0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BB-XP

BB-XP

  • 厂商:

    GAMEWELL-FCI

  • 封装:

  • 描述:

    BB-XP - Six-Zone Addressable Interface Module - Gamewell-FCI by Honeywell

  • 数据手册
  • 价格&库存
BB-XP 数据手册
CZM-SS Features • Six addressable Class B or three addressable Class A initiating device circuits. • Removable 12 AWG (3.1 mm²) to 18 AWG (0.78 mm²) plug-in terminal blocks. • Status indicators for each point. • Unused addresses may be disabled. • Rotary address switches. • Compatible with Gamewell’s 602, 610, 632, 654 and 658 FACPs with SmartScan™ SLC. • Mount one or two modules in a BB-XP cabinet (optional). • Mount up to six modules on a CHS-6 chassis in a BB-25 cabinet (optional). • Mounting hardware included. Six-Zone Addressable Interface Module Description Gamewell’s CZM-SS SmartScanTM six-zone interface module p rovides an interface between the intelligent alarm system and a twowire conventional detection zone. A common SLC input is used for all modules, and the initiating device circuits share a common external supervisory supply and ground. Otherwise, each module operates independently from the others. The first module is addressed from 01 to 94 while the remaining modules are automatically assigned to the next five higher addresses. Provisions are included for disabling a maximum of two unused modules. All two-wire detectors being monitored must be two-wire UL compatibility listed with the modules. The CZM-SS transmits the status of a zone of two-wire detectors to the fire alarm control panel. Status conditions are reported as normal, open, or alarm. The interface module supervises the zone of detectors and the connection of the external power supply. Each CZM-SS module has panel-controlled bicolor LED indicators. The panel can cause the LEDs to blink, latch on, or latch off. Listings Listings and approvals below apply to the CZM-SS Six-Zone Addressable Interface Module. In some cases, the module may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: file S521. • CSFM approved: file 7300-1288:169. • MEA approved: file 368-01-E Vol.II. Product Line Information CZM-SS: Six-zone conventional-detector interface module. BB-XP: Optional cabinet for one or two modules. Dimensions, DOOR: 9.234" (23.454 cm) wide (9.484" [24.089 cm] including hinges), x 12.218" (31.0337 cm) high, x 0.672" (1.7068 cm) deep; BACKBOX: 9.0" (22.860 cm) wide (9.25" [23.495 cm] including hinges), x 12.0" (30.480 cm) high x 2.75" (6.985 cm); CHASSIS (installed): 7.150" (18.161 cm) wide overall x 7.312" (18.5725 cm) high interior overall x 2.156" (5.4762 cm) deep overall. BB-25: Optional cabinet for up to six modules mounted on CHS-6 chassis (below). Dimensions, DOOR: 24.0" (60.96 cm) wide x 12.632" (32.0852 cm) high, x 1.25" (3.175 cm) deep, hinged at bottom; BACKBOX: 24.0" (60.96 cm) wide x 12.550" (31.877 cm) high x 5.218" (13.2537 cm) deep. CHS-6: Chassis, mounts up to six modules in a BB-25 cabinet. CZM-SS CS-2470 09/01/06 Page 1 of 4 Specifications Standby current 2.0 mA (SLC current draw with all addresses used; if some addresses are disabled, the standby current decreases). Alarm current 40 mA (assumes all six LEDs solid ON). Temperature range 32°F to 120°F (0°C to 49°C). Humidity 10% to 85% noncondensing. Dimensions 6.8" (172.72 mm) high x 5.8" (147.32 mm) wide x 1.25" (31.75 mm) deep. Shipping weight 1.1 lb. (0.499 kg) including packaging. Mounting options CHS-6 chassis, BB-25 cabinet, or BB-XP cabinet. Wire gauge 12 AWG (3.1 mm²) to 18 AWG (0.78 mm²). CZM-SS is shipped in Class B position. Remove shunt for Class A operation. External supply voltage DC voltage: 18 – 28 volts power-limited (19 – 28 VDC when used with MTL isolator, model MTL 3043, in intrinsically safe applications). Ripple voltage: 0.1 VRMS maximum. External supply current: 90 mA maximum per address in alarm. In Class B operation, 540 mA maximum for all six addresses in alarm. In Class A operation, 270 mA maximum for all three addresses in alarm. Compatible detectors Contact Gamewell. Wiring Diagrams FIGURE 1: Interface Two-Wire Conventional Detectors — Class B, Style B NOTE: To use a common power supply between multiple CZM-SS modules, connect a long power supply jumper from T5 (or T6) to T5 (or T6) on the adjacent CZM-SS module. g2470w1.wmf Page 2 of 4 CZM-SS CS-2470 09/01/06 FIGURE 2: Interface Two-Wire Conventional Detectors — Class A, Style D NOTES: 1) To select Class A, remove the two shunts from the "A/B Select" positions. 2) To use a common power supply between multiple CZM-SS modules, connect a long power supply jumper from T5 (or T6) to T5 (or T6) on the adjacent CZM-SS module. g2470w2.wmf CZM-SS CS-2470 09/01/06 Page 3 of 4 Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 Phone: 203-484-7161 Fax: 203-484-7118 www.gamewell-fci.com A Honeywell Company © 2006 Gamewell-FCI Specifications and wiring information are provided for information only and are believed to be accurate. Gamewell-FCI assumes no responsibility for their use. Data and design are subject to change without notice. Installation and wiring instructions shipped with the product shall always be used for actual installation. For more information, contact Gamewell-FCI. Page 4 of 4 CZM-SS CS-2470 09/01/06
BB-XP 价格&库存

很抱歉,暂时无法提供与“BB-XP”相匹配的价格&库存,您可以联系我们找货

免费人工找货