Aluminum electrolytic capacitors
Single-ended capacitors
Series/Type: Date:
B41858 November 2008
© EPCOS AG 2008. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.
Single-ended capacitors Low impedance 105 °C
B41858
Long-life grade capacitors for professional applications Applications For use in output circuits of switch-mode power supplies of compact design For professional industrial electronics, telecommunications and data processing equipment Automotive electronics Features Low impedance at high frequency Low ESR High ripple current capability High reliability and long useful life RoHS-compatible Construction Radial leads Charge-discharge proof, polar Aluminum case with insulating sleeve Minus pole marking on the insulating sleeve Case with safety vent Delivery mode Terminal configurations and packing: Bulk Taped, Ammo pack Cut Kinked PAPR (protection against polarity reversal): crimped leads, J leads, bent leads Refer to chapter "Single-ended capacitors Taping, packing and lead configurations" for further details and ordering example.
Please read Cautions and warnings and Important notes at the end of this document.
Page 2 of 33
B41858 Low impedance 105 °C
Specifications and characteristics in brief Rated voltage VR Surge voltage VS Rated capacitance CR Capacitance tolerance Dissipation factor tan δ (20 °C, 120 Hz) 10 ... 100 V DC 1.15 VR 22 ... 10000 µF ±20% M For capacitance higher than 1000 µF add 0.02 for every increase of 1000 µF. VR (V DC) 10 16 25 35 50 63 100 tan δ (max.) Leakage current Ileak (20 °C, 5 min) Self-inductance ESL Useful life 105 °C; VR; IAC,R 105 °C; VR; IAC,R Requirements Diameter (mm) ESL (nH) 8 ... 12.5 20 16 26 18 34 0.19 0.16 0.14 0.12 0.10 0.10 0.08
> 3000 h for d = 8 mm > 5000 h for d ≥ 10 mm ∆C/C tan δ Ileak ≤ ±40% of initial value ≤ 3 times initial specified limit ≤ initial specified limit
Voltage endurance test 105 °C; VR Post test requirements
3000 h for d = 8 mm 5000 h for d ≥ 10 mm ∆C/C ≤ ±30% of initial value tan δ ≤ 2 times initial specified limit Ileak ≤ initial specified limit To IEC 60068-2-6, test Fc: Displacement amplitude 1.5 mm, frequency range 10 ... 2000 Hz, acceleration max. 20 g, duration 3 × 2 h. Capacitor rigidly clamped by the aluminum case. To IEC 60068-1: 55/105/56 ( 55 °C/+105 °C/56 days damp heat test) IEC 60384-4, AEC Q200
Vibration resistance test
IEC climatic category Sectional specification
Please read Cautions and warnings and Important notes at the end of this document.
Page 3 of 33
B41858 Low impedance 105 °C
Dimensional drawings With stand-off rubber seal Diameters (mm): 10, 12.5, 16, 18 With flat rubber seal Diameter (mm): 8
Dimensions and weights Dimensions (mm) d +0.5 8 10 10 10 12.5 12.5 12.5 12.5 16 16 16 18 18 18 18 18 Approx. weight g 1.0 1.6 1.9 2.6 3.6 4.5 5.3 7.4 5.5 7.5 7.8 8.0 9.0 11.0 13.0 16.0
l 11.5 +1.5 12.5 +1.0 16 +1.0 20 +2.0 20 +2.0 25 +2.0 30 +2.0 40 +2.0 20 +2.0 25 +2.0 31.5 +2.0 20 +2.0 25 +2.0 31.5 +2.0 35 +2.0 40 +2.0
a ±0.5 3.5 5.0 5.0 5.0 5.0 5.0 5.0 5.0 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5
b 0.60 ±0.05 0.60 ±0.05 0.60 ±0.05 0.60 ±0.05 0.60 ±0.05 0.60 ±0.05 0.80 ±0.05 0.80 ±0.05 0.80 ±0.05 0.80 ±0.05 0.80 ±0.05 0.80 ±0.1 0.80 ±0.1 0.80 ±0.1 0.80 ±0.1 0.80 ±0.1
Please read Cautions and warnings and Important notes at the end of this document.
Page 4 of 33
B41858 Low impedance 105 °C
Overview of available types VR (V DC) CR (µF) 120 150 180 220 270 330 390 470 560 680 820 1000 1200 1500 1800 2200 8 8 8 10 10 10 10 10 10 10 × 11.5 × 11.5 × 11.5 × 12.5 × 12.5 × 16 × 16 × 16 × 20 × 20 10 10 10 10 10 10 × 12.5 × 16 × 16 × 20 × 20 × 20 12.5 × 25 16 × 20 10 × 20 12.5 × 25 16 × 20 16 × 20 12.5 × 40 16 × 25 16 18 18 × 25 × 20 × 25 12.5 × 20 10 10 × 16 × 16 10 10 × 20 × 20 8 8 × 11.5 × 11.5 8 8 10 10 × 11.5 × 11.5 × 12.5 × 12.5 10 × 16 8 8 10 10 × 11.5 × 11.5 × 12.5 × 12.5 10 16 25 35
Case dimensions d × l (mm)
12.5 × 20
12.5 × 20 12.5 × 25 12.5 × 25
12.5 × 20
12.5 × 40 16 × 25 18 × 20 16 18 18 18 18 18 18 × 31.5 × 20 × 25 × 31.5 × 31.5 × 35 × 40
2700 3300 3900 4700 5600 6800 8200 10000
12.5 × 25 12.5 × 25 16 × 20 12.5 × 40 16 × 20 18 16 18 18 × 20 × 31.5 × 31.5 × 35 12.5 × 40
16
× 20
18 18 18 18
× 31.5 × 31.5 × 35 × 40
12.5 × 40 16 × 25 16 18 18 18 18 18 × 31.5 × 20 × 25 × 31.5 × 35 × 40
Please read Cautions and warnings and Important notes at the end of this document.
