Product
Folder
Order
Now
Support &
Community
Tools &
Software
Technical
Documents
ISO5451
SLLSEO1C – JUNE 2015 – REVISED JANUARY 2017
ISO5451 High-CMTI 2.5-A and 5-A Isolated IGBT, MOSFET Gate Driver
With Active Protection Features
1 Features
2 Applications
•
•
1
•
•
•
•
•
•
•
•
•
•
•
•
•
•
50-kV/μs Minimum and 100-kV/μs Typical
Common-Mode Transient Immunity (CMTI)
at VCM = 1500 V
2.5-A Peak Source and 5-A Peak Sink Currents
Short Propagation Delay: 76 ns (Typ),
110 ns (Max)
2-A Active Miller Clamp
Output Short-Circuit Clamp
Fault Alarm upon Desaturation Detection is
Signaled on FLT and Reset Through RST
Input and Output Under Voltage Lock-Out (UVLO)
with Ready (RDY) Pin Indication
Active Output Pull-down and Default Low Outputs
with Low Supply or Floating Inputs
3-V to 5.5-V Input Supply Voltage
15-V to 30-V Output Driver Supply Voltage
CMOS Compatible Inputs
Rejects Input Pulses and Noise Transients
Shorter Than 20 ns
Operating Temperature: –40°C to +125°C
Ambient
Isolation Surge Withstand Voltage 10000-VPK
Safety-Related Certifications:
– 8000-VPK VIOTM and 1420-VPK VIORM
Reinforced Isolation per DIN V VDE V 0884-10
(VDE V 0884-10):2006-12
– 5700-VRMS Isolation for 1 Minute per UL 1577
– CSA Component Acceptance Notice 5A, IEC
60950–1 and IEC 60601–1 End Equipment
Standards
– TUV Certification per EN 61010-1 and EN
60950-1
– GB4943.1-2011 CQC Certification
Isolated IGBT and MOSFET Drives in:
– Industrial Motor Control Drives
– Industrial Power Supplies
– Solar Inverters
– HEV and EV Power Modules
– Induction Heating
3 Description
The ISO5451 is a 5.7-kVRMS, reinforced isolated gate
driver for IGBTs and MOSFETs with 2.5-A source
and 5-A sink current. The input side operates from a
single 3-V to 5.5-V supply. The output side allows for
a supply range from minimum 15 V to maximum 30
V. Two complementary CMOS inputs control the
output state of the gate driver. The short propagation
time of 76 ns assures accurate control of the output
stage.
An internal desaturation (DESAT) fault detection
recognizes when the IGBT is in an overload
condition. Upon a DESAT detect, the gate driver
output is driven low to VEE2 potential, turning the
IGBT immediately off.
Device Information(1)
PART NUMBER
ISO5451
PACKAGE
BODY SIZE (NOM)
SOIC (16)
10.30 mm × 7.50 mm
(1) For all available packages, see the orderable addendum at
the end of the data sheet.
Functional Block Diagram
VCC2
VCC1
VCC1
UVLO1
UVLO2
500 µA
DESAT
IN±
Mute
9V
IN+
GND2
VCC1
VCC2
RDY
Gate Drive
and
Encoder
Logic
Ready
OUT
VCC1
FLT
Q
S
Q
R
VCC1
Decoder
2V
Fault
CLAMP
RST
GND1
VEE2
Copyright © 2016, Texas Instruments Incorporated
1
An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications,
intellectual property matters and other important disclaimers. PRODUCTION DATA.
ISO5451
SLLSEO1C – JUNE 2015 – REVISED JANUARY 2017
www.ti.com
Table of Contents
1
2
3
4
5
6
7
Features ..................................................................
Applications ...........................................................
Description .............................................................
Revision History.....................................................
Description (continued).........................................
Pin Configuration and Function ...........................
Specifications.........................................................
