0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EM4223V4WS11E

EM4223V4WS11E

  • 厂商:

    EMMICRO

  • 封装:

  • 描述:

    EM4223V4WS11E - Read-only UHF Radio Frequency Identification Device - EM Microelectronic - MARIN SA

  • 数据手册
  • 价格&库存
EM4223V4WS11E 数据手册
R EM MICROELECTRONIC - MARIN SA EM4223 Read-only UHF Radio Frequency Identification Device according to ISO IEC 18000-6 Description The EM4223 chip is used in UHF passive read-only transponder applications. The chip derives its operating power from an RF beam transmitted by the reader, which is received and rectified by the chip. It transmits its factory-programmed code back to the reader by varying the amount of energy that is reflected from the chip antenna circuit (passive backscatter modulation). The air interface communication protocol is implemented according to ISO18000-6 type A. The code structure supports the effort of EPCglobal, Inc. as an industry accepted standard. It additionally incorporates the Fast Counting Supertag™ protocol for applications where the fast counting of large tag populations is required. The chip is frequency agile, and can be used in the range of 800 MHz to 2.5GHz for RF propagating field applications. Features Air interface is ISO18000-6 type A compliant Supports EAN•UCC and EPC™ data structures as defined by the Auto-ID center Supports Fast Counting Supertag™ mode 128 bit user memory license plate Group select by means of ‘Application Family Identifier’ (AFI) according to ISO Fast reading of user data during arbitration (no need to first take an inventory) Specific command set for supply chain logistics support. Frequency independent: Typically used at 862 - 870 MHz, 902 - 950 MHz and 2.45 GHz Low voltage operation - down to 1.0 V Low power consumption Cost effective -40 to +85°C operating temperature range Typical Applications Supply chain management (SCM) Tracking and tracing Asset control Licensing Auto-tolling Benefits Numbering scheme according to international standards Operates worldwide according to the local radio regulation Ideal for applications where long range and highspeed item identification is required Key words ISO 18000-6A UHF EPC™ data structure Fast Supertag™ Typical Operating Configuration A+ Connect pad A+ And VSS to a dipole antenna EM4223 VDD VSS Fig. 1 Chip design is a joint development with RFIP Solutions Ltd Copyright © 2004, EM Microelectronic-Marin SA 1 www.emmicroelectronic.com R EM4223 Table of contents READ-ONLY UHF RADIO FREQUENCY IDENTIFICATION DEVICE ACCORDING TO ISO IEC 18000-6.................................................1 0H 9. COMMANDS AND STATES............................ 23 43H Description .................................................................. 1 Typical Applications .................................................... 1 Key words ...................................................................1 Benefits .......................................................................1 1H 2H 3H 4H Commands ............................................................... 23 Tag States................................................................ 23 Tag state storage ..................................................... 24 4H 45H 46H 10. COLLISION ARBITRATION............................ 25 47H TABLE OF CONTENTS .....................................2 5H Absolute Maximum Ratings ........................................ 3 Handling Procedures .................................................. 3 Operating Conditions .................................................. 3 Block Diagram............................................................. 3 Electrical Characteristics............................................. 4 Timing Characteristics ................................................ 4 6H 7H 8H 9H 10H 1H General explanation of the collision arbitration mechanism ............................................................... 25 FST SYSTEMS ........................................................ 25 FST MODE OPTIONS.............................................. 26 Use of the round_size function (ISO & FST modes). 27 Ordering Information ................................................ 29 Versions ................................................................... 29 48H 49H 50H 51H 52H 53H 1. 2. GENERAL DESCRIPTION.................................5 12H FUNCTIONAL DESCRIPTION ...........................5 13H General Command Format ......................................... 6 Supported Command set ............................................ 6 14H 15H 3. BASIC COMMAND FORMATS..........................6 16H Short commands......................................................... 6 Extended commands .................................................. 6 Implied MUTE command (Fast Supertag Mode only) . 7 Command state transitions ....................................... 11 17H 18H 19H 20H 4. 5. GENERAL REPLY FORMAT ...........................14 21H FORWARD LINK ENCODING - READER TO TRANSPONDER ..............................................15 2H Carrier modulation pulses ......................................... 15 Basic time interval – definition of “Tari” ..................... 15 Data coding............................................................... 16 Data Frame format.................................................... 16 Data decoding........................................................... 17 Bits and byte ordering ............................................... 17 Reader to Transponder 5 bit CRC (CRC-5) .............. 17 Command Decoder ................................................... 17 23H 24H 25H 26H 27H 28H 29H 30H 6. RETURN LINK DATA ENCODING TRANSPORTER TO READER ........................18 31H Return link data encoding ......................................... 18 Return link preamble................................................. 19 Cyclic Redundancy Check (CRC) ............................. 19 32H 3H 34H 7. MEMORY ORGANISATION AND CONFIGURATION INFORMATION .................19 35H Memory Map ............................................................. 19 Unambiguous User Data (UUD) & SUID................... 19 AFI ............................................................................ 20 Personality Block ...................................................... 20 36H 37H 38H 39H 8. TRANSPONDER SELECTION OPERATION – INIT_ROUND AND BEGIN_ROUND COMMANDS.....................................................21 40H INIT_ROUND COMMAND SELECTION OPERATION .................................................................................. 21 BEGIN_ROUND COMMAND SELECTION OPERATION ............................................................. 22 41H 42H Copyright © 2005, EM Microelectronic-Marin SA 2 www.emmicroelectronic.com R EM4223 Absolute Maximum Ratings Parameter Supply Voltage VDD – VSS (V) Storage temperature (°C) RMS supply current pad A (mA) Symbol VDD Tstore Min -0.3 -50 Max +3.6 +150 10 Table 1 Handling Procedures This device has built-in protection against high static voltages or electric fields; however, anti-static precautions must be taken as for any other CMOS component. Unless otherwise specified, proper operation can only occur when all terminal voltages are kept within the voltage range. Unused inputs must always be tied to a defined logic voltage level. Stresses above these listed maximum ratings may cause permanent damages to the device. Exposure beyond specified operating conditions may affect device reliability or cause malfunction. Operating Conditions Parameter Supply voltage Operating Temperature Symbol Min VDD 1.0 TA -40 Max 3.5 +85 Unit V °C Table 2 Block Diagram VDD Data ROM 128b AFI ROM 8b PON Limit Ant LOGIC CS VSS OSC VSS Data extractor Fig. 2 Copyright © 2005, EM Microelectronic-Marin SA 3 www.emmicroelectronic.com R EM4223 Electrical Characteristics VDD= 2.0V, TA=+25°C, unless otherwise specified Parameter Symbol Operating voltage VDD – VSS Current consumption IS Power On Reset Rising Vponr Power On Reset Fall Vponf Electrostatic discharge HBM to MIL-STD883 method 3015 Internal oscillator Fosc frequency Input series Impedance Rin @900MHz Cin Modulation depth decoding Conditions VDD-VSS = 1.5 V Min. Vponf Typ. 2.0 1.2 1.0 1.5 0.5 192 Max. 3.5 3.9 Unit V uA V V KV KV KHz Ω pF % Table 3 VDD and VSS pad A+ pad Over full temperature range VDD – VSS < 1V At typical pulse width 320 19 0.620 448 27 % 100 % Timing Characteristics Over full voltage and temperature range, unless otherwise specified Parameter Symbol Conditions Forward Link average (Reader to Transponder) Pulse width Tpw 100% modulation depth Pulse interval Data 0 Tpi0 100% modulation depth Pulse interval Data 1 Tpi1 100% modulation depth Return Link (Transponder to Reader) (note 1) Bit rate accuracy short term (note 2) Bit rate accuracy long term @1.5V Reply to Receive turn-around time Receive to Reply turn-around time Tag Command window Tcw nominal at 25°C as selected by factory programmed Personality Bit During a message transmission of nominal 40kb/s Min. 6 12 24 Typ. 33 10 20 40 40 or 160 +/- 1 +/- 15 2 Depends on Transponders chosen reply slot Opens at the start of the 3rd bit clock period after the end of the last bit transmitted by the Transponder to the reader. Closes in the middle of the 5th bit clock period. 