Page 5 of 33
B41858 Low impedance 105 °C
VR (V DC) CR (µF) 22 27 33 56 68 82 100 120 150 180 220 270 330 390 470 560 680
50
63
100
Case dimensions d × l (mm) 8 10 10 10 8 8 10 10 10 10 × 11.5 × 11.5 × 12.5 × 12.5 × 16 × 16 10 10 10 10 10 10 × 12.5 × 12.5 × 16 × 16 × 20 × 20 12.5 × 30 16 × 20 16 × 25 12.5 × 40 18 × 20 18 18 18 18 12.5 × 40 16 × 25 18 × 20 16 18 16 18 18 18 × 31.5 × 25 × 31.5 × 31.5 × 35 × 40 18 × 25 × 31.5 × 35 × 35 × 40 12.5 × 20 12.5 × 25 × 11.5 × 12.5 × 16 × 20
12.5 × 20 10 × 20 12.5 × 20 12.5 × 25 12.5 × 20 12.5 × 25 12.5 × 30 12.5 × 25 16 × 20
820 1000 1200 1500 1800 2200 2700
12.5 × 40 16 × 20 16 18 18 18 18 18 18 × 31.5 × 20 × 20 × 25 × 31.5 × 35 × 40
Other voltage and capacitance ratings are available upon request.
Please read Cautions and warnings and Important notes at the end of this document.
Page 6 of 33
B41858 Low impedance 105 °C
Technical data and ordering codes CR 120 Hz 20 °C µF Case ESRmax dimensions 10 kHz d×l 40 °C mm Ω 2.195 2.195 2.195 1.035 1.035 0.946 0.946 0.944 0.584 0.584 0.496 0.327 0.327 0.307 0.240 0.307 0.271 0.243 0.192 0.165 0.160 ESRmax 120 Hz 20 °C Ω 0.727 0.615 0.511 0.429 0.353 0.293 0.240 0.199 0.159 0.133 0.121 0.098 0.088 0.088 0.074 0.074 0.067 0.061 0.054 0.051 0.047 ESRmax 10 kHz 20 °C Ω 0.274 0.274 0.274 0.129 0.129 0.118 0.118 0.118 0.073 0.073 0.062 0.041 0.041 0.038 0.030 0.038 0.034 0.030 0.024 0.021 0.020 Zmax 100 kHz 20 °C Ω 0.246 0.246 0.246 0.113 0.113 0.105 0.105 0.105 0.062 0.062 0.060 0.034 0.034 0.033 0.025 0.033 0.031 0.025 0.022 0.020 0.018 IAC,R 100 kHz 105 °C mA 436 436 436 746 746 846 846 846 1202 1202 1396 2028 2028 2146 2858 2146 2381 2858 3122 3539 3864 IAC,max Ordering code 100 kHz (composition see 85 °C below) mA 654 654 654 1118 1118 1269 1269 1269 1803 1803 2094 3043 3043 3219 4287 3219 3571 4286 4683 5308 5796 B41858C3337M*** B41858C3397M*** B41858C3477M*** B41858C3567M*** B41858C3687M*** B41858C3827M*** B41858C3108M*** B41858C3128M*** B41858C3158M*** B41858C3188M*** B41858C3228M*** B41858C3278M*** B41858C3338M*** B41858D3338M*** B41858C3398M*** B41858D3398M*** B41858C3478M*** B41858C3568M*** B41858C3688M*** B41858C3828M*** B41858C3109M***
VR = 10 V DC 330 8 × 11.5 390 8 × 11.5 470 8 × 11.5 560 10 × 12.5 680 10 × 12.5 820 10 × 16 1000 10 × 16 1200 10 × 16 1500 10 × 20 1800 10 × 20 2200 12.5 × 20 2700 12.5 × 25 3300 12.5 × 25 3300 16 × 20 3900 12.5 × 40 3900 16 × 20 4700 18 × 20 5600 12.5 × 40 6800 16 × 31.5 8200 18 × 31.5 10000 18 × 35
Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm, excluding 12.5 × 30/40 mm) 002 = for cut leads, bulk (for ∅ ≥ 10 mm, excluding d × l = 12.5 × 30/40 mm) 003 = for crimped leads, blister (from d × l = 16 × 20 mm to 18 × 40 mm) 004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm, excluding 12.5 × 30/40 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 8 × 11.5 mm to 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and Important notes at the end of this document.
