0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TS3L100PW

TS3L100PW

  • 厂商:

    BURR-BROWN(德州仪器)

  • 封装:

    TSSOP16

  • 描述:

    Networking Switch IC 4 Channel 16-TSSOP

  • 数据手册
  • 价格&库存
TS3L100PW 数据手册
                  SCDS161A − MAY 2004 – REVISED OCTOBER 2004 D Wide Bandwidth (BW = 350 MHz Min) D Low Differential Crosstalk D Data and Control Inputs Have Undershoot (XTALK = −68 dB Typ) D Low Power Consumption (ICC = 10 mA Max) D Bidirectional Data Flow, With Near-Zero D 1 16 2 15 3 14 4 13 5 12 6 11 7 10 8 9 VCC E ID0 ID1 YD IC0 IC1 YC IA0 IA1 YA IB0 IB1 YB 1 16 15 E 14 ID0 2 3 13 ID1 12 YD 4 5 6 7 8 9 YC S IA0 IA1 YA IB0 IB1 YB GND VCC RGY PACKAGE (TOP VIEW) D, DBQ, DGV, OR PW PACKAGE (TOP VIEW) S D D D GND D D Propagation Delay Low ON-State Resistance (ron = 5 W Typ) Rail-to-Rail Switching on Data I/O Ports (0 to VCC) VCC Operating Range From 3 V to 3.6 V Ioff Supports Partial-Power-Down Mode Operation D Clamp Diodes Latch-Up Performance Exceeds 100 mA Per JESD 78, Class II ESD Performance Tested Per JESD 22 − 2000-V Human-Body Model (A114-B, Class II) − 1000-V Charged-Device Model (C101) Suitable for Both 10 Base-T/100 Base-T Signaling 11 IC0 10 IC1 description/ordering information The TI TS3L100 LAN switch is a 4-bit 1-of-2 multiplexer/demultiplexer with a single switch-enable (E) input. When E is low, the switch is enabled and the I port is connected to the Y port. When E is high, the switch is disabled and the high-impedance state exists between the I and Y ports. The select (S) input controls the data path of the multiplexer/demultiplexer. ORDERING INFORMATION QFN − RGY SOIC − D 0°C 0 C to 70 70°C C ORDERABLE PART NUMBER PACKAGE† TA SSOP (QSOP) − DBQ TSSOP − PW Tape and reel TS3L100RGYR Tube TS3L100D Tape and reel TS3L100DR Tape and reel TS3L100DBQR Tube TS3L100PW Tape and reel TS3L100PWR TOP-SIDE MARKING TK100 TS3L100 TK100 TK100 TVSOP − DGV Tape and reel TS3L100DGVR TK100 † Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are available at www.ti.com/sc/package. Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. Copyright  2004, Texas Instruments Incorporated       !"   #!$% &"' &!   #" #" (" "  ") !" && *+' &! #", &"  ""%+ %!&" ",  %% #""' POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 1                   SCDS161A − MAY 2004 – REVISED OCTOBER 2004 description/ordering information (continued) This device can be used to replace mechanical relays in LAN applications. This device has low ron, wide bandwidth, and low differential crosstalk, making it suitable for 10 Base-T, 100 Base-T, and various other LAN applications. This device is fully specified for partial-power-down applications using Ioff. The Ioff feature ensures that damaging current will not backflow through the device when it is powered down. The device has isolation during power off. To ensure the high-impedance state during power up or power down, E should be tied to VCC through a pullup resistor; the minimum value of the resistor is determined by the current-sinking capability of the driver. FUNCTION TABLE INPUTS E INPUT/OUTPUT YX S FUNCTION L L H IX0 IX1 YX = IX0 L H X Z Disconnect YX = IX1 PIN DESCRIPTIONS PIN NAME IAn−IDn S Select input E Enable input YA−YD 2 DESCRIPTION Data I/Os Data I/Os POST OFFICE BOX 655303 • DALLAS, TEXAS 75265                   SCDS161A − MAY 2004 – REVISED OCTOBER 2004 logic diagram (positive