150 Max. 14 28 56 Unit kbps uS uS uS kbps % % Bit times uS Note 1: VDD= 2.0V, TA=+25°C Note 2: VDD = 2.0V Table 4 Copyright © 2005, EM Microelectronic-Marin SA 4 www.emmicroelectronic.com R EM4223 1. GENERAL DESCRIPTION The EM4223 is a monolithic integrated circuit transponder for use in UHF passive backscatter RFID applications. Operating power for the transponder circuit is derived from the illuminating RF field of an RFID Reader by means of an on-chip virtual battery rectifier circuit. A user specified license plate or tag identifier is factory programmed into the transponder by means of laser trimming. This data is communicated to the reader by means of backscatter modulation of the illuminating RF carrier wave. The EM4223 supports both the ISO18000-6 type A and the Fast Supertag™ (FST) Protocols. The EM4223 may be configured to wake-up in either of these modes according to user requirements. Once active, the transponder will automatically respond to either protocol (and eventually switch modes) on receipt of the appropriate commands. All commands received from the Reader will have an immediate effect on the Transponder. In addition, certain commands will have a persistent effect. The possible immediate effects are one or both of the following: A change of State (see Fig. 19) A Data Message sent to the Reader. The possible persistent effects are: Data Messages to the Reader will contain SUID (as described later in this section) or Data Messages to the Reader will contain USER DATA of 128 bits, The Round Size (Number of Slots) over which all of the Transponders in the population will spread their Data Messages to the Reader will be configured. The Transponder will switch between ISO and FST modes of operation (as described below). A sub-population of Transponders will be enabled to send Data Messages to the Reader dependent on either the AFI or on all or a portion of the USER DATA of 128 bits. 5H 2. FUNCTIONAL DESCRIPTION When a Transponder is placed in the RF energising field of a Reader it powers up. When the power supply has reached the correct operating voltage, the Configuration Register is loaded with the contents of the three preprogrammed personality flags. Depending on the state of these wake-up flags, the Transponder will be placed in either ISO 18000-6 Type A (ISO) or Fast Supertag (FST) mode and in one of three states: READY, ACTIVE or ROUND_STANDBY. After this process is complete the Transponder is able to receive commands and to transmit data to the Reader. The Transponder is half-duplex and is thus in either receive mode (default) or transmit mode. When not actively transmitting messages to the Reader on the Return Link, the Transponder will wait for the start of a new command, which will be detected as a quiet period of specific duration, followed by a valid Start Of Frame (SOF) symbol (see Fig. 11). The Transponder requires the quiet period in order to ensure that it does not detect partial transmissions by a reader as a valid command. This can occur if a transponder enters the field of a reader and powers up part through a reader transmission. The received SOF symbol is used to calibrate the command decoder every time a command is received. This calibration is used to establish a pivot to distinguish between subsequent data ‘0’ and data ‘1’ symbols. Each time that a new command is received by the Transponder, the SOF re-calibrates the decode counter thereby compensating for any variation in the Transponder clock frequency due to changes in RF excitation levels or temperature variations. The circuit has been designed to accommodate a Transponder clock frequency variation of +/-40% from nominal. When the Transponder is transmitting the receive circuitry is disabled. 54H The start of a command from the Reader has a special significance if a Transponder is operating in the FST mode and is in the ROUND_ACTIVE state. When the falling edge of the first symbol of a command (SOF) is received by a Transponder in the ROUND_ACTIVE state while in FST mode, it will immediately move to the ROUND_STANDBY state. If a command is successfully received, the Transponder will move back to the ROUND_ACTIVE state. If the Transponder does not receive a valid command it will remain in the ROUND_STANDBY state until a valid command has been received. This enables the Reader to silence all Transponders that have not already started sending their Data Messages to the Reader in compliance with the FST protocol. It is important to note that the Reader does not have to send a full command or indeed even a part of a command, as long as it sends a low going pulse of approximately ½ Tari (Type A Reference Interval Time) duration. An important feature of this transponder is its ability to switch seamlessly between ISO mode and FST mode whatever its “wake up” personality setting, depending only on the mode or characteristics of the controlling reader. A Transponder that “wakes up” in the ISO mode on powerup will switch to the FST mode if it receives a Wake_Up_FST command. Similarly, a Transponder that “wakes up” in the FST mode on power-up will switch to the ISO mode if it receives an INIT-ROUND, INITROUND-ALL or BEGIN-ROUND command. Copyright © 2005, EM Microelectronic-Marin SA 5 www.emmicroelectronic.com R EM4223 Transponders will only transmit Data Messages to the Reader while they are in the ROUND_ACTIVE state. When the CURRENT SLOT NUMBER and the SELECTED SLOT NUMBER values held by the Transponder match, the Transponder transmits its Data Message to the Reader. The Reply message will contain either the SUID (the Integrated Circuit Manufacturer code of 0x16 for MARIN and the lower 32 bits of the 128 bit User Data) or the 128 bit User Data . In situations where different groups of transponders present in the reader field contain data having different owners, a reader may selectively wake up these different groups of transponders by means of the ISO compliant AFI parameter in the Init_Round command or by using the Mask parameter in the Begin_Round command. The Begin_Round command additionally supports selection of groups of transponders based on the user data content according to the EPC™ method. General Command Format All commands are transmitted from the Reader to the Transponder by means of pulse interval encoding as defined in chapter 5: forward link encoding, beginning with an SOF (Start Of Frame) and terminating in an EOF (End Of Frame). Commands are supported in accordance with the ISO 18000-6A specification which divides commands into the categories of MANDATORY, OPTIONAL, CUSTOM and PROPRIETARY. The EM4223 supports all of the ISO 18000-6A MANDATORY commands and 4 of the ISO 18000-6A OPTIONAL commands – Init_Round, Close_Slot, New_Round and Begin_Round. In addition, the EM4223 implements 1 PROPRIETARY command in accordance with the ISO 18000-6A specification – this is the Wake_Up_FST command which uses Op-Code 0x39. Commands are divided into 2 basic types: Short Commands of a fixed 16 bit length and Extended commands which consist of a 16 bit section consistent with the Short Command format followed by a variable length extension containing various parameters and a second CRC of 16 bit length which covers the entire st command, including the 1 11 bits which will already have been covered by the 5 bit CRC and the 5 bit CRC itself. The BEGIN_ROUND command is included for Supply Chain Logistics support. In addition to the above, the Fast Supertag™ commands: WAKE_UP_FST and MUTE are supported for compliance with the FST protocol. MUTE is interpreted as any partially decoded or invalid command as described in section 0. 56H 3. BASIC COMMAND FORMATS There are 7 short commands, 2 extended commands and 1 implied command. Short commands Short commands are a fixed length of 16 bits, which includes a 5 bit CRC. The commands comprise the following fields: Protocol extension – 1 bit. Command Op-code – 6 bits. Parameters – 4 bits (parameters could include flags). CRC – 5 Bits. SOF RFU (1 bit) Command Code (6 bits) Parameters & Flags (4 bits) CRC-5 (5 bits) EOF Fig. 3 General format, Short commands Short commands are used for collision arbitration and other immediate functions. Supported Command set The EM4223 fully supports the four ISO MANDATORY commands: NEXT_SLOT, STANDBY_ROUND, RESET_TO_READY and INIT_ROUND_ALL. The ISO OPTIONAL commands: INIT_ROUND, CLOSE_SLOT, and NEW_ROUND are also supported. Extended commands The EM4223 supports 2 Extended commands (Init_Round and Begin_Round). They comprise a fixed length part of 16 bits, which is identical with the format of the 16 bit Short Commands described above, followed by an 8 bit fixed length parameter in the case of both of the nd Extended commands, followed by a 2 parameter of variable length up to 136 bits and terminated with a 16 bit CRC. The Extended commands comprise the following fields: Protocol extension – 1 bit. Command Op-code – 6 bits. Parameters – 4 bits (parameters could include flags). CRC – 5 Bits. Extension of 8 bits (AFI) in the case of the INIT_ROUND command, or an 8 bit (MASK_LENGTH) parameter followed by a variable length (MASK) parameter in the case of the BEGIN_ROUND command CRC-16 :- 16 Bits (over full message from after the SOF to the last bit before the CRC16 itself). Copyright © 2005, EM Microelectronic-Marin SA 6 www.emmicroelectronic.com R EM4223 SOF RFU (1 bit) Command Code (6 bits) Parameters & Flags (4 bits) CRC-5 (5 bits) 1 Optional Parameter (8 bits) st 2nd Optional Parameter (0-136 bit) CRC-16 16 bits EOF Fig. 4 - General format, Extended commands The 2 Extended commands supported by the EM4223 