0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
B43474A4338M000

B43474A4338M000

  • 厂商:

    EPCOS

  • 封装:

  • 描述:

    B43474A4338M000 - Aluminum electrolytic capacitors - EPCOS

  • 数据手册
  • 价格&库存
B43474A4338M000 数据手册
Aluminum electrolytic capacitors Capacitors with screw terminals Series/Type: Date: B43454, B43474 November 2008 © EPCOS AG 2008. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Capacitors with screw terminals Standard 85 °C B43454, B43474 General-purpose grade capacitors Applications Uninterruptible power supplies Frequency converters Features All-welded construction ensures reliable electrical contact Self-extinguishing electrolyte RoHS-compatible Construction Charge-discharge proof, polar Aluminum case with insulating sleeve Poles with screw terminal connections Mounting with ring clips, clamps or threaded stud The bases of types with threaded stud and d ≤ 76.9 mm are not insulated B43454 B43474 Please read Cautions and warnings and Important notes at the end of this document. Page 2 of 16 B43454, B43474 Standard 85 °C Specifications and characteristics in brief Rated voltage VR Surge voltage VS Rated capacitance CR Capacitance tolerance Leakage current Ileak (20 °C, 5 min) Self-inductance ESL Useful life 85 °C; VR; IAC,R 40 °C; VR; 1.5 IAC,R d = 51.6 mm: approx. 15 nH d ≥ 64.3 mm: approx. 20 nH > 5000 h > 75000 h 350 ... 450 V DC 1.10 VR 1000 ... 12000 µF ±20% M Requirements: ∆C/C ≤ ±30% of initial value ESR ≤ 3 times initial specified limit Ileak ≤ initial specified limit Voltage endurance test Post test requirements: 85 °C; VR 2000 h ∆C/C ≤ ±10% of initial value ESR ≤ 1.3 times initial specified limit Ileak ≤ initial specified limit Vibration resistance test To IEC 60068-2-6, test Fc: Displacement amplitude 0.75 mm, frequency range 10 ... 55 Hz, acceleration max. 10 g, duration 3 × 2 h. Capacitor mounted by its body which is rigidly clamped to the work surface. Characteristics at low temperature Max. impedance ratio at 100 Hz VR Z -25°C / Z 20°C Z -40°C / Z 20°C IEC climatic category 350 V 6 22 400 V 5 20 450 V 4 16 To IEC 60068-1: 25/085/56 ( 25 °C/+85 °C/56 days damp heat test) The capacitors can be operated in the temperature range of 40 °C to +85 °C but the impedance at 40 °C should be taken into consideration. Similar to CECC 30301-810 IEC 60384-4 Detail specification Sectional specification Ripple current capability Due to the ripple current capability of the contact elements, the following current upper limits must not be exceeded: Capacitor diameter IAC,max Please read Cautions and warnings and Important notes at the end of this document. 51.6 mm 30 A Page 3 of 16 64.3 mm 40 A 76.9 mm 50 A B43454, B43474 Standard 85 °C Dimensional drawings B43454 Ring clip/clamp mounting B43474 Threaded stud mounting For types with threaded stud and d ≤ 76 mm the base is not insulated. Also refer to the mounting instructions in chapter "Capacitors with screw terminals Accessories". Dimensions and weights Terminal M5 M5 M5 M5 M5 M5 M5 M5 M5 Dimensions (mm) with insulating sleeve d l ±1 l1 ±1 l2 +0/ 1 d1 51.6 +0/ 0.8 80.7 51.6 +0/ 0.8 105.7 64.3 +0/ 0.8 80.7 64.3 +0/ 0.8 105.7 64.3 +0/ 0.8 143.2 76.9 +0/ 76.9 +0/ 76.9+0/ 76.9 +0/ 0.7 0.7 0.7 0.7 105.7 143.2 168.7 220.7 87.2 112.2 87.2 112.2 149.7 111.5 149.0 174.5 226.5 17 17 17 17 17 17 17 17 17 M12 M12 M12 M12 M12 M12 M12 M12 M12 Approx. weight (g) 220 280 370 440 630 620 840 1000 1300 d2 max. a +0.2/ 0.4 10.2 10.2 13.2 13.2 13.2 13.2 13.2 13.2 13.2 22.2 22.2 28.5 28.5 28.5 31.7 31.7 31.7 31.7 Please read Cautions and warnings and Important notes at the end of this document. Page 4 of 16 B43454, B43474 Standard 85 °C Packing Capacitor diameter d (mm) 51.6 64.3 76.9 lenght l (mm) all all 97.0 - 168.7 191.0 - 220.7 Packing units (pcs.) 36 25 16 12 For ecological reasons the packing is pure cardboard. Accessories The following items are included in the delivery package, but are not fastened