7.1
7.2
7.3
7.4
7.5
7.6
7.7
7.8
7.9
7.10
7.11
7.12
8
9
1
1
1
2
4
4
5
Absolute Maximum Ratings ...................................... 5
ESD Ratings.............................................................. 5
Recommended Operating Conditions....................... 5
Thermal Information .................................................. 6
Power Ratings........................................................... 6
Insulation Characteristics .......................................... 7
Safety-Related Certifications..................................... 8
Safety Limiting Values .............................................. 8
Electrical Characteristics........................................... 9
Switching Characteristics ...................................... 10
Insulation Characteristics Curves ......................... 11
Typical Characteristics .......................................... 12
Parameter Measurement Information ................ 18
Detailed Description ............................................ 20
9.1
9.2
9.3
9.4
Overview .................................................................
Functional Block Diagram .......................................
Feature Description.................................................
Device Functional Modes........................................
20
20
21
22
10 Application and Implementation........................ 23
10.1 Application Information.......................................... 23
10.2 Typical Applications .............................................. 23
11 Power Supply Recommendations ..................... 31
12 Layout................................................................... 31
12.1 Layout Guidelines ................................................. 31
12.2 PCB Material ......................................................... 31
12.3 Layout Example .................................................... 31
13 Device and Documentation Support ................. 32
13.1
13.2
13.3
13.4
13.5
13.6
Documentation Support ........................................
Receiving Notification of Documentation Updates
Community Resources..........................................
Trademarks ...........................................................
Electrostatic Discharge Caution ............................
Glossary ................................................................
32
32
32
32
32
32
14 Mechanical, Packaging, and Orderable
Information ........................................................... 32
4 Revision History
NOTE: Page numbers for previous revisions may differ from page numbers in the current version.
Changes from Revision B (December 2015) to Revision C
Page
•
Changed the title of the data sheet from Active Safety Features to Active Protection Features ........................................... 1
•
Changed Safety and Regulatory Certifications From: CSA Component Acceptance Notice 5A, IEC 60950–1 and IEC
60601–1 and IEC 61010-1 End Equipment Standards To: CSA Component Acceptance Notice 5A, IEC 60950–1
and IEC 60601–1 End Equipment Standards ........................................................................................................................ 1
•
Changed Safety and Regulatory Certifications From: CQC Certification per GB4943.1-2011 To: GB4943.1-2011
CQC Certification.................................................................................................................................................................... 1
•
Changed Safety and Regulatory Certifications From: All Certifications are Planned To: All Certifications Complete
per UL, VDE, CQC, TUV and Planned for CSA ..................................................................................................................... 1
•
Changed the CSA status from planned to certified ................................................................................................................ 8
•
Changed the certifications in the Safety-Related Certifications table..................................................................................... 8
•
Added Reinforced High-Voltage Capacitor Life Time Projection to Safety and Insulation Characteristics Curves ............. 11
•
Changed the second paragraph of Typical Applications ..................................................................................................... 23
•
Added text "and RST input signal" to the Design Requirements ........................................................................................ 24
•
Changed the PCB Material section ...................................................................................................................................... 31
•
Added the Receiving Notification of Documentation Updates section ................................................................................. 32
•
Changed the Electrostatic Discharge Caution section ......................................................................................................... 32
Changes from Revision A (June 2015) to Revision B
Page
•
Changed Features, Safety and Regulatory Approvals From: 6000 VPK To: 8000 VPK .......................................................... 1
•
Changed Features, Safety and Regulatory Approvals From: 4250 VRMS To: 5700 VRMS ..................................................... 1
•
