0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EMA-MB91F467S-LS-176M07

EMA-MB91F467S-LS-176M07

  • 厂商:

    CYPRESS(赛普拉斯)

  • 封装:

  • 描述:

    IC MICROCONTROLLER

  • 数据手册
  • 价格&库存
EMA-MB91F467S-LS-176M07 数据手册
Fujitsu Microelectronics Europe User Guide FMEMCU-UG-910070-17 FR60 FAMILY SOCKET ADAPTER BOARD EMA-MB91F467S-LS-176M07 USER GUIDE EMA-MB91F467S-LS-176M07 Revision History Revision History Date 20.12.2007 14.01.2008 14.01.2008 15.01.2008 07.04.2008 13.10.2008 16.01.2009 17.03.2009 Issue V1.0, MB,AW,RH First creation V1.1, CPLD code and S401_4 default settings changed V1.2, CPLD code and default settings changed (SDRAM support) V1.3, Fig. 2.1 changed V1.4, China RoHS note added, CPLD code formatted, SDRAM removed V1.5, CEy Changed Figure 2.1, order of CS select switches interchanged, chapter 3.4 rewritten, some minor corrections and improved descriptions V1.6, CEy Description for EMA-MB91FV460B-001 and functional restrictions added V1.7, CEy Corrected numbering in chapter 1.3.2 and added hint regarding existing application note Latest product revision: 1.1 Latest schematic revision: 1.1 Latest PCB revision: 1.0 Latest CPLD revision: 7S18 This document contains 26 pages. FMEMCU-UG-910070-17 © Fujitsu Microelectronics Europe GmbH -2- EMA-MB91F467S-LS-176M07 Warranty and Disclaimer Warranty and Disclaimer To the maximum extent permitted by applicable law, Fujitsu Microelectronics Europe GmbH restricts its warranties and its liability for the EMA-MB91F467S-LS-176M07 Board and all its deliverables (e.g. software include or header files, application examples, target boards, evaluation boards, engineering samples of IC’s etc.), its performance and any consequential damages, on the use of the Product in accordance with (i) the terms of the License Agreement and the Sale and Purchase Agreement under which agreements the Product has been delivered, (ii) the technical descriptions and (iii) all accompanying written materials. In addition, to the maximum extent permitted by applicable law, Fujitsu Microelectronics Europe GmbH disclaims all warranties and liabilities for the performance of the Product and any consequential damages in cases of unauthorised decompiling and/or reverse engineering and/or disassembling. Note, the EMA-MB91F467S-LS-176M07 Board and all its deliverables are intended and must only be used in an evaluation laboratory environment. 1. Fujitsu Microelectronics Europe GmbH warrants that the Product will perform substantially in accordance with the accompanying written materials for a period of 90 days form the date of receipt by the customer. Concerning the hardware components of the Product, Fujitsu Microelectronics Europe GmbH warrants that the Product will be free from defects in material and workmanship under use and service as specified in the accompanying written materials for a duration of 1 year from the date of receipt by the customer. 2. Should a Product turn out to be defect, Fujitsu Microelectronics Europe GmbH´s entire liability and the customer’s exclusive remedy shall be, at Fujitsu Microelectronics Europe GmbH´s sole discretion, either return of the purchase price and the license fee, or replacement of the Product or parts thereof, if the Product is returned to Fujitsu Microelectronics Europe GmbH in original packing and without further defects resulting from the customer’s use or the transport. However, this warranty is excluded if the defect has resulted from an accident not attributable to Fujitsu Microelectronics Europe GmbH, or abuse or misapplication attributable to the customer or any other third party not relating to Fujitsu Microelectronics Europe GmbH. 3. To the maximum extent permitted by applicable law Fujitsu Microelectronics Europe GmbH disclaims all other warranties, whether expressed or implied, in particular, but not limited to, warranties of merchantability and fitness for a particular purpose for which the Product is not designated. 