Not Recommended for New Designs
This product was manufactured for Maxim by an outside wafer foundry
using a process that is no longer available. It is not recommended for
new designs. The data sheet remains available for existing users.
A Maxim replacement or an industry second-source may be available.
Please see the QuickView data sheet for this part or contact technical
support for assistance.
For further information, contact Maxim’s Applications Tech Support.
19-3001; Rev 1; 10/05
Ultra-Low Offset
Voltage Operational Amplifier
The MAX400 guaranteed maximum 10µV offset error is
the lowest input offset voltage of any commercially available (nonchopper) monolithic amplifier. The MAX400
represents a 2.5 times improvement over the highest
grade OP07 (the OP07A), and a 5 times improvement
over the best commercial temperature range device
(OP07E). The offset voltage drift is guaranteed to be a
maximum of 0.3µV/°C which is also an improvement
over the OP07 family.
For the ultimate in DC performance (5µV maximum
offset voltage and 0.05µV/°C maximum offset voltage
drift) the MAX420 and MAX430 series of ±15V monolithic,
chopper-stabilized amplifiers should be consulted.
Features
♦ Ultra-Low Offset Voltage: 10µV (max)
♦ Ultra-Low Offset Voltage Drift: 0.2µV/°C
♦ Ultra Stable vs. Time: 0.2µV/month
♦ Ultra-Low Noise: 0.35µVP-P
♦ Wide Supply Voltage: ±3V to ±18V
♦ High Common-Mode Input: ±14V
♦ No External Components Required
♦ Fits OP07, AD510, 725, 108A/308A Sockets
Applications
Precision Amplifiers
Ordering Information
PART
TEMP RANGE
PIN-PACKAGE
Thermocouple Amplifiers
MAX400MJA
-55°C to +125°C
8 CERDIP
Low-Level Signal Processing
MAX400MTV
-55°C to +125°C
8 TO-99
Medical Instrumentation
MAX400EJA
-40°C to +85°C
8 CERDIP
Strain Gauge Amplifiers
MAX400ETV
-40°C to +85°C
8 TO-99
MAX400CTV
0°C to +70°C
8 TO-99
MAX400CPA
0°C to +70°C
8 Plastic Dip
MAX400CSA
0°C to +70°C
8 SO
High-Accuracy Data Acquisition
Pin Configuration
Typical Operating Circuit
TOP VIEW
+VS
VOS TRIM
VOS TRIM
8
1
7
V+
MAX400
-IN 2
VOUT
6 VOUT
MAX400
-VS
+IN
3
5
4
V-
N.C.
+VS
LOAD
CELL
TO-99
MAX400
VOS TRIM 1
8
VOS TRIM
-IN 2
7
V+
3
6
VOUT
V- 4
5
N.C.
-VS
MAX400
+IN
LOAD CELL AMPLIFIER
DIP
________________________________________________________________ Maxim Integrated Products
For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at
1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com.
1
MAX400
General Description
MAX400
Ultra-Low Offset
Voltage Operational Amplifier
ABSOLUTE MAXIMUM RATINGS
Total Supply Voltage (V+ to V-) ...........................................±22V
Internal Power Dissipation.................................................500mV
TO-99 (T) (derate at 7.1mW/ above +80°C)
Hermatic Dip (J) (derate 6.7mW/°C above +75°C)
Plastic Dip (P) (derate 5.6mW/°C above +36°C)
Differential Input Voltage .....................................................±30V
Input Voltage (Note 1)..........................................................±22V
Storage Temperature Range .............................-65°C to +150°C
Operating Temperature Range
MAX400M ......................................................-55°C to +125°C
MAX400E .........................................................-40°C to +85°C
MAX400C ............................................................0°C to +70°C
Lead Temperature (soldering, 10s) .................................+300°C
Duration of Output Short Circuit ....................................Indefinite
Junction Temperature (TJ).................................-65°C to +160°C
Note 1: For supply voltages less than ±22V, the absolute maximum input voltage is equal to the supply voltage.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(VS = ±15V, TA = +25°C, unless otherwise noted.)
