0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
LX200

LX200

  • 厂商:

    ARTESYN(雅特生)

  • 封装:

  • 描述:

    LX200 - Flexible single and muliple outputs - Artesyn Technologies

  • 数据手册
  • 价格&库存
LX200 数据手册
LX200 SERIES Flexible single and muliple outputs • • • • • • • 200W continuous, 300W peak output power Industry standard footprint, low profile Conducted noise to meet EN55022 class B AC and DC input voltage options in same package Efficiency up to 88% Optional power sharing/VME signals board Autoranging input option [ 2 YEAR WARRANTY ] The LX200 series offers 200 Watts of continuous output power in a low profile industry standard footprint. With two single output options and a flexible multiple output version, the series can address most power requirements as standard. The design is specifically tailored to allow full flexibility and modifications to meet customer applications can be implemented with relative ease. The LX200 AC input series meets the safety requirements of EN60950, VDE0805, UL1950 and CSA C22.2 No. 950. Input conducted noise levels meet the requirements of FCC and EN55022 class B. LX200 series power supplies are ideal for use in applications such as point-of-sale equipment, central and public telecom power systems and network equipment. SPECIFICATION OUTPUT SPECIFICATIONS Voltage adjustability Remote sense Line regulation (LL to HL, FL) Load regulation (20% to 100% FL) All specifications are typical at nominal input, full load at 25°C unless otherwise stated ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS -8%/+16% ±20% ±10% Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity EN55022, level A EN55022, level B EN61000-4-2, level EN61000-4-2, level EN61000-4-5, level EN61000-4-4, level EN61000-4-3, level EN61000-4-6, level Vout on singles +5V output on multiple Single outputs Multiple: +5V output Multiple: aux. outputs, Note 5 Single outputs: Multiple: +5V output Multiple: -5V output Multiple: ±12V, 24V, Note 5 5A load step on main output Auxiliary outputs, Note 5 25% di/dt ±0.2% ±0.2% ±0.5% ±0.2% ±1.0% ±4.0% ±2.0% 1.0% 3 4 3 3 3 3 Perf. Perf. Perf. Perf. Perf. Perf. criteria criteria criteria criteria criteria criteria 1 1 1 1 2 2 GENERAL SPECIFICATIONS Hold-up time Efficiency 110/230VAC 28ms 82% min. Input/output Input/chassis Fixed 3000VAC 1500VAC 44kHz Cross regulation Transient response Isolation voltage Switching frequency Approvals and standards Weight 1% max. dev., 1ms recov. ±0.02%/°C ±0.04%/°C EN60950, VDE0805, UL1950 See Note 7 CSA C22.2 No. 950 1.3kg (46oz) Temperature coefficient Main/single output Multiple: auxiliary outputs Overvoltage protection Output power limit Main/single output 130% ±10% Vout Multiples: 300W Pout primary power limited Singles: 105%-120% Iout current foldback All outputs Yes ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating 0°C to +70°C Non-operating –25°C to +85°C 0°C to +40°C ambient, 200W convection cooled 40°C to 70°C ambient, Derate linearly convection cooled to 25% full load Peak (0°C to 40°C, max. 10s) 300W Non-condensing Operating Non-operating 5% to 95% RH 10,000 feet max. 30,000 feet max. Short circuit protection INPUT SPECIFICATIONS Input voltage range See Note 3 LX200-46xx models, 175 to 264VAC (230VAC version) LX200-76xx models, 98 to 132VAC autorange version 190 to 264VAC Drop-out voltage 90VAC 50Hz/60Hz 25A max. 115VAC, 60Hz 230VAC, 50Hz 1.6mA 2.5mA Logic 0 on ROF Vibration Relative humidity Altitude Input frequency Input surge current Safety ground leakage current Remote OFF Operating, 5–50Hz 0.05mm pk-pk Operating, 50–100Hz 0.025mm pk-pk Non-operating 100mm drop on chassis face PAGE 1 AC/DC POWER SUPPLIES | 200W AC 200 Watt AC/DC universal input switch mode power supplies OUTPUT VOLTAGE +5.0V –5.0V –12.0V +12.0V +24.0V 24.0V 48.0V (4) (4) OUTPUT CURRENTS MAX (1) RIPPLE RMS 0.2% 0.2% 0.2% 0.2% 0.2% 0.1% 0.1% PK-PK 2.0% 2.0% 2.0% 2.0% 2.0% 1.0% 1.0% MODEL NUMBER 230VAC LX200-4620 (3) PEAK (2) AUTORANGE LX200-7620 20.0A 4.0A 4.0A 8.0A 4.0A 9.0A 4.5A 40.0A 10.0A 10.0A 20.0A 10.0A – – LX200-4624 LX200-4617 LX200-7624 LX200-7617 PIN CONNECTIONS PIN NO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 INPUT Earth N/C Neutral N/C Live N/C 115V Link N/C N/C N/C N/C N/C N/C N/C MULTI O/P SINGLE O/P PS ACF SRS ROF +5VS +5V +5V +5V 0V 0V 0V –5V –12V +12V +24V PS ACF SRS ROF 0VS 0V 0V 0V 0V 0V +Vout +Vout +Vout +Vout +VS SIGNALS SRS ACF DCF PM PS ROF +VS 0V – – – – – – Notes 1 The multiple output LX200 has a continuous output power rating of 200W. The single-output versions have a continuous output power rating of 216W. Peak power figures for individual outputs on the