Added the Power Rating table ............................................................................................................................................... 6
•
Moved Insulation Characteristics to the Specifications section.............................................................................................. 7
2
Submit Documentation Feedback
Copyright © 2015–2017, Texas Instruments Incorporated
Product Folder Links: ISO5451
ISO5451
www.ti.com
SLLSEO1C – JUNE 2015 – REVISED JANUARY 2017
•
Changed the Test Conditions and values for qpd in Insulation Characteristics ...................................................................... 7
•
Changed RIO Test conditions From: 100°C ≤ TA ≤ max To: 100°C ≤ TA ≤ 125°C in Insulation Characteristics..................... 7
•
Changed RIO Test conditions From: TS To: TS = 150°C in Insulation Characteristics............................................................ 7
•
Changed the Safety-Related Certifications table.................................................................................................................... 8
•
Moved Safety-Related Certifications to the Specifications section ........................................................................................ 8
•
Moved Safety Limiting Values to the Specification section .................................................................................................... 8
•
Added Note 1 to IIH in the Electrical Characteristics table ..................................................................................................... 9
•
Added Note 2 to IIL in the Electrical Characteristics table ..................................................................................................... 9
•
Changed Thermal Derating Curve for Safety Limiting Current per VDE and Added Thermal Derating Curve for
Safety Limiting Power per VDE ........................................................................................................................................... 11
•
Added ICC1 Supply Current vs Temperature to Blanking Capacitor Charging Current vs Temperature............................... 13
•
Added text ", but connecting CLAMP output of the gate driver to the IGBT gate is also not an issue." to Supply and
Active Miller Clamp............................................................................................................................................................... 21
•
Deleted ground symbol on pin 11 of Global Shutdown with Inverting Input Configuration .................................................. 27
•
Deleted ground symbol on pin 11 on the inverting input of Auto Reset for Non-inverting and Inverting Input
Configuration ........................................................................................................................................................................ 27
•
Changed Normal Operation - Bipolar Supply and Normal Operation - Unipolar Supply ..................................................... 30
Changes from Original (June 2015) to Revision A
Page
•
Changed from a 1-page Product Preview to the full datasheet. ........................................................................................... 1
•
Changed Features, Safety and Regulatory Approvals From: 8000 VPK VIOTM and 2121 VPK To: 6000 VPK VIOTM and
1420 VPK ................................................................................................................................................................................ 1
•
Changed Features, Safety and Regulatory Approvals From: 5.7 kVRMS To: 4250 VRMS ....................................................... 1
•
Changed the Applications list ................................................................................................................................................ 1
•
Moved Safety and Insulation Characteristics Curves to the Specifications ......................................................................... 11
Submit Documentation Feedback
Copyright © 2015–2017, Texas Instruments Incorporated
Product Folder Links: ISO5451
3
ISO5451
SLLSEO1C – JUNE 2015 – REVISED JANUARY 2017
www.ti.com
5 Description (continued)
When desaturation is active, a fault signal is sent across the isolation barrier, pulling the FLT output at the input
side low and blocking the isolator input. The FLT output condition is latched and can be reset through a lowactive pulse at the RST input.
When the IGBT is turned off during normal operation with bipolar output supply, the output is hard clamp to VEE2.
If the output supply is unipolar, an active Miller clamp can be used, allowing Miller current to sink across a low
impedance path, preventing IGBT to be dynamically turned on during high voltage transient conditions.
The readiness for the gate driver to be operated is under the control of two undervoltage-lockout circuits
monitoring the input side and output side supplies. If either side has insufficient supply the RDY output goes low,
otherwise this output is high.
The ISO5451 is available in a 16-pin SOIC package. Device operation is specified over a temperature range from
–40°C to +125°C ambient.
6 Pin Configuration and Function
DW Package
16-Pin SOIC
Top View
1
16
GND1
DESAT
2
15
VCC1
GND2
3
14
RST
NC
4
13
FLT
VCC2
5
12
RDY
OUT
6
11
IN-
CLAMP
7
10
IN+
VEE2
8
9
ISOLATION
VEE2
GND1
Pin Functions
PIN
NAME
NO.