4. To the maximum extent permitted by applicable law, Fujitsu Microelectronics Europe GmbH´s and its supplier’s liability are restricted to intention and gross negligence. NO LIABILITY FOR CONSEQUENTIAL DAMAGES To the maximum extent permitted by applicable law, in no event shall Fujitsu Microelectronics Europe GmbH and its suppliers be liable for any damages whatsoever (including but without limitation, consequential and/or indirect damages for personal injury, assets of substantial value, loss of profits, interruption of business operation, loss of information, or any other monetary or pecuniary loss) arising from the use of the Product. Should one of the above stipulations be or become invalid and/or unenforceable, the remaining stipulations shall stay in full effect © Fujitsu Microelectronics Europe GmbH FMEMCU-UG-910070-17 -3- EMA-MB91F467S-LS-176M07 Contents 0 Contents REVISION HISTORY ............................................................................................................ 2 WARRANTY AND DISCLAIMER ......................................................................................... 3 0 CONTENTS...................................................................................................................... 4 1 OVERVIEW...................................................................................................................... 5 1.1 Abstract................................................................................................................... 5 1.2 General Description................................................................................................. 6 1.3 Functional Restrictions ............................................................................................ 7 2 INSTALLATION ............................................................................................................... 9 3 SWITCHES AND JUMPERS.......................................................................................... 10 3.1 Level Shifter Switches and Jumpers overview....................................................... 10 3.2 Level-shifter direction control jumper ..................................................................... 11 3.3 Bus control jumpers............................................................................................... 12 3.4 Port 17 Jumpers (APIX AIC Link) .......................................................................... 16 3.5 Default Jumper Setting .......................................................................................... 17 4 MECHANICAL DIMENSIONS........................................................................................ 19 5 CPLD ............................................................................................................................. 20 5.1 CPLD Verilog Code ............................................................................................... 20 5.2 CPLD Constraints.................................................................................................. 22 5.3 CPLD programming jumper (J491) ........................................................................ 22 6 INFORMATION IN THE WWW....................................................................................... 23 7 CHINA-ROHS REGULATION ........................................................................................ 24 8 RECYCLING .................................................................................................................. 