0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SN65HVD255DEVM

SN65HVD255DEVM

  • 厂商:

    BURR-BROWN(德州仪器)

  • 封装:

    -

  • 描述:

    SN65HVD255 - Interface, CAN Evaluation Board

  • 数据手册
  • 价格&库存
SN65HVD255DEVM 数据手册
User's Guide SLLU158 – December 2011 CAN EVM User Guide This User Guide details the CAN EVM (Controller Area Network Evaluation Module) transceiver operation. It comes with the SN65HVD255 CAN transceiver factory installed. The CAN EVM may be user-reconfigured for use with the all TI CAN transceiver families: SN65HVD23x, SN65HVD25x, SN65HVD10x0 and SN65HVDA54x by replacing the transceiver and setting jumpers on the EVM as outlined in this document. This User Guide explains the EVM configurations for basic CAN evaluation, various load and termination settings. Topic 1 2 3 ........................................................................................................................... Page Introduction ........................................................................................................ 2 2 EVM Setup and Operation ................................................................................. 5 CAN EVM Configuration for SN65HVD255 (Factory Installed) ................................... 9 SLLU158 – December 2011 Submit Documentation Feedback CAN EVM User Guide Copyright © 2011, Texas Instruments Incorporated 1 Introduction 1 Introduction 1.1 Overview www.ti.com Texas Instruments offers a broad portfolio of High Speed (HS) CAN transceivers compatible with the ISO11898-2 High Speed CAN standards. These include 5V VCC only, 3.3V VCC only, 5V VCC with I/O level shifting and galvanic-isolated CAN transceivers. These CAN transceiver families include product mixes with varying features such as low power standby modes with and without wake up, silent modes, loop back and diagnostic modes. The Texas Instruments CAN EVM helps designers evaluate the operation and performance of various TI CAN transceivers. It also provides PCB footprints for different bus termination, bus filtering and protection concepts. The CAN EVM is provided with the SN65HVD255 installed. It is easily configured by the customer for the SN65HVD23x, SN65HVD25x, SN65HVD10x0 and SN65HVDA54x CAN transceiver families as needed by jumper settings, simple soldering tasks and replacement of standard components. A separate EVM is available for the galvanic-isolated CAN transceiver family. 1.2 CAN EVM The CAN EVM has simple connections to all necessary pins of the CAN transceiver device, and jumpers where necessary to provide flexibility for device pin and CAN bus configuration. There are test points (loops) for all main points where probing is necessary for evaluation such as GND, VCC, TXD, RXD, CANH, CANL, Pin 8 (mode pin), Pin 5 (various functions). The EVM supports many options for CAN bus configuration. It is pre-configured with two 120Ω resistors that may be connected on the bus via jumpers: a single resistor is used with the EVM as a terminated line end (CAN is defined for 120Ω impedance twisted pair cable) or both resistors in parallel for electrical measurements representing the 60Ω load the transceiver “sees” in a properly terminated network (i.e. 120Ω termination resistors at both ends of the cable). If the application requires “split” termination, TVS diodes for protection, or Common Mode (CM) Choke, the EVM has footprints available for this via customer installation of the desired component(s). Figure 1. EVM PC Board 2 CAN EVM User Guide Copyright © 2011, Texas Instruments Incorporated SLLU158 – December 2011 Submit Documentation Feedback TB1 2 1 2PIN_TERMINAL_BLOCK Header 10x1 1 JMP2 VRXD D3 LED R20 330 C8 4.7uF R6 DNI C10 10uF VCC VCC Place near DUT Pint C5 DNI R5 DNI C11 1uF R10 0 C12 .1uF C3 DNI VCC TP1 Test Point TP7 Test Point TP9 Test Point R13 0 TP10 Test Point 1 Copyright © 2011, Texas Instruments Incorporated 1 VCC VCC 1 1 VCC 4 3 2 1 C1 DNI STB SPL RXD TP8 Test Point 0 R19 0 R17 0 5 6 7 8 R4 SN65HVD1040 CANL Vcc GND CANH TXD U1 1 1 L1 2 1 4 R9 5 1 3 R18 4.7k 4 JMP6 VCC C6 DNI 0 VRXD 2 3 Header T 4pin 4 R14 0 TP3 Test Point R2 DNI 1 JMP1 R1 4.7k C9 1uF VCM R3 0 1 2 JMP4 R11 120 1 1 2 JMP5 TP12 Test Point 1 R12 120 R15 DNI R7 DNI R8 330 C7 DNI TP6 Test Point R16 330 C4 TP4 DNI Test Point C2 DNI Verify EIA 0603 size versus 0603 TP13 Test Point 1 TP11 Test Point 1 1 SLLU158 – December 2011 Submit Documentation Feedback 1 2 2 1 MMBZ D2 MMBZ D1 3 3 1 TP2 Test Point 1 VCC Test Point TP5 1 2 3 4 Header 4x1 JMP3 www.ti.com Introduction Figure 2. EVM Schematic CAN EVM User Guide 3 Introduction www.ti.com Table 1. Connection Type Description JMP1 4 pin jumper JMP2 10 pin header Connection for access to all critical digital I/O, supply and GND for driving the CAN transceiver externally with test equipment or interfaced to a processor EVM JMP3 4 pin header CAN bus connection (CANH, CANL) and GND JMP4 2 pin jumper Connect 120Ω CAN termination to the bus. Used