SHEATH TYPE THERMOCOUPLE
DATA SHEET
This thermocouple is firmly sealed with high-purity oxidized magnesium (insulating material) in a fine metallic protective tube without air gaps, together with the thermocouple element. Unlike ordinary type thermocouples, it provides excellent sensitivity and vibration resistance, and is designed to permit easy bending work.
FTJ, K, E
FEATURES
1. Thermocouple tube is very small in size, providing excellent sensitivity. 2. Adoption of integrated structure has improved the vibration resisting characteristic. 3. Easy bending work allows fabricating a long-sized thermocouple for easy measurement even in a place where ordinary type thermocouples cannot be used. 4. Thermocouple strand is not exposed to air, ensuring a long life with minimum deterioration or breaks of wire, unlike ordinary type thermocouples. 5. A variety of protective tube materials are available for selection according to applications. 6. Various types of terminals such as extension cable type, connector type, exposed type, terminal box type, etc., are also available for selection according to applications.
Class :
Class 1 2 3 Note: Class 3 is applied only for low temperature of less than 40˚C. Class 3 is permitted only for FTK, FTE. Remarks
Temperature tolerance :
Symbol Class Measured temperature (˚C) -40˚C or more, less than +375˚C 375˚C or more, less than 1000˚C -40˚C or more, less than +333˚C 333˚C or more, less than 1200˚C -167˚C or more, less than +40˚C -200˚C or more, less than -167˚C -40˚C or more, less than +375˚C 375˚C or more, less than 800˚C -40˚C or more, less than +333˚C 333˚C or more, less than 900˚C -167˚C or more, less than +40˚C -200˚C or more, less than -167˚C -40˚C or more, less than +375˚C 375˚C or more, less than 750˚C -40˚C or more, less than +333˚C 333˚C or more, less than 750˚C Tolerance ±1.5˚C ±0.004•|t| ±2.5˚C ±0.0075•|t| ±2.5˚C ±0.015•|t| ±1.5˚C ±0.004•|t| ±2.5˚C ±0.0075•|t| ±2.5˚C ±0.015•|t| ±1.5˚C ±0.004•|t| ±2.5˚C ±0.0075•|t|
SPECIFICATIONS
• Applied standard: JIS C 1605-1995 • Thermocouple element: Component material
Component material Kind + foot Iron Alloy made of nickel and chrome Alloy made of nickel and chrome - foot Alloy made of copper and nickel Alloy made of nickel Alloy made of copper and nickel
1 E 2 3 1 J 2 1 K 2 3
J
K
E
(Note) "+foot " is connected to theterminal (+) of instrument for measuring thermal electromotive force, and ''- foot '' is connected to opposite side.
Note: Tolerance means the maximum allowable limit of the value calculated by subtracting the temperature of the temperature measuring junction from the temperature obtained by converting the thermal electromotive force by the reference thermal electromotive force. |t| is the value indicated by temperature (˚C) that is not related to + or - symbol of the measured temperature.
EDS2-9b
Date Jun. 6, 2006
FTJ, K, E
• Sheath material : SUS347, SUS310S, SUS316 or Inconel • Sheath outside diameter : φ1.6, φ3.2, φ4.8 or φ6.4mm • Mounting method : Insertion type or screw-in type (with mounting bracket) Mounting screw size: R1 /8 (PT1 /8)or R1 /4 (PT1 /4) • Insertion length : 100~9000mm (specified in 10mm base) • Terminal structure : Extension cable type, connector type, exposed type, terminal box type, and extension cable (with connector) type • Temperature limit : (Unit:˚C)
Sheath outside diameter (mm) Sheath Kind material(*) K E J 1.6 A 650 650 450 – – B A 750 750 650 – – 3.2 B A 4.8 B A 6.4 B
• Element structure : Single-core: insulation type, Twin-core: insulation type Single-core; grounding type, Twin-core: grounding type (Note) Twin-core type : φ3.2mm or more • Minimum bending radius : 5 times larger than sheath outside diameter •Response characteristic : See table below.