Page 7 of 33
B41858 Low impedance 105 °C
Technical data and ordering codes CR 120 Hz 20 °C µF Case ESRmax dimensions 10 kHz d×l 40 °C mm Ω 2.192 2.192 1.035 0.944 0.946 0.584 0.584 0.584 0.496 0.327 0.327 0.307 0.243 0.251 0.192 0.271 0.217 0.165 0.160 0.125 ESRmax 120 Hz 20 °C Ω 0.748 0.612 0.430 0.360 0.297 0.243 0.202 0.168 0.135 0.112 0.103 0.084 0.077 0.077 0.065 0.065 0.059 0.048 0.046 0.043 ESRmax 10 kHz 20 °C Ω 0.274 0.274 0.129 0.118 0.118 0.073 0.073 0.073 0.062 0.041 0.041 0.038 0.030 0.031 0.024 0.034 0.027 0.021 0.020 0.016 Zmax 100 kHz 20 °C Ω 0.246 0.246 0.113 0.105 0.105 0.062 0.062 0.062 0.060 0.034 0.034 0.033 0.025 0.029 0.022 0.031 0.024 0.020 0.018 0.015 IAC,R 100 kHz 105 °C mA 436 436 746 846 846 1202 1202 1202 1396 2028 2028 2146 2858 2483 3122 2381 2941 3539 3864 4467 IAC,max Ordering code 100 kHz (composition see 85 °C below) mA 654 654 1118 1269 1269 1803 1803 1803 2094 3043 3043 3219 4286 3724 4683 3571 4412 5308 5796 6700 B41858D4277M*** B41858D4337M*** B41858C4477M*** B41858C4567M*** B41858C4687M*** B41858C4827M*** B41858C4108M*** B41858C4128M*** B41858C4158M*** B41858C4188M*** B41858C4228M*** B41858C4278M*** B41858D4338M*** B41858C4338M*** B41858D4398M*** B41858C4398M*** B41858C4478M*** B41858C4688M*** B41858C4828M*** B41858C4109M***
VR = 16 V DC 270 8 × 11.5 330 8 × 11.5 470 10 × 12.5 560 10 × 16 680 10 × 16 820 10 × 20 1000 10 × 20 1200 10 × 20 1500 12.5 × 20 1800 12.5 × 25 2200 12.5 × 25 2700 16 × 20 3300 12.5 × 40 3300 16 × 25 3900 16 × 31.5 3900 18 × 20 4700 18 × 25 6800 18 × 31.5 8200 18 × 35 10000 18 × 40
Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm, excluding 12.5 × 30/40 mm) 002 = for cut leads, bulk (for ∅ ≥ 10 mm, excluding d × l = 12.5 × 30/40 mm) 003 = for crimped leads, blister (from d × l = 16 × 20 mm to 18 × 40 mm) 004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm, excluding 12.5 × 30/40 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 8 × 11.5 mm to 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and Important notes at the end of this document.
Page 8 of 33
B41858 Low impedance 105 °C
Technical data and ordering codes CR 120 Hz 20 °C µF Case ESRmax dimensions 10 kHz d×l 40 °C mm Ω 2.192 2.192 1.032 1.035 0.946 0.944 0.584 0.584 0.496 0.327 0.307 0.243 0.251 0.248 0.192 0.271 0.217 0.165 0.168 0.160 0.128 ESRmax 120 Hz 20 °C Ω 0.982 0.803 0.654 0.536 0.376 0.315 0.260 0.216 0.177 0.118 0.098 0.092 0.092 0.091 0.075 0.075 0.069 0.058 0.053 0.049 0.044 ESRmax 10 kHz 20 °C Ω 0.274 0.274 0.129 0.129 0.118 0.118 0.073 0.073 0.062 0.041 0.038 0.030 0.031 0.031 0.024 0.034 0.027 0.021 0.021 0.020 0.016 Zmax 100 kHz 20 °C Ω 0.246 0.246 0.113 0.113 0.105 0.105 0.062 0.062 0.060 0.034 0.033 0.025 0.029 0.031 0.022 0.031 0.024 0.020 0.020 0.018 0.015 IAC,R 100 kHz 105 °C mA 436 436 746 746 846 846 1202 1202 1396 2028 2146 2858 2483 2381 3122 2381 2941 3539 3539 3864 4467 IAC,max Ordering code 100 kHz (composition see 85 °C below) mA 654 654 1119 1118 1269 1269 1803 1803 2094 3043 3219 4286 3724 3572 4683 3571 4412 5308 5309 5796 6701 B41858D5187M*** B41858D5227M*** B41858C5277M*** B41858C5337M*** B41858C5477M*** B41858C5567M*** B41858C5687M*** B41858C5827M*** B41858C5108M*** B41858C5158M*** B41858C5188M*** B41858D5228M*** B41858C5228M*** B41858E5228M*** B41858D5278M*** B41858C5278M*** B41858C5338M*** B41858C5398M*** B41858D5478M*** B41858D5568M*** B41858C5688M***
VR = 25 V DC 180 8 × 11.5 220 8 × 11.5 270 10 × 12.5 330 10 × 12.5 470 10 × 16 560 10 × 16 680 10 × 20 820 10 × 20 1000 12.5 × 20 1500 12.5 × 25 1800 16 × 20 2200 12.5 × 40 2200 16 × 25 2200 18 × 20 2700 16 × 31.5 2700 18 × 20 3300 18 × 25 3900 18 × 31.5 4700 18 × 31.5 5600 18 × 35 6800 18 × 40
Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm, excluding 12.5 × 30/40 mm) 002 = for cut leads, bulk (for ∅ ≥ 10 mm, excluding d × l = 12.5 × 30/40 mm) 003 = for crimped leads, blister (from d × l = 16 × 20 mm to 18 × 40 mm) 004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm, excluding 12.5 × 30/40 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 8 × 11.5 mm to 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and Important notes at the end of this document.