separately for a single termination if EVM is at end of the CAN bus and termination isn’t in the cable. Used in combination with JMP5 to get to second CAN termination to represent the combined 60Ω load for CAN transceiver parametric measurement. JMP5 2 pin jumper Connect 120Ω CAN termination to the bus. Used in combination with JMP4 to get to second CAN termination to represent the combined 60Ω load for CAN transceiver parametric measurement. JMP6 5 pin jumper Functional use of pin 5. Options for use are:A) 4.7kΩ pull up to VCC for transceiver with digital input on pin 5B) 0Ω pull down to GND for transceiver with digital input on pin 5C) Active split termination: for CAN transceiver with VREF or SPLIT pin where active split termination is desired. Connect to VCM and populate the components R7/R15 and C4 as required for the system.D) VRXD (VIO) for CAN transceivers with a separate VRXD (VIO) for I/O level shifting. TB1 2 pin jumper VCC supply and GND connection for the EVM Used for mode selection on pin 8 (4.7kΩ pull up to VCC, 0Ω pull down to GND, customer installable pull down for devices with slew rate control RS pin). TP1 TXD, Device Pin 1 test point TP2 CANH (bus) test point TP3 Device Pin 8 test point TP4 CANH via 330Ω serial resistor test point TP5 CANL (bus) test point TP6 CANL via 330Ω serial resistor test point TP7 Test Point RXD, Device Pin 4 test point TP8 Device Pin 5 test point TP9 VCC test point TP10 TP11 TP12 GND test point TP13 4 CAN EVM User Guide Copyright © 2011, Texas Instruments Incorporated SLLU158 – December 2011 Submit Documentation Feedback 2 EVM Setup and Operation www.ti.com 2 2 EVM Setup and Operation This section describes the setup and operation of the EVM for parameter performance evaluation. 2.1 2.1.1 Overview & Basic Operation Settings VCC Power Supply (TB1 or TP9 or JMP2) The basic setup of the CAN EVM uses a single power supply required to evaluate standard 5V or 3.3V single supply transceiver devices performance. For single-supply transceivers, connect the 5V or 3.3V VCC supply to the TB1 jumper header, or the VCC and GND test-point loops. The power supplied should meet the required specification of VCC for the transceiver being tested. LED D3 is used to indicate VCC presence. 2.1.2 I/O Power Supply VRXD or VIO (JMP2, JMP6 or TP8) For devices with I/O level shifting, a second supply pin for the I/O or RXD pin is on Pin 5 of the transceiver device. A second power supply is needed to test one of these devices and should be connected via JMP2, JMP6 or TP8. A local buffering and decoupling capacitor should be installed at C6 if the EVM is used for one of these devices. 2.1.3 Main Supply and I/O Header (JMP2) All key I/O and supply GND functions are brought to this header. It may be used on either interface to test equipment or a short cable could be made to connect to either an existing customer application board or MCU/DSP EVM board for a processor with a CAN controller Table 2. Pin Connection Description 1 MODE 2 TXD Pin 1 of Transceiver. TXD (Transmit Data) 3 GND Pin 2 of Transceiver. GND. 4 GND Pin 2 of Transceiver. GND. 5 RXD Pin 4 of Transceiver. RXD (Receive Data) 6 GND Pin 2 of Transceiver. GND. 7 VCC 8 GND 9 P5 10 VRXD Pin 8 of Transceiver, normally used for Mode control. Examples: RS, S, STB. Pin 3 of Transceiver. VCC Pin 2 of Transceiver. GND. Pin 5 of Transceiver, various functions depending on transceiver. Examples: VREF, SPLIT, VRXD, VIO, LBK, EN, AB and No Connect (NC). Connects to Jumper JMP6 VRXD header to allow flexibility in using device with power supply for I/O on Pin 5 of transceiver. This header is arranged to provide a separate grounds for each signal pair (TXD/GND and RXD/GND). If the EVM is being used with lab equipment, separate cables can be connected to these main points via simple 2 pin header connectors.If the board is being connected to a processor based system, a single cable with all power & signals can be connected via a 10 pin header cable to this port. 2.1.4 TXD Input (JMP2 or TP1) The TXD (pin 1) of the transceiver, transmit data is routed to JMP2 and TP1. The signal path to the JMP2 header is pre-installed with a 0Ω series resistor, R10. 2.1.5 RXD Output (JMP2 or TP7) The RXD (pin 4) of the transceiver, receive data is routed to JMP2 and TP7. The signal path to the JMP2 header is pre-installed with a 0Ω series resistor, R13. SLLU158 – December 2011 Submit Documentation Feedback CAN EVM User Guide Copyright © 2011, Texas Instruments Incorporated 5 2 EVM Setup and Operation 2.1.6 www.ti.com MODE Select/ Pin 8 (JMP1, JMP2 or TP3) Pin 8 of the transceiver is normally a mode control pin of the device. Pin 8 of the device is routed to JMP1, JMP2 and TP7. 