multiple output unit are for less than 10 seconds duration. The overall peak power for the unit is 300W for 10 seconds duration. The LX200 is available with a standard 230VAC input operation (order LX200-46xx) or the input board can be fitted with an autorange circuit which automatically senses the input voltage and switches to the appropriate voltage range (order LX200-76xx). Single output models are adjustable -8%, +16%. A 10% load on the main output is necessary to maintain regulation on the auxiliaries at full load (multiple output model). This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. Consideration should be given to measuring the temperature on the main transformer (T1) when the power supply is installed in end-use equipment. The measured temperature on T1 must not exceed 90°C. For further information on the LX200 safety approvals, contact Computer Products. 2 3 4 5 6 7 Options • • DC input models for 24V and 48V operation are detailed on the LX200, LX350 and LX550 series DC/DC converter data sheet on page 170. A cover and signals board are available as options. To order, add the suffixes ‘-C’, ‘-S’ respectively, see table below. – OPTIONS SUFFIX -C -S -C-S EXAMPLE LX200-76xx LX200-76xx-C LX200-76xx-S LX200-76xx-C-S OVERLOAD/SHORT CIRCUIT PROTECTION The overload/short circuit protection mechanisms are different for the single output models and the multiple output model. The single output models will current limit when the output load reaches 105-120% of maximum load during overload or short circuit conditions. The unit will operate in a constant current mode making the single output models suitable for battery charging applications. The multiple output model uses a power limiting function. When the total output power reaches 300W the outputs will foldback to the values detailed below: Output +5V +12V +24V –5V/–12V Foldback Value 15A continuous 4A continuous 2A continuous Protected by 4A Multi Fuse™ None Cover Signals Cover and Signals SIGNALS (OPTIONAL) An optional signals board supplies the following VME utility bus signals: ACF (AC Fail) Logic 1 to 0 transition occurs >10ms before outputs fall below 80%-85% of nominal in the event of input failure. DCF (DC Fail) Logic 0 occurs if output falls below 85%–95% of nominal. SRS (System Reset) Logic 1 for system OK (AC and DC good and reset times [200ms]) PM Power Monitor signal, proportional to the output power, ratio of 20mV/W ±10%. PS Power Share connections, to be joined for parallel operation of two or more units, ensuring equal power share. For power share operation unit outputs need to be set to ±5% of each other and should be connected in star configurations with the load as star centre. The outputs will not foldback until the total output power exceeds the maximum power limits. This allows the units to have a peak power capability but it requires that care must be taken not to permanently overload any individual output. The +5V, +12V and +24V outputs are not individually protected and it is recommended that the maximum continuous load does not exceed the value given in the output specifications. The -5V and -12V outputs are individually protected by a 4A Multi Fuse™ and the maximum continuous load should not exceed the value given in the output specifications. http://www.artesyn.com PAGE 2 AC/DC POWER SUPPLIES | 200W AC 200 Watt AC/DC universal input switch mode power supplies Mechanical notes A Input and output connectors are 15 way terminal block, 5mm pitch. Signals board option is 8 way, single row right angle 0.1”, Molex 910210128, this mates with 90147 1108 or equivalent. B Customer fixing screws (A) are M3 isometric. They must not penetrate into unit by more than 5mm. 1 INPUT SYSTEM O. K. LED 15 SIGNALS 1 8 1 OUTPUT 15 9.18 (233.2) A A 1.25 (31.75) 6.27 (159.3) A A 1.25 (31.75) A A 1.02 (25.9) .42 (10.7) 7.15 (181.6) 8.52 (216.4) 0.59 0.83 2.05 (52) A A A A ALL DIMENSIONS IN INCHES (mm) DERATING CURVE (See Notes 1 & 2) Output Power (Watts) 300W PEAK OUTPUT POWER 200W International Safety Standard Approvals Multiple output and 24V Single output units are approved to these standards. Safety approval pending for 48V output model. See Note 7 EN60950/VDE0805 Reg. File No. 90371 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C/LR101320 0W NATURAL CONVECTION COOLING 50W 10% MIN. LOAD FOR AUXILIARY REGULATION 0°C 10°C 20°C 30°C 40°C (15) 50°C (21) 2.06 (52.4) 60°C 70°C PAGE 3 DS_LX200AC_19980401.PDF Data Sheet © Artesyn Technologies® 2000 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. http://www.artesyn.com PAGE 4
LX200 价格&库存

很抱歉,暂时无法提供与“LX200”相匹配的价格&库存,您可以联系我们找货

免费人工找货