CLAMP
7
I/O
DESCRIPTION
O
Miller clamp output
DESAT
2
I
Desaturation voltage input
FLT
13
O
Fault output, low-active during DESAT condition
GND1
9, 16
—
Input ground
GND2
3
—
Gate drive common. Connect to IGBT emitter
IN+
10
I
Non-inverting gate drive voltage control input
IN–
11
I
Inverting gate drive voltage control input
NC
4
—
Not connected
OUT
6
O
Gate drive voltage output
RDY
12
O
Power-good output, active high when both supplies are good
RST
14
I
Reset input, apply a low pulse to reset fault latch
VCC1
15
—
Positive input supply (3 V to 5.5 V)
VCC2
5
—
Most positive output supply potential
VEE2
1, 8
—
Output negative supply. Connect to GND2 for unipolar-supply application
4
Submit Documentation Feedback
Copyright © 2015–2017, Texas Instruments Incorporated
Product Folder Links: ISO5451
ISO5451
www.ti.com
SLLSEO1C – JUNE 2015 – REVISED JANUARY 2017
7 Specifications
7.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted) (1)
MIN
MAX
UNIT
GND1 – 0.3
6
V
(VCC2 – GND2)
–0.3
35
V
Negative supply voltage output
side
(VEE2 – GND2)
–17.5
0.3
V
V(SUP2)
Total supply output voltage
(VCC2 – VEE2)
–0.3
35
V
VOUT
Gate driver output voltage
VEE2 – 0.3
VCC2 + 0.3
V
2.7
A
5.5
A
VCC1
Supply voltage input side
VCC2
Positive supply voltage output
side
VEE2
I(OUTH)
Gate driver high output current
Gate driver high output current
(max pulse width = 10 μs, max duty cycle = 0.2%)
I(OUTL)
Gate driver low output current
Gate driver high output current
(max pulse width = 10 μs, max duty cycle = 0.2%)
V(LIP)
Voltage at IN+, IN–, FLT, RDY, RST
I(LOP)
Output current of FLT, RDY
V(DESAT)
Voltage at DESAT
V(CLAMP)
Clamp voltage
TJ
TSTG
(1)
GND1 –0.3
VCC1 + 0.3
V
10
mA
GND2 – 0.3
VCC2 + 0.3
V
VEE2 – 0.3
VCC2 + 0.3
V
Junction temperature
–40
150
°C
Storage temperature
–65
150
°C
Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only and functional operation of the device at these or any conditions beyond those indicated under recommended operating conditions
is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability
7.2 ESD Ratings
VALUE
V(ESD)
(1)
(2)
Electrostatic discharge
Human body model (HBM), per ANSI/ESDA/JEDEC JS-001 (1)
±4000
Charged-device model (CDM), per JEDEC specification JESD22C101 (2)
±1500
UNIT
V
JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.
7.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
MIN
VCC1
Supply voltage input side
VCC2
NOM
MAX
UNIT
3
5.5
V
Positive supply voltage output side (VCC2 – GND2)
15
30
V
VEE2
Negative supply voltage output side (VEE2 – GND2)
–15
0
V
V(SUP2)
Total supply voltage output side (VCC2 – VEE2)
15
30
V
VIH
High-level input voltage (IN+, IN–, RST)
0.7 × VCC1
VCC1
V
VIL
Low-level input voltage (IN+, IN–, RST)
0
0.3 × VCC1
V
tUI
Pulse width at IN+, IN– for full output (CLOAD = 1 nF)
tRST
Pulse width at RST for resetting fault latch
800
TA
Ambient temperature
–40
40
ns
ns
25
125
Submit Documentation Feedback
Copyright © 2015–2017, Texas Instruments Incorporated
Product Folder Links: ISO5451
°C
5
ISO5451
SLLSEO1C – JUNE 2015 – REVISED JANUARY 2017
www.ti.com
7.4 Thermal Information
ISO5451
THERMAL METRIC (1)
DW (SOIC)
UNIT
16 PINS
RθJA
Junction-to-ambient thermal resistance
99.6
°C/W
RθJC(top)
Junction-to-case (top) thermal resistance
48.5
°C/W
RθJB
Junction-to-board thermal resistance
56.5
°C/W
ψJT
Junction-to-top characterization parameter
29.2
°C/W
ψJB
Junction-to-board characterization parameter
56.5
°C/W
(1)
For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application
report.
