Additional Resources:
Product Page
|
3D Model
date
02/01/2023
page
1 of 6
SERIES: SWH24-N │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
universal input voltage range
over current and short circuit protections
UL 1310 compliant
for household appliances
custom designs available
North American fixed blade
MODEL
input
voltage
input
frequency
output
voltage
output
current
output
power
ripple
and
noise1
range
(Vac)
range
(Hz)
nom
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
average2
(%)
10%
(%)
max
(W)
SWH24-5-N
90 ~ 264
47 ~ 63
5
3.0
15
240
81.9
70.0
0.1
SWH24-8-N
90 ~ 264
47 ~ 63
8
2.5
20
240
85.47
70.0
0.1
SWH24-9-N
90 ~ 264
47 ~ 63
9
2.0
18
240
85.0
70.0
0.1
SWH24-11-N
90 ~ 264
47 ~ 63
11
2.2
24.2
240
86.24
70.0
0.1
SWH24-12-N
90 ~ 264
47 ~ 63
12
2.0
24
240
86.2
70.0
0.1
SWH24-15-N
90 ~ 264
47 ~ 63
15
1.5
22.5
240
85.96
70.0
0.1
SWH24-18-N
90 ~ 264
47 ~ 63
18
1.25
22.5
240
85.96
70.0
0.1
SWH24-19-N
90 ~ 264
47 ~ 63
19
1.25
23.75
240
86.17
70.0
0.1
SWH24-24-N
90 ~ 264
47 ~ 63
24
1.0
24.0
240
86.2
70.0
0.1
SWH24-28-N
90 ~ 264
47 ~ 63
28
0.85
23.8
240
86.17
70.0
0.1
SWH24-36-N
90 ~ 264
47 ~ 63
36
0.65
23.4
240
86.11
70.0
0.1
Notes:
efficiency
level
no load power
consumption
1. At full load, nominal AC input voltage, 25°C, 20 MHz bandwidth oscilloscope, output terminated with 0.1 µF and 10 µF capacitors to ground.
2. Average efficiency is measured at 25%, 50%, 75%, and 100% load at 115 Vac & 230 Vac input.
PART NUMBER KEY
SWH24 - XX - NX- XXX - CXX
Reserved for Custom
Configurations
Base Number
Output Voltage
AC Input Type:
North America
Case Color:
B = black
W = white
cui.com
DC Plug Type:
XXX = See output plug options
on page 5 for more details
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWH24-N │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/01/2023 │ page 2 of 6
INPUT
parameter
conditions/description
min
voltage
typ
90
frequency
47
current
at full load
inrush current
at 240 Vac
leakage current
at 240 Vac, 50 Hz
no load power consumption
max
units
264
Vac
63
Hz
0.8
A
60
A
0.25
mA
0.1
W
max
units
OUTPUT
parameter
conditions/description
min
typ
line regulation
±1
%
load regulation
±5
%
start-up time
at 100 and 240 Vac, full load
hold-up time
at 115 Vac/60 Hz
at 230 Vac/50 Hz
3
1
3
s
ms
ms
PROTECTIONS
parameter
conditions/description
over current protection
auto recovery, hiccup
short circuit protection
auto recovery
min
typ
max
units
min
typ
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
isolation voltage
input to output at 10 mA for 1 minute
safety approvals
UL 1310
EMI/EMC
FCC Part 15B (Class B)
MTBF
at full load, 25°C
RoHS
yes
3,000
Vac
50,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
max
units
0
40
°C
storage temperature
-20
70
°C
operating humidity
10
95
%
5
95
%
operating temperature
storage humidity
cui.com
typ
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWH24-N │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/01/2023 │ page 3 of 6
MECHANICAL
parameter
conditions/description
dimensions
69.48 x 44.38 x 35.8
inlet plug
North America, 2 pin
min
typ
max
units
mm
weight
80
MECHANICAL DRAWING
units: mm
cui.com
g
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWH24-N │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/01/2023 │ page 4 of 6
DC CORD
units: mm
70±15
Table 1
CABLE
CORD LENGTH
SWH24-5-N
MODEL NO.
UL2468, 18 AWG
1,830 mm ±100
SWH24-8-N
UL2468, 20 AWG
1,830 mm ±100
SWH24-9-N
UL2468, 20 AWG
1,830 mm ±100
SWH24-11-N
UL2468, 20 AWG
1,830 mm ±100
SWH24-12-N
UL2468, 20 AWG
1,830 mm ±100
SWH24-15-N
UL2468, 20 AWG
1,830 mm ±100
SWH24-18-N
UL2468, 20 AWG
1,830 mm ±100
SWH24-19-N
UL2468, 20 AWG
1,830 mm ±100
SWH24-24-N
UL2468, 20 AWG
1,830 mm ±100
SWH24-28-N
UL2468, 20 AWG
1,830 mm ±100
SWH24-36-N
UL2468, 20 AWG
1,830 mm ±100
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWH24-N │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/01/2023 │ page 5 of 6
DC PLUG TYPE PART NUMBER KEY
XXX
Plug Polarity:
P = Center Positive
Plug Code:
X = Choose a code from the
options below
Plug Angle:
“blank” = Straight
R = Right Angle
N = Center Negative
Plug Polarity
Code
Dimensions (mm)
Plug Angle
Center Pos.
Center Neg.
Option
Type
A
B
C
Straight
Right
●
●
5
Standard
5.5
2.1
9.5
●
●
●
●
6
Standard
5.5
2.5
9.5
●
●
●
●
7
Standard
3.5
1.35
9.5
●
●
●
●
10
Locking2
5.5
2.1
9.5
●
N/A
●
●
11
Locking2
5.5
2.5
9.5
●
N/A
●
●
12
EIAJ-1
2.35
0.7
9.5
●
●
●
●
13
EIAJ-2
4.0
1.7
9.5
●
●
●
●
14
EIAJ-3
4.75
1.7
9.5
●
●
N/A
N/A
ST
●
N/A
N/A
N/A
CUB
USB
USB Type C
●
N/A
N/A
MUB
USB
Micro USB Type B
●
N/A
1. Contact CUI for additional plug options.
2. Maximum insertion depth is 10mm.
EIAJ
C
Straight
Locking
C
A
B
A
C
Straight
Right Angle (R)
Stripped & Tinned
Right Angle (R)
USB
5.8±0.5
6.7±0.3
20±5
9±2
VBUS: A4,A9,B4,B9
GND: A1,A12,B1,B12
A
B
C
C
B
A
A
B
Standard
B
N/A
Note:
Stripped and Tinned
USB Type C
cui.com
P5(-)
P1(+)
Micro USB Type B
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: SWH24-N │ DESCRIPTION: AC-DC POWER SUPPLY
date 02/01/2023 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
12/19/2022
1.01
dc cord updated for 5V model
01/09/2023
1.02
stripped and tinned option added to dc plug types
01/18/2023
dc cord & mechanical drawing updated, UL/CUL mark added
02/01/2023
1.03
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.