 1 0 0 0 1 1 0 0 1 0 1 0 0 1 1 1 0 1 0 0 1 0 1 0 1 1 0 1 1 0 1 0 1 1 1 1 1 0 0 0 1 1 0 0 1 1 1 0 1 0 1 1 0 1 1 1 1 1 0 0 1 1 1 0 1 1 1 1 1 0 1 1 1 1 1 IN– 2 3 IN+ IN– 4 5 IN+ IN– 6 7 IN+ IN– 8 9 IN+ IN– 10 11 IN+ IN– 12 13 IN+ IN– 14 15 IN+ IN– IN– IN+ COM IN+ IN– IN+ IN– IN+ IN– IN+ IN– IN+ IN– IN+ IN– IN+ IN+ IN– IN+ IN– IN+ IN– IN+ IN– IN+ IN– IN+ IN– IN+ IN– IN+ IN– IN+ IN– IN+ IN– IN+ IN– IN+ IN– IN+ IN– IN+ IN– IN+ IN– IN+ IN– *Default at power-up 2499fe For more information www.linear.com/LTC2499 17 LTC2499 Applications Information The remaining four bits (ODD, A2, A1, A0) determine which channel(s) is/are selected and the polarity (for a differential input). 1x output rate if SPD = 0 (auto-calibration is enabled and the offset is continuously calibrated and removed from the final conversion result) or the 2x output rate if SPD = 1 (offset calibration disabled, multiplexing output rates up to 15Hz with no latency). When IM = 1 (temperature measurement) SPD will be ignored and the device will operate in 1x mode. Once the first word is written into the device, a second word may be input in order to select a configuration mode. The first bit of the second word is the enable bit for the conversion configuration (EN2). If this bit is set to 0, then the next conversion is performed using the previously selected converter configuration. The configuration remains valid until a new input word with EN = 1 (the first three bits are 101 for the first word) and EN2 = 1 (for the second write byte) is shifted into the device. A new configuration can be loaded into the device by setting EN2 = 1 (see Table 4). The first bit (IM) is used to select the internal temperature sensor. If IM = 1, the following conversion will be performed on the internal temperature sensor rather than the selected input channel. The next two bits (FA and FB) are used to set the rejection frequency. The final bit (SPD) is used to select either the Rejection Mode (FA, FB) The LTC2499 includes a high accuracy on-chip oscillator with no required external components. Coupled with an integrated fourth order digital lowpass filter, the LTC2499 Table 4. Converter Configuration 1 0 EN SGL ODD A2 A1 A0 EN2 IM FA FB SPD CONVERTER CONFIGURATION 1 0 0 X X X X X X X X X X Keep Previous 1 0 1 X X X X X 0 X X X X Keep Previous 0 0 1 X X X X X X X X X X Keep Previous 1 0 1 X X X X X 1 0 0 0 0 External Input (See Table 3) 50Hz/60Hz Rejection, 1x 1 0 1 X X X X X 1 0 0 1 0 External Input (See Table 3) 50Hz Rejection, 1x 1 0 1 X X X X X 1 0 1 0 0 External Input (See Table 3) 60Hz Rejection, 1x 1 0 1 X X X X X 1 0 0 0 1 External Input (See Table 3) 50Hz/60Hz Rejection, 2x 1 0 1 X X X X X 1 0 0 1 1 External Input (See Table 3) 50Hz Rejection, 2x 1 0 1 X X X X X 1 0 1 0 1 External Input (See Table 3) 60Hz Rejection, 2x 1 0 1 X X X X X 1 1 0 0 X Measure Temperature 50Hz/60Hz Rejection, 1x 1 0 1 X X X X X 1 1 0 1 X Measure Temperature 50Hz Rejection, 1x 1 0 1 X X X X X 1 1 1 0 X Measure Temperature 60Hz Rejection, 1x 1 0 1 X X X X X 1 X 1 1 X Reserved, Do Not Use 2499fe 18 For more information www.linear.com/LTC2499 LTC2499 Applications Information rejects line frequency noise. In the default mode, the LTC2499 simultaneously rejects 50Hz and 60Hz by at least 87dB. If more rejection is required, the LTC2499 can be configured to reject 50Hz or 60Hz to better than 110dB. Speed Mode (SPD) Every conversion cycle, two conversions are combined to remove the offset (default mode). This result is free from offset and drift. In applications where the offset is not critical, the auto-calibration feature can be disabled with the benefit of twice the output rate. While operating in the 2x mode (SPD = 1), the linearity and full-scale errors are unchanged from the 1x mode performance. In both the 1x and 2x mode there is no latency. This enables input steps or multiplexer changes to settle in a single conversion cycle, easing system overhead and increasing the effective conversion rate. During temperature measurements, the 1x mode is always used independent of the value of SPD. The digital output is proportional to the absolute temperature of the device. This feature allows the converter to perform cold junction compensation for external thermocouples or continuously remove the temperature effects of external sensors. The internal temperature sensor output is 28mV at 27°C (300°K), with a slope of 93.5µV/°C independent of VREF (see Figures 4 and 5). Slope calibration is not required if the reference voltage (VREF) is known. A 5V reference has a slope of 314 LSBs24/°C. The temperature is calculated from the output code (where DATAOUT24 is the decimal representation of the 24-bit result) for a 5V reference using the following formula: TK = DATAOUT24 