0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SR2C-B4

SR2C-B4

  • 厂商:

    HONEYWELL(霍尼韦尔)

  • 封装:

    -

  • 描述:

    SOLID STATE SENSOR

  • 数据手册
  • 价格&库存
SR2C-B4 数据手册
Installation Instructions for the SR2 Series Hall-Effect Position Sensors ELECTRICAL AND MAGNETIC SPECIFICATIONS Supply Voltage, VDC Supply Current, mA max. Output Type Output Voltage, max. Output Current, mA max. Magnetic Type* Max. Op. -40 to 100°C +25°C Min. Rel. Min. Diff. Typ. Op. 4.5 to 24 VDC Circuit -1.0 to +25 VDC -0.5 V max. (ON or OFF) +25 V max. (OFF only) 40 mA -40 to +100°C (-40 to +212°F) Magnetic Flux No limit. Circuit cannot be damaged by magnetic overdrive. * Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device. However, the electrical and magnetic characteristics are not guaranteed as the maximum limits (above recommended operating conditions) are approached, nor will the device necessarily operate at absolute maximum rating. LEADWIRE COLOR CODE Vs (+) Ground (-) Output (Digital) NOTICE Do not reverse supply voltage polarity. Do not exceed maximum ratings. Sensing and Control MOUNTING DIMENSIONS (for reference only) 50 8 150 ABSOLUTE MAXIMUM RATINGS* Red Black White PK 88581 SR2C-B4 4.5 to 24 10 NPN 0.40 V 40 Unipolar 220 Typ. Rel. 80 Typ. Diff. 10 * A unipolar sensor has a plus maximum operate point and a plus minimum release point. One magnetic pole (south) is required to operate and release a unipolar sensor. Parameters Supply Voltage (Vs) Voltage Externally Applied to Output Output Current Temperature, Operate and Storage ISSUE 2 1SR15 Mounting Bracket SR2 Series PK 88581 TROUBLESHOOTING If sensor does not operate, follow these steps: 1. Make certain wiring is correct (load must be connected). 2. Measure supply voltage across the Red (+) and Black (-) leads to verify that proper supply voltage is present. 3. Connect positive lead of voltmeter to White (output) lead, and negative voltmeter lead to Black (-) lead. With magnet removed (or north pole present), the reading should equal Vs. 4. When the magnet (south pole) moves toward sensor face (beyond operating point), the sensor output should be 0.40 VDC. CURRENT SINKING OUTPUTS (Current flow through load into sensor.) Output terminal is open collector. In the unoperated condition (IL = 0), the output voltage is normally high. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Commencing with date of shipment, Honeywell’s warranty runs for 18 months. If warranted goods are returned to Honeywell during that period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact a nearby sales office. Or call: 1-800-537-6945 USA 1-416-293-8111 Canada 1-815-235-6847 International http://www.honeywell.sensing.com info.sc@honeywell.com Specifications not affecting form, fit or function may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. While we provide application assistance, personally and through our literature, it is up to the customer to determine the suitability of the product in the application. Sensing and Control Honeywell 11 West Spring Street Freeport, Illinois 61032 Printed with Soy Ink on 50% Recycled Paper PK 88581-2 0303 Printed in USA www.honeywell.com/sensing
SR2C-B4 价格&库存

很抱歉,暂时无法提供与“SR2C-B4”相匹配的价格&库存,您可以联系我们找货

免费人工找货
SR2C-B4
    •  国内价格
    • 1+2230.72375
    • 2+2186.98407
    • 3+2143.24439
    • 6+1985.78153

    库存:0

    SR2C-B4
      •  国内价格
      • 1+1578.17807
      • 2+1548.91785
      • 3+1519.66971
      • 6+1490.50622

      库存:0