EMC filters
Series/Type:
B84142A*R122
The following products presented in this data sheet are being withdrawn.
Ordering Code
B84142A0180R122
B84142A0130R122
B84142A0100R122
Substitute Product
Date of
Withdrawal
2019-06-21
2019-06-21
2019-06-21
Deadline Last
Orders
2019-09-30
2019-09-30
2019-09-30
Last
Shipments
2019-12-31
2019-12-31
2019-12-31
Ordering Code
B84142A0075R122
B84142A0055R122
B84142A0042R122
B84142A0030R122
B84142A0016R122
B84142A0008R122
Substitute Product
Date of
Withdrawal
2019-06-21
2019-06-21
2019-06-21
2019-06-21
2019-06-21
2019-06-21
Deadline Last
Orders
2019-09-30
2019-09-30
2019-09-30
2019-09-30
2019-09-30
2019-09-30
Last
Shipments
2019-12-31
2019-12-31
2019-12-31
2019-12-31
2019-12-31
2019-12-31
Please contact your nearest TDK sales office if you need support in selecting a suitable
substitute. The addresses of our worldwide sales network are presented at www.tdkelectronics.tdk.com/sales.
2-line filters
B84142A*R122
for converters and power electronics
Power line filters for 1-phase systems
Rated voltage VR: 300 V AC/DC
Rated current IR: 8 A to 180 A
Construction
2-line filters
Metal case
Features
High insertion loss
Easy to install
Space-saving design
Low weight
Design complies with IEC 60939
UL and cUL approval
Typical applications
Power supplies
DC applications
Terminals
Finger-safe terminal blocks
Marking
Marking on component:
Manufacturer's logo, ordering code, rated voltage, rated
current, rated temperature, climatic category, date code,
approvals
Minimum data on packaging:
Manufacturer's logo, ordering code, quantity, date code
Typical circuit diagram
Please read Cautions and warnings and
Important notes at the end of this document.
Page 2 of 15
2-line filters
B84142A*R122
for converters and power electronics
Technical data and measuring conditions
Rated voltage VR
Rated current IR
Test voltage Vtest
300 V AC (50/60 Hz) / 300 V DC
Referred to 50 °C rated temperature
1700 V DC, 2 s (line/line)
3000 V DC, 2 s (lines/case)
1.5 IR for 3 min per hour or
2.5 IR for 30 s per hour
At VR and 50 Hz
25/100/21 (25 °C/+100 °C/21 days damp heat test)
UL 1283, CSA C22.2 No.8
Overload capability (thermal)
Leakage current lLK
Climatic category (IEC 60068-1)
Approvals
Characteristics and ordering codes
IR
A
Terminal cross
section
mm2
VR = 300 V AC/DC
8
4
16
4
30
10
42
10
55
10
75
16
100
35
130
50
180
95
ILK
Rtyp
Ordering code
Approvals
mΩ
Approx.
weight
kg
mA
32
32
32
45
45
45
95
95
95
15
9
5
4
3
1.5
1.1
0.7
0.5
0.7
1.1
1.7
1.9
1.9
2.6
5.0
8.0
8.0
B84142A0008R122
B84142A0016R122
B84142A0030R122
B84142A0042R122
B84142A0055R122
B84142A0075R122
B84142A0100R122
B84142A0130R122
B84142A0180R122
×
×
×
×
×
×
×
×
×
× = Approval granted
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 15
×
×
×
×
×
×
×
×
×
2-line filters
B84142A*R122
for converters and power electronics
Dimensional drawings
B84142A0008R122 (8 A)
General tolerances according to ISO 2768cL
Dimensions in mm
B84142A0016R122 (16 A)
General tolerances according to ISO 2768cL
Dimensions in mm
Please read Cautions and warnings and
Important notes at the end of this document.
Page 4 of 15
2-line filters
B84142A*R122
for converters and power electronics
B84142A0030R122 ... B84142A0055R122 (30 A, 42 A, 55 A)
General tolerances according to ISO 2768cL
Dimensions in mm
B84142A0075R122 (75 A)
General tolerances according to ISO 2768cL
Dimensions in mm
Please read Cautions and warnings and
Important notes at the end of this document.
Page 5 of 15
2-line filters
B84142A*R122
for converters and power electronics
B84142A0100R122 (100 A)
General tolerances according to ISO 2768cL
Dimensions in mm
B84142A0130R122 (130 A)
General tolerances according to ISO 2768cL
Dimensions in mm
Please read Cautions and warnings and
Important notes at the end of this document.
