TECHNICAL DATASHEET PMC Panel Mount Power Supply 12 V 150 W 1 Phase / PMC-12V150W1B□ PMC Highlights & Features • Universal AC input range from 85 Vac to 264 Vac without power de-rating • Full Aluminum casing for light weight and corrosion resistant handling • High MTBF > 700,000 hrs. as per Telcordia SR-332 • Overvoltage / Overcurrent / Over Temperature Protections • IP 20 Compliant (for PMC-12V150W1BJ) • Certified according to IEC/EN/UL 62368-1 Safety Standards CB Certified for worldwide use Model Number: PMC-12V150W1B☐ Unit Weight: 0.54 kg (1.19 lb) Dimensions (L x W x H): 178 x 97 x 38 mm (7.01 x 3.82 x 1.50 inch) General Description Delta’s PMC series of panel mount power supply offers a nominal output voltage of 12 V, a wide temperature range from -10°C to +70°C and a highly dependable minimum hold-up time. The state-of-the-art design is made to withstand harsh industrial environments. What makes the product stands out from the crowd is its lightweight full aluminum body design, which can withstand shock and vibration according to IEC60068-2. The PMC series also offers overvoltage and overload protection. Using a wide input voltage range design, it is compatible worldwide. The input also includes DC operating voltage from 125-375 Vdc. Best of all, this excellent design and quality does not come with a big price tag. Model Information PMC Panel Mount Power Supply Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMC-12V150W1BX 85-264 Vac (125-375 Vdc) 12 Vdc 12.50 A Model Numbering PMC 12V 150W 1 B PMC Series Output Voltage Output Power Single Phase With PFC *Options A 1 J L All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2022, Rev. 06) ☐ Connector Type A – Terminal Block J – IP20 Connector* L – Front Face* TECHNICAL DATASHEET PMC Panel Mount Power Supply 12 V 150 W 1 Phase / PMC-12V150W1B□ Specifications Input Ratings / Characteristics Nominal Input Voltage 100-240 Vac Input Voltage Range 85-264 Vac Nominal Input Frequency 50-60 Hz Input Frequency Range 47-63 Hz Nominal DC Input Voltage 125-250 Vdc DC Input Voltage Range* 125-375 Vdc Input Current < 1.7 A @ 115 Vac, < 1.0 A @ 230 Vac Efficiency at 100% Load > 87% @ 115 Vac, > 88% @ 230 Vac Max Power Dissipation 0% load 100% load < 1.00W @ 115Vac, < 0.5W @ 230Vac < 22.4W @ 115Vac, < 20.4W @ 230Vac Max Inrush Current < 60 A @ 115 Vac, < 120 A @ 230 Vac Power Factor > 0.99 @ 115 Vac, > 0.90 @ 230 Vac Leakage Current < 1 mA @ 240 Vac *Fulfills test conditions for DC input. Safety approval for DC input can be obtained upon request. Output Ratings / Characteristics** Nominal Output Voltage 12 Vdc Factory Set Point Tolerance 12 Vdc ± 2% Output Voltage Adjustment Range 11-14 Vdc Output Current 12.50 A (150 W max.) Output Power 150 W Line Regulation < 0.5% (@ 85-264 Vac input, 100% load) Load Regulation < 1.0% (@ 85-264 Vac input, 0-100% load) PARD*** (20MHz) < 100 mVpp Rise Time < 30 ms @ nominal input (100% load) Start-up Time < 2000 ms @ nominal input (100% load) Hold-up Time > 30 ms @ 115 Vac & 230 Vac (100% load) Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 5% @ 85-264Vac input, 0-100% load (Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz) Start-up with Capacitive Loads 8,000 µF Max **For power de-rating from 50°C to 70°C, see power de-rating on page 3. ***PARD is measured with an AC coupling mode, 5cm wires, and in parallel with 0.1μF ceramic capacitor. 