0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
700-AT1

700-AT1

  • 厂商:

    ALLEN-BRADLEY

  • 封装:

  • 描述:

    700-AT1 - Solid-State Relays - Allen-Bradley

  • 数据手册
  • 价格&库存
700-AT1 数据手册
Bulletin 700-SC Solid-State Relays Overview/Product Selection Bulletin 700-SC • • • • • • 3 A (resistive) Max. Continuous Load (Output) Current 264V AC, 48V DC or 125V DC Max. Load Voltage Range Options 5…24V DC or 110/220V AC Control (Input) Voltage Options LED Indicator (Optional) For Input/Logic ON/OFF Status Monitoring 700-HN103, 700-HN104, or 700-HN128 Socket Compatible Compatible with 700-AT1 or 700-AT2 Timer Module Table Of Contents Product Selection . . . . . . . Accessories . . . . . . . . . . . . Specifications . . . . . . . . . . Approximate Dimensions . . . . . . . . . . . . 37 38 39 41 Product Selection Factorystocked Item (Single Pack) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ Input-to-Output Isolation Method Zero Cross Function LED Indicator Rated Output (Load) Max. Current and Voltage Range 3 A @100…240V AC Rated Input Control Voltage 5…24V DC 100/110V AC 200/220V AC 24V DC 5…24V DC 4…24V DC 24V DC 4…24V DC 5…24V DC Cat. No. 700-SCZY3Z25 700-SCZY2A1 700-SCZY2A2 700-SCTY3Z24 700-SCNY3Z25 700-SCZN3Z26 700-SCTN3Z24 700-SCNN3Z26 700-SCNN2Z25 Photocoupler Phototriac Photocoupler Phototriac Yes Yes No No Yes No No 2 A @ 100…240V AC 3 A @100…240V AC 3 A @ 4…48V DC 3 A @ 100…240V AC 3 A @ 4…48V DC 2 A @ 5…110V DC Photocoupler N/A 37 Bulletin 700-SC Solid-State Relays Accessories Description Pkg. Quantity Cat. No. Factory-stocked Item Screw Terminal Socket — Panel or DIN Rail Mounting; Guarded Terminal Construction Order must be in ten or multiples of ten Cat. No. 700-HN103 1 700-HN103 ✔ Cat. No. 700-HN104 Screw Terminal Socket – Panel or DIN Rail Mounting. Guarded Terminal Construction 14-blade miniature socket for use with Bulletin 700-SC relays. This socket has coil and contact separation as well as the ability to plug in optional plug in modules (700-A** accessories: LED, Surge Suppression, Timing Modules) 10 700-HN104 ✔ Screw Terminal Base Socket — Panel or DIN Rail Mounting; Open Style Construction Order must be in multiples of ten Cat. No. 700-HN128 10 700-HN128 ✔ DIN Rail Mounting Pack Standard 35 x 7.5 mm DIN Rail, 1 meter long, 10 rails per package. Order must be for 10 rails or multiples of 10. Cat No. 199-DR1 10 199-DR1 ✔ Pre-printed identification tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays. Blank identification tags — contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays. 10 700-N40 10 700-N41 Retainer Clip Secures relay in socket. Order must be for 10 clips or multiples of 10. 10 700-HN114(B)➊ ✔ Sample Retainer Clips ON-Delay Time Module Voltage Range: 12…24V AC/DC used with 700-HN153 socket One Shot Timing Module Voltage Range: 12…24V AC/DC used with 700-HN153 socket 1 700-AT1 1 700-AT2 ➊ Series B retainer clip must be used with Bulletin 700-SC 38 Bulletin 700-SC Solid-State Relays Specifications Control/Input Ratings Cat. No. 700-SCZY3Z25 700-SCZY2A1 700-SCZY2A2 700-SCTY3Z24 700-SCNY3Z25 700-SCZN3Z26 700-SCTN3Z24 700-SCNN3Z26 700-SCNN2Z25 Rated Control Voltage 5…24V DC 100/110V AC 200/220V AC 24V DC 5…24V DC 4…24V DC 24V DC 4…24V DC 5…24V DC Operating Control Voltage Range 4…28V DC 75…125V AC 150…250V AC 19.2…28.8V DC 4…28V DC 3…28V DC 19.2…28.8V DC 3…28V DC Impedance 15 mA max. ➊ 41 KΩ± 20% 72 KΩ ± 20% 2 KΩ ± 20% 1.5 KΩ + 20%/–10% ➋ 15 mA max. ➊ 2 kΩ ± 20% 1.5 KΩ + 20%/–10% ➋ Load/Output Ratings Cat. No. — 700-SCZY3Z25 700-SCTY3Z24 700-SCZN3Z26 700-SCTN3Z24 700-SCZY2A1 700-SCZY2A2 700-SCNN3Z25 700-SCNY3Z26 700-SCNN2Z25 ➊ ➋ ➌ ➍ 100…240V AC 4…48V DC 5…110V DC 3…52.8V DC 3…125V DC 100…240V AC 75…264V AC 0.1 A 0.1 A 0.1 A 2A 3A 2A 18 A (10 ms) 10 A (10 ms) 0.1 A 3A 45 A (@50/60 Hz, 1 cycle) Rated Load Voltage — Applicable Load Load Voltage Range — Continuous Load Current (Resistive) Min. Max. ➍ Max. Inrush Current ➌ — Control Voltage Levels Pick-up Voltage 4V DC max. 75V AC max. 150V AC max. 19.2V DC max. 4V DC max. 3V DC max. 19.2V DC max. 