0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
VOF-130-36-BP

VOF-130-36-BP

  • 厂商:

    CUI

  • 封装:

  • 描述:

    开放框架 AC DC 转换器 1 输出 36V 80 ~ 264 VAC 输入

  • 数据手册
  • 价格&库存
VOF-130-36-BP 数据手册
Additional Resources: Product Page | 3D Model date 11/08/2021 page 1 of 7 SERIES: VOF-130 │ DESCRIPTION: AC-DC POWER SUPPLY FEATURES • • • • • • • 80 ~ 264 Vac input voltage range 2” x 3” open frame chassis 100 W power output with natural convection 130 W power output with forced air cooling active PFC IEC 62368-1 approved IEC Class I & Class II safety approved MODEL output voltage output current1 output power2 ripple and noise3 efficiency4 (Vdc) max (A) max (W) max (mVp-p) typ (%) VOF-130-12 12 10.8 130 120 93 VOF-130-24 24 5.4 130 240 93 VOF-130-36 36 3.6 130 360 94 VOF-130-48 48 2.7 130 480 94 Notes: 1. 2. 3. 4. Maximum output power of 130 W with 10 CFM forced air cooling, and 100 W with natural convection. See derating curves. With forced air (10 CFM). At full load, nominal input, 20 MHz bandwidth oscilloscope with 10 µF electrolytic and 0.1 µF ceramic capacitors. At 230 Vac, 25°C, 75% load. PART NUMBER KEY VOF-130 - XX - XXX Base Number Output Voltage cui.com Chassis: “blank” = open-frame BP = base plate CNF = covered Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VOF-130 │ DESCRIPTION: AC-DC POWER SUPPLY date 11/08/2021 │ page 2 of 7 INPUT parameter conditions/description min voltage typ 80 frequency max units 264 Vac 60 Hz current at 100 Vac, full load 47 1.8 A inrush current at 240 Vac, cold start 100 A 0.1 mA leakage current OUTPUT parameter conditions/description output capacitance 12 24 36 48 initial set point accuracy at full load line regulation 100 ~ 240 Vac, full load load regulation 10 ~ 100% load hold-up time at 115 Vac, 25°C Vdc Vdc Vdc Vdc output output output output min typ model model model model max units 8,400 4,200 2,720 2,040 µF µF µF µF ±2 % ±0.5 % ±1 switching frequency % 20 ms 105 kHz PROTECTIONS parameter conditions/description over voltage protection auto recovery 12 Vdc output 24 Vdc output 36 Vdc output 48 Vdc output over current protection auto recovery short circuit protection auto recovery min model model model model typ max 13.5 30 42 54 units Vdc Vdc Vdc Vdc 115 130 145 % min typ max units SAFETY & COMPLIANCE parameter conditions/description isolation voltage input to output, for 1 minute input to ground, for 1 minute output to ground, for 1 minute safety approvals certified to 62368: IEC/EN/UL safety class class I, class II conducted emissions EN 55032, 47 CFR FCC Part 15 (Class I & Class II meets Class B) radiated emissions EN 55032, 47 CFR FCC Part 15 (Class I Meet Class B; Class II Meet Class A) harmonic current EN 61000-3-2:2014 voltage fluctuations and flicker 3,000 1,500 500 Vac Vac Vac EN 61000-3-3:2013 ESD IEC 61000-4-2:2008 Air Discharge: ±8kV, Contact Discharge: ±4kV, perf. Criteria A radiated immunity IEC 61000-4-3:2010, perf. Criteria A EFT/burst IEC 61000-4-4:2012, ±1kV, ±2kV, perf. Criteria A surge IEC 61000-4-5:2014, L-N: ±0.5kV, ±1kV, L-E(Ground): ±0.5kV, ±1kV, ±2kV, perf. Criteria A conducted immunity IEC 61000-4-6:2013 voltage dips and interruptions IEC 61000-4-11:2004, Dip: 30% Reduction, Dip >95% Reduction, perf. Criteria A IEC 61000-4-11:2004, >95% Reduction, perf. Criteria B MTBF as per MIL-HDBK-217F at 25°C RoHS yes 400,000 cui.com hours Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VOF-130 │ DESCRIPTION: AC-DC POWER SUPPLY date 11/08/2021 │ page 3 of 7 ENVIRONMENTAL parameter conditions/description min operating temperature see derating curve storage temperature operating humidity non-condensing DERATING CURVES EFFICIENCY CURVES cui.com typ max units -30 70 °C -40 85 °C 93 % Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VOF-130 │ DESCRIPTION: AC-DC POWER SUPPLY date 11/08/2021 │ page 4 of 7 MECHANICAL parameter conditions/description dimensions open frame models: 3.000 x 2.000 x 1.201 [76.2 x 50.8 x 30.5 mm] base plate models: 3.598 x 2.000 x 1.299 [91.4 x 50.8 x 33.0 mm] covered models: 3.598 × 2.520 × 1.358 [91.4 x 64.0 x 34.5 mm] min weight open frame models base plate models covered models 135 170 218 g g g cooling natural convection (no integrated fan), see derating curve 10 CFM 100 130 W W MECHANICAL DRAWING Open-frame units: inch [mm] general tolerance: ±0.02 [±0.5] PIN-OUT PIN Function 1 AC (L) 2 AC (N) 3 -Vo 4 -Vo 5 +Vo 6 +Vo cui.com typ max units inches inches inches Additional Resources: Product Page CUI Inc │ SERIES: VOF-130 │ DESCRIPTION: AC-DC POWER SUPPLY Base plate units: inch [mm] general tolerance: ±0.02 [±0.5] PIN-OUT Function 1 AC (L) 2 AC (N) 3 -Vo 4 -Vo 5 +Vo 6 +Vo 3D Model date 11/08/2021 │ page 5 of 7 MECHANICAL DRAWING (CONTINUED) PIN | cui.com Additional Resources: Product Page CUI Inc │ SERIES: VOF-130 │ DESCRIPTION: AC-DC POWER SUPPLY Covered units: inch [mm] general tolerance: ±0.02 [±0.5] PIN-OUT Function 1 AC (L) 2 AC (N) 3 -Vo 4 -Vo 5 +Vo 6 +Vo 3D Model date 11/08/2021 │ page 6 of 7 MECHANICAL DRAWING (CONTINUED) PIN | cui.com Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: VOF-130 │ DESCRIPTION: AC-DC POWER SUPPLY date 11/08/2021 │ page 7 of 7 REVISION HISTORY rev. 1.0 description date initial release 11/08/2021 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
VOF-130-36-BP 价格&库存

很抱歉,暂时无法提供与“VOF-130-36-BP”相匹配的价格&库存,您可以联系我们找货

免费人工找货
VOF-130-36-BP
    •  国内价格
    • 1+478.69226

    库存:16