in Kelvin 314 If a different value of VREF is used, the temperature output is: TK = DATAOUT24 • VREF in Kelvin 1570 Temperature Sensor The LTC2499 includes an integrated temperature sensor. The temperature sensor is selected by setting IM = 1. During temperature readings, MUXOUTN/MUXOUTP remains connected to the selected input channel. The ADC internally connects to the temperature sensor and performs a conversion. If the value of VREF is not known, the slope is determined by measuring the temperature sensor at a known temperature TN (in K) and using the following formula: 140000 5 VCC = 5V VREF = 5V 120000 SLOPE = 314 LSB /K 24 4 ABSOLUTE ERROR (°C) 3 DATAOUT24 100000 80000 60000 40000 2 1 0 –1 –2 –3 20000 0 DATAOUT24 TN SLOPE = –4 0 100 200 300 TEMPERATURE (K) 400 –5 –55 2499 F04 Figure 4. Internal PTAT Digital Output vs Temperature –30 –5 20 45 70 TEMPERATURE (°C) 95 120 2499 F05 Figure 5. Absolute Temperature Error 2499fe For more information www.linear.com/LTC2499 19 LTC2499 Applications Information This value of slope can be used to calculate further temperature readings using: TK = DATAOUT24 SLOPE All Kelvin temperature readings can be converted to TC (°C) using the fundamental equation: TC = TK – 273 Initiating a New Conversion When the LTC2499 finishes a conversion, it automatically enters the sleep state. Once in the sleep state, the device is ready for a read operation. After the device acknowledges a read request, the device exits the sleep state and enters the data output state. The data output state concludes and the LTC2499 starts a new conversion once a STOP condition is issued by the master or all 32 bits of data are read out of the device. During the data read cycle, a STOP command may be issued by the master controller in order to start a new conversion and abort the data transfer. This STOP command must be issued during the ninth clock cycle of a byte read when the bus is free (the ACK/NACK cycle). LTC2499 Address The LTC2499 has three address pins (CA0, CA1, CA2). Each may be tied HIGH, LOW, or left floating enabling one of 27 possible addresses (see Table 5). In addition to the configurable addresses listed in Table 5, the LTC2499 also contains a global address (1110111) which may be used for synchronizing multiple LTC2499s or other LTC24XX delta-sigma I2C devices (see Synchronizing Multiple LTC2499s with a Global Address Call section). Operation Sequence The LTC2499 acts as a transmitter or receiver, as shown in Figure 6. The device may be programmed to perform several functions. These include input channel selection, measure the internal temperature, selecting the line frequency rejection (50Hz, 60Hz, or simultaneous 50Hz and 60Hz), and a 2x speed mode. Table 5. Address Assignment CA2 CA1 CA0 ADDRESS LOW LOW LOW 0010100 LOW LOW HIGH 0010110 LOW LOW Float 0010101 LOW HIGH LOW 0100110 LOW HIGH HIGH 0110100 LOW HIGH Float 0100111 LOW Float LOW 0010111 LOW Float HIGH 0100101 LOW Float Float 0100100 HIGH LOW LOW 1010110 HIGH LOW HIGH 1100100 HIGH LOW Float 1010111 HIGH HIGH LOW 1110100 HIGH HIGH HIGH 1110110 HIGH HIGH Float 1110101 HIGH Float LOW 1100101 HIGH Float HIGH 1100111 HIGH Float Float 1100110 Float LOW LOW 0110101 Float LOW HIGH 0110111 Float LOW Float 0110110 Float HIGH LOW 1000111 Float HIGH HIGH 1010101 Float HIGH Float 1010100 Float Float LOW 1000100 Float Float HIGH 1000110 Float Float Float 1000101 Continuous Read In applications where the input channel/configuration does not need to change for each cycle, the conversion can be continuously performed and read without a write cycle (see Figure 7). The configuration/input channel remains unchanged from the last value written into the device. If the device has not been written to since power-up, the configuration is set to the default value. At the end of a read operation, a new conversion automatically begins. At the conclusion of the conversion cycle, the next result may be read using the method described above. If the conversion cycle is not concluded and a valid address 2499fe 20 For more information www.linear.com/LTC2499 LTC2499 Applications Information S R/W 7-BIT ADDRESS CONVERSION ACK DATA SLEEP Sr DATA TRANSFERRING P DATA INPUT/OUTPUT CONVERSION 2499 F05 Figure 6. Conversion Sequence S 7-BIT ADDRESS CONVERSION R ACK SLEEP READ P S 7-BIT ADDRESS CONVERSION DATA OUTPUT R ACK SLEEP READ P DATA OUTPUT CONVERSION 2499 F07 Figure 7. Consecutive Reading with the Same Input/Configuration S 7-BIT ADDRESS CONVERSION W ACK SLEEP WRITE Sr 7-BIT ADDRESS DATA INPUT ADDRESS R ACK READ DATA OUTPUT P CONVERSION 2499 F08 Figure 8. Write, Read, START Conversion S 7-BIT ADDRESS CONVERSION W ACK SLEEP WRITE (OPTIONAL) DATA INPUT P CONVERSION 2499 F09 Figure 9. Start a New Conversion Without Reading