7.5 Power Ratings
PARAMETER
PD
Maximum power dissipation (1)
PID
Maximum input power dissipation
POD
Maximum output power dissipation
(1)
6
TEST CONDITIONS
MIN
TYP
MAX
UNIT
1255
mW
175
mW
1080
mW
Full chip power dissipation is de-rated 10.04 mW/°C beyond 25°C ambient temperature. At 125°C ambient temperature, a maximum of
251 mW total power dissipation is allowed. Power dissipation can be optimized depending on ambient temperature and board design,
while ensuring that Junction temperature does not exceed 150°C.
Submit Documentation Feedback
Copyright © 2015–2017, Texas Instruments Incorporated
Product Folder Links: ISO5451
ISO5451
www.ti.com
SLLSEO1C – JUNE 2015 – REVISED JANUARY 2017
7.6 Insulation Characteristics
SPECIFICATION
UNIT
CLR
External clearance (1)
PARAMETER
Shortest terminal-to-terminal distance through air
TEST CONDITIONS
>8
mm
CPG
External creepage
(1)
Shortest terminal-to-terminal distance across the
package surface
>8
mm
DTI
Distance through the insulation
Minimum internal gap (internal clearance)
>21
μm
CTI
Tracking resistance (comparative tracking
index)
DIN EN 60112 (VDE 0303-11); IEC 60112;
UL 746A
>600
V
Material Group
According to IEC 60664-1
Overvoltage category (according to IEC
60664-1)
DIN V VDE V 0884-10 (VDE V 0884-10):2006-12
VIORM
I-IV
Rated Mains Voltage ≤ 600 VRMS
I-III
Rated Mains Voltage ≤ 1000 VRMS
I-II
(2)
Maximum repetitive peak isolation voltage
VIOWM Maximum isolation working voltage
I
Rated Mains Voltage ≤ 300 VRMS
AC voltage (bipolar)
1420
VPK
AC voltage. Time dependent dielectric breakdown
(TDDB) Test, see Figure 1
1000
VRMS
DC voltage
1420
VDC
8000
6250
VIOTM
Maximum Transient isolation voltage
VTEST = VIOTM, t = 60 sec (qualification), t = 1 sec
(100% production)
VIOSM
Maximum surge isolation voltage (3)
Test method per IEC 60065, 1.2/50 μs waveform,
VTEST = 1.6 × VIOSM = 10000 VPK (qualification) (3)
Apparent charge (4)
qpd
RIO
Isolation resistance, input to output
CIO
Barrier capacitance, input to output
(5)
(5)
VPK
Method a: After I/O safety test subgroup 2/3,
Vini = VIOTM, tini = 60 s;
Vpd(m) = 1.2 × VIORM = 1704 VPK ,
tm = 10 s
≤5
Method a: After environmental tests subgroup 1,
Vini = VIOTM, tini = 60 s;
Vpd(m) = 1.6 × VIORM = 2272 VPK ,
tm = 10 s
≤5
Method b1: At routine test (100% production) and
preconditioning (type test)
Vini = VIOTM, tini = 60 s;
Vpd(m) = 1.875 × VIORM = 2663 VPK ,
tm = 10 s
≤5
pC
VIO = 500 V, TA = 25°C
> 1012
Ω
VIO = 500 V, 100°C ≤ TA ≤ 125°C
> 1011
Ω
VIO = 500 V at TS = 150°C
> 109
Ω
~1
pF
VIO = 0.4 × sin (2πft), f = 1 MHz
Pollution degree
2
Climatic category
40/125/21
UL 1577
VISO
(1)
(2)
(3)
(4)
(5)
Withstanding Isolation voltage
VTEST = VISO, t = 60 sec (qualification),
VTEST = 1.2 × VISO = 6840 VRMS,
t = 1 sec (100% production)
5700
VRMS
Creepage and clearance requirements should be applied according to the specific equipment isolation standards of an application. Care
should be taken to maintain the creepage and clearance distance of a board design to ensure that the mounting pads of the isolator on
the printed-circuit board do not reduce this distance. Creepage and clearance on a printed-circuit board become equal in certain cases.