2.1.7 MODE - JMP1 configurations (3 way jumper) If using separate I/O inputs JMP1 will be used to configure pin 8 to a pull up to VCC or pull down to GND configuration. For most devices when Pin 8 is pulled to GND the device will be in “normal” or high speed mode. R3 is pre-installed with 0Ω resistor to GND for this purpose. For most devices when Pin 8 is pulled to VCC the device will be in a silent or low power standby mode. Devices with slope control mode use the resistance to ground value to determine the slope of the driver output. R2 is left open for customers who want to install a resistance to ground and use slope mode. 2.1.8 JMP2 configuration Using header JMP2 which assumes all the digital I/O signals, VCC, GND are routed to an external system. Ensure that the MODE (JMP1) jumper settings are not conflicting with signals to JMP2. 2.1.9 TP3 configuration This connects directly to device pin 8. Ensure JMP1 configuration isn’t conflicting if TP3 is used as the input connection. 2.1.10 Pin 5 (JMP6, JMP2 or TP8) Pin 5 of the transceiver have various uses depending on the transceiver. Examples are VREF, SPLIT, VRXD, VIO, LBK, EN, AB and No Connect (NC). Pin 5 of the device is routed to JMP6, JMP2 and TP8. 2.1.11 Pin 5 – JMP6 configurations (4 way jumper) If using separate I/O inputs JMP6 will be used to configure pin 5 to: pull up to VCC, pull down to GND, VRXD / VIO supply input or VREF/SPLIT termination output. • VREF/SPLIT termination: If the device & application support split termination then JMP6 should be set to VCM (V Common Mode) to drive the VREF/SPLIT pin common mode stabilizing voltage output to the center tap of the split termination capacitor. These components will need to be installed on the EVM as outlined in the CAN bus termination section. • No Connection: If the device & application require no use of pin 5 then it may be left open. If the device has VREF or SPLIT pin but the application isn’t using the pin for split termination then a capacitor may be added on C6 to improve EMC performance. • 2nd Mode / Control Input: if the device & application use pin 5 as a second mode or control pin then JMP6 should be set to as either a pull up to VCC or pull down to GND as necessary. • I/O & RXD level shifting supply: if the device & application use with VIO or VRXD to level shift I/O pins on the transceiver then JMP6 may be set to VRXD which connects pin 5 of the device to VRXD pin on JMP2. Local buffering and bypass capacitor C6 should be installed. 2.1.12 JMP2 configuration Using header JMP2 assumes all the digital I/O signals, VCC, GND are routed to an external system. Ensure that Pin 5 (JMP6) jumper settings are not conflicting with signals to JMP2. For power supply VRXD the jumper needs to be set to route JMP2 supply input to the transceiver pin. 2.1.13 TP8 configuration This connects directly to device pin 5. Ensure JMP6 configuration isn’t conflicting if TP8 is used as an input connection. 6 CAN EVM User Guide Copyright © 2011, Texas Instruments Incorporated SLLU158 – December 2011 Submit Documentation Feedback 2 EVM Setup and Operation www.ti.com 2.2 Using CAN Bus Load, Termination and Protection Configurations The CAN EVM is populated with two 120Ω power resistors selectable via jumpers between CANH and CANL. By using one, the EVM may be used as a terminated end of a bus. For electrical measurements to represent the total loading of the bus, use both 120Ω resistors in parallel to give the standard 60Ω load for parametric measurement. The EVM also has footprints is split termination is needed for the application. The table below summarizes how to use these termination options. If split termination is used, care must be taken to match the resistors. The common mode filter frequency may be calculated by: fC = 1/(2πRC). Normally, the split capacitance is in the range of 4.7nF to 100nF. Keep in mind this is the common mode filter frequency, not a differential filter that will impact the differential CAN signal directly. Table 3. Bus Termination Configuration Termination Configuration Split Termination Footprints 120Ω Resistors JMP4 JMP5 Standard Termination (120Ω) shorted open 60Ω load - Electrical Parameterics shorted shorted Split Termination (Common Mode Stabilization) open open Split Termination Footprints R7 R15 C4 N/A N/A N/A 60Ω 60Ω populated The EVM also has footprints for various protection schemes to enhance robustness for extreme system level EMC requirements. The table below summarizes these options. Table 4. Protection and Filtering Configuration Configuration Series Resistors or Common Mode Choke Bus Filtering Caps Transient Protection Footprint Reference R9 / R14 or L1 (common footprint) C2 / C7 C2 / C7 or D1 / D2 SLLU158 – December 2011 Submit Documentation Feedback Use Case Population & Description Direct CAN transceiver to bus connection R9 and R14 populated with 0Ω (default population) Series resistance protection CAN transceiver to bus connection R9 and R14 populated with MELF resistor as necessary for harsh EMC environment CM choke (bus filter) L1 populated with CM choke to filter noise as necessary for harsh EMC environment Bus filter Filter noise as necessary for harsh EMC environment. Filter caps