Page 9 of 33
B41858 Low impedance 105 °C
Technical data and ordering codes CR 120 Hz 20 °C µF Case ESRmax dimensions 10 kHz d×l 40 °C mm Ω 2.192 2.192 1.035 1.035 0.946 0.584 0.584 0.496 0.327 0.304 0.307 0.243 0.251 0.248 0.271 0.217 0.165 0.168 0.160 0.125 ESRmax 120 Hz 20 °C Ω 1.263 1.010 0.842 0.689 0.459 0.323 0.271 0.223 0.152 0.151 0.126 0.101 0.101 0.084 0.084 0.080 0.065 0.061 0.051 0.048 ESRmax 10 kHz 20 °C Ω 0.274 0.274 0.129 0.129 0.118 0.073 0.073 0.062 0.041 0.038 0.038 0.030 0.031 0.031 0.034 0.027 0.021 0.021 0.020 0.016 Zmax 100 kHz 20 °C Ω 0.246 0.246 0.113 0.113 0.105 0.062 0.062 0.060 0.034 0.033 0.033 0.025 0.029 0.029 0.031 0.024 0.020 0.020 0.018 0.015 IAC,R 100 kHz 105 °C mA 436 436 746 746 846 1202 1202 1396 2028 2146 2146 2858 2483 2483 2381 2941 3539 3539 3864 4467 IAC,max Ordering code 100 kHz (composition see 85 °C below) mA 654 654 1118 1118 1269 1803 1803 2094 3043 3219 3219 4286 3724 3725 3571 4412 5308 5309 5796 6700 B41858D7127M*** B41858C7157M*** B41858C7187M*** B41858C7227M*** B41858C7337M*** B41858C7477M*** B41858C7567M*** B41858C7687M*** B41858C7108M*** B41858D7108M*** B41858C7128M*** B41858D7158M*** B41858C7158M*** B41858E7188M*** B41858C7188M*** B41858C7228M*** B41858C7278M*** B41858D7338M*** B41858C7398M*** B41858C7478M***
VR = 35 V DC 120 8 × 11.5 150 8 × 11.5 180 10 × 12.5 220 10 × 12.5 330 10 × 16 470 10 × 20 560 10 × 20 680 12.5 × 20 1000 12.5 × 25 1000 16 × 20 1200 16 × 20 1500 12.5 × 40 1500 16 × 25 1800 16 × 25 1800 18 × 20 2200 18 × 25 2700 18 × 31.5 3300 18 × 31.5 3900 18 × 35 4700 18 × 40
Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm, excluding 12.5 × 30/40 mm) 002 = for cut leads, bulk (for ∅ ≥ 10 mm, excluding d × l = 12.5 × 30/40 mm) 003 = for crimped leads, blister (from d × l = 16 × 20 mm to 18 × 40 mm) 004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm, excluding 12.5 × 30/40 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 8 × 11.5 mm to 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and Important notes at the end of this document.
Page 10 of 33
B41858 Low impedance 105 °C
Technical data and ordering codes CR 120 Hz 20 °C µF Case ESRmax dimensions 10 kHz d×l 40 °C mm Ω 5.168 5.168 2.984 2.984 1.400 1.400 1.000 0.880 0.712 0.360 0.269 0.401 0.260 0.477 0.384 0.382 0.300 0.268 0.210 ESRmax 120 Hz 20 °C Ω 1.540 1.263 1.053 0.842 0.702 0.574 0.383 0.269 0.226 0.186 0.154 0.154 0.126 0.126 0.105 0.084 0.070 0.069 0.065 ESRmax 10 kHz 20 °C Ω 0.646 0.646 0.373 0.373 0.175 0.175 0.125 0.110 0.089 0.045 0.034 0.050 0.032 0.048 0.048 0.038 0.030 0.027 0.021 Zmax 100 kHz 20 °C Ω 0.573 0.573 0.336 0.336 0.160 0.160 0.118 0.104 0.082 0.043 0.032 0.046 0.030 0.044 0.044 0.036 0.028 0.024 0.020 IAC,R 100 kHz 105 °C mA 340 340 555 555 778 778 1030 1300 1490 2140 2799 1820 2653 1997 1997 2417 2989 3320 3871 IAC,max Ordering code 100 kHz (composition see 85 °C below) mA 510 510 833 833 1167 1167 1545 1950 2235 3210 4199 2730 3980 2995 2996 3626 4483 4980 5807 B41858C6826M*** B41858C6107M*** B41858C6127M*** B41858C6157M*** B41858C6187M*** B41858C6227M*** B41858C6337M*** B41858C6477M*** B41858C6567M*** B41858C6687M*** B41858C6827M*** B41858D6827M*** B41858C6108M*** B41858D6108M*** B41858C6128M*** B41858C6158M*** B41858C6188M*** B41858C6228M*** B41858C6278M***
VR = 50 V DC 82 8 × 11.5 100 8 × 11.5 120 10 × 12.5 150 10 × 12.5 180 10 × 16 220 10 × 16 330 10 × 20 470 12.5 × 20 560 12.5 × 25 680 12.5 × 30 820 12.5 × 40 820 16 × 20 1000 16 × 31.5 1000 18 × 20 1200 18 × 20 1500 18 × 25 1800 18 × 31.5 2200 18 × 35 2700 18 × 40
Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm, excluding 12.5 × 30/40 mm) 002 = for cut leads, bulk (for ∅ ≥ 10 mm, excluding d × l = 12.5 × 30/40 mm) 003 = for crimped leads, blister (from d × l = 16 × 20 mm to 18 × 40 mm) 004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm, excluding 12.5 × 30/40 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 8 × 11.5 mm to 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and Important notes at the end of this document.