2 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2022, Rev. 06) TECHNICAL DATASHEET PMC Panel Mount Power Supply 12 V 150 W 1 Phase / PMC-12V150W1B□ Mechanical Case Cover Dimensions (L x W x H) Aluminium 178 x 97 x 38 mm (7.01 x 3.82 x 1.50 inch) Unit Weight 0.54 kg (1.19 lb) Indicator Green LED Cooling System DC OK Convection Terminal PMC-12V150W1BA PMC-12V150W1BJ M3.5 x 7 Pins (Rated 300 V/15 A) M3.5 x 7 Pins (Rated 300 V/20 A) PMC-12V150W1BL M3.5 x 7 Pins (Rated 300 V/20 A) Wire PMC-12V150W1BA PMC-12V150W1BJ AWG 18-14 AWG 18-12 PMC-12V150W1BL Noise AWG 18-14 Sound Pressure Level (SPL) 50°C de-rate power by 2.5% / °C Operating Humidity 5 to 95% RH (Non-Condensing) Operating Altitude 0 to 5,000 Meters (16,400 ft.) Shock Test Non-Operating IEC60068-2-27, 30 G (300 m/S²) for a duration of 18ms 1 times per direction, 6 times in total Vibration Non-Operating IEC60068-2-6, 10 Hz to 500 Hz @ 30 m/S² (3G peak); 60 min per axis for all X, Y, Z direction Over Voltage Category II Pollution Degree 2 Protections Overvoltage 16V +10%/-5%, SELV output, Hiccup Mode, Non-Latching (Auto-Recovery). Overload / Overcurrent > 115% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery). Over Temperature < 75°C Ambient Temp@ 100% load, Non-Latching (Auto-Recovery). Short Circuit Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed). Internal Fuse at L pin T4AH Protection Against Shock Class I with PE* connection *PE: Primary Earth Reliability Data MTBF > 700,000 hrs. as per Telcordia SR-332 I/P: 115Vac & 230Vac, O/P: 100% load, Ta: 25°C Expected Cap Life Time 10 years (115 Vac & 230 Vac, 50% load @ 40°C) 3 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2022, Rev. 06) TECHNICAL DATASHEET PMC Panel Mount Power Supply 12 V 150 W 1 Phase / PMC-12V150W1B□ Safety Standards / Directives Safety Entry Low Voltage SELV (IEC 60950-1) Electrical Safety SIQ Bauart UL/cUL recognized CB scheme EN 62368-1 UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395) UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) IEC 60950-1, IEC 62368-1 KC K 60950-1 BIS IEC 60950-1 UKCA BS EN 62368-1 CCC GB9254, GB17625.1 and GB4943.1 BIS IS 13252 (Part 1) CE In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091 3.0 KVac UKCA Galvanic Isolation Input to Output Input to Ground 1.5 KVac Output to Ground 0.5 KVac EMC Emissions (CE & RE) CISPR32, EN/BS EN 55032, KN 32 FCC Title 47: Class B, GB9254 Immunity Generic Standards: EN/BS EN 55024, KN 35 Electrostatic Discharge IEC61000-4-2 Level 4 Criteria A1) Air Discharge: 15 kV Contact Discharge: 8 kV Radiated Field IEC61000-4-3 Level 3 Criteria A1) 80 MHz-1 GHz, 10 V/M with 1kHz tone / 80% modulation Electrical Fast Transient / Burst IEC61000-4-4 Level 3 Criteria A1) 2 kV Surge IEC61000-4-5 Level 3 Criteria A1) Common Mode2): 2 kV Differential Mode3): 1 kV Conducted IEC61000-4-6 Level 3 Criteria A1) 150 kHz-80 MHz, 10 Vrms Power Frequency Magnetic Fields IEC61000-4-8 Criteria A1) 10 A/Meter Voltage Dips and Interruptions IEC61000-4-11 100% dip; 1 cycle (20 ms); Self Recoverable Low Energy Pulse Test (Ring Wave) IEC61000-4-12 Level 3 Criteria A1) Common Mode2): 2 kV Differential Mode3): 1 kV Harmonic Current Emission IEC/EN/BS EN 61000-3-2, Class A; GB17625.1 Voltage Fluctuation and Flicker IEC/EN/BS EN 61000-3-3 Voltage Sag Immunity SEMI F47 – 0706 80% of 200 Vac 70% of 200 Vac 50% of 200 Vac 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line) 4 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2022, Rev. 06) 160 Vac, 1000 ms 140 Vac, 500 ms 100 Vac, 200 ms Criteria A1) Criteria A1) Criteria A1) TECHNICAL DATASHEET PMC Panel Mount Power Supply 12 V 150 W 1 Phase / PMC-12V150W1B□ Block Diagram Device Description PMC-12V150W1BA: Terminal Block PMC-12V150W1BJ: IP20 Connector PMC-12V150W1BL: Front Face 1) 2) 3) 5 Input & Output terminal block connector DC Voltage adjustment potentiometer DC OK control LED (Green) All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2022, Rev. 06) TECHNICAL DATASHEET PMC Panel Mount Power Supply 12 V 150 W 1 Phase / PMC-12V150W1B□ Dimensions  PMC-12V150W1BA: Terminal Block L x W x H: 178 x 97 x 38 mm (7.01 x 3.82 x 1.50 inch)  PMC-12V150W1BJ: IP20 Connector L x W x H: 178 x 97 x 38 mm (7.01 x 3.82 x 1.50 inch) 6 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2022, Rev. 06) TECHNICAL DATASHEET PMC Panel Mount Power Supply 12 V 150 W 1 Phase / PMC-12V150W1B□  PMC-12V150W1BL: Front Face L x W x H: 178 x 97 x 38 mm (7.01 x 3.82 x 1.50 inch) Engineering Data Output Load De-rating VS Surrounding Air Temperature Note 1. 