may be used in combination with L1 CM choke. Transient & ESD Protection To add extra protection for system level transients and ESD protection TVS diode population option via D1/D2 footprint or varistor population via C2 / C7 footprint. CAN EVM User Guide Copyright © 2011, Texas Instruments Incorporated 7 2 EVM Setup and Operation 2.3 www.ti.com Using Customer Installable I/O options for Current Limiting, Pullup/Pulldown, Noise Filtering The CAN EVM has footprints on the PCB for the installation of various filtering and protection options to adapt the EVM to match CAN network topology requirements if the EVM is being used as a CAN node. Each digital input or output pin has footprints to allow for series current limiting resistors (default populated with 0Ω), pull up or down resistors depending on pin use and a capacitor to GND which configured with the serial resistor allows for RC filters (noisy environments). The table below lists these features for each of the digital input and output pins of the EVM. Replace or populate the RC components as necessary for the application. Table 5. RC Filter / Protection Lists Device Pin No. Description Jumperable Type Pull Up Pull Down Series R Pull Up/Down C to GND 1 TXD Input N/A N/A R10 R6 PU C3 2 RXD Output N/A N/A R13 R5 PU C5 NC No Connect N/A N/A N/A N/A N/A VREF/SPLIT Output N/A N/A R17 N/A C4 / C6 Split termination: JMP6 to route output to split termination center point capacitor C4. EMC for systems not using split termination: C6 to GND. VRXD/VIO Supply Input N/A N/A R17 N/A C9 / C6 Use TM6, JMP6 & JMP2 as necessary to provide supply input. AB / EN / LBK Input R18 (JMP6) R19 (JMP6) R17 N/A C6 S, RS, STB Input R1 (JMP1) R2 / R3 (JMP1) R4 N/A C1 NC No Connect N/A N/A N/A N/A N/A 5 8 8 Description CAN EVM User Guide Copyright © 2011, Texas Instruments Incorporated R2 pull down to GND (JMP1) user installable for use with slope mode on devices with RS pin. SLLU158 – December 2011 Submit Documentation Feedback CAN EVM Configuration for SN65HVD255 (Factory Installed) www.ti.com 3 CAN EVM Configuration for SN65HVD255 (Factory Installed) The SN65HVD255 meets ISO1189-2 High Speed CAN (Controller Area Network) Physical Layer standard (transceiver). It is designed as a next generation CAN for the ‘251 & ‘1050 pinout. It has very fast loop times with a wide range of bus loading allowing for data rates up to 1 megabit per second (Mbps) in long and highly loaded networks and higher data rates in small networks. The device includes many protection features providing device and CAN network robustness. The device has two modes: normal mode and silent mode selected on pin 8. TXD S GND CANH VCC CANL RXD NC Figure 3. SN65HVD255 Basic Block Diagram & Pin Out Table 6. EVM Connection Settings for SN65HVD255 Connection Description JMP1 Mode selection: Pull up to VCC for Silent Mode, Pull down to GND for normal mode JMP2 Connection for access to all critical digital I/O, supply and GND if being externally driven by test equipment or interfaced to a processor EVM. Note: ensure that JMP1, JMP6 & TB1 settings don't conflict with JMP2 if it is used. JMP3 CAN bus connection (CANH, CANL) and GND as necessary if interfacing EVM to a CAN network JMP4 Connect if necessary for a single CAN network termination JMP5 Connect if necessary for in parallel with JMP4 to get a 60Ω load to measure CAN parametrics JMP6 N/A: SN65HVD255 is no connect on pin 5 of the transceiver SLLU158 – December 2011 Submit Documentation Feedback CAN EVM User Guide Copyright © 2011, Texas Instruments Incorporated 9 Evaluation Board/Kit Important Notice Texas Instruments (TI) provides the enclosed product(s) under the following conditions: This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end-product fit for general consumer use. Persons handling the product(s) must have electronics training and observe good engineering practice standards. As such, the goods being provided are not intended to be complete in terms of required design-, marketing-, and/or manufacturing-related protective considerations, including product safety and environmental measures typically found in end products that incorporate such semiconductor components or circuit boards. This evaluation board/kit does not fall within the scope of the European Union directives regarding electromagnetic compatibility, restricted substances (RoHS), recycling (WEEE), FCC, CE or UL, and therefore may not meet the technical requirements of these directives or other related directives. Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/kit may be returned within 30 days from the date of delivery for a full refund. THE FOREGOING WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY SELLER TO BUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all claims arising from the handling or use of the goods. Due to the open construction of the product, it is the user’s responsibility to take any and all appropriate precautions with regard to electrostatic discharge. EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTH ABOVE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. TI currently deals with a variety of customers for products, and therefore our arrangement with the user is not exclusive. TI assumes no liability for applications assistance, customer product design, software performance, or infringement of patents or services described herein. Please read the User’s Guide and, specifically, the Warnings and Restrictions notice in the User’s Guide prior to handling the product. This notice contains important safety information about temperatures and voltages. For additional information on TI’s environmental and/or safety programs, please contact the TI application engineer or visit www.ti.com/esh. No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, or combination in which such TI products or services might be or are used. FCC Warning This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end-product fit for general consumer use. It generates, uses, and can radiate radio frequency energy and has not been tested for compliance with the limits of computing devices pursuant to part 15 of FCC rules, which are designed to provide reasonable protection against radio frequency interference. Operation of this equipment in other environments may cause interference with radio communications, in which case the user at his own expense will be required to take whatever measures may be required to correct this interference. EVM Warnings and Restrictions It is important to operate this EVM within the input voltage range of (specified in SN65HVD25x data sheet) and the output voltage range of (specified in SN65HVD25x data sheet) . Exceeding the specified input range may cause unexpected operation and/or irreversible damage to the EVM. If there are questions concerning the input range, please contact a TI field representative prior to connecting the input power. Applying loads outside of the specified output range may result in unintended operation and/or possible permanent damage to the EVM. Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative. During normal operation, some circuit components may have case temperatures greater than 125° C. The EVM is designed to operate properly with certain components above 125° C as long as the input and output ranges are maintained. These components include but are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors. These types of devices can be identified using the EVM schematic located in the EVM User's Guide. When placing measurement probes near these devices during operation, please be aware that these devices may be very warm to the touch. Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2011, Texas Instruments Incorporated EVALUATION BOARD/KIT/MODULE (EVM) ADDITIONAL TERMS Texas Instruments (TI) provides the enclosed Evaluation Board/Kit/Module (EVM) under the following conditions: The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all claims arising from the handling or use of the goods. Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/kit may be returned within 30 days from the date of delivery for a full refund. THE FOREGOING LIMITED WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY SELLER TO BUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTH ABOVE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. Please read the User's Guide and, specifically, the Warnings and Restrictions notice in the User's Guide prior to handling the product. This notice contains important safety information about temperatures and voltages. For additional information on TI's environmental and/or safety programs, please visit www.ti.com/esh or contact TI. No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, or combination in which such TI products or services might be or are used. TI currently deals with a variety of customers for products, and therefore our arrangement with the user is not exclusive. TI assumes no liability for applications assistance, customer product design, software performance, or infringement of patents or services described herein. REGULATORY COMPLIANCE INFORMATION As noted in the EVM User’s Guide and/or EVM itself, this EVM and/or accompanying hardware may or may not be subject to the Federal Communications Commission (FCC) and Industry Canada (IC) rules. For EVMs not subject to the above rules, this evaluation board/kit/module is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end product fit for general consumer use. It generates, uses, and can radiate radio frequency energy and has not been tested for compliance with the limits of computing devices pursuant to part 15 of FCC or ICES-003 rules, which are designed to provide reasonable protection against radio frequency interference. Operation of the equipment may cause interference with radio communications, in which case the user at his own expense will be required to