0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
461880

461880

  • 厂商:

    EXTECH

  • 封装:

  • 描述:

    461880 - Vibration Meter and Laser Combination Tachometer - Extech Instruments Corporation.

  • 数据手册
  • 价格&库存
461880 数据手册
User's Guide Vibration Meter and Laser Combination Tachometer Model 461880 Introduction Congratulations on your purchase of the Extech 461880 Vibration Meter and Combination Laser Tachometer. The 461880 Vibration functions have a frequency sensitivity that meets ISO-2954, and measure Acceleration, Velocity and Displacement. A 1000 point datalogger allows recording of data for download to a pc with included software. The Tachometer functions provide contact RPM and Linear Surface Speed, as well as non-contact RPM measurements. The 461880 is shipped fully tested and calibrated and, with proper use and care, will provide years of reliable service. Features Vibration Function Features: 2 2 • Measures Acceleration from 0.5 to 199.9 m/s , 0.05 to 20.39 G or 2 to 656 ft/s • Measures Velocity from 0.5 to 200 mm/s , 0.05 to 19.99 cm/s or 0.02 to 7.87 in/s • Measures Displacement from 0.005 to 1.999 mm or 0.002 to 0.078 inches • RMS measurements for Acceleration and Velocity • Peak to Peak measurements for Displacement • Peak function for Acceleration and Velocity • Max Hold function for Acceleration (Peak), Velocity (Peak) and Displacement (Peak to Peak) • Frequency range from 10 Hz to 1 kHz meets ISO 2954 standards • Zero function • 1000 point datalogger with adjustable sample rate • Hold function freezes measured value on display • MAX/MIN function to record máximum and mínimum measured values • Auto Power-Off conserves battery power • Separate vibration sensor with magnetic mount included Tachometer Function Features: • Photo and Contact Tachometer functions • Laser light source with long measuring distance, up to 1.5 meters (4.9 feet) • Wide measurement range from 0.5 to 100,000 RPM • 0.1 RPM resolution ,1000 RPM, 1 RPM resolution >1000 RPM • Memory function with recall saved MAX, Min and Last Reading values • Microprocessor with crystal time base provides 0.05% accuracy General Features: • Large LCD display • Low Battery indicator • High Performance microprocessor based circuitry • Compact Heavy Duty housing • Hard Carrying case 2 461880 V1.0 5/09 Meter Description 1. 2. 3. 4. 5. 6. 7. 8. 9. Meter Top (see Meter Top Callout below) LCD display Tachometer Function pushbutton HOLD/ESCAPE pushbutton Power pushbutton ENTER/RECORD pushbutton FUNCTION/SEND pushbutton UNIT/LOGGER pushbutton Contact Tachometer Surface Speed wheel 10 11 12 13 10. Contact Tachometer RPM adapter 11. Velocity Sensor and Magnetic Mount 12. Contact Tachometer Protective Cover 13. Access Screw for Protective Cover Meter Top 1. 2. 3. 4. 5. BNC Connector Photo Tachometer Laser Light source Photo Tachometer Laser Detector IR Temperature probe input (feature not supported) RS232 Output Terminal 1 2 3 4 5 Meter LCD Display 3 461880 V1.0 5/09 Vibration Meter Operation Connecting Probe 1. Note that this meter accepts only the supplied vibration probe. 2. Plug the BNC connector end of the probe cable onto the BNC connector at the top of the meter. 3. The probe can then be connected to the tested machinery in three ways: a. Attach the magnetic end of the probe to a ferrous material on the equipment under test. b. Manually hold the probe in place against the equipment under test. c. Unscrew the magnet from the probe end and use the threaded mount to connect to a screw, bolt, or stud on the equipment under test. 4 461880 V1.0 5/09 Powering the meter 1. 2. Press the POWER key once to power the meter On. The meter will perform a short self-test. Press and hold the POWER key to power the unit Off. The unit will beep and display OFF. Selecting Units 1. 2. 3. The unit powers on in Acceleration mode (ACC ft/s ). Use the UNIT/LOGGER key to scroll through the other available functions/units: Velocity (VEL in/sec), Displacement (DISP inch). The 461880 defaults to Imperial units (feet, inches, etc.). To change the readout to metric units, press and hold the UNIT/LOGGER key for 2 seconds. The readout will change to Metric units (meters, centimeters, etc.). To change back to Imperial units, press and hold the UNIT/LOGGER key again for 2 seconds, or, power the unit OFF and back ON. 2 RMS, PEAK, PEAK MAX HOLD, MAX HOLD Press the FUNCTION/SEND key to select RMS, PEAK, or PEAK MAX HOLD (ACC and VEL); or PEAK or PEAK MAX-HOLD (DISP). 