0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
461825

461825

  • 厂商:

    EXTECH

  • 封装:

  • 描述:

    461825 - Combination Photo-Tachometer Stroboscope - Extech Instruments Corporation.

  • 数据手册
  • 价格&库存
461825 数据手册
User’s Guide Combination Photo-Tachometer Stroboscope Model 461825 Introduction Congratulations on your purchase of Extech’s Combination PhotoTachometer/Stroboscope. This professional meter, with proper care, will provide years of safe reliable service. Meter Description 1 1. 2. 3. 4. 5. 6. 7. 8. Tachometer Light Source LCD Display Measure trigger button Memory Recall button FINE adjust knob COARSE adjust knob Range/Function select switch Stroboscope flash tube 2 3 4 5 6 7 Note: Battery compartment is on rear of meter 8 2 461825 Ver. 1.2 03/05 Operation STROBOSCOPE MEASUREMENT PROCEDURE Select the Stroboscope Function and Range using the Range/Function Select Switch. The switch has four positions, three of which are stroboscope-dedicated with white range numbers. The fourth position is Photo-Tachometer dedicated and is labeled as such. Speed Measurements. 1. Remove power to the moving object under test and affix a target mark on the area to be measured. 2. Apply power to the moving object and press the stroboscope's Measure Trigger Button. 3. Aim the Stroboscope light beam toward the marked area on the object under test. 4. Use the FINE and COARSE adjust knobs to synchronize or "stop" the motion of the object's mark. A single stationary image of the mark provides actual speed measurement data. NOTE: Care must be taken to ensure that the mark is providing a 1:1 measurement. This is done by checking that there is only one mark and not two, four, or more stationary marks on the object under test. Two or more stopped marks indicate "harmonic" measurements (2:1, 3:1, 4;1 etc.) which provide a doubling, tripling, or quadrupling of the actual speed. A useful method of avoiding harmonic measurements is to adjust the FINE/COARSE knobs until two images (marks) appear and then lower the flash rate (via COARSE/FINE knobs) until a single, stationary image appears. This is the actual speed. Inspecting a moving object. Measure the speed of a moving object as described above and move the FINE adjust knob alternately higher and lower to visually inspect all areas of the device. 3 461825 Ver. 1.2 03/05 PHOTO-TACHOMETER MEASUREMENT PROCEDURE 1. 2. 3. Select the Photo-Tachometer function by moving the Range/Function select switch to the PHOTO position. Affix a small piece (approx. 0.5") of supplied reflective tape to the object under test. Press the meter's Measurement Trigger button and align the PhotoTachometer light source with the reflective tape mark on the moving object. Wait until the Monitor Indicator appears in the upper left hand corner of the LCD indicating that synchronization has occurred. Release the Measure Trigger button only after the reading has stabilized (approx. 2 seconds). 4. 5. NOTE: To obtain better accuracy for low RPM measurements (less than 50 RPM) use more than one piece of reflective tape. Divide the meter reading by the number of reflective tape pieces for accurate measurement data. MEMORY RECORD AND RECALL The 461825 can record Maximum, Minimum, and Last Reading for the period of time during which the Measure Trigger button is held. These stored values can then be read directly on the meter's display. The memory will automatically erase after approximately 10 seconds of meter inactivity. Access the memory data immediately after the measurements. 1. 2. 3. Follow the instructions for normal operation. Release the Measurement Trigger button. Immediately press the Memory Recall button once to display the Last Reading taken during the measurement period. 'LA' will alternately display with the data reading to indicate 'Last Reading". Release and press the Memory Recall button again to display the Maximum reading taken during the measurement period. 'UP' will alternately appear with the data reading to indicate Max. reading. Release and press the Memory Recall button again to display the Minimum reading taken during the 30 second test period. 'dn' will alternately appear with the data reading to indicate Min. reading. 4. 5. 4 461825 Ver. 1.2 03/05 Specifications General Specifications Circuit Display Measurement units Memory Recall Operating Temperature Operating Humidity Power Supply Weight Dimensions Accessories Custom LSI microprocessor based design Reversible, 0.4" (10mm) 5-digit (99999 count) LCD display RPM (revolutions or rotations per minute) Records/Recalls Max/Min/Last readings with memory pushbutton 32 to 122oF (0 to 50oC) < 80% RH Four 1.5V 'AA" batteries (UM-3 or equivalent) 0.66 lb. (300g) 8.5x2.6x1.5" (215x65x38mm) Reflective tape and carrying case Electrical Specifications Measurement Range 5 to 99,999 RPM for the Tachometer 100 to 100,000 FPM/RPM for the Stroboscope 0.1 RPM ( 1000 RPM) ± (0.1% + 2 digits) 1 second (> 60 RPM) 2 to 6" (50 to 150mm) typical Note: Detection distances up to 12" (300mm) are possible depending upon ambient light 100 to 100,000 FPM (flashes per minute) Range A: 100 to 1,000 FPM Range B: 1000 to 10,000 FPM Range C: 10,000 to 100,000 FPM High efficiency LED lamp 60 to 1000 microseconds (approx. 16% of period) Orange Resolution Accuracy Sampling Time Photo Tachometer detection distance Stroboscopic Flash rate Stroboscopic Flash adjust range Stroboscopic Flash tube type Stroboscopic Flash duration Stroboscopic Flash Color 5 461825 Ver. 1.2 03/05 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Calibration and Repair Services Extech offers repair and calibration services for the products we sell. Extech also provides NIST certification for most products. Call the Customer Service Department for information on calibration services available for this product. Extech recommends that annual calibrations be performed to verify meter performance and accuracy. Support line (781) 890-7440 Technical support: Extension 200; E-mail: support@extech.com Repair & Returns: Extension 210; E-mail: repair@extech.com Product specifications subject to change without notice For the latest version of this User’s Guide, Software updates, and other up-to-the-minute product information, visit our website: www.extech.com Extech Instruments Corporation, 285 Bear Hill Rd., Waltham, MA 02451 Copyright © 2005 Extech Instruments Corporation All rights reserved including the right of reproduction in whole or in part in any form. 6 461825 Ver. 1.2 03/05
461825 价格&库存

很抱歉,暂时无法提供与“461825”相匹配的价格&库存,您可以联系我们找货

免费人工找货