take whatever measures may be required to correct this interference. General Statement for EVMs including a radio User Power/Frequency Use Obligations: This radio is intended for development/professional use only in legally allocated frequency and power limits. Any use of radio frequencies and/or power availability of this EVM and its development application(s) must comply with local laws governing radio spectrum allocation and power limits for this evaluation module. It is the user’s sole responsibility to only operate this radio in legally acceptable frequency space and within legally mandated power limitations. Any exceptions to this are strictly prohibited and unauthorized by Texas Instruments unless user has obtained appropriate experimental/development licenses from local regulatory authorities, which is responsibility of user including its acceptable authorization. For EVMs annotated as FCC – FEDERAL COMMUNICATIONS COMMISSION Part 15 Compliant Caution This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC Interference Statement for Class A EVM devices This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC Interference Statement for Class B EVM devices This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. For EVMs annotated as IC – INDUSTRY CANADA Compliant This Class A or B digital apparatus complies with Canadian ICES-003. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Concerning EVMs including radio transmitters This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Concerning EVMs including detachable antennas Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. This radio transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Cet appareil numérique de la classe A ou B est conforme à la norme NMB-003 du Canada. Les changements ou les modifications pas expressément approuvés par la partie responsable de la conformité ont pu vider l’autorité de l'utilisateur pour actionner l'équipement. Concernant les EVMs avec appareils radio Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Concernant les EVMs avec antennes détachables Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. Le présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le manuel d’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur. SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER 【Important Notice for Users of this Product in Japan】 】 This development kit is NOT certified as Confirming to Technical Regulations of Radio Law of Japan If you use this product in Japan, you are required by Radio Law of Japan to follow the instructions below with respect to this product: 1. 2. 3. Use this product in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal Affairs and Communications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for Enforcement of Radio Law of Japan, Use this product only after you obtained the license of Test Radio Station as provided in Radio Law of Japan with respect to this product, or Use of this product only after you obtained the Technical Regulations Conformity Certification as provided in Radio Law of Japan with respect to this product. Also, please do not transfer this product, unless you give the same notice above to the transferee. Please note that if you could not follow the instructions above, you will be subject to penalties of Radio Law of Japan. Texas Instruments Japan Limited (address) 24-1, Nishi-Shinjuku 6 chome, Shinjuku-ku, Tokyo, Japan http://www.tij.co.jp 【ご使用にあたっての注】 本開発キットは技術基準適合証明を受けておりません。 本製品のご使用に際しては、電波法遵守のため、以下のいずれかの措置を取っていただく必要がありますのでご注意ください。 1. 2. 3. 電波法施行規則第6条第1項第1号に基づく平成18年3月28日総務省告示第173号で定められた電波暗室等の試験設備でご使用いただく。 実験局の免許を取得後ご使用いただく。 技術基準適合証明を取得後ご使用いただく。 なお、本製品は、上記の「ご使用にあたっての注意」を譲渡先、移転先に通知しない限り、譲渡、移転できないものとします。    上記を遵守頂けない場合は、電波法の罰則が適用される可能性があることをご留意ください。 日本テキサス・インスツルメンツ株式会社 東京都新宿区西新宿6丁目24番1号 西新宿三井ビル http://www.tij.co.jp SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER SPACER EVALUATION BOARD/KIT/MODULE (EVM) WARNINGS, RESTRICTIONS AND DISCLAIMERS For Feasibility Evaluation Only, in Laboratory/Development Environments. Unless otherwise indicated, this EVM is not a finished electrical equipment and not intended for consumer use. It is intended solely for use for preliminary feasibility evaluation in laboratory/development environments by technically qualified electronics experts who are familiar with the dangers and application risks associated with handling electrical mechanical components, systems and subsystems. It should not be used as all or part of a finished end product. Your Sole Responsibility and Risk. You acknowledge, represent and agree that: 1. 2. 3. 