0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
VSYS7

VSYS7

  • 厂商:

    GAMEWELL-FCI

  • 封装:

  • 描述:

    VSYS7 - Emergency Voice Evacuation - Gamewell-FCI by Honeywell

  • 数据手册
  • 价格&库存
VSYS7 数据手册
Emergency Voice Evacuation VSYS Options for IF610 Analog Addressable Control Panel Description The 610VE panel’s VSYS option adds emergency voice evacuation capabilities to the IdentiFlex 610 (IF610) analog addressable Fire Alarm Control Panel (FACP). The VSYS options are integrated in the same housing as the IF610, delivering dependable performance in an attractive cabinet design. VSYS systems provide prerecorded digital alert messages, all-call, and individual control-by-circuit (microphone). The emergency voice evacuation capability of the IF610 is used to provide prerecorded natural-voice messages (VEX) and emergency paging to facilitate orderly evacuation of protected areas. Voice evacuation systems are frequently required by the Authority Having Jurisdiction (AHJ) for areas of assembly such as auditoriums, gymnasiums, places of worship, and large meeting rooms. IF610/VSYS systems are suited to meet these needs and the requirements of NFPA 101 for New and Existing Assembly Occupancies. g2002ph1.jpg Features • Integrated voice in IF610 cabinet. • 25, 50, 100, or 200-watt systems. • 25-volt or 70-volt operation. • Fully supervised amplifier. • Multiple EVAC tones. • Four-minute message capacity. • Digital prerecorded voice evacuation messages. • Paging microphone with override. • All-call function. • Single or multiple speaker circuits (up to eight Class A or eight Class B maximum). Listings Listings and approvals below apply to the basic VSYS/VEX components. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: file S521. • CSFM approved: files 71651288:154, 7170-1288:153. • MEA approved: file 149-99-E Vol. II. Systems are available in 25, 50, 100, and 200-watt configurations. The IF610 with VSYS option can be configured for one to eight speaker circuits at up to 25 watts per circuit. Each amplifier offers an independent power supply and battery charger with a digital message repeater (VEX). System Operation The VSYS option is a flexible voice solution that can be sized to meet the job requirements by selecting the style and number of speaker circuits and the size of the amplifier. The system is also available with prerecorded digital message, and includes emergency paging capability. The VSYS includes a three-minute message restart, which occurs automatically after a three-minute depression of the microphone key when the digital messaging option is used. The VSYS Emergency Voice Evacuation System may also be ordered with multiple speaker-circuit configurations. Circuit-splitter modules allow the amplifier power to be divided among multiple zones for efficient use and controlled zone signaling. Splitter modules are equipped with circuit-select switches that allow for manual selection of voice evacuation zones for emergency paging. An LED is provided for annunciation of each zone’s status. Enclosures can house up to 200 watts of amplification, a paging microphone, digital voice messaging, and one or two circuit-splitter modules for up to eight Class B (Style Y) or up to four Class A (Style Z) circuits. Circuits are rated at 25 watts each. VSYS provides an integral battery charger for its dedicated batteries. Supervised remote microphones are supported by the system. Speaker circuits are controlled by individual toggle switches. A circuit identification label is provided for field-customized circuit labeling. VSYS for IF610 CS-2002 09/01/06 Page 1 of 2 Ordering Information VSYS1 IF610-126VE includes main CPU board, display board, keypad, single-loop card, and 6 A power supply; plus VEX25 voice system mounted in the cabinet. IF610-126VE includes main CPU board, display