1. 2. 3. 4. 5. RMS - Typical selection for vibration measurements. (PEAK to PEAK for Displacement) PEAK – For measurement of the peak value. Not available in the Displacement mode. PEAK MAX HOLD – Holds and displays the maximum value. The display will update only when a new maximum is measured. Not available in the Displacement mode. MAX HOLD – Holds and displays the maximum Peak to Peak value. Available in Displacement mode only. To clear the MAX HOLD or PEAK MAX HOLD values, press the HOLD/ESCAPE key for more than 2 seconds. This will zero the display and restart the MAX HOLD or PEAK MAX HOLD function. DATA HOLD To freeze the LCD display, momentarily press the HOLD/ESC key. The HOLD icon will appear on the upper right-hand corner of the LCD. Momentarily press the HOLD/ESC key again to return to normal operation (the HOLD' hold icon will disappear). MAX/MIN Record Function 1. Press the REC key to enter the MAX/MIN record mode. The REC icon will appear on the display. Subsequent presses of the Record key will select the Max or MIN record mode. Press and hold the RECORD key for more than 2 seconds. To delete the MAX/MIN recorded values, press the HOLD button while the MAX/MIN value to be erased is on the display. The value will be erased and the MAX or MIN icon will disappear. The unit will remain in Record mode until the REC key is held for more than 2 seconds. 2. 5 461880 V1.0 5/09 ZERO Adjustment Procedure The meter may not indicate zero with no signal applied to the meter (no vibration). Although this is usually not a problem, this procedure will bring the meter within a few digits of zero and improve measurement precision. 1. Connect the vibration sensor to the meter. 2. 3. 4. Turn the meter on and set the function to ACC and RMS. Make sure the vibration sensor is perfectly still (no vibration). Press and hold the HOLD/ESC key for > 2 seconds to allow the display to reach the zero value. Advanced Vibration Functions The Advanced Functions Menu allows adjustment for the Auto-Power Off feature and Datalogging Sample Rate, as well as access to Memory status, and to Clear memory 1. Press and hold the HOLD/ESC key while powering the unit ON. Repeated presses of the HOLD/ESC key will scroll through the available functions: OFF – Auto-Power Off SEC – Datalogger Sample Rate Cnt – Number of data points available in memory CLr – Clear Datalogger Memory ESC – Exits the Advanced Functions Menu 2. Press the HOLD key to select the OFF function. Use the FUNCTION/SEND key or UNIT/LOGGER key to toggle the setting between “0” and “1”. “0” disables the AutoPower Off function. “1” enables the function. Press the ENTER key to save the setting. Press the HOLD/ESC key to select the SEC function. Use the FUNCTION/SEND key or UNIT/LOGGER key to scroll through the available sample rates: 1, 2, 10, 30, 60, 600, 1800, or 3600 seconds. Press the ENTER key to save the setting. Press the HOLD/ESC key to select the Cnt function. The display will flash the available Memory points available in the datalogger. Press the HOLD/ESC key to select the CLr function. Use the FUNCTION/SEND key or UNIT/LOGGER key to toggle the setting between “0” and “1”. Select “1” to clear the datalogger memory. Select “0” to retain the data in memory. Press the ENTER key to execute. Press the HOLD/ESC key to select the ESC function. Press the HOLD/ESC key again to exit the Advanced Functions menu. The meter will power OFF. 3. 4. 5. 6. 6 461880 V1.0 5/09 Tachometer Operation Safety WARNING: Do not directly view or direct the laser pointer at an eye. Low power visible lasers do not normally present a hazard, but may present some potential for hazard if viewed directly for extended periods of time. Reversible LCD Display The meter display indicates Photo Tachometer measurements in one direction and Contact measurements in the opposite direction. This permits the user to easily read the measurement digits in both measurement modes with the meter held in either direction. Selecting Function and Units Press and hold the Tachometer Function pushbutton on the right side of the 461880. Repeated presses of the FUNCTION/SEND key will scroll through the available modes: RPM – Contact RPM measurement. M/min – Surface speed - Meters per Minute measurement. Ft/min – Surface Speed - Feet per Minute measurement. RPM – Non-contact RPM measurement. NON-CONTACT PHOTO TACHOMETER MEASUREMENTS 1. 