0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
NFS110-7604PJ

NFS110-7604PJ

  • 厂商:

    EMERSON-NETWORKPOWER

  • 封装:

  • 描述:

    NFS110-7604PJ - Single & quad output - Emerson Network Power

  • 数据手册
  • 价格&库存
NFS110-7604PJ 数据手册
Embedded Power for Business-Critical Continuity NFS110 Series Single & quad output Rev. 06.30.09_69 NFS110 Series 1 of 5 Total Power: 80 - 110 W Input Voltage: 85 - 264 Vac 120 - 370 Vdc # of Outputs: Single, quad Special Features • 7.0 x 4.25 x 1.8 inch package • Overvoltage and short circuit protection • 110 W with 20 CFM • Adjustable outputs • EN55022, EN55011 conducted emissions level B • UL, VDE and CSA safety approvals • CE mark • Available RoHS compliant • 2 year warranty Electrical Specifications Output Voltage adjustability: +5.1 V o/p on multi’s 5.1 V single output 12 V single output 15 V single output 24 V single output LL to HL, FL All outputs on all units At turn-on All outputs Multi o/p 5.1 V only 5.1 V single output 12 V single output 15 V single output 24 V single output Primary power limited (See Note 13) Burst mode operation 85 - 264 Vac 120 - 370 Vdc 47 - 440 Hz 230 Vac 110 Vac, 50 Hz 230 Vac, 50 Hz 35 A 0.2 mA, max. 0.4 mA, max. 3.0% 3.0% 12 - 14 V 15 - 18 V 24 - 30 V ±0.1% max. 0% ±0.02%/°C 6.25 V ± 0.75 V 6.25 V ± 0.75 V 15.75 V ± 1.0 V 22 V ± 1.5 V 33 V ± 2.5 V Pin max. 160 W Pout min. 110 W 0 A Line regulation: Overshoot/undershoot: Temperature coefficient: Overvoltage protection: Output power limit: Minimum output current: Short circuit protection: Safety • VDE0805/EN60950/ • IEC950/IEC1010 File No. 10401-3336-0213 • Licence No. 4001467 7 • UL1950 File No. E132002 • CSA C22.2 No. 950 File No. LR41062C Input Input voltage range: Input frequency range: Input surge current: Safety ground leakage current: All specifications are typical at nominal input, full load at 25 °C unless otherwise stated Embedded Power for Business-Critical Continuity Rev. 06.30.09_69 NFS110 Series  of 5 EMC Characteristics Conducted emissions: Radiated emissions: ESD air: ESD contact: Surge: Fast transients: Radiated immunity: Conducted immunity: EN55022, FCC part 15 EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 4 EN61000-4-3, level 3 EN61000-4-4, level 3 EN61000-4-5, level 3 EN61000-4-6, level 3 110 Vac @ 80 W 110 Vac @ 110 W 230 Vac @ 80 W 230 Vac @ 100 W Multiple outputs +5.1 V single 12 V and 15 V singles 24 V single Input/output Input/chassis Level B Level A Perf. criteria 1 Perf. criteria 1 Perf. criteria 1 Perf. criteria 1 Perf. criteria 2 Perf. criteria 1 35 ms 17 ms 140 ms 100 ms 70% typical 70% typical 72% typical 75% typical 3000 Vac 1500 Vac General Specifications Hold-up time: Efficiency: Isolation voltage: Approvals and standards: (see note 12) Weight: MTBF (@25 ºC): VDE0805, EN60950, IEC950, IEC1010, UL1950, CSA C22.2 No. 950 Singles Multiple outputs MIL-HDBK-217E 550 g (19.4 oz) 600 g (21.2 oz) 125,000 hours min. Environmental Specifications Thermal performance: (See notes 9, 10) Operating ambient Non-operating 0 °C to 50 °C convection cooled +50 °C to +70 °C, convection cooled 0 °C to +50 °C, 20 CFM forced air +50 °C to +70 °C, 20CFM forced air Relative humidity: Altitude: Vibration: (See Note 11) Non-condensing Operating Non-operating 5 - 500 Hz 0° C to +70 °C -40 °C to +85 °C 80 W Derate 2 W/°C 110 W Derate 2.75 W/°C 5 to 95% RH 10,000 feet max. 40,000 feet max. 2.4 G rms peak Peak, 0 °C to +50 °C, max. 60 seconds 110W Embedded Power for Business-Critical Continuity Rev. 06.30.09_69 NFS110 Series 