26 FMEMCU-UG-910070-17 © Fujitsu Microelectronics Europe GmbH -4- EMA-MB91F467S-LS-176M07 Chapter 1: Overview 1 Overview 1.1 Abstract The EMA-MB91F467S-LS-176M07 in combination with the EMA-MB91V460A-002B/-80/003 or EMA-MB91FV460B-001 is a development system for the Fujitsu FR60 MB91V460 Flash microcontroller. The EMA-MB91F467S-LS-176M07 is an adapter board with level shifters to support the MB91V460A external bus interface at 3.3V levels. The development system allows the designer immediately to start with the software development before MB91V460 based silicon samples are available. This board must only be used for test applications in an evaluation laboratory environment. Before using the EMA-MB91F467S-LS-176M07 adapter board, make sure that the following packed components have been delivered: o 1 pcs. EMA-MB91F467S-LS-176M07 socket adapter board o 1 pcs. YQPACK176SD o 5 pcs. Screw M2x12 o 5 pcs. Washer M2, Nylon o 10 pcs. 2mm mini jumper o 1 pcs. User Guide © Fujitsu Microelectronics Europe GmbH FMEMCU-UG-910070-17 -5- EMA-MB91F467S-LS-176M07 Chapter 1: Overview 1.2 General Description The EMA-MB91F467S-LS-176M07 in combination with the EMA-MB91V460A-002B/-80/003 or EMA-MB91FV460B-001 replaces a MB91F467S microcontroller. For further details of the EMA-MB91V460A-002B/-80/003 or EMA-MB91FV460B-001 board please refer to the User Guide of the EMA-MB91V460A-002B/-80/003 or EMA-MB91FV460B-001. In case EMA-MB91V460A-002B/-80/003 is used, the EMA-MB91V460A-300 extension board is required for the emulation of the APIX functionality of MB91F467S. Please refer to the User Guide of the EMA-MB91V460A-300 for further details. In case of EMA-MB91FV460B-001, it is recommended to use EMA-MB91F460S-176M07 as socket adapter board. FMEMCU-UG-910070-17 © Fujitsu Microelectronics Europe GmbH -6- EMA-MB91F467S-LS-176M07 Chapter 1: Overview 1.3 Functional Restrictions 1.3.1 Valid for EMA-MB91V460A-002B/-80/003 This probe cable can only be used for the following Microcontroller configuration: 1. VDD5 = 5V, VDD35 = 3.3V The following Microcontroller configurations (2 & 3) are applicable with this probe cable, but it is recommended to use the appropriate MCU “NLS” probe cable! 2. VDD5 = 5V, VDD35 = 5V 3. VDD5 = 3.3V, VDD35 = 3.3V While using this probe cable, the GPIO functionality on the external bus interface (VDD35 voltage domain) is restricted! Unused external bus function pins (e.g. address lines) cannot be configured as general purpose in- or output randomly! The following ports can be configured as permanent general purpose input OR output. 1. P07[0..7] 2. P06[0..7] 3. P05[0..7] It is only possible to configure the whole port as input OR output! Configuring each pin of these ports separately as input or output is not applicable! For details on how to configure the port input and output direction please see chapter 3.2 Level-shifter direction control jumper! The following pins can be configured as permanent general purpose input OR output separately. 4. P08[0..1], P08_4, P08_7, P09[0..3], P10[0..1], P10_3 It is possible to configure the pins each as input OR output! Configuring each pin of these ports separately as input or output is applicable by removing certain resistors and making appropriate DIP-Switch settings! For details on how to configure the pins input and output direction please see chapter 3.3 Bus control jumpers and the corresponding schematics. APIX functionality must be emulated via external bus access to extension board EMAMB91V460A-300. Please refer also to chapter “Port 17 Jumpers (APIX AIC Link)” for further restrictions. © Fujitsu Microelectronics Europe GmbH FMEMCU-UG-910070-17 -7- EMA-MB91F467S-LS-176M07 Chapter 1: Overview 1.3.2 Valid for EMA-MB91FV460B-001 This probe cable can only be used for the following Microcontroller configuration: 1. VDD5 = 5V, VDD35 = 3.3V The following Microcontroller configurations (2 & 3) are applicable with this probe cable, but it is recommended to use the appropriate MCU “NLS” probe cable! 