2. 3. 4. Fig. 1 7 De-rating for Vertical and Horizontal Mounting Orientation > 50°C de-rate power by 2.5% / °C 5. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. If the output capacity is not reduced when the surrounding air temperature exceeds its specification as defined on Page 3 under “Environment”, the device may run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. In order for the device to function in the manner intended, it is also necessary to keep a safety distance as recommended in the safety instructions while the device is in operation. Depending on the surrounding air temperature and output load delivered by the power supply, the device housing can be very hot! If the device has to be mounted in any other please contact orientation, info@deltapsu.com for more details. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2022, Rev. 06) TECHNICAL DATASHEET PMC Panel Mount Power Supply 12 V 150 W 1 Phase / PMC-12V150W1B□ Output De-rating VS. Input Voltage  No output power de-rating across the entire input voltage range Assembly & Installation Mounting Ⓐ Ⓑ Ⓒ Mounting holes for power supply assembly onto the mounting surface. The power supply shall be mounted on minimum 2 mounting holes using M3 screw minimum 5 mm (0.20 inch) length. This surface belongs to customer’s end system or panel where the power supply is mounted. Connector Side Mounting (Vertical) Base Mounting (Vertical) Fig. 2 • Recommended Mounting Orientations Use flexible cable (stranded or solid) with the following sizes: PMC-12V150W1BA • 8 Side Mounting (Horizontal) PMC-12V150W1BJ PMC-12V150W1BL AWG 18-14 AWG 18-12 AWG 18-14 The torque at the Connector shall not exceed 13 Kgf.cm (11.23 lb.in). The insulation stripping length should not exceed 0.275” or 7mm. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2022, Rev. 06) TECHNICAL DATASHEET PMC Panel Mount Power Supply 12 V 150 W 1 Phase / PMC-12V150W1B□ Installation   Only use M3 screw ≤ 6 mm (0.23 inch) through the base mounting holes. This is to keep a safe distance between the screw and internal components. Recommended mounting tightening torque: 4~8 Kgf.cm (3.47~6.94 lbf.in). Safety Instructions • • • • • • 9 To ensure sufficient convection cooling, always maintain a safety distance of >20mm (0.79 inch) from all ventilated surfaces while the device is in operation. The device is not recommended to be placed on low thermal conductive surface, for example, plastics. Note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning! Do not touch the terminals while power is being supplied. Risk of electric shock. Prevent any foreign metal, particles or conductors to enter the device through the openings during installation. It can cause: Electric shock; Safety Hazard; Fire; Product failure Warning: When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device, remove L and N connections before removing the Earth connection. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2022, Rev. 06) TECHNICAL DATASHEET PMC Panel Mount Power Supply 12 V 150 W 1 Phase / PMC-12V150W1B□ Functions ■ Graph illustrating the Start-up Time, Rise Time, and Hold-up Time Start-up Time The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied. Rise Time The time required for the output voltage to change from 10% to 90% of its final steady state set value. Hold-up Time Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value. Inrush Current Dynamic Response Inrush Current is the first surge current seen on the input side when AC input is applied to the power supply. It is the first pulse captured; see a typical picture for the inrush current as seen in the power supply. The power supply output voltage will remains within ±5% of its steady state value, when subjected to a dynamic load from 0% to 100% of its rated current. 10  50% duty cycle / 5Hz All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2022, Rev. 06) TECHNICAL DATASHEET PMC Panel Mount Power Supply 12 V 150 W 1 Phase / PMC-12V150W1B□ Overload & Overcurrent Protections (Auto-Recovery) Overvoltage Protection (Auto-Recovery) The power supply’s Overload (OLP) and Over current (OCP) Protections will be activated when output current (IO) exceeds its specification as defined on Page 3 under “Protections. In such occurrence, the output voltage (VO) will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into “Hiccup mode” (AutoRecovery). The power supply will recover once the fault condition of the OLP and OCP is removed and IO is back within the specifications. The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under “Protections”. Over Temperature Protection (Auto-Recovery) It is not recommended to prolong the duration of IO when it is less than OLP/OCP point, but greater than 100%, since it may cause damage to the PSU. As mentioned above, the power supply also has Over Temperature Protection (OTP). This is activated when the overload condition persists for an extended duration and the output current is below the overload trigger point but >100% load. In the event of a higher operating condition at 100% load, the power supply will run into OTP when the surrounding air temperature is >75°C. When activated, the output voltage will go into bouncing mode until the operating surrounding temperature drops to 50°C or output capacity is reduced as recommended in the de-rating graph. Short Circuit Protection (Auto-Recovery) The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. 11 All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2022, Rev. 06) TECHNICAL DATASHEET PMC Panel Mount Power Supply 12 V 150 W 1 Phase / PMC-12V150W1B□ Others PFC – Norm EN 61000-3-2 Line Current harmonic Typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor. In industrial environment, complying with EN 61000-3-2 is only necessary under special conditions. Complying to this standard can have some technical drawbacks, such as lower efficiency as well as some commercial aspects such as higher purchasing costs, Frequently, the user does not profit form fulfilling this standard, therefore, it is important to know whether it is mandatory to meet this standard for a specific application. This product conforms to this standard. Attention Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. Manufacturer and Authorized Representatives Information Manufacturer Thailand Delta Electronics (Thailand) PCL. 909 Pattana 1 Rd., Muang, Samutprakarn, 10280 Thailand Taiwan Delta Electronics, Inc. 3 Tungyuan Road, Chungli Industrial Zone, Taoyuan County 32063, Taiwan Authorized Representatives The Netherlands Delta Greentech (Netherlands) B.V. Zandsteen 15, 2132 MZ Hoofddorp, The Netherlands 12 United Kingdom Delta Electronics Europe Limited 1 Redwood Court, Peel Park Campus, East Kilbride, Glasgow, G74 5PF, United Kingdom All parameters are specified at 25°C ambient and AC input unless otherwise indicated. www.DeltaPSU.com (June 2022, Rev. 06)
PMC-12V150W1BL 价格&库存

很抱歉,暂时无法提供与“PMC-12V150W1BL”相匹配的价格&库存,您可以联系我们找货

免费人工找货