SDAS137A − DECEMBER 1983 − REVISED DECEMBER 1994
•
•
•
•
SN54AS250A . . . JT PACKAGE
SN74AS250A . . . DW OR NT PACKAGE
(TOP VIEW)
4-Line to 1-Line Multiplexers That Can
Select 1-of-16 Data Inputs
Applications:
Boolean Function Generator
Parallel-to-Serial Converter
Data Source Selector
Buffered 3-State Bus Driver Inputs Permit
Multiplexing From n Lines to One Line
Package Options Include Plastic
Small-Outline (DW) Packages, Ceramic
Chip Carriers (FK), and Standard Plastic
(NT) and Ceramic (JT) 300-mil DIPs
E7
E6
E5
E4
E3
E2
E1
E0
OE
W
D
GND
description
The ′AS250A devices provide full binary decoding
to select 1-of-16 data inputs or use sources as an
input with an inverting W output. The selected
sources are buffered with symmetrical
propagation delay times. This reduces the
possibility of transients occurring at the output.
1
24
2
23
3
22
4
21
5
20
6
19
7
18
8
17
9
16
10
15
11
14
12
13
VCC
E8
E9
E10
E11
E12
E13
E14
E15
A
B
C
E5
E6
E7
NC
VCC
E8
E9
SN54AS250A . . . FK PACKAGE
(TOP VIEW)
A buffered output-enable (OE) input can be used
for n-line to 1-line cascading. Taking OE high
places the output in the high-impedance state. In
the high-impedance state, the output neither loads
nor drives the bus lines significantly.
OE does not affect the internal operations of the
data selector/multiplexer. New data can be set up
while the outputs are disabled.
The SN54AS250A is characterized for operation
over the full military temperature range of − 55°C
to 125°C. The SN74AS250A is characterized for
operation from 0°C to 70°C.
5
4 3 2 1 28 27 26
25
6
24
7
23
8
22
9
21
10
20
11
19
12 13 14 15 16 17 18
E10
E11
E12
NC
E13
E14
E15
W
D
GND
NC
C
B
A
E4
E3
E2
NC
E1
E0
OE
NC − No internal connection
Copyright 1994, Texas Instruments Incorporated
!"#$%&'(!$" !) *+%%,"( ') $# -+./!*'(!$" 0'(,1
%$0+*() *$"#$%& ($ )-,*!#!*'(!$") -,% (2, (,%&) $# ,3') ")(%+&,"()
)('"0'%0 4'%%'"(51 %$0+*(!$" -%$*,))!"6 0$,) "$( ",*,))'%!/5 !"*/+0,
(,)(!"6 $# '// -'%'&,(,%)1
• DALLAS, TEXAS 75265
• HOUSTON, TEXAS 77251−1443
POST OFFICE BOX 655303
POST OFFICE BOX 1443
1
SDAS137A − DECEMBER 1983 − REVISED DECEMBER 1994
logic symbol†
FUNCTION TABLE
INPUTS
OE
A
B
C
D
Ei
OUTPUT
W
9
OE
L
L
L
L
L
E0
E0
L
H
L
L
L
E1
E1
L
L
H
L
L
E2
E2
B
A
L
H
H
L
L
E3
E3
C
L
L
L
H
L
E4
E4
D
L
H
L
H
L
E5
E5
E0
L
L
H
H
L
E6
E6
E1
L
H
H
H
L
E7
E7
E2
L
L
L
L
H
E8
E8
E3
L
H
L
L
H
E9
E9
E4
L
L
H
L
H
E10
E10
E5
L
H
H
L
H
E11
E11
E6
L
L
L
H
H
E12
E12
L
H
L
H
H
E13
E13
L
L
H
H
H
E14
E14
L
H
H
H
H
E15
E15
H
X
X
X
X
X
Z
E7
E8
E9
E10
E11
E12
E13
E14
E15
15
MUX
EN
0
14
G
13
11
0
15
3
8
7
6
5
4
10
3
2
1
23
22
21
20
19
18
17
16
† This symbol is in accordance with ANSI/IEEE Std 91-1984 and
IEC Publication 617-12.
Pin numbers shown are for the DW, JT, and NT packages.
2
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
W
SDAS137A − DECEMBER 1983 − REVISED DECEMBER 1994
logic diagram (positive logic)
E0
E1
E2
E3
E4
E5
E6
E7
Data
Inputs
E8
E9
E10
E11
E12
E13
E14
E15
A
8
7
6
5
4
3
2
1
10
23
W
22
21
20
19
18
17
16
15
A
A
B
14
B
Data
Selects
B
C
13
C
C
D
11
D
D
OE
Pin numbers shown are for the DW, JT, and NT packages.
