0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MSR211P

MSR211P

  • 厂商:

    ALLEN-BRADLEY

  • 封装:

  • 描述:

    MSR211P - Modular Monitoring Safety Relays - Allen-Bradley

  • 数据手册
  • 价格&库存
MSR211P 数据手册
Safety Relays Modular Monitoring Safety Relays Minotaur MSR211P Category Power Supply Power Consumption Safety Inputs Input Simultaneity Max. Input Resistance Inputs Reset Reset Outputs Cat. 4 per EN954-1 (ISO13849-1) 24V DC; 0.8 to 1.1 x rated voltage 8W 1 N.C., 2 N.C., light curtain Infinite 1300ohms 3200ohms Monitored Man. or Auto./Man. 2 N.O. safety; 1 N.C. auxiliary 1 SS PNP Inputs Closed 1 SS PNP Outputs Active AC-1: 6A/250V AC DC-1: 6A/24V DC B300, AC-15; 3A/250V AC, 3A/125VAC P300, DC-13; 2.5A/24V DC 1x6A, 2x4A 20mA @ 30V DC 6A slow blow or 10A quick blow 10mA/10V DC AgSnO2 with 2 micron gold plating Gold plated 3s 25ms 30ms+2.4ms per MSR221 40-145 ms, depending on expansion modules used Green = Input 1 closed Red = Input 1 open Green = Input 2 closed Red = Input 2 open Green = CH1 output active Green = CH2 output active Green = Power Green = Run (outputs active) Red = Stop (outputs off) + diagnostics Amber = Ready (inputs closed) 2500V 2 -5°C to +55°C (+23°F to 131°F) 90% RH IP40 (NEMA 1) IP20 Input; SS outputs 0.2–4mm2 (24–12 AWG) 0.4–0.5 Nm (3.54–4.43lb•in) Polyamide PA 6.6 35mm DIN rail 280g (0.62lbs) 100,000 operations 500,000 operations 1,000,000 operations 2,000,000 operations 2,000,000 cycles 10-55 Hz, 0.35mm 10g, 16ms, 100 shocks Output Utilization per IEC 60947-4-1 (Resistive) Description The MSR211P forms one of the base units for the modular Minotaur MSR200 family of monitoring safety relays. It can be combined with other modules of the MSR200 Series to configure a safety control system with numbers of inputs and outputs matching users’ specific application requirements, as well as diagnostic and networking capabilities. Up to 10 input modules and 2 output modules can be connected to one base unit by simply removing the terminator, included with each base unit, and connecting the ribbon cables of the neighboring module. The terminators must be inserted into the final input and output modules. The MSR211P has two inputs. Each input can be wired in one of three ways: 1N.C., 2 N.C., or 2 PNP connections from a light curtain. The MSR211P does not perform cross fault monitoring, and would not detect a short across the inputs of a 2 N.C. input. When connected to light curtains, the light curtain must perform the cross fault detection. The MSR211P has the capability to perform external device monitoring (EDM). The EDM capability works in conjunction with the reset option. The user selects EDM and the reset function by jumpers across terminals Y40, Y41 and Y42. The MSR211P has two semiconductor outputs designed to send status information to a PLC. Terminal Y33 indicates the inputs are closed (the Ready LED is on). Terminal Y32 indicates the outputs are active. The outputs include 2 normally open safety rated outputs and 1 normally closed auxiliary output. The safety outputs have independent and redundant internal contacts to help ensure the safety function. ➊ Output Utilization per IEC 60947-5-1 (Inductive) Thermal Current (non switching) Output, Solid State Fuses Output (external) Min. Switched Current/Voltage Contact Material Ribbon Cable Contacts Power On Delay Response Time MSR211 MSR211+ MSR221 Recovery Time Indication LEDs Impulse Withstand Voltage Pollution Degree Operating Temperature Humidity Enclosure Protection Terminal Protection Short Circuit Protection Conductor Size Torque Settings—term. screws Case Material Mounting Weight Electrical Life 222V AC/4A/880VA cosϕ=0.35 220V AC/1.7A/375VA cosϕ=0.6 30V DC/2A/60W 10V DC/0.01A/0.1W Mechanical Life Vibration Shock Features • • • • • • • • Category 4 per EN 954-1 Stop category 0 2 Input circuits: light curtain, gate, or E-Stop inputs 2 Safety outputs, 1 auxiliary output 2 Solid state outputs 10 Diagnostic LEDs Monitored or automatic reset Removable terminals Specifications Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-4-1, IEC 60947-5-1, ANSI B11.19, AS4024.1 C-Tick, CE marked for all applicable directives, cULus & TUV Approvals ➊ See Output Ratings on page 1-29 for details. Consult factory for ratings not shown. 4-74 Safety Relays Modular Monitoring Safety Relays Minotaur MSR211P Product Selection Inputs Two Inputs 1 N.C. or 2 N.C. or Light Curtain Safety Outputs 2 N.O. Auxiliary Outputs 1 N.C. Solid State Outputs 2 Power Supply 24V DC Catalogue Number 440R-H23177 Dimensions—mm (inches) Block Diagram 99 (3.89) 45 (1.77) S12 S11 S20 S21 S32 S31 S51 S41 13 Y40 23 31 13 23 Y41 Y42 33 A1 K1 114.5 (4.5) Y1 S42 Y2 S50 K2 14 24 32 Y31 Y32 Y33 S34 S62 Y31 Y32 Y33 Y30 14 24 A2 32 Typical Wiring Diagrams +24V DC Termination or Expansion Cable Termination or Expansion Cable Termination or Expansion Cable Light Curtain Out 1 Out 2 +24V DC Termination or Expansion Cable Light Curtain Out 1 Out 2 A1 S12 S32 Y31 Y40 Y41 Y42 13 23 31 L1 L2 L3 A1 S12 S32 Y31 Y40 Y41 Y42 13 23 31 L1 L2 L3 MSR211P Safety Gate K1 K2 Safety Gate K1 MSR211P K2 A2 S42 S62 Y30 Y32 Y33 S34 Y1 Y2 14 24 32 K1 K2 Reset Ground Output Active Inputs Closed A2 S42 S62 Y30 Y32 Y33 S34 Y1 Y2 14 24 32 K1 K2 M M Closed Ground Output Active Inputs Closed Reset Closed Light Curtain and Dual Channel Safety Gate, Monitored Manual Reset, Monitored Output +24V DC Termination or Expansion Cable Termination or Expansion Cable Light Curtain Out 1 Out 2 Light Curtain and Single Channel Safety Gate, Monitored Manual Reset, No Monitoring Output A1 S12 S32 Y31 Y40 Y41 Y42 13 23 31 L1 L2 L3 MSR211P Safety Gate K1 K2 A2 S42 S62 Y30 Y32 Y33 S34 Y1 Y2 14 24 32 K1 K2 M Closed Ground Output Active Inputs Closed Light Curtain and Dual Channel Safety Gate, Automatic Reset, Monitored Output Diagnostics – Red Stop LED blinks Blink Rate 2 3 Continuous Description Change in Y40/Y41/Y42 circuit during operation. Fault in external feedback circuit Y1-Y2. Clear fault and cycle power to reset the module. Internal fault in base or expansion module 4-75
MSR211P 价格&库存

很抱歉,暂时无法提供与“MSR211P”相匹配的价格&库存,您可以联系我们找货

免费人工找货