2. Apply an appropriately sized square piece of reflective tape to the surface of the object under test. Point the laser pointer end of the meter toward the device under test. Press and hold the Tachometer Function Pushbutton (located on the right side of the meter). Press the FUNCTION/SEND key to select the non contact RPM mode. Align the laser pointer beam with the reflective tape. Verify that the ((●)) Monitor Indicator appears on the LCD when the object under test passes through the light beam. If the measurement is under 50 RPM, apply additional squares of reflective tape. Divide the reading shown on the display by the number of pieces of reflective tape squares used to calculate the actual reading. When the reading on the display stabilizes, note the reading. 3. 4. 5. NOTE: Bright ambient light may interfere with the reflected light beam. Shading the target area may be necessary in some cases. CAUTION: Rotating objects can be dangerous. Use extreme care. 7 461880 V1.0 5/09 CONTACT TACHOMETER RPM MEASUREMENTS 1. 2. 3. 4. 5. Remove the Tachometer Protective Cover by loosening the screw and gently pulling the cap away from the unit. Install one of the RPM contact tips (stored inside the Tachometer Protective Cover) on the contact shaft. Press and hold the Tachometer Function Pushbutton (located on the right side of the meter). Press the FUNCTION/SEND key to select the contact RPM mode. Lightly press the contact tip against the center of a rotating shaft. When the reading on the display stabilizes, note the reading. CONTACT LINEAR SURFACE SPEED (ft/min or m/min) MEASUREMENTS 1. Remove the Tachometer Protective Cover by loosening the screw and gently pulling the cap away from the unit. 2. Press and hold the Tachometer Function Pushbutton (located on the right side of the meter). Press the FUNCTION/SEND key to select one of the linear speed modes (M/min or ft/min). Lightly press the linear speed wheel on the moving surface to be measured. When the reading on the display stabilizes, note the reading. 3. 4. RECALLING CONTACT TACHOMETER READINGS To recall Contact Tachometer readings, press and hold the ENTER/REC key. Values are displayed in 3 modes: LA – Last reading displayed. UP – Maximum value recorded dn – Minimum value recorded Repeatedly pressing and holding the ENTER/REC key will scroll through the 3 modes. The value will flash, alternating between the mode indicator and value. 8 461880 V1.0 5/09 Datalogging The internal datalogger memory can hold up to 1000 readings. Readings can be logged manually, with a button press, or automatically, at a programmed sample rate. Sample Rate The sample rate can be set to 0 (manual), 1, 2, 5, 10, 30, 60, 600, 1800 or 3600 seconds. See the Advanced Vibration Functions section for instructions on setting the sample rate. Auto Data Logging 1. 2. 3. 4. 5. 6. 1. 2. 3. 4. 5. 6. Set the desired sample rate as described (do not select ‘0’). Turn the meter off and back on. Press the REC button to enter the datalogging function. The REC symbol will appear in the display (upper left-hand corner). Press the LOGGER button to start logging data. ((●)) indicator will flash in time with the selected sample rate. Press and Hold the LOGGER button for > 2 seconds to pause/resume datalogging. Press and Hold the REC button > 2 seconds to exit the datalogging mode. Set the sample rate to ‘0’ as described earlier. Turn the meter off and back on. Press the REC to enter the datalogging function. The REC symbol will appear in the display flashing. Press the LOGGER button. Press LOGGER again to log one data point. The ((●)) indicator will flash and an audible tone will sound. Repeat this step to store the desired number of readings. Press and Hold the REC button > 2 seconds to exit the datalogging mode. Manual Data Logging 9 461880 V1.0 5/09 PC Interface The meter is equipped with an RS-232 serial data port (located at the top of the meter next to the probe input jack). This interface was designed to operate with the optional Extech 407001A software package, which includes two programs and the required meter to pc interface cable. 