0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MO250

MO250

  • 厂商:

    EXTECH

  • 封装:

  • 描述:

    MO250 - Moisture Meter - Extech Instruments Corporation.

  • 数据手册
  • 价格&库存
MO250 数据手册
User Guide Moisture Meter Model MO250 Introduction Congratulations on your purchase of the Extech MO250 Moisture Meter. The MO250 detects moisture in wood and other building materials such as brick, wall board, sheet rock, cardboard, paper, plaster, concrete, and mortar. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Features • • • • • • • • • Designed to check the moisture level of wood, concrete, and other non-wood material Measures from 6% to 40% moisture in wood Measures 13% to 100% relative moisture for concrete and other non-wood material Measurements are shown on Red LED bargraph indicator and LCD digital display Optional external moisture sensor probe (MO252) for remote moisture measurements Microprocessor provides high accuracy and advanced features such as MAX / MIN Data Hold feature freezes displayed reading Heavy duty construction and compact housing enhance portability and durability Low battery indicator alerts user when battery needs replacing Description Meter Description 1. 2. 3. 4. 5. 6. 7. 8. 9. External probe input Measurement electrode pins LCD display POWER key HOLD key REC MAX/MIN key MATERIAL key LED bargraph External probe plug 10. External probe (Optional) Notes: • • • External probe is optional (use part number MO252 to order probe) Battery compartment, tilt stand, and tripod mount are located on the rear of the instrument Electrode pin protective cover not shown 2 MO250 V2.1 6/06 Operation Electrode Pins CAUTION: The electrode measurement pins are extremely sharp. Use care when handling this instrument. Cover the pins with the protective cap when the instrument is not in use. The electrode pins are replaceable / removeable and must be inserted before the meter can be used. To insert or replace the pins refer to the illustration and instructions below: a) Remove the protective cap at the top of the meter b) c) d) To remove the pins, loosen the locknut at the base of the electrode pins Install the new pins and tighten the locknuts Replace the protective cap 1. 2. 3. 4. Basic Operation 1. 2. 3. Remove the protective cap to expose the electrode pins. Press the POWER key to turn the meter ON / OFF. Press the MATERIAL key to select the material under test. A ‘1’ will appear in the right bottom display for concrete and other non-wood material. A ‘2’ will appear for wood. See details below: Material 1: 13 to 100% relative moisture for concrete and other non-wood materials; display shows a ‘1’ on the bottom right. Electrode pins Locking nuts Threaded posts Electrode jacks at top of meter 1 2 3 4 25.0 36.9 3 % 1 % Material 2: 6% to 40% moisture range for wood; the display shows a ‘2’ on the bottom right. 2 MO250 V2.1 6/06 4. 5. 6. 7. Carefully push the electrode pins a minimum of 0.07” (2mm) into the material under test. Note that the pins should be inserted into wood perpendicular to the wood’s fiber structure. For high moisture readings, it may 0.07” (2mm) take several minutes for the meter reading to stabilize. Take several readings in several locations on the material for the best representation of the amount of moisture present. Read the measurement values on the LCD digital display or the LED bar graph (see bargraph diagram) Replace the protective cap when finished. 1. 2. 3. 4. 5. 6. 7. Material 1 (non-wood) moisture scale 13-100% Material 2 (wood) moisture scale 6-40% LED bargraph reading Color code for material 2 (High Moisture) Color code for material 2 (Medium Moisture) Color code for material 2 (Low Moisture) Color code for material 1 (High Moisture when LEDs reach darker color) Data Hold feature The Data Hold function freezes the reading in the display. Press the HOLD key momentarily to activate the Data Hold function. The reading will freezee and the ‘HOLD’ display icon will appear. Press the HOLD key again to exit the Data Hold function (the HOLD display icon will switch off). Max/Min Memory feature The meter’s Max/Min feature allows the user to take multiple readings while storing the highest (Max) and lowest (Min) readings. 1. 2. Press the REC MAX/MIN key to activate the MAX/MIN recording mode. The display icon ‘REC’ will appear. Now begin taking measurements. To view the MAX reading, press the REC MAX/MIN key again. The display icon ‘MAX’ and the maximum recorded value will appear on the display. The meter will now display and hold the maximum reading. To return back to the MAX/MIN recording mode, press the ‘HOLD’ key. It will update only when a new ‘Max’ occurs. To view the stored Min reading, press the REC MAX/MIN key again. The display icon ‘REC MIN’ and the minimum value will appear on the display. The meter will display and hold the minimum reading. To return back to the MAX/MIN recording mode, press the HOLD key. It will update only when a new ‘Min’ occurs. To exit MAX/MIN mode press and hold the REC MAX/MIN key for 2 seconds then release. The display icon ‘REC’ will switch off. 3. 4. 4 MO250 V2.1 6/06 External Probe (optional) An optional external probe is available (part number MO252) that allows the user to reach into areas that would be difficult to access with the meter’s built-in electrode pins. 1. 2. 3. The input socket for the external probe is located at the top of the meter. The plug and jack are keyed so that the plug can only fit in the jack one way. Turn the plug carefully until it lines up with the jack and then firmly push the plug in place. Do not apply undue force or try to twist the plug side-to-side. 4. The meter will continue to operate as described in this manual. Battery Replacement If the instrument does not switch ON or displays the low battery symbol battery as follows: 1. 2. 3. • • • , replace the Open the rear battery cover by removing the screw using a Phillips head screwdriver Replace the 9V battery Put the battery cover back in place. Secure with the Phillips screw. Maintenance Always keep the instrument dry To clean, wipe the meter with a damp cloth. Use a mild detergent if necessary but never use abrasives or solvents. Prevent dirt from accumulating at the electrode pins Specifications Display Resolution Accuracy Sampling rate Memory Measurement principle Range Electrode pin length Electrode pin type Power supply Power consumption Low Battery Indication Meter housing Operating Temperature Operating Humidity Dimensions Weight LCD digital display and red LED bargraph scale 0.1% ± (5% rdg + 5 digits) One reading every 0.8 seconds (approx.) Maximum and Minimum readings can be saved and viewed Electrical resistance Wood: 6 to 40%, Building materials: 13 to 100% 0.44” (11mm) Integrated, replaceable 9V alkaline battery 16mA DC (approx.) Battery symbol displayed on LCD Impact-proof plastic 32 to 122 F (0 to 50 C) 80% Relative Humidity maximum 8.4 x 2.7 x 1.2” (216.5 x 68.5 x 29.7mm) 8.8 oz. (251g) 5 MO250 V2.1 6/06 o o Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Calibration and Repair Services Extech offers repair and calibration services for the products we sell. Extech also provides NIST certification for most products. Call the Customer Service Department for information on calibration services available for this product. Extech recommends that annual calibrations be performed to verify meter performance and accuracy. Support line (781) 890-7440 Technical support: Extension 200; E-mail: support@extech.com Repair & Returns: Extension 210; E-mail: repair@extech.com Product specifications subject to change without notice For the latest version of this User’s Guide, Software updates, and other up-to-theminute product information, visit our website: www.extech.com Extech Instruments Corporation, 285 Bear Hill Rd., Waltham, MA 02451 Copyright © 2006 Extech Instruments Corporation All rights reserved including the right of reproduction in whole or in part in any form. 6 MO250 V2.1 6/06
MO250 价格&库存

很抱歉,暂时无法提供与“MO250”相匹配的价格&库存,您可以联系我们找货

免费人工找货