3 of 5 Ordering Information Output Voltage +5.1 V +12 V –12 V –5 V +5.1 V (IA) +24 V (IB) (6) +12 V –12 V +5.1 V 15 V -15 V -5 V 12 V 15 V 24 V Output Currents Max (1) 8 A 4.5 A 0.5 A 0.5 A 8 A 3.5 A 4.5 A 0.5 A 8 A 4 A 0.5 A 0.5 A 7 A 5 A 3.5 A Peak (2) 20 A 9 A 1.5 A 1.5 A 20 A 4.5 A 9 A 1.5 A 20 A 7.5 A 1.5 A 1.5 A 9 A 7.3 A 4.5 A Fan (3) 10 A 5 A 1 A 1 A 10 A 4.5 A 5 A 1 A 10 A 5 A 1 A 1 A 9 A 7.3 A 4.5 A Ripple (4) 50 mV 120 mV 120 mV 50 mV 50 mV 240 mV 120 mV 120 mV 50 mV 150 mV 150 mV 50 mV 120 mV 150 mV 240 mV Total Regulation (5) ± 2.0% ± 3.0% ± 3.0% ± 3.0% ± 2.0% +10/–5.0% ± 3.0% ± 3.0% ± 2.0% ± 4.0% ± 3.0% ± 3.0% ± 2.0% ± 2.0% ± 2.0% NFS110-7612J (7,8) NFS110-7615J (7,8) NFS110-7624J (7,8) NFS110-7604PJ NFS110-7602PJ (6) Mo�el Nu��ers (13, 14, F) o�el NFS110-7601PJ Notes 1 Convection cooled, 80 W maximum. 2 Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total peak power must not exceed 110 W. 3 Forced air, 20 CFM at 1 atmosphere, 110 W maximum. 4 Figure is peak-to-peak. Output ripple is measured across a 50 MHz bandwidth using a 12 inch twisted pair terminated with a 47 µF capacitor. 5 Total regulation is defined as the static output regulation at 25 °C, including initial tolerance, line voltage within stated limits and output voltages adjusted to their factory settings. 6 To achieve stated regulation on the 24 V output on the NFS110-7602PJ, the following load condition must be true: IA / IB ≤ 5, where: IA = +5.1 V output current, and IB = +24 V output current The +24 V output will maintain ±5.0% regulation under the following additional condition: IA ≤ 5 A. 7 Single output models have floating outputs which may be referenced as either positive or negative. Higher voltage supplies may be adjusted over a wide output voltage range, as long as the total output power does not exceed 80 Watts (natural convection) or 110 Watts (forced air). 8 Power fail detect not available on single output models. 9 Derating curve is application specific for ambient temperatures >50 °C, for optimum reliability no part of the heatsink should exceed 90 ºC and no semiconductor case temperature should exceed 100 ºC. 10 Caution: Allow a minimum of 1 second after disconnecting the power when making thermal measurements. 11 Three orthogonal axes, random vibration, 10 minute test for each axis. 12 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 13 Artesyn Technologies recommends a minimum load of 11 W to achieve the design MTBF. See the derating curve on page 3. 14 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. 15 NOTICE: Some models do not support all options. Please contact your local Emerson Network Power representative or use the on-line model number search tool at http://www.PowerConversion.com to find a suitable alternative. Transient Response NFS110-7601PJ +5.1 V (7.5 A to 10 A) +12 V (2.5 A to 5 A) -12 V (0.5 A to 1 A) -5 V (0.5 A to 1 A) +5.1 V (7.5 A to 10 A) +24 V (1.5 A to 3 A) +12 V (2.5 A to 5 A) -12 V (0.5 A to 1 A) +5.1 V (7.5 A to 10 A) +15 V (2.5 A to 5 A) -15 V (0.5 A to 1 A) -5 V (0.5 A to 1 A) +5.1 V (10 A to 20 A) +12 V (4.5 A to 9 A) +15 V (3.65 A to 7.3 A) +24 V (2.25 A to 4.5 A) 150 mV peak, 1 ms recovery 100 mV peak, 0.5 ms recovery 100 mV peak, 0.5 ms recovery 100 mV peak, 0.5 ms recovery 150 mV peak, 1 ms recovery 300 mV peak, 1 ms recovery 100 mV peak, 0.5 ms recovery 100 mV peak, 0.5 ms recovery 150 mV peak, 1 ms recovery 100 mV peak, 0.5 ms recovery 100 mV peak, 0.5 ms recovery 100 mV peak, 0.5 ms recovery 250 mV peak, 