Old Conversion Result 2499fe For more information www.linear.com/LTC2499 21 LTC2499 Applications Information selects the device, the LTC2499 generates a NACK signal indicating the conversion cycle is in progress. Continuous Read/Write Once the conversion cycle is concluded, the LTC2499 can be written to and then read from using the repeated START (Sr) command. Figure 8 shows a cycle which begins with a data write, a repeated START, followed by a read and concluded with a STOP command. The following conversion begins after all 32 bits are read out of the device or after a STOP command. The following conversion will be performed using the newly programmed data. In cases where the same speed (1x/2x mode) and rejection frequency (50Hz, 60Hz, 50Hz and 60Hz) is used but the channel is changed, a STOP or repeated START may be issued after the first byte (channel selection data) is written into the device. Discarding a Conversion Result and Initiating a New Conversion with Optional Write At the conclusion of a conversion cycle, a write cycle can be initiated. Once the write cycle is acknowledged, a STOP command will start a new conversion. If a new input channel or conversion configuration is required, this data can be written into the device and a STOP command will initiate the next conversion (see Figure 9). Synchronizing Multiple LTC2499s with a Global Address Call In applications where several LTC2499s (or other I2C delta-sigma ADCs from Linear Technology Corporation) are used on the same I2C bus, all converters can be synchronized through the use of a global address call. Prior to issuing the global address call, all converters must have completed a conversion cycle. The master then issues a START, followed by the global address 1110111, and a write request. All converters will be selected and acknowledge the request. The master then sends a write byte (optional) followed by the STOP command. This will update the channel selection (optional) converter configuration (optional) and simultaneously initiate a START of conversion for all delta-sigma ADCs on the bus (see Figure 10). In order to synchronize multiple converters without changing the channel or configuration, a STOP may be issued after acknowledgement of the global write command. Global read commands are not allowed and the converters will NACK a global read request. SCL SDA LTC2499 S LTC2499 GLOBAL ADDRESS ALL LTC2499s IN SLEEP W ACK … WRITE (OPTIONAL) LTC2499 P DATA INPUT CONVERSION OF ALL LTC2499s 2499 F10 Figure 10. Synchronize Multiple LTC2499s with a Global Address Call 2499fe 22 For more information www.linear.com/LTC2499 LTC2499 Applications Information Driving the Input and Reference The input and reference pins of the LTC2499 are connected directly to a switched capacitor network. Depending on the relationship between the differential input voltage and the differential reference voltage, these capacitors are switched between these four pins. Each time a capacitor is switched between two of these pins, a small amount of charge is transferred. A simplified equivalent circuit is shown in Figure 11. When using the LTC2499’s internal oscillator, the input capacitor array is switched at 123kHz. The effect of the charge transfer depends on the circuitry driving the input/ reference pins. If the total external RC time constant is less than 580ns the errors introduced by the sampling process are negligible since complete settling occurs. Typically, the reference inputs are driven from a low impedance source. In this case, complete settling occurs even with large external bypass capacitors. The inputs (CH0-CH15, COM), on the other hand, are typically driven from larger source resistances. Source resistances up to 10k may interface directly to the LTC2499 and settle completely; however, the addition of external capacitors at the input terminals in order to filter unwanted noise (anti-aliasing) results in incomplete settling. The LTC2499 offers two methods of removing these errors. The first is an automatic differential input current IIN+ IN+ INPUT MULTIPLEXER 100Ω Automatic Differential Input Current Cancellation In applications where the sensor output impedance is low (up to 10kΩ with no external bypass capacitor or up to 500Ω with 0.001µF bypass), complete settling of the input occurs. In this case, no errors are introduced and direct digitization is possible. For many applications, the sensor output impedance combined with external input bypass capacitors produces RC time constants much greater than the 580ns required for 1ppm accuracy. For example, a 10kΩ bridge driving a 0.1µF capacitor has a time constant an order of magnitude greater than the required maximum. The LTC2499 uses a proprietary switching algorithm