logic) 2 4 IA0 YA 3 IA1 YB 7 5 IB0 6 IB1 9 11 YC 10 YD 12 14 13 S IC0 IC1 ID0 ID1 1 15 Control Logic E POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 3                   SCDS161A − MAY 2004 – REVISED OCTOBER 2004 absolute maximum ratings over operating free-air temperature range (unless otherwise noted)† Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 4.6 V Control input voltage range, VIN (see Notes 1 and 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 4.6 V Switch I/O voltage range, VI/O (see Notes 1, 2, and 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 4.6 V Control input clamp current, IIK (VIN < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −50 mA I/O port clamp current, II/OK (VI/O < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −50 mA ON-state switch current, II/O (see Note 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±128 mA Continuous current through VCC or GND terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA Package thermal impedance, θJA (see Note 5): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73°C/W DB package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82°C/W DBQ package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90°C/W PW package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108°C/W Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. All voltages are with respect to ground, unless otherwise specified. 2. The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed. 3. VI and VO are used to denote specific conditions for VI/O. 4. II and IO are used to denote specific conditions for II/O. 5. The package thermal impedance is calculated in accordance with JESD 51-7. recommended operating conditions (see Note 6) MIN MAX VCC VIH Supply voltage 3 3.6 UNIT V High-level control input voltage (E, S) 2 Low-level control input voltage (E, S) 0 VCC 0.8 V VIL TA Operating free-air temperature 0 70 °C V NOTE 6: All unused control inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report, Implications of Slow or Floating CMOS Inputs, literature number SCBA004. 4 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265                   SCDS161A − MAY 2004 – REVISED OCTOBER 2004 electrical characteristics over recommended VCC = 3.3 V + 0.3 V (unless otherwise noted) PARAMETER VIK Vhys E, S IIH IIL E, S operating free-air TEST CONDITIONS IIN = −18 mA VCC = 3.6 V, VCC = 3.6 V, VIN = VCC VIN = GND TYP† MAX UNIT −1.8 V IOZ‡ VCC = 3.6 V, VO = 0 to 3.6 V, VI = 0, Switch OFF IOS§ VCC = 3.6 V, VO = 0 to 0.5 VCC, VI = 0, Switch ON Ioff ICC VCC = 0, VCC = 3.6 V, VO = 0 to 3.6 V, II/O = 0, VI = 0 Switch ON or OFF VCC = 3.6 V, One input at VCC − 0.6 V, Other inputs at VCC or GND E, S E, S E, S ICCD CIN range, MIN VCC = 3 V, ∆ICC temperature 150 VCC = 3.6 V, E, S I and Y ports open, µA ±1 µA ±1 µA 50 mA 0.1 VIN input switching 50% duty cycle f = 1 MHz I port mV ±1 15 µA 10 µA 750 µA 0.45 mA/ MHz 3 pF 5 VI = 0, f = 1 MHz, Outputs open, Switch OFF CON VI = 0, f = 1 MHz, Outputs open, Switch ON 17 IO = 48 mA 7 VCC = 3 V VI = 0 V, 5 ron VI = 2 V, IO = 15 mA 10 15 ∆ron VI = 3 V, Switch ON, IO = 15 mA 1 COFF Y port pF 10 pF Ω Ω VI, VO, II, and IO refer to I/O pins. VIN refers to the control inputs. † All typical values are at VCC = 3.3 V (unless otherwise noted), TA = 25°C. ‡ For I/O ports, the parameter IOZ includes the input leakage current. § The