2. VDD5 = 5V, VDD35 = 5V 3. VDD5 = 3.3V, VDD35 = 3.3V While using this probe cable, the GPIO functionality on the external bus interface (VDD35 voltage domain) is restricted! Unused external bus function pins (e.g. address lines) cannot be configured as general purpose in- or output randomly! The following ports can be configured as permanent general purpose input OR output. 5. P07[0..7] 6. P06[0..7] 7. P05[0..7] It is only possible to configure the whole port as input OR output! Configuring each pin of these ports separately as input or output is not applicable! For details on how to configure the port input and output direction please see chapter 3.2 Level-shifter direction control jumper! The following pins can be configured as permanent general purpose input OR output separately. 8. P08[0..1], P08_4, P08_7, P09[0..3], P10[0..1], P10_3 It is possible to configure the pins each as input OR output! Configuring each pin of these ports separately as input or output is applicable by removing certain resistors and making appropriate DIP-Switch settings! For details on how to configure the pins input and output direction please see chapter 3.3 Bus control jumpers and the corresponding schematics. The routing of SDINM, SDINP, SDOUTM, SDOUTP to the target board is not possible, so you have to use the APIX interface on EMA-MB91FV460B-001. The MCU socket pins 100-103 on your target board will be driven by EMA-MB91FV460B001 with 5V and 1.8V respectively (please see schematic). Check if this is a problem for your target hardware. Ensure that J200-J205 are set to position 2-3! Otherwise the related signals will be driven by EMA-MB91FV460B-001 with various voltages (please see schematic) Set AVCC1 and AVRH1 jumpers on EMA-MB91FV460B-001 so that VDD5 is selected as source. Otherwise these inputs would be supplied by your target board VDD1.8 Please refer also to Application Note mcu-an-300100-e-vxx-ema_mb91f467s_ls_176m07_with_ema_mb91fv460_001 for more information about the limitations and precautions when using EMA-MB91FV460B-001 together with EMA-MB91F467S-LS176M07 FMEMCU-UG-910070-17 © Fujitsu Microelectronics Europe GmbH -8- EMA-MB91F467S-LS-176M07 Chapter 2: Installation 2 Installation Remove carefully the EMA-MB91F467S-LS-176M07 board from the shipping carton and check if there are any damages. Please refer to the attached document “NQPACK/ YQPACK/ HQPACK Technical Information” for installation the socket adapter. Screw M2.5 x 12 (optional) DSU4 SSRAM, Emulation bus Flash + SRAM MB91V460 Washer M2.5 (Fiber) (optional) Connector for extension board EMA-MB91V460A-002B/-80/003 Connector EMA-MB91V460A-002B/-80/003 to EMA-MB91V460A-300 or EMA-MB91F467S-LS-176M07 EMA-MB91V460A-300 (optional) Connector EMA-MB91V460A-002B/-80/003 or EMA-MB91V460A-300 to EMA-MB91F467S-LS-176M07 EMA-MB91F467S-LS-176M07 YQSOCKET176SDN 120,8 mm YQPACK176SD NQPACK / CSPACK NQPACK176SD Target board T Figure 2-1: Installation © Fujitsu Microelectronics Europe GmbH FMEMCU-UG-910070-17 -9- EMA-MB91F467S-LS-176M07 Chapter 3: Switches and Jumpers 3 Switches and Jumpers This chapter describes all switches and jumpers that can be modified or accessed on the EMA-MB91F467S-LS-176M07 board. The default setting is shown with a grey shaded area. 3.1 Level Shifter Switches and Jumpers overview Jumper Description/ Function Type Default S400-1 S400-2 S400-3 S400-4 S400-5 S400-6 S400-7 S400-8 