that forces the average differential input current to zero independent of external settling errors. This allows direct digitization of high impedance sensors without the need for buffers. The switching algorithm forces the average input current on the positive input (IIN+) to be equal to the average input current on the negative input (IIN–). Over the complete conversion cycle, the average differential input current INTERNAL SWITCH NETWORK EXTERNAL CONNECTION MUXOUTP cancellation (Easy Drive) and the second is the insertion of an external buffer between the MUXOUT and ADCIN pins, thus isolating the input switching from the source resistance. ADCINP 10kΩ ( ) I IN+ ( I REF + IIN– IN– IREF+ AVG 100Ω MUXOUTN ADCINN SWITCHING FREQUENCY fSW = 123kHz INTERNAL OSCILLATOR fSW = 0.4 • fEOSC EXTERNAL OSCILLATOR ≈ AVG VIN(CM) − VREF(CM) = 0.5•REQ ( 1.5VREF + VREF(CM) – VIN(CM) 0.5 • REQ )– VIN2 VREF • REQ VREF = REF + − REF − CEQ 12µF 10kΩ IREF– REF– AVG ( ) where: 10kΩ EXTERNAL CONNECTION REF+ ) = I IN– ⎛ REF + – REF − ⎞ VREF(CM) = ⎜ ⎟ ⎜⎝ ⎟⎠ 2 VIN = IN+ − IN− , WHERE IN+ AND IN− ARE THE SELECTED INPUT CHANNELS ⎛ IN+ – IN− ⎞ VIN(CM) = ⎜ ⎟ ⎜⎝ ⎟⎠ 2 REQ = 2.71MΩ INTERNAL OSCILLATOR 60Hz MODE REQ = 2.98MΩ INTERNAL OSCILLATOR 50Hz/60Hz MODE 10kΩ 2499 F11 REQ = 0.833• 1012 /fEOSC EXTERNAL OSCILLATOR ( ) Figure 11. Equivalent Analog Input Circuit 2499fe For more information www.linear.com/LTC2499 23 LTC2499 Applications Information (IIN+ – IIN–) is zero. While the differential input current is zero, the common mode input current (IIN+ + IIN–)/2 is proportional to the difference between the common mode input voltage (VIN(CM)) and the common mode reference voltage (VREF(CM)). In applications where the input common mode voltage is equal to the reference common mode voltage, as in the case of a balanced bridge, both the differential and common mode input current are zero. The accuracy of the converter is not compromised by settling errors. In applications where the input common mode voltage is constant but different from the reference common mode voltage, the differential input current remains zero while the common mode input current is proportional to the difference between VIN(CM) and VREF(CM). For a reference common mode voltage of 2.5V and an input common mode of 1.5V, the common mode input current is approximately 0.74µA (in simultaneous 50Hz/60Hz rejection mode). This common mode input current does not degrade the accuracy if the source impedances tied to IN+ and IN– are matched. Mismatches in source impedance lead to a fixed offset error but do not effect the linearity or full-scale reading. A 1% mismatch in a 1k source resistance leads to a 74µV shift in offset voltage. ANALOG INPUTS ∆Σ ADC SDA WITH EASY DRIVE SCL INPUTS MUXOUTN INPUT MUX MUXOUTP 17 LTC2499 2 3 6 5 – 1/2 LTC6078 1 + – 1/2 LTC6078 + 1k 0.1µF 7 1k 2499 F12 0.1µF Figure 12. External Buffers Provide High Impedance Inputs and Amplifier Offsets are Automatically Cancelled In applications where the common mode input voltage varies as a function of the input signal level (single-ended type sensors), the common mode input current varies proportionally with input voltage. For the case of balanced input impedances, the common mode input current effects are rejected by the large CMRR of the LTC2499, leading to little degradation in accuracy. Mismatches in source impedances lead to gain errors proportional to the difference between the common mode input and common mode reference. 1% mismatches in 1k source resistances lead to gain errors on the order of 15ppm. Based on the stability of the internal sampling capacitors and the accuracy of the internal oscillator, a one-time calibration will remove this error. In addition to the input sampling current, the input ESD protection diodes have a temperature dependent leakage current. This current, nominally 1nA (±10nA max), results in a small offset shift. A 1k source resistance will create a 1µV typical and a 10µV maximum offset voltage. Automatic Offset Calibration of External Buffers/ Amplifiers In addition to the Easy Drive input current cancellation, the LTC2499 allows an external amplifier to be inserted between the multiplexer output and the ADC input (see Figure 12). This is useful in applications where balanced source impedances are not possible. One pair of external buffers/amplifiers can be shared between all 17 analog inputs. The LTC2499 performs an internal offset calibration every conversion cycle in order to remove the offset and drift of the ADC. This calibration is performed through a combination of front end switching and digital processing. Since the external amplifier is placed between the multiplexer and the ADC, it is inside this correction loop. This results in automatic