Techniques such as inserting grooves and/or ribs on a printed circuit board are used to help increase these specifications.
This coupler is suitable for basic electrical insulation only within the maximum operating ratings. Compliance with the safety ratings shall
be ensured by means of suitable protective circuits.
Testing is carried out in air or oil to determine the intrinsic surge immunity of the isolation barrier.
Apparent charge is electrical discharge caused by a partial discharge (pd).
All pins on each side of the barrier tied together creating a two-terminal device
Submit Documentation Feedback
Copyright © 2015–2017, Texas Instruments Incorporated
Product Folder Links: ISO5451
7
ISO5451
SLLSEO1C – JUNE 2015 – REVISED JANUARY 2017
www.ti.com
7.7 Safety-Related Certifications
VDE
CSA
UL
CQC
TUV
Certified according to
EN 61010-1:2010 (3rd Ed)
and
EN 609501:2006/A11:2009/A1:2010
/
A12:2011/A2:2013
Certified according to DIN
V VDE V 0884-10
(VDE V 0884-10):2006-12
and DIN EN 60950-1
(VDE 0805 Teil 1):201101
Certified according to CSA
Certified according to UL
Component Acceptance
1577 Component
Notice 5A, IEC 60950-1
Recognition Program
and IEC 60601-1
Certified according to GB
4943.1-2011
Reinforced Insulation
Maximum Transient
isolation voltage, 8000
VPK;
Maximum surge isolation
voltage, 6250 VPK,
Maximum repetitive peak
isolation voltage, 1420
VPK
Isolation Rating of 5700
VRMS;
Reinforced insulation per
CSA 60950- 1- 07+A1+A2
and IEC 60950-1 (2nd
Ed.), 800 VRMS max
working voltage (pollution
Single Protection, 5700
degree 2, material group
VRMS
I);
2 MOPP (Means of
Patient Protection) per
CSA 60601-1:14 and IEC
60601-1 Ed. 3.1, 250
VRMS (354 VPK) max
working voltage
5700 VRMS Reinforced
insulation per
EN 61010-1:2010 (3rd Ed)
up to working voltage of
600 VRMS
Reinforced Insulation,
5700 VRMS Reinforced
Altitude ≤ 5000m, Tropical
insulation per
climate, 400 VRMS
EN 60950maximum working voltage
1:2006/A11:2009/A1:2010
/
A12:2011/A2:2013 up to
working voltage of 800
VRMS
Certification completed
Certificate number:
40040142
Certification completed
Master contract
number:220991
Certification completed
Certificate number:
CQC16001141761
Certification completed
File number: E181974
Certification completed
Client ID number: 77311
7.8 Safety Limiting Values
Safety limiting intends to minimize potential damage to the isolation barrier upon failure of input or output circuitry. A failure of
the I/O can allow low resistance to ground or the supply and, without current limiting, dissipate sufficient power to overheat
the die and damage the isolation barrier, potentially leading to secondary system failures.
