0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AM40EW-11005SH30-NZ

AM40EW-11005SH30-NZ

  • 厂商:

    AIMTEC

  • 封装:

    DIP6 模块

  • 描述:

    DC DC CONVERTER 5V 40W

  • 数据手册
  • 价格&库存
AM40EW-11005SH30-NZ 数据手册
AM40EW-NZ DC-DC Converter Click to ORDER AM40EW-NZ samples This new series AM40EW-NZ provides a wide input voltage range of 40-160VDC required by input voltages of 72V, 96V, 110V in railway industry. Outputs and isolation voltage up to 3000VDC/1500VAC ensure them to meet the railway locomotive EN50155 standard requirements and EN62368 standard requirements. The converters also offer a wide operating temperature range of -40℃ to +85℃. Protections for input UVP, OSC, OCP, OVP and OTP are also included. Housed in 2x1 inch package, this AM40EW-NZ series is available for packages with optional heat sink in PCB mount, chassis mount and DIN rail mount, which offers flexibility to the designer of the end-product and makes this series ideal for applications in railway monitoring, lighting equipment, information display and other railway vehiclerelated equipment. Encapsulated Features • • • • • • Summary Ultra-wide Input: 40 - 160VDC Operating Temp: -40 °C to +85 °C High isolation voltage: 3000VDC/1500VAC Low ripple & noise, 150mV(p-p), typ. Output short circuit, over-current, over-voltage, over temperature protection Regulated Output AM40EW-NZ 6000 48 1500 200 105 105 85 70 3000 55 1000 160 40 3.3 40 40 33 3.3 1 -40 Input voltage (VAC) Output voltage (V) Isolation (VAC) Power (W) Temp. range (℃) Derating (℃) Applications Training Press Release Coming Soon! Power Grid Product Training Video (click to open) F 052e R4 Rev: 11/21/A Industrial Telecom Instrumentation Application Notes www.Aimtec.com 1 AM40EW-NZ DC-DC Converter Models & Specifications Single Output Model AM40EW-11003SH30-NZ AM40EW-11005SH30-NZ AM40EW-11012SH30-NZ AM40EW-11015SH30-NZ AM40EW-11024SH30-NZ AM40EW-11048SH30-NZ Input Voltage (VDC) Output Voltage (VDC) 110 (40 - 160) 110 (40 - 160) 110 (40 - 160) 110 (40 - 160) 110 (40 - 160) 110 (40 - 160) 3.3 5 12 15 24 48 Output Input Current Current max max (mA) (A) 353 423 423 423 423 423 10 8 3.33 2.67 1.67 0.83 Isolation (VDC/VAC) Maximum capacitive Load (µF) 3000/1500 3000/1500 3000/1500 3000/1500 3000/1500 3000/1500 10000 10000 2700 1680 680 470 Efficiency Typ. (%) 85 86 89 89 87 87 Note: Use suffix “-K” for optional heat sink. Use suffix “ST” for chassis and suffix “STD” for DIN-Rail mounting (ex. AM40EW-11005SH30-NZ-K-STD is with the heatsink attached version. AM40EW-11005SH30-NZ-K-STD is DIN-Rail mounting version with the heatsink. AM40EW-11005SH30-NZ-ST is chassis mounting and AM40EW-11005SH30-NZ-STD is DIN-Rail mounting version.) Input Specification Parameters Voltage range Input under voltage lockout Startup voltage Startup time Filter Absolute maximum rating Input reflected ripple current On/Off Control Conditions Typical Nominal 110 40 – 160 ON/OFF Nominal input and resistive load Maximum Units VDC 40/32 40 20 Pi network VDC VDC ms Duration 1s max. 180 VDC 25 mA pk-pk ON – 3.5 to 12Vdc or open; OFF – 0 to 1.2Vdc or Short circuit Pin 1 and Pin 2, idle current 2mA typ. 10mA max. Isolation Specification Parameters Tested I/O voltage Resistance Capacitance F 052e R4 Rev: 11/21/A Conditions Typical 60 sec, leakage of 1mA max. 60 sec, leakage of 5mA max 500Vdc 100KHz/0.1V 3000 1500 >1000 2200 www.Aimtec.com Maximum Units 3000 VDC VAC MOhm pF 2 AM40EW-NZ DC-DC Converter Output Specification Parameters Voltage accuracy Line regulation Load regulation Voltage adjustment Short circuit protection Over current protection Over voltage protection Temperature coefficient Ripple & Noise* Transient recovery time Transient response deviation Conditions Typical Maximum Units 0-100% load Full load, main input range 0-100% load ±1.0 ±0.4 ±0.5 ±3.0 ±1.0 ±1.0 ±10 % % % %Vout Continuous, Auto recovery 110~190 110~160 ±0.02 150 25% load step change 300 3.3V/5V models ±5 25% load step change Others ±3 % of Iout % of Vout %/ oC mV pk-pk µS ±0.03 200 500 ±8 ±5 % * 20MHz bandwidth. The Ripple & Noise may reach 5% of Vout max. when the adding load below 5% of total load. General Specifications Parameters Conditions Switching frequency Operating temperature Storage temperature Over temperature protection Lead temperature Cooling Humidity Case material Full load See derating graph Typical Maximum Units 130 KHz oC oC oC 300 oC 220 -40 to +85 -55 to +125 100 At case 1.5mm from case 10 sec. Free air convection Non-condensing 95 % RH Aluminum PCB mountable models 26 With optional -K heatsink models 34 With optional -ST mounting plate 48 Weight g With optional -STD mounting plate 68 With optional -K-ST mounting plate and heatsink 56 With optional -K-STD mounting plate and heatsink 76 PCB mountable models 2 x 1 x 0.47 inches (50.8 × 25.4 × 11.8 mm) With optional -K heatsink models 2.02 x 1.03 x 0.65 inches (51.4 × 26.2 × 16.5 mm) With optional -ST mounting plate 2.99 x 1,24 x 0.83 inches (76 × 31.5 × 21.2 mm) Dimensions (L x W x H) With optional -STD mounting plate 2.99 x 1,24 x 1.02 inches (76 × 31.5 × 25.8 mm) With optional -K-ST mounting plate and heatsink 2.99 x 1,24 x 1.00 inches (76 × 31.5 × 25.3 mm) With optional -K-STD mounting plate and heatsink 2.99 x 1,24 x 1.18 inches (76 × 31.5 × 29.9 mm) MTBF > 500 000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity
AM40EW-11005SH30-NZ 价格&库存

很抱歉,暂时无法提供与“AM40EW-11005SH30-NZ”相匹配的价格&库存,您可以联系我们找货

免费人工找货