AZ900-1C-48D

AZ900-1C-48D

  • 厂商:

    AZETTLER

  • 封装:

  • 描述:

    AZ900-1C-48D - 30 AMP HEAVY DUTY POWER RELAY - American Zettler, Inc.

  • 数据手册
  • 价格&库存
AZ900-1C-48D 数据手册
AZ900 30 AMP HEAVY DUTY POWER RELAY FEATURES • • • • 1 Form C contacts, 2 Form C contacts AC and DC coils available UL Class F (155°C) molded construction UL, CUL file E44211 CONTACTS Arrangement Ratings SPDT (1 Form C) DPDT (2 Form C) Resistive load: Max. switched power: 840 W or 12000 VA Max. switched current: 30 A Max. switched voltage: 600 VAC, 28 VDC 30 A at 240 VAC 1.5 HP at 120 VAC 2.0 HP at 240 VAC 3600 VA at 120 VAC / 240 VAC ballast 30 A at 240 VAC Res., 100k cycles 20 A at 600 VAC 30 A at 28 VDC Silver cadmium oxide < 50 milliohms initially (24 V, 1 A voltage drop method) GENERAL DATA Life Expectancy Mechanical Electrical Operate Time (typical) Release Time (typical) Dielectric Strength (at sea level for 1 min.) Minimum operations 1 x 107 1 x 105 at 30 A 240 VAC Res. 30 msec at nominal coil voltage 30 msec at nominal coil voltage (without suppression) 2200 Vrms contact to contact 2200 Vrms contact to coil 100 megohms min. at 20°C, 500 VDC 50% RH DC: > 10% of nominal coil voltage AC: > 20% of nominal coil voltage -45°C (-49°F) to 80°C (176°F) AC coil, 30A -45°C (-49°F) to 115°C (239°F) DC coil, 30A 227 grams UL, CUR Insulation Resistance Dropout Ambient Temperature Operating Weight Material Resistance COIL Power At Pickup Voltage (typical) Max. Continuous Dissipation Temperature Rise Max. Temperature DC: 1.12 mW AC: 6.9 VA DC: 3.3 W at 20°C AC: 12.5 VA at 20°C 70°C at nominal coil voltage (AC) 35°C at nominal coil voltage (DC) 155°C (311°F) NOTES 1. All values at 25°C (77°F). 2. Relay may pull in with less than “Must Operate” value. 3. Specifications subject to change without notice. 9/12/05 AZ900 RELAY ORDERING DATA COIL SPECIFICATIONS – DC Coil Nominal Coil VDC 6 12 24 48 110 Nominal Coil VAC 6 12 24 120 240 480 Must Operate VDC 4.50 9.1 18.0 36.0 82.5 Must Operate VAC 5.1 10.2 20.4 102.0 204.0 408.0 Max. Continuous VDC 7.8 15.4 32.0 62.6 143.0 Max. Continuous VAC 6.9 13.8 27.6 138.0 276.0 552.0 Nominal Current mA ± 10% 333 166 83 42 18.2 Nominal Coil Power VA 9.5 9.5 9.5 9.5 9.5 9.5 Coil Resistance ± 10% 18 72 290 1150 6050 Coil Resistance ± 10% 0.85 2.85 11.5 295.0 1170.0 4860.0 ORDER NUMBER* AZ900–1C–6D AZ900–1C–12D AZ900–1C–24D AZ900–1C–48D AZ900–1C–110D COIL SPECIFICATIONS – AC Coil 50/60 Hz ORDER NUMBER* AZ900–1C–6A AZ900–1C–12A AZ900–1C–24A AZ900–1C–120A AZ900–1C–240A AZ900–1C–480A *For double pole version replace ‘-1C’ with ‘-2C.’ MECHANICAL DATA WIRING DIAGRAM 8 6 4 7 5 3 1 2 2 Form C 7 5 3 1 2 1 Form C 2 Form C 1 Form C Dimensions in inches with metric equivalents in parentheses. Tolerance: ± .010" 9/12/05
AZ900-1C-48D 价格&库存

很抱歉,暂时无法提供与“AZ900-1C-48D”相匹配的价格&库存,您可以联系我们找货

免费人工找货