0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EM3-DINAV93

EM3-DINAV93

  • 厂商:

    ETC2

  • 封装:

  • 描述:

    EM3-DINAV93 - Energy Management Energy Meter with plug-in Output Modules - List of Unclassifed Manuf...

  • 数据手册
  • 价格&库存
EM3-DINAV93 数据手册
Energy Management Energy Meter with plug-in Output Modules Type EM3-DIN • Class 2 (active energy) • Class 3 (reactive energy) • Active reactive energy meter • Direct connection up to 90A • Electromechanical display 6+1DGT • LED for the indication of the consumed energy • Selection of the displayed energy by means of dip-switch • Optional pulse output (as a module) • Self power supply or auxiliary power supply 115VAC, 230VAC 50-60Hz • Full compliance with EN61036 (active energy, class 2) • Full compliance with EN61268 (reactive energy, class 3) • Dimensions: 9 DIN-modules • Sealable housing Product description EM3-DIN is a three-phase energy meter for the measure of active or reactive energy; the 208VL-L, 220VL-L and 400VL-L meters are self-supplied, while the 660VL-L meters are provided with auxiliary power supply. EM3-DIN is provided with: 6+1DGT electromechanical indicator for the indication of kWh or kvarh; one green LED for the indication of power ON; one red LED blinking proportionally to the consumed energy. System 3 : Three-phase, unbalanced load How to order Model Range code System Power supply Slot A EM3-DIN AV9 3 X X Type selection Range code Auxiliary Power Supply (C or D): AV3: 660VL-L / 20(90)AAC Self Power Supply (X): AV2: 220VL-L / 20(90)AAC AV8: 208VL-L / 20(90)AAC AV9: 400VL-L / 20(90)AAC Important note: the AV2 model is suitable only for three-phase unbalanced system without neutral. Power supply C: 115VAC - 15+10% 50-60Hz (only range AV3) D: 230VAC -15+10% 50-60Hz (only range AV3) X: Self power-supply Slot A (retransmission) X: O: R: None Module AO2900 Dual open collector pulse output Module AO2910 One relay output + one open collector output. Input specifications Accuracy Active energy Reactive energy Start-up current Additional errors Voltage variation Frequency variation Wave form Voltage disymmetry External continuous magnetic induction Magnetic induction HF electromagnetic field Accessories influence Temperature drift Measurements Wave form Crest factor (I ≤ 20A) Basic current (Ib) Maximum current (Imax) Overload Continuous: current For 10ms: current Class 2, according to EN61036 Class 3, according to EN61268 80mA Acc. to EN61036, EN61268 < 0.5% < 0.5% 720kΩ (220VL-L), ≤ 4VA > 1.97MΩ (660VL-L), ≤ 4VA > 720KΩ (208VL-L), ≤ 4VA > 720KΩ (400VL-L), ≤ 4VA 50-60 Hz 3-phase, unbalanced with or without neutral. Note: in the self-supplied version, the neutral must be connected to the measuring inputs. Electromechanical type 6+1 DGT Green LED, ON if supplied Red LED, 640 imp./kWh/ kvarh (min. period: 0.5s) By means of DIP-switch ON: active energy OFF: reactive energy Display Power supply Energy consumption Selection of displayed energy Dip-switch 1 Specifications are subject to change without notice EM3-DINDS240806 1 EM3-DIN Output specifications Pulse outputs (on request) Number of outputs AO2900, slot A 2 Pulse outputs to be used as retransmission of the energies: active energy reactive energy 10 / kWh, 10 / kvarh Open collector (NPN transistor) VON 1.2VDC / max 100mA VOFF 30VDC max 220ms (ON), ≥200ms (OFF) according to DIN43864 ≤10µA, @ 30V, 60°C By means of optocouplers, 2000Vrms for 1 minute between measuring inputs and pulse outputs. AO2910 module Pulse output Output type Insulation Insulation between the two outputs: functional Relay + open collector output. Working mode like AO2900. One static output+one relay output, other characteristics like AO2900. Static type like module AO2900; Relay