0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
C211220060

C211220060

  • 厂商:

    ETC2

  • 封装:

  • 描述:

    C211220060 - Timers Symmetrical Recycler - List of Unclassifed Manufacturers

  • 数据手册
  • 价格&库存
C211220060 数据手册
Timers Symmetrical Recycler Types C 101, C 201, C 108, C 208, C 111, C 211, C 118, C 218 • Time ranges: 0.15 s to 600 s • Automatic start • C .0.: Starts with OFF-time C .1.: Starts with ON-time • Knob-adjustable time within range • Oscillator-controlled time circuit • Repeatability deviation: ≤ 1% • Output: 10 A SPDT or 8 A DPDT relay • Plug-in type module • Scantimer housing • LED-indication for relay on • AC or DC power supply Product Description Mono-function, plug-in, symmetrical, ON/OFF miniature recyclers up to 600 s (10 min) covering 3 individual time ranges. Optional ON- or OFFtime period first. This economical relay is often used in lighting systems such as advertising signs, etc. Ordering Key Function Output Type Power supply Time range C 108 024 600 Type Selection, OFF-Time Period First Plug Circular 8 pin Circular 11 pin Circular 8 pin Circular 11 pin DPDT Output SPDT Time ranges 0.15- 6 s 1.5 - 60 s 15 - 600 s 0.15- 6 s 1.5 - 60 s 15 - 600 s 0.15- 6 s 1.5 - 60 s 15 - 600 s 0.15- 6 s 1.5 - 60 s 15 - 600 s Supply: 24 VAC/DC C 108 024 006 C 108 024 060 C 108 024 600 C 101 024 006 C 101 024 060 C 101 024 600 C 208 024 006 C 208 024 060 C 208 024 600 C 201 024 006 C 201 024 060 C 201 024 600 Supply: 120 VAC C 108 120 006 C 108 120 060 C 108 120 600 C 101 120 006 C 101 120 060 C 101 120 600 C 208 120 006 C 208 120 060 C 208 120 600 C 201 120 006 C 201 120 060 C 201 120 600 Supply: 220 VAC C 108 220 006 C 108 220 060 C 108 220 600 C 101 220 006 C 101 220 060 C 101 220 600 C 208 220 006 C 208 220 060 C 208 220 600 C 201 220 006 C 201 220 060 C 201 220 600 Type Selection, ON-Time Period First Plug Circular 8 pin Circular 11 pin Circular 8 pin Circular 11 pin DPDT Output SPDT Time ranges 0.15- 6 s 1.5 - 60 s 15 - 600 s 0.15- 6 s 1.5 - 60 s 15 - 600 s 0.15- 6 s 1.5 - 60 s 15 - 600 s 0.15- 6 s 1.5 - 60 s 15 - 600 s Supply: 24 VAC/DC C 118 024 006 C 118 024 060 C 118 024 600 C 111 024 006 C 111 024 060 C 111 024 600 C 218 024 006 C 218 024 060 C 218 024 600 C 211 024 006 C 211 024 060 C 211 024 600 Supply: 120 VAC C 118 120 006 C 118 120 060 C 118 120 600 C 111 120 006 C 111 120 060 C 111 120 600 C 218 120 006 C 218 120 060 C 218 120 600 C 211 120 006 C 211 120 060 C 211 120 600 Supply: 220 VAC C 118 220 006 C 118 220 060 C 118 220 600 C 111 220 006 C 111 220 060 C 111 220 600 C 218 220 006 C 218 220 060 C 218 220 600 C 211 220 006 C 211 220 060 C 211 220 600 Specifications are subject to change without notice (25.10.99) 1 C 108, C 208, C 118, C 218 C 101, C 201, C 111, C 211 Time Specifications Time ranges 0.15- 6 s 1.5 - 60 s 15.0 - 600 s 0 to +10% on max. min. actual time ≤ min. set time Repeatability deviation Time variation Within rated power supply and ambient temperature Reset Time and/or relay ≤ 1% ≤ 0.05%/V ≤ 0.2%/°C Power supply interruption min. 250 ms Time range accuracy Output Specifications C 108, C 101, C 118, C 111 Output Basic electrical insulation Contact ratings (AgCdO) Resistive loads AC 1 DC 1 or Small inductive loads AC 15 DC 13 Mechanical life Electrical life AC 1 Operating frequency Insulation voltages Rated insulation