PARAMETER
Input Offset Voltage
Long-Term Input Offset
Voltage Stability
Input Offset Current
Input Bias Current
Input Noise Voltage
Input Noise-Voltage
Density
SYMBOL
10
VOS/Time
(Note 3)
0.2
IB
eN(P-P)
eN
Input Noise-Current
Density
IN
Input Resistance
Differential Mode
RIN
Input Resistance
Common Mode
RINCM
TYP
MAX
10
15
0.3
2.0
0.3
2.0
±0.7
±2.0
±0.7
±2.0
0.35
fO = 10Hz
10.3
10.3
fO = 100Hz
10.0
10.0
fO = 1000Hz
9.6
9.6
0.1Hz to 10Hz
14
14
fO = 10Hz
0.32
0.32
fO = 100Hz
0.14
0.14
fO = 1000Hz
0.12
0.12
(Note 4)
30
80
20
200
CMRR
VCM = ±13V
Power-Supply Rejection
Ratio
PSRR
VS = ±3V to ±18V
UNITS
µV
µV/
month
0.2
0.35
IVR
AVO
MIN
0.1Hz to 10Hz
Common-Mode
Rejection Ratio
2
MAX
4
IOS
MAX400C/E
TYP
(Note 2)
IN(P-P)
Large-Signal Voltage
Gain
MAX400M
MIN
VOS
Input Noise Current
Input Voltage Range
CONDITIONS
nA
nA
µVP-P
nV/√Hz
pAP-P
pA/√Hz
60
MΩ
200
GΩ
±13
±14
±13
±14
V
114
126
114
126
dB
4
10
4
RL ≥ 2kΩ, VO = ±10V
500
1000
500
1000
RL ≥ 500Ω, VO = ±0.5V,
VS = ±3V (Note 4)
150
400
150
400
_______________________________________________________________________________________
10
µV/V
V/mV
Ultra-Low Offset
Voltage Operational Amplifier
MAX400
ELECTRICAL CHARACTERISTICS (continued)
(VS = ±15V, TA = +25°C, unless otherwise noted.)
PARAMETER
SYMBOL
Output Voltage Swing
VO
CONDITIONS
MAX400M
MIN
TYP
RL ≥ 10kΩ
±12.5
RL ≥ 2kΩ
±12.0
RL ≥ 1kΩ
±10.5
MAX400C/E
MAX
MIN
TYP
±13.0
±12.5
±13.0
±12.8
±12.0
±12.8
±12.0
±10.5
±12.0
MAX
UNITS
V
Slew Rate
SR
RL ≥ 2kΩ
0.3
0.3
V/µS
Closed-Loop Bandwidth
BW
AVCL = +1V
0.6
0.6
MHz
Open-Loop Output
Resistance
RO
VO = 0V, IO = 0
60
60
Ω
Power Consumption
PD
VS = ±15V, no load
75
120
75
120
VS = ±3V, no load
4
6
4
6
Offset Adjustment Range
RP = 20kΩ
±4
±4
mW
mV
Note 2: VOS is measured one minute after application of power.
Note 3: Long-term Input Offset Voltage Stability refers to the average trend line of VOS vs. Time over extended periods after the first
30 days of operation. Excluding the initial hour of operation, changes in VOS during the first 30 operating days are typically
2.5µV – refer to typical performance curves.
Note 4: Guaranteed by design.
ELECTRICAL CHARACTERISTICS
(VS = ±15V, TA = full operating temperature range, unless otherwise noted.)
PARAMETER
SYMBOL
Input Offset Voltage
Average Temperature
Coefficient of Input
Offset Voltage
CONDITIONS
MAX400M
MIN
MAX400C/E
TYP
MAX
MIN
TYP
MAX
UNITS
VOS
(Note 5)
20
40
20
40
µV
TCVOS
(Note 6)
0.2
0.3
0.2
0.3
µV/°C
4.0
0.8
4.0
nA
Input Offset Current
IOS
0.8
Average Input Offset
Current Drift
TCIOS
5
Input Bias Current
IB
±1.0
Average Input Bias
Current Drift
TCIB
8
Input Voltage Range
IVC
Common-Mode
Rejection Ratio
CMRR
VCM = ±13V
Power-Supply Rejection
Ratio
PSRR
VS = ±3V to ±18V
Large-Signal Voltage
Gain
AVO
Output Voltage Swing
VD
RL ≥ 2kΩ, VO = ±10V
RL ≥ 2kΩ
5
±4.0
±1.0
pA/°C
±4.0
nA
8
pA/°C
±13
±13.5
±13
±13.5
V
106
123
106
123
dB
5
20
5
20
µV/V
200
400
200
400
V/mV
±12.0
±12.6
±12.0
±12.6
V
Note 5: Offset Voltage is measured one minute after application of power.