IOS test is applicable to only one ON channel at a time. The duration of this test is less than one second. switching characteristics over recommended operating free-air temperature range, VCC = 3.3 V + 0.3 V, RL = 100 Ω, CL = 35 pF (unless otherwise noted) (see Figure 4) PARAMETER tON FROM (INPUT) TO (OUTPUT) S tOFF S † All typical values are at VCC = 3.3 V (unless otherwise noted), TA = 25°C. dynamic characteristics over recommended VCC = 3.3 V + 0.3 V (unless otherwise noted) PARAMETER operating MIN MAX Y 1 7.5 ns Y 1 3.5 ns free-air TYP† TEST CONDITIONS XTALK(Diff) XTALK RL = 100 Ω, f = 10 MHz, see Figure 8, RL = 100 Ω, OIRR RL = 100 Ω, temperature range, UNIT −55 dB f = 30 MHz, see Figure 6 −68 dB f = 30 MHz, see Figure 7 −42 dB 350 MHz BW RL = 100 Ω, see Figure 5 † All typical values are at VCC = 3.3 V (unless otherwise noted), TA = 25°C. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 tr = tf = 2 ns UNIT 5                   SCDS161A − MAY 2004 – REVISED OCTOBER 2004 OPERATING CHARACTERISTICS 0 0 Phase −2 −20 −3 −30 Gain −4 −40 J −5 Y −50 −6 −60 −7 −70 −8 −80 −9 1 Y Gain 3 dB at 450 MHz 10 100 Frequency − MHz J Phase at 3-dB Frequency, −43 Degrees Figure 1. Gain/Phase vs Frequency 6 −10 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 −90 600 Phase − Deg Gain − dB −1                   SCDS161A − MAY 2004 – REVISED OCTOBER 2004 OPERATING CHARACTERISTICS Off Isolation − dB −10 140 −20 120 −30 100 Phase J −40 80 Y Phase − Deg 160 0 60 −50 Off Isolation −60 40 −70 20 −80 1 10 100 0 600 Frequency − MHz Y Off Isolation at 30 MHz, −44.6 dB J Phase at 30 MHz, 84.41 Degrees Figure 2. Off Isolation vs Frequency POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 7                   SCDS161A − MAY 2004 – REVISED OCTOBER 2004 OPERATING CHARACTERISTICS 0 250 −20 200 −40 150 Crosstalk 100 Y −80 50 −100 0 −120 −50 Phase −140 −100 J −160 −150 −180 −200 −200 1 10 100 Frequency − MHz Y Crosstalk at 30 MHz, −67.3 dB J Phase at 30 MHz, −118.4 Degrees Figure 3. Crosstalk vs Frequency 8 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 −250 600 Phase − Deg Crosstalk − dB −60                   SCDS161A − MAY 2004 – REVISED OCTOBER 2004 PARAMETER MEASUREMENT INFORMATION VCC Input Generator VS 50 Ω S 50 Ω VG1 IX0 DUT VX0 VO YX IX1 CL (see Note A) E RL VX1 TEST VCC RL CL VX0 VX1 tON 3.3 V + 0.3 V 3.3 V + 0.3 V 100 Ω 100 Ω 35 pF 35 pF GND 3V 3V GND tOFF 3.3 V + 0.3 V 3.3 V + 0.3 V 100 Ω 100 Ω 35 pF 35 pF GND 3V 3V GND TEST CIRCUIT 3V Output Control (VS) 50% 50% 0V tON Analog Output Waveform (VO) tOFF 90% 90% VOH 0V VOLTAGE WAVEFORMS tON AND tOFF TIMES NOTES: A. CL includes probe and jig capacitance. B. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr ≤ 2.5 ns, tf ≤ 2.5 ns. C. The outputs are measured one at a time, with one transition per measurement. Figure 4. Test Circuit and Voltage Waveforms POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 9                   SCDS161A − MAY 2004 – REVISED OCTOBER 2004 PARAMETER MEASUREMENT INFORMATION EXT TRIGGER BIAS Network Analyzer (HP8753ES) VBIAS P1 P2 VCC IA0 YA RL = 100 Ω S DUT VS E VE Figure 5. Test Circuit for Frequency Response (BW) Frequency response is measured at the output of the ON channel. For example, when VS = 0, VE = 0, and YA is the input, the output is measured at IA0. All unused analog I/O ports are left open. HP8753ES setup Average = 4 RBW = 3 