0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
VESD1-S12-D12-SIP

VESD1-S12-D12-SIP

  • 厂商:

    CUI

  • 封装:

    SIP7_5Pin Module

  • 描述:

    CONVERTER DC/DC +/-12V OUT 1W

  • 数据手册
  • 价格&库存
VESD1-S12-D12-SIP 数据手册
Additional Resources: Product Page date 03/08/2013 page 1 of 5 SERIES: VESD1-SIP │ DESCRIPTION: DC-DC CONVERTER 1 W isolated output industry standard 7 pin SIP package dual unregulated outputs 3,000 V isolation short circuit protection UL safety approvals (some models) wide temperature (-40~85°C) efficiency up to 81% N U • • • • • • • • ED FEATURES MODEL input voltage typ (Vdc) VESD1-S5-D9-SIP VESD1-S5-D12-SIP VESD1-S5-D15-SIP VESD1-S12-D5-SIP 5 output current efficiency range (Vdc) (Vdc) min (mA) max (mA) typ (%) 4.5 ~ 5.5 ±5 ±10 ±100 72 UL 60950 YES 4.5 ~ 5.5 ±9 ±6 ±56 75 YES 4.5 ~ 5.5 ±12 ±5 ±42 78 YES 5 4.5 ~ 5.5 ±15 ±4 ±33 79 YES 12 10.8 ~ 13.2 ±5 ±10 ±100 74 YES 5 12 10.8 ~ 13.2 ±9 ±6 ±56 76 YES 12 10.8 ~ 13.2 ±12 ±5 ±42 79 YES O VESD1-S12-D9-SIP 5 output voltage N VESD1-S5-D5-SIP TI RoHS ±15 15 13.5 ~ 16.5 ±9 ±6 ±56 75 NO VESD1-S15-D12-SIP 15 13.5 ~ 16.5 ±12 ±5 ±42 79 NO VESD1-S15-D15-SIP 15 13.5 ~ 16.5 ±15 ±4 ±33 79 NO VESD1-S24-D5-SIP 24 21.6 ~ 26.4 ±5 ±10 ±100 74 YES VESD1-S12-D12-SIP VESD1-S12-D15-SIP VESD1-S15-D5-SIP 10.8 ~ 13.2 ±4 ±33 80 YES 13.5 ~ 16.5 ±5 ±10 ±100 74 NO IS C VESD1-S15-D9-SIP 12 15 24 21.6 ~ 26.4 ±9 ±6 ±56 76 YES 24 21.6 ~ 26.4 ±12 ±5 ±42 80 YES VESD1-S24-D15-SIP 24 21.6 ~ 26.4 ±15 ±4 ±33 81 YES D VESD1-S24-D9-SIP VESD1-S24-D12-SIP VESD1-S XX -D XX -SIP Base Number Input Voltage cui.com Output Voltage Additional Resources: Product Page CUI Inc │ SERIES: VESD1-SIP │ DESCRIPTION: DC-DC CONVERTER date 03/08/2013 │ page 2 of 5 INPUT conditions/description min typ max units operating input voltage 5 V model 12 V model 15 V model 24 V model 4.5 10.8 13.5 21.6 5 12 15 24 5.5 13.2 16.5 26.4 Vdc Vdc Vdc Vdc min typ max units 1.2 % 15 % 150 mVp-p OUTPUT conditions/description for Vin change of 1% load regulation measured from 10% to full load voltage accuracy see tolerance envelope graph output ripple 20 MHz bandwidth switching frequency 100% load, input voltage range 10 U parameter line regulation 100 100 parameter conditions/description SAFETY AND COMPLIANCE conditions/description isolation voltage tested for 1 minute safety approvals UL 60950 insulation resistance at 500 Vdc RoHS compliant yes parameter O ENVIRONMENTAL min N parameter MTBF min TI short circuit protection N temperature coefficient PROTECTIONS ED parameter conditions/description typ typ kHz ±0.03 %/°C max units 1 s max units 3,000 Vdc 1,000 MΩ 3,500,000 hours min typ max units case operating temperature -40 85 °C storage temperature -55 125 °C 95 % 25 °C 300 °C non-condensing IS C storage humidity 100% load lead temperature 1.5 mm from the case for 10 seconds 15 D temperature rise cui.com Additional Resources: Product Page CUI Inc │ SERIES: VESD1-SIP │ DESCRIPTION: DC-DC CONVERTER date 03/08/2013 │ page 3 of 5 DERATING CURVES ED Load (%) 100 80 60 40 20 -40 -20 0 20 40 60 85 100 120 U Ambient Temperature (°C) MECHANICAL conditions/description 19.60 x 10.00 x 6.0 (0.77 x 0.39 x 0.24 inch) case material plastic UL94-V0 MECHANICAL