offset correction and offset drift removal of the external amplifier. The LTC6078 is an excellent amplifier for this function. It operates with supply voltages as low as 2.7V and its noise level is 18nV/√Hz. The Easy Drive input technology of the LTC2499 enables an RC network to be added directly to the output of the LTC6078. The capacitor reduces the magnitude of the current spikes seen at the input to the ADC and the resistor isolates the capacitor load from the 2499fe 24 For more information www.linear.com/LTC2499 LTC2499 Applications Information op amp output enabling stable operation. The LTC6078 can also be biased at supply rails beyond those used by the LTC2499. This allows the external sensor to swing railto-rail (–0.3V to VCC + 0.3V) without the need of external level-shift circuitry. Reference Current Similar to the analog inputs, the LTC2499 samples the differential reference pins (REF+ and REF–) transferring small amounts of charge to and from these pins, thus producing a dynamic reference current. If incomplete settling occurs (as a function the reference source resistance and reference bypass capacitance) linearity and gain errors are introduced. 90 60 50 0 CREF = 0.01µF CREF = 0.001µF CREF = 100pF CREF = 0pF 40 30 20 –20 –30 –40 –50 VCC = 5V –60 VREF = 5V V + = 1.25V –70 VIN– = 3.75V IN –80 fO = GND TA = 25°C –90 10 0 10 0 –10 0 10 CREF = 0.01µF CREF = 0.001µF CREF = 100pF CREF = 0pF –10 –FS ERROR (ppm) +FS ERROR (ppm) 70 In cases where large bypass capacitors are required on the reference inputs (CREF > .01µF), full-scale and linearity errors are proportional to the value of the reference resistance. Every ohm of reference resistance produces a full-scale error of approximately 0.5ppm (while operating in simultaneous 50Hz/60Hz mode (see Figures 15 and 16)). If the input common mode voltage is equal to the reference common mode voltage, a linearity error of 10 VCC = 5V VREF = 5V VIN+ = 3.75V VIN– = 1.25V fO = GND TA = 25°C 80 For relatively small values of external reference capacitance (CREF < 1nF), the voltage on the sampling capacitor settles for reference impedances of many kΩ (if CREF = 100pF up to 10kΩ will not degrade the performance (see Figures 13 and 14)). 1k 100 RSOURCE (Ω) 10k 100k 1k 100 RSOURCE (Ω) 10k 2499 F13 Figure 13. +FS Error vs RSOURCE at VREF (Small CREF) VCC = 5V VREF = 5V VIN+ = 3.75V VIN– = 1.25V fO = GND TA = 25°C +FS ERROR (ppm) 400 300 Figure 14. –FS Error vs RSOURCE at VREF (Small CREF) 0 CREF = 1µF, 10µF –100 CREF = 0.1µF 200 CREF = 0.01µF 100 0 2499 F14 –FS ERROR (ppm) 500 CREF = 0.01µF –200 CREF = 1µF, 10µF –300 VCC = 5V VREF = 5V VIN+ = 1.25V VIN– = 3.75V fO = GND TA = 25°C –400 0 200 100k 600 400 RSOURCE (Ω) 800 1000 –500 0 2499 F15 Figure 15. +FS Error vs RSOURCE at VREF (Large CREF) 200 CREF = 0.1µF 600 400 RSOURCE (Ω) 800 1000 2499 F16 Figure 16. –FS Error vs RSOURCE at VREF (Large CREF) 2499fe For more information www.linear.com/LTC2499 25 LTC2499 Applications Information approximately 0.67ppm per 100Ω of reference resistance results (see Figure 17). In applications where the input and reference common mode voltages are different, the errors increase. A 1V difference in between common mode input and common mode reference results in a 6.7ppm INL error for every 100Ω of reference resistance. INL (ppm OF VREF) 10 VCC = 5V 8 VREF = 5V VIN(CM) = 2.5V 6 T = 25°C A 4 CREF = 10µF R = 500Ω 0 R = 100Ω –2 –4 –6 –8 –10 –0.5 –0.3 0.1 –0.1 VIN/VREF 0.3 Normal Mode Rejection and Anti-Aliasing One of the advantages delta-sigma ADCs offer over conventional ADCs is on-chip digital filtering. Combined with a large oversample ratio, the LTC2499 significantly simplifies anti-aliasing filter requirements. Additionally, the input current cancellation feature allows external lowpass filtering without degrading the DC performance of the device. R = 1k 2 In addition to the reference sampling charge, the reference ESD protection diodes have a temperature dependent leakage current. This leakage current, nominally 1nA (±10nA max) results in a small gain error. A 100Ω reference resistance will create a 0.5µV full-scale error. 0.5 2499 F17 Figure 17. INL vs Differential Input Voltage and Reference Source Resistance for CREF > 1µF The SINC4 digital filter provides excellent normal mode rejection at all frequencies except DC and integer multiples of the modulator sampling frequency (fS) (see Figures 18 and 19). The modulator sampling frequency is fS = 15,360Hz while operating with its internal oscillator and fS = fEOSC/20 when operating with an external oscillator of frequency fEOSC . 