are used to all selected sub-populations of Tags to be introduced to the Arbitration process. Implied MUTE command (Fast Supertag Mode only) When operating in the Fast Supertag Mode and in the ACTIVE state, the reception of the first low-going pulse of any command causes the EM4223 to move to the ROUND_STANDBY state. This could be any single pulse or the first pulse of the SOF of a valid command. The Transponder will continue to decode the command. A known and valid command causes the Transponder to execute the command and to move to either the ROUND_ACTIVE or the READY state, depending on the command and its parameters (if any). An unknown command or a command having an error will cause the Transponder to remain in the ROUND_STANDBY state. During reception of a command, and until the command has been correctly received, the Transponder will holdoff any attempt to reply until the command has been correctly received and executed. At the end of receiving a command, if it has not been correctly decoded, the Transponder will remain in the ROUND_STANDBY state until moved out of this state by the first correctly received and decoded command. If the Tag is in the Fast Supertag Mode and in the TTF (Tag Talks First) sub-mode (Wake Up Status Flag = X00), the Tag will automatically leave the ROUND_STANDBY state after a timeout period of 2.5 X 176 tag bit periods has elapsed since the last MUTE command (176 bits = maximum Tag Data Message length).This timeout will be reset each time a new implied MUTE command is received. Command Protocol Extension Always = 0 Init-Round OpCode 6 bits 01 Parameter / flags 4 bits SUID 1 bit Round Size 3 bits CRC-5 Extended parameters AFI 8 bits CRC-16 Comments 5 bits 16 bits Next-Slot Always = 0 02 * Signature 4 bits 5 bits Close Slot StandbyRound Always = 0 Always = 0 03 04 * Ignored by EM4223 Ignored by EM4223 5 bits 5 bits SUID = 0 tag responds with the 128 bits of user data. SUID = 1 tag responds with SUID. If AFI field = 00H, all tags respond, else if AFI is other value, only tags with matching AFI respond. Also moves tags already active in FST mode to ISO mode. The signature must match the signature value transmitted by the tag in its last reply to acknowledge the tag’s reply. Advances the CURRENT SLOT COUNTER. Advances the CURRENT SLOT COUNTER. The signature is not used in this implementation because the EM4223 has no select state. The EM4223 will always move to the ROUND_STANDBY state. New-Round Always = 0 Always = 0 Always = 0 05 06 * 0A * SUID 1 bit Round size 3 bits 5 bits 5 bits 5 bits Moves Transponder from current state to READY state. SUID = 0 tag responds with the128 bits of user data. SUID = 1 tag responds with SUID. Also moves tags already active in FST mode to ISO mode. Reset-ToReady Init-RoundAll Ignored by EM4223 SUID Round 1 bit size 3 bits Copyright © 2005, EM Microelectronic-Marin SA 7 www.emmicroelectronic.com R EM4223 BeginRound Always = 0 OB SUID 1 bit Round size 3 bits 5 bits Mask length 8 bits Mask value 0-136 bits 16 bits Tags that match the MASK value of MASK length will move to the ROUND_ACTIVE state from the ROUND_STANDBY or READY states or will remain in the ROUND_ACTIVE state if already there. Tags that do not match the Mask will move to the READY from either ROUND_ACTIVE or ROUND_STANDBY states. SUID = 0 tag responds with the 128 bits of user data. SUID = 1 tag responds with SUID, where the DSFID field is replaced by AFI field. Also moves Transponders already active in FST mode to ISO mode. Wakes tag up in the Fast Supertag™ mode. Also moves tags already active in ISO mode to FST mode. SUID = 0 tag responds with the 128 bits of user data SUID = 1 tag responds with SUID. Implied command in FST mode. When tag receives an SOF it moves to the ROUND_STANDBY state. The tag returns to the active state on receipt of a next-slot or init-round or new-round command, or when a period of 2.5 X 176 tag bit periods has elapsed since the last Mute command (176 bits = maximum message length). Table 5- Supported Commands Mandatory ISO commands op-codes are marked with an * and command titles are in bold type face. Wake-UpFST Always = 0 39 SUID 1 Bit Round size 3 bits 5 bits Mute Low Pulse Copyright © 2005, EM Microelectronic-Marin SA 8 www.emmicroelectronic.com R EM4223 Reader Command INIT_ROUND Transponder Operation in ISO Mode Initialises the start of the arbitration sequence and tells the Transponder over how many slots to randomise the transmit slot selection. Configures the Transponder to transmit the SUID data or the full 128 bit User Data to the Reader dependent on the SUID parameter in the command. Moves the Transponder from the READY to the ROUND_ACTIVE states if the Transponders AFI matches the AFI in the command or if the AFI in the command = 0x00 . If the AFI in the command is non-zero and does not match the AFI in the Tag, causes the Tag to move from the ROUND_ACTIVE to the READY states. Initialises the start of the arbitration sequence and tells the Transponder over how many slots to randomise the transmit slot selection. Configures the transponder to transmit the SUID data where DSFID field is replaced by AFI field, or the full 128 bit User Data to the reader, depending in the SUID parameter in the command. Moves the Transponder from the READY to the ROUND_ACTIVE states if the number of bits of the Transponders User Data specified in the command is identical to the matching data in the command Mask parameter . Initialises the start of the arbitration sequence and tells the Transponder over how many slots to randomise the transmit slot selection. Configures the Transponder to transmit the SUID data or the full 128 bit User Data to the Reader dependent on the SUID parameter in the command. Moves the Transponder from the READY to the ROUND_ACTIVE states. Causes the EM4223 to enter a new Round and to change the number of pseudo-slots over which it randomises its transmissions. Tags in the READY state will ignore this command. Not supported in ISO Mode – causes the Transponder to immediately switch to Fast Supertag™ Mode. Transponder Operation in Fast Supertag™ Mode Not supported in Fast Supertag™ Mode – causes the Transponder to immediately switch to ISO Mode. BEGIN_ROUND Not supported in Fast Supertag™ Mode – causes the Transponder to immediately switch to ISO Mode. INIT_ROUND_ALL Not supported in Fast Supertag™ Mode – causes the Transponder to immediately switch to ISO Mode. NEW_ROUND Causes the EM4223 to change the number of pseudo-slots over which it randomises its transmissions. Tags in the READY state will ignore this command. Initialises the start of the Fast Supertag™ arbitration sequence and tells the Transponder over how many slots to randomise the transmit slot selection. Configures the Transponder to transmit the full 128 bit User Data to the Reader irrespective of the SUID parameter in the command. Moves the Tag from the ROUND_STANDBY to the ROUND_ACTIVE states or from the READY to the ROUND_ACTIVE states if the Mask parameter matches, else moves Tag to the READY state. WAKE_UP_FST Copyright © 2005, EM Microelectronic-Marin SA 9 www.emmicroelectronic.com R EM4223 NEXT_SLOT Acknowledges the successful reception of a Transponder transmission by the Reader when valid ie. when received by a Transponder which has just transmitted, and when the command is received in the timing window and when the Signature matches, causing the Transponder to move from the ROUND_ACTIVE to the QUIET states. Causes a Transponder in the ROUND_STANDBY state to move into the ROUND_ACTIVE state. Causes the Transponder Current Slot Counter to increment by one. Causes the Transponder to automatically start a new Round by resetting its Current Slot Counter and randomly selecting a new Reply Slot when the Current Slot Counter has reached the Round Size Value. CLOSE_SLOT Causes a Transponder in the ROUND_STANDBY state to move into the ROUND_ACTIVE state. Causes the Transponder slot counter to increment by one. Causes the Transponder to automatically start a new Round by resetting its Current Slot Counter and randomly selecting a new Reply Slot when the Current Slot Counter has reached the Round Size Value. STANDBY_ROUND Causes the Transponder to move to the ROUND_STANDBY state, in which the Transponder does not transmit its identity or data. Causes the Transponder to move to the ROUND_STANDBY state, in which the Transponder does not transmit its identity or data. While in the ROUND_STANDBY state, the random number generator for slot number choosing is running so that transponder slots are not synchronized and thus have maximum spread and randomisation in the Transmit times. When the Transponder exits the ROUND_STANDBY state, it will wait until the next internally generated slot time before reenabling its data transmit circuitry. Moves the Transponder from its current state to READY state. The Transponder will move to the ROUND_STANDBY state upon reception of the first low-going pulse of any command. This could be any single pulse or the first pulse of the SOF of a valid command. The Transponder will continue to decode the command and if the pulse turns out to be part of a valid command, the Transponder will move to either the READY or the ROUND_ACTIVE state depending on the actual command and the command parameters. If the WUS bit = 0 the Transponder will automatically leave the ROUND_STANDBY state after a timeout period of 2.5 X 176 tag bit periods has elapsed since the last MUTE command (176 bits = maximum Data Message length).This timeout will be reset each time a new implied MUTE command is received. Table 6– Command Operations Causes a Transponder in the ROUND_STANDBY state to move into the ROUND_ACTIVE state. Acknowledges the successful reception of a Transponder transmission by the Reader when valid ie. when received by a Transponder which has just transmitted, and when the command is received in the timing window and when the Signature matches, causing the Transponder to move from the ROUND_ACTIVE to the QUIET states. Causes a Transponder in the ROUND_STANDBY state to move into the ROUND_ACTIVE state. RESET_TO_READY MUTE – this is not an actual command but is an implied command derived from the first low-going pulse of any command. Moves the Transponder from its current state to READY state. Not used. Copyright © 2005, EM Microelectronic-Marin SA 10 www.emmicroelectronic.com R EM4223 Command state transitions The following tables show the state transitions for each of the commands supported by the EM4223 and should be read in conjunction with Fig. 19. 