0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
LPQ172

LPQ172

  • 厂商:

    EMERSON-NETWORKPOWER

  • 封装:

  • 描述:

    LPQ172 - Active power factor correction - Emerson Network Power

  • 数据手册
  • 价格&库存
LPQ172 数据手册
175 Watts LPQ170 Series Total Power: 110-175 Watts Input Voltage: 85-264 VAC 120-300 VDC # of Outputs: Quad Electrical Specs Input Input range Frequency Inrush current Efficiency EMI filter 85-264 VAC, 120-300 VDC 47-63 Hz 38 A max, cold start @ 25°C 75% typical at full load Meets FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted 0.99 typical 1.0 mA @ 50/60 Hz, 264 VAC input Power factor Safety ground leakage current Special Features • Active power factor correction • IEC EN61000-3-2 compliance • Adjustable outputs on 1, 3 & 4 Remote sense on main output • Single wire current sharing • Power fail and remote inhibit • Built-in EMI filter • Low output ripple • Overvoltage protection • Overload protection • Thermal overload protection • DC power good • 5 V standby output • Adjustable floating 4th output • Optional cover (-C suffix) Output Maximum power 110 W convection (75 W with cover LPQ172) 85 W convection - LPQ173 175 W with 30 CFM forced air (130 W with cover - LPQ172 only) 3.3 - 5.5V on main; -12 - 15V on 3rd output 3.3 - 25 V on 4th output- LPQ172 3.3 - 5.5V on 4th output on LPQ173 20 ms @175 W load at nominal line Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating Tracks outputs 1, 3 & 4; 15 to 35% 5 V @ 200 mA regulated ±5% Adjustment range Hold-up time Overload protection Overvoltage protection Standby output Logic Control AC power failure Remote inhibit Remote sense DC-OK TTL logic signal goes high 100 - 500 msec after V1 output; It goes low at least 4 msec before loss of regulation Requires contact closure to inhibit outputs Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. TTL logic signal goes high after main output is in regulation. It goes low when there is a loss of regulation Environmental Operating temperature: 0° to 50°C ambient Low temperature start -20°C Derate each output at 2.5% per degree from 50° to 70°C (except for -C version) Electromagnetic susceptibility: designed to meet EN61000-4, -2, -3, -4, -5, -6, -8, -11, Level 3 Humidity: Operating; non-condensing 5% to 95% Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational Storage temperature: -40° to 85°C Temperature coefficient: ± .04% per °C Safety VDE UL CB CSA CE NEMKO 0805/EN60950/IEC60950 60950 Certificate and report CSA 60950 Level 3 Mark (LVD) EN 60950/EMKO-TSE 121 MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions Technical Support: (888) 41-ASTEC or (407) 241-2752 Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662 rev 09.20.04 AMERICAS 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 ASIA Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 LPQ170 Series Ordering Information Model Number LPQ172 Output Voltage 5 V (3.3 - 5.5 V) 12 V -12 V (-12 -15 V) ±3.3-25 V 5 V (3.3 - 5.5 V) 12 V -12 V (-12 -15 V) 5 V (3.3 - 5.5 V) Minimum Load 0A 0A 0A 0.5 A* 0A 0A 0A 0A Maximum Load with Convection Cooling 15 A 6A 1.5 A 2A 10 A 6A .2 A 10A Maximum Load with 30 CFM Forced Air 30 A 8A 3A 5A 24 A 8A 3A 24 A Peak Load 32 A 10 A 3.5 A 5.5 A 26 A 10 A 3.5 A 26 A Regulation2 ±2% ±3% ±3% ±3% ±2% ±3% ±3% ±2% Ripple P/P(PARD)3 50 mV 120 mV
LPQ172 价格&库存

很抱歉,暂时无法提供与“LPQ172”相匹配的价格&库存,您可以联系我们找货

免费人工找货