37 16.5 17.1
Features
Small size, light weight. Withstands high temperature, operating under 105 Heavy contact load switching current up to 10A. ambient temperature.
Operation condition
Insulation Resistance Dielectric Strength Between contacts Between contact and coil Shock resistance Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass 1000M min (at 500VDC) Item 7 of IEC255-5 Item 6 of IEC255-5 Item 6 of IEC255-5 IEC68-2-27 T Ea est IEC68-2-6 Test Fc IEC68-2-21 Test Ua1 IEC68-2-20 Test Ta method 1 IEC68-2-3Test Ca
50Hz 1000V 50Hz 1000V 100m/s2 11ms 10~40Hz double amplitude 1.27mm 10N 235 2 3 0.5s -40~105 85% (at 20 ) 25g
Patent No.: 95221385.0
Qualification inspection:
Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24.
Ordering Information
Dimensions
4
3 Coil rated voltage(V) DC: 12 4 Coil power consumption 0.64:0.64W 0.93:0.93W
Max. 1.457max. Max. 0.650max. 0.051 Max. 0.673max. 0.236 0.480
mm /inch
NV2R S DC12V 0.64
1 2 3
1 P art number NV2R 2 Enclosure S: Sealed type Z: Dust cover
0.079
Contact Arrangement Contact Material Contact Rating (resistive) Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Operation Electrical life Mechanical
2 1C 2 SPDT(B-M) H-Bridge AgSnO2 AgSnO2In2O3 10A/14VDC 140 W 24VDC Max. Switching Current:10A 50m Item 3.12 of IEC255-7 105 Item 3.30 of IEC255-7 107 Item 3.31 of IEC255-7
0.012
Contact Data
0.012
0.142 0
0.039
0.016
0.079
0.079
0.634
Dimensions
Mounting(Bottom view)
Coil Parameter
Dash numbers Coil voltage VDC Rated
012-640 012-930 12 12
Max.
14.4 14.4
Coil resistance 10%
Pickup voltage VDC(max)
Release voltage VDC(min)
Coil power consumption W
Operate Time ms
Release Time ms Wiring diagram(Bottom view)
225 155
6.8 6.0
1.2 0.9
0.64 10 0.93 5