Page 11 of 33
B41858 Low impedance 105 °C
Technical data and ordering codes CR 120 Hz 20 °C µF Case ESRmax dimensions 10 kHz d×l 40 °C mm Ω 5.413 4.328 5.766 4.616 3.075 2.464 1.986 1.592 1.688 1.688 1.236 0.992 1.037 0.717 0.772 0.960 0.541 0.761 0.432 0.518 0.441 0.375 ESRmax 120 Hz 20 °C Ω 2.256 1.857 1.540 1.263 1.053 0.842 0.702 0.574 0.468 0.383 0.324 0.268 0.269 0.186 0.186 0.186 0.154 0.154 0.126 0.105 0.084 0.070 ESRmax 10 kHz 20 °C Ω 0.541 0.541 0.577 0.577 0.308 0.308 0.199 0.199 0.169 0.169 0.124 0.124 0.104 0.072 0.077 0.096 0.054 0.076 0.054 0.052 0.044 0.038 Zmax 100 kHz 20 °C Ω 0.488 0.488 0.500 0.500 0.279 0.279 0.180 0.180 0.153 0.153 0.112 0.112 0.094 0.065 0.070 0.087 0.049 0.069 0.049 0.047 0.040 0.034 IAC,R 100 kHz 105 °C mA 310 310 354 354 519 519 705 705 876 876 1118 1118 1272 1785 1600 1427 2092 1735 2092 2294 2592 2967 IAC,max Ordering code 100 kHz (composition see 85 °C below) mA 464 465 531 531 779 779 1058 1058 1315 1315 1676 1677 1907 2677 2400 2140 3138 2602 3138 3441 3888 4450 B41858C8566M*** B41858C8686M*** B41858C8826M*** B41858C8107M*** B41858C8127M*** B41858C8157M*** B41858C8187M*** B41858C8227M*** B41858C8277M*** B41858C8337M*** B41858C8397M*** B41858E8477M*** B41858C8477M*** B41858C8687M*** B41858D8687M*** B41858E8687M*** B41858C8827M*** B41858D8827M*** B41858C8108M*** B41858C8128M*** B41858C8158M*** B41858C8188M***
VR = 63 V DC 56 8 × 11.5 68 8 × 11.5 82 10 × 12.5 100 10 × 12.5 120 10 × 16 150 10 × 16 180 10 × 20 220 10 × 20 270 12.5 × 20 330 12.5 × 20 390 12.5 × 25 470 12.5 × 25 470 16 × 20 680 12.5 × 40 680 16 × 25 680 18 × 20 820 16 × 31.5 820 18 × 25 1000 16 × 31.5 1200 18 × 31.5 1500 18 × 35 1800 18 × 40
Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm, excluding 12.5 × 30/40 mm) 002 = for cut leads, bulk (for ∅ ≥ 10 mm, excluding d × l = 12.5 × 30/40 mm) 003 = for crimped leads, blister (from d × l = 16 × 20 mm to 18 × 40 mm) 004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm, excluding 12.5 × 30/40 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 8 × 11.5 mm to 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and Important notes at the end of this document.
Page 12 of 33
B41858 Low impedance 105 °C
Technical data and ordering codes CR 120 Hz 20 °C µF Case ESRmax dimensions 10 kHz d×l 40 °C mm Ω ESRmax 120 Hz 20 °C Ω ESRmax 10 kHz 20 °C Ω 1.222 0.981 0.654 0.461 0.305 0.204 0.173 0.131 0.099 0.131 0.126 0.097 0.101 0.072 0.068 0.068 0.044 Zmax 100 kHz 20 °C Ω 1.114 0.883 0.589 0.423 0.281 0.188 0.159 0.122 0.091 0.121 0.119 0.090 0.095 0.068 0.063 0.063 0.042 IAC,R 100 kHz 105 °C mA 205 266 357 460 647 864 1009 1119 1402 1309 1220 1546 1477 1907 2061 2061 2683 IAC,max Ordering code 100 kHz (composition see 85 °C below) mA 307 400 536 691 971 1296 1514 1678 2103 1963 1830 2319 2215 2861 3092 3092 4025 B41858C9226M*** B41858C9276M*** B41858C9336M*** B41858C9566M*** B41858C9107M*** B41858C9127M*** B41858C9187M*** B41858D9187M*** B41858C9227M*** B41858C9277M*** B41858D9277M*** B41858C9337M*** B41858D9337M*** B41858C9397M*** B41858C9477M*** B41858C9567M*** B41858C9687M***
VR = 100 V DC 22 8 × 11.5 12.219 4.593 27 10 × 12.5 9.813 3.743 33 10 × 16 6.542 3.062 56 10 × 20 4.606 1.804 100 12.5 × 20 3.048 1.011 120 12.5 × 25 2.038 0.842 180 12.5 × 30 1.732 0.561 180 16 × 20 1.313 0.561 220 16 × 25 0.985 0.459 270 12.5 × 40 1.314 0.374 270 18 × 20 1.260 0.374 330 16 × 31.5 0.973 0.306 330 18 × 25 1.008 0.306 390 18 × 31.5 0.720 0.259 470 18 × 35 0.679 0.215 560 18 × 35 0.679 0.180 680 18 × 40 0.438 0.149
Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm, excluding 12.5 × 30/40 mm) 002 = for cut leads, bulk (for ∅ ≥ 10 mm, excluding d × l = 12.5 × 30/40 mm) 003 = for crimped leads, blister (from d × l = 16 × 20 mm to 18 × 40 mm) 004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm, excluding 12.5 × 30/40 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 8 × 11.5 mm to 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and Important notes at the end of this document.
Page 13 of 33
B41858 Low impedance 105 °C
Useful life depending on ambient temperature TA under ripple current operating conditions1) d = 8 mm
d ≥ 10 mm
1) Refer to chapter "General technical information, 5.3 Calculation of useful life" for an explanation on how to interpret the useful life graphs.
Please read Cautions and warnings and Important notes at the end of this document.
Page 14 of 33
B41858 Low impedance 105 °C
Frequency factor of permissible ripple current IAC versus frequency f
Please read Cautions and warnings and Important notes at the end of this document.
Page 15 of 33
B41858 Low impedance 105 °C
Taping, packing and lead configurations Taping Single-ended capacitors are available taped in Ammo pack from diameter 5 to 18 mm as follows: Lead spacing F = 2.5 mm (∅ d = 5 … 6.3 mm) Lead spacing F = 3.5 mm (∅ d = 8 mm) Lead spacing F = 5.0 mm (from d × l = 10 × 12.5 mm to 12.5 × 30 mm) Lead spacing F = 7.5 mm (∅ d = 16 ... 18 mm). Lead spacing 2.5 mm (∅ d = 5 ... 6.3 mm) Last 3 digits of ordering code: 007
Dimensions in mm ∅d 5 F H W W0 W1 W2 H0 P P0 P1 I1 t ∆h D0
2.5 18.5 18.0 5.5 9.0 1.5 16.0 12.7 12.7 5.1 1.0 0.7 1.0 4.0 6.3 Toler- +0.8 ±0.75 ±0.5 min. ±0.5 max. ±0.5 ±1.0 ±0.2 ±0.5 max. ±0.2 max. ±0.2 ance 0.2
Please read Cautions and warnings and Important notes at the end of this document.