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
3
SDAS137A − DECEMBER 1983 − REVISED DECEMBER 1994
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Operating free-air temperature range, TA: SN54AS250A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −55°C to 125°C
SN74AS250A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54AS250A
SN74AS250A
MIN
NOM
MAX
MIN
NOM
MAX
4.5
5
5.5
4.5
5
5.5
UNIT
VCC
VIH
Supply voltage
VIL
IOH
Low-level input voltage
0.8
0.8
V
High-level output current
−12
−15
mA
IOL
TA
Low-level output current
48
mA
70
°C
High-level input voltage
2
2
V
32
Operating free-air temperature
−55
125
V
0
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
VIK
SN54AS250A
TYP‡
MAX
TEST CONDITIONS
MIN
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
II = − 18 mA
IOH = − 2 mA
VCC = 4.5 V
IOH = − 12 mA
IOH = − 15 mA
VOL
VCC = 4.5 V
IOL = 32 mA
IOL = 48 mA
IOZH
IOZL
VCC = 5.5 V,
VCC = 5.5 V,
VO = 2.7 V
VO = 0.4 V
II
IIH
VCC = 5.5 V,
VCC = 5.5 V,
VI = 7 V
VI = 2.7 V
IIL
IO§
VCC = 5.5 V,
VCC = 5.5 V,
VI = 0.4 V
VO = 2.25 V
VOH
ICC
VCC = 5.5 V
SN74AS250A
TYP‡
MAX
MIN
−1.2
VCC − 2
2.4
−1.2
UNIT
V
VCC − 2
3.3
V
2.4
0.35
3.3
0.5
0.35
−30
0.5
V
50
50
µA
−50
−50
µA
0.1
0.1
mA
20
20
µA
−0.5
−0.5
mA
−112
mA
−112
−30
Outputs high
26
42
26
42
Outputs low
31
50
31
50
mA
Outputs disabled
30
48
30
48
‡ All typical values are at VCC = 5 V, TA = 25°C.
§ The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS.
4
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
SDAS137A − DECEMBER 1983 − REVISED DECEMBER 1994
switching characteristics (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
Data
W
tPLH
tPHL
A, B, C, D
W
tPZH
tPZL
OE
W
tPHZ
tPLZ
OE
W
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
R1 = 500 Ω,
R2 = 500 Ω,
TA = MIN to MAX†
SN54AS250A SN74AS250A
MIN
MAX
MIN
MAX
2
9.5
2
8
2
8.5
2
7
4
15.5
4
13
4
12
4
10.5
2
7.5
2
7
2
10
2
9
1.5
6.5
1.5
6
2
8.5
2
6.5
UNIT
ns
ns
ns
ns
† For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
5
SDAS137A − DECEMBER 1983 − REVISED DECEMBER 1994
PARAMETER MEASUREMENT INFORMATION
SERIES 54ALS/74ALS AND 54AS/74AS DEVICES
7V
RL = R1 = R2
VCC
S1
RL
R1
Test
Point
From Output
Under Test
CL
(see Note A)
From Output
Under Test
RL
Test
Point
CL
(see Note A)
CL
(see Note A)
LOAD CIRCUIT FOR
BI-STATE
TOTEM-POLE OUTPUTS
LOAD CIRCUIT
FOR OPEN-COLLECTOR OUTPUTS
3.5 V
Timing
Input
Test
Point
From Output
Under Test
LOAD CIRCUIT
FOR 3-STATE OUTPUTS
3.5 V
High-Level
Pulse
1.3 V
R2
1.3 V
1.3 V
0.3 V
0.3 V
tsu
Data
Input
tw
th
3.5 V
1.3 V
3.5 V
Low-Level
Pulse
1.3 V
0.3 V
1.3 V
0.3 V
VOLTAGE WAVEFORMS
PULSE DURATIONS
VOLTAGE WAVEFORMS
SETUP AND HOLD TIMES
3.5 V
Output
Control
(low-level
enabling)
1.3 V
1.3 V
0.3 V
tPZL
Waveform 1
S1 Closed
(see Note B)
tPLZ
3.5 V
Input
tPZH
1.3 V
0.3 V
tPHL
tPLH
VOH
In-Phase
Output
VOL
0.3 V
1.3 V
1.3 V
VOL
tPLH
tPHL
VOH
1.3 V
1.3 V
[3.5 V
1.3 V
tPHZ
Waveform 2
S1 Open
(see Note B)
1.3 V
VOH
Out-of-Phase
Output
(see Note C)
0.3 V
[0 V
1.3 V
1.3 V
VOL
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS
NOTES: A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. When measuring propagation delay items of 3-state outputs, switch S1 is open.
D. All input pulses have the following characteristics: PRR ≤ 1 MHz, tr = tf = 2 ns, duty cycle = 50%.
E. The outputs are measured one at a time with one transition per measurement.
Figure 1. Load Circuits and Voltage Waveforms
6
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
PACKAGE OPTION ADDENDUM
www.ti.com
12-Apr-2022
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package Pins Package
Drawing
Qty
Eco Plan
(2)
Lead finish/
Ball material
MSL Peak Temp
Op Temp (°C)
(3)
Device Marking
(4/5)
(6)
5962-9056201LA
ACTIVE
CDIP
JT
24
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
5962-9056201LA
SNJ54AS250AJT
SNJ54AS250AJT
ACTIVE
CDIP
JT
24
1
Non-RoHS
& Green
SNPB
N / A for Pkg Type
-55 to 125
5962-9056201LA
SNJ54AS250AJT
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance
do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may
reference these types of products as "Pb-Free".
RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption.
Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of