type: SPDT, AC1, AC15: 1AAC @250VAC 2000 VRMS outputs to measuring inputs, 2000 VRMS output to supply input. Insulation between the two outputs: 2000 VRMS Channel 1 Channel 2 Number of pulses Type Pulse duration Leakage current Insulation Power supply specifications Self power supply 400VAC VL-L -20% +15% 50-60Hz 208VAC VL-L -20% +15% 50-60Hz 220VAC VL-L -10+15%, 50-60Hz Auxiliary power supply 230VAC -15+10% 50-60Hz 115VAC -15+10% 50-60Hz General specifications Operating temperature -20 to +55°C (14°F to 131°F) (R.H. from 0 to 90% non-condensing @ 40°C) Storage temperature Dielectric strength Installation category EMC Burst Immunity to irradiated electromagnetic fields Electrostatic discharges Radio frequency emissions Pulse voltage (1.2/50µs) according to EN61036 and EN61268 -20 to +70°C (14°F to 140°F) 4000Vrms for 1 minute Cat. lll (IEC 664) 4kV / level 4 (EN61000-4-4) 10V/m from 26 to 1000MHz (EN61000-4-3) 15kV (EN61000-4-2) according to CISPR 14 and CISPR 22 8kV (EN61000-4-5) Standards Metrology Safety Pulse output Connections Cable cross-section area EN61036, EN61268 IEC-664 DIN 43864 Screw-type, Max. 35 mm2 (measuring inputs) Min. 6 mm2 (measuring inputs) Other inputs: 4 mm2 Min./Max. screws tightening torque 2 Nm / 6 Nm (90A inputs) Housing Dimensions 162.5 x 90 x 63 mm Material ABS, NORYL, PC self-extinguishing Mounting DIN-rail or wall Degree of protection Front: IP40 Screw terminals: IP20 Weight Approx. 800 g (packing included) Available models and modules Type EM3-DIN AV9.3.X EM3-DIN AV8.3.X EM3-DIN AV2.3.X EM3-DIN AV3.3.C EM3-DIN AV3.3.D Open collector output Relay + open coll. output 2 Inputs 400VL-L / 20(90)AAC 208VL-L / 20(90)AAC 220VL-L / 20(90)AAC 660VL-L / 20(90)AAC 660VL-L / 20(90)AAC Power Supply Self power supply Self power supply Self power supply 115VAC - 15+10% 230VAC - 15+10% Number of channels 2 2 Specifications are subject to change without notice Ordering code AE2000 AE2001 AE2004 AE2002 AE2003 AO2900 AO2910 EM3-DINDS240806 EM3-DIN Wiring diagrams EM3-DIN 20(90)A Self power-supplied Fig. 1 Auxiliary power-supply Fig. 2 Auxiliary power-supply Fig. 3 Direct connection (3-phase system + N) Direct connection (3-phase system) Direct connection (3-phase system + N) Wiring diagrams (optional module) Open collector output Fig. 1 Relay + open collecttor output Fig. 2 Only open collector outputs: the grounds of the outputs are separated, and therefore it’s possible to carry out, for the same module, two different connections. The load resistance (Rc) must be designed so that the closed contact current is lower than 100mA; the VDC voltage must be lower than or equal to 30V. Accuracy Accuracy (RDG) depending on the current +4% +2.5% Accuracy (RDG) depending on the current +5% +4% Error Error +2% 0% -2% -2.5% +3% 0% -3% -4% -4% 1A (0.05 Ib) 2A (0.1) Ib 20A (Ib) 90A (Imax) -5% 1A (0.05 Ib) 2A (0.1) Ib 20A (Ib) 90A (Imax) EN 61036/ IEC 61036 limits Active energy Start-up current: 80mA Specifications are subject to change without notice EM3-DINDS240806 EN 61268/ IEC 61268 limits Reactive energy Start-up current: 80mA 3 EM3-DIN Front panel description 1. Red LED Indicates the consumed energy (640 pulses / kWh, minimum period 0.5ms) blinking proportionally. 2. Green LED Indicates power ON. 3. Display Electromechanical type, 6+1 DGT, displays kWh or kvarh according to the selection made by means of an internal dip-switch. 4. Engineering unit Removable double sided [front (kWh) / back (kvarh)] label 3 1 2 4 Dimensions Terminal board Dual open collector output module Realy + open collecttor output AO 2900 AO 2910 Specifications are subject to change without notice EM3-DINDS240806 4
EM3-DINAV93 价格&库存

很抱歉,暂时无法提供与“EM3-DINAV93”相匹配的价格&库存,您可以联系我们找货

免费人工找货