Embedded Power for Business-Critical Continuity
LPS40 Series
40 Watts
Total Power: Input Voltage: # of Outputs: 40 - 55 Watts 85 - 264 VAC 120 - 300 VDC Single
Rev. 7.8.09_4 LPS40 Series of 3
Special Features
• • • • • • • • • • • • Universal input 3” x 5” footprint Less than 1U high Remote sense Terminal block option (-T) Built-in EMI filter Low output ripple Adjustable output Overvoltage protection Overload protection 110 KHz switching frequency LPX40 enclosure kit available
Electrical Specifications
Input
Input range: Frequency: Inrush current: Input current: Efficiency: EMI filter: Safety ground leakage current: 85 - 264 VAC; 120 - 300 VDC 47 - 440 Hz < 18 A peak @ 115 VAC; < 36 A peak @ 230 VAC, cold start @ 25 °C 1 A max. (RMS) @ 115 VAC 70% typical at full load FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 class B conducted < 0.5 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power: Adjustment range: Hold-up time: Overload protection: 40 W for convection; 55 W with 30CFM forced air -5, +10% minimum 20 ms @ 40 W load, 115 VAC nominal line Short circuit protection on all outputs Case overload protected @ 110 -145% above peak rating
Safety
• UL UL60950 E132002 • CSA CSA 22.2-234 Level 3 LR53982C • NEMKO EN 60950/EMKO-TUE P94100375 (74-sec)203 • CB Certificate and report 1119, 1125, 1126, 1127 • CE Mark (LVD)
Overvoltage protection: 5 V output; 5.7 to 6.7 VDC. Other outputs 10% to 25% above nominal output Remote sense: Compensates for 0.5 V lead drop minimum Will operate without remote sense connected Reverse connection protected
Embedded Power for Business-Critical Continuity
Environmental Specifications
Operating temperature: 0° to 50 °C ambient. Derate each output 2.5% per degree from 50° to 70 °C, -20 °C start up. Storage temperature: -40 °C to +85 °C Temperature coefficient: ± 0.4% per °C Electromagnetic Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 susceptibility: Humidity: Vibration: MTBF demonstrated: Operating; non-condensing 5% to 95% RH Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5Hz to 500Hz, operational > 550,000 hours at full load and 25 °C ambient conditions
Rev. 7.8.09_4 LPS40 Series of 3
Ordering Information
Model Number LPS41(-T) LPS42(-T) LPS43(-T) LPS44(-T) LPS45(-T) LPS48(-T) Output Minimum Maximum Load with Voltage Load Convection Cooling 3.3 V 5 V 12 V 15 V 24 V 48 V 0A 0A 0A 0A 0A 0A 8 A 8 A 3.3 A 2.6 A 1.7 A 0.9 A Maximum Load with 30CFM Forced Air 11 A 11 A 4.5 A 3.6 A 2.3 A 1.2 A Peak Load 1 Regulation 2 Ripple P/P (PARD)3 12 A 12 A 5 A 4 A 2.5 A 1.3 A ± 2% ± 2% ± 2% ± 2% ± 2% ± 2% 50 mV 50 mV 120 mV 150mV 240mV 480 mV
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle. 2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. 4. (-T) indicates Terminal Block option for input and output (instead of Molex type)
Power Derating Curve
55W 30 CFM Forced Air Cooling 40W 30W Output Power (Watts) 20W
Natural Convection Cooling
27.5W 20W
10W 0W 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C TA – Ambient Temperature – °C
Embedded Power for Business-Critical Continuity
Mechanical Drawing
0.22" (5.6) M1 GND 4.55" (115.6) 5.00" (127)
Americas
5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698
Rev. 7.8.09_4 LPS40 Series 3 of 3
SK201
M2
_
+
SK 2
3.00" (76.2) 2.55" (64.8) 3 1
Remote Sense Connector Voltage Adj. Pot
Europe (UK)
SK 1
N L
1 2 3 4 5 6
Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355
Asia (HK)
0.15" (4) DIA (4 places)
14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888
For global contact, visit:
www.PowerConversion.com
1.14" (29)
techsupport.embeddedpower @emerson.com
0.197" (5)
While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
Pin Assignments
Connector SK1-1 SK1-3 SK2-1 SK2- 2 SK2- 3 SK2-4 SK2-5 SK2-6 SK201-1 SK201-2 AC Input: LPS41 Line Neutral +3.3V +3.3V +3.3V Common Common Common +Sense -Sense LPS42 Line Neutral +5V +5V +5V Common Common Common +Sense -Sense LPS43 Line Neutral +12V +12V +12V Common Common Common +Sense -Sense LPS44 Line Neutral +15V +15V +15V Common Common Common +Sense -Sense LPS45 Line Neutral +24V +24V +24V Common Common Common +Sense -Sense LPS48 Line Neutral +48V +48V +48V Common Common Common +Sense -Sense
Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2009 Emerson Electric Co.
Mating Connectors
Molex 09-50-8031 (USA) Not required for (-T) option 09-91-0300 (UK) PINS: 08-52-0113 DC Outputs: Molex 09-50-8061 (USA) Not required for (-T) option 09-91-0600 (UK) PINS: 08-52-0113 Remote Molex 22-01-2025 Sense: PINS: 08-52-0123 Emerson Network Power Connector Kit #70-841-006, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±0.02” (±0.5mm) 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 VAC input, 25°C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.5 lbs/0.23kg
很抱歉,暂时无法提供与“LPS45”相匹配的价格&库存,您可以联系我们找货
免费人工找货