NLP110

NLP110

  • 厂商:

    EMERSON-NETWORKPOWER

  • 封装:

  • 描述:

    NLP110 - Provides low voltage outputs - Emerson Network Power

  • 数据手册
  • 价格&库存
NLP110 数据手册
Embedded Power for Business-Critical Continuity NLP110 Series Single and Triple Output Total Power: Input Voltage: # of Outputs: 80-110 Watts 90-264 VAC Single, Triple Rev. 02.10.09_152 NLP110 Series 1 of 4 Special Features • • • • • • • • • • Provides low voltage outputs Compliance to EN61000-3-2 (Power Factor = 0.98) 90 Vac to 264 Vac universal input range UL, CSA and VDE safety approvals and CE-Marked to LVD Overvoltage and short circuit protection VDE0871-B, EN55022-B, EN55011-B conducted noise VDE0871-A, EN55022-A, EN55011-A radiated noise Meets all applicable and relevant immunity standards EN61000-4-2,4,5 and 6 RoHS compliant 2 year warranty Electrical Specifications Input Input range: Frequency: Input surge current: (cold start) Safety ground leakage current: Input current: Universal input (See Note 6) 120 Vac 230 Vac 120 Vac, 60 Hz 230 Vac, 50 Hz 120 Vac @ 80 W 120 Vac @ 110 W 230 Vac @ 80 W 230 Vac @ 110 W UL/IEC127 Main output Auxiliary outputs At turn-on Main output 75% to 100% step at 0.1 A µs Main outputs Cyclic operation Single and multiple 90-264 Vac 47-63 Hz 18 A max. 35 A max. 0.45 mA 0.75 mA 0.9 A rms 1.3 A rms 0.48 A rms 0.7 A rms F3.15A H, 250 Vac ±2.0% ±5.0% 1.0 s, max. 5.0% or 250 mV max. dev., 1 ms max. recovery to 1% ±0.02%/°C 125%, ±10% Continuous See table Input fuse: Output Total regulation: (line and load) Rise time: Transient response: Temperature coefficient: Safety • VDE0805/EN60950/IEC950 File No. 10401-3336-1096 • UL1950 File No. E136005 • CSA C22.2 No. 950 File No. LR41062 • CCC Mark Overvoltage protection: Short circuit protection: Minimum output current: All specifications are typical at nominal input, full load at 25 °C unless otherwise stated. Embedded Power for Business-Critical Continuity EMC Characteristics Conducted emissions: Radiated emissions: EN55022, FCC part 15 Level B Level A Compliant Level 3 Level 3 Level 3 Level 3 Level 3 Level 3 16.7 ms @ 110 W 75% min. 3000 Vac 1500 Vac 283 g (10 oz) MIL-HDBK-217F 220,000 hours min. EN55022, FCC part 15 Harmonic current emission correction: EN61000-3-2 ESD air: EN61000-4-2 ESD contact: Surge: Fast transients: Radiated immunity: Conducted immunity: EN61000-4-2 EN61000-4-5 EN61000-4-4 EN61000-4-3 EN61000-4-6 120 Vac, 60 Hz 120 Vac. 80 W (-9905J) Input/output Input/chassis Rev. 02.10.09_152 NLP110 Series 2 of 4 General Specifications Hold-up time: Efficiency: Isolation voltage: Approvals and standards pending: Weight: MTBF demonstrated: EN60950, VDE0805, IEC950, UL1950, CSA C22.2 No. 950 Environmental Specifications Thermal performance: Operating, ambient (see derating curve) Non-operating 50 °C to 70 °C ambient convection cooled 0 °C to +50 °C, ambient convection cooled 0° C to +50 °C -40 °C to +85 °C Derate to 50% load 80 W 0 °C to +50 °C, ambient, 150 LFM forced air 110 W Peak (0 °C to +50 °C, 60 s) (See Note 3) Relative humidity: Altitude: Vibration (See Note 5): Shock Non-condensing Operating Non-operating 5-500 Hz per MIL-STD-810E 5% to 95% RH 10,000 feet max. 30,000 feet max. 2.4 G rms peak 516.4 Part IV DERATING CURVE Output Power (Watts) 110W 80W 150 LFM FORCED AIR COOLING NATURAL CONVECTION COOLING 55W 40W 0C 10C 20C 30C 40C 50C 60C 70C Embedded Power for Business-Critical Continuity Ordering Information Output Voltage +5 V +12 V +48 V +24 V +5 V (A) +3.3 V (B) +12 V +3.3 V (A) +2.5 V (B) +12 V +12 V (A) +3.3 V (B) -12 V +12 V (A) +5 V (B) -12 V Min (6) 0.5 A 0.3 A 0 A 0.2 A 0.5 A 0.2 A 0 A 0.5 A 0.1 A 0 A 0.2 A 0.5 A 0 A 0.2 A 0.2 A 0 A Max (1) 15 A 6.4 A 1.6 A 3.2 A 13 A 13 A 0.65 A 13 A 13 A 0.65 A 6.5 A 13 A 0.65 A 6.5 A 13 A 0.65 A 150 LFM (2) 22 A 9.2 A 2.3 A 4.6 A 16 A 16 A 1 A 16 A 16 A 1 A 8.5 A 16 A 1 A 8.5 A 16 A 1 A 300 LFM (3) 22 A 9.2 A 2.3 A 4.6 A 18 A 20 A 1 A 20 A 20 A 1 A 8.5 A 20 A 1 A 8.5 A 18 A 1 A Peak (4) 22 A 11.5 A 2.5 A 6.0 A 18 A 20 A 1 A 22 A 22 A 1 A 10 A 22 A 1 A 10 A 22 A 1 A Ripple (5) 50 mV 120 mV 240 mV 240 mV 50 mV 50 mV 120 mV 50 mV 50 mV 120 mV 120 mV 50 mV 120 mV 120 mV 50 mV 120 mV Total Regulation ± 2.0% ± 2.0% ± 2.0% ± 2.0% ± 2.0% ± 2.0% ± 5.0% ± 2.0% ± 2.0% ± 5.0% ± 2.0% ± 2.0% ± 5.0% ± 2.0% ± 2.0% ± 5.0% NLP110-9608J NLP110-9695J NLP110-9694J Model Numbers (7, 14, 15) NLP110-9605J NLP110-9612J NLP110-9617J NLP110-9624J NLP110-9693J Rev. 02.10.09_152 NLP110 Series  of 4 Notes 1 Free air convection. Multiple output units: maximum continuous output power not to exceed 80 W. For -9693J; I3.3 V = 13 A max.; I5.0 V = 13 A max.; I3.3 V + I5.0 V ² 16 A. For -9694J; I3.3 V = 13 A max.; I2.5 V = 13 A max.; I3.3 V + I2.5 V ² 16 A For -9695J; I3.3 V = 13 A max.; I12 V = 6.5 A max.; I3.3 V + I12 V ² 16 A. For -9608J; I5.0 V = 13 A max.; I12 V = 6.5 A max.; I5.0 V + I12 V ² 16 A. Single output units: maximum continuous output power not to exceed; 75 W on -9905J; 76.8 W on -9912J,-9924J, and -9917J. 2 150 LFM forced air cooling from L4 side. Multiple output units: maximum continuous output power not to exceed 105 W. For -9693J; I3.3 V = 16 A max.; I5.0 V = 16 A max.; I3.3 V + I5.0 V ² 20 A. For -9694J; I3.3 V = 16 A max.; I2.5 V = 16 A max.; I3.3 V + I2.5 V ² 20 A For -9695J; I3.3 V = 16 A max.; I12 V = 8.5 A max.; I3.3 V + I12 V ² 20 A. For -9608J; I5.0 V = 16 A max.; I12 V = 8.5 A max.; I5.0 V + I12 V ² 20 A. Single output units: maximum continuous output power not to exceed 110 W for all models. 3 300 LFM forced air cooling from L4 side. Multiple output units: maximum continuous output power not to exceed 110 W. For -9693J; I3.3 V = 20 A max.; I5.0 V = 18 A max.; I3.3 V + I5.0 V ² 22 A. For -9694J; I3.3 V = 20 A max.; I2.5 V = 20 A max.; I3.3 V + I2.5 V ² 22 A For -9695J; I3.3 V = 20 A max.; I12 V = 8.5 A max.; I3.3 V + I12 V ² 22 A. For -9608J; I5.0 V = 20 A max.; I12 V = 8.5 A max.; I5.0 V + I12 V ² 22 A. Single output units: maximum continuous output power not to exceed 110 W for all models. 4 Peak output current lasting less than 30 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total regulation limits. 5 Figure is peak-to-peak for convection power rating. Output noise measurements are made across a 20 MHz bandwidth using a 6’ twisted pair, terminated with a 10 µF electrolytic capacitor and a 0.1 µF ceramic capacitor. 6 Minimum load required for correct start-up and operation on single outputs and on main output of multiple versions. Failure to observe minimum load on main output will not allow the supply to start-up correctly. Some electronic test loads have a large delay time before they start drawing current even though the voltage from the supply is present. During this time delay, there is no load on the output and as a result, the supply cannot startup properly and maintain its correct output voltage. In these instances, a dummy resistive load across the output may be necessary to load the output of the supply until the test load can function correctly and draw the intended minimum load. Minimum load required on auxiliary outputs to maintain regulation. 