FL75L20A

FL75L20A

  • 厂商:

    DELTA(台达)

  • 封装:

    -

  • 描述:

    LINE FILTER 75VAC 20A TH

  • 数据手册
  • 价格&库存
FL75L20A 数据手册
FL75R10A Filter Module 75Vdc Input Maximum, 10A Maximum FEATURES RoHS Compliant Small size: 25.4mm x 25.4mm x 12.0mm (1.0” x 1.0” x 0.47”) Industry standard footprint and pin-out Surface mount or through hole pins Optimized for use with high frequency board mounted DC/DC converters Printed-circuit board mountable ISO 9001, TL 9000, ISO 14001, QS 9000, OHSAS 18001 certified manufacturing facility UL/cUL 60950 (US & Canada) Recognized, VDE 0805 (IEC60950) Licensed Delphi Series Filter Module - FL75L07 0~75Vdc input, 7A Current Rating The Delphi series FL75L07 filter module is the latest offering from a world leader in power systems technology and manufacturing – Delta Electronics, Inc. This filter module is designed to reduce the conducted common-mode and differential-mode noise on input or output lines of high-frequency switching power supplies and has a maximum current rating of 7A. It has the industry standard footprint and pin-out. With creative design technology and optimization of component placement, Delphi FL75L07 filter module possesses outstanding electrical and thermal performance, as well as extremely high reliability under highly stressful operating conditions. APPLICATIONS Common-mode and differential-mode filtering of power supply dc input and output line Computer application Communications equipment DATASHEET DS_FL75L07_ 11272006 SPECIFICATIONS GENERAL SPECIFICATIONS Input voltage, operation Input voltage, continuous Operating temperature Storage temperature Size Typical Typical Typical Typical 0~75V 0~100V -40℃ ~ 115℃ -55℃ ~ 125℃ OUTPUT SPECIFICATIONS Common-mode Insertion Loss Differential-mode Insertion Loss 50Ω circuit, 500 kHz (Typ) 50Ω circuit, 500 kHz (Typ) 40dB 70dB (1.0”. x 1.0”x 0.47”). 25.4 x 25.4 x 12.0 mm ELECTRICAL CHARACTERISTICS CURVES Figure 1: Typical common-mode insertion loss in a 50Ω circuit Figure 2: Typical differential-mode insertion loss in a 50 Ω circuit Internal Schematics Figure 3: Internal schematics DS_FL75L07_11272006 2 THERMAL CONSIDERATIONS Thermal management is an important part of the system design. To ensure proper, reliable operation, sufficient cooling of the power module is needed over the entire temperature range of the module. Convection cooling is usually the dominant mode of heat transfer. Hence, the choice of equipment to characterize the thermal performance of the power module is a wind tunnel. THERMAL CURVES Thermal Testing Setup Delta’s filter modules are characterized in heated vertical wind tunnels that simulate the thermal environments encountered in most electronics equipment. This type of equipment commonly uses vertically mounted circuit cards in cabinet racks in which the power modules are mounted. The following figure shows the wind tunnel characterization setup. The filter module is mounted on a test PWB and is vertically positioned within the wind tunnel. The space between the neighboring PWB and the top of the power module is 6.35mm (0.25”). Figure 5: Temperature measurement location The allowed maximum hot spot temperature is defined at 115℃ FL75L07 A (Standard) Output Current vs. Ambient Temperature and Air Velocity @ Vin = 48V (Either Orientation) Output Current (A) 8 7 6 5 Natural Convectio 4 100LFM 3 Thermal Derating 2 200LFM Heat can be removed by increasing airflow over the module. Figure 4 shows maximum output is a function of ambient temperature and airflow rate. To enhance system reliability, the power module should always be operated below the maximum operating temperature. If the temperature exceeds the maximum module temperature, reliability of the unit may be affected. 300LFM 1 0 25 35 45 55 65 75 85 Ambient Temperature (℃) Figure 6: Output Current vs. Ambient Temperature and Air Velocity @ Vin = 48V (Either Orientation) FACING PW B PW B MODULE AIR VELOCITY AND AMBIENT TEMPERATURE MEASURED BELOW THE MODULE AIR FLOW 50.8 (2.0”) 10 (0.4”) Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches) Figure 4: Wind tunnel test setup DS_FL75L07_11272006 3 APPLICATION Note: C2 & C3 can be 0.01μF to 0.1μF. Select the voltage rating to meet input-to-output isolation requirements. C1 should be the recommended value suggested in the power module data sheet. Figure 7. Recommended schematic when used as the input filter to a high-frequency with open-frame dc-to-dc converter Note: Avoid routing signals or planes under the power module or the filter module. Please ensure all connections are low impedance. Figure 8. Recommended layout when used as the input filter to a high-frequency with open-frame dc-to-dc converter DS_FL75L07_11272006 4 APPLICATION (Continued) Note: C2 through C5 can be 0.01μF to 0.1μF. Select the voltage rating to meet input-to-output isolation requirements. C1 should be the recommended value suggested in the power module data sheet. Figure 9. Recommended schematic when used as the input filter to a high-frequency with metal-cased dc-to-dc converter Note: Avoid routing signals or planes under the power module or the filter module. Please ensure all connections are low impedance. Figure10. Recommended layout when used as the input filter to a high-frequency with metal-cased dc-to-dc converter DS_FL75L07_11272006 5 APPLICATION (Continued) Note: : C2 through C5 and C6 through C9 can be 0.01μF to o.1μF. Select the voltage rating to meet input-to-output isolation requirements. C1 should be the recommended value suggested in the power module datasheet. Figure 11. Recommended schematic of filter module with two power modules ( metal -cased ) DS_FL75L07_11272006 6 Figure 12 shows the experimental result obtained by using this filter module, together with the recommended external components shown in Figures 7 and 8. The Q48SB12025NR A module is one of the Delphi series quarter brick 12V, 25A DCDC converters. Measured noise is greatly dependent on layout, grounding, cable orientation, and load characteristics and the variation is possible from various application conditions. Figure 13. Q48SB12025NR A conducted noise with FL75L07A input filter MECHANICAL DRAWING Top View Side View Bottom View Dimensions are in millimeter Tolerances : x.xx ± 0.5 mm (0.02 in), x.xxx ± 0.25 mm (0.010 in) DS_FL75L07_11272006 7 PICK AND PLACE LOCATION SURFACE-MOUNT TAPE & REEL RECOMMENDED PAD PATTERN (SMD) Note: Inside this filter module, the components have no voltage polarity. Hence, the input positive (Vin+) and input negative (Vin-) labels could be swaped for the convenience of layout and matching with power module input connected to the filter module, just remember to swap the output labels accordingly as well. Please refer to Figures 8 and 10 for how it is applied. DS_FL75L07_11272006 8 LEADED (Sn/Pb) PROCESS RECOMMEND TEMP. PROFILE 2nd Ramp-up temp. Peak temp. 1.0~3.0°C /sec. 210~230°C 5sec. Pre-heat temp. 140~180°C 60~120 sec. Cooling down rate
FL75L20A 价格&库存

很抱歉,暂时无法提供与“FL75L20A”相匹配的价格&库存,您可以联系我们找货

免费人工找货