0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
B84142A30R122

B84142A30R122

  • 厂商:

    TDK(东电化)

  • 封装:

    -

  • 描述:

    LINEFLTR300VDC300VAC30ACHAS

  • 数据手册
  • 价格&库存
B84142A30R122 数据手册
EMC filters Series/Type: B84142A*R122 The following products presented in this data sheet are being withdrawn. Ordering Code B84142A0180R122 B84142A0130R122 B84142A0100R122 Substitute Product Date of Withdrawal 2019-06-21 2019-06-21 2019-06-21 Deadline Last Orders 2019-09-30 2019-09-30 2019-09-30 Last Shipments 2019-12-31 2019-12-31 2019-12-31 Ordering Code B84142A0075R122 B84142A0055R122 B84142A0042R122 B84142A0030R122 B84142A0016R122 B84142A0008R122 Substitute Product Date of Withdrawal 2019-06-21 2019-06-21 2019-06-21 2019-06-21 2019-06-21 2019-06-21 Deadline Last Orders 2019-09-30 2019-09-30 2019-09-30 2019-09-30 2019-09-30 2019-09-30 Last Shipments 2019-12-31 2019-12-31 2019-12-31 2019-12-31 2019-12-31 2019-12-31 Please contact your nearest TDK sales office if you need support in selecting a suitable substitute. The addresses of our worldwide sales network are presented at www.tdkelectronics.tdk.com/sales. 2-line filters B84142A*R122 for converters and power electronics Power line filters for 1-phase systems Rated voltage VR: 300 V AC/DC Rated current IR: 8 A to 180 A Construction 2-line filters Metal case Features High insertion loss Easy to install Space-saving design Low weight Design complies with IEC 60939 UL and cUL approval Typical applications Power supplies DC applications Terminals Finger-safe terminal blocks Marking Marking on component: Manufacturer's logo, ordering code, rated voltage, rated current, rated temperature, climatic category, date code, approvals Minimum data on packaging: Manufacturer's logo, ordering code, quantity, date code Typical circuit diagram Please read Cautions and warnings and Important notes at the end of this document. Page 2 of 15 2-line filters B84142A*R122 for converters and power electronics Technical data and measuring conditions Rated voltage VR Rated current IR Test voltage Vtest 300 V AC (50/60 Hz) / 300 V DC Referred to 50 °C rated temperature 1700 V DC, 2 s (line/line) 3000 V DC, 2 s (lines/case) 1.5  IR for 3 min per hour or 2.5  IR for 30 s per hour At VR and 50 Hz 25/100/21 (25 °C/+100 °C/21 days damp heat test) UL 1283, CSA C22.2 No.8 Overload capability (thermal) Leakage current lLK Climatic category (IEC 60068-1) Approvals Characteristics and ordering codes IR A Terminal cross section mm2 VR = 300 V AC/DC 8 4 16 4 30 10 42 10 55 10 75 16 100 35 130 50 180 95 ILK Rtyp Ordering code Approvals mΩ Approx. weight kg mA 32 32 32 45 45 45 95 95 95 15 9 5 4 3 1.5 1.1 0.7 0.5 0.7 1.1 1.7 1.9 1.9 2.6 5.0 8.0 8.0 B84142A0008R122 B84142A0016R122 B84142A0030R122 B84142A0042R122 B84142A0055R122 B84142A0075R122 B84142A0100R122 B84142A0130R122 B84142A0180R122 × × × × × × × × × × = Approval granted Please read Cautions and warnings and Important notes at the end of this document. Page 3 of 15 × × × × × × × × × 2-line filters B84142A*R122 for converters and power electronics Dimensional drawings B84142A0008R122 (8 A) General tolerances according to ISO 2768cL Dimensions in mm B84142A0016R122 (16 A) General tolerances according to ISO 2768cL Dimensions in mm Please read Cautions and warnings and Important notes at the end of this document. Page 4 of 15 2-line filters B84142A*R122 for converters and power electronics B84142A0030R122 ... B84142A0055R122 (30 A, 42 A, 55 A) General tolerances according to ISO 2768cL Dimensions in mm B84142A0075R122 (75 A) General tolerances according to ISO 2768cL Dimensions in mm Please read Cautions and warnings and Important notes at the end of this document. Page 5 of 15 2-line filters B84142A*R122 for converters and power electronics B84142A0100R122 (100 A) General tolerances according to ISO 2768cL Dimensions in mm B84142A0130R122 (130 A) General tolerances according to ISO 2768cL Dimensions in mm Please read Cautions and warnings and Important notes at the end of this document. Page 6 of 15 2-line filters B84142A*R122 for converters and power electronics B84142A0180R122 (180 A) General tolerances according to ISO 2768cL Dimensions in mm Please read Cautions and warnings and Important notes at the end of this document. Page 7 of 15 2-line filters B84142A*R122 for converters and power electronics Insertion loss (typical values at Z = 50 Ω) Filters for 8 A Filters for 16 A Filters for 30 A Filters for 42 A Please read Cautions and warnings and Important notes at the end of this document. Page 8 of 15 2-line filters B84142A*R122 for converters and power electronics Insertion loss (typical values at Z = 50 Ω) Filters for 55 A Filters for 75 A Filters for 100 A Filters for 130 A Please read Cautions and warnings and Important notes at the end of this document. Page 9 of 15 2-line filters B84142A*R122 for converters and power electronics Insertion loss (typical values at Z = 50 Ω) Filters for 180 A Please read Cautions and warnings and Important notes at the end of this document. Page 10 of 15 2-line filters B84142A*R122 for converters and power electronics Cautions and warnings Please read all safety and warning notes carefully before installing the EMC filter and putting it into operation (see ). The same applies to the warning signs on the filter. Please ensure that the signs are not removed nor their legibility impaired by external influences. Death, serious bodily injury and substantial material damage to equipment may occur if the appropriate safety measures are not carried out or the warnings in the text are not observed. Using according to the terms The EMC filters may be used only for their intended application within the specified values in lowvoltage networks in compliance with the instructions given in the data sheets and the data book. The conditions at the place of application must comply with all specifications for the filter used. Warning It shall be ensured that only qualified persons (electricity specialists) are engaged on work such