7 For models NLP110-9608J and NLP110-9695J, the 12 V output is floating. For -12 V output, pin 11 on J2 has to be connected to Return making pin 12 the -12 V output 8 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5 Hz to 500 Hz. 9 For optimum reliability, no part of the heatsink should exceed 110 ˚C, and no semiconductor case temperature should exceed 120 ˚C. 10 CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. 11 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 12 The EMI specifications reference measurements made with the power supply mounted on a grounded metal sheet extending 1 inch beyond each edge, using an unshielded cable. No external filtering required during conducted emissions testing but some applications may require additional filtering to achieve system compliance. A line choke, (ac input cords looped twice through an EMI suppression toroid) was used during radiated emissions testing. Considerable radiated testing in 1U six-sided boxes has shown that units can meet level B in typical systems. Application support is available from the factory to assist with EMI compliance. 13 All models require a minimum mounting stand-off of 6.35 mm (0.25 inches) in the end use product. 14 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. 15 NOTICE: Some models do not support all options. Please contact your local Emerson Network Power representative or use the on-line model number search tool at http://www.PowerConversion.com/products. Embedded Power for Business-Critical Continuity 6.50 (165.10) 6.050 (153.670) 0.23 (5.842) 12 2.550 (64.770) 3.00 (76.20) Americas 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Rev. 02.10.09_152 NLP110 Series 4 of 4 J4 J2 F1 J1 ALL DIMENSIONS IN INCHES (mm) MAXIMUM COMPONENT HEIGHT IS 1.26 (32.00) Europe (UK) ! 1 3 T1 (REF.) J3 J5 2 3 1 2 1 1 1 2 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 0.23 (5.842) Asia (HK) Recommended direction for forced air relative to power supply orientation shown below. 4 1 2 3 4 Optimum. Very good. Good. Not recommended. 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: Input Pin Connections J1 Pin 1 Pin 2 Pin 3 AC Neutral No Connection AC Line V (A) Sense + V (A) Sense Safety Earth Output Pin Connections J2 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 Pin 11 Pin 12 www.PowerConversion.com Single No Connection No Connection No Connection Return Return Return Return V (A) V (A) V (A) No Connection No Connection Triple V (B) V (B) V (B) Return Return Return Return V (A) V (A) V (A) V (C) V (C) Return (7 techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. J3 Pin 1 Pin 2 Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co. J4 Pin 1 J5 Pin 1 Pin 2 V (B) Sense + V (B) Sense - Input and output connectors AC (J1) connector type Molex 26-60-4030 or equivalent. valent. DC (J2) connector type 12 position Molex Spox type 26-48 1125 or equivalent. equivalent. Sense (J3) connector type Molex 22-23-2021 or equivalent. equivalent. Earth (J4) connector type Male 0.250 quick disconnect. ck disconnect. Sense (J5) connector type Leoco 2421P02H000. co 2421P02H000. Mating connectors AC (J1) mating connector type Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp terminals. terminals. DC (J2) mating connector type Molex Spox type 26-03-3121 and contact 08-52-0113. 08-52-0113. Sense (J3) mating connector type Molex 22-01-3027 and contact 08-50-0113. t 08-50-0113. Earth (J4) mating connector type pe Molex 90028. Sense (J5) mating connector type Leoco 2420S020000 and contact 2453TPB00V1. ntact 2453TPB00V1.
NLP110 价格&库存

很抱歉,暂时无法提供与“NLP110”相匹配的价格&库存,您可以联系我们找货

免费人工找货