voltage Rated transient protection volt. SPDT relay 250 VAC (rms) (contact/electronics) µ (micro gap) 10 A/250 VAC (2500 VA) 1 A/250 VDC (250 W) 10 A/25 VDC (250 W) 2.5 A/230 VAC 5 A/24 VDC ≥ 30 x 106 operations ≥ 2.5 x 105 operations (at max. load) ≤ 7200 operations/h ≥ 2.0 kVAC (rms) (contact/electronics) 4 kV (1.2/50 µs) (contact/electronics) (IEC 60664) C 208, C 201, C 218, C 211 DPDT relay 250 VAC (rms) (contacts/elec., contact/contact) µ (micro gap) 8 A/250 VAC (2000 VA) 0.4 A/250 VDC (100 W) 4 A/25 VDC (100 W) 2.5 A/230 VAC 5 A/24 VDC ≥ 30 x 106 operations ≥ 2.5 x 105 operations (at max. load) ≤ 7200 operations/h ≥ 2.0 kVAC (rms) (contact/electronics) 4 kV (1.2/50 µs) (contact/electronics) (IEC 60664) Supply Specifications 220 VAC + 15/- 20%, 45 to 65 Hz 120 VAC + 15/- 20%, 45 to 65 Hz 024 24 VAC + 15/- 20%, 45 to 65 Hz Dropout tolerance ≥ 10 ms Rated insulation voltage None Rated transient protection volt. 4 kV (1.2/50 µs) @ 220 VAC 2.5 kV (1.2/50 µs) @ 120 VAC 800 V (1.2/50 µs) @ 24 VAC (line/neutral) Power supply DC type Installation cat. III (IEC 60664) Rated operational volt. 024 24 VDC + 15/- 20% (pin 2 pos.) Rated insulation voltage Rated transient protection volt. Consumption AC supply DC supply Power ON delay Power OFF delay None 800 V (1.2/50 µs) 60 mA @ 50 Hz/70 mA @ 60 Hz 1W ≤ 200 ms ≥ 250 ms Power supply AC types Rated operational voltage through pins 2 & 10 220 or pins 2 & 7 120 Installation cat. III (IEC 60664) General Specifications Indication for Output ON Environment Degree of protection Pollution degree Operating temperature Storage temperature Weight Approvals LED. red IP 20 B 2 (IEC 60664) -20° to +50°C (-4° to +122°F) -50° to +85°C (-58° to +185°F) 85 g UL, CSA 2 Specifications are subject to change without notice (25.10.99) C 108, C 208, C 118, C 218 C 101, C 201, C 111, C 211 Mode of Operation Example 1 (Types C .0.) OFF-time period first The time period starts when power supply is applied. At the end of the first set time period, the relay operates. At the end of the second set time period (equal to the first), the relay releases. This sequence is repeated until power supply is interrupted. If power supply is disconnected, the time is reset and a recovery period of 250 ms should be allowed before the recycler is ready for reactivation. Example 2 (Types C .1.) ON-time period first The relay operates and the time period starts immediately when power supply is applied. At the end of the first set time period, the relay releases. At the end of the second set time period (equal to the first), the relay operates again. This sequence is repeated with equal intervals until power supply is interrupted. If power supply is interrupted, the time is reset and a recovery period of 250 ms should be allowed before the recycler is ready for reactivation. Wiring Diagrams Power supply C 108, C 118 C 208, C 218 Power supply C 101, C 111 C 201, C 211 Time Setting Knob-adjustable on scale in seconds. Accessories Sockets◊ Hold down spring◊ Mounting rack Socket cover Potentiometer lock S 408, S 411 HF SM 13 BB4 PL 1 For further information refer to "Accessories". Operation Diagram Power supply Example 1: Relay on Example 2: Relay on Specifications are subject to change without notice (25.10.99) 3
C211220060 价格&库存

很抱歉,暂时无法提供与“C211220060”相匹配的价格&库存,您可以联系我们找货

免费人工找货