Page 6 of 15
2-line filters
B84142A*R122
for converters and power electronics
B84142A0180R122 (180 A)
General tolerances according to ISO 2768cL
Dimensions in mm
Please read Cautions and warnings and
Important notes at the end of this document.
Page 7 of 15
2-line filters
B84142A*R122
for converters and power electronics
Insertion loss (typical values at Z = 50 Ω)
Filters for 8 A
Filters for 16 A
Filters for 30 A
Filters for 42 A
Please read Cautions and warnings and
Important notes at the end of this document.
Page 8 of 15
2-line filters
B84142A*R122
for converters and power electronics
Insertion loss (typical values at Z = 50 Ω)
Filters for 55 A
Filters for 75 A
Filters for 100 A
Filters for 130 A
Please read Cautions and warnings and
Important notes at the end of this document.
Page 9 of 15
2-line filters
B84142A*R122
for converters and power electronics
Insertion loss (typical values at Z = 50 Ω)
Filters for 180 A
Please read Cautions and warnings and
Important notes at the end of this document.
Page 10 of 15
2-line filters
B84142A*R122
for converters and power electronics
Cautions and warnings
Please read all safety and warning notes carefully before installing the EMC filter and putting it
into operation (see ). The same applies to the warning signs on the filter. Please ensure that
the signs are not removed nor their legibility impaired by external influences.
Death, serious bodily injury and substantial material damage to equipment may occur if the
appropriate safety measures are not carried out or the warnings in the text are not observed.
Using according to the terms
The EMC filters may be used only for their intended application within the specified values in lowvoltage networks in compliance with the instructions given in the data sheets and the data book.
The conditions at the place of application must comply with all specifications for the filter used.
Warning
It shall be ensured that only qualified persons (electricity specialists) are engaged on work such
as planning, assembly, installation, operation, repair and maintenance. They must be provided
with the corresponding documentation.
Danger of electric shock. EMC filters contain components that store an electric charge. Dangerous voltages can continue to exist at the filter terminals for longer than five minutes even after
the power has been switched off.
The protective earth connections shall be the first to be made when the EMC filter is installed
and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed.
Impermissible overloading of the EMC filter or filter, such as with circuits able to cause resonances, impermissible voltages at higher frequencies etc. can lead to bodily injury and death as
well as cause substantial material damages (e.g. destruction of the filter housing).
EMC filters and filters must be protected in the application against impermissible exceeding of
the rated currents by overcurrent protective circuitry.
In case of leakage currents >3.5 mA you shall mount the PE conductor stationary with the
required cross section before beginning of operation and save it against disconnecting. For
leakage currents IL1) 250 A
Instructions
Reference chapter
(data book),
paragraph
For operating currents greater than 250 A, we Mounting
recommend the PE connection to be set up between instructions, point
the feed (filter: line) and output (filter: load) not via the 2
PE terminal bolt in the filter housing.
Mounting position
Note the mounting position of the filters! It must Mounting
always be ensured that natural convection is not instructions, point
impaired.
13
Long motor cables
Long motor cables cause parasitic currents in the
installation. The cable lengths indicated for the output
chokes and output filters serve for orientation. The
user must check the technical parameters and
especially the choke temperatures for the respective
application.
Mounting
instructions, point
15
Display of ordering codes for EPCOS products
The ordering code for one and the same product can be represented differently in data sheets,
data books, other publications and the website of EPCOS, or in order-related documents such as
shipping notes, order confirmations and product labels. The varying representations of the
ordering codes are due to different processes employed and do not affect the specifications of the
respective products. Detailed information can be found on the Internet under
www.epcos.com/orderingcodes
Please read Cautions and warnings and
Important notes at the end of this document.