57H Command : Init_Round (Tag will be in ISO mode after this command) Initial State Ready Criteria AFI in the command = 0 or tags AFI value matches the value in the command. AFI in the command and Tags AFI value AFI value in the command. None AFI in the command = 0 or tags AFI value matches the value in the command. AFI in the command and Tags AFI value AFI value in the command. AFI in the command = 0 or tags AFI value matches the value in the command. AFI in the command and Tags AFI value AFI value in the command. Action Tag chooses a random slot in which it will send its response. Tag’s Current Slot Counter is reset to first slot. None None Tag chooses a new random slot in which it will send its response. Tag’s Current Slot Counter is reset to first slot. None Tag chooses a new random slot in which it will send its response. Tag’s Current Slot Counter is reset to first slot. None New State Round_Active Ready Quiet Round_Active Quiet Round_Active Ready Round_Active Round_Standby Ready Table 7 – Tag state transitions for Init_Round Command : New_Round Initial State Ready Quiet Round_Active None None None None Criteria Action None None Tag chooses a new random slot in which it will send its response. Tag’s Current Slot Counter is reset to first slot. Tag chooses a new random slot in which it will send its response. Tag’s Current Slot Counter is reset to first slot. New State Ready Quiet Round_Active Round_Standby Round_Active Table 8 – Tag state transitions for New_Round Command : Init_Round_All (Tag will be in ISO mode after this command) Initial State Ready None None None None Criteria Action Tag chooses a random slot in which it will send its response. Tag’s Current Slot Counter is reset to first slot. None Tag chooses a new random slot in which it will send its response. Tag’s Current Slot Counter is reset to first slot. Tag chooses a new random slot in which it will send its response. Tag’s Current Slot Counter is reset to first slot. New State Round_Active Quiet Round_Active Quiet Round_Active Round_Standby Round_Active Table 9 – Tag state transitions for Init_Round_All Copyright © 2005, EM Microelectronic-Marin SA 11 www.emmicroelectronic.com R EM4223 Command : Begin_Round (Tag will be in ISO mode after this command) Initial State Ready Criteria Number of bits of the MASK specified by MASK_LENGTH in the command matches the data in the Tag (AFI followed by USER DATA). st If the 1 8 bits of the MASK = 0 they are not compared. Number of bits of the MASK specified by MASK_LENGTH in the command does not match the data in the Tag. None Number of bits of the MASK specified by MASK_LENGTH in the command matches the data in the Tag (AFI followed by USER DATA). st If the 1 8 bits of the MASK = 0 they are not compared. Number of bits of the MASK specified by MASK_LENGTH in the command does not match the data in the Tag. Number of bits of the MASK specified by MASK_LENGTH in the command matches the data in the Tag (AFI followed by USER DATA). st If the 1 8 bits of the MASK = 0 they are not compared. Number of bits of the MASK specified by MASK_LENGTH in the command does not match the data in the Tag. Action Tag chooses a random slot in which it will send its response. Tag’s Current Slot Counter is reset to first slot. None None Tag chooses a new random slot in which it will send its response. Tag’s Current Slot Counter is reset to first slot. None Tag chooses a new random slot in which it will send its response. Tag’s Current Slot Counter is reset to first slot. None New State Round_Active Ready Quiet Round_Active Quiet Round_Active Ready Round_Standby Round_Active Ready Table 10 – Tag state transitions for Begin_Round Command : Wake_Up_FST (Tag will be in FST mode after this command) Initial State Ready None None None None Criteria Action Tag chooses a random slot in which it will send its response. Tag’s Current Slot Counter is reset to first slot. None Tag chooses a new random slot in which it will send its response. Tag’s Current Slot Counter is reset to first slot. Tag chooses a new random slot in which it will send its response. Tag’s Current Slot Counter is reset to first slot. New State Round_Active Quiet Round_Active Quiet Round_Active Round_Standby Round_Active Table 11 – Tag state transitions for Wake_Up_FST Copyright © 2005, EM Microelectronic-Marin SA 12 www.emmicroelectronic.com R EM4223 Command : Next_Slot Initial State Ready Quiet Round_Active Criteria None None Tag has answered in previous slot, AND st Signature matches AND 1 low pulse of Next_Slot command was received in the acknowledgement time window. Tag is in ISO Mode and has NOT answered in previous slot, OR Signature st does not match OR 1 low pulse of Next_Slot command was not received in the acknowledgement time window. Tag is in FST Mode and has NOT answered in previous slot, OR Signature st does not match OR 1 low pulse of Next_Slot command was not received in the acknowledgement time window. ISO Mode FST Mode None None None Action New State Ready Quiet Quiet The tag shall increment its slot counter and send its response if slot counter matches the chosen slot. The tag will automatically increment is Current Slot Counter at internally determined times and send its response if the its Current Slot Counter matches its Selected Slot Register. The tag shall increment its slot counter and send its response if slot counter matches the chosen slot. The tag resumes the FST Arbitration process and will automatically increment is Current Slot Counter at internally determined times and send its response if the its Current Slot Counter matches its Selected Slot Register. Round_Active Round_Active Round_Standby Round_active Round_active Table 12 - Tag state transitions for Next_Slot Command : Close_slot Initial State Ready Quiet Round_Active Criteria None None ISO Mode FST Mode None None The tag shall increment its slot counter and send its response if slot counter matches the chosen slot. The tag will automatically increment is Current Slot Counter at internally determined times and send its response if the its Current Slot Counter matches its Selected Slot Register. The tag shall increment its slot counter and send its response if slot counter matches the chosen slot. The tag resumes the FST Arbitration process and will automatically increment is Current Slot Counter at internally determined times and send its response if the its Current Slot Counter matches its Selected Slot Register. Action New State Ready Quiet Round_Active Round_Active Round_Standby ISO Mode FST Mode Round_active Round_active Table 13 - Tag state transitions for Close_Slot Command : Reset_To_Ready Initial State Ready Quiet Round_Active Round_Standby Criteria None None None None None None None None Action New State Ready Ready Ready Ready Table 14 - Tag state transitions for Reset_To_Ready Copyright © 2005, EM Microelectronic-Marin SA 13 www.emmicroelectronic.com R EM4223 Command : Standby_Round Initial State Ready Quiet Round_Active Round_Standby Criteria None None None None None None None None Action New State Ready Quiet Round_Standby Round_Standby Table 15 – Tag state transitions for Standby_Round 4. GENERAL REPLY FORMAT The Transponder will reply to a successful arbitration sequence by sending a message having the following format: Preamble – see description of the Return Link. Flags – 2 bits (Preset) Parameters as follows: Transponder type – 1 bit (Always = 0) Battery status – 1 bit (Always = 0) Signature – 4 bits (last 4 bits of the clock counter). Data – 136 bits if the SUID bit = 0 as follows: AFI of 8 bits. User Data of 128 bits. Data – 48 bits if the SUID bit = 1 as follows: DSFID of 8 bits. SUID of 40 bits (lower 32 bits of User Data + IC Manufacturer code). CRC – 16 bits Preamble Flags Parameters Data CRC Fig. 5- Transponder Reply, general format Preamble Flags 2 bits Trans. Type Always = 0 Battery Status Always = 0 Signature 4 bits AFI 8 bits USER DATA 128 bits CRC16 16 bits Fig. 6 – Transponder Reply to commands with the SUID flag = 0. The above reply will be received after a successful arbitration sequence that was initiated by the Init-Round, Init-RoundAll, Begin_Round and Wake-Up_FST commands with the SUID flag = 0. Preamble Flags 2 bits Trans. Type Always = 0 Battery Status Always = 0 Signature 4 bits DSFID Always = 0x00 SUID 40 bits CRC 16 16 bits Fig. 7 – Transponder Reply