3V DC max. 1V DC min. Drop-out Voltage 1V DC min. 20V AC min. 40V AC min. With constant current input circuit system. SSR impedance varies with a change in input voltage. Input impedance attains its maximum at the operating voltage. If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. Refer to “Inrush Current Resistivity” graphs on page 40 for details. Refer to the following "Load Current Versus Ambient Temperature Characteristics" graphs on page 40 for additional load current details. Characteristics Cat. No. Load Switching Method/Device 700-SCZ…. Triac 1/2 of load power source + 1 ms max. (DC input) Pick-up Time 3/2 of load power source + 1 ms max. (AC input) 1/2 of load power source + 1 ms max. (DC input) Drop-out Time 3/2 of load power source + 1 ms max. (AC input) Output ON Voltage Drop Output Leakage Current Output VDRM, VCEO (V) Output di/dt (A/uS) Output dv/dt (V/uS) Output I2t (A2S) Output Tj °C Max. Insulation Resistance Dielectric Strength Vibration Resistance (max.) Shock Resistance (max.) Ambient Temperature 1.6 V (RMS) max 5 mA max (@ 100 V AC) 10 mA max (@ 200 V AC) 600 50 250 18 125 1/2 of load power source + 1 ms max 1.6V (RMS) 2.5 mA max (@ 100 V AC) 5 mA max (at 200 V AC) 600 50 250 18 125 100 MΩ min (@ 500V DC) 1,500 V AC, 50/60 Hz for 1 minute 10…55 Hz, 1.5 mm double amplitude (10 G) 1,000 m/s2 (100 G) Operating: -30°C…80°C (-22...176°F) with no icing or condensation Storage: -30°C…100°C (-22...212°F) with no icing or condensation 1 ms max 0.5 ms max 0.5 ms max 700-SCT 700-SCNN3… Transistor 700-SCNN2… 2 ms max 2.5 ms max 1.5 V max. 5 mA max (@ 50 V DC) 1.5V max. 0.1 mA max (@ 100 V DC) 80 — — — 150 80 — — — 150 39 Bulletin 700-SC Solid-State Relays Specifications, Continued Characteristics Standards Ambient Humidity Weight UL508, CSA C 22.2, CE, VDE Operating: 45%…85% (no condensation) Approx. 50 g Load Current Versus Ambient Temperature Characteristics 700-SC_ _3... 700-SC_ _2... Load current (A) Load current (A) Ambient temperature (°C) Ambient temperature (°C) Inrush Current Resistivity➊ 700-SCZ.... 700-SCT... 700-SCNN3... 700-SCNY3 700-SCNN2... Inrush current (A. Peak) Inrush current (A. Peak) Inrush current (A. Peak) 10 20 Energizing time (ms) Energizing time (ms) Energizing time (ms) ➊ Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR. 40 Bulletin 700-SC Solid-State Relays Approximate Dimensions Note: Bulletin 700-SC is compatible with the 700-HN103, 700-HN104, and 700-HN128 sockets. All units in millimeters unless otherwise indicated. Dimensions are not intended for manufacturing purposes. Terminal Arrangement/ Internal Connections (Bottom View) 1 28 max. 5 9 13 – – Cat, No 700-SC… ➊ 4 8(+) Load 12(–) (–) 14 + Input voltage + Load (+) Load power supply 21.5 max. 36.5 max. 42.5 max. Input Note: The plus and minus symbols shown in parentheses are for DC loads. ➊ Bulletin 700-SC is compatible with cat. nos. 700-HN103, -HN104, and -HN128 socket. Basic Application Considerations For Bulletin 700-SC Connection For DC Load Switching, Bulletin 700-SC will operate properly if the load is connected to either the positive or negative SSR load terminal. High-density Mounting of Multiple SSRs If multiple relays are mounted side by side, be aware that the outer wall of each SSR works as a radiator. The SSR casing serves to dissipate heat. Install the relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half. Protective Component When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has built-in surge suppression (Bulletins 700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device . Select a varistor that meets the conditions of the load voltage outlined in the table below. Note: For additional details applying solid-state relays, refer to pub. number 700-AT001A-EN-E, "Solid-State Relay Application Guide." Document available at www.theautomationbookstore.com. Load Voltage 100…120V AC 200…240V AC 380…480V AC Varistor Voltage 240…270 V 440…470 V 820…1000 V 1000 A min. Varistor Surge Resistance 41
700-AT1 价格&库存

很抱歉,暂时无法提供与“700-AT1”相匹配的价格&库存,您可以联系我们找货

免费人工找货