Page 16 of 33
B41858 Low impedance Lead spacing 3.5 mm (∅ d = 8 mm) Last 3 digits of ordering code: 006 105 °C
Dimensions in mm ∅d F H 8 3.5 18.5 Toler- +0.8 ±1.0 ance 0.2 W 18.0 ±0.5 W0 12.5 min. W1 9.0 ±0.5 W2 1.5 P 12.7 P0 12.7 ±0.2 P1 4.6 ±0.5 I1 1.0 t 0.7 ∆h 1.0 D0 4.0
max. ±1.0
max. ±0.2
max. ±0.2
Please read Cautions and warnings and Important notes at the end of this document.
Page 17 of 33
B41858 Low impedance 105 °C
Lead spacing 5.0 mm (∅ d = 5 ... 8 mm) Last 3 digits of ordering code: 008
Lead spacing 5.0 mm (from d × l = 10 × 12.5 mm to 12.5 × 30 mm) Last 3 digits of ordering code: 008
Dimensions in mm ∅d 5 6.3 8 10 5.0 F 5.0 H 18.5 20.0 19.0 18.0 12.5 9.0 1.5 W W0 W1 9.0 W2 1.5 H0 16.0 16.0 P 12.7 12.7 12.7 15.0 ±1.0 P0 12.7 12.7 12.7 15.0 ±0.2 P1 3.85 3.85 3.85 5.0 ±0.5 max. ±0.2 max. ±0.2 1.0 0.7 1.0 4.0 I1 1.0 t 0.7 ∆h 1.0 D0 4.0
18.0 5.5
12.5 19.0 Toler- +0.8 ±0.75 ±0.5 min. ±0.5 max. ±0.5 ance 0.2
Please read Cautions and warnings and Important notes at the end of this document.
Page 18 of 33
B41858 Low impedance Lead spacing 7.5 mm (∅ d = 16 ...18 mm) Last 3 digits of ordering code: 009 105 °C
Dimensions in mm ∅d 16 F H W W0 12.5 min. W1 9.0 ±0.5 W2 1.5 P 30.0 P0 15.0 ±0.2 P1 3.75 ±0.5 I1 1.0 t 0.7 ∆P 0 ∆h 0 D0 4.0
7.5 18.5 18.0 18 *) Toler0.5 ±0.8 ±0.5 ance +0.75
max. ±1.0
max. ±0.2 ±1.0 ±1.0 ±0.2
*) Available only for case dimensions 18 × 20, 18 × 25 and 18 × 31.5 mm
Please read Cautions and warnings and Important notes at the end of this document.
Page 19 of 33
B41858 Low impedance 105 °C
Packing units and box dimensions Ammo pack Case size d×l mm 5 × 11 6.3 × 11 8 × 11.5 10 × 12.5 10 × 16 10 × 20 12.5 × 20 12.5 × 25 16 × 20 16 × 25 16 × 31.5 18 × 20 18 × 25 18 × 31.5 Dimensions (mm) Amax 345 345 345 345 345 345 345 345 315 315 315 315 315 315 Bmax 55 55 55 55 60 60 65 65 65 65 65 65 65 65 Cmax 240 290 240 280 200 200 280 280 275 275 275 275 275 275 Packing units pcs. 2000 2000 1000 750 500 500 500 500 300 300 300 250 250 250
Please read Cautions and warnings and Important notes at the end of this document.
Page 20 of 33
B41858 Low impedance 105 °C
Kinked or cut leads Single-ended capacitors are available with kinked or cut leads. Other lead configurations also available upon request. Kinked leads Last 3 digits of ordering code: 001 With stand-off rubber seal Case size d × l (mm) 10 × 20 12.5 × 20 12.5 × 25 16 × 20 16 × 25 16 × 31.5 18 × 20 18 × 25 18 × 31.5 18 × 35 18 × 40 With flat rubber seal Dimensions (mm) a ±0.5 5.0 5.0 5.0 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5
Please read Cautions and warnings and Important notes at the end of this document.
Page 21 of 33
B41858 Low impedance 105 °C
Cut leads Last 3 digits of ordering code: 002 With stand-off rubber seal Case size d × l (mm) 10 × 12.5 10 × 16 10 × 20 12.5 × 20 12.5 × 25 With flat rubber seal 16 × 20 16 × 25 16 × 31.5 18 × 20 18 × 25 18 × 31.5 18 × 35 18 × 40 20 × 20 20 × 25 20 × 30 20 × 35 20 × 40 22 × 30 22 × 35 22 × 40 Dimensions (mm) a ±0.5 5.0 5.0 5.0 5.0 5.0 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0
Please read Cautions and warnings and Important notes at the end of this document.
Page 22 of 33
B41858 Low impedance 105 °C
PAPR leads (Protection Against Polarity Reversal) These lead configurations ensure correct placement of the capacitor on the PCB with regard to polarity. PAPR leads are available for diameters from 10 mm up to 20 mm. There are three configurations available: Crimped leads, J leads, bent 90° leads Crimped leads Last 3 digits of ordering code: 003 With stand-off rubber seal With flat rubber seal
Suggestion for PCB hole diameter
Case size d × l (mm) 16 × 20 16 × 25 16 × 31.5 18 × 20 18 × 25 18 × 31.5 18 × 35 18 × 40 20 × 20 20 × 25 20 × 30 20 × 35 20 × 40
Dimensions (mm) B ±0.2 C ±0.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0
D ±0.1 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.6 1.6 1.6 1.6 1.6
E ±0.1 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
a ±0.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 10.0 10.0 10.0 10.0 10.0
∅b 0.8 ±0.05 0.8 ±0.05 0.8 ±0.05 0.8 ±0.1 0.8 ±0.1 0.8 ±0.1 0.8 ±0.1 0.8 ±0.1 1.0 ±0.1 1.0 ±0.1 1.0 ±0.1 1.0 ±0.1 1.0 ±0.1
Please read Cautions and warnings and Important notes at the end of this document.
