0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
OM1915NTM

OM1915NTM

  • 厂商:

    ETC2

  • 封装:

  • 描述:

    OM1915NTM - ISOLATED HERMETIC FIXED VOLTAGE NEGATIVE REGULATORS APPROVED TO DESC DRAWINGS - List of ...

  • 数据手册
  • 价格&库存
OM1915NTM 数据手册
OM1905STM OM1912STM OM1915STM OM1905NTM OM1912NTM OM1915NTM ISOLATED HERMETIC FIXED VOLTAGE NEGATIVE REGULATORS APPROVED TO DESC DRAWINGS Three Terminal, Fixed Voltage, 1.5 Amp Precision Negative Regulators In Hermetic JEDEC TO-257AA Package FEATURES • • • • • • • Isolated Hermetic Package, JEDEC TO-257AA Outline Output Voltages: -5V, -12V, -15V Output Voltages Set Internally to ±1% Built-In Thermal Overload Protection Short Circuit Current Limiting Product Is Also Available In Non-Isolated Package Similar To Industry Standards 7905, 7912, 7915 DESCRIPTION These three terminal negative regulators are supplied in a hermetically sealed metall package whose outline is similar to the industry standard TO-220 plastic package. All protective features are designed into the circuit, including thermal shutdown, current limiting and safe-area control. With heat sinking, they can deliver over 1.5 amps of output current. These units feature internally trimmed output voltages to ±1% of nominal voltage. Standard voltages are -5V, -12V, -15V. These units are ideally suited for Military applications where a hermetically sealed package is required. PART NUMBER DESIGNATOR Standard Military Drawing Number Omnirel Part Number 5962-8874601 UX OM1905STM 5962-8874601 TX OM1905NTM 5962-8874701 UX OM1912STM 5962-8874701 TX OM1912NTM 5962-8874801 UX OM1915STM 5962-8874801 TX OM1915NTM “U” = Isolated “T” = Non-Isolated 3.3 4 11 R2 Supersedes 1 07 R1 3.3 - 93 OM1905STM/NTM - OM1915STM/NTM ABSOLUTE MAXIMUM RATINGS @ 25°C Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -35 V Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . .- 55°C to + 150°C Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C Typical Power/Thermal Charateristics: Rated Power @ 25° C TC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15W TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3W Thermal Resistance qJC (Case U) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2°C/W qJC (Case T) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5°C/W aa qJA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42°C/W ELECTRICAL CHARACTERISTICS -5 Volt Parameter Output Voltage Symbol VOUT VIN = -10V, Io = 500mA, -55°C TA 125°C (unless otherwise specified) Min. -4.95 Max. -5.05 -5.15 Unit V V Test Conditions TA = 25°C VIN = -7.5V to -20V IO = 5mA to 1.0, A, P < 15W • -4.85 Line Regulation (Note 1) (Note 4) VRLINE VIN = -7.5V to -20V 12 mV mV mV mV mV mV mV mV mA mA mA • VIN = -8.0V to -12V 25 5 • Load Regulation (Note 1) IO = 250mA to 750 mA VRLOAD IO = 5mA to 1.5 Amp 12 20 • • 25 15 30 2.5 Standby Current Drain ISCD DISCD (Line) DISCD (Load) VDO IO (pk) IDS DVIN DVOUT NO DVOUT Dt DVOUT = 100mV, IO = 1.0A TA = 25°C VIN = -35V IO = 5mA to 1000mA VIN = -7.0V to -20V Standby Current Drain Change With Line Standby Current Drain Change With Load Dropout Voltage Peak Output Current Short Circuit Current (Note 2) • • • • 1.5 3.0 0.4 0.4 mA 2.5 3.3 1.2 V A A A dB dB • f =120 Hz, DVIN = -10V (Note 3) TA = 25°C, f =10 Hz to 100KHz TA = 25°C, t = 1000 hrs. 63 2.8 3.3 Ripple Rejection • 60 40 Output Noise Voltage (Note 3) Long Term Stability (Note 3) µV/V RMS 75 mV Notes: 1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately. 2. Short Circuit protection is only assured up to VIN = -35V. 3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range. 