0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BR146

BR146

  • 厂商:

    EXTECH

  • 封装:

  • 描述:

    BR146 - Flexible Borescope - Extech Instruments Corporation.

  • 数据手册
  • 价格&库存
BR146 数据手册
User's Guide Flexible Borescope Model BR146 Introduction Congratulations on your purchase of the Extech BR146. This product is used for inspection of areas generally inaccessible to the naked eye, such as internal inspection of engines, gear train components, interior structures of walls, and industrial applications. Illumination is provided by two solid state LEDs which are controlled by a three position switch, giving low, off, and high output. Lighting is powered by 4 “AA” batteries located in the handle. The adjustable eyepiece focus allows the user to fine tune for object distance. The scope comes in a protective case for storage. An accessory mirror allows the user to see 90 degrees to the axis of the shaft. The Magnet accessory will pick up approx 1/4 lb. This device is shipped fully tested and, with proper use, will provide years of reliable service Safety STOP IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO COULD CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE USE. • • • • • DO NOT use flexible inspection scope if damaged Do not point the tip toward the Sun or other intense source of light while viewing. Permanent eye damage may occur. Maintain your scope in new condition as detailed in MAINTENANCE for long service Be aware of your surrounding environment while using your inspection scope Account for all tools and parts being used or serviced and do not leave loose parts near moving parts of an engine Specifications Viewing distance: Viewing Angle Side View Adaptor: Tip Diameter Working Length: Maximum bend radius Optical system: Illumination Max probe temperature Shaft material Housing material Compatibility Power Weight: Carrying Case Dimensions: 0.4”(10mm) to infinity 48° 90° 0.39” (10mm) 46” (1168mm) 3” (7.62cm) fiber optic (7400 fibers) LED (2) (High/Low intensity selection) 158°F / 70°C HDPF Nylon Water, diesel, gasoline, brake fluid, antifreeze, motor oil, gear oil and other liquids 4 AA batteries 1.15lb (0.52kg) 17 x 13 x 4.5” (432mm x 330mm x 114mm) 2 BR146 V2.0 9/08 Description 1. Eyepiece and Focus 2. LED ON and intensity switch 3. Handle 4. Battery compartment 5. Shaft 6. Tip and Light source 1 2 3 4 5 6 Operation WARNING! Be careful when inserting or removing the scope shaft from the equipment under inspection. WARNING! Use extra care when using mirror or magnet accessories. Accessories may detach if snagged. DO NOT bend any part of the shaft tighter than a 3 inch radius ( 6 inch diameter). DO NOT expose the scope housing to water or other fluids. DO NOT insert the scope shaft and tip into locations whose temperature is greater than 158º/F70ºC. 1. Note the location and distance of the object to be inspected and determine the best route to it. Bend the shaft to follow the route. 2. View the object through the eyepiece. Adjust the focus as necessary by turning the eyepiece. 3. Press the switch below the eyepiece to turn on the LED light. A left press is high intensity, right press is low intensity (extends battery life). 4. Attach the side view mirror or retrieval magnet to the tip as shown. Make sure the spring clip is fully secure in the recessed groove provided. NOTE: The base of the mirror or magnet should be aligned over the flat side of the tip. Maintenance BATTERY REPLACEMENT WARNING ! Make sure switch is in the off position prior to maintenance and/or battery replacement. 1. Remove the battery housing door with a Phillips screwdriver. 2. Un-clip the connector - if required - and replace batteries in the pack. Dispose of batteries properly. 3. Re-attach connector and re-insert battery pack into bottom of handle. 4. Re-assemble battery door. Do not over tighten screw. CLEANING AND STORAGE After each use, wipe down the tip and shaft with a clean, dry cloth to remove fluids and residue. If needed, clean the shaft with a cloth dampened with a mild soap detergent Gently clean the lens and eyepiece with a cotton swab dampened with a lens cleaner such as isopropyl alcohol. NOTE: Your inspection scope MUST be completely dry before returning it to the storage case. 3 BR146 V2.0 9/08 Warranty EXTECH INSTRUMENTS CORPORATION (A FLIR COMPANY) warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Calibration and Repair Services Extech offers repair and calibration services for the products we sell. Extech also provides NIST certification for most products. Call the Customer Care Department for information on calibration services available for this product. Extech recommends that annual calibrations be performed to verify meter performance and accuracy. Support line (781) 890-7440 Technical Support: Extension 200; E-mail: support@extech.com Repair & Returns: Extension 210; E-mail: repair@extech.com Product specifications subject to change without notice For the latest version of this User Guide, Software updates, and other up-to-the-minute product information, visit our website: www.extech.com Extech Instruments Corporation, 285 Bear Hill Road, Waltham, MA 02451 Copyright © 2008 Extech Instruments Corporation (a FLIR company) All rights reserved including the right of reproduction in whole or in part in any form. 4 BR146 V2.0 9/08
BR146 价格&库存

很抱歉,暂时无法提供与“BR146”相匹配的价格&库存,您可以联系我们找货

免费人工找货