Page 23 of 33
B41858 Low impedance 105 °C
J leads Last 3 digits of ordering code: 004
Suggestion for PCB hole diameter
Case size d × l (mm) 10 × 12.5 10 × 16 10 × 20 12.5 × 20 12.5 × 25 16 × 20 16 × 25 16 × 31.5 18 × 20 18 × 25 18 × 31.5 18 × 35
Dimensions (mm) C ±0.5 E ±0.5 3.2 3.2 3.2 3.2 3.2 3.5 3.5 3.5 3.5 3.5 3.5 3.5 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
J ±0.2 1.2 1.2 1.2 1.2 1.2 1.6 1.6 1.6 1.6 1.6 1.6 1.6
a ±0.5 5.0 5.0 5.0 5.0 5.0 7.5 7.5 7.5 7.5 7.5 7.5 7.5
∅b 0.6 ±0.05 0.6 ±0.05 0.6 ±0.05 0.6 ±0.05 0.6 ±0.05 0.8 ±0.05 0.8 ±0.05 0.8 ±0.05 0.8 ±0.1 0.8 ±0.1 0.8 ±0.1 0.8 ±0.1
Please read Cautions and warnings and Important notes at the end of this document.
Page 24 of 33
B41858 Low impedance Bent 90° leads for horizontal mounting pinning Last 3 digits of ordering code: 012 105 °C
Case size d × l (mm) 16 × 20 16 × 25 16 × 31.5 18 × 20 18 × 25 18 × 31.5 18 × 35 18 × 40
Dimensions (mm) C ±0.5 E ±0.5 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0
F ±0.5 12.0 12.0 12.0 13.0 13.0 13.0 13.0 13.0
a ±0.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5
∅b 0.8 ±0.05 0.8 ±0.05 0.8 ±0.05 0.8 ±0.1 0.8 ±0.1 0.8 ±0.1 0.8 ±0.1 0.8 ±0.1
Bent leads for diameter 12.5 mm available upon request.
Please read Cautions and warnings and Important notes at the end of this document.
Page 25 of 33
B41858 Low impedance 105 °C
Overview of packing units and code numbers for case sizes 5 × 11 ... 16 × 31.5 PAPR Case size d×l mm 5 × 11 6.3 × 11 8 × 11.5 10 × 12.5 10 × 16 10 × 20 12.5 × 20 12.5 × 25 12.5 × 30 12.5 × 35 12.5 × 40 16 × 20 16 × 25 16 × 31.5 The last three digits of the complete ordering code state the lead configuration Standard, bulk pcs. 2000 2500 1000 1000 1000 500 350 250 200 175 175 250 250 200 000 300 300 300 Code 006 007 008 009 F (mm) d (mm) 3.5 2.5 5 7.5 8 5...6.3 5...12.5 16...18 200 200 250 001 200 200 250 002 200 200 344 003 200 200 344 004 120 120 120 012 Taped, Ammo pack pcs. 2000 2000 1000 750 500 500 500 500 500 350 500 1000 1000 500 350 500 675 675 500 300 225
1) 1)
Kinked leads, bulk pcs.
Cut leads, bulk pcs.
Crimped J leads, leads, blister blister pcs. pcs.
Bent 90° leads, blister pcs.
1) Available upon request
Please read Cautions and warnings and Important notes at the end of this document.
Page 26 of 33
B41858 Low impedance 105 °C
Overview of packing units and code numbers for case sizes 18 × 20 ... 25 × 40 PAPR Case size d×l mm 18 × 20 18 × 25 18 × 31.5 18 × 35 18 × 40 20 × 20 20 × 25 20 × 30 20 × 35 20 × 40 22 × 30 22 × 35 22 × 40 25 × 40 The last three digits of the complete ordering code state the lead configuration Standard, bulk pcs. 175 150 100 100 125 125 125 100 100 100 80 80 80 40 000 Code 007 008 009 F (mm) d (mm) 2.5 5 7.5 4...6.3 6.3...12.5 16...18 001 002 003 004 012 Taped, Ammo pack pcs. 250 250 250 Kinked leads, bulk pcs. 175 150 100 100 100 Cut leads, bulk pcs. 175 150 100 100 100 125 125 100 100 100 100 100 100 Crimped J leads, leads, blister blister pcs. pcs. 200 200 150 150 120 200 200 120 120 120 200 200 150 150 Bent 90° leads, blister pcs. 120 120 120 150 72
Please read Cautions and warnings and Important notes at the end of this document.
Page 27 of 33
B41858 Low impedance 105 °C
Cautions and warnings Personal safety The electrolytes used by EPCOS have not only been optimized with a view to the intended application, but also with regard to health and environmental compatibility. They do not contain any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide (DMAC). Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They contain flame-retarding substances which will quickly extinguish any flame that may have been ignited. As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce operating electrolytes. However, in exceptional cases, such materials must be used in order to achieve specific physical and electrical properties because no safe substitute materials are currently known. However, the amount of dangerous materials used in our products has been limited to an absolute minimum. Nevertheless, the following rules should be observed when handling Al electrolytic capacitors: Any escaping electrolyte should not come into contact with eyes or skin. If electrolyte does come into contact with the skin, wash the affected parts immediately with running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If symptoms persist, seek medical treatment. Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be well ventilated. Clothing that has been contaminated by electrolyte must be changed and rinsed in water.
