FCPS-24FE

FCPS-24FE

  • 厂商:

    ETC1

  • 封装:

  • 描述:

    FCPS-24FE - 24 Volt, 6 Amp Remote Power Supply - List of Unclassifed Manufacturers

  • 数据手册
  • 价格&库存
FCPS-24FE 数据手册
July13, 2004 DF-51401 •D-100 Volt, Remote Power 24 Volt, 6 Amp Remote Power Supply www.firelite.com Section: Power Supplies/Accessories FCPS-24F(E) FCPS-24F(E) GENERAL The Fire•Lite FCPS-24F(E) is a compact, cost-effective, 6amp remote power supply with battery charger. The FCPS24F(E) may be connected to any 12- or 24-volt Fire Alarm Control Panel (FACP) or may stand alone. Primary applications include Notification Appliance (bell) Circuit (NAC) expansion (to support ADA requirements) or auxiliary power to support 24-volt system accessories. The FCPS provides regulated and filtered 24 VDC power to four Notification Appliance Circuits (two Class A [Style Z] and two Class B [Style Y] or four Class B only). Alternately, the four outputs may be configured as any combination of resettable/non-resettable power outputs (optimal for powering four-wire smoke detectors). The FCPS-24F(E) also contains a battery charger capable of charging up to 7.0 Amp Hour batteries. CS868 California State Fire Marshal 7315-0075:176 (FCPS-24F) (FCPS-24F FCPS-24FE) S2424 S1287 (FCPS-24F) MEA (FCPS-24F) 387-94-E FEATURES FEATURES • Requires input trigger voltage of 9.0 - 32 VDC. • Contains two, fully-isolated input/control circuits (triggered from FACP Notification Appliance Circuit [NAC expander mode] or jumpered permanently on [standalone mode]). • Two Class A (Style Z) or Class B (Style Y) Notification Appliance Circuits (circuits 1 & 3). • Two additional NACs that may be individually configured for Class B (Style Y) operation only (circuits 2 & 4). • 6 Amp full load output (3 amps max./ckt.) in NAC expander mode (UL 864). • 4 Amp continuous output in stand-alone mode (UL 1481). • In stand-alone mode, output power circuits may be configured as resettable (reset line from FACP required) or non-resettable. • Fully regulated and filtered power output (optimal for powering four-wire smoke detectors, annunciators and other system peripherals requiring regulated/filtered power). • Fuseless, power-limited technology meets new UL powerlimiting requirements, effective May 1, 1995. • Normally closed trouble contact. • Fully supervised power supply, battery and Notification Appliance Circuits. • Selectable earth fault detection. • AC trouble report selectable for immediate, 8 or 16 hour delay. • Optional ammeter/voltmeter. • Works with virtually any UL 864 fire alarm control which utilizes an industry-standard reverse-polarity notification circuit. • Self-contained in compact, lockable cabinet (15" [381 mm] H x 14.5" [368 mm] W x 2.75" [70 mm] D). • Includes integral battery charger capable of charging up to 7.0 AH batteries. • Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.25 mm²) wire. STAND ANDARDS STANDARDS and CODES The FCPS-24F complies with the following standards: • NFPA 72 National Fire Alarm Code. • UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). • UL 1481 P ower Supplies for Fire Alarm Systems (stand-alone mode). Fire•Lite® Alarms is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms , One Fire-Lite Place, Northford, Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. DF-51401 • 07/13/04 — Page 1 of 3 SPECIFICATIONS SPECIFICATIONS Primary (AC) Power • FCPS-24F: 120 VAC 50/60 Hz, 2.0 A max. • FCPS-24FE: 220/240 VAC 50/60 Hz, 1.0 A max. • Wire size: minimum #14 AWG (2.0 mm²) with 600V insulation. Control Input Circuit • Trigger Input Voltage: 9.0 to 32 VDC. • Trigger Current: 2.0 mA (16 - 32 V). (per input) 1.0 mA (9 - 16 V). Trouble Contact Rating • 5 amps at 24 VDC. Auxiliary Power Output • Specific Application Power - 45 mA Short Circuit. Output Circuits • +24 VDC (19.1 - 26.4) filtered, regulated. • 3.0 amps maximum for any one circuit. • 4.0 amps maximum total continuous current for all outputs (Stand-alone mode). • 6.0 amps maximum total short-term current for all outputs (NAC Expander mode). Secondary Power (Battery) Charging Circuit • Supports lead acid batteries only. • Float Charge Voltage: 27.6V. • Maximum Charge Current: 250 mA. • Maximum Battery Capacity: 7.0 AH. DESIGNATIONS TERMINAL DESIGNATIONS Notes: 1) Cut JP1 to use a UL listed external battery charger, or MPM-4F ammeter/ voltmeter. 2) Cut R134 to delay AC loss reporting for 8 hours (24-hour standby), or cut R134 and R76 to delay AC loss reporting 16 hours (60-hour standby). 3) Cut R175 to make output #2 nonresettable in stand-alone mode. 4) Cut R176 to make output #4 nonresettable in stand-alone mode. INFORMATION ORDERING INFORMATION FCPS-24F Remote charger power supply (120 VAC). Includes main printed circuit board, transformers, red enclosure, and installation instructions. Remote charger power supply (220/240 VAC). Includes main printed circuit board, transformers, red enclosure, and installation instructions. MPM-4F A77-716B BAT-1270 MPM-4F FCPS-24FE 12/24 VDC end-of-line relay for monitoring 4-wire smoke detector power. Battery, 12 volt, 7.0 AH (two required). Optional ammeter/voltmeter. Mounts in FCPS backbox. Page 2 of 3 — DF-51401• 07/13/04 Application Examples Example 1.0: Expand notification appliance power an additional 6.0 amps. Use up to 4 Class B (Style Y) outputs or 2 Class A (Style Z) and 2 Class B (Style Y) outputs. In this example, the FACP notification appliance circuits will activate the FCPS-24F(E) when reverse polarity activation occurs. Trouble conditions on the FCPS-24F(E) are sensed by the FACP through Notification Appliance Circuit #1. Example 2.0: Use the FCPS-24F(E) to expand auxiliary regulated 24 volt system power up to 4 amps. Both non-resettable and resettable power options are available. Resettable outputs are created by connecting the resettable output from the FACP to one or both of the FCPS24F(E) inputs. Non-resettable outputs are created simply by cutting on board resistors. For addressable panel applications, use a monitor module to sense the trouble status of the FCPS-24F(E) via the trouble relay contacts. Example 3.0: Use addressable control modules to activate the FCPS-24F(E) versus the FACP Notification Appliance Circuits. This typically allows for mounting the FCPS-24F(E) at greater distances* away from the FACP while expanding system architecture in various applications. In this example, an addressable control module is used to activate the FCPS-24F(E) and an addressable monitor module is used to sense FCPS-24F(E) trouble conditions. Local auxiliary power output from the FCPS-24F(E) provides power to the addressable control module. *The Fire•Lite MS-9200, 198-point Addressable FACP has the capability of locating control and monitor modules up to 10,000 feet away. DF-51401 • 07/13/04 — Page 3 of 3
FCPS-24FE 价格&库存

很抱歉,暂时无法提供与“FCPS-24FE”相匹配的价格&库存,您可以联系我们找货

免费人工找货