800 900 800 1000 800 750 – – 800 750 – –
(Note*) Sheath material
A: SUS347, SUS310S, SUS316 B: Inconel
Sheath thermocouple response characteristic
100
80 φ6.4mm φ4.8mm Response (%) 60 φ3.2mm φ1.6mm 40 Type of thermocouple φ6.4 Sheath thermocouple Ordinary type φ4.8 φ3.2 φ1.6 (Grounding type: 20 to 100˚C in water) 0 0 2 4 6 8 Time (sec) 10 12 14 φ12 Time constant (sec) 2.60 1.22 0.53 0.11 51
20
2
Code symbols
12345678 9 10 11 12 13
Sheath type J thermocouple F T J Sheath type K thermocouple F T K Sheath type E thermocouple F T E 1 2 3 4 5 6 7 8 A B 1 2 3 4 W L R X
444Element Single-core Twin-core Single-core Twin-core Single-core Twin-core Single-core Twin-core Single-core Twin-core : insulation type, : insulation type, : grounding type, : grounding type, : insulation type, : insulation type, : grounding type, : grounding type, : insulation type, : insulation type, class 2 class 2 class 2 class 2 class 3 class 3 class 3 class 3 class 1 class 1 Description
FTJ cannot be used.
Sheath outside diameter (mm) φ1.6 φ3.2 φ4.8 φ6.4 Sheath material SUS316 SUS347 SUS310S Inconel (Note) Combination of 4th, 5th and 6th codes is possible but is limited as shown in the following table. : Single-core element only : Single-core and twin-core External Type Material size FTJ SUS316 SUS310S SUS316 SUS347 Inconel SUS347 SUS316 φ1.6 φ3.2 φ4.8 φ6.4
FTK
FTE
0 1 2
Mounting method Without mounting fitting With mounting fitting R1/8 (PT1/8); sheath outside diameter φ6.4cannot be used. With mounting fitting R1/4 (PT1/4) Insertion length Enter insertion length in the unit of ''cm''. Example) 200mm / 020 1500mm / 150 Minimum length: 10cm, Maximum length: 900cm L D G P Q 0 1 3 Z Structure Extension cable type Exposed terminal type Terminal box type Connector type Extension cable (with connector) type Cable length None (12th code: D, G, P) 1m cable 3m cable (12th code: L, Q) Other
3
FTJ, K, E
Outline diagram (Unit: mm)
( Insertion diameter "d" can be selected from 1.6 , 3.2 , 4.8 , 6.4.)
74 L (as specified)
2×4
(82)
ød
1000
40
L (as specified)
Sheath thermocouple
ø7.5
Sheath thermocouple
Compensation lead wire
G3/8 (PF3/8)
J FT K E
J FT K E
16 27 38 4A 5B
16 27 38 4A 5B
1 2 3 4
W L R X
ø8
0 14 2
G0
1 2 3 4
W L R X
0 14 2
L1 3
L (as specified) 70
ød
54
L (as specified)
ød
Sheath thermocouple Connector
43
Sheath thermocouple
J FT K E
J FT K E
16 27 38 4A 5B
16 27 38 4A 5B
1 2 3 4
W L R X
0 14 2
P0
1 2 3 4
W L R X
0 14 2
D0
Compensation lead wire L (as specified) 40
H (as specified) Sheath thermocouple 70
ø17
ø6
Connector
Connection diagram
Mounting fitting (Supplied as specified)
A(+)
J FT K E
16 27 38 4A 5B
1 2 3 4
W L R X
0 14 2
Q1 3
B(-)
R1/8 (PT1/8) or R1/4 (PT1/4)
Caution on Safety *Before using this product, be sure to read its instruction manual in advance.
Head Office
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng
Instrumentation Div. International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http://www.fic-net.jp/eng
Information in this catalog is subject to change without notice.
2×4
ød
ø8
Printed in Japan
ø17
ø6
ød