Please read Cautions and warnings and Important notes at the end of this document.
Page 28 of 33
B41858 Low impedance 105 °C
Product safety The table below summarize the safety instructions that must be observed without fail. A detailed description can be found in the relevant sections of chapter "General technical information". Topic Safety information Reference Chapter "General technical information" 1 "Basic construction of aluminum electrolytic capacitors" 3.1.6 "Reverse voltage" 7.2 "Maximum permissible operating temperature" 10 "Maintenance"
Polarity
Make sure that polar capacitors are connected with the right polarity.
Reverse voltage Upper category temperature Maintenance
Voltages polarity classes should be prevented by connecting a diode. Do not exceed the upper category temperatur.
Mounting position of screw terminal capacitors Mounting of single-ended capacitors
Make periodic inspections of the capacitors. Before the inspection, make sure that the power supply is turned off and carefully discharge the electricity of the capacitors. Do not apply any mechanical stress to the capacitor terminals. Do not mount the capacitor with the terminals (safety vent) upside down.
Robustness of terminals
Soldering
11.1 "Mounting positions of capacitors with screw terminals" The internal structure of single-ended capacitors 11.4 might be damaged if excessive force is applied to "Mounting the lead wires. considerations for Avoid any compressive, tensile or flexural stress. single-ended capacitors" Do not move the capacitor after soldering to PC board. Do not pick up the PC board by the soldered capacitor. Do not insert the capacitor on the PC board with a hole space different to the lead space specified. The following maximum tightening torques must 11.3 not be exceeded when connecting screw "Mounting torques" terminals: M5: 2 Nm M6: 2.5 Nm Do not exceed the specified time or temperature 11.5 limits during soldering. "Soldering"
Page 29 of 33
Please read Cautions and warnings and Important notes at the end of this document.
B41858 Low impedance 105 °C
Topic
Safety information
Soldering, cleaning agents Passive flammability Active flammability
Reference Chapter "General technical information" Do not allow halogenated hydrocarbons to come 11.6 into contact with aluminum electrolytic capacitors. "Cleaning agents" Avoid external energy, such as fire or electricity. 8.1 "Passive flammability" Avoid overload of the capacitors. 8.2 "Active flammability" Reference Chapter "Capacitors with screw terminals" "Screw terminals accessories"
Breakdown strength Do not damage the insulating sleeve, especially of insulating when ring clips are used for mounting. sleeves
Please read Cautions and warnings and Important notes at the end of this document.
Page 30 of 33
B41858 Low impedance 105 °C
Symbols and terms Symbol C CR CS CS,T Cf d dmax ESL ESR ESRf ESRT f I IAC IAC,rms IAC,f IAC,max IAC,R IAC,R (B) Ileak Ileak,op l lmax R Rins Rsymm T ∆T TA TC TB t ∆t tb English Capacitance Rated capacitance Series capacitance Series capacitance at temperature T Capacitance at frequency f Case diameter, nominal dimension Maximum case diameter Self-inductance Equivalent series resistance Equivalent series resistance at frequency f Equivalent series resistance at temperature T Frequency Current Alternating current (ripple current) Root-mean-square value of alternating current Ripple current at frequency f Maximum permissible ripple current Rated ripple current Rated ripple current for base cooling Leakage current Operating leakage current Case length, nominal dimension Maximum case length (without terminals and mounting stud) Resistance Insulation resistance Balancing resistance Temperature Temperature difference Ambient temperature Case temperature Capacitor base temperature Time Period Service life (operating hours) German Kapazität Nennkapazität Serienkapazität Serienkapazität bei Temperatur T Kapazität bei Frequenz f Gehäusedurchmesser, Nennmaß Maximaler Gehäusedurchmesser Eigeninduktivität Ersatzserienwiderstand Ersatzserienwiderstand bei Frequenz f Ersatzserienwiderstand bei Temperatur T Frequenz Strom Wechselstrom Wechselstrom, Effektivwert Wechselstrom bei Frequenz f Maximal zulässiger Wechselstrom Nennwechselstrom Nennwechselstromstrom für Bodenkühlung Ableitstrom Ableitstrom bei Betrieb Gehäuselänge, Nennmaß Maximale Gehäuselänge (ohne Anschlüsse und Gewindebolzen) Widerstand Isolationswiderstand Symmetrierwiderstand Temperatur Temperaturdifferenz Umgebungstemperatur Gehäusetemperatur Temperatur des Becherbodens Zeit Zeitraum Brauchbarkeitsdauer (Betriebszeit)
Please read Cautions and warnings and Important notes at the end of this document.
Page 31 of 33
B41858 Low impedance 105 °C
Symbol V VF Vop VR VS XC XL Z ZT tan δ λ ε0 εr ω Notes
English Voltage Forming voltage Operating voltage Rated voltage, DC voltage Surge voltage Capacitive reactance Inductive reactance Impedance Impedance at temperature T Dissipation factor Failure rate Absolute permittivity Relative permittivity Angular velocity; 2 π f
German Spannung Formierspannung Betriebsspannung Nennspannung, Gleichspannung Spitzenspannung Kapazitiver Blindwiderstand Induktiver Blindwiderstand Scheinwiderstand Scheinwiderstand bei Temperatur T Verlustfaktor Ausfallrate Elektrische Feldkonstante Dielektrizitätszahl Kreisfrequenz; 2 π f
All dimensions are given in mm.
Please read Cautions and warnings and Important notes at the end of this document.
Page 32 of 33
Important notes
The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSSP, CTVS, DSSP, MiniBlue, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks.
Page 33 of 33