S400-9 S400-10 S401-1 S401-2 S401-3 S401-7 S401-8 S401-9 S400-10 R400 R401 R402 R403 R404 R405 R406 R407 R408 R410 R413 DIR_U406 DIR_U407 DIR_U408 P09_0 CS0# P09_1 CS1# P09_2 CS2# P09_3 CS3# P10_0 SYSCLK P10_1 AS# P10_3 WE# CS select DIP-Switch DIP-Switch DIP-Switch DIP-Switch DIP-Switch DIP-Switch DIP-Switch DIP-Switch DIP-Switch DIP-Switch DIP-Switch DIP-Switch DIP-Switch DIP-Switch DIP-Switch DIP-Switch DIP-Switch 0603 0603 0603 0603 0603 0603 0603 0603 0603 0603 0603 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF Closed Closed Closed Closed Closed Closed Closed Closed Closed Closed Closed P08_7 P08_4 P08_1 P08_0 P09_0 P09_1 P09_2 P09_3 P10_1 P10_3 P08_0 P08_1 P08_4 P08_7 P10_0 RDY RD# WR1 WR0# CS0# CS1# CS2# CS3# AS# WE# WR0# WR1# RD# RDY SYSCLK FMEMCU-UG-910070-17 © Fujitsu Microelectronics Europe GmbH - 10 - EMA-MB91F467S-LS-176M07 Chapter 3: Switches and Jumpers 3.2 Level-shifter direction control jumper Jumper Setting S400-1 (Direction U406) ON Target board A[0..7] MB91V460 A[0..7] OFF Target board A[0..7] MB91V460 A[0..7] ON Target board A[8..15] MB91V460 A[8..15] OFF Target board A[8..15] MB91V460 A[8..15] ON Target board A[16..23] MB91V460 A[16..23] OFF Target board A[16..23] MB91V460 A[16..23] S400-2 (Direction U407) S400-3 (Direction U408) Description Default: S400-1, S400-2, S400-3: OFF © Fujitsu Microelectronics Europe GmbH FMEMCU-UG-910070-17 - 11 - EMA-MB91F467S-LS-176M07 Chapter 3: Switches and Jumpers 3.3 Bus control jumpers 3.3.1 WR0# (P08_0) R406 S400-10 Description Closed OFF MB91V460 P08_0 Target board WR0# Open ON MB91V460 P08_0 Target board WR0# Closed ON Prohibited Default: R406: Closed, S400-10: OFF 3.3.2 WR1# (P08_1) R407 S401-09 Description Closed OFF MB91V460 P08_1 Target board WR1# Open ON MB91V460 P08_1 Target board WR1# Closed ON Prohibited Default: R407: Closed, S401-09: OFF 3.3.3 RD# (P08_4) R408 S401-8 Description Closed OFF MB91V460 P08_4 Target board RD# Open ON MB91V460 P08_4 Target board RD# Closed ON Prohibited Default: R408: Closed, S401-8: OFF 3.3.4 RDY (P08_7) R410 S401-7 Description Closed OFF MB91V460 P08_7 Target board RDY Open ON MB91V460 P08_7 Target board RDY Closed ON Prohibited Default: R410: Closed, S401-7: OFF 3.3.5 CS0# (P09_0) R400 S400-4 Description Closed OFF MB91V460 P09_0 Target board CS0# Open ON MB91V460 P09_0 Target board CS0# Closed ON Prohibited Default: R400: Closed, S400-4: OFF FMEMCU-UG-910070-17 © Fujitsu Microelectronics Europe GmbH - 12 - EMA-MB91F467S-LS-176M07 Chapter 3: Switches and Jumpers 3.3.6 CS1# (P09_1) R401 S400-5 Description Closed OFF MB91V460 P09_1 Target board CS1# Open ON MB91V460 P09_1 Target board CS1# Closed ON Prohibited Default: R401: Closed, S400-5: OFF 3.3.7 CS2# (P09_2) R402 S400-6 Description Closed OFF MB91V460 P09_2 Target board CS2# Open ON MB91V460 P09_2 Target board CS2# Closed ON Prohibited Default: R402: Closed, S400-6: OFF 3.3.8 CS3# (P09_3) R403 S400-7 Description Closed OFF MB91V460 P09_3 Target board CS3# Open ON MB91V460 P09_3 Target board CS3# Closed ON Prohibited Default: R403: Closed, S400-7: OFF 3.3.9 SYSCLK (P10_0) R413 S400-8 Description Closed OFF MB91V460 P10_0 Target board SYSCLK Open ON MB91V460 P10_0 Target board SYSCLK Closed ON Prohibited Default: R413: Closed, S400-8: OFF 3.3.10 AS# (P10_1) R404 S400-9 Description Closed OFF MB91V460 P10_1 Target board AS# Open ON MB91V460 P10_1 Target board AS# Closed ON Prohibited Default: R404: Closed, S400-9: OFF © Fujitsu Microelectronics Europe GmbH FMEMCU-UG-910070-17 - 13 - EMA-MB91F467S-LS-176M07 Chapter 3: Switches and Jumpers 3.3.11 WE# (P10_3) R405 S400-10 Description Closed OFF MB91V460 P10_3 Target board WE# Open ON MB91V460 P10_3 Target board WE# Closed ON Prohibited Default: R405: