MSR18T

MSR18T

  • 厂商:

    ALLEN-BRADLEY

  • 封装:

  • 描述:

    MSR18T - Monitoring Safety Relays - Allen-Bradley

  • 数据手册
  • 价格&库存
MSR18T 数据手册
Safety Relays Monitoring Safety Relays Minotaur MSR18T Specifications Standards EN 954-1, ISO13849-1, IEC/EN 60204-1, IEC 60947-5-1, ANSI B11.19, AS4024.1, EN 574 Cat. 4 per EN 954-1 (ISO 13849-1) CE marked for all applicable directives, cULus & TÜV 24V AC/DC -20%, +10% 120V AC -15%, +10% 240V AC -15%, +10% 3.6W 6.1VA, 5.7W 1 N.C. or 1 N.C. & 1 N.O. or 2 N.C. 0.5 seconds 100Ω Automatic/Man. or Monitored Man. 5 N.O. Safety; 2 N.C. Auxiliary C300 AC-15 0.75A/250V AC, 1.5A/120V AC Q300 DC-13 2A/24V DC 1 x 8A, 2 x 7A, 3 x 5.5A, 4 x 5A, 5 x 4.5A 20s reset time 1.6 slow blow 24V AC/DC, 20mA 20ms Red = Input Short Green = Power Green = Run Red = Input Fault Red = Output Fault 3000V C in accordance with VDE 0110 2 -25°C to +55°C (-13°F to +131°F) 95% RH IP40, (NEMA 1), DIN 0470 IP20, DIN 0470 1 x 2.5mm2 (14AWG) 0.8N⋅m (7lb⋅in) Red Polyester PBT 35mm DIN rail 395g (0.87lbs) 100,000 operations 500,000 operations 1,000,000 operations 2,000,000 operations 5,000,000 operations 0.75mm (0.30in) peak, 10-55Hz 5g, 11ms half sine Category Approvals Power Supply AZ1 and AZ2 AZ1 AZ2 Power Consump. 24V AC/DC 120V and 240V AC Safety Inputs Description The Minotaur MSR18T is a monitoring safety relay unit with dual channel input, 5 safety outputs and 2 auxiliary outputs. It is designed for operation as E-Stop, safety gate applications, and 2-hand control applications. The MSR18T is a versatile unit with extensive diagnostics. It can be used with E-Stop buttons, gate interlocks, two-hand controls as well as expansion relays when additional inputs are needed. When used in a suitably configured circuit, the MSR18T provides additional safety rated output circuits with checking and monitoring of its status. Safety critical faults or power failures will cause them to initiate a lock-out to a safe state. Input Simultaneity Maximum Input Resistance Reset Outputs ➊ Output Utilization per IEC 60947-5-1 (Inductive) Thermal Current (non switching) Fuses Input (internal elect.) Output (external) Min. Switched Current/Voltage Maximum Dropout Time Indication LEDs Features • • • • • • • • • Category 4 per EN 954-1 Stop category 0 24V AC/DC and 110V AC or 240V AC Dual channel inputs 5 N.O. safety outputs 2 N.C. auxiliary outputs E-Stop and gate applications 2-hand control applications 5 LEDs for comprehensive diagnostics Impulse Withstand Voltage Installation Group Pollution Degree Operating Temperature Humidity Enclosure Protection Terminal Protection Conductor Size Torque Settings—term. screws Case Material Mounting Weight Electrical Life 222V AC/4A/880VA cosϕ=0.35 220V AC/1.7A/375VA cosϕ=0.6 30V DC/2A/60W 10V DC/0.01A/0.1W Mechanical Life Vibration Shock ➊ See Output Ratings on page 1-29 for details. Consult factory for ratings not shown. 4-18 Safety Relays Monitoring Safety Relays Minotaur MSR18T Product Selection Inputs 1 N.C. or 1 N.C. & 1 N.O. or 2 N.C. Safety Outputs 5 N.O. Auxiliary Output 2 N.C. Power Supply 24V AC/DC and 120V AC 24V AC/DC and 240V AC Catalogue Number 440R-ZBR520AZ1 440R-ZBR520AZ2 Dimensions—mm (inches) Block Diagram 103 (4.06) 90 (2.34) A1 A2 B1 T11 T32 T12 T31 T34 IF1 K3 K2 T22 T35 13 23 33 43 53 61 73 PTC 97 (3.82) ~ Logic 24V DC Input Short Power Output Fault Run K1 K1 K2 K3 Input Fault B2 X1 X2 T33 14 24 34 44 54 62 74 Typical Wiring Diagrams 24V DC open L1 L2 L3 T11 T12 X1 X2 T22 T35 A1 B1 13 23 33 43 53 61 73 24V DC L1 L2 L3 open T11 T12 X1 X2 T22 T35 A1 B1 13 23 33 43 53 61 73 K1 K1 closed MSR18T MSR18T K2 closed T31 T32 IF1 T33 T34 A2 B2 14 24 34 44 54 62 74 T31 T32 IF1 T33 T34 A2 B2 14 24 34 44 54 62 74 Reset Ground K1 Aux M Ground K1 K2 Aux M Single-Channel Input, Monitored Manual Reset, Single-Channel Output, Monitored Output L Dual-Channel Input 1 N.O. & 1 N.C., Automatic Reset, Dual-Channel Output, No Monitored Output L open L1 L2 L3 L1 L2 L3 T11 T12 X1 X2 T22 T35 A1 B1 13 23 33 43 53 61 73 Switch 1 T11 T12 X1 X2 T22 T35 A1 B1 13 23 33 43 53 61 73 K1 K1 Switch 2 MSR18T K2 T31 T32 IF1 T33 T34 A2 B2 14 24 34 44 54 62 74 closed MSR18T K2 T31 T32 IF1 T33 T34 A2 B2 14 24 34 44 54 62 74 K1 K2 Aux M Reset N K1 K2 Aux M N Two-Hand Control, Automatic Reset, Dual-Channel Output, No Monitored Output Dual-Channel Input (2 N.C.), Monitored Manual Reset, Dual-Channel Output, Monitored Output 4-19
MSR18T 价格&库存

很抱歉,暂时无法提供与“MSR18T”相匹配的价格&库存,您可以联系我们找货

免费人工找货