PARAMETER
IS
Safety input, output or supply current
PS
Safety input, output, or total power
TS
Maximum ambient safety
temperature
(1)
TEST CONDITIONS
MIN
TYP
MAX
RθJA = 99.6°C/W, VI = 3.6 V, TJ = 150°C,
TA = 25°C
349
RθJA = 99.6°C/W, VI = 5.5 V, TJ = 150°C,
TA = 25°C
228
RθJA = 99.6°C/W, VI = 15 V, TJ = 150°C,
TA = 25°C
84
RθJA = 99.6°C/W, VI = 30 V, TJ = 150°C,
TA = 25°C
42
RθJA = 99.6°C/W, TJ = 150°C, TA = 25°C
1255 (1)
UNIT
mA
150
mW
°C
Input, output, or the sum of input and output power should not exceed this value
The safety-limiting constraint is the maximum junction temperature specified in the data sheet. The power
dissipation and junction-to-air thermal impedance of the device installed in the application hardware determines
the junction temperature. The assumed junction-to-air thermal resistance in the Thermal Information table is that
of a device installed on a high-K test board for leaded surface-mount packages. The power is the recommended
maximum input voltage times the current. The junction temperature is then the ambient temperature plus the
power times the junction-to-air thermal resistance.
8
Submit Documentation Feedback
Copyright © 2015–2017, Texas Instruments Incorporated
Product Folder Links: ISO5451
ISO5451
www.ti.com
SLLSEO1C – JUNE 2015 – REVISED JANUARY 2017
7.9 Electrical Characteristics
Over recommended operating conditions unless otherwise noted. All typical values are at TA = 25°C, VCC1 = 5 V, VCC2 –
GND2 = 15 V, GND2 – VEE2 = 8 V
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
2.25
V
VOLTAGE SUPPLY
VIT+(UVLO1)
Positive-going UVLO1 threshold voltage
input side (VCC1 – GND1)
VIT-(UVLO1)
Negative-going UVLO1 threshold voltage
input side (VCC1 – GND1)
VHYS(UVLO1)
UVLO1 Hysteresis voltage (VIT+ – VIT–)
input side
VIT+(UVLO2)
Positive-going UVLO2 threshold voltage
output side (VCC2 – GND2)
VIT-(UVLO2)
Negative-going UVLO2 threshold voltage
output side (VCC2 – GND2)
VHYS(UVLO2)
UVLO2 Hysteresis voltage (VIT+ – VIT–)
output side
IQ1
Input supply quiescent current
2.8
4.5
mA
IQ2
Output supply quiescent current
3.6
6
mA
1.7
V
0.24
12
9.5
V
13
V
11
V
1
V
LOGIC I/O
VIT+(IN,RST)
Positive-going input threshold voltage (IN+,
IN–, RST)
VIT-(IN,RST)
Negative-going input threshold voltage
(IN+, IN–, RST)
VHYS(IN,RST)
Input hysteresis voltage (IN+, IN–, RST)
IIH
High-level input leakage at (IN+)
IIL
Low-level input leakage at (IN–, RST)
IPU
Pull-up current of FLT, RDY
V(RDY) = GND1, V(FLT) = GND1
VOL
Low-level output voltage at FLT, RDY
I(FLT) = 5 mA
(1)
0.7 × VCC1
0.3 × VCC1
IN+ = VCC1
(2)
IN– = GND1, RST = GND1
V
V
0.15 × VCC1
V
100
µA
–100
µA
100
µA
0.2
V
2
V
GATE DRIVER STAGE
V(OUTPD)
Active output pulldown voltage
IOUT = 200 mA, VCC2 = open
V(OUTH)
High-level output voltage
IOUT = –20 mA
V(OUTL)