Closed, S400-10: OFF FMEMCU-UG-910070-17 © Fujitsu Microelectronics Europe GmbH - 14 - EMA-MB91F467S-LS-176M07 Chapter 3: Switches and Jumpers 3.3.12 CS select (CPLD) Chip select signals, selected by S401-1..3, will not be routed towards the target hardware! For applications with extension board EMA-MB91V460A-300 or equivalent extension boards, please select and set the corresponding chip select signal (CSx) used for the extension board! Please also refer to the user guide of the extension board and to the settings on the extension board itself. E.g. EMA-MB91V460A-300 is configured to use chip select CS3, please set S401-1,2,3 on EMA-MB91F467S-LS-176M07 to CS3 (ON, ON, OFF)! In default setting all chip select signals are routed to the target hardware. S401-1 S401-2 S401-3 OFF OFF OFF CS0# is selected ON OFF OFF CS1# is selected OFF ON OFF CS2# is selected ON ON OFF CS3# is selected ON None selected Don’t care Description Default: S401-1, S401-2: OFF, S401-3: ON © Fujitsu Microelectronics Europe GmbH FMEMCU-UG-910070-17 - 15 - EMA-MB91F467S-LS-176M07 Chapter 3: Switches and Jumpers 3.4 Port 17 Jumpers (APIX AIC Link) If EMA-MB91FV460B-001 is used together with EMA-MB91F467S-LS-176M07 set J200J205 to 2-3 and the following mentioned restrictions will not apply! When using EMA-MB91V460A-002B/-80/003 with the EMA-MB91V460A-300 extension board for APIX emulation, it is possible to route the signals from the APIX Automotive Interconnection Link on EMA-MB91V460A-300 to the appropriate pins of the EMAMB91F467S-LS-176M07. Due to wrong pin connections (P17_7 is used as TCLKI on final MB91F467S instead of P17_4) only the Use Cases where one of the data bits acts as the clock signal are supported. Please note: The APIX Automotive Interconnection Link 0 signals of EMA-MB91V460A-300 are routed to APIX Automotive Interconnection Link 1 of EMA-MB91F467S-LS-176M07 3.4.1 P17 / AIC Link function Jumper U100 pin J200 J201 J202 J203 J204 J205 871 86 85 83² 82 81 P 1-2 [AIC Link used] J801_66 (RCK1) J801_69 (RDA10) J801_70 (RDA11) J801_67 (TCKI1) J801_68 (TDA10) J801_65 (TDA11) P 2-3 [P17 function] P17_0 P17_1 P17_2 P17_4 P17_5 P17_6 P 3-4 [AIC Link used] P17_0 pulldown P17_1 pulldown P17_2 pulldown P17_4 pulldown P17_5 pulldown P17_6 pulldown Default: all 2-3 1 Signal available, but corresponding Use Case not supported due to wrong pin assignment of TCLKI1 signal ² TCLKI1 signal available on this pin (P17_4 instead of P17_7) Please refer also to the User Guide of EMA-MB91V460A-300 for the necessary settings on that board. FMEMCU-UG-910070-17 © Fujitsu Microelectronics Europe GmbH - 16 - EMA-MB91F467S-LS-176M07 Chapter 3: Switches and Jumpers 3.5 Default Jumper Setting The following jumper setting is the default setting. Figure 3-1: Jumper default setting, top © Fujitsu Microelectronics Europe GmbH FMEMCU-UG-910070-17 - 17 - EMA-MB91F467S-LS-176M07 Chapter 3: Switches and Jumpers 1 10 S400 ON U100 S401 Figure 3-2: Jumper location, bottom FMEMCU-UG-910070-17 © Fujitsu Microelectronics Europe GmbH - 18 - EMA-MB91F467S-LS-176M07 Chapter 4: Mechanical dimensions 4 Mechanical dimensions Figure 4-1: Mechanical Dimensions © Fujitsu Microelectronics Europe GmbH FMEMCU-UG-910070-17 - 19 - EMA-MB91F467S-LS-176M07 Chapter 5: CPLD 5 CPLD The CPLD Xilinx XC9536XL-5VQL44C controls the direction of the data bus. 5.1 CPLD Verilog Code `timescale 1ns / 1ps /////////////////////////////////////////////////////////////////////////// // Company: Accemic GmbH & Co. KG // Engineer: RH / AW // // Create Date: 05/12/2007 // Design Name: EMA-MB91F467S-LS-176M07 // Module Name: F467S // Project Name: // Target Devices: XC9536XL-5VQ44 // Tool versions: ISE 9.2 // Description: // // Dependencies: // // Revision: // Revision 1.8 // Additional Comments: none // // USERCODE: 7S18 // ||||____ Subversion // |||_____ Version // ||______ Target 467S // ** // /////////////////////////////////////////////////////////////////////////// module EMA_MB91F467S_LS_176M07_V11_cpld_7S18( ECSx, CSx, // P09_7..P09_0 WRx, // P08_3..P08_0 RDx, // P08_4 ASx, // P10_1 BAAx, // P10_2 WEx, // P10_3 IORDx, // P11_0 IOWRx, // P11_1 S401, DIR_U400, DIR_U401, DIR_U404, DIR_U405, OEx_U404, OEx_U405); FMEMCU-UG-910070-17 © Fujitsu Microelectronics Europe GmbH - 20 - EMA-MB91F467S-LS-176M07 Chapter 5: CPLD input ECSx; input[7:0] CSx; input[3:0] WRx; input RDx; input ASx; input BAAx; input WEx; input IORDx; input IOWRx; input[7:1] S401; output DIR_U400; output DIR_U401; output DIR_U404; output DIR_U405; output OEx_U404; output OEx_U405; reg OEx_U404, OEx_U405; reg DIR_U400, DIR_U401, DIR_U404, DIR_U405; always @* begin case (S401[3:1]) // 3'b111: // OEx_U404 3'b110: // OEx_U404 3'b101: // OEx_U404 3'b100: // OEx_U404 default: // OEx_U404 endcase CS_MASK CS0 = !ECSx | (CSx[1] CS1 = !ECSx | (CSx[0] CS2 = !ECSx | (CSx[0] CS3 = !ECSx | (CSx[0] none masked = !ECSx | (CSx[0] & CSx[2] & CSx[3]); & CSx[2] & CSx[3]); & CSx[1] & CSx[3]); & CSx[1] & CSx[2]); & CSx[1] & CSx[2] & CSx[3]); OEx_U405 = OEx_U404; // check DIR_U400 DIR_U401 DIR_U404 DIR_U405 schematic for DIR level (different on LS boards) = 1; = 1; = !RDx; = !RDx; end endmodule © Fujitsu Microelectronics Europe GmbH FMEMCU-UG-910070-17 - 21 - EMA-MB91F467S-LS-176M07 Chapter 5: CPLD 5.2 NET NET NET NET NET NET NET NET NET NET NET NET NET NET NET NET NET NET NET NET NET NET NET NET NET NET NET NET NET NET NET NET 5.3 CPLD Constraints "ASx" LOC = "P13" ; "BAAx" LOC = "P14" ; "CSx" LOC = "P2" ; "CSx" LOC = "P1" ; "CSx" LOC = "P3" ; "CSx" LOC = "P5" ; "CSx" LOC = "P6" ; "CSx" LOC = "P7" ; "CSx" LOC = "P8" ; "CSx" LOC = "P12" ; "DIR_U400" LOC = "P39" | "DIR_U401" LOC = "P38" | "DIR_U404" LOC = "P36" | "DIR_U405" LOC = "P37" | "ECSx" LOC = "P32" ; "IORDx" LOC = "P18" ; "IOWRx" LOC = "P19" ; "OEx_U404" LOC = "P34" | "OEx_U405" LOC = "P33" | "RDx" LOC = "P44" ; "S401" LOC = "P31" ; "S401" LOC = "P30" ; "S401" LOC = "P29" ; "S401" LOC = "P28" ; "S401" LOC = "P27" ; "S401" LOC = "P23" ; "S401" LOC = "P22" ; "WEx" LOC = "P16" ; "WRx" LOC = "P40" ; "WRx" LOC = "P41" ; "WRx" LOC = "P43" ; "WRx" LOC = "P42" ; SLEW SLEW SLEW SLEW = = = = FAST FAST FAST FAST ; ; ; ; SLEW = FAST ; SLEW = FAST ; CPLD programming jumper (J491) The CPLD is re-configurable by programming via J491. Please refer to www.xilinx.com for details and tools for Xilinx CPLD configuration. HTU J491 pin Name 1 2 3 4 5 6 GND TDO TCK TMS TDI VREF FMEMCU-UG-910070-17 UTH © Fujitsu Microelectronics Europe GmbH - 22 - EMA-MB91F467S-LS-176M07 Chapter 6: Information in the WWW 6 Information in the WWW Information about FUJITSU MICROELECTRONICS Products can be found on the following Internet pages: Microcontrollers (8-, 16- and 32bit), Graphics Controllers Datasheets and Hardware Manuals, Support Tools (Hard- and Software) http://mcu.emea.fujitsu.com/mcu_portal.htm Linear Products: Power Management, A/D and D/A Converters http://www.fujitsu.com/emea/services/microelectronics Media Products: SAW filters, acoustic resonators and VCOs http://www.fujitsu.com/emea/services/microelectronics/saw For more information about FUJITUS MICROELECTRONICS http://www.fujitsu.com/emea/services/microelectronics © Fujitsu Microelectronics Europe GmbH FMEMCU-UG-910070-17 - 23 - EMA-MB91F467S-LS-176M07 Chapter 7: China-RoHS regulation 7 China-RoHS regulation Evaluation Board 评估板 Emulation Board 仿真板 根据SJ/T113642006《电子信息产品污染控制标识要求》特提供如下有关污染控制方面的信息。 The following product pollution control information is provided according to SJ/T11364-2006 Marking for Control of Pollution caused by Electronic Information Products. 