commands with the SUID flag = 1. The above reply will be received after a successful arbitration sequence that was initiated by the Init_Round, Init_Round_All and Wake_Up_FST commands with the SUID flag = 1. Preamble Flags 2 bits Trans. Type Always = 0 Battery Status Always = 0 Signature 4 bits AFI 8 bits SUID 40 bits CRC 16 16 bits Fig. 8 – Transponder Reply to Begin_Round command with the SUID flag = 1. The above reply will be received after a successful arbitration sequence that was initiated by the Begin_Round command with the SUID flag = 1. Copyright © 2005, EM Microelectronic-Marin SA 14 www.emmicroelectronic.com R EM4223 5. FORWARD LINK ENCODING - READER TO TRANSPONDER Commands and data are received from the Reader, encoded by means of Pulse Interval Encoding. The Reader transmits pulses in the form of dips in its carrier wave. The intervals between dips convey information in accordance with the following description. The Transponder responds to transmissions by the Reader as described herein. Carrier modulation pulses The data transmission from the Reader to the Transponder is achieved by modulating the carrier amplitude (ASK). The data coding is performed by generating pulses at variable time intervals. The duration of the interval between two successive pulses carries the data coding information. This is known as Pulse Interval Encoding, (PIE). The Transponder measures the interpulse time on the high to low transitions (falling) edges of the pulse as shown in Fig. 9 58H Basic time interval – definition of “Tari” The time “Tari” specifies the period in microseconds between two falling edges representing the symbol “0”. The word “Tari” is an acronym for “Type A Reference Interval Time” as defined in the ISO18000-6 Type A specification. The period between the two falling edges defining each of the other symbols is based on a multiple of the basic Tari period. The SOF symbol (Start of Frame) consists of 2 periods, the 1st of which is equal to One Tari, while the 2nd period of the SOF symbol is equal to 3 Tari. The first part of the SOF symbol is provided to allow detector circuitry to settle (should this be necessary). The second part of the SOF symbol is used as a Calibration period. The received SOF symbol is used to calibrate the command decoder every time a command is received. This calibration is used to establish a pivot to distinguish between subsequent data ‘0’ and data ‘1’ symbols. The pivot point has a value of 1.5Tari and is derived from the 3Tari interval contained in nd the 2 part of the SOF symbol. The binary data ‘0’ and ‘1’ are extracted from the incoming data stream by comparing the inter-pulse interval with a pivot point. If the interval is less than the pivot, then the binary value is ‘0’ and if it is greater than the pivot then the binary value is ‘1’ (See clause 0). Each time that a new command is received by the Transponder, the SOF re-calibrates the decode counter thereby compensating for any variation in the Transponder clock frequency due to changes in RF excitation levels or temperature variations. The circuit has been designed to accommodate a Transponder clock frequency variation of ±40% from nominal. The basic Tari period as transmitted by the Reader is specified in Table 16 and illustrated in Fig. 9. 59H 60H 61H Tari 20 µs Tolerance ±100 ppm Table 16 - Reference interval timing Tari 100% M Fig. 9 - Inter-pulse mechanism Copyright © 2005, EM Microelectronic-Marin SA 15 www.emmicroelectronic.com R EM4223 Data coding Data transmitted by the Reader to the Tag is encoded in PIE format as described in 0 and 0 above. Four symbols are encoded; ‘0’, ‘1’, SOF and EOF. The Transponder is able to decode symbols having values as shown in Fig. 10 below. 62H 63H 64H Values falling outside of the limits in Table 17 will cause the received data to be rejected and the EM4223 to wait for an unmodulated carrier of EOF duration or greater before being ready to receive a new command. 65H Symbol 0 1 SOF EOF Mean duration 1 Tari 2 Tari 1 Tari followed by 3 Tari 4 Tari Limits Symbol Time interval in "Tari" 1 2 3 4 ½ Tari < ‘0’ ≤ 3/2 Tari 3/2 Tari < ’1’ < 3 Tari Calibration sequence ≥ 4 Tari Table 17 - PIE symbols '0' '1' 'EOF' 'SOF' Fig. 10 - PIE symbols Data Frame format The bits transmitted by the Reader to the Transponder are embedded in a frame as specified in Fig. 11. Before sending the frame, the Reader ensures that it has established an unmodulated carrier for duration of at least Taq (Quiet time) of 300µs. 6H The frame consists of a Start-Of-Frame (SOF), immediately followed by the data bits and terminated by an End-Of-Frame (EOF). After sending the EOF the Reader maintains a steady carrier for sufficient time to allow all Transponders present to be powered so that they may send their Reply. Taq 1Tari 3 Tari B Quiet SOF B B B EOF Fig. 11 - Forward link frame format Command + Data Copyright © 2005, EM Microelectronic-Marin SA 16 www.emmicroelectronic.com R EM4223 Data decoding The binary data ‘0’ and ‘1’ are extracted from the incoming data stream by comparing the inter-pulse interval with a pivot point. The pivot point has a value of 1.5Tari and is derived from the 3Tari interval contained in the 2nd part of the SOF symbol. If the interval is less than the pivot, then the binary value is ‘0’ and if it is greater than the pivot then the binary value is ‘1’. If the Transponder detects an invalid code it discards the frame and waits for an unmodulated carrier of EOF duration. No Error Messages are sent to the Reader. Bits and byte ordering Coding of data into symbols is MSB first. The coding for the 8 bits of hex byte 'B1' is shown in Fig. 12. 67H 1 0 1 1 0 0 0 1 t 0 Ts Fig. 12 - Example of PIE byte encoding for 'B1' Reader to Transponder 5 bit CRC (CRC-5) The CRC-5 is used only for commands from the Reader to the Transponder. All commands have a CRC-5 as the last 5 bits of the first 16 bit part of an Extended command or as the last 5 bits of a Short Command. The CRC-5 is calculated on all the command bits after the SOF up to the end of the Extended Parameters (11 bits in total – see Fig. 3). 68H Reply to the Reader and during the 2 Transponder bit periods following a Reply transmission. In the case of the Next_Slot command the command is interpreted by the Transponder in one of two ways. If a Next_Slot command is received such that the first pulse of the command is received during the active command window of the Transponder, which follows a transmission by the Transponder and this Next_Slot command contains a signature parameter that matches that sent by the Transponder in its last transmission, then the command will be interpreted as an instruction for that Transponder to move to the quiet state Fig. 13 and below show the timing of the Transponder command window. If a Next_Slot command is received at any time other than coincident with an active command window (opened by the Transponder following a transmission) or if the Transponder had not transmitted a Reply immediately prior to receiving the NEXT_SLOT command or if the Next_Slot command does not contain a signature parameter that matches that sent by the Transponder in its last transmission then the command is interpreted as an instruction to step the current slot counter value in ISO mode or as a command to exit the ROUND_STANDBY state in either ISO or FST modes. 69H The polynomial used to calculate the CRC-5 is x^5 + x^3 +1. The CRC-5 register is pre-loaded with '01001' (MSB (C4) to LSB (C0)) prior to commencing a CRC-5 calculation in both the case of a Reader to Transponder command transmission and the case of a Transponder initializing its CRC-5 register prior to receiving a command from the Reader. The 5 bits of the CRC-5 embedded in the command are received MSB first by the Transponder. The Transponder will clock the first 16 bits of an Extended command or a complete Short Command through its CRC-5 register as it is receiving the command from the Reader and if these 16 bits were received without error, the Transponder’s CRC-5 register will contain all zeros after the last bit has been clocked through. Command Decoder The Transponder can receive commands from a Reader at any time other than the time that it is transmitting a Copyright © 2005, EM Microelectronic-Marin SA 17 www.emmicroelectronic.com R EM4223 End of last tag bit Tag bits after last transmitted bit 1 2 3 4 5 6 the last tag data transition occurs at either the centre or end of the last bit period depending on FM0 state. Tag transmission Tag not reflecting Tag listens Tag Command Window 1st high to low transition of the command shall occur in this time. Interrogator RF field carrier steady state level carrier modulated state level Fig. 13 - Command Window Timing 6. RETURN LINK DATA ENCODING - TRANSPORTER TO READER The return link data is modulated onto the impinging illuminating RF carrier using varying impedance modulation. Return link data encoding Data is encoded using Bi-phase space (FM0). FM0 Data Coding MSB first encoding of Byte 10110001 = 'B1' 1 0 1 1 0 0 0 1 Alternative depending on prior conditions t Trlb Fig. 14 - Return link – data encoding Copyright © 2005, EM Microelectronic-Marin SA 18 www.emmicroelectronic.com R EM4223 Return link preamble The FM0 return link preamble has the bit pattern described in Error! Reference source not found. Tag bit periods 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Preamble waveform '1' is tag reflecting, '0' is tag not reflecting Fig. 15 - FM0 Return link preamble Cyclic Redundancy Check (CRC) The 16 bit CRC is calculated on all data bits up to, but not including, the first CRC bit. The polynomial used to calculate the CRC is x^16 + x^12 + x^5 + 1. The 16-bit register is preloaded with 'FFFF’. The resulting CRC value is inverted, attached to the end of the packet and transmitted. The most significant byte shall be transmitted first. The most significant bit of each byte shall be transmitted first. MSByte MSB CRC 16 (8 bits) ↑ first transmitted bit of the CRC LSByte LSB MSB CRC 16 (8 bits) LSB Fig. 16- CRC format 7. MEMORY ORGANISATION AND CONFIGURATION INFORMATION Memory Map The physical memory comprises 128 bits of user memory, 8 bits AFI and 3 personality bits. In addition, the IC Manufacturer Code as specified in ISO7816-6/AM1 is hard-wired into the Transponder. 