kHz VBIAS = 0.35 V ST = 2 s P1 = 0 dBM 10 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265                   SCDS161A − MAY 2004 – REVISED OCTOBER 2004 PARAMETER MEASUREMENT INFORMATION EXT TRIGGER BIAS Network Analyzer (HP8753ES) VBIAS P1 P2 VCC YA IA0 RL = 100 Ω S 50 Ω† VS E DUT VE YB IB0 RL = 100 Ω † A 50-Ω termination resistor is needed for the network analyzer. Figure 6. Test Circuit for Crosstalk (XTALK) Crosstalk is measured at the output of the nonadjacent ON channel. For example, when VS = 0, VE = 0, and YA is the input, the output is measured at IB0. All unused analog input (Y) ports are connected to GND and output (I) ports are connected to GND through 50-Ω pulldown resistors. HP8753ES setup Average = 4 RBW = 3 kHz VBIAS = 0.35 V ST = 2 s P1 = 0 dBM POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 11                   SCDS161A − MAY 2004 – REVISED OCTOBER 2004 PARAMETER MEASUREMENT INFORMATION EXT TRIGGER BIAS Network Analyzer (HP8753ES) VBIAS P1 P2 VCC IA0 YA RL = 100 Ω S DUT VS IA1 E RL = 100 Ω 50 Ω† VE † A 50-Ω termination resistor is needed for the network analyzer. Figure 7. Test Circuit for Off Isolation (OIRR) OFF isolation is measured at the output of the OFF channel. For example, when VS = VCC, VE = 0, and YA is the input, the output is measured at IA0. All unused analog input (Y) ports are left open and output (I) ports are connected to GND through 50-Ω pulldown resistors. HP8753ES setup Average = 4 RBW = 3 kHz VBIAS = 0.35 V ST = 2 s P1 = 0 dBM 12 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265                   SCDS161A − MAY 2004 – REVISED OCTOBER 2004 PARAMETER MEASUREMENT INFORMATION VCC = 3.3 V 0.1 µF Oscilloscope S VO+ 16 IA0 2 15 IA1 3 14 ID0 4 13 ID1 YA 100 Ω 100 Ω VO− VCC 1 TS3L100 E YD IB0 5 12 IB1 6 11 IC0 7 10 IC1 8 9 YB GND VI+ 100 Ω YC 100 Ω Pulse Generator VI− Figure 8. Differential Crosstalk Measurement Differential crosstalk is a measure of coupling noise between a transmit and receive pair in the LAN application. Differential crosstalk depends on the edge rate, frequency, and load. This is calculated from the equation, XTALK(Diff) db = 20 log VO(Diff)/VI(Diff), where VO(Diff) is the differential output voltage and VI(Diff) is the differential input voltage. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 13 PACKAGE OPTION ADDENDUM www.ti.com 14-Oct-2022 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan (2) Lead finish/ Ball material MSL Peak Temp Op Temp (°C) Device Marking (3) Samples (4/5) (6) TS3L100DBQR ACTIVE SSOP DBQ 16 2500 RoHS & Green NIPDAU Level-2-260C-1 YEAR 0 to 70 TK100 Samples TS3L100DGVR ACTIVE TVSOP DGV 16 2000 RoHS & Green NIPDAU Level-1-260C-UNLIM 0 to 70 TK100 Samples TS3L100DR ACTIVE SOIC D 16 2500 RoHS & Green NIPDAU Level-1-260C-UNLIM 0 to 70 TS3L100 Samples TS3L100PW ACTIVE TSSOP PW 16 90 RoHS & Green NIPDAU Level-1-260C-UNLIM 0 to 70 TK100 Samples TS3L100PWR ACTIVE TSSOP PW 16 2000 RoHS & Green NIPDAU Level-1-260C-UNLIM 0 to 70 TK100 Samples TS3L100RGYR ACTIVE VQFN RGY 16 3000 RoHS & Green NIPDAU Level-2-260C-1 YEAR 0 to 70 TK100 Samples (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may reference these types of products as "Pb-Free". RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption. Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of
TS3L100PW 价格&库存

很抱歉,暂时无法提供与“TS3L100PW”相匹配的价格&库存,您可以联系我们找货

免费人工找货