Low-level output voltage
IOUT = 20 mA
I(OUTH)
High-level output peak current
IN+ = high, IN– = low,
VOUT = VCC2 - 15 V
1.5
2.5
A
I(OUTL)
Low-level output peak current
IN+ = low, IN– = high,
VOUT = VEE2 + 15 V
3.4
5
A
VCC2 – 0.5
VCC2 – 0.24
VEE2 + 13
V
VEE2 + 50
mV
ACTIVE MILLER CLAMP
V(CLP)
Low-level clamp voltage
I(CLP) = 20 mA
I(CLP)
Low-level clamp current
V(CLAMP) = VEE2 + 2.5 V
V(CLTH)
Clamp threshold voltage
VEE2 + 0.015
VEE2 + 0.08
V
1.6
2.5
1.6
2.1
2.5
A
V
1.3
V
SHORT CIRCUIT CLAMPING
V(CLP_OUT)
Clamping voltage
(VOUT - VCC2)
IN+ = high, IN– = low, tCLP=10 µs,
I(OUTH) = 500 mA
0.8
V(CLP_CLAMP)
Clamping voltage
(VCLP - VCC2)
IN+ = high, IN– = low, tCLP=10 µs,
I(CLP) = 500 mA
1.3
V(CLP_CLAMP)
Clamping voltage at CLAMP
IN+ = High, IN– = Low, I(CLP) = 20
mA
0.7
1.1
V
0.58
mA
V
DESAT PROTECTION
I(CHG)
Blanking capacitor charge current
V(DESAT) - GND2 = 2 V
0.42
0.5
I(DCHG)
Blanking capacitor discharge current
V(DESAT) - GND2 = 6 V
9
14
V(DSTH)
DESAT threshold voltage with respect to
GND2
8.3
9
V(DSL)
DESAT voltage with respect to GND2,
when OUT is driven low
0.4
(1)
(2)
mA
9.5
V
1
V
IIH for IN–, RST pin is zero as they are pulled high internally.
IIL for IN+ is zero, as it is pulled low internally.
Submit Documentation Feedback
Copyright © 2015–2017, Texas Instruments Incorporated
Product Folder Links: ISO5451
9
ISO5451
SLLSEO1C – JUNE 2015 – REVISED JANUARY 2017
www.ti.com
7.10 Switching Characteristics
Over recommended operating conditions unless otherwise noted. All typical values are at TA = 25°C, VCC1 = 5 V, VCC2 –
GND2 = 15 V, GND2 – VEE2 = 8 V
MIN
TYP
MAX
tr
Output signal rise time
PARAMETER
12
20
35
ns
tf
Output signal fall time
12
20
37
ns
tPLH, tPHL
Propagation Delay
76
110
ns
tsk-p
Pulse Skew |tPHL – tPLH|
20
ns
tsk-pp
Part-to-part skew
30 (1)
ns
tGF
TEST CONDITIONS
CLOAD = 1 nF, see Figure 38, Figure 39 and
Figure 40
Glitch filter on IN+, IN–, RST
tDESAT
(10%)
DESAT sense to 10% OUT delay
tDESAT
(GF)
DESAT glitch filter delay
tDESAT
(FLT)
DESAT sense to FLT-low delay
see Figure 40
Leading edge blanking time
see Figure 38 and Figure 39
tGF(RSTFLT)
Glitch filter on RST for resetting FLT
CI
Input capacitance (2)
VI = VCC1/2 + 0.4 × sin (2πft), f = 1 MHz,
VCC1 = 5 V
CMTI
Common-mode transient immunity
VCM = 1500 V, see Figure 41
(1)
(2)
10
20
30
40
ns
300
415
500
ns
330
tLEB
UNIT
330
2000
2420
ns
400
500
ns
800
ns
300
2
50
ns
100
pF
kV/μs
Measured at same supply voltage and temperature condition
Measured from input pin to ground.
Submit Documentation Feedback
Copyright © 2015–2017, Texas Instruments Incorporated
Product Folder Links: ISO5451
ISO5451
www.ti.com
SLLSEO1C – JUNE 2015 – REVISED JANUARY 2017
7.11 Insulation Characteristics Curves
Safety Margin Zone: 1200 VRMS,1268 Years
Operating Zone: 1000 VRMS, 676 Years
TDDB Line (