128 bits UUD memory 8 bit AFI 3 bits Personality Fig. 17- Memory map Unambiguous User Data (UUD) & SUID The user memory on the Transponder comprises 128 bits of user specified data. This data is known as Unambiguous User Data UUD, because it is expected that this data be unique and unambiguous. The UUD is a license plate defined by the user and may be an EPC™, GTAG™ or other user defined number. The Transponder will return a Sub-UID (SUID) as defined in ISO 18000-6 when the SUID flag is =1 in the arbitration initiation commands. The SUID in this Transponder is derived from the least significant 32 bits of the UUD as described below. The SUID consists of 40 bits: the 8 bit manufacturer code followed by the least significant 32 bits of the UUD. Copyright © 2005, EM Microelectronic-Marin SA 19 www.emmicroelectronic.com R EM4223 MSB 128 Upper bits of UUD 40 33 32 LSB 1 Serial number (Lower 32 bits of UUD) MSB 40 33 IC Mfg code “0x16” Hard wired in EM4223. 32 Serial number LSB 1 Fig. 18- UUD/SUID mapping Transponder Unique Identifier (UID) & SUID An ISO 18000-6A Transponder does not transmit the except in response to the optional Get_System_Information command which is supported in the EM4223. All other transactions conducted using the SUID (which is supported). UID ISO not are The Interrogator derives the Transponder 64 bit UID from the SUID and it is made up as follows: Bits 57 64 are always set to Hex ‘E0’. Bits 49 56 carry the Integrated Circuit Manufacturers Code Bits 33 48 are always set to Hex ‘0000’ Bits 1 32 carry the 32 bit Serial number. AFI Application Family Identifier - 8 bits per ISO 18000-6 clause 7.2.3. If the AFI byte is set with all 00 the tag will respond, or if the AFI in the tag matches the AFI byte in the init-round command the tag will respond, otherwise the tag will remain quiet. Personality Block The personality block contains 3 control bits. The default state of these bits is programmed during manufacture. These bits control the Wake Up Status flag (WUS), the power up selection of FST or ISO mode of operation and the Return Link Bit Rate. Transponders will power up in the default mode set by the bits programmed during manufacture. Only the FST/ISO mode flag can be changed by Reader commands. Transponders will be switched to FST mode by the WAKE_UP_FST command. INIT_ROUND, INIT_ROUND_ALL and BEGIN_ROUND commands will switch Transponders to the ISO mode of operation. The state of the WUS bit cannot be changed from the value set during manufacture. Transponders will operate in ISO or MOD_ISO mode depending on the factory programmed state of the WUS bit. Similarly, Transponders will operate as TTF or as RTF in FST mode depending on the factory programmed state of the WUS bit. It is important to note that tags can only switch between MOD_ISO and FST (TTF) or between ISO and FST (RTF) modes. FST/ISO Flag (pbit 1) Wake Up Status Flag (pbit 0) Tag State Power Up Condition READY – Transponder replies in its selected slot in each round. READY - Transponder replies in both the first slot and its selected slot in every round ROUND_STANDBY state, Reader Talks First mode ROUND_ACTIVE –Tag Talks First mode Transponder SUID and Roundsize Initialize Conditions Mode 1 1 0 0 1 0 1 0 Don’t care Don’t care SUID flag = 0 Roundsize = 16 SUID flag = 0 Roundsize = 16 ISO MOD_ISO FST (RTF) FST (TTF) Table18 - Transponder Operational Modes Personality Block 0- Bit 2 determines the Transponder Reply data rate: 0 = 40 kb/s 1 = 160 kb/s Copyright © 2005, EM Microelectronic-Marin SA 20 www.emmicroelectronic.com R EM4223 8. TRANSPONDER SELECTION OPERATION – INIT_ROUND AND BEGIN_ROUND COMMANDS The INIT_ROUND and BEGIN_ROUND commands have the ability to move only a selected sub-set of the Transponder population from the READY to the ROUND_ACTIVE states. Transponders that are already in the ROUND_ACTIVE or ROUND_STANDBY states will be removed from the active Transponder population and moved to the READY state if they do not match the selection parameters sent with the INIT_ROUND or BEGIN_ROUND command. This allows the population to be “thinned”, thus increasing the effective read rate achieved. Because only transponders of interest to the application will be selected any other Transponders in the Reader field will not degrade Reader performance by needing to be read and acknowledge to send them to the QUIET state – they virtually do not exist if they have not been selected. The selection capabilities also allow the Transponder population to be “Tree-Walked” allowing fully “Deterministic” arbitration of a Transponder population. By adding more and more bits to the selection criteria, the population can be resolved down to a single Transponder. (See the explanatory note below). EXPLANATION OF “DETERMINISTIC” OPERATION BASED ON “TREE-WALKING” Transponders that use randomly selected reply slots in order to transmit their data to a Reader have a very small risk of more than one Transponder selecting the same slot several times, which could mean that such tags may not be read before they move out of the active population. This is known as “Probabalistic” operation and must be balanced against the many advantages of this mode of operation. “Tree Walking” is a method of resolving Transponder populations by effectively issuing a series of “tests” or “challenges” in which the Reader would request a response from all tags containing say “0” in the 1st bit position of the Transponder data (or in an encrypted version of the data). If the Reader received a nonclashing response (only 1 transponder responding) it could request that Transponder to send its full data. If the Reader received a clashing response (more than 1 transponder responding) it would know that it had identified a productive “branch” and would extend its test by requesting a response from all tags containing say “00” in the 1st two bit positions of the Transponder data. It would continue testing and requesting responses until it had resolved the entire tag population in this manner. If the Reader received no response it would know that it had identified an unproductive “branch” and would temporarily abandon further testing for Transponders with “0” in the 1st bit position. The Reader would then test for Transponders with “1” in the first bit position. This would continue until all Transponders had been identified, or moved out of the Reader’s RF field. INIT_ROUND COMMAND SELECTION OPERATION (see Fig. 19) The INIT_ROUND command contains a single fixed length (8 bit) selection parameter. This parameter represents the AFI (Application Family Identifier according to ISO18000-6A) value which will be matched with the AFI value contained in the Transponders memory. Transponders with a matching AFI value will move from the ROUND_ACTIVE or ROUND_STANDBY or READY states to the ROUND_ACTIVE state and commence participation in the Arbitration process. Transponders that do not match the AFI value sent in the command will remain in the READY state or they will move to the READY state if they are already in the ROUND_ACTIVE or ROUND_STANDBY states. 70H If the AFI value contained in the INIT_ROUND command is 0x00, the Transponders will ignore the parameter in the command and all Transponders will move to the ROUND_ACTIVE state from the ROUND_ACTIVE or ROUND_STANDBY or READY states. With an AFI parameter of 0x00, the command will perform identically to an INIT_ROUND_ALL command. Tags in the QUIET state will ignore the INIT_ROUND command. Copyright © 2005, EM Microelectronic-Marin SA 21 www.emmicroelectronic.com R EM4223 BEGIN_ROUND COMMAND SELECTION OPERATION (see Fig. 19) The BEGIN_ROUND command contains 2 selection parameters. The 1st parameter, called MASK_LENGTH, consists of a fixed length (8 bit) value, which specifies how many bits will be sent in the following parameter, called the MASK. This MASK_LENGTH will be between 0 and 136 for the EM4223. The MASK value will be compared to the number of bits of the tags data memory specified in the MASK LENGTH parameter. Transponders with data matching the MASK in the command will move from the ROUND_ACTIVE or ROUND_STANDBY or READY states to the ROUND_ACTIVE state and commence participation in the Arbitration process. Transponders whose data does not match the MASK value sent in the command will remain in the READY state or they will move to the READY state if they are already in the ROUND_ACTIVE or ROUND_STANDBY states. 