Page 13 of 15
2-line filters
B84142A*R122
for converters and power electronics
Symbols and terms
Symbol
English
α
Insertion loss
CR
Rated capacitance
CX
Capacitance X capacitor
CY
Capacitance Y capacitor
∆V
Voltage drop (input to output)
dv/dt
Rate of voltage rise
f
Frequency
fM
Converter output frequency
fP
Pulse frequency
fR
Rated frequency
fres
Resonant frequency
IC
Current through capacitor
ILK
Filter leakage current
Imax
Maximum current
IN
Nominal current
Iop
Operating current (design current)
Ipk
Rated peak withstand current
Iq
Capacitive reactive current
IR
Rated current
IS
Interference current
L
Inductance
LR
Rated inductance
Lstray
Stray inductance
PL
Power loss
R
Resistance
Ris
Insulation resistance
Rtyp
DC resistance, typical value
TA
Ambient temperature
Tmax
Upper category temperature
Tmin
Lower category temperature
TR
Rated temperature
uk
Refered voltage drop in %
Veff
RMS voltage
VK
Voltage drop
VLE
Voltage line to earth; voltage line to ground
VN
Nominal voltage
VR
Rated voltage
Vpeak
Peak voltage
Vtest
Test voltage
VX
Voltage over X capacitor
VY
Voltage over Y capacitor
XL
Inductive reactance
Z
Impedance
|Z|
Impedance, absolute value
Please read Cautions and warnings and
Important notes at the end of this document.
Page 14 of 15
German
Einfügungsdämpfung
Bemessungskapazität
Kapazität X-Kondensator
Kapazität Y-Kondensator
Spannungsabfall im Filter
Spannungsanstiegsgeschwindigkeit
Frequenz
Motorfrequenz
Pulsfrequenz
Bemessungsfrequenz
Resonanzfrequenz
Strom durch Kondensator
Filter-Ableitstrom
Maximalstrom
Nennstrom
Betriebsstrom
Bemessungs-Stoßstromfestigkeit
Kapazitiver Blindstrom
Bemessungsstrom
Störstrom
Induktivität
Bemessungsinduktivität
Streuinduktivität
Verlustleistung
Widerstand
Isolationswiderstand
Gleichstromwiderstand, Richtwert
Umgebungstemperatur
Obere Kategorietemperatur
Untere Kategorietemperatur
Bemessungstemperatur
Bezogener Spannungsabfall in %
Effektivspannung
Spannungsabfall
Spannung Phase zu Erdpotential
Nennspannung
Bemessungsspannung
Spitzenspannung
Prüfspannung
Spannung über X-Kondensator
Spannung über Y-Kondensator
Induktiver Blindwiderstand
Scheinwidertand
Scheinwiderstand (Betragswert)
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for certain
areas of application. These statements are based on our knowledge of typical requirements that are
often placed on our products in the areas of application concerned. We nevertheless expressly point
out that such statements cannot be regarded as binding statements about the suitability of our
products for a particular customer application. As a rule we are either unfamiliar with individual
customer applications or less familiar with them than the customers themselves. For these reasons, it is
always ultimately incumbent on the customer to check and decide whether a product with the properties
described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or failure
before the end of their usual service life cannot be completely ruled out in the current state of the
art, even if they are operated as specified. In customer applications requiring a very high level of
operational safety and especially in customer applications in which the malfunction or failure of an
electronic component could endanger human life or health (e.g. in accident prevention or life-saving
systems), it must therefore be ensured by means of suitable design of the customer application or other
action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or
damage is sustained by third parties in the event of malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this publication
may contain substances subject to restrictions in certain jurisdictions (e.g. because they are
classed as hazardous). Useful information on this will be found in our Material Data Sheets on the
Internet (www.tdk-electronics.tdk.com/material). Should you have any more detailed questions, please
contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications contained
in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the foregoing for
customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to our General Terms and
Conditions of Supply.
7. Our manufacturing sites serving the automotive business apply the IATF 16949 standard. The
IATF certifications confirm our compliance with requirements regarding the quality management system
in the automotive industry. Referring to customer requirements and customer specific requirements
(“CSR”) TDK always has and will continue to have the policy of respecting individual agreements. Even
if IATF 16949 may appear to support the acceptance of unilateral requirements, we hereby like to
emphasize that only requirements mutually agreed upon can and will be implemented in our
Quality Management System. For clarification purposes we like to point out that obligations from IATF
16949 shall only become legally binding if individually agreed upon.
8. The trade names EPCOS, CeraCharge, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CTVS,
DeltaCap, DigiSiMic, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell, MKD, MKK, MotorCap,
PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PowerHap, PQSine, PQvar, SIFERRIT, SIFI,
SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, ThermoFuse, WindCap are
trademarks registered or pending in Europe and in other countries. Further information will be found
on the Internet at www.tdk-electronics.tdk.com/trademarks.
Release 2018-10
Page 15 of 15