0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MN26

MN26

  • 厂商:

    EXTECH

  • 封装:

  • 描述:

    MN26 - Mini Autoranging MultiMeter - Extech Instruments Corporation.

  • 数据手册
  • 价格&库存
MN26 数据手册
User’s Manual MiniTecTM Series Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter Introduction Congratulations on your purchase of Extech’s MN26 Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency, Duty Cycle, Temperature, Diode Test and Continuity. Proper use and care of this meter will provide many years of reliable service. Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present Double insulation Safety Precautions 1. Improper use of this meter can cause damage, shock, injury or death. Read and understand this user manual before operating the meter. 2. Make sure any covers or battery doors are properly closed and secured. 3. Always remove the test leads before replacing the battery or fuses. 4. Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Repair any damage before use. 5. Do not exceed the maximum rated input limits. 6. Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC. These voltages are considered a shock hazard. 7. Always discharge capacitors and remove power from the device under test before performing Capacitance, Diode, Resistance or Continuity tests. 8. Remove the battery from the meter if the meter is to be stored for long periods. 9. To avoid electric shock, do not measure AC current on any circuit whose voltage exceeds 250V AC. 10. Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the electrical contacts. Other means should be used to ensure that the terminals are not "live". Specifications Function DC Voltage (V DC) Range 400mV 4V 40V 400V 600V 400mV 4V 40V 400V 600V 400µA 4000µA 40mA 400mA 10A Resolution 0.1mV 0.001V 0.01V 0.1V 1V 0.1mV 0.001V 0.01V 0.1V 1V 0.1µA 1µA 0.01mA 0.1mA 0.01A 2 Accuracy ±(0.5% reading + 2 digits) ±(1.0% reading + 2 digits) ±(1.5% reading + 2 digits) ±(2.0% reading + 30 digits) ±(1.5% reading + 3 digits) ±(2.0% reading + 4 digits) ±(1.5% reading + 3 digits) AC Voltage (V AC) (40 - 400Hz) (40 - 200Hz for 400mV, 4V ranges) DC Current (A DC) ±(2.5% reading + 5 digits) MN26T V4.0 05/05 Function AC Current (A AC) (40 - 400Hz) (40 - 200Hz for 400µA, 4mA ranges) Resistance Range 400µA 4000µA 40mA 400mA 10A Resolution 0.1µA 1µA 0.01mA 0.1mA 0.01A Accuracy ±(1.8% reading + 5 digits) ±(3.0% reading + 7 digits) Capacitance Frequency Duty Cycle Temp °F Temp °C 400Ω 0.1Ω ±(1.2% reading + 4 digits) ±(1.2% reading + 2 digits) 4k Ω 0.001kΩ 40kΩ 0.01kΩ 400kΩ 0.1kΩ 4M Ω 0.001MΩ 40MΩ 0.01MΩ ±(2.0% reading + 3 digits) 4nF 0.001nF ±(5.0% reading + 10digits) 40nF 0.01nF ±(5.0% reading + 7 digits) 400nF 0.1nF ±(3.5% reading + 5 digits) 4µF 0.001µF 40 µ F 0.01µF 200µF 0.1µF ±(5.0% reading + 5 digits) 9.999Hz 0.001Hz ±(1.5% reading + 5 digits) 99.99Hz 0.01Hz 999.9Hz 0.1Hz ±(1.2% reading + 2 digits) 9.999kHz 0.001kHz 99.99kHz 0.01kHz 999.9kHz 0.1kHz 9.999MHz 0.001MHz ±(1.5% reading + 4 digits) Sensitivity: 0.8V rms min. @ 20% to 80% duty cycle and 100kHz. 0.1 to 99.9% 0.1% ±(1.2% reading + 2 digits) Pulse width: 100µs - 100ms -4 to 1400°F* 1°F ±(3.0% reading + 3 digits) (probe effect additional) -20 to 760°C* 1°C o o o o NOTE: Accuracy is stated at 65 F to 83 F (18 C to 28 C) and less than 70% RH. NOTE: Temperature range of the temperature probe may be less than the range of the meter. Input Limits Function Maximum Input V DC, VAC 600V DC/AC Ohms, Capacitance, Diode, Frequency, 250V DC/AC Continuity mA DC/AC 400mA DC/AC 10A DC/AC 10A DC/AC (30sec. max) 3 MN26T V4.0 05/05 Diode Test Continuity Check Input Impedance Display Overrange indication Polarity Measurement Rate Auto Power Off Low Battery Indication Batteries Fuses Operating Temperature Storage Temperature Relative Humidity Operating Altitude Weight Size Safety Test current of 0.3mA maximum, open circuit voltage 1.5V DC typical Audible signal will sound if the resistance is less than approximately 30Ω, test current

很抱歉,暂时无法提供与“MN26”相匹配的价格&库存,您可以联系我们找货

免费人工找货
DMN26D0UT-7
  •  国内价格
  • 1+0.7908
  • 100+0.73808
  • 300+0.68536
  • 500+0.63264
  • 2000+0.60628
  • 5000+0.59047

库存:0

TPDMN26D0UFB4
  •  国内价格
  • 5+0.1155
  • 20+0.105
  • 100+0.0945
  • 500+0.084
  • 1000+0.0791
  • 2000+0.0756

库存:8384

TPDMN26D0UFB4
  •  国内价格
  • 5+0.13012
  • 20+0.11843
  • 100+0.10674
  • 500+0.09506
  • 1000+0.0896
  • 2000+0.08571

库存:9980

DMN26D0UFB4-7
  •  国内价格
  • 10+0.24023
  • 50+0.22218
  • 200+0.20713
  • 600+0.19209
  • 1500+0.18006
  • 3000+0.17254

库存:3431