4. You have unique knowledge concerning Federal, State and local regulatory requirements (including but not limited to Food and Drug Administration regulations, if applicable) which relate to your products and which relate to your use (and/or that of your employees, affiliates, contractors or designees) of the EVM for evaluation, testing and other purposes. You have full and exclusive responsibility to assure the safety and compliance of your products with all such laws and other applicable regulatory requirements, and also to assure the safety of any activities to be conducted by you and/or your employees, affiliates, contractors or designees, using the EVM. Further, you are responsible to assure that any interfaces (electronic and/or mechanical) between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electrical shock hazard. You will employ reasonable safeguards to ensure that your use of the EVM will not result in any property damage, injury or death, even if the EVM should fail to perform as described or expected. You will take care of proper disposal and recycling of the EVM’s electronic components and packing materials. Certain Instructions. It is important to operate this EVM within TI’s recommended specifications and environmental considerations per the user guidelines. Exceeding the specified EVM ratings (including but not limited to input and output voltage, current, power, and environmental ranges) may cause property damage, personal injury or death. If there are questions concerning these ratings please contact a TI field representative prior to connecting interface electronics including input power and intended loads. Any loads applied outside of the specified output range may result in unintended and/or inaccurate operation and/or possible permanent damage to the EVM and/or interface electronics. Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative. During normal operation, some circuit components may have case temperatures greater than 60°C as long as the input and output are maintained at a normal ambient operating temperature. These components include but are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors which can be identified using the EVM schematic located in the EVM User's Guide. When placing measurement probes near these devices during normal operation, please be aware that these devices may be very warm to the touch. As with all electronic evaluation tools, only qualified personnel knowledgeable in electronic measurement and diagnostics normally found in development environments should use these EVMs. Agreement to Defend, Indemnify and Hold Harmless. You agree to defend, indemnify and hold TI, its licensors and their representatives harmless from and against any and all claims, damages, losses, expenses, costs and liabilities (collectively, "Claims") arising out of or in connection with any use of the EVM that is not in accordance with the terms of the agreement. This obligation shall apply whether Claims arise under law of tort or contract or any other legal theory, and even if the EVM fails to perform as described or expected. Safety-Critical or Life-Critical Applications. If you intend to evaluate the components for possible use in safety critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, such as devices which are classified as FDA Class III or similar classification, then you must specifically notify TI of such intent and enter into a separate Assurance and Indemnity Agreement. Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2012, Texas Instruments Incorporated IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily performed. TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use of any TI components in safety-critical applications. In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and requirements. Nonetheless, such components are subject to these terms. No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties have executed a special agreement specifically governing such use. Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI has specifically designated certain components which meet ISO/TS16949 requirements, mainly for automotive use. Components which have not been so designated are neither designed nor intended for automotive use; and TI will not be responsible for any failure of such components to meet such requirements. Products Applications Audio www.ti.com/audio Automotive and Transportation www.ti.com/automotive Amplifiers amplifier.ti.com Communications and Telecom www.ti.com/communications Data Converters dataconverter.ti.com Computers and Peripherals www.ti.com/computers DLP® Products www.dlp.com Consumer Electronics www.ti.com/consumer-apps DSP dsp.ti.com Energy and Lighting www.ti.com/energy Clocks and Timers www.ti.com/clocks Industrial www.ti.com/industrial Interface interface.ti.com Medical www.ti.com/medical Logic logic.ti.com Security www.ti.com/security Power Mgmt power.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video RFID www.ti-rfid.com OMAP Applications Processors www.ti.com/omap TI E2E Community e2e.ti.com Wireless Connectivity www.ti.com/wirelessconnectivity Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2012, Texas Instruments Incorporated
SN65HVD255DEVM 价格&库存

很抱歉,暂时无法提供与“SN65HVD255DEVM”相匹配的价格&库存,您可以联系我们找货

免费人工找货