B32924C3824K789

B32924C3824K789

  • 厂商:

    EPCOS

  • 封装:

  • 描述:

    B32924C3824K789 - Film Capacitors EMI Suppression Capacitors (MKP) - EPCOS

  • 数据手册
  • 价格&库存
B32924C3824K789 数据手册
Film Capacitors EMI Suppression Capacitors (MKP) Series/Type: Date: B32922*7 ... B32924*7 May 2009 © EPCOS AG 2009. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EMI suppression capacitors (MKP) X2 / 305 V AC B32922*7 ... B32924*7 Typical applications For connection in series with the mains For severe ambient conditions Climatic Max. operating temperature: 105 °C Climatic category (IEC 60068-1): 40/105/56 Construction Dielectric: polypropylene (MKP) Plastic case (UL 94 V-0) Epoxy resin sealing (UL 94 V-0) Dimensional drawing Dimensions in mm Features Very small dimensions Self-healing properties Terminals Parallel wire leads, lead-free tinned Standard lead lengths: 6 1 mm Special lead lengths available on request Marking Manufacturer's logo, lot number, date code, rated capacitance (coded), capacitance tolerance (code letter), rated AC voltage (IEC), series number, sub-class (X2), dielectric code (MKP), climatic category, passive flammability category, approvals. Delivery mode Bulk (untaped) Taped (Ammo pack or reel) For taping details, refer to chapter "Taping and packing" Lead spacing ±0.4 15 ... 27.5 Lead diameter d1 0.8 Type B32922*7 ... B32924*7 Marking examples 15 ≤ ≤ 27.5 mm CR ≤ 1 µF 22.5 ≤ ≤ 27.5 mm CR > 1 µF Please read Cautions and warnings and Important notes at the end of this document. Page 2 of 17 B32922*7 ... B32924*7 X2 / 305 V AC Approvals Approval marks Standards EN 60384-14 / IEC 60384-14 UL 1414 / UL 1283 Certificate 40010694 E97863 / E157153 CSA C22.2 No. 1 / CSA C22.2 No. 8 E97863 / E157153 Overview of available types Lead spacing 15 mm Type CR (µF) 0.10 0.15 0.22 0.33 0.47 0.56 0.68 0.82 1.0 1.5 2.2 B32922*7 22.5 mm B32923*7 27.5 mm B32924*7 Please read Cautions and warnings and Important notes at the end of this document. Page 3 of 17 B32922*7 ... B32924*7 X2 / 305 V AC Ordering codes and packing units Lead spacing CR mm 15 µF 0.10 0.15 0.22 0.33 0.33 0.47 0.56 0.33 0.33 0.47 0.56 0.68 0.82 1.0 1.5 0.68 0.82 1.0 1.5 2.2 Max. dimensions w×h×l mm 5.0 × 10.5 × 18.0 6.0 × 12.0 × 18.0 7.0 × 12.5 × 18.0 8.0 × 14.0 × 18.0 8.5 × 14.5 × 18.0 9.0 × 17.5 × 18.0 11.0 × 18.5 × 18.0 6.0 × 15.0 × 26.5 7.0 × 16.0 × 26.5 8.5 × 16.5 × 26.5 8.5 × 16.5 × 26.5 10.5 × 16.5 × 26.5 10.5 × 18.5 × 26.5 11.0 × 20.5 × 26.5 12.0 × 22.0 × 26.5 11.0 × 19.0 × 31.5 11.0 × 19.0 × 31.5 11.0 × 19.0 × 31.5 12.5 × 21.5 × 31.5 14.0 × 24.5 × 31.5 Ordering code (composition see below) B32922C3104+7** B32922C3154+7** B32922C3224+7** B32922C3334M7** B32922D3334+7** B32922C3474+7** B32922C3564+7** B32923C3334M7** B32923D3334+7** B32923C3474+7** B32923C3564+7** B32923C3684+7** B32923C3824+7** B32923C3105+7** B32923C3155M7** B32924C3684+7** B32924C3824+7** B32924C3105+7** B32924C3155+7** B32924C3225+7** Ammo pack pcs./MOQ 4680 3840 3320 2920 2720 2560 2720 2320 1920 1920 1560 1560 1480 Reel Untaped pcs./MOQ pcs./MOQ 5200 4400 3600 3000 2800 2800 2200 2800 2400 2000 2000 1600 1600 1400 1400 1400 1400 1200 4000 4000 4000 2000 2000 2000 1000 2880 2520 2040 2040 2160 2160 2040 1800 1280 1280 1280 1120 1040 22.5 27.5 MOQ = Minimum Order Quantity, consisting of 4 packing units. Further intermediate capacitance values on request. Composition of ordering code + = Capacitance tolerance code: M = ±20% K = ±10% ** = Packaging code: 83 = Untaped (lead length 3.2 ±0.3 mm) 84 = Untaped (lead length 4.0 ±0.3 mm) 86 = Untaped (lead length 5.5 ±0.5 mm) 87 = Untaped (lead length 26 ±2.0 mm) 88 = Reel 89 = Ammo pack Please read Cautions and warnings and Important notes at the end of this document. Page 4 of 17 B32922*7 ... B32924*7 X2 / 305 V AC Technical data Max. operating temperature Top,max Dissipation factor tan δ (in 10-3) at 20 °C (upper limit values) Insulation resistance Rins or time constant τ = CR Rins at 100 V DC, 20 °C, rel. humidity ≤ 65% and for 60 s (minimum as-delivered values) DC test voltage Passive flammability category to IEC 40 (CO) 752 Capacitance tolerances (measured at 1 kHz) Rated AC voltage ( IEC 60384-14 ) Maximum continuous DC voltage VDC Operating voltage Vop at high temperature Damp heat test +105 °C CR ≤ 0.1 µF 0.1 µF < CR ≤ 2.2 µF at 1 kHz 1.0 100 kHz 5.0 1.0 CR > 0.33 µF 30 000 s CR ≤ 0.33 µF 100 000 MΩ 2000 V, 2 s B ±10% (K), ±20% (M) 305 V (50/60 Hz) 630 V TA ≤ 105 °C Vop = 1.25 VAC (1000 h) Test conditions 1. Temperature: +40 °C ±2 °C Relative humidity (RH): 93% ±2% Test duration: 1000 hours or 2. Temperature: Relative humidity (RH): Test duration: Voltage value: or +85 °C ±2 °C 85% ±2% 200 hours 240 V AC, 50 Hz Limit values after damp heat test 3. Temperature: +40 °C ±2 °C Relative humidity (RH): 93% ±2% Test duration: 500 hours Voltage value: 240 V AC, 50 Hz Capacitance change (∆C/C): ≤ 10% Dissipation factor change (∆tan δ): ≤ 0.5 10-3 (at 1 kHz) ≤ 1.0 10-3 (at 10 kHz) Insulation resistance Rins ≥ 50% of minimum or time constant τ = CR Rins: as-delivered values Please read Cautions and warnings and Important notes at the end of this document. Page 5 of 17 B32922*7 ... B32924*7 X2 / 305 V AC Pulse handling capability "dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal voltages, expressed in V/µs. "k0" represents the maximum permissible pulse characteristic of the waveform applied to the capacitor, expressed in V2/µs. Note: The values of dV/dt and k0 provided below must not be exceeded in order to avoid damaging the capacitor. dV/dt and k0 values Lead spacing dV/dt in V/µs k0 in V2/µs 15 mm 340 292 400 22.5 mm 170 146 200 27.5 mm 120 103 200 Please read Cautions and warnings and Important notes at the end of this document. Page 6 of 17 B32922*7 ... B32924*7 X2 / 305 V AC Mounting guidelines 1 1.1 Soldering Solderability of leads The solderability of terminal leads is tested to IEC 60068-2-20, test Ta, method 1. Before a solderability test is carried out, terminals are subjected to accelerated ageing (to IEC 60068-2-2, test Ba: 4 h exposure to dry heat at 155 °C). Since the ageing temperature is far higher than the upper category temperature of the capacitors, the terminal wires should be cut off from the capacitor before the ageing procedure to prevent the solderability being impaired by the products of any capacitor decomposition that might occur. Solder bath temperature Soldering time Immersion depth Evaluation criteria: Visual inspection 1.2 235 ±5 °C 2.0 ±0.5 s 2.0 +0/ 0.5 mm from capacitor body or seating plane Wetting of wire surface by new solder ≥90%, free-flowing solder Resistance to soldering heat Resistance to soldering heat is tested to IEC 60068-2-20, test Tb, method 1A. Conditions: Series Solder bath temperature Soldering time 10 ±1 s MKT boxed (except 2.5 × 6.5 × 7.2 mm) 260 ±5 °C coated uncoated (lead spacing > 10 mm) MFP MKP (lead spacing > 7.5 mm) MKT boxed (case 2.5 × 6.5 × 7.2 mm) MKP (lead spacing ≤ 7.5 mm) MKT uncoated (lead spacing ≤ 10 mm) insulated (B32559) 5 ±1 s
B32924C3824K789 价格&库存

很抱歉,暂时无法提供与“B32924C3824K789”相匹配的价格&库存,您可以联系我们找货

免费人工找货