as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. Danger of electric shock. EMC filters contain components that store an electric charge. Dangerous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. The protective earth connections shall be the first to be made when the EMC filter is installed and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed. Impermissible overloading of the EMC filter or filter, such as with circuits able to cause resonances, impermissible voltages at higher frequencies etc. can lead to bodily injury and death as well as cause substantial material damages (e.g. destruction of the filter housing). EMC filters and filters must be protected in the application against impermissible exceeding of the rated currents by overcurrent protective circuitry. In case of leakage currents >3.5 mA you shall mount the PE conductor stationary with the required cross section before beginning of operation and save it against disconnecting. For leakage currents IL1) 250 A Instructions Reference chapter (data book), paragraph For operating currents greater than 250 A, we Mounting recommend the PE connection to be set up between instructions, point the feed (filter: line) and output (filter: load) not via the 2 PE terminal bolt in the filter housing. Mounting position Note the mounting position of the filters! It must Mounting always be ensured that natural convection is not instructions, point impaired. 13 Long motor cables Long motor cables cause parasitic currents in the installation. The cable lengths indicated for the output chokes and output filters serve for orientation. The user must check the technical parameters and especially the choke temperatures for the respective application. Mounting instructions, point 15 Display of ordering codes for EPCOS products The ordering code for one and the same product can be represented differently in data sheets, data books, other publications and the website of EPCOS, or in order-related documents such as shipping notes, order confirmations and product labels. The varying representations of the ordering codes are due to different processes employed and do not affect the specifications of the respective products. Detailed information can be found on the Internet under www.epcos.com/orderingcodes Please read Cautions and warnings and Important notes at the end of this document. Page 13 of 15 2-line filters B84142A*R122 for converters and power electronics Symbols and terms Symbol English α Insertion loss CR Rated capacitance CX Capacitance X capacitor CY Capacitance Y capacitor ∆V Voltage drop (input to output) dv/dt Rate of voltage rise f Frequency fM Converter output frequency fP Pulse frequency fR Rated frequency fres Resonant frequency IC Current through capacitor ILK Filter leakage current Imax Maximum current IN Nominal current Iop Operating current (design current) Ipk Rated peak withstand current Iq Capacitive reactive current IR Rated current IS Interference current L Inductance LR Rated inductance Lstray Stray inductance PL Power loss R Resistance Ris Insulation resistance Rtyp DC resistance, typical value TA Ambient temperature Tmax Upper category temperature Tmin Lower category temperature TR Rated temperature uk Refered voltage drop in % Veff RMS voltage VK Voltage drop VLE Voltage line to earth; voltage line to ground VN Nominal voltage VR Rated voltage Vpeak Peak voltage Vtest Test voltage VX Voltage over X capacitor VY Voltage over Y capacitor XL Inductive reactance Z Impedance |Z| Impedance, absolute value Please read Cautions and warnings and Important notes at the end of this document. Page 14 of 15 German Einfügungsdämpfung Bemessungskapazität Kapazität X-Kondensator Kapazität Y-Kondensator Spannungsabfall im Filter Spannungsanstiegsgeschwindigkeit Frequenz Motorfrequenz Pulsfrequenz Bemessungsfrequenz Resonanzfrequenz Strom durch Kondensator Filter-Ableitstrom Maximalstrom Nennstrom Betriebsstrom Bemessungs-Stoßstromfestigkeit Kapazitiver Blindstrom Bemessungsstrom Störstrom Induktivität Bemessungsinduktivität Streuinduktivität Verlustleistung Widerstand Isolationswiderstand Gleichstromwiderstand, Richtwert Umgebungstemperatur Obere Kategorietemperatur Untere Kategorietemperatur Bemessungstemperatur Bezogener Spannungsabfall in % Effektivspannung Spannungsabfall Spannung Phase zu Erdpotential Nennspannung Bemessungsspannung Spitzenspannung Prüfspannung Spannung über X-Kondensator Spannung über Y-Kondensator Induktiver Blindwiderstand Scheinwidertand Scheinwiderstand (Betragswert) Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule we are either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether a product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.tdk-electronics.tdk.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to our General Terms and Conditions of Supply. 7. Our manufacturing sites serving the automotive business apply the IATF 16949 standard. The IATF certifications confirm our compliance with requirements regarding the quality management system in the automotive industry. Referring to customer requirements and customer specific requirements (“CSR”) TDK always has and will continue to have the policy of respecting individual agreements. Even if IATF 16949 may appear to support the acceptance of unilateral requirements, we hereby like to emphasize that only requirements mutually agreed upon can and will be implemented in our Quality Management System. For clarification purposes we like to point out that obligations from IATF 16949 shall only become legally binding if individually agreed upon. 8. The trade names EPCOS, CeraCharge, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CTVS, DeltaCap, DigiSiMic, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell, MKD, MKK, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PowerHap, PQSine, PQvar, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.tdk-electronics.tdk.com/trademarks. Release 2018-10 Page 15 of 15
B84142A30R122 价格&库存

很抱歉,暂时无法提供与“B84142A30R122”相匹配的价格&库存,您可以联系我们找货

免费人工找货