71H The MASK value is transmitted MSB 1st. The 1st bit of the MASK is compared to the MSB of the Transponders AFI, the 2nd bit of the MASK is compared to the 2nd most significant bit of the Transponders AFI and so on, up to the 8th bit of the MASK, which is compared to the AFI. If the 1st 8 bits of the MASK contain the value B00000000, the result of the comparison of the 1st 8 bits of the MASK to the AFI is forced to a Match result. If the MASK_LENGTH is less than 8 bits, then the number of bits of the Transponder’s AFI compared to the MASK is determined by the MASK_LENGTH parameter. The 9th to the 136th bits of the MASK is compared to the 128 bit USER DATA in the Transponder – in other words, bit 9 of the MASK is compared to the MSB of the USER DATA and so on down to bit 136 of the MASK being compared to the LSB of the USER DATA. The number of bits of the USER DATA compared to the MASK is equal to MASK_LENGTH – 8 if MASK_LENGTH > 8. If MASK_LENGTH ≤ 8 no USER DATA bits will be compared to the MASK. Tags in the QUIET state will ignore the BEGIN_ROUND command. Copyright © 2005, EM Microelectronic-Marin SA 22 www.emmicroelectronic.com R EM4223 9. COMMANDS AND STATES Commands The EM4223 supports the commands as specified in Table 5- Supported Commands and as set out in ISO/IEC CD 180006A clause 7.6 and clause 7.7. 72H Tag States FST = 0 & WUS = 1 & RF field on RF FIELD OFF FST = 0 & WUS = 0 & RF field on Quiet Flag set ( power off < 2 secs) Reset_to_ready READY Begin_Round(Match) # Init_Round(Match) # Init_Round_All # Wake_Up_FST @ Reset_To_Ready Begin_Round(Unmatch) # Init_Round(Unmatch) # QUIET Next_Slot (OK) ROUND_ACTIVE Next_Slot (Not OK) Close_Slot New_Round All commands except: Begin_Round(Match) # "Reset_To_Ready" Init_Round(Match) # Init_Round_All # Wake_Up_FST @ 2.5 Message Timeout if FST = 0 & WUS = 0 Next_Slot (Not OK) Close_Slot New_Round End of FST Tag Internal Slot Begin_Round(Match) # Init_Round(Match) # Init_Round_All # Wake_Up_FST @ Standby_Round (Incomplete or Unrecognised Cmnd) & FST=0 Standby_Round Incomplete or Unrecognised Cmnd Reset_To_Ready Begin_Round(Unmatch) # Init_Round(Unmatch) # ROUND_STANDBY Fig. 19– State transition diagram showing commands. Copyright © 2005, EM Microelectronic-Marin SA 23 www.emmicroelectronic.com R EM4223 NOTES: Commands marked with the "#" character will place tags in the "ISO" mode of operation. These are the "Begin_Round", "Init_Round" & "Init_Round_All" commands. The "Wake_Up_FST" command marked with the "@" character will place tags in the "FST" mode of operation. The last Mask selection made in the "ISO" mode will be retained when switching from the "ISO" to the "FST" mode. "Next_Slot(OK)" will only occur when the tag receiving the "Next_Slot" command receives the command in the command window immediately following its transmission to the Reader and if the "Next_Slot" command contained the same SIGNATURE value as sent by the tag to the Reader as part of its transmission. In all other cases the "Next_Slot" command will be accepted as "Next_Slot (Not OK)". Tags will automatically start a new round without a "Begin_Round", "New Round", "Init_Round" or "Init_Round_All" command when they receive a "Next_Slot" or "Close_Slot" command while their internal "Current Slot Counter" indicates the last slot in the current round. This will also apply to tags being moved from the ROUND_STANDBY state to the ROUND_ACTIVE state by a "Next_Slot" or "Close_Slot" command. Tag state storage In the case where the Transponder loses the energizing field for short periods of time (eg. when moving), the Transponder retains its state for at least 300µs. In addition, if the Transponder is in the Quiet state, it retains its Quiet state for at least 2s. Note: Implementation of the Quiet state storage may imply that the Transponder will retain this condition during a time greater than 2s, up to several minutes in low temperature conditions. The Reset_to_Ready command overrides the Quiet state under these circumstances. State RF field off READY Description The Transponder is out of the RF field or the Reader Tx Carrier is switched off. The Transponder is in an RF field, its clock is running and it is waiting for a command. Commands to which responsive None. Wake-Up_FST, Init-Round-All, InitRound, Begin-Round None required, responsive to all commands according to the collision arbitration loop. Standby_Round will move the Transponder to the ROUND_STANDBY state. Next-Slot, Close-Slot, New-round, InitRound, Init-Round-All, Begin-Round, Reset-To-Ready, Wake-Up-FST & Time-Out ROUND_ACTIVE The Transponder steps through the hold-off loop and will transmit if it has reached its turn to transmit ROUND_STANDBY ROUND_ACTIVE state is suspended The Transponder is unresponsive to commands and the hold-off loop has been suspended. It will only respond to a Reset-To-Ready command or will reset when removed from the RF field for an extended period of time typically greater than 2 seconds. QUIET (Persistent Sleep) Reset-To-Ready Table19 - Transponder States Copyright © 2005, EM Microelectronic-Marin SA 24 www.emmicroelectronic.com R EM4223 10. COLLISION ARBITRATION The EM4223 implements the ISO 18000-6 Type A anticollision scheme as described in CD ISO-IEC 18000 part 6 Type A. Additionally, the EM4223 implements the Fast Supertag™ anti-collision protocol. The basic collision arbitration scheme is based on slots. The ISO implementation uses regimented slots that are controlled by the Reader. Fast Supertag™ uses pseudoslots (non-synchronised slots) by virtue of the fact that transmissions are initiated in integer multiples of a slot time. However because Transponder clocks will not be identical and because the Reader does not synchronize slots at the start of each slot, there will be a natural drift and the timing of slots between individual Transponders will diverge. Refer to the state diagram, Fig. 19. 73H 2. 3. The Reader detects a collision between two or more Transponder replies. Collisions may be detected either as contention from the multiple transmissions or by detecting an invalid CRC. After waiting until the channel is clear, the Reader sends a Close_Slot command to increment the Transponder slot counter. The Reader receives a Transponder Reply without error, i.e. with a valid CRC. The Reader sends a Next_slot command synchronized to the Transponder timing window, containing the signature of the Transponder just received. General explanation of the collision arbitration mechanism The collision arbitration uses a mechanism, which allocates Transponder transmissions into rounds and slots. A round consists of a number of slots. A Transponder will only transmit once in a round unless the Transponder is in ISO mode and the WUS bit= 0, in which case the Transponder will reply in the first slot as well as in its chosen slot, or only in the first slot if the first slot was selected as the Reply slot by the Transponder. The time position where it transmits in a round is determined randomly. When Transponders in the ROUND_ACTIVE state that have not transmitted in the current slot receive a Next_slot command or a Close_Slot command, they increment their slot counters by one. When the slot counter equals the slot number previously selected by the Transponder, the Transponder transmits according to the rules above otherwise the Transponder waits for another command. The Reader keeps track of the slot count each time it issues a Next_slot command or Close_Slot command. When the number of slots used equals the round_size issued in the Init_round command, the round has completed and the Reader may issue a round initializing command. (Note: A Reader may issue a round initializing command at any time). Transponders that have not been acknowledged (by a synchronous Next_Slot command with a valid signature) during the current round, will enter a new round on determining the end of the current round or at any time on receiving a round initializing command. The Transponders will select a slot at random and transmit in the new round when the slot counter value and the slot selected are equal. If at any time the Transponder receives a wake_up (FST) command whether in the READY state or in the ISO ROUND_ACTIVE or ROUND_STANDBY states, it will immediately switch to the FST mode of operation. ISO COMPLIANT SYSTEMS Each slot has a duration at least as long as a Transponder transmission or as long as the Reader requires to identify an unproductive (empty) slot and send the CLOSE_SLOT command to the Transponder population. The Reader determines the duration of the slot by closing slots with CLOSE_SLOT or NEXT_SLOT commands in response to successful data replies from Transponders or clashing replies from Transponders or in response to identifying an empty slot. On receiving an Init_round command, Transponders randomly select a slot in which to respond. If a Transponder has selected the first slot it will transmit its Reply. The Transponder includes its four-bit Transponder signature in its Reply. If the Transponder has selected a slot number greater than one, it will retain its slot number and wait for a further command. After the Reader has sent the Init_round command there are three possible outcomes: 1. The Reader does not receive a Reply because either no Transponder has selected slot one or the Reader has not detected a Transponder Reply. The Reader then issues a Close_Slot command because it has not received a Reply. FST SYSTEMS In the absence of an RF field, the Transponders are in the RF_field_off state. When the Transponders enter the energizing field of a Reader, they go through