to the capacitors: For terminals M5 A 5.1 DIN 6797 Cylinder-head screw M5 × 8 DIN 84-4.8 2.0 Nm 10 Nm For mounting M12 J 12.5 DIN 6797 Hex nut BM 12 DIN 439 The following items must be ordered separately. For details, refer to chapter "Screw terminals Accessories". Item Ring clips Clamps for capacitors with d ≥ 64.3 mm Insulating parts Please read Cautions and warnings and Important notes at the end of this document. Type B44030 B44030 B44020 Page 5 of 16 B43454, B43474 Standard 85 °C Overview of available types VR (V DC) CR (µF) 1000 1500 2200 2700 3300 3900 4700 5600 6800 8200 10000 12000 51.6 × 80.7 51.6 × 105.7 64.3 × 80.7 64.3 × 80.7 64.3 × 105.7 64.3 × 105.7 64.3 × 143.2 76.9 × 105.7 64.3 × 143.2 76.9 × 143.2 76.9 × 168.7 76.9 × 220.7 76.9 × 220.7 51.6 × 80.7 51.6 × 105.7 64.3 × 80.7 64.3 × 105.7 64.3 × 105.7 76.9 × 105.7 76.9 × 143.2 76.9 × 143.2 76.9 × 168.7 76.9 × 220.7 76.9 × 220.7 51.6 × 105.7 64.3 × 80.7 64.3 × 105.7 76.9 × 105.7 64.3 × 143.2 76.9 × 143.2 76.9 × 168.7 76.9 × 220.7 76.9 × 220.7 76.9 × 220.7 350 400 450 Case dimensions d × l (mm) The capacitance and voltage ratings listed above are available in different cases upon request. Other voltage and capacitance ratings are also available upon request. Please read Cautions and warnings and Important notes at the end of this document. Page 6 of 16 B43454, B43474 Standard 85 °C Technical data and ordering codes CR 100 Hz 20 °C µF Case dimensions d×l mm ESRtyp 100 Hz 20 °C mΩ 82 58 58 48 40 35 30 30 25 20 16 12 10 99 76 62 52 43 35 28 23 21 18 16 ESRmax 100 Hz 20 °C mΩ 123 87 87 72 60 53 45 45 38 30 24 18 15 149 114 93 78 65 53 42 35 32 27 24 Zmax 10 kHz 20 °C mΩ 98 70 70 58 48 42 36 36 30 24 19 14 12 119 91 74 62 52 42 34 28 25 22 19 IAC,max 100 Hz 40 °C A 14 18 18 21 24 26 30 29 34 40 47 50 50 12 15 18 21 24 28 32 37 40 46 50 IAC,R Ordering code 100 Hz (composition see below) 85 °C A 5.3 6.8 6.8 7.7 8.9 9.8 11.2 10.9 12.8 14.9 17.4 21.5 24.8 4.6 5.7 6.8 7.7 8.9 10.3 12.0 13.8 15.1 17.4 19.4 B434*4A4158M000 B434*4A4228M000 B434*4B4228M000 B434*4A4278M000 B434*4A4338M000 B434*4A4398M000 B434*4A4478M000 B434*4B4478M000 B434*4A4568M000 B434*4A4688M000 B434*4A4828M000 B434*4A4109M000 B434*4A4129M000 B434*4A9108M000 B434*4A9158M000 B434*4A9228M000 B434*4A9278M000 B434*4A9338M000 B434*4A9398M000 B434*4A9478M000 B434*4A9568M000 B434*4A9688M000 B434*4A9828M000 B434*4A9109M000 VR = 350 V DC 1500 51.6 × 80.7 2200 51.6 × 105.7 2200 64.3 × 80.7 2700 64.3 × 80.7 3300 64.3 × 105.7 3900 64.3 × 105.7 4700 64.3 × 143.2 4700 76.9 × 105.7 5600 64.3 × 143.2 6800 76.9 × 143.2 8200 76.9 × 168.7 10000 76.9 × 220.7 12000 76.9 × 220.7 VR = 400 V DC 1000 51.6 × 80.7 1500 51.6 × 105.7 2200 64.3 × 80.7 2700 64.3 × 105.7 3300 64.3 × 105.7 3900 76.9 × 105.7 4700 76.9 × 143.2 5600 76.9 × 143.2 6800 76.9 × 168.7 8200 76.9 × 220.7 10000 76.9 × 220.7 Composition of ordering code * = Mounting style 5 = for capacitors with ring clip/clamp mounting 7 = for capacitors with threaded stud Please read Cautions and warnings and Important notes at the end of this document. Page 7 of 16 B43454, B43474 Standard 85 °C Technical data and ordering codes CR 100 Hz 20 °C µF Case dimensions d×l mm ESRtyp 100 Hz 20 °C mΩ 120 74 54 46 39 34 29 25 21 19 ESRmax 100 Hz 20 °C mΩ 180 111 81 69 59 51 44 38 32 29 Zmax 10 kHz 20 °C mΩ 144 89 65 55 47 41 35 30 25 23 IAC,max 100 Hz 40 °C A 12 16 20 23 26 29 33 38 43 48 IAC,R Ordering code 100 Hz (composition see below) 85 °C A 4.4 6.0 7.6 8.8 9.9 11.0 12.4 14.1 16.1 17.8 B434*4A5108M000 B434*4A5158M000 B434*4A5228M000 B434*4A5278M000 B434*4A5338M000 B434*4A5398M000 B434*4A5478M000 B434*4A5568M000 B434*4A5688M000 B434*4A5828M000 VR = 450 V DC 1000 51.6 × 105.7 1500 64.3 × 80.7 2200 64.3 × 105.7 2700 76.9 × 105.7 3300 64.3 × 143.2 3900 76.9 × 143.2 4700 76.9 × 168.7 5600 76.9 × 220.7 6800 76.9 × 220.7 8200 76.9 × 220.7 Composition of ordering code * = Mounting style 5 = for capacitors with ring clip/clamp mounting 7 = for capacitors with threaded stud Please read Cautions and warnings and Important notes at the end of this document. Page 8 of 16 B43454, B43474 Standard 85 °C Useful life depending on ambient temperature TA under ripple current operating conditions1) Frequency factor of permissible ripple current IAC versus frequency f 1) Refer to chapter "General technical information, 5.3 Calculation of useful life" on how to interpret the useful life graphs. Please read Cautions and warnings and Important notes at the end of this document. Page 9 of 16 B43454, B43474 Standard 85 °C Frequency characteristics of ESR Typical behavior Impedance Z versus frequency f Typical behavior at 20 °C Please read Cautions and warnings and Important notes at the end of this document. Page 10 of 16 B43454, B43474 Standard 85 °C Cautions and warnings Personal safety The electrolytes used by EPCOS have not only been optimized with a view to the intended application, but also with regard to health and environmental compatibility. They do not contain any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide (DMAC). Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They contain flame-retarding substances which will quickly extinguish any flame that may have been ignited. As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce operating electrolytes. However, in exceptional cases, such materials must be used in order to achieve specific physical and electrical properties because no safe substitute materials are currently known. However, the amount of dangerous materials used in our products has been limited to an absolute minimum. Nevertheless, the following rules should be observed when handling Al electrolytic capacitors: Any escaping electrolyte should not come into contact with eyes or skin. If electrolyte does come into contact with the skin, wash the affected parts immediately with running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If symptoms persist, seek medical treatment. Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be well ventilated. Clothing that has been contaminated by electrolyte must be changed and rinsed in water. Please read Cautions and warnings and Important notes at the end of this document. Page 11 of 16 B43454, B43474 Standard 85 °C Product safety The table below summarize the safety instructions that must be observed without fail. A detailed description can be found in the relevant sections of chapter "General technical information". Topic Safety information Reference Chapter "General technical information" 1 "Basic construction of aluminum electrolytic capacitors" 3.1.6 "Reverse voltage" 7.2 "Maximum permissible operating temperature" 10 "Maintenance" Polarity Make sure that polar capacitors are connected with the right polarity. Reverse voltage Upper category temperature Maintenance Voltages polarity classes should be prevented by connecting a diode. Do not exceed the upper category temperatur. Mounting position of screw terminal capacitors Mounting of single-ended capacitors Make periodic inspections of the capacitors. Before the inspection, make sure that the power supply is turned off and carefully discharge the electricity of the capacitors. Do not apply any mechanical stress to the capacitor terminals. Do not mount the capacitor with the terminals (safety vent) upside down. Robustness of terminals Soldering 11.1. "Mounting positions of capacitors with screw terminals" The internal structure of single-ended capacitors 11.4 might be damaged if excessive force is applied to "Mounting the lead wires. considerations for Avoid any compressive, tensile or flexural stress. single-ended capacitors" Do not move the capacitor after soldering to PC board. Do not pick up the PC board by the soldered capacitor. Do not insert the capacitor on the PC board with a hole space different to the lead space specified. The following maximum tightening torques must 11.3 