board, keypad, single-loop card, and 6 A power supply; plus VEX25-4B voice system mounted in the cabinet. IF610-126VE includes main CPU board, display board, keypad, single-loop card, and 6 A power supply; plus VEX50 voice system mounted in the cabinet. IF610-126VE includes main CPU board, display board, keypad, single-loop card, and 6 A power supply; plus VEX50-4B voice system mounted in the cabinet. IF610-252VE includes main CPU board, display board, keypad, twoloop card, and 6 A power supply; plus VEX50-4B voice system mounted in the cabinet. IF610-126VE includes main CPU board, display board, keypad, single-loop card, and 6 A power supply; plus VEX100-4B voice system mounted in the cabinet. IF610-252VE includes main CPU board, display board, keypad, twoloop card, and 6 A power supply; plus VEX100-4B voice system mounted in the cabinet. IF610-126VE includes main CPU board, display board, keypad, single-loop card, and 6 A power supply; plus VEX200-8B voice system mounted in the cabinet. IF610-252VE includes main CPU board, display board, keypad, twoloop card, and 6 A power supply; plus VEX200-8B voice system mounted in the cabinet. IF610-126VE includes main CPU board, display board, keypad, single-loop card, and 6 A power supply; plus VEX25-2A Class A voice system mounted in the cabinet. IF610-126VE includes main CPU board, display board, keypad, single-loop card, and 6 A power supply; plus VEX50-4A Class A voice system mounted in the cabinet. IF610-252VE includes main CPU board, display board, keypad, twoloop card, and 6 A power supply; plus VEX100-4A Class A voice system mounted in the cabinet. IF610-252VE includes main CPU board, display board, keypad, twoloop card, and 6 A power supply; plus VEX200-8A Class A voice system mounted in the cabinet. IF610-504VE includes main CPU board, display board, keypad, fourloop card, and 6 A power supply; plus VEX100-4B voice system mounted in the cabinet. IF610-504VE includes main CPU board, display board, keypad, fourloop card, and 6 A power supply; plus VEX200-8B voice system mounted in the cabinet. Specifications Voice evacuation system Input power 25 watt, 50 watt: 120 VAC, 0.80 A. 100 watt: 120 VAC, 0.60 A. 200 watt: 120 VAC, 1.20 A. Current 25 watt: 0.18 A standby, 1.00 A alarm. 50 watt: 0.13 A standby, 1.00 A alarm. 100 watt: 0.18 A standby, 2.50 A alarm. 200 watt: 0.36 A standby, 5.00 A alarm. Battery charging capabilities 25 watt, 50 watt: up to 18 AH. 100 watt: up to 24 AH. 200 watt: up to 48 AH. VSYS2 VSYS3 VSYS4 VSYS5 VSYS6 VSYS7 VSYS8 VSYS9 VSYS10 VSYS11 VSYS12 Separate sources of 120 VAC input power and 24 VDC battery backup power are used for the Fire Alarm Control Unit and the Voice Evacuation system. AC power source requirements are determined by adding the amperage requirements of the two systems together. Independent battery backup calculations must be completed for the Fire Alarm Control Unit and the Voice Evacuation system. Dimensions Cabinet: 30.0" H x 22.0" W x 5.5" D (cm: 76.2 H x 55.88 W x 13.97 D) for all VSYS options. Battery storage: 6.5" H x 22.0" W x 4.5" D (cm: 16.51 H x 55.88 W x 11.43 D). Relative humidity 93% noncondensing. Temperature rating VSYS14 VSYS15 VSYS16 Gamewell-FCI 12 Clintonville Road Northford, CT 06472 Phone: 203-484-7161 Fax: 203-484-7118 www.gamewell-fci.com A Honeywell Company © 2006 Gamewell-FCI 32°F – 120°F (0°C – 49°C). Specifications and wiring information are provided for information only and are believed to be accurate. Gamewell-FCI assumes no responsibility for their use. Data and design are subject to change without notice. Installation and wiring instructions shipped with the product shall always be used for actual installation. For more information, contact Gamewell-FCI. Page 2 of 2 VSYS for IF610 CS-2002 09/01/06
VSYS7 价格&库存

很抱歉,暂时无法提供与“VSYS7”相匹配的价格&库存,您可以联系我们找货

免费人工找货