marlow
industries
Subsidiary of II-VI Incorporated
a global leader in thermoelectric solutions
Thermoelectric Cooler SP2503
Performance Values
Hot Side Temperature (°C) Δ Tmax (°C-dry N2): Qmax (watts): Imax (amps): Vmax (vdc): AC Resistance (ohms): 27°C 62.0 21.3 9.36 3.48 0.323 50°C 70.6 23.6 9.24 3.88 ---
RoHS 2002/95/EC Compliant
Mechanical Characteristics
ACR VALUE
.XXX
NUMBER CODE
Marlow Industries, Inc. R SP 2503 XXXXXX
+
POSITIVE LEAD (RED)
.XXX
NUMBER CODE
1.000 [25.40]
Marlow Industries, Inc. R SP 2503 XXXXXX
LEADWIRES- 20 AWG, 19/32 STRANDING TEFLON INSULATED NEGATIVE LEAD (BLACK)
_
+
POSITIVE LEAD (RED) LEADWIRES- 20 AWG, 19/32 STRANDING TEFLON INSULATED NEGATIVE LEAD (BLACK)
1.000 [25.40] 1.130 [28.70] COLD SIDE, Tc
4.0±.5 [101.60±12.70]
_
4.0±.5 [101.60±12.70] .002[0.05] A .001[0.03]
.192±0.0005 [4.88±0.01] .001[0.03] HOT SIDE, Th
Dimensions in [ ] are millimeters Ceramic Material: Alumina (AC)
Dimensions in [ ] are millimeters Ceramic Material: Alumina (AC)
LEAD WIRE CONFIGURATION -04AC ONLY
Ordering Options
Model Number SP2503-03AC Description With 4” Leadwire, ACR Marked and Number Coded With 4” Leadwire, Special Orientation No Leadwires No Leadwires, ACR Marked and Number Coded
SP2503-04AC
SP2503-06AC
SP2503-08AC
BINNING CHART Zone ACR @ 23°C 1 .280 - .282 2 .282 - .286 3 .286 - .290 4 .290 - .294 5 .294 - .298 6 .298 - .302 7 .302 - .306 8 .306 - .310 9 .310 - .314 10 .314 - .318 11 .318 - .322 12 .322 - .326 13 .326 - .330 14 .330 - .334 15 .334 - .338 16 .338 - .342 17 .342 - .346 18 .346 - .350 19 .350 - .354 20 .354 - .357
Features
• • • • • • • RoHS 2002/95/EC compliant Designed for thermal cycling applications Rugged construction Porched configuration for enhanced leadwire strength Leadwires attached with 218°C solder Rated operating temperature of 130°C Height tolerance of ± 0.0005 in. (± 0.01 mm) allows for multiple module applications Modules with number coded ACR bin ranges available. See binning chart..
214-340-4900 (tel) ● 214-341-5212 (fax) ● www.marlow.com
Doc # 102-0313
Rev 2
Page 1 of 2
marlow
Performance Curves
industries
Subsidiary of II-VI Incorporated
a global leader in thermoelectric solutions
Environment: One atmosphere dry nitrogen
Hot Side Temperature: 27°C
Hot Side Temperature: 50°C
HEAT LOAD (WATTS) 0.00 2.50 5.00 7.50 10.0 12.5 15.0 17.5 20.0
80.0
60.0 T (C)
40.0
20.0
0.0
HEAT LOAD (WATTS) 0.00 2.50 5.00 7.50 10.0 12.5 15.0 17.5 20.0
80.0
60.0 T (C) VOLTAGE (VDC)
40.0
20.0
0.0 4.0 3.0 2.0 1.0 0.0 0.0
VOLTAGE (VDC)
3.0
2.0
1.0
Q=0 T=0
Q=0 T=0
0.0 0.0
2.0
4.0 6.0 8.0 CURRENT (AMPS)
10.0
12.0
2.0
4.0 6.0 8.0 CURRENT (AMPS)
10.0
12.0
For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, consult one of our Applications Engineers.
Installation
Recommended mounting methods: Bonding with thermal epoxy, mounting in compression with either thermal grease or flexible graphite products. For additional information, please refer to our TEC Installation Guide.
Operation Cautions
For maximum reliability, storage and operation below 85°C in a non-condensing environment is recommended. To minimize thermal stress, use linear/proportional temperature control or a similar method rather than an ON/OFF method.
Addresses
Marlow Industries, Inc. 10451 Vista Park Road Dallas Texas 75238-1645 214-340-4900 (tel) 214-341-5212 (fax) www.marlow.com Marlow Industries Europe Aberdeen House, South Road Haywards Heath West Sussex RH164NG UK +44 (0)1444-443404 (tel) +44 (0)1444-443334(fax) Marlow Industries Japan 1-1-8-401 Uehara, Shibuya-ku Tokyo, Japan 151-0064 +81 (3) 5454-5280 (tel) +81 (3) 5454-5281(fax)
214-340-4900 (tel) ● 214-341-5212 (fax) ● www.marlow.com
Doc # 102-0313
Rev 2
Page 2 of 2
很抱歉,暂时无法提供与“SP2503”相匹配的价格&库存,您可以联系我们找货