DRAWING N Units: mm All pins on a 2.54mm pitch All pin diameters are 0.50mm Side View D 2.00 2.54 O 1 2 2.1 5 6 7 5 6 7 IS C 1 2 1 2 5 6 7 2.54 PIN CONNECTIONS 1 6.00 15.24 Bottom View cui.com units mm 1.00 + 0.15/-0 4.10 1.25 max Recommended Footprint 19.60 10.00 typ TI weight min N parameter dimensions +Vin 2 -Vin 5 -Vout 6 COM 7 +Vout g Additional Resources: Product Page CUI Inc │ SERIES: VESD1-SIP │ DESCRIPTION: DC-DC CONVERTER date 03/08/2013 │ page 4 of 5 APPLICATION NOTES ED 1. Requirement on Output Load In order to ensure the product operates efficiently and reliably, make sure the specified range of input voltage is not exceeded and the minimum output load is not less than 10% load. If the actual load is less than the specified minimum load, the output ripple may increase sharply while its efficiency and reliability will reduce greatly. If the actual output power is very small, please add an appropriate resistor as extra loading. 2. Overload Protection Under normal operating conditions, the output circuit of these products has no protection against over-current and short-circuits. The simplest method is to connect a self-recovery fuse in series at the input end or add a circuit breaker to the circuit. N Figure 1 L L +Vin U 3. Filtering In some circuits which are sensitive to noise and ripple, a filtering capacitor may be added to the DC/DC output end and input end to reduce the noise and ripple. However, the capacitance of the output filter capacitor must be proper. If the capacitance is too big, a startup problem might arise. For every channel of output, provided the safe and reliable operation is ensured, the greatest capacitance of its filter capacitor sees the external capacitor table. To get an extremely low ripple, an “LC” filtering network may be connected to the input and output ends of the DC/DC converter, which may produce a more significant filtering effect. It should also be noted that the inductance and the frequency of the “LC” filtering network should be staggered with the DC/DC frequency to avoid mutual interference (Figure 1). DC DC C L COM C -Vout TI -Vin +Vout C 4. Output Voltage Regulation and Over-voltage Protection Circuit The simplest device for output voltage regulation, over-voltage and over-current protection is a linear voltage regulator with overheat protection that is connected to the input or output end in series (Figure 2). REG +Vout N +Vin Figure 2 -Vin O +Vin DC DC COM -Vout REG DC DC -Vin +Vout COM REG -Vout IS C 5. External Capacitor Table It is not recommended to connect any external capacitor in the application field with less than 0.5 W output. Cout (µF) Vout (Vdc) Cout (µF) 5 4.7 5 4.7 12 2.2 9 2.2 24 1 12 1 -- -- 15 0.47 D Table 1 Vin (Vdc) cui.com Additional Resources: Product Page CUI Inc │ SERIES: VESD1-SIP │ DESCRIPTION: DC-DC CONVERTER date 03/08/2013 │ page 5 of 5 REVISION HISTORY description date 12/09/2010 1.0 initial release 1.01 template update 1.02 V-Infinity branding removed 1.03 updated spec ED rev. 02/02/2012 09/06/2012 03/08/2013 D IS C O N TI N U The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
VESD1-S12-D12-SIP 价格&库存

很抱歉,暂时无法提供与“VESD1-S12-D12-SIP”相匹配的价格&库存,您可以联系我们找货

免费人工找货