0 INPUT NORMAL MODE REJECTION (dB) INPUT NORMAL MODE REJECTION (dB) 0 –10 –20 –30 –40 –50 –60 –70 –80 –90 –100 –110 –120 0 fS 2fS 3fS 4fS 5fS 6fS 7fS 8fS 9fS 10fS11fS12fS DIFFERENTIAL INPUT SIGNAL FREQUENCY (Hz) –10 –20 –30 –40 –50 –60 –70 –80 –90 –100 –110 –120 0 fS 2fS 3fS 4fS 5fS 6fS 7fS 8fS 9fS 10fS DIFFERENTIAL INPUT SIGNAL FREQUENCY (Hz) 2499 F18 2499 F19 Figure 19. Input Normal Mode Rejection, Internal Oscillator and 60Hz Rejection Mode Figure 18. Input Normal Mode Rejection, Internal Oscillator and 50Hz Rejection Mode 2499fe 26 For more information www.linear.com/LTC2499 LTC2499 Applications Information When using the internal oscillator, the LTC2499 is designed to reject line frequencies. As shown in Figure 20, rejection nulls occur at multiples of frequency fN, where fN is determined by the input control bits FA and FB (fN = 50Hz or 60Hz or 55Hz for simultaneous rejection). Multiples of the modulator sampling rate (fS = fN • 256) only reject noise to 15dB (see Figure 21); if noise sources are present at these frequencies anti-aliasing will reduce their effects. The user can expect to achieve this level of performance using the internal oscillator, as shown in Figures 22, 23, and 24. Measured values of normal mode rejection are shown superimposed over the theoretical values in all three rejection modes. INPUT NORMAL MODE REJECTION (dB) 0 Traditional high order delta-sigma modulators suffer from potential instabilities at large input signal levels. The proprietary architecture used for the LTC2499 third-order modulator resolves this problem and guarantees stability with input signals 150% of full scale. In many industrial applications, it is not uncommon to have microvolt level signals superimposed over unwanted error sources with several volts if peak-to-peak noise. Figures 25 and 26 show measurement results for the rejection of a 7.5V peak-to-peak noise source (150% of full scale) applied to the LTC2499. These curves show that the rejection performance is maintained even in extremely noisy environments. fN = fEOSC/5120 –10 –20 –30 –40 –50 –60 –70 –80 –90 –100 –110 –120 0 fN 2fN 3fN 4fN 5fN 6fN 7fN INPUT SIGNAL FREQUENCY (Hz) 8fN 2499 F20 Figure 20. Input Normal Mode Rejection at DC INPUT NORMAL MODE REJECTION (dB) 0 –10 fN = fEOSC/5120 –20 –30 –40 –50 –60 –70 –80 –90 –100 –110 –120 250fN 252fN 254fN 256fN 258fN 260fN 262fN INPUT SIGNAL FREQUENCY (Hz) 2499 F21 Figure 21. Input Normal Mode Rejection at fS = 256 • fN 2499fe For more information www.linear.com/LTC2499 27 LTC2499 Applications Information VCC = 5V VREF = 5V VIN(CM) = 2.5V VIN(P-P) = 5V TA = 25°C MEASURED DATA CALCULATED DATA –20 –40 –60 –80 –100 –120 0 15 30 45 60 75 0 NORMAL MODE REJECTION (dB) NORMAL MODE REJECTION (dB) 0 –20 –40 –80 –100 0 12.5 25 37.5 50 62.5 75 87.5 100 112.5 125 137.5 150 162.5 175 187.5 200 INPUT FREQUENCY (Hz) 2498 F22 NORMAL MODE REJECTION (dB) 0 MEASURED DATA CALCULATED DATA –20 –40 VCC = 5V VREF = 5V VIN(CM) = 2.5V VIN(P-P) = 5V TA = 25°C –60 –80 –100 –120 0 20 40 60 80 100 120 140 INPUT FREQUENCY (Hz) 160 180 200 220 2498 F23 Figure 23. Input Normal Mode Rejection vs Input Frequency with Input Perturbation of 100% (50Hz Notch) 0 NORMAL MODE REJECTION (dB) Figure 22. Input Normal Mode Rejection vs Input Frequency with Input Perturbation of 100% (60Hz Notch) VIN(P-P) = 5V VIN(P-P) = 7.5V (150% OF FULL SCALE) –20 –60 –80 –100 –120 0 15 30 45 60 75 90 105 120 135 150 165 180 195 210 225 240 INPUT FREQUENCY (Hz) 2498 F26 Figure 25. Measure Input Normal Mode Rejection vs Input Frequency with Input Perturbation of 150% (60Hz Notch) NORMAL MODE REJECTION (dB) 0 VIN(P-P) = 5V VIN(P-P) = 7.5V (150% OF FULL SCALE) –20 VCC = 5V VREF = 5V VIN(CM) = 2.5V TA = 25°C –40 2498 F24 Figure 24. Input Normal Mode Rejection vs Input Frequency with Input Perturbation of 100% (50Hz/60Hz Notch) VCC = 5V VREF = 5V VIN(CM) = 2.5V VIN(P-P) = 5V TA = 25°C –60 –120 90 105 120 135 150 165 180 195 210 225 240 INPUT FREQUENCY (Hz) MEASURED DATA CALCULATED DATA VCC = 5V VREF = 5V VIN(CM) = 2.5V TA = 25°C –40 –60 –80 –100 –120 0 12.5 25 37.5 50 62.5 75 87.5 100 112.5 125 137.5 150 162.5 175 187.5 200 INPUT FREQUENCY (Hz) 2498 F27 Figure 26. Measure Input Normal Mode Rejection vs Input Frequency with Input Perturbation of 150% (50Hz Notch) 2499fe 28 For more information www.linear.com/LTC2499 LTC2499 Applications Information Using the 2X speed mode of the LTC2499 alters the rejection characteristics around DC and multiples of fS. The device bypasses the offset calibration in order to increase the output rate. The resulting rejection plots are shown in Figures 27 and 28. 