3.3 - 94 OM1905STM/NTM - OM1915NTM/STM ELECTRICAL CHARACTERISTICS -12 Volt Parameter Output Voltage Symbol VOUT VIN = -19V, Io = 500mA, -55°C TA 125°C (unless otherwise specified) Min. -11.88 Max. -12.12 -12.36 Unit V V Test Conditions TA = 25°C VIN = -14.5V to -27V IO = 5mA to 1.0 A, P < 15W Line Regulation (Note 1) (Note 4) VIN = -16V to -22V VRLINE VIN = -14.5V to -27V 20 mV mV mV mV mV mV mV mV mA mA mA • -11.64 • • 50 10 30 32 Load Regulation (Note 1) VRLOAD IO = 5mA to 1.5 Amp • IO = 250mA to 750 mA 60 16 • Standby Current Drain ISCD DISCD (Line) DISCD (Load) VDO IO (pk) IDS DVIN DVOUT Output Noise Voltage (Note 3) Long Term Stability (Note 3) DVOUT Dt TA = 25°C, t = 1000 hrs. NO DVOUT = 100mV, IO = 1.0A TA = 25°C, IO = 5mA to 1A VIN = -35V IO = 5mA to 1000mA VIN = -14.5V to -27V 30 3.5 Standby Current Drain Change With Line Standby Current Drain Change With Load Dropout Voltage Peak Output Current Short Circuit Current (Note 2) Ripple Rejection • • • • 1.5 4.0 0.8 0.5 mA 1.8 3.3 1.2 V A A A dB dB • f =120 Hz, DVIN = -10V (Note 3) TA = 25°C, f =10 Hz to 100KHz 56 2.8 • 53 40 µV/V RMS 120 mV Notes: 1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately. 2. Short Circuit protection is only assured up to VIN = -35V. 3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range. 4. Minimum load current for full line regulation = 5 mA. MECHANICAL OUTLINE .420 .410 .200 .190 .045 .035 .665 .645 .537 .527 .430 .410 .038 MAX. CONNECTION DIAGRAM 3.3 4 .150 .140 .750 .500 .005 Case U 1 Ground 2 Input 3 Output 4 No Connection 1 2 3 Case T 1 Ground 2 Input 3 Output 4 Input .035 .025 .100 TYP. .120 TYP. 3.3 - 95 OM1905STM/NTM - OM1915STM/NTM ELECTRICAL CHARACTERISTICS -15 Volt Parameter Output Voltage Symbol VOUT VIN = -23V, Io = 500mA, -55°C TA 125°C (unless otherwise specified) Min. -14.85 Max. -15.15 -15.45 Unit V V Test Conditions TA = 25°C VIN = -17.5V to -30V IO = 5mA to 1.0 A, P < 15 W • -14.55 Line Regulation (Note 1) (Note 4) VRLINE VIN = -17.5V to -30V 25 mV mV mV mV mV mV mV mV mA mA mA • VIN = -20V to -26V 50 15 • Load Regulation (Note 1) IO = 250mA to 750 mA VRLOAD IO = 5mA to 1.5 Amp 25 35 • • 75 21 45 6.0 Standby Current Drain ISCD DISCD (Line) DISCD (Load) VDO IO (pk) IDS DVIN DVOUT NO DVOUT Dt DVOUT = 100mV, IO = 1.0A TA = 25°C VIN = -35V IO = 5mA to 1000 mA VIN = -17.5V to -30V Standby Current Drain Change With Line Standby Current Drain Change With Load Dropout Voltage Peak Output Current Short Circuit Current (Note 2) Ripple Rejection • • • • 1.5 6.5 0.8 0.5 mA 2.5 3.3 1.2 V A A A dB dB • f =120 Hz, DVIN = -10V (Note 3) TA = 25°C, f =10 Hz to 100KHz TA = 25°C, t = 1000 hrs. 53 2.8 • 50 40 Output Noise Voltage (Note 3) Long Term Stability (Note 3) µV/V RMS 150 mV Notes: 1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately. 2. Short Circuit protection is only assured up to VIN = -35V. 3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range. TYPICAL PERFORMANCE CHARACTERISTICS PEAK OUTPUT 3.3 3.5 3 Tj = -55°C DROPOUT VOLTAGE 2.5 100 RIPPLE REJECTION 2 Output Current (A) Output Current (A) 2.5 2 Tj = 25°C 1.5 IOUT = 500mA Ripple Rejection (dB) IOUT = 1A 80 VOUT = 5V 60 1.5 1 Tj = 150°C 1 IOUT = 0A 40 VIN - V = 8VDC +3.5Vrms IOUT = 1A Tj = 25°C 0.5 DVOUT = 100MV 0.5 DVOUT = 100mV 20 0 0 5 10 15 20 25 30 35 0 -75 -50 -25 0 25 50 75 100 125 150 0 10 100 1k 10k 100k Input To Output Differential (V) Junction Temperature (°C) Frequency (Hz) 205 Crawford Street, Leominster, MA 01453 USA (508) 534-5776 FAX (508) 537-4246
OM1915NTM 价格&库存

很抱歉,暂时无法提供与“OM1915NTM”相匹配的价格&库存,您可以联系我们找货

免费人工找货