Note 6: 100% tested.
_______________________________________________________________________________________
3
MAX400
Ultra-Low Offset
Voltage Operational Amplifier
V+
100Ω
2
7
20kΩ
1
2
-
100Ω
8
7
INPUT
6
OUTPUT
MAX400
3
+
3.3kΩ
6
V+
OUTPUT
MAX400
3
4.7µF
4
(≈10Hz FILTER)
V2.5MΩ
4
V-
INPUT-REFERRED NOISE =
Figure 1. Optional Offset Nulling Circuit
V0
25,000
Figure 2. Low-Frequency Noise Test Circuit
Typical Operating Characteristics
24
20
16
12
8
1000
RS1 = RS2 = 200kΩ
THERMAL NOISE OF SOURCE
INPUT NOISE VOLTAGE (nV√Hz)
VS = ±15V
TA = +25°C
MAX400 toc01
MAX400 toc02
28
PEAK-TO-PEAK AMPLITUDE (V)
TOTAL INPUT NOISE VOLTAGE
vs. FREQUENCY
LOW-FREQUENCY NOISE
RESISTORS INCLUDED
100
RESISTORS EXCLUDED
RS = 0Ω
10
VS = ±15V
TA = +25°C
4
0
1
1k
10k
100k
FREQUENCY (Hz)
4
MAX400 toc03
MAXIMUM OUTPUT SWING
vs. FREQUENCY
1M
1
10
100
FREQUENCY (Hz)
_______________________________________________________________________________________
1k
Ultra-Low Offset
Voltage Operational Amplifier
PSRR vs. FREQUENCY
100
100
90
90
80
80
70
70
60
60
10
100
1k
10k
1.0
10
100
10k
1k
0.1
1
10
100
1k
10k 100k 1M 10M
FREQUENCY (Hz)
OFFSET VOLTAGE CHANGE
DUE TO THERMAL SHOCK
INPUT BIAS CURRENT
vs. TEMPERATURE
INPUT BIAS CURRENT
vs. DIFFERENTIAL INPUT VOLTAGE
INPUT BIAS CURRENT (nA)
TA = +25°C
TA = +70°C
20
THERMAL SHOCK
RESPONSE BAND
15
10
5
4
VS = ±15V
3
2
1
DEVICE IMMERSED IN
+70°C OIL BATH
0
0
20
40
60
80
100
0
30
NONINVERTING INPUT BIAS CURRENT (mA)
VS = ±15V
MAX400 toc09
FREQUENCY (Hz)
MAX400 toc07
ABSOLUTE CHANGE IN
INPUT OFFSET VOLTAGE (µV)
40
FREQUENCY (Hz)
30
-20
80
-40
0.1
100k
VS = ±15V
TA = +25°C
0
50
1
25
OPEN LOOP GAIN (dB)
110
120
MAX400 toc05
MAX400 toc04
110
MAX400 toc08
CMRR (dB)
120
OPEN-LOOP FREQUENCY RESPONSE
120
MAX400 toc06
CMRR vs. FREQUENCY
130
AT |VDIFF| ≤ 1.0V, |IB| ≤2nA
20
10
0
-10
-20
VS = ±15V
TA = +25°C
-30
-50
TIME (s)
0
50
TEMPERATURE (°C)
100
-30
-20
-10
0
10
20
30
DIFFERENTIAL INPUT VOLTAGE (V)
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are
implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.
Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 _____________________ 5
© 2005 Maxim Integrated Products
Printed USA
is a registered trademark of Maxim Integrated Products, Inc.
MAX400
Typical Operating Characteristics (continued)
很抱歉,暂时无法提供与“MAX400CPA+”相匹配的价格&库存,您可以联系我们找货