1 ms recovery 360 mV peak, 1 ms recovery 450 mV peak, 1 ms recovery 720 mV peak, 1 ms recovery NFS110-7602PJ NFS110-7604PJ NFS110-7605J NFS110-7612J: NFS110-7615J NFS110-7624J Embedded Power for Business-Critical Continuity Rev. 06.30.09_69 NFS110 Series  of 5 OPTIONAL POWER FAIL DETECT TIMING DIAGRAM AC (J1) mating connector Molex 09-50-3051 or Molex 09-91-0500 mating connector with 2478 or equivalent crimp terminals. AC INPUT 4.75V 5V OUTPUT HIGH PFD SIGNAL LOW 0-0.4 MAX T1 0.475 0.010 (12.07) Power fail detect signal (Note 8) 4.75V DC (J2) mating connector 3.5V MIN T3 T2 Molex 09-50-3131 or Molex 09-91-1300 mating connector with 2478 or equivalent crimp terminals. 50ms ≤ T1 ≤ 200ms T2 will vary with line and load T3 ≥ 3ms Pout: 110W PFD output is an open collector which will sink ≤ 40mA in the low state. DERATING CURVE (See Notes 9, 10) 1.80 (45.72) MAX 1.00 0.005 (25.4) Output Power (Watts) 110W 0.050 0.020 (1.27) 3.35 0.015 (85.09) 1.55 0.005 (39.37) Voltage Adjust Optional Power Fail Detect Circuit (Key = Pin 2) 6-32 UNC (4PL) PIN 1 20 CFM FORCED AIR COOLING 80W J2 4.250 0.020 (107.95) 3.750 0.005 (95.25) T1 T1 NATURAL CONVECTION COOLING 55W 40W Pin 1 PIN 1 L1 J1 C6 F1 0.156 DIA. HOLE (4PL) 11W 0W 0C 11W MINIMUM LOAD REQUIRED AT 230VAC 10C 20C 30C 40C 50C 60C 70C 0.250 0.010 (6.35) 0.250 0.010 (6.35) 5A, 250 VAC 6.50 0.005 (165.1) 7.00 0.020 (177.8) Pin Connections J1 Pin 1 Pin 2 Pin 3 J2 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 Pin 11 Pin 12 Pin 13 -5 V N/C = no connection +5.1 V +5.1 V +5.1 V Return Return Return Return +12 V +12 V PFD -12 V +5.1 V +5.1 V +5.1 V Return Return Return Return +12 V +12 V PFD -12 V +24 V +5.1 V +5.1 V +5.1 V Return Return Return Return +15 V +15 V PFD -15 V -5 V Vout Vout Vout Return Return Return Return Vout Vout N/C N/C N/C -7601PJ AC Ground AC Neutral AC Line -7602 P AC Ground AC Neutral AC Line -7604PJ AC Ground AC Neutral AC Line Singles AC Ground AC Neutral AC Line ALL DIMENSIONS IN INCHES (mm) Mechanical Notes: A Metallic or non-metallic stand-offs (maximum diameter 5.4mm) can be used in all four mounting holes without effecting safety approval. B The ground pad of the mounting hole near J1, allows system grounding through a metal stand-off to the system chassis. C The heat sink is grounded, and allows system grounding by mechanical connection to the system chassis. D The supply must be mechanically supported using the PCB mounting holes and may be additionally supported by the heatsink mounting holes. E It is always advisable to attach the power supply heat sink to another thermal dissipator (such as a chassis or finned heatsink etc). The resulting decrease in heat sink mounted component temperatures will improve power supply lifetime. F A standard L-bracket and cover is available for mounting which contains all screws, connectors and necessary mounting hardware. The kit is available, order part number “NFS110CJ”­­. Removed for Key Embedded Power for Business-Critical Continuity A�ericas Rev. 06.30.09_69 NFS110 Series 5 of 5 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.PowerConversion.co� techsupport.e��e��e�power @e�erson.co� While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. E�erson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing E��e��e� Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection E�ersonNetworkPower.co� Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2009 Emerson Electric Co.
NFS110-7604PJ 价格&库存

很抱歉,暂时无法提供与“NFS110-7604PJ”相匹配的价格&库存,您可以联系我们找货

免费人工找货