1x type frequency rejection can be achieved using the 2x mode by performing a running average of the previous two conversion results (see Figure 29). Output Data Rate When using its internal oscillator, the LTC2499 produces up to 7.5 samples per second (sps) with a notch frequency of 60Hz. The actual output data rate depends upon the length of the sleep and data output cycles which are controlled by the user and can be made insignificantly short. When operating with an external conversion clock (fO connected to an external oscillator), the LTC2499 output data rate can be increased. The duration of the conversion cycle is 41036/fEOSC. If fEOSC = 307.2kHz, the converter behaves as if the internal oscillator is used. A change in fEOSC results in a proportional change in the internal notch position. This leads to reduced differential mode rejection of line frequencies. The common mode rejection of line frequencies remains unchanged, thus fully differential input signals with a high degree of symmetry on both the IN+ and IN – pins will continue to reject line frequency noise. An increase in fEOSC also increases the effective dynamic input and reference current. External RC networks will continue to have zero differential input current, but the time required for complete settling (580ns for fEOSC = 307.2kHz) is reduced, proportionally. Once the external oscillator frequency is increased above 1MHz (a more than 3x increase in output rate) the effectiveness of internal auto calibration circuits begins to degrade. This results in larger offset errors, full-scale errors, and decreased resolution, as seen in Figures 30-37. 0 0 –20 –20 INPUT NORMAL REJECTION (dB) INPUT NORMAL REJECTION (dB) An increase in fEOSC over the nominal 307.2kHz will translate into a proportional increase in the maximum output data rate (up to a maximum of 100sps). The increase in output rate leads to degradation in offset, full-scale error, and effective resolution as well as a shift in frequency rejection. When using the integrated temperature sensor, the internal oscillator should be used or an external oscillator fEOSC = 307.2kHz maximum. –40 –60 –80 –100 –120 0 fN 2fN 3fN 4fN 5fN 6fN 7fN INPUT SIGNAL FREQUENCY (fN) 8fN –40 –60 –80 –100 –120 248 250 252 254 256 258 260 262 264 INPUT SIGNAL FREQUENCY (fN) 2499 F28 2499 F27 Figure 27. Input Normal Mode Rejection 2x Speed Mode Figure 28. Input Normal Mode Rejection 2x Speed Mode 2499fe For more information www.linear.com/LTC2499 29 LTC2499 Applications Information 50 –90 WITH RUNNING AVERAGE –110 –120 –130 –140 60 62 54 56 58 48 50 52 DIFFERENTIAL INPUT SIGNAL FREQUENCY (Hz) 30 20 10 –10 –500 22 –1000 20 RESOLUTION (BITS) –FS ERROR (ppm OF VREF) 24 500 0 10 20 OUTPUT DATA RATE (READINGS/SEC) 16 TA = 25°C TA = 85°C VIN(CM) = VREF(CM) VCC = VREF = 5V VIN = 0V fO = EXT CLOCK RES = LOG 2 (VREF/NOISERMS) 14 10 0 20 10 OUTPUT DATA RATE (READINGS/SEC) 30 –5 30 10 20 OUTPUT DATA RATE (READINGS/SEC) 2499 F35 Figure 35. Offset Error vs Output Data Rate and Reference Voltage 16 TA = 25°C TA = 85°C VIN(CM) = VREF(CM) 12 VCC = VREF = 5V fO = EXT CLOCK RES = LOG 2 (VREF/INLMAX) 10 0 20 10 OUTPUT DATA RATE (READINGS/SEC) 14 30 2499 F34 Figure 34. Resolution (INLMAX ≤ 1LSB) vs Output Data Rate and Temperature 22 22 0 18 2499 F33 RESOLUTION (BITS) OFFSET ERROR (ppm OF VREF) 2499 F31 24 5 30 Figure 31. +FS Error vs Output Data Rate and Temperature Figure 33. Resolution (NoiseRMS ≤ 1LSB) vs Output Data Rate and Temperature 20 VIN(CM) = VREF(CM) VIN = 0V 15 fO = EXT CLOCK TA = 25°C VCC = VREF = 5V 10 V = 5V, V CC REF = 2.5V 20 10 OUTPUT DATA RATE (READINGS/SEC) 20 12 30 0 22 2499 F32 0 0 30 18 Figure 32.–FS Error vs Output Data Rate and Temperature –10 1000 Figure 30. Offset Error vs Output Data Rate and Temperature 0 –2500 TA = 25°C TA = 85°C V = VREF(CM) –3000 IN(CM) VCC = VREF = 5V fO = EXT CLOCK –3500 0 10 20 OUTPUT DATA RATE (READINGS/SEC) 1500 2499 F30 2499 F29 –2000 2000 0 Figure 29. Input Normal Mode Rejection 2x Speed Mode with and Without Running Averaging –1500 2500 20 20 RESOLUTION (BITS) –100 40 VIN(CM) = VREF(CM) VCC = VREF = 5V fO = EXT CLOCK TA = 25°C TA = 85°C 3000 +FS ERROR (ppm OF VREF) NO AVERAGE 3500 VIN(CM) = VREF(CM) VCC = VREF = 5V VIN = 0V fO = EXT CLOCK TA = 25°C TA = 85°C RESOLUTION (BITS) –80 OFFSET ERROR (ppm OF VREF) NORMAL MODE REJECTION (dB) –70 18 16 VCC = VREF = 5V VCC = 5V, VREF = 2.5V 14 VIN(CM) = VREF(CM) VIN = 0V fO = EXT CLOCK 12 T = 25°C A RES = LOG 2 (VREF/NOISERMS) 10 0 20 10 OUTPUT DATA RATE (READINGS/SEC) 30 2499 F36 Figure 36. Resolution (NoiseRMS ≤ 1LSB) vs Output Data Rate and Reference Voltage 18 16 VCC = VREF = 5V VCC = 5V, VREF = 2.5V VIN(CM) = VREF(CM) 14 VIN = 0V REF– = GND 12 fO = EXT CLOCK TA = 25°C RES = LOG 2 (VREF/INLMAX) 10 0 10 20 OUTPUT DATA RATE (READINGS/SEC) 30 2499 F37 Figure 37. Resolution (INLMAX ≤ 1LSB) vs Output Data Rate and Reference Voltage 2499fe 30 For more information www.linear.com/LTC2499 LTC2499 Applications Information VCC + 0.3V VCC VREF 2 GND –0.3V VCC VREF 2 –VREF 2 VREF 2 –VREF 2 GND (a) Arbitrary (b) Fully Differential VCC VCC VREF 2 VREF 2 –VREF 2 GND (c) Pseudo Differential Bipolar IN– or COM Biased Selected IN+ Ch Selected IN– Ch or COM –0.3V GND –0.3V (d) Pseudo-Differential Unipolar IN– or COM Grounded 2499 F38 Figure 38. Input Range 2499fe For more information www.linear.com/LTC2499 31 LTC2499 Package Description Please refer to http://www.linear.com/designtools/packaging/ for the most recent package drawings. UHF Package 38-Lead Plastic QFN (5mm × 7mm) (Reference LTC DWG # 05-08-1701 Rev C) 0.70 ±0.05 5.50 ±0.05 5.15 ±0.05 4.10 ±0.05 3.00 REF 3.15 ±0.05 PACKAGE OUTLINE 0.25 ±0.05 0.50 BSC 5.5 REF 6.10 ±0.05 7.50 ±0.05 RECOMMENDED SOLDER PAD LAYOUT APPLY SOLDER MASK TO AREAS THAT ARE NOT SOLDERED 0.75 ±0.05 5.00 ±0.10 PIN 1 NOTCH R = 0.30 TYP OR 0.35 × 45° CHAMFER 3.00 REF 37 0.00 – 0.05 38 0.40 ±0.10 PIN 1 TOP MARK (SEE NOTE 6) 1 2 5.15 ±0.10 5.50 REF 7.00 ±0.10 3.15 ±0.10 (UH) QFN REF C 1107 0.200 REF 0.25 ±0.05 0.50 BSC R = 0.125 TYP R = 0.10 TYP BOTTOM VIEW—EXPOSED PAD NOTE: 1. DRAWING CONFORMS TO JEDEC PACKAGE OUTLINE M0-220 VARIATION WHKD 2. DRAWING NOT TO SCALE 3. ALL DIMENSIONS ARE IN MILLIMETERS 4. DIMENSIONS OF EXPOSED PAD ON BOTTOM OF PACKAGE DO NOT INCLUDE MOLD FLASH. MOLD FLASH, IF PRESENT, SHALL NOT EXCEED 0.20mm ON ANY SIDE 5. EXPOSED PAD SHALL BE SOLDER PLATED 6. SHADED AREA IS ONLY A REFERENCE FOR PIN 1 LOCATION ON THE TOP AND BOTTOM OF PACKAGE 2499fe 32 For more information www.linear.com/LTC2499 LTC2499 Revision History (Revision history begins at Rev C) REV DATE DESCRIPTION PAGE NUMBER C 11/09 Update Tables 1 and 2 16 D 7/10 Revised Typical Application drawing. 1 Added fO pin to parameters of VIHA in I2C Inputs and Digital Outputs section 4 Added text to first paragraph of I2C Interface section E 11/14 Clarified performance vs frequency, reduced External Oscillator Max frequency to 1MHz Clarified Input Voltage Range Added underrange note to Table 1 15 5, 9, 30 3, 4, 13, 31 15 2499fe Information furnished by Linear Technology Corporation is believed to be accurate and reliable. However, no responsibility is assumed for its use. Linear Technology Corporation makes no representation that the interconnection of its circuits as described herein will not infringe on existing patent rights. For more information www.linear.com/LTC2499 33 LTC2499 Typical Application External Buffers Provide High Impedance Inputs and Amplifier Offsets Are Automatically Cancelled ΔΣ ADC WITH EASY DRIVE INPUTS MUXOUTN 2 – 1/2 LTC6078 3 + 6 – 5 1/2 LTC6078 + 1 SDA SCL 1k 0.1µF 7 1k 2499 TA03 INPUT MUX MUXOUTP LTC2499 ANALOG 17 INPUTS 0.1µF Related Parts PART NUMBER DESCRIPTION COMMENTS LT 1236A-5 Precision Bandgap Reference, 5V 0.05% Max Initial Accuracy, 5ppm/°C Drift LT1460 Micropower Series Reference 0.075% Max Initial Accuracy, 10ppm/°C Max Drift LT1790 Micropower SOT-23 Low Dropout Reference Family 0.05% Max Initial Accuracy, 10ppm/°C Max Drift LTC2400 24-Bit, No Latency ΔΣ ADC in SO-8 0.3ppm Noise, 4ppm INL, 10ppm Total Unadjusted Error, 200µA LTC2410 24-Bit, No Latency ΔΣ ADC with Differential Inputs 0.8µVRMS Noise, 2ppm INL LTC2411/ LTC2411-1 24-Bit, No Latency ΔΣ ADCs with Differential Inputs in MSOP 1.45µVRMS Noise, 2ppm INL, Simultaneous 50Hz/60Hz Rejection (LTC2411-1) ® LTC2413 24-Bit, No Latency ΔΣ ADC with Differential Inputs Simultaneous 50Hz/60Hz Rejection, 800nVRMS Noise LTC2440 24-Bit, High Speed, Low Noise ΔΣ ADC 3.5kHz Output Rate, 200nVRMS Noise, 24.6 ENOBs LTC2442 24-Bit, High Speed, 2-/4-Channel ΔΣ ADC with Integrated Amplifier 8kHz Output Rate, 200nVRMS Noise, Simultaneous 50Hz/60Hz Rejection LTC2449 24-Bit, High Speed, 8-/16-Channel ΔΣ ADC 8kHz Output Rate, 200nVRMS Noise, Simultaneous 50Hz/60Hz Rejection LTC2480/LTC2482/ LTC2484 16-Bit/24-Bit ΔΣ ADCs with Easy Drive Inputs, 600nVRMS Noise, Pin-Compatible with 16-Bit and 24-Bit Versions Programmable Gain, and Temperature Sensor LTC2481/LTC2483/ LTC2485 16-Bit/24-Bit ΔΣ ADCs with Easy Drive Inputs, 600nVRMS Noise, Pin-Compatible with 16-Bit and 24-Bit Versions I2C Interface, Programmable Gain, and Temperature Sensor LTC2496 16-Bit 8-/16-Channel ΔΣ ADC with Easy Drive Inputs and SPI Interface Pin-Compatible with LTC2498/LTC2449 LTC2497 16-Bit 8-/16-Channel ΔΣ ADC with Easy Drive Inputs and I2C Interface Pin-Compatible with LTC2499 LTC2498 24-Bit 8-/16-Channel ΔΣ ADC with Easy Drive Inputs and SPI Interface, Temperature Sensor Pin-Compatible with LTC2496/LTC2449 2499fe 34 Linear Technology Corporation 1630 McCarthy Blvd., Milpitas, CA 95035-7417 For more information www.linear.com/LTC2499 (408) 432-1900 ● FAX: (408) 434-0507 ● www.linear.com/LTC2499 LT 1114 REV E • PRINTED IN USA  LINEAR TECHNOLOGY CORPORATION 2006
LTC2499CUHF#TRPBF 价格&库存

很抱歉,暂时无法提供与“LTC2499CUHF#TRPBF”相匹配的价格&库存,您可以联系我们找货

免费人工找货