1.电子信息产品污染控制标志说明 Explanation of Pollution Control Label 该标志表明本产品含有超过中国标准SJ/T113632006《电子信息产品中有毒有害物质的限量要求》中限量的有毒有害物质。标志中的数字为 本产品的环保使用期,表明本产品在正常使用的条件下,有毒有害物质不会发生外泄或突变, 用户使用本产品不会对环境造成严重污染或对其人身、财产造成严重损害的期限,单位为年。 为保证所申明的环保使用期限,应按产品手册中所规定的环境条件和方法进行正常使用,并严 格遵守产品维修手册中规定的定期维修和保养要求。 产品中的消耗件和某些零部件可能有其单独的环保使用期限标志,并且其环保使用期限有可能 比整个产品本身的环保使用期限短。应到期按产品维修程序更换那些消耗件和零部件,以保证 所申明的整个产品的环保使用期限。 本产品在使用寿命结束时不可作为普通生活垃圾处理,应被单独收集妥善处理。 请注意:环保使用期限50年的指定不是与产品的耐久力,使用期限或任何担保要求等同的。 This symbol to be added to all EIO sold to China, indicates the product contains hazardous materials in excess of the limits established by the Chinese standard SJ/T11363-2006 Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products. The number in the symbol is the Environment-friendly Use Period (EFUP), which indicates the period, starting from the manufacturing date, during which the toxic or hazardous substances or elements contained in electronic information products will not leak or mutate under normal operating conditions so that the use of such electronic information products will not result in any severe environmental pollution, any bodily injury or damage to any assets, the unit of the period is “Year”. FMEMCU-UG-910070-17 © Fujitsu Microelectronics Europe GmbH - 24 - EMA-MB91F467S-LS-176M07 Chapter 7: China-RoHS regulation In order to maintain the declared EFUP, the product shall be operated normally according to the instructions and environmental conditions as defined in the product manual, and periodic maintenance schedules specified in Product Maintenance Procedures shall be followed strictly. Consumables or certain parts may have their own label with an EFUP value less than the product. Periodic replacement of those consumables or parts to maintain the declared EFUP shall be done in accordance with the Product Maintenance Procedures. This product must not be disposed of as unsorted municipal waste, and must be collected separately and handled properly after decommissioning. Please note: The designation of 10 years EFUP is not to be equated with the durability, useduration or any warranty-claims of the product. 产品中有毒有害物质或元素的名称及含量 Table of hazardous substances name and concentration 有毒有害物质或元素 部件名称 EMA-MB91F467S-LS176M07 Hazardous substances name 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr(VI)) (PBB) (PBDE) x o o o o o O: 表示该有毒有害物质在该部件所有均质材料中的含量均在SJ/T11363-2006 标准规定的限量要求以下 X: 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出SJ/T11363-2006 标准规定的限量要求 • 此表所列数据为发布时所能获得的最佳信息 • 由于缺少经济上或技术上合理可行的替代物质或方案,此医疗设备运用以上一些有毒有害物质来实现设备的预期 临床功能,或给人员或环境提供更好的保护效果。 O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ/T11363-2006. X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ/T11363-2006. • Data listed in the table represents best information available at the time of publication © Fujitsu Microelectronics Europe GmbH FMEMCU-UG-910070-17 - 25 - EMA-MB91F467S-LS-176M07 Chapter 8: Recycling 8 Recycling Gültig für EU-Länder: Gemäß der Europäischen WEEE-Richtlinie und deren Umsetzung in landesspezifische Gesetze nehmen wir dieses Gerät wieder zurück. Zur Entsorgung schicken Sie das Gerät bitte an die folgende Adresse: Fujitsu Microelectronics Europe GmbH Warehouse Monzastraße 4a 63225 Langen Valid for European Union Countries: According to the European WEEE-Directive and its implementation into national laws we take this device back. For disposal please send the device to the following address: Fujitsu Microelectronics Europe GmbH Warehouse Monzastraße 4a 63225 Langen FMEMCU-UG-910070-17 © Fujitsu Microelectronics Europe GmbH - 26 -
EMA-MB91F467S-LS-176M07 价格&库存

很抱歉,暂时无法提供与“EMA-MB91F467S-LS-176M07”相匹配的价格&库存,您可以联系我们找货

免费人工找货