0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
VMS-130-36-BP

VMS-130-36-BP

  • 厂商:

    CUI

  • 封装:

  • 描述:

    开放框架 AC DC 转换器 1 输出 36V 80 ~ 264 VAC 输入

  • 数据手册
  • 价格&库存
VMS-130-36-BP 数据手册
Additional Resources: Product Page | 3D Model date 05/04/2023 page 1 of 7 SERIES: VMS-130 │ DESCRIPTION: AC-DC POWER SUPPLY FEATURES • • • • • • • 80 ~ 264 Vac input voltage range 2” x 3” open frame chassis 100 W power output with natural convection 130 W power output with forced air cooling active PFC IEC 60601-1 approved IEC Class I & Class II safety approved MODEL output voltage output current1 output power2 ripple and noise3 efficiency4 (Vdc) max (A) max (W) max (mVp-p) typ (%) VMS-130-12 12 10.8 130 120 93 VMS-130-24 24 5.4 130 240 93 VMS-130-36 36 3.6 130 360 94 VMS-130-48 48 2.7 130 480 94 Notes: 1. 2. 3. 4. Maximum output power of 130 W with 10 CFM forced air cooling, and 100 W with natural convection. See derating curves. With forced air (10 CFM). At full load, nominal input, 20 MHz bandwidth oscilloscope with 10 µF electrolytic and 0.1 µF ceramic capacitors. At 230 Vac, 25°C, 75% load. PART NUMBER KEY VMS-130 - XX - XXX Base Number Output Voltage cui.com Chassis: “blank” = open-frame BP = base plate CNF = covered Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VMS-130 │ DESCRIPTION: AC-DC POWER SUPPLY date 05/04/2023 │ page 2 of 7 INPUT parameter conditions/description min voltage typ 80 frequency 47 max units 264 Vac 63 Hz current at 240 Vac at 100 Vac 0.8 1.5 A A inrush current at 240 Vac, cold start 100 A 0.1 mA max units leakage current OUTPUT parameter conditions/description initial set point accuracy at full load line regulation 100 ~ 240 Vac, full load load regulation 10 ~ 100% load hold-up time at 230 Vac, 25°C min typ ±2 % ±0.5 % ±1 % 20 temperature coefficient switching frequency ms ±0.05 %/°C 105 kHz PROTECTIONS parameter conditions/description over voltage protection auto recovery 12 Vdc output 24 Vdc output 36 Vdc output 48 Vdc output short circuit protection auto recovery, hiccup min typ model model model model max units 13.5 30 42 54 Vdc Vdc Vdc Vdc max units SAFETY & COMPLIANCE parameter conditions/description min isolation voltage input to output safety approvals certified to 60601: IEC/EN/UL safety class class I, class II conducted emissions EN55011 Class B when test condition is Class Ι, Class II radiated emissions EN55011 Class B when test condition is Class Ι EN55011 Class A when test condition is Class II harmonic current IEC 61000-3-2 voltage fluctuations and flicker IEC 61000-3-3:2013 ESD IEC 61000-4-2 radiated immunity IEC 61000-4-3 EFT/burst IEC 61000-4-4 surge IEC 61000-4-5 conducted immunity IEC 61000-4-6 voltage dips and interruptions IEC 61000-4-11 MTBF as per MIL-HDBK-217F at 25°C RoHS yes 4,000 400,000 cui.com typ Vac hours Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VMS-130 │ DESCRIPTION: AC-DC POWER SUPPLY date 05/04/2023 │ page 3 of 7 ENVIRONMENTAL parameter conditions/description min max units operating temperature see derating curve -30 70 °C -40 85 °C 93 % storage temperature operating humidity non-condensing DERATING CURVES cui.com typ Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VMS-130 │ DESCRIPTION: AC-DC POWER SUPPLY date 05/04/2023 │ page 4 of 7 MECHANICAL parameter conditions/description dimensions open frame models: 3.000 x 2.000 x 1.200 [76.2 x 50.8 x 30.5 mm] base plate models: 3.598 x 2.000 x 1.299 [91.4 x 50.8 x 33.0 mm] covered models: 3.598 × 2.520 × 1.358 [91.4 x 64.0 x 34.5 mm] min weight open frame models base plate models covered models 135 170 218 g g g cooling natural convection (no integrated fan), see derating curve 10 CFM 100 130 W W MECHANICAL DRAWING Open-frame units: inch [mm] general tolerance: ±0.02 [±0.5] PIN-OUT PIN Function 1 AC (L) 2 AC (N) 3 -Vo 4 -Vo 5 +Vo 6 +Vo cui.com typ max units inches inches inches Additional Resources: Product Page CUI Inc │ SERIES: VMS-130 │ DESCRIPTION: AC-DC POWER SUPPLY Base plate units: inch [mm] general tolerance: ±0.02 [±0.5] PIN-OUT Function 1 AC (L) 2 AC (N) 3 -Vo 4 -Vo 5 +Vo 6 +Vo 3D Model date 05/04/2023 │ page 5 of 7 MECHANICAL DRAWING (CONTINUED) PIN | cui.com Additional Resources: Product Page CUI Inc │ SERIES: VMS-130 │ DESCRIPTION: AC-DC POWER SUPPLY Covered units: inch [mm] general tolerance: ±0.02 [±0.5] PIN-OUT Function 1 AC (L) 2 AC (N) 3 -Vo 4 -Vo 5 +Vo 6 +Vo 3D Model date 05/04/2023 │ page 6 of 7 MECHANICAL DRAWING (CONTINUED) PIN | cui.com Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VMS-130 │ DESCRIPTION: AC-DC POWER SUPPLY date 05/04/2023 │ page 7 of 7 REVISION HISTORY rev. description date 1.0 initial release 11/09/2021 1.01 mechanical drawing updated 07/13/2022 1.02 medical icon added 05/04/2023 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
VMS-130-36-BP 价格&库存

很抱歉,暂时无法提供与“VMS-130-36-BP”相匹配的价格&库存,您可以联系我们找货

免费人工找货
VMS-130-36-BP
    •  国内价格
    • 1+578.71752

    库存:16