not be exceeded when connecting screw "Mounting torques" terminals: M5: 2 Nm M6: 2.5 Nm Do not exceed the specified time or temperature 11.5 limits during soldering. "Soldering" Page 12 of 16 Please read Cautions and warnings and Important notes at the end of this document. B43454, B43474 Standard 85 °C Topic Safety information Soldering, cleaning agents Passive flammability Active flammability Reference Chapter "General technical information" Do not allow halogenated hydrocarbons to come 11.6 into contact with aluminum electrolytic capacitors. "Cleaning agents" Avoid external energy, such as fire or electricity. 8.1 "Passive flammability" Avoid overload of the capacitors. 8.2 "Active flammability" Reference Chapter "Capacitors with screw terminals" "Screw terminals accessories" Breakdown strength Do not damage the insulating sleeve, especially of insulating when ring clips are used for mounting. sleeves Please read Cautions and warnings and Important notes at the end of this document. Page 13 of 16 B43454, B43474 Standard 85 °C Symbols and terms Symbol C CR CS CS,T Cf d dmax ESL ESR ESRf ESRT f I IAC IAC,rms IAC,f IAC,max IAC,R IAC,R (B) Ileak Ileak,op l lmax R Rins Rsymm T ∆T TA TC TB t ∆t tb English Capacitance Rated capacitance Series capacitance Series capacitance at temperature T Capacitance at frequency f Case diameter, nominal dimension Maximum case diameter Self-inductance Equivalent series resistance Equivalent series resistance at frequency f Equivalent series resistance at temperature T Frequency Current Alternating current (ripple current) Root-mean-square value of alternating current Ripple current at frequency f Maximum permissible ripple current Rated ripple current Rated ripple current for base cooling Leakage current Operating leakage current Case length, nominal dimension Maximum case length (without terminals and mounting stud) Resistance Insulation resistance Balancing resistance Temperature Temperature difference Ambient temperature Case temperature Capacitor base temperature Time Period Service life (operating hours) German Kapazität Nennkapazität Serienkapazität Serienkapazität bei Temperatur T Kapazität bei Frequenz f Gehäusedurchmesser, Nennmaß Maximaler Gehäusedurchmesser Eigeninduktivität Ersatzserienwiderstand Ersatzserienwiderstand bei Frequenz f Ersatzserienwiderstand bei Temperatur T Frequenz Strom Wechselstrom Wechselstrom, Effektivwert Wechselstrom bei Frequenz f Maximal zulässiger Wechselstrom Nennwechselstrom Nennwechselstromstrom für Bodenkühlung Ableitstrom Ableitstrom bei Betrieb Gehäuselänge, Nennmaß Maximale Gehäuselänge (ohne Anschlüsse und Gewindebolzen) Widerstand Isolationswiderstand Symmetrierwiderstand Temperatur Temperaturdifferenz Umgebungstemperatur Gehäusetemperatur Temperatur des Becherbodens Zeit Zeitraum Brauchbarkeitsdauer (Betriebszeit) Please read Cautions and warnings and Important notes at the end of this document. Page 14 of 16 B43454, B43474 Standard 85 °C Symbol V VF Vop VR VS XC XL Z ZT tan δ λ ε0 εr ω Notes English Voltage Forming voltage Operating voltage Rated voltage, DC voltage Surge voltage Capacitive reactance Inductive reactance Impedance Impedance at temperature T Dissipation factor Failure rate Absolute permittivity Relative permittivity Angular velocity; 2 π f German Spannung Formierspannung Betriebsspannung Nennspannung, Gleichspannung Spitzenspannung Kapazitiver Blindwiderstand Induktiver Blindwiderstand Scheinwiderstand Scheinwiderstand bei Temperatur T Verlustfaktor Ausfallrate Elektrische Feldkonstante Dielektrizitätszahl Kreisfrequenz; 2 π f All dimensions are given in mm. Please read Cautions and warnings and Important notes at the end of this document. Page 15 of 16 Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSSP, CTVS, DSSP, MiniBlue, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Page 16 of 16
B43474A4338M000 价格&库存

很抱歉,暂时无法提供与“B43474A4338M000”相匹配的价格&库存,您可以联系我们找货

免费人工找货