a power on reset sequence. If the FST bit = 0 and the WUS bit = 0, then the Transponder moves to the ROUND_ACTIVE State it is therefore in a Tag Talks First mode and commences a Fast Supertag™ collision arbitration sequence. If the FST bit = 0 and the WUS bit = 1, then the Transponder moves to the ROUND_STANDBY state until it receives a Next_Slot, Close_Slot, New_Round or Wake_up_FST command, at which time it commences a Fast Supertag™ collision arbitration sequence. Copyright © 2005, EM Microelectronic-Marin SA 25 www.emmicroelectronic.com R EM4223 Each slot has a duration at least as long as the duration of a Transponder preamble. The actual duration of the slot is determined by the Transponder and is equal to 16 Transponder bit times. If a Transponder has selected the current slot in which to transmit its reply, the Slot length is increased for that Transponder to the duration of a message length so that the Transponder can send its complete message. In order to prevent other tags (those that have not yet started their replies) from transmitting during the first tag’s reply slot the Reader issues a MUTE command to place the tags into the ROUND_STANDBY state. After the active Transponder has finished transmitting its message, and if the Reader has successfully read the Transponder it issues a Next_Slot command synchronously with the tag’s signature. If the Transponder message was not successfully read then the Reader issues a Close_Slot command, which will cause all the tags currently in the ROUND_STANDBY state to re-enter the ROUND_ACTIVE state. The number of slots in a round, referred to as round size, is determined by the Reader and is signaled to the Transponder in the Wake_Up_FST or New_Round command. In the FST mode the tag elects a default roundsize of 16, which may be overridden by a Reader command, however the FST mode is able to operate without any round initializing command. During the subsequent collision arbitration process the Reader dynamically chooses an optimum round size for the following rounds based on the number of collisions and/or unproductive time in a round. The number of collisions is a function of the number of Transponders in the ROUND_ACTIVE state present in the Reader field and the current round size. The Reader signals a change in round size to Transponders by sending a New_Round command containing the required round size. The Transponder on entering the ROUND_ACTIVE State or on re-entering the ROUND_ACTIVE state having completed a round, selects a pseudo slot at random in which to reply. Pseudo slots are equal to Transponder preamble in duration. If the Transponder has selected the first pseudo slot, it will transmit immediately, if not it will hold off until it has reached the selected pseudo-slot and then transmit. On receiving and recognizing a valid Transponder transmission preamble, the Reader sends a MUTE command (SOF), which tells all Transponders that have not yet started transmitting, to move to the ROUND_STANDBY state. When the Reader receives the Transponder Reply without error, it sends a Next_Slot command containing the signature of the Transponder that it has just received. Transponders in the ROUND_STANDBY state will go through an internal time-out sequence and will return to the ROUND_ACTIVE state after a period equal to 2.5 X 176 tag bit periods has elapsed since the last MUTE command if the WUS bit = 0 (this time-out may be overridden by the Transponder receiving further Standby_Round or MUTE commands from the Reader which keep the Transponder in the ROUND_STANDBY state). The Transponder will move to the ROUND_ACTIVE state before the end of time-out period if it receives a Next_Slot, Close_Slot, New_Round or Wake_Up_FST command. When the Transponder has reached the end of a round, it will self-trigger a new round, randomly select a new slot in which to transmit and it will transmit its identity or data when it reaches the selected slot. The process continues until the Transponder has been successfully read and acknowledged by a valid Next_Slot command or removed from the RF energizing field. If at any time the Transponder receives an Init_Round, Init_Round_All or Begin_Round command whether in the READY, ROUND_ACTIVE or ROUND_STANDBY states, it will immediately switch to the ISO mode of operation. BOTH TYPES – READ ACKNOWLEDGE When a Transponder which has transmitted its data in the current slot, receives a Next_slot command, it: Verifies that the signature in the command matches the signature it sent in its last Reply Verifies that the Next_Slot command has been received within the timing window. If the Transponder has met these acknowledge conditions it enters the Quiet state. Otherwise, it remains in the ROUND_ACTIVE state. A Transponder in the Quiet state can only be returned to the active population by means of a Reset_To_Ready command followed by the appropriate round initializing command or by removing it from the RF energizing field for longer than the persistent sleep time. FST MODE OPTIONS If the FST = 0 set and the WUS = 1, the Transponder will wake up in Tag Talks First mode but muted. The first Next_Slot command will move the Transponder to the ROUND_ACTIVE state and it will enter a round as if it had received a Wake_Up command. If both the WUS = 0 and FST = 0 the Transponder will move directly to the ROUND_ACTIVE state as if it had received a Wake_Up command. Copyright © 2005, EM Microelectronic-Marin SA 26 www.emmicroelectronic.com R EM4223 Use of the round_size function (ISO & FST modes) To optimized the system for the Transponder population size, the Reader is able to send round size commands to the Transponder by way of INIT_ROUND, INIT_ROUND_ALL, BEGIN_ROUND, NEW_ROUND and WAKE_UP_FST commands. The Reader needs to determine the proportion of collisions occurring and the amount of white space occurring and accordingly adjust the round size. As collisions increase proportional to the 74H number of successful reads, the round size should be increased. As the proportion of white space increases in proportion to the number of successful reads the round size should be decreased. The round size is coded in the INIT_ROUND, INIT_ROUND_ALL, BEGIN_ROUND, NEW_ROUND and WAKE_UP_FST commands using 3 bits according to Table20. Value Bit coding MSB LSB Round Size '0' '1' '2' '3' '4' '5' '6' '7' 000 001 010 011 100 101 110 111 1 8 16 32 64 128 256 RFU Table20 - Round size coding Copyright © 2005, EM Microelectronic-Marin SA 27 www.emmicroelectronic.com R EM4223 Pad Location Diagram all dimensions in Microns V DD X=388, Y= 511 EM4223 A X= 0, Y= 0 V SS X=735, Y= 0 X = - 142 Y = - 159 Fig. 20 Chip size is X= 1012 by Y= 830 microns Note: The origin (0,0) is the lower felt coordinate of center pads The lower left corner of the chip shows distances of origin Pin # 1 2 3 Name A+ VSS VDD Position x 200 700 450 Position y 120 120 550 Table 21 - Connection Pad Positioning Position is given in μm from the Seal Ring. SOT 23 package outline Dim A NOTES: D&E do not include mold flash Mold flash or protrusions not to exceed .15mm (.006") Controlling dimension: millimeter A1 B C D E e H L D A A1 e α C L S α Min [mm] 0.787 0.025 0.356 0.086 2.667 1.194 1.778 2.083 0.102 0.432 0° Max [mm] 1.194 0.127 0.559 0.152 3.048 1.398 2.032 2.489 0.305 0.559 8° B EH S Fig. 21 Copyright © 2005, EM Microelectronic-Marin SA 28 www.emmicroelectronic.com R EM4223 SOT 23 pinout Pad A EM4223 VDD Pad VSS Fig. 22 Ordering Information Packaged Device: EM4223 V% SP3B Version "Personality word" Check table below Package SP3B = 3-pin SOT23, in Tape&Reel of 3000 pieces Device in DIE Form: EM4223 V% WS 11 Version "Personality word" Check table below Die form WW = Wafer WS = Sawn Wafer/Frame Thickness 7 = 7 mils (158um) 11 = 11 mils (280um) Bumping " " (blank) = no bump E = with gold bumps Versions (Personality word) Personality word V8 V7 V6 V5 V4 V3 V2 V1 Return link data rate 160 Kbps 160 Kbps 160 Kbps 160 Kbps 40 Kbps 40 Kbps 40 Kbps 40 Kbps FST / ISO Flag Wake Up Status Flag ISO ISO FST FST ISO ISO FST FST ISO_MOD RTF TTF ISO_MOD RTF TTF Table 22 Standard Versions: The versions below are considered standards and should be readily available. For the other delivery form, please contact EM Microelectronic-Marin S.A. Please make sure to give the complete part number when ordering. Part Number EM4223V2SP3B EM4223V3SP3B EM4223V2WS11E EM4223V3WS11E Package/Die Form SOT 23 SOT 23 Die 11 mils Die 11 mils Delivery form/Bumping Tape & reel Tape & reel Sawn on frame / Bump Sawn on frame / Bump Table 23 EM Microelectronic-Marin SA (EM) makes no warranty for the use of its products, other than those expressly contained in the Company's standard warranty which is detailed in EM's General Terms of Sale located on the Company's web site. EM assumes no responsibility for any errors which may appear in this document, reserves the right to change devices or specifications detailed herein at any time without notice, and does not make any commitment to update the information contained herein. No licenses to patents or other intellectual property of EM are granted in connection with the sale of EM products, expressly or by implications. EM's products are not authorized for use as components in life support devices or systems. © EM Microelectronic-Marin SA, 08/05, Rev. C Copyright © 2005, EM Microelectronic-Marin SA 29 www.emmicroelectronic.com
EM4223V4WS11E 价格&库存

很抱歉,暂时无法提供与“EM4223V4WS11E”相匹配的价格&库存,您可以联系我们找货

免费人工找货