1. 407001A - Extech Data Acquisition Software: This software allows the user to connect the meter to a PC and view readings in real-time as they are taken (this software does not download the contents of the meter’s memory to the PC) DL2005 - Datalogger Download Software: This software allows the user to download the contents of the meter’s memory to the PC 2. Download Stored Data to PC (requires DL2005 software) The SEND button is used to send the contents of the meter’s internal datalogger memory to the PC via the optional DL2005 software. 1. 2. 3. 4. 5. 6. Connect the RS-232 cable to the PC Install and run the DL2005 data logging software. Press and hold the SEND button for > 2 seconds. “r-232” will flash repeatedly in the display. In the DL2005 software, press START. Press the SEND button again and the data will be sent to the meter’s RS-232 port and onto the connected PC. Press the ESC button to return to normal operation. Specifications Display Sampling Time Datalogger memory Datalogger Sample Time Over range indication Open input indication Low battery indication Power supply Power Consumption Auto-Power Off Operating Temperature Operating Humidity Storage Temperature Storage Humidity Dimensions Weight Dual Display Multi-function LCD Approximately 1 second 1000 point memory 0 (manual), 1, 2, 10, 30, 60, 600, 1800 and 3600 sec. "OL" appears on the LCD "0" appears on the LCD Battery symbol appears on the LCD 4 x 1.5V AA Batteries Vibration: approximately 10.5 mA Tachometer: approximately 21 mA On/Off selectable o o 32 to 122 F (0 to 50 C) less than 80% RH o o 14 to 140 F (-10 to 60 C) 10 to 80% RH Meter: 7.4 x3.0x1.8" (188x75.5x46.8mm) Probe: 18 mm diameter, 40 mm height Meter: 0.87 lbs (397g) Probe: 0.24 lbs (110g) 10 461880 V1.0 5/09 Vibration Functions Unit Acceleration(RMS or Peak) m/s G ft/s 2 2 Range 0.5 to 199.9m/s 0.05 to 20.39G 2 to 656ft/s 2 2 2 Accuracy (% of reading) ±(5% + 2 digits) Velocity (RMS or Peak) Calibration point: 50 m/s @ 160Hz mm/s 0.5 to 199.9mm/s cm/s 0.05 to 19.99cm/s in/s 0.02 to 7.87in/s Calibration point: 50mm/s @ 160Hz mm 0.005 to 1.999mm inch 0.002 to 0.078in Calibration point: 0.14mm @ 160Hz ±(5% + 2 digits) Displacement (peak to peak) ±(5% + 2 digits) Note: Accuracy stated from 80 to 160Hz @ 23 ± 5°C Frequency Range 10 Hz to 1 kHz – meets ISO 2954 Tachometer Functions Range Photo Tachometer Contact Tachometer Surface Speed Surface Speed Photo Tachometer Detecting Distance 10 to 99,999 rpm Resolution 0.1 rpm (1000 rpm) 0.1 rpm (1000 rpm) 0.1 ft/min (1000ft/min) 0.01 m/min (100 m/min) Accuracy (%rdg) ± (0.05% + 1d) 0.5 to 19,999 rpm 0.2 to 6560 ft/min 0.05 to 1999.9 m/min ± (1% + 1d) 2 to 59” (50 to 1,500mm) typical* * specified using a 10mm square of reflecting tape at 1,800rpm. The max and min detecting distance will change with environmental conditions, reflecting tape, or speeds above 1800rpm. 11 461880 V1.0 5/09 Warranty EXTECH INSTRUMENTS CORPORATION (A FLIR COMPANY) warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Calibration and Repair Services Extech offers repair and calibration services for the products we sell. Extech also provides NIST certification for most products. Call the Customer Care Department for information on calibration services available for this product. Extech recommends that annual calibrations be performed to verify meter performance and accuracy. Support line (781) 890-7440 Technical Support: Extension 200; E-mail: support@extech.com Repair & Returns: Extension 210; E-mail: repair@extech.com Product specifications subject to change without notice For the latest version of this User Guide, Software updates, and other up-to-the-minute product information, visit our website: www.extech.com Extech Instruments Corporation, 285 Bear Hill Road, Waltham, MA 02451 Copyright © 2009 Extech Instruments Corporation (a FLIR company) All rights reserved including the right of reproduction in whole or in part in any form. 12 461880 V1.0 5/09
461880 价格&库存

很抱歉,暂时无法提供与“461880”相匹配的价格&库存,您可以联系我们找货

免费人工找货