0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
VGS-150B-24

VGS-150B-24

  • 厂商:

    CUI

  • 封装:

  • 描述:

    封闭式 AC DC 转换器 1 输出 24V 88 ~ 132 VAC,176 ~ 264 VAC 输入

  • 数据手册
  • 价格&库存
VGS-150B-24 数据手册
Additional Resources: Product Page | 3D Model date 01/25/2021 page 1 of 5 SERIES: VGS-150B │ DESCRIPTION: AC-DC POWER SUPPLY FEATURES • • • • • • • +70°C operation output trim current/voltage/temperature protections screw terminal interface switch-selectable AC input range low standby power consumption 30 mm height MODEL output voltage output current output power ripple and noise1 efficiency2 (Vdc) max (A) max (W) max (mVp-p) typ (%) VGS-150B-12 12 12.5 150 100 86 VGS-150B-24 24 6.5 156 100 88 VGS-150B-48 48 3.2 153.6 200 88 Notes: 1. 20 MHz bandwidth oscilloscope, 12” of twisted load cables paralleled with 0.1 µF ceramic and 47 µF electrolytic capacitors placed across the terminals at the load. 2. At 230 Vac, 50 Hz, full load. 3. All specifications are measured at Ta=25°C, nominal input voltage, and rated output load unless otherwise specified. PART NUMBER KEY VGS-150B - XX Base Number Output Voltage cui.com Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VGS-150B │ DESCRIPTION: AC-DC POWER SUPPLY date 01/25/2021 │ page 2 of 5 INPUT parameter voltage conditions/description min typ max units via input selector switch1 88 176 115 230 132 264 Vac Vac 63 Hz 3.0 1.7 A A frequency 47 current at 115 Vac, full load at 230 Vac, full load inrush current at 230 Vac, cold start, full load leakage current no load power consumption Notes: at 230 Vac 40 A 3.5 mA 0.5 W 1. Input selector must be set to match input voltage or damage could occur. OUTPUT parameter conditions/description max units line regulation 48 Vdc output model all other models min typ ±0.5 ±1 % % load regulation 12 Vdc output model 24 Vdc output model 48 Vdc output model ±2 ±1 ±0.5 % % % adjustability built in trim pot start-up time at 115/230 Vac, full load rise time at 115/230 Vac, full load hold-up time at 115/230 Vac, full load ±10 % 0.5 s 80 ms 20 switching frequency ms 65 kHz PROTECTIONS parameter conditions/description min over voltage protection output shutdown, must recycle power to recover over current protection output shutdown, auto recovery short circuit protection output shutdown, auto recovery typ max units 110 150 % 110 150 % max units SAFETY & COMPLIANCE parameter conditions/description isolation voltage input to output for 1 minute, 10 mA input to ground for 1 minute, 10 mA output to ground for 1 minute, 10 mA isolation resistance input to output at 500 Vdc input to ground at 500 Vdc output to ground 500 Vdc safety approvals certified to 62368: EN certified to 60950: IEC/UL safety class class I conducted emissions EN 55032:2015, Class B radiated emissions EN 55032:2015, Class B input current harmonics EN 61000-3-2:2014, Class A voltage fluctuation and flicker EN 61000-3-3:2013, Class A ESD immunity IEC 61000-4-2, air: ±8 kV; contact: ±4 kV, Class A radiated field immunity IEC 61000-4-3, 3 V/m, Class A electrical fast transient immunity IEC 61000-4-4, Ac power port: 1 kV; signal & telecommunication ports: 0.5 kV, Class B Notes: min typ 1,500 1,500 500 100 100 100 Vac Vac Vac MΩ MΩ MΩ 2. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives. cui.com Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VGS-150B │ DESCRIPTION: AC-DC POWER SUPPLY date 01/25/2021 │ page 3 of 5 SAFETY & COMPLIANCE (CONTINUED) parameter conditions/description surge immunity IEC 61000-4-5, input L to input N: 1 kV; input L to FG: 2 kV; input N to FG: 2 kV, Class C conducted immunity IEC 61000-4-6, frequency range: 0.15~80 MHz; field strength: 3 Vms, Class A magnetic field immunity IEC 61000-4-8, 1 A/m, Class A voltage dips, interruptions IEC 61000-4-11: voltage dips >95% reduction, 0.5 period, Class A voltage dips 30% reduction, 25 period, Class B voltage dips >95% reduction, 250 period, Class C MTBF as per MIL-HDBK-217F, 25°C RoHS min typ max units 200,000 hours yes Notes: 1. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives. ENVIRONMENTAL parameter conditions/description min operating temperature see derating curves storage temperature typ max units -20 70 °C -40 85 °C operating humidity non-condensing 20 90 % storage humidity non-condensing 10 95 % DERATING CURVES Output Load vs. Input Voltage (at 25°C, Natural Convection) Output Load vs. Ambient Temperature (Natural Convection) 100 Output Load (%) Output Load (%) 100 90 80 60 40 60 40 20 20 0 88 176 80 0 -20 100 200 110 220 120 240 132 264 Input (Vac) cui.com 0 10 20 30 40 50 Ambient Temperature (°C) 60 70 Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VGS-150B │ DESCRIPTION: AC-DC POWER SUPPLY date 01/25/2021 │ page 4 of 5 MECHANICAL parameter conditions/description dimensions 159 x 97 x 30 min typ max mm weight 500 cooling natural convection input/output connector screw terminals accept 22~12 AWG wire, 1.2 N-m torque g MECHANICAL DRAWING units: mm tolerance: ±0.3 mm Input/Output Connector Input Selector Switch I/P & O /P Connector f  Function AC(L) 2 AC(N) A C (L) 3 FG AC(N) 4 -V (F G ) 5 -V -V 6 +V -V 7 +V +V f  1   PIN +V Max Depth Torque M3X0.5 4 mm
VGS-150B-24 价